Thermodynamic Analysis of Integrated Advanced Compressed Air Energy Storage System with a Solar Heat Booster

A peer-reviewed version of this preprint was published in:
AppliedMath 2026, 6(7), 107. https://doi.org/10.3390/appliedmath6070107

Submitted:

23 April 2026

Posted:

23 April 2026

You are already at the latest version

Abstract
This study presents a thermodynamic analysis of an ideal integrated adiabatic compressed air energy storage (A-CAES) system with single-temperature thermal energy storage (TES) subjected to an external heat boost. The additional heat is assumed to be supplied by concentrated solar energy, although other heat sources, such as combustion, can also be used, at least in principle. We examine three principal performance metrics of the integrated A-CAES system: the round-trip coefficient of performance (CoP), the marginal thermal CoP of the solar booster, and the second-law efficiency of the overall integrated system. The principal thermodynamic constraint is formulated as a theorem for the upper bound of the integrated 2nd law efficiency. The analysis shows that the system can attain a high round-trip CoP while simultaneously utilising the external solar heat boost very efficiently. These results highlight the thermodynamic potential of integrating solar heat boosting with A-CAES to improve both storage performance and renewable heat utilisation.
Keywords: 
;  ;  ;  

1. Introduction

Energy storage is a critical enabler of the energy transition, allowing renewable generation to be decoupled from demand and offsetting the inherently intermittent character of wind and solar resources [1]. Advanced compressed air energy storage (A-CAES) systems store surplus electrical energy by compressing air into underground caverns while simultaneously capturing thermal energy in thermal energy storage (TES). During periods of high electricity demand, this stored energy is released through expansion to generate power [2]. Typically, the electrical round-trip coefficient of performance (CoP) of such systems lies in the range of 60%–70% and can, in some cases, exceed 70% [3,4]. To enhance system performance, a solar heat booster can be incorporated [5]. By coupling an external solar heat source with the TES, additional thermal energy is supplied to the cycle, which can increase the net work output and integrate energy storage with renewable generation. A thermodynamically similar effect may also be achieved using other suitable external heat sources.
To evaluate the thermodynamic effect of this solar heat integration, it is essential to examine how effectively the added heat is utilised. Specifically, for an infinitesimal increment of heat input δ Q , the corresponding increment of useful work δ W needs to be determined. While prior studies have primarily focused on overall round-trip CoP and system performance through simulations, a fundamental analytical framework for integrated A-CAES systems remains lacking.
In this study, we develop a mathematical formulation for an ideal integrated A-CAES cycle with the addition of solar heat. By combining first-law energy balances with cycle relationships, a closed-form algebraic expression is derived that connects the electrical round-trip CoP and the heat boost. The analysis also reveals the dependence of the marginal thermal CoP ( δ W / δ Q ) on the TES temperature. Finally, we evaluate the overall second-law efficiency of the system and show that it always remains below unity.
Table 1. Notation.
Table 1. Notation.
Notation Description
N Number of compression and expansion stages (assumed equal).
C p Specific heat at constant pressure.
k Adiabatic index, C p / C v .
P r Pressure ratio at each stage (assumed equal).
r p ( P r ) ( k − 1 ) / k .
W T Turbine work.
W C Compressor work.
δ Q Infinitesimal heat input.
η t Turbine isentropic efficiency.
η c Compressor isentropic efficiency.
E r Exergy recovered.
E s Exergy supplied.
COP th Marginal coefficient of performance.
CoP rt Electrical round-trip CoP.
η II Second-law efficiency. 1

2. Integrated A-CAES with a Solar Booster

As illustrated in Figure 1, the thermal energy generated during air compression is captured and stored in the thermal energy storage (TES), and is subsequently utilised for reheating prior to the expansion stage. To further improve system performance, a solar heat booster is integrated into the A-CAES system, supplying additional renewable thermal energy to the TES. This supplementary heat input can either offset or reduce the required compression work before expansion, thereby enhancing the overall round-trip CoP of the system.

2.1. Ideal Integrated CAES System with Single-Temperature TES

As illustrated in the T–S diagram in Figure 2, the introduction of a solar heat boost influences the performance of the integrated A-CAES system. In practice, CAES systems exhibit significant thermodynamic and operational complexity. In the present study, we adopt a set of simplifying assumptions and consider an idealised system configuration.
  • The number of compression and expansion stages is finite; therefore, the CAES system does not behave as an isothermal CAES system, which would require a very large number of stages.
  • There is perfect intercooling and heat recovery in the system; the compressor and turbine have real efficiencies below 100% isentropic efficiency.
  • Air behaves as an ideal gas.
  • Pressure ratios at each compression and expansion stage are equal.
  • The TES is represented as a single-temperature thermal energy store.
  • The analysis is carried out on a unit-mass basis; therefore, all work and heat terms are expressed as specific quantities.
  • Air is stored at atmospheric temperature T 0 .
  • The turbine outlet temperature cannot drop below the atmospheric temperature T 0 .
The blue lines indicate the compressor work, and the red lines indicate the turbine work. To produce turbine work, the TES supplies the thermal energy required for reheating the air. The TES, in turn, is charged by energy extracted from the compressed air during the compression stages. With the addition of a heat booster, two operating regimes need to be considered.

2.1.1. Regime 1: Solar-Assisted Energy Storage

In this regime, a limited amount of heat is supplied by the solar booster, as illustrated in Figure 2, where
T 4 = T 0 < T 2 < T TES < T 1 < T 3
Air is compressed through N stages, and during intermediate intercooling a portion of the thermal energy from the compressed air is transferred to the TES operating at T TES , while the remaining heat is rejected to the surroundings. Here, W c is the cumulative compression work and W t represents the total turbine work over all stages. Let h c 1 = C p ( T 1 − T TES ) represent the heat transferred to the TES from the first compression stage, and let h c = C p ( T 3 − T TES ) denote the heat transfer from the subsequent compression stages. Similarly, h t = C p ( T TES − T 0 ) represents the heat supplied by the TES for reheating the air in each expansion stage. The thermal energy stored in the TES is then used to reheat the air prior to expansion. With the introduction of the solar booster, the overall energy balance of the system can be expressed so that the total heat required for reheating equals the sum of the external heat input Q and the thermal energy accumulated in the TES during compression:
Q + ( N − 1 ) h c + h c 1 = N h t
This relation represents the total thermal energy necessary for one complete cycle of the integrated A-CAES system. In the absence of any external heat input, Q = 0 , the entire reheating requirement is met by the thermal energy supplied from the compression process. However, as the solar heat input Q increases, the energy transfer h c from the compression stages decreases, leading to a reduction in T 3 and T 2 (see Figure 2) and, therefore, a corresponding decrease in h c . This, in turn, lowers the required compressor work. The operational parameters of the turbine do not change. The upper bound for this regime is Q ≤ Q b , where the case Q = Q b is shown in Figure 3. This limit is reached when T 3 approaches its minimum value, equal to T 1 , so that
T 4 = T 0 = T 2 < T TES < T 1 = T 3
The thermal regimes for the compressor and turbine then become similar, and
Q b = N h t − N h c 1 = N C p ( T TES − T 0 ) − T 1 − T TES
In this limiting case, h c = h c 1 is achieved because T 2 = T 0 .

2.1.2. Regime 2: Energy Storage with Solar Co-Generation

In the second regime, illustrated in Figure 4, the operating conditions of the A-CAES system are such that Q > Q b , where Q b is defined in (4), and the solar heat dominates, implying that
T 0 = T 2 < T 4 < T TES < T 1 = T 3
This regime is termed regime 2a. As the external heat input Q increases further, the TES temperature and the corresponding turbine outlet temperature increase, as shown in Figure 4, leading to greater h t , while the compressor parameters do not change. The energy balance remains
Q = N h t − N h c 1 = C p N ( T TES − T 4 ) + T 4 − T 0 − N C p T 1 − T TES
with decreasing h c 1 until T TES = T 1 and h c 1 = 0 . In the subsequent regime,
T 0 = T 2 < T 4 < T 1 = T 3 < T TES
which is termed regime 2b as shown in Figure 5, the system increasingly operates as a heat engine. The heat balance for this case can be expressed as
Q = N h t = N C p ( T TES − T 4 ) + C p T 4 − T 0
As Q increases further, there is a corresponding increase in T TES and T 4 , leading to an increase in h t and turbine work output. The compressor work remains unchanged and minimal.

3. Thermodynamic Analysis

The performance of the energy storage system is characterised by the round-trip coefficient of performance
CoP rt = W t W c
which characterises work returned relative to work expended. Note that this Co P rt does not generally reflect the overall energy balance, since it deals with work only and does not take into account the “free” solar heat, although Co P rt depends on Q.
A small additional amount of solar heat δ Q supplied to the TES induces extra useful work δ W = δ ( W t − W c ) produced by the system. This introduces the second important CoP, namely the marginal thermal coefficient of performance
CoP th = δ W δ Q
which characterises the conversion of external heat into additional work.
The performances of the turbine and compressor are characterised by the corresponding isentropic efficiencies
η t = ( T TES − T 4 ) ( T TES − T 4 ′ ) , η c = ( T 1 ′ − T 0 ) ( T 1 − T 0 ) = ( T 3 ′ − T 2 ) ( T 3 − T 2 )
where the prime denotes the temperatures of the isentropic turbine and compressor operating with the same storage-to-environment pressure ratio P s / P 0 . We also use the following notation for the related temperature ratios:
r c = T 1 T 0 = T 3 T 2 = 1 + 1 η c r p − 1 , r t = T TES T 4 = 1 1 − η t 1 − 1 r p
where
r p N = P s P 0 k − 1 k
and r c ≥ r t . All these parameters are fixed by the characteristics of the turbine and compressor and by the pressure ratio.

3.1. Performance Coefficients in Regime 1

In this regime, the electrical round-trip CoP of the storage system is given by
CoP rt = N C p ( T TES − T 0 ) C p ( T 1 − T 0 ) + ( N − 1 ) C p ( T 3 − T 2 )
implying that
1 CoP rt ( 1 − 1 / r t ) ( 1 − 1 / r c ) = ( N − 1 ) N T 3 T TES + 1 N T 1 T TES
Using equation (2), the energy balance for the integrated heat-boosted CAES system is
Q + C p ( T 1 − T TES ) + ( N − 1 ) C p ( T 3 − T TES ) = N C p ( T TES − T 0 )
where
T TES T 0 = r t
since T 0 = T 4 in regime 1.
Dividing equation (16) by N C p T TES gives
Q N C p T TES + ( N − 1 ) N T 3 T TES + 1 N T 1 T TES = 2 − 1 r t
Substituting equation (15) into equation (18), we obtain
Q N C p T TES + 1 CoP rt ( 1 − 1 / r t ) ( 1 − 1 / r c ) + 1 r t = 2
resulting in the following value for Co P rt :
CoP rt = 2 − 1 r t − Q r t N C p T 0 − 1 ( 1 − 1 / r t ) ( 1 − 1 / r c )
In this regime, the useful work W = W t − W c increases through a reduction in W c as Q increases, while W t remains constant. Therefore,
W = W t − W c = W t 1 − 1 CoP rt ( Q )
Hence, using (20),
δ W δ Q = W t N C p T TES ( 1 − 1 / r c ) ( 1 − 1 / r t )
which, due to
W t = N C p T TES − T 0 = N C p T TES 1 − 1 r t
is transformed into
δ W δ Q = 1 − 1 r c

3.2. Performance Coefficients in Regime 2

In this regime, the round-trip Co P rt of the storage system is given by
CoP rt = T TES − T 4 T 1 − T 0 = T TES T 0 1 r c ( 1 − 1 / r t ) ( 1 − 1 / r c )
The energy balance takes the form
Q + N C p θ T 1 − T TES = N C p T TES − T 4 + C p T 4 − T 0
where the indicator θ is defined as
θ = 1 , T 1 > T TES , i . e . regime 2 a 0 , T 1 ≤ T TES , i . e . regime 2 b
Dividing the energy equation by N C p T 0 results in
T TES T 0 = Q N C p T 0 + θ r c + 1 N θ + 1 − 1 r t + 1 N r t .
This determines T TES and, therefore, Co P rt :
CoP rt = T TES − T 4 T 1 − T 0 = Q r c N C p T 0 + θ + 1 N r c θ + 1 − 1 r t + 1 N r t 1 − 1 r t 1 − 1 r c .
The useful work W = W t − W c increases with increasing W t as Q increases, while W c remains constant. Therefore,
W = W t − W c = W c CoP rt ( Q ) − 1
Differentiating this equation yields
δ W δ Q = W c δ CoP rt δ Q = r c − 1 θ + 1 − ( 1 − 1 / N ) / r t 1 r c ( 1 − 1 / r t ) ( 1 − 1 / r c )
where the equalities W c = N C p T 1 − T 0 and T 1 / T 0 = r c are taken into account. After simplification, we obtain
δ W δ Q = r t − 1 ( θ + 1 ) r t − 1 + 1 / N

3.3. Parameters for Transitional Regimes

Finally, we note that if no heat is added, Q = 0 , then
CoP rt = r t 2 r t − 1 f , f = ( 1 − 1 / r t ) ( 1 − 1 / r c )
The transition between regimes 1 and 2 requires the solar boost intensity of
Q N C p T 0 = 2 r t − 1 − r c = Θ 1
and corresponds to
CoP rt = r t r c f
Note that regime 1 can disappear when Θ 1 ≤ 0 and isentropic efficiencies are impractically small, for example, when η c ≤ 1 / 2 and η t = 1 . Regime 1 is suppressed when 2 r t − r c ≤ 1 — this implies small η c , small η t and/or large r p in conjunction with non-ideal efficiencies. If η c = η t = 1 , then r t = r c = r and Θ 1 = r − 1 > 0 .
The transition between regimes 2a and 2b requires
Q N C p T 0 = r c 1 − 1 r t + 1 N r c r t − 1 = Θ 2
Note that, in the isentropic case of η c = η t = 1 , regime 2a disappears due to Θ 2 = r − 1 = Θ 1 . The engine-type values of Co P rt ≥ 1 are achieved in regime 2b when the supplied heat Q exceeds
Q N C p T 0 = r c − 1 + 1 N r c − r t r t − 1 = Θ 3
Note that Θ 3 = Θ 2 in the isentropic case η c = η t = 1 .

4. Performance Metrics

4.1. The Round-Trip Coefficient of Performance

The round-trip Co P rt , which is defined as the ratio of work output ( W t ) to work input ( W c ) in equation (9), is a principal parameter characterising the performance of energy storage systems. In such systems, it represents the fraction of input electrical energy that can be recovered after a complete charge–discharge cycle. With the integration of a solar booster, either the required electrical input ( W c ) decreases in regime 1 or the work output ( W t ) increases in regime 2. The round-trip Co P rt tends to increase substantially with increasing solar boost and is a monotonically increasing function of Q in all regimes. In regimes 1 and 2a, Co P rt remains below 100% until regime 2b is achieved. The major role of the solar boost is to compensate for inevitable losses in the CAES system and to improve the operational round-trip efficiency. The practical attractiveness of this measure is associated with the relatively small modifications required to provide a solar boost and with the abundant availability of solar energy. Our findings about Co P rt are now summarised in form of a proposition.
Proposition 1. 
The round-trip coefficient of performance Co P rt of solar-boosted CAES with with single-temperature TES increases monotonically with increasing solar heat input and exceeds 100% when the external heat supplied to the system exceeds Q = N C p T 0 Θ 3 . With solar boosting, the CAES system is progressively transformed from a pure energy storage device into a hybrid solar-thermal generator.

4.2. Thermal Coefficient of Performance

The thermal performance of the system is assessed by the marginal thermal Co P th —a measure of how effectively the solar heat is utilised. This quantity is defined as the marginal increment of W = W t − W c divided by the increment of Q. The marginal approach produces clear results that depend on the operating regime. The overall ratio (i.e. W / Q instead of δ W / δ Q ) is more ambiguous, since W can be both positive and negative in different regimes, while W ( Q ) is a consistently monotonic function. Note that the increase δ W involves a combination of several factors, such as improved thermal performance and the reduction of losses associated with the storage system, while only overall (not marginal) characteristics are conventionally constrained by thermodynamic inequalities.
The expressions for Co P th in (24) and (32) are summarised in the tables for a general case
Table 2. Thermal Co P th expressions for non-isentropc case
Table 2. Thermal Co P th expressions for non-isentropc case
Regime CoP th Q range
1 1 − 1 r c = 1 − T 0 T 1 0 ≤ Q N C p T 0 ≤ Θ 1
2a r t − 1 2 r t − 1 + 1 / N Θ 1 ≤ Q N C p T 0 ≤ Θ 2
2b r t − 1 r t − 1 + 1 / N Θ 2 ≤ Q N C p T 0
and for isentropic compressor η c = 1 and isentropic turbine η t = 1 with r c = r t = r
Table 3. Thermal Co P th for isentropic compressor and turbine
Table 3. Thermal Co P th for isentropic compressor and turbine
Regime CoP th Q range
1 1 − 1 r = 1 − T 0 T TES 0 ≤ Q N C p T 0 ≤ r − 1
2b r − 1 r − 1 + 1 / N r − 1 ≤ Q N C p T 0
Note that, for regime 1, Co P th strongly resembles the efficiency of an ideal Brayton cycle,
η Brayton = 1 − 1 r Brayton , r Brayton = T 2 T 1 = T 3 T 4
using the conventional notation for the node temperatures T 1 , … , T 4 , although equation (24) reflects non-ideal (non-isentropic) effects in the performance of the turbine and compressor. Note that this equation can apparently outperform the efficiency of a Carnot cycle η Carnot = 1 − T 0 / T TES operating between temperatures T TES and T 0 since T 1 ≥ T TES in regime 1. This is because Co P th characterises marginal properties of a complex system such as CAES and not overall efficiency performance of a heat engine. These comparisons nevertheless show the benefits of solar boosting, which can utilise additional solar heat efficiently by reducing losses associated with CAES. Our analysis of Co P th indicates that:
Proposition 2. 
The marginal thermal coefficient of performance Co P th of solar-boosted CAES with single-temperature TES characterises the incremental efficiency of converting additional solar heat into additional useful work. As a marginal quantity, it is not constrained by the upper bound set by the Carnot efficiency and may approach unity under some conditions (regime 2b, N → ∞ ).

4.3. Second-Law Efficiency

While the previous sections demonstrate relatively high values of CoP associated with two different aspects of practical performance of the system, namely energy return and heat-to-work conversion, a proper thermodynamic efficiency of the solar-boosted CAES system also needs to be analysed. Since two different energy inputs are used, namely work W c and heat Q, the second-law efficiency must be employed to characterise properly the quality of these inputs. Specifically, the second-law efficiency is defined as
η II = E r E s = W T W C + Q x , x = 1 − T 0 T TES
where E s is spent exergy, E r is recovered exergy, and x characterises the quality of the heat. In this section we prove the following theorem, which establishes a fundamental constraint that is clearly consistent ( η II < 1 ) with the second law of thermodynamics:
Theorem 1. 
The second law efficiency of an advanced CAES system with solar-boosted single-temperature TES is subject to the following upper bound
η II ≤ 1 + r t − 1 T 0 T TES − 1 < 1
which can be written for regime 1 as
η II ≤ T TES T TES + ( T TES − T 0 ) < 1
Proof of Theorem 1. 
The proof below demonstrates that
1 η II ≥ 1 + r t − 1 y , y = T TES T 0
equivalently to (40). It is clear that η II < 1 in this equation since r t > 1 and y > 0 .
Let U be the total heat transferred from compression to TES during one complete cycle, and let
R = C p ( T 4 − T 0 ) ≥ 0
represent the extra heating from T 0 to T 4 before the first expansion stage. Since the TES supplies the turbine heating, its balance is
Q + U = W T + R .
Hence
1 η II = W C + Q x W T = W C + x ( W T − U + R ) W T ≥ x + W C − x U W T .
Now consider one compression stage with inlet temperature T in , outlet temperature T out = r c T in , work
w c = C p ( T out − T in ) ,
and heat transferred to TES
u = C p ( T out − T TES ) , T out > T TES 0 T out ≤ T TES
Here either T in = T 0 and T out = T 1 for the first compressor stage or T in = T 2 and T out = T 3 for the subsequent stages. We claim that for every stage
w c − x u ≥ C p T 0 ( r t − 1 ) .
If u = 0 , then
w c − x u = w c = C p T in ( r c − 1 ) ≥ C p T 0 ( r t − 1 ) ,
since T in ≥ T 0 and r c ≥ r t .
If u > 0 , then T out > T TES , and
w c − x u = C p ( T out − T in ) − 1 − T 0 T TES ( T out − T TES ) = C p T TES − T in + T 0 T TES ( T out − T TES ) .
Let α = T in / T 0 . Then T out = r c α T 0 , and
w c − x u C p T 0 − ( r t − 1 ) = y − α + r c α − y y − ( r t − 1 ) = ( y − r t ) 1 − α y + α ( r c − r t ) y .
For any stage transferring heat to TES one has T in ≤ T TES , that is, α ≤ y . Since also r c ≥ r t and T 4 ≥ T 0 that is y ≥ r t , the right-hand side is non-negative, proving (45).
Summing (45) over all N compression stages gives
W C − x U ≥ N C p T 0 ( r t − 1 ) .
On the other hand,
W T = N C p ( T TES − T 4 ) = N C p T 0 y 1 − 1 r t ,
and therefore
N C p T 0 ( r t − 1 ) = W T r t y .
Using this in (44) yields
1 η II ≥ 1 − 1 y + r t y = 1 + r t − 1 y = 1 + r t − 1 T 0 T TES ,
which proves (42).
In regime 1, T 4 = T 0 and thus r t = T TES / T 0 = y , so (42) reduces to
1 η II ≥ 2 − T 0 T TES .
which is equivalent to (41). The substance of the theorem is proven. □

5. Conclusions

This work presents a mathematical analysis of an ideal adiabatic CAES system with single-temperature thermal energy storage (TES) integrated with an external heat booster supplied by concentrated solar energy or, possibly, other energy sources, such as combustion or some suitable residual heat. Two principal operating regimes are identified: (1) solar-assisted CAES and (2) energy storage with solar co-generation. A closed-form relationship between the round-trip CoP, pressure ratio, and heat-boost parameter is derived, providing a transparent basis for evaluating work extraction from the system. The analysis shows that the maximum work obtainable from an incremental solar heat input can be high, even in comparison with the Carnot efficiency. In addition, the integrated system can achieve a high electrical round-trip coefficient of performance, which, in regime 2, can exceed 100% when the solar boost is sufficiently large. These findings demonstrate the practical advantages of solar boosting in CAES systems. The work also establishes an upper bound for the overall second-law efficiency of the system and shows that the latter remains fully consistent with the laws of thermodynamics.

Author Contributions

Conceptualisation and methodology, A.Y.Klimenko and A.Samant; coding, validation and writing, A.Samant and A.Y.Klimenko; analysis, editing and overview, A.Samant, Y.Lu and M.Kumar; funding acquisition and project administration, A.Y.Klimenko. All authors have read and agreed to the published version of the manuscript.

Funding

This research has received external funding from QCAS funding scheme

Conflicts of Interest

The authors declare no conflicts of interest.

Abbreviations

The following abbreviations are used in this manuscript:
A-CAES Adiabatic Compressed Air Energy Storage
CAES Compressed Air Energy Storage
TES Thermal Energy Storage
CoP Coefficient of Performance
Co P rt Round-trip Coefficient of Performance
Co P th Marginal Thermal Coefficient of Performance
η II Second-law efficiency
T–S diagram Temperature–Entropy diagram

References

  1. Green, D.S.; Kratzer, M.M.; Chapman, A.; Lu, Y.; Klimenko, A.Y. Emergence of intermittency in electricity prices and its modelling in the context of energy transition: a comparison to turbulent cascades. Sustainable Energy, Grids and Networks 2025, 44, 101992. [Google Scholar] [CrossRef]
  2. Jankowski, M.; et al. Status and development perspectives of the compressed air energy storage (CAES) technologies—A literature review. Energies 2024, 17(9), 2064. [Google Scholar] [CrossRef]
  3. Chinese Academy of Sciences. (2022) World’s first 100-MW advanced compressed air energy storage plant connected to grid for power generation.
  4. China Academy of Sciences. (2024) World’s largest 300MW/1800MWh advanced compressed air energy storage station first grid-connected, 30 April.
  5. Samant, A.; Klimenko, A. Y. (2026) Thermodynamic analysis of a multistage compressed air energy storage with a single temperature thermal energy storage. Australian Combustion Symposium 2025, Brisbane, 1-4 December 2025. Brisbane: UQ.
  6. Elalfy, D.A.; et al. Comprehensive review of energy storage systems technologies, objectives, challenges, and future trends. Energy strategy reviews Available at. 2024, 54(101482), 101482. [Google Scholar] [CrossRef]
  7. Staadecker, M.; et al. The value of long-duration energy storage under various grid conditions in a zero-emissions future. Nature communications 2024, 15(1), 9501. [Google Scholar] [CrossRef] [PubMed]
  8. Moa, E.H.Y.; Go, Y. Large-scale energy storage system: safety and risk assessment. Sustainable energy research 2023, 10(1). [Google Scholar] [CrossRef]
  9. Zhang, X.; et al. Advanced compressed air energy storage systems: Fundamentals and applications. Engineering (Beijing, China) 2024, 34, 246–269. [Google Scholar] [CrossRef]
  10. Rabi, A.; Radulovic, J.; Buick, J. Comprehensive review of compressed Air Energy Storage (CAES) technologies. Thermo 2023, 3(1), 104–126. [Google Scholar] [CrossRef]
  11. Qin, H.; Chen, W.; Zhang, T.; Ma, L.; Xue, X.; Zhang, X. Thermal analysis and parameter optimization of advanced adiabatic compressed air energy storage with parabolic trough solar collector auxiliary reheating. Journal of Energy Storage 2025, 110(115104), 115104. [Google Scholar] [CrossRef]
Figure 1. Integrated adiabatic CAES system with solar booster.
Figure 1. Integrated adiabatic CAES system with solar booster.
Preprints 209910 g001
Figure 2. T–S plot of the integrated cycle in regime 1 with non-isentropic compressors and turbines. Dashed lines and "prime" superscripts indicate corresponding isentropic values. Blue lines indicate compression stages and red lines indicate turbine stages.
Figure 2. T–S plot of the integrated cycle in regime 1 with non-isentropic compressors and turbines. Dashed lines and "prime" superscripts indicate corresponding isentropic values. Blue lines indicate compression stages and red lines indicate turbine stages.
Preprints 209910 g002
Figure 3. T–S plot of the integrated cycle at regime 1 to regime 2 transition. Notations are as in the previous figures.
Figure 3. T–S plot of the integrated cycle at regime 1 to regime 2 transition. Notations are as in the previous figures.
Preprints 209910 g003
Figure 4. T–S plot of the integrated cycle in regime 2a. Notations are as in the previous figures.
Figure 4. T–S plot of the integrated cycle in regime 2a. Notations are as in the previous figures.
Preprints 209910 g004
Figure 5. T–S plot of the integrated cycle in regime 2b. Notations are as in the previous figures.
Figure 5. T–S plot of the integrated cycle in regime 2b. Notations are as in the previous figures.
Preprints 209910 g005
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.
Copyright: This open access article is published under a Creative Commons CC BY 4.0 license, which permit the free download, distribution, and reuse, provided that the author and preprint are cited in any reuse.