Abstract
Keywords:
1. Introduction
2. Energy and Exergy Analysis of Thermal Systems
2.1. Energy Conservation
2.2. Exergy-Balance Equation and the Second Law of Thermodynamics
2.3. Exergy Cost-Balance Equation
3. Hydrogen-Fueled 1-kW PEMFC System
3.1. Energy Conservation and Exergy-Balance and Exergy Cost-Balance Equations for PEMFC System
3.2. Energy Conservation and Exergy-Balance of FCS
3.3. Exergy Cost-Balance Equation for Overall System
4. Calculation Results and Discussion
5. Conclusions
Acknowledgments
Appendix
References
- Gigliucci G, Petruzzi L, Cerelli E, Garzisi A, La Mendola A, Demonstration of a residential CHP system based on PEM fuel cells, J Power Sources 2004; 131: 62-68. [CrossRef]
- Chen JC, Chen XH, Chen LW, Guo JC. An available method exploiting the waste heat in a proton exchange membrane fuel cell system. Int J Hydrogen Energy 2011; 36: 6099-104.
- Hwang JJ, Zou ML, Chang WR, Su A, Weng FB, Wu W. Implementation of a heat recovery unit in a proton exchange membrane fuel cell system. Int J Hydrogen Energy 2010; 35: 8644-53.
- Barelli L, Bidini G, Gallorini F, Ottaviano, An exergetic-exergetic analysis of a residential CHP system based on PEM fuel cell. Appl Energy 2011; 88: 4334-4342.
- Chen X, Gong G, Wan Z, Luo L, Wan J. Performance analysis of 5 kW PEMFC based residential micro-CCHP with absorption chiller. Int J Hydrogen Energy 2015; 40: 10647-57.
- Seo, S.-H., Oh, S.-D., Kwak, H., Thermodynamic, exergetic and thermoeconomic analyses of double-effect LiBr-water absorption refrigeration systems with a 5 kW high temperature PEMFC as heat source for data center applicaions. Energies 2022; 15:3101.
- Oh SD, Kim KY, Oh SB, Kwak H, Optimal operation of a 1-kW PEMFC-based CHP system for residential applications, Appl. Energy, 95, 93-101, 2012.
- Ebadi MJ, Gorji-Bandpy M, Exergetic analysis of gas turbine plants. Int J Exergy 2005; 2 : 31-39.
- Valero A, Lerch F, Serra L, Royo J. Structural theory and thermoeconomic diagnosis Part II: Application to an actual power plant. Energy Conversion and Management, 2002;43:1519-1535.
- Wang L, Fu P, Wang N, Morosuk T, Yang Y, Tsatsaronis G. Malfunction diagnosis of thermal power plants based on advanced exergy analysis: The case with multiple malfunctions occurring simultaneously, Energy Conver and Manage 2017; 144: 1453-1467.
- Oh HS, Lee Y, Kwak H. Diagnosis of combined cycle power plant based on thermoeconomic analysis: A computer simulation study. Entropy, 2017; 19: 643.
- Seo S.H., Oh S.-D., Oh H, Kim M, Lee WY, Kwak, H. Thermal management for a hydrogen-fueled 1-kW PEMFC based on thermoeconomic analysis. Int J Hydrogen Energy 2019; 44: 24934-24946.
- Piacentino A, Talamo M, Critical analysis of conventional thermoeconomicapproaches to the diagnosis of multiple faults in air conditioning units: Capabilities, drawbacks and improvement directions. A case studu for an air-cooled system with 120 kW capacity. Int. J. Refrigeration 2013; 36: 24-44.
- Yoo, Y., Oh, H.-S., Uysal, C., Kwak, H., Thermoeconomic diagnosis of an air-cooled air conditioning systems. Int. J. Exergy 2018, 26 393-417.
- Morosuk, T.; Tsatsaronis,G. A new approach to the exergy analysis of absorption refrigeration machines. Energy 2008, 33, 890-907.
- Kwak H, Kim DJ, Jeon JS. Exergetic and thermoeconomic analyses of power plant, Energy 2003; 28: 343-360.
- Bejan A. Advanced Engineering Thermodynamics, John Wiley and Sons, 1997.
- Oh S, Pang H, Kim S, Kwak H. Exergy analysis for a gas turbine cogeneration system, J Eng Gas Turbine and Power. 1996; 118: 782–791.
- Kotas J. The Exergy Method of Thermal Plant Analysis, Krieger; 1995.
- Moran, J. Availability Analysis: A Guide to Efficient Energy Use, Prentice Hall, Inc., Englewood Cliffs, 1982.
- Ye L, Du Q, Yin Y. Exergy analysis of high-temperture proton exchange membrane fuel cell systems. Int J Green Energy 2015; 12: 917-929.
- Müller EA, Stefanopoulou AG, Analysis, modeling, and validation for the thermal dynamics of a polymer electrolyte membrane fuel cell, Proceedings of Fuel Cell 2008, Third International Conference on Fuel Cell Science, Engineering and Technology, FUELCELL2005-74050, 2005.

| States | (kmol/h) | (kPa) | (K) | (kJ/h) | (kJ/h/K) | (kJ/h) |
|---|---|---|---|---|---|---|
| 101 | 0.0846 | 100.90 | 299.40 | 3.0821 | 0.471 | -1.186 |
| 102 | 0.0846 | 113.36 | 305.99 | 19.340 | 0.443 | 23.461 |
| 103 | 0.0846 | 105.40 | 322.14 | 59.280 | 0.621 | 10.214 |
| 104 | 0.0748 | 102.28 | 332.99 | 76.067 | 0.540 | 35.345 |
| 105 | 0.0748 | 102.42 | 312.52 | 31.335 | 0.407 | 30.376 |
| 206 | 0.0275 | 103.98 | 299.97 | 1.443 | 0.005 | 0.0 |
| 207 | 0.0079 | 102.05 | 326.10 | 6.368 | 0.020 | 0.002 |
| 508 | 4.8295 | 99.80 | 325.69 | 19136.736 | 64.053 | 435.754 |
| 509 | 4.8295 | 143.63 | 325.59 | 19103.614 | 63.940 | 436.496 |
| 510 | 4.8295 | 122.48 | 333.13 | 21846.193 | 72.273 | 694.585 |
| 511 | 4.8295 | 110.48 | 326.14 | 19301.256 | 64.555 | 450.631 |
| 512 | 2.2926 | 102.35 | 303.10 | 5185.052 | 17.998 | 7.057 |
| 513 | 2.2926 | 114.85 | 303.03 | 5173.442 | 17.958 | 7.378 |
| 514 | 2.2926 | 105.72 | 331.47 | 10082.861 | 33.445 | 299.545 |
| 515 | 2.2926 | 103.72 | 331.47 | 10082.791 | 33.445 | 299.463 |
| 516 | 2.2926 | 101.75 | 303.05 | 5176.401 | 17.970 | 6.891 |
| 518 | 2.2926 | 100.75 | 302.05 | 5003.788 | 17.400 | 4.340 |
| Enthalpy flow in |
Enthalpy flow out |
Work- flow | Heat flow | Irreversibility rate |
||
|---|---|---|---|---|---|---|
| Air blower | -3.082 | 19.340 | -16.258 | 0.0 | -8.389 | -8.389 |
| Anode | -1.443 | 6.368 | 0.0 | -4.925 | 4.648 | -0.277 |
| Cathode | -59.280 | 76.067 | 0.0 | -16.787 | -24.097 | - 40.884 |
| Humidifier | -95.408 | 90.615 | 0.0 | 4.793 | 13.484 | 18.277 |
| HTX for FCS | -19103.614 | 21486.193 | -2742.579 | 2484.490 | -258.089 | |
| HTXDI | -27019.635 | 29384.117 | 0.0 | -2364.482 | 2316.269 | -48.213 |
| DIWT | -19301.256 | 19136.736 | 164.521 | -149.644 | 14.877 | |
| Pump 1 | -19136.736 | 19103.614 | -5.503 | 38.625 | -33.864 | 4.762 |
| HTXWC | -10082.791 | 5176.401 | -18.000 | 4924.390 | -4613.819 | 310.572 |
| Hot WT | -5003.788 | 5185.052 | 0.0 | -181.264 | 178.548 | -2.716 |
| Pump 2 | -5185.052 | 5173.442 | -0.645 | 12.255 | -11.931 | 0.324 |
| Component | Net exergy flow rates (kJ/h) | Irreversibility | |||
|---|---|---|---|---|---|
| rate (kJ/h), | |||||
| Air blower | -16.258 | 0.0 | 0.244 | 24.403 | -8.389 |
| Anode | 0.0 | 0.0 | 1.622 | -1.620 | -0.002 |
| Cathode | 0.0 | 0.0 | 31.651 | -6.521 | -25.131 |
| Humidifier | 0.0 | 0.0 | -1.381 | -16.834 | 18.215 |
| HTX in FCS | 0.0 | 0.0 | 259.935 | -1.845 | -258.090 |
| FCS | 2923.596 | -5666.175 | (2642.475) | 0.0 | 100.104 |
| HTX DI | 49.638 | -1.425 | -48.213 | ||
| DIWT | 0.0 | 0.0 | -13.945 | -0.932 | 14.877 |
| Pump 1 | -5.503 | 0.0 | -3.083 | 3.824 | 4.762 |
| HTXWC | -18.0 | 0.0 | -292.490 | -0.082 | 310.572 |
| Hot WT | 2.650 | 0.066 | -2.716 | ||
| Pump 2 | -0.645 | -0.196 | 0.518 | 0.324 | |
| Total | 2883.19 | -5666.175 | (2677.12) | -0.448 | 106.313 |
| C1P | C2T | C3T | C4C | C5T | C6W | C7T | |
| -0.8955 | -230.52 | 102.99 | -86238.0 | -4.173 | 0.2703 | -3.9587 | |
| C8T | C9P | C10T | C11T | C12P | CT | CP | |
| 5.80 | 94.494 | -4.790 | 2.065 | 52.719 | 114.76 | 12.759 | |
| CC | CW | CS | |||||
| -86238.0 | 0.2703 | -4.483 | |||||
| Component | Electricity cost flow | Thermal exergy cost flow | Mechanical exergy cost flow | Lost cost flow | Invest cost flow |
Investment (USD) |
|---|---|---|---|---|---|---|
| Air blower | -0.004 | 0.028 | -0.022 | 0.038 | -0.039 | 1431.5 |
| Anode | 0.167 | -0.021 | -0.146 | 5332.4 | ||
| Cathode | -3.515* | 3.632 | -0.083 | 0.113 | -0.146 | 5332.4 |
| Humidifier | 0.318 | -0.215 | -0.082 | -0.022 | 800.0 | |
| HTX in FCS | -1.085 | -0.024 | 1.157 | -0.049 | 1775.3 | |
| FCS | 0.790 | -0.449 | -0.342 | 7856.6 | ||
| HTX DI | -0.197 | -0.018 | 0.216 | -0.001 | 52.2 | |
| DIWT | 0.081 | -0.012 | -0.067 | -0.002 | 84.2 | |
| Pump 1 | -0.001 | -0.354 | 0.361 | -0.001 | -0.005 | 168.4 |
| HTXWC | -0.005 | 1.401 | -0.001 | -1.392 | -0.003 | 111.1 |
| Pump 2 | -0.022 | 0.027 | -0.0 | -0.005 | 168.4 | |
| Hot WT | 0.005 | 0.001 | 0.012 | -0.018 | 673.7 | |
| Total | -2.735(0.78+) | 3.974 | -0.007 | -0.455 | -0.778 | 23786.2 |
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |