Submitted:
22 August 2024
Posted:
23 August 2024
You are already at the latest version
Abstract
Keywords:
1. Introduction
2. Materials and Methods
3. Results




4. Discussion
5. Conclusions
Author Contributions
Funding
Institutional Review Board Statement
Informed Consent Statement
Data Availability Statement
Conflicts of Interest
References
- Joiner, A. Tooth Colour: A Review of the Literature. J Dent 2004, 32, 3–12. [Google Scholar] [CrossRef]
- Jahangiri, L.; Reinhardt, S.B.; Mehra, R. V.; Matheson, P.B. Relationship between Tooth Shade Value and Skin Color: An Observational Study. J Prosthet Dent 2002, 87, 149–152. [Google Scholar] [CrossRef]
- Joiner, A. Tooth Colour: A Review of the Literature. J Dent 2004, 32 Suppl. S1, 3–12. [Google Scholar] [CrossRef] [PubMed]
- Kim, H.-K. Evaluation of the Repeatability and Matching Accuracy between Two Identical Intraoral Spectrophotometers: An in Vivo and in Vitro Study. J Adv Prosthodont 2018, 10, 252–258. [Google Scholar] [CrossRef] [PubMed]
- El Mourad, A.M.; Al Shamrani, A.; Al Mohaimeed, M.; Al Sougi, S.; Al Ghanem, S.; Al Manie, W. Self-Perception of Dental Esthetics among Dental Students at King Saud University and Their Desired Treatment. Int J Dent 2021, 2021, 1–8. [Google Scholar] [CrossRef]
- Bosch, J.J. ten; Coops, J.C. Tooth Color and Reflectance as Related to Light Scattering and Enamel Hardness. J Dent Res 1995. [Google Scholar] [CrossRef]
- Menezes, R.P. de; Silva, P.D.; Leal, P.C.; Faria-e-Silva, A.L. Impact of 35% Hydrogen Peroxide on Color and Translucency Changes in Enamel and Dentin. Braz Dent J 2018, 29, 88–92. [Google Scholar] [CrossRef] [PubMed]
- He, W.; Park, C.J.; Byun, S.; Tan, D.; Lin, C.Y.; Chee, W. Evaluating the Relationship between Tooth Color and Enamel Thickness, Using Twin Flash Photography, Cross-polarization Photography, and Spectrophotometer. Journal of Esthetic and Restorative Dentistry 2020, 32, 91–101. [Google Scholar] [CrossRef]
- Spitznagel, F.A.; Boldt, J.; Gierthmuehlen, P.C. CAD/CAM Ceramic Restorative Materials for Natural Teeth. J Dent Res 2018, 97, 1082–1091. [Google Scholar] [CrossRef]
- Chaiyabutr, Y.; Kois, J.C.; Lebeau, D.; Nunokawa, G. Effect of Abutment Tooth Color, Cement Color, and Ceramic Thickness on the Resulting Optical Color of a CAD/CAM Glass-Ceramic Lithium Disilicate-Reinforced Crown. J Prosthet Dent 2011, 105, 83–90. [Google Scholar] [CrossRef]
- Wingo, K. A Review of Dental Cements. J Vet Dent 2018, 35, 18–27. [Google Scholar] [CrossRef] [PubMed]
- Archegas, L.R.P.; Freire, A.; Vieira, S.; Caldas, D.B. de M.; Souza, E.M. Colour Stability and Opacity of Resin Cements and Flowable Composites for Ceramic Veneer Luting after Accelerated Ageing. J Dent 2011, 39, 804–810. [Google Scholar] [CrossRef]
- Chang, J.; Da Silva, J.D.; Sakai, M.; Kristiansen, J.; Ishikawa-Nagai, S. The Optical Effect of Composite Luting Cement on All Ceramic Crowns. J Dent 2009, 37, 937–943. [Google Scholar] [CrossRef] [PubMed]
- Liberato, W.F.; Barreto, I.C.; Costa, P.P.; de Almeida, C.C.; Pimentel, W.; Tiossi, R. A Comparison between Visual, Intraoral Scanner, and Spectrophotometer Shade Matching: A Clinical Study. J Prosthet Dent 2019, 121, 271–275. [Google Scholar] [CrossRef]
- Edelhoff, D.; Beuer, F.; Schweiger, J.; Brix, O.; Stimmelmayr, M.; Guth, J.-F. CAD/CAM-Generated High-Density Polymer Restorations for the Pretreatment of Complex Cases: A Case Report. Quintessence Int 2012, 43, 457–467. [Google Scholar] [PubMed]
- Pietrobon, N.; Lehner, C.R.; Schärer, P. [Long-Term Temporary Dentures in Crown and Bridge Prosthesis. The Design Principles, Choice of Material and Practical Procedure]. Schweiz Monatsschr Zahnmed 1996, 106, 236–247. [Google Scholar] [PubMed]
- LeSage, B.P. CAD/CAM: Applications for Transitional Bonding to Restore Occlusal Vertical Dimension. J Esthet Restor Dent 2020, 32, 132–140. [Google Scholar] [CrossRef]
- Burian, G.; Erdelt, K.; Schweiger, J.; Keul, C.; Edelhoff, D.; Güth, J.-F. In-Vivo-Wear in Composite and Ceramic Full Mouth Rehabilitations over 3 Years. Sci Rep 2021, 11, 14056. [Google Scholar] [CrossRef]
- Paravina, R.D.; Ghinea, R.; Herrera, L.J.; Bona, A.D.; Igiel, C.; Linninger, M.; Sakai, M.; Takahashi, H.; Tashkandi, E.; Mar Perez, M. del Color Difference Thresholds in Dentistry. Journal of Esthetic and Restorative Dentistry 2015, 27, S1–S9. [Google Scholar] [CrossRef]
- Sampaio, C.S.; Belfus, J.; Avila, A.; Cordero, C.; Freitte, M.; Ferrari, V.; Atria, P.J.; Jorquera, G. Effect of Different Fabrication Steps on Color and Translucency of a CAD-CAM Feldspathic Ceramic. Journal of Esthetic and Restorative Dentistry 2021, 33, 1038–1044. [Google Scholar] [CrossRef]
- Gomes, C.; Martins, F.; Reis, J.A.; Maurício, P.D.; Ramírez-Fernández, M.P. Color Assessment of Feldspathic Ceramic with Two Different Thicknesses, Using Multiple Polymeric Cements. Polymers (Basel) 2023, 15, 397. [Google Scholar] [CrossRef] [PubMed]
- Pereira, J.S. de C.; Reis, J.A.; Martins, F.; Maurício, P.; Fuentes, M.V. The Effect of Feldspathic Thickness on Fluorescence of a Variety of Resin Cements and Flowable Composites. Applied Sciences 2022, 12, 6535. [Google Scholar] [CrossRef]
- Carrabba, M.; Vichi, A.; Tozzi, G.; Louca, C.; Ferrari, M. Cement Opacity and Color as Influencing Factors on the Final Shade of Metal-free Ceramic Restorations. Journal of Esthetic and Restorative Dentistry 2020, 34, 423–429. [Google Scholar] [CrossRef]
- Bayindir, F.; Koseoglu, M. The Effect of Restoration Thickness and Resin Cement Shade on the Color and Translucency of a High-Translucency Monolithic Zirconia. J Prosthet Dent 2020, 123, 149–154. [Google Scholar] [CrossRef]
- Alayad, A.S.; Alqhatani, A.; Alkatheeri, M.S.; Alshehri, M.; AlQahtani, M.A.; Osseil, A.E. Bin; Almusallam, R.A. Effects of CAD/CAM Ceramics and Thicknesses on Translucency and Color Masking of Substrates. Saudi Dent J 2021, 33, 761–768. [Google Scholar] [CrossRef] [PubMed]
- Araujo, E.; Perdigão, J. Anterior Veneer Restorations - An Evidence-Based Minimal-Intervention Perspective. J Adhes Dent 2021, 23, 91–110. [Google Scholar] [CrossRef] [PubMed]
- Joiner, A.; Luo, W. Tooth Colour and Whiteness: A Review. J Dent 2017, 67, S3–S10. [Google Scholar] [CrossRef]
- Günal-Abduljalil, B.; Ulusoy, M.M. The Effect of Resin Cement Shade and Restorative Material Type and Thickness on the Final Color of Resin-Matrix Ceramics. J Prosthodont Res 2022, 66, JPR_D_20_00138. [Google Scholar] [CrossRef]
- Matos, J.D.M. de; Nakano, L.J.N.; Bottino, M.A.; Jesus, R.H. de; Maciel, L.C. Current Considerations for Dental Ceramics and Their Respective Union Systems. Rev Bras Odontol 2020, 77, 1. [Google Scholar] [CrossRef]
- Comba, A.; Paolone, G.; Baldi, A.; Vichi, A.; Goracci, C.; Bertozzi, G.; Scotti, N. Effects of Substrate and Cement Shade on the Translucency and Color of CAD/CAM Lithium-Disilicate and Zirconia Ceramic Materials. Polymers (Basel) 2022, 14, 1778. [Google Scholar] [CrossRef]
- Dede, D.Ö.; Ceylan, G.; Yilmaz, B. Effect of Brand and Shade of Resin Cements on the Final Color of Lithium Disilicate Ceramic. J Prosthet Dent 2017, 117, 539–544. [Google Scholar] [CrossRef]
- Șoim, A.; Strîmbu, M.; Burde, A. V.; Culic, B.; Dudea, D.; Gasparik, C. Translucency and Masking Properties of Two Ceramic Materials for Heat-Press Technology. Journal of Esthetic and Restorative Dentistry 2018, 30, E18–E23. [Google Scholar] [CrossRef] [PubMed]
- Sonza, Q.N.; Della Bona, A.; Pecho, O.E.; Borba, M. Effect of Substrate and Cement on the Final Color of Zirconia-Based All-Ceramic Crowns. J Esthet Restor Dent 2021, 33, 891–898. [Google Scholar] [CrossRef] [PubMed]
- Pires, L.A.; Novais, P.M.R.; Araújo, V.D.; Pegoraro, L.F. Effects of the Type and Thickness of Ceramic, Substrate, and Cement on the Optical Color of a Lithium Disilicate Ceramic. Journal of Prosthetic Dentistry 2017, 117, 144–149. [Google Scholar] [CrossRef]
- Niu, E.; Agustin, M.; Douglas, R.D. Color Match of Machinable Lithium Disilicate Ceramics: Effects of Cement Color and Thickness. Journal of Prosthetic Dentistry 2014, 111, 42–50. [Google Scholar] [CrossRef] [PubMed]
- Hensel, F.; Koenig, A.; Doerfler, H.-M.; Fuchs, F.; Rosentritt, M.; Hahnel, S. CAD/CAM Resin-Based Composites for Use in Long-Term Temporary Fixed Dental Prostheses. Polymers (Basel) 2021, 13, 3469. [Google Scholar] [CrossRef] [PubMed]
- Klapdohr, S.; Moszner, N. New Inorganic Components for Dental Filling Composites. Monatshefte f�r Chemie - Chemical Monthly 2005, 136, 21–45. [Google Scholar] [CrossRef]
- Lim, Y.-K.; Lee, Y.-K.; Lim, B.-S.; Rhee, S.-H.; Yang, H.-C. Influence of Filler Distribution on the Color Parameters of Experimental Resin Composites. Dental Materials 2008, 24, 67–73. [Google Scholar] [CrossRef]
- Pecho, O.E.; Pérez, M.M.; Ghinea, R.; Della Bona, A. Lightness, Chroma and Hue Differences on Visual Shade Matching. Dental Materials 2016, 32, 1362–1373. [Google Scholar] [CrossRef]
- Pop-Ciutrila, I.-S.; Ghinea, R.; Colosi, H.A.; Ruiz-López, J.; Perez, M.M.; Paravina, R.D.; Dudea, D. Color Compatibility between Dental Structures and Three Different Types of Ceramic Systems. BMC Oral Health 2021, 21, 75. [Google Scholar] [CrossRef]
| Material and Manufacturer | Composition | Batch Number |
|---|---|---|
| Telio® CAD (Ivoclar Vivadent. Schaan, Liechtenstein) LT BL3 A1 |
>98% ester-based cross-linked polymethyl methacrylate, <0,1% pigments | Z04CK9 |
| VITA CAD-Temp® (VITA Zahnfabrik, Bad Säckingen, Germany) 1 M2T A1 |
83-86% poly-methyl methacrylate (PMMA); 14% SiO2; <0,1% pigments | 95850 |
| FiltekTM Supreme XTE Universal Restorative Body Shade A2 (3M ESPE, Minnesota, USA) | UDMA, TEGMA, Bis-GMA, Bis- EMA, silica (20nm), Zirconia, pigments. (4- 11nm). Average particle size 0,6 to 10 μm. Inorganic particles represent 78,5% of the total charge. | NF22572 |
| FiltekTM Supreme XTE Universal Restaurative Body Shade A3 (3M ESPE, Minnesota, USA) | UDMA, TEGMA, Bis-GMA, Bis- EMA, silica (20nm), Zirconia, pigments. (4- 11nm). Average particle size 0,6 to 10 μm. Inorganic particles represent 78,5% of the total charge. | N927242 |
| Thicknesses | |||||
|---|---|---|---|---|---|
| Bases | Material | 0,5mm | 1mm | 2mm | |
| A2 | Telio CAD A2 | 4,30 ± 0,16 | 8,00 ± 0,25 | 8,88 ± 0,37 | p<0,001 (a)(*) |
| Vita CAD-Temp A2 | 2,00 ± 0,32 | 5,17 ± 0,19 | 5,76 ± 0,22 | p<0,001 (a)(*) | |
| A3 | Telio CAD A2 | 7,45 ± 0,29 | 11,36 ± 0,28 | 12,69 ± 0,30 | p<0,001 (a)(*) |
| Vita CAD-Temp A2 | 3,06 ± 0,36 | 5,90 ± 0,20 | 5,51 ± 0,21 | p<0,001 (a)(*) | |
| p<0,001 (a)(*) | p<0,001 (a)(*) | p<0,001 (a)(*) | |||
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).