6.1. Historical Ccrit Values
A common discrete value quoted in the literature for C
crit is 0.4 WPC. Generally, it is not noted what statistic this represents but it is consistent with distributions given in fib 34 [
1] when considered as a characteristic value with 5-10% chance of structures corroding at this value, i.e. it is a safe design value. It has been reported that reinforcement in some structures show no signs of corrosion long after the 0.4 WPC C
crit is reached. This may be largely because 95% of structures should show no corrosion at this chloride level. However, there are other reasons why the critical chloride level could be higher than that the current values in fib 34.
Gulikers [
10] reviewed the critical chlorides giving in fib Bulletin’s 34 [
1] and 76 [
11] and those given in Duracrete [
12]. The fib values were as proposed by Gehlen [
13]. Originally values for the mean (0.5% WPC) and standard deviation (0.15%), came from the experimental work by Breit [
14] on ‘lollipop’ samples. However, Gehlen, considered 0.5% too conservative/unrealistic for practice. Therefore, he increased the mean from 0.5% to 0.6% but maintained the same value for the standard deviation. The limits on the beta distribution are 0.2 and 2 WPC. Gehlen gave no further support or experimental evidence for the increase by 0.1% although various papers by authors he associated with suggest much higher values occur. The only limitation given for C
crit is that it applies to mild steel only.
Gulikers [
10] also notes Duracrete [
12] had C
crit distributions for different exposures and w/c as shown in
Table 1. These were values based on visible concrete damage. This raises the question as to why different values were not published in fib for different concrete qualities and exposures. Given the low C
crit for concrete with a w/c of 0.5, and that in practice concrete with a w/c ratio of 0.5 should not be used in marine concrete, it might be reasonable to propose C
crit for splash zone for high performance and moderate performance concrete, coinciding with w/c ratios of 0.3-0.35 and 0.35-0.4, at a much higher mean value than currently given in fib Bulletin 34 [
1].
Notably no values are given for coastal concrete.
Even before publication of fib Bulletin 34 [
1] there had been extensive research on values for C
crit. Since fib 34 there has been much more research. Yet, or maybe because, there has been no unifying research.
Among other older values, it is important to emphasize that Melchers [
15] gives examples where chloride concentrations at the bar were much higher than fib C
crit with no corrosion. This is consistent with other research where the chlorides needed for corrosion were much higher than those used by fib 34 [
1]. This gave concern that using the Model with C
crit might lead to overly conservative designs, and that chloride ingress may not be the most appropriate modelling approach.
The European perspective was very much on the need for far better guidance on the use of Ccrit now that modelling is finding wide usage amongst engineers with little research background. It was necessary to ensure designs were safe, but not overly conservative. However, there was still concern that factors other than chlorides at the bar were not adequately accounted for in determining if corrosion would occur.
One of the lead C
crit researchers, Ueli Angst, in one paper [
16] made within the work of RILEM TC 235, a review of factors at the steel concrete interface that affect C
crit is given. Ueli et al. summarized these as:
The degree to which steel is polished, the steel metallurgy, and the moisture content at the Steel: Concrete Interface (SCI) are by far the most dominant influencing characteristics.
Cement type and w/b ratio have comparatively small effects.
Corrosion at macroscopic interfacial voids depends on the moisture states, with partially filled voids representing the worst case.
The relative degree of corrosion sometime after initiation can be affected by propagation as well as initiation. Reported advanced corrosion at bleed lenses, for example, are more a function of high propagation rates than low Ccrit.
In another [
17], also with coworkers, it is proposed that rather than continuing to focus on corrosion as T0 + T1, with C
crit related to T0, the corrosion process be considered as one continuum including initiation and propagation, but without proposing how to apply this concept, while the Condition Limit State previously adopted in Eurocode 2 is a practical approach.
The Bulletin draws the conclusion that it is not possible at this stage to provide a relationship between all the factors affecting C
crit. The best that can be expected is to place limits of application on C
crit distributions proposed. The lack of limits is seen as a flaw in the fib Bulletin 34 [
1] C
crit distribution. The Bulletin will give insight into the issues of developing C
crit for different situations. Also the Bulletin, following MC2020, supports the incorporation of a certain propagation period to the nominal service life, that is the adoption of a new limit state of corrosion (CLS) that in certain exposure classes adds a propagation period because the expected corrosion rate is low and the pit depth is limited for a sustained period of time.
6.2. Recent Research on Ccrit
This adoption of the CLS was deeply discussed by an ad-hoc group when preparing MC2020, deciding to apply it not only to chloride induced corrosion, but also to carbonation and the other types of attack or damage. The concept has been defined as “Condition Limit State” and can be applied to other deterioration mechanisms. In the particular case of chloride attack, Andrade [
Figure 1] showed that fib [
1] criteria on C
crit were supported by other authors and hence fib 34 could be used even though other distributions are found in the literature (
Figure 1). In some cases, the reasons for the higher standard deviation values are unclear because they come from site measurements (Angst) where perhaps the concrete moisture content is variable, while in others it is known (Izquierdo <-200 mv) because they are the result of laboratory well controlled testing.
Conversely Angst [
19] highlights three studies shown in red, three in yellow and two in blue (
Figure 2) showing different clusters for higher C
crit distributions. This suggest three studies cannot be randomly picked as agreeing and are therefore C
crit should be supposed with a lower standard deviation. That is, even though higher C
crit distributions may be used by engineers, the criteria published for general use must be a lower bound, i.e. fib [
1] values.
6.3. Different Ccrit for Different Circumstances
TG 8.9.3 had considerable discussion on the fib [
1] C
crit distribution as discussed in
Section 6. Papworth [
8] considered how the wide distribution in fib [
1] could be reasonably applied for all concrete. His
Figure 4a shows five distributions based on a single contrived data set for C
crit. The whole data set fits the distribution given in fib [
1]. The other four distributions take a portion of the whole date set splitting the data into four sets potentially representing different qualities. The meaning of quality is deliberately not defined and could be aspects of the interface and/or the mix. This was so that an assessment of the influence of quality on C
crit could be made by using the various distributions to assess the reliability of a structure where all the other inputs were held constant in a full probabilistic analysis (
Figure 4b). It must be born in mind that these distributions are only for values making up the fib [
1] C
crit distribution. Higher distribution would give even higher reliability than shown here.
Figure 4b shows the fib 34 distribution gives a reliability of 1.4 at 100 years and this might be taken as just less than ideal where a target reliability of 1.5 would be required for before a first crack limit state, i.e. for example a minor increase in cover might be required. If the distribution represents concrete at the poor and high end of the quality spectrums the reliability was around 1.1 and 1.7 respectively. That represents a significant difference in cover required. As noted earlier there was already concern that the fib [
1] C
crit distribution underestimated the resistance to chloride in some situations and strengthened the idea that different distributions should be used for different qualities, if those qualities could be defined.
6.4. Application Limits for Ccrit
Possible C
crit values were tabled, together with potential limitations of use, (
Table 2) for TG 8.9.3 consideration.
Diffusion coefficient was included as a general measure of quality as it is a test likely to be required for chloride environments as a measure of chloride ingress rate. The requirement for testing on representative trial blocks and first pours was an attempt to ensure assessment was based on site concrete rather than laboratory samples. Voids and porosity were intended to give some measure of voidage at the SCI while steel composition and surface condition were an attempt to bring in other SCI properties.
Strong responses to the possible limits in
Table 2 were:
- a)
It is the SCI that is responsible for C
crit and the measures in
Table 2 mainly considered the concrete’s general quality, and they would not deal adequately with qualifying the interface.
- b)
In terms of general concrete quality, the normal requirements for concrete for each exposure were adequate. No additional restrictions are required.
- c)
Any measure for Ccrit needed to be based on the real as placed concrete and not laboratory samples.
On the other hand, an attempt to classify the concrete quality with respect to reinforcement corrosion is being made in CEN TC 104-Concrete related to the new EN-206 and it is based in classifying the concretes in function of their carbonation rate or chloride diffusion coefficient obtained in tests at short time, already standardized. The values of the rates of ingress are classified from lower to higher in “Exposure Resistance Classes (ERC)” that serve to specify the associated cover depths, that were calculated through different levels of service life models.
It is clear that the influencing factors has to be drawn from the SCI and proxy measures of concrete mix or insitu performance of the bulk concrete would not provide realistic limitations. A detailed report [
20] on methods of characterizing the SCI outlines
“current methods (laboratory or field-based) for characterizing local properties of the SCI that have been identified as governing factors affecting corrosion initiation. These properties include characteristics of the steel such as mill scale and rust layers, and characteristics of the concrete such as interfacial voids, microstructure and moisture content.” It notes various limitation for a full characterization of the SCI but more positively notes
“established techniques are available for direct quantitative characterization of selected features, namely mill scale and rust layers on the steel surface, and the interfacial voids and microstructure of the cementitious matrix at the SCI.”
While SCI characterization is as yet imperfect some of the key aspects for which tests are available might at least be require additional tests when establishing Ccrit. These might include pH, Interface Voids, Potentials, Temperature, Relative Humidity.
6.6. Under Water Corrosion
The corrosion of steel in immersed concrete is not well understood. It is often stated that oxygen starvation of the cathodic areas in underwater concrete means corrosion is not an issue. Papworth [
22] notes that this might not be the cause of the lack of corrosion. It might be that in pores saturated with highly alkaline seawater the high pH leads to a high critical chloride level consistent with Pourbaix. Various authors [
23,
24,
25] report mean critical chloride levels of around 2% by weight cement in immersed zones compared to 0.6% by weight cement given in fib [
1] for atmospheric zones. Also, this is deduced from the work in [
19].
The chloride profiles of immersed seawater exposed structures differ to those of above water structure significantly. Browne [
26] showed a flatter chloride profile for immersed concrete than splash zone concrete (
Figure 3a). Even though the surface chloride in the underwater zone was less than half that in the splash zone the chloride level at 150mm deep was higher after 34 years. The chloride levels found by Walsh [
27] after 60 years (
Figure 3b) were virtually flat having reached a maximum at 9-12kg/m
3.
The chloride profiles and critical chloride level are significant as they show the care required when applying the MC Model.
Walsh [
27] reports that he examined sections from submerged piles in the laboratory and there was extensive localised corrosion on the face of many bars that faced the exposed surface (Figure 7a). The corrosion products had not caused spalling but had migrated away from the bar (Figure 7b). The resulting perimeter-averaged values for the corroding regions typically ranged from 5 μm/y to 35 μm/y and were randomly distributed and considered to occur at local concrete deficiencies. In Walsh’s piles corrosion was limited to 6% and 12% of the bar lengths in two piles. Walsh notes that Beaton’s results were similar.
The importance of this is that it shows that where concrete is locally deficient, such as at honeycombing, corrosion can occur, but the corrosion rate will be low. However, at honeycombed concrete corrosion initiation would be expected to occur in the early life and hence the corrosion rate would apply over virtually the whole design life. The corrosion rate can be taken to be 5-35 μm/y. Over a 160-year design life this would translate to 0.8-5.6mm averaged around the bar (i.e. thicker loss expected but only on one side) and apply in limited areas of honey combing. The corrosion will not result in spalling but in migration of iron ions away from the reinforcement.
Walsh[ [
27] states “
Consequently, if corrosion at a spot in the submerged region started relatively early in the life of the structure, e.g., as a result of a local concrete deficiency, that spot may tend to remain a relatively stable feature over a long period of time. Such a situation would be consistent with the field observations noted … where relatively small localized corroding regions were found to be surrounded by large amounts of non-corroding steel, much of which exhibited an undisturbed surface appearance.”
Although slow the corrosion in immersed zones may lead to significant localised corrosion over a 100 year design life. Because the corrosion rate will be slow, and the corrosion products are not expansive, this is not likely to be a structural issue for many decades. The Bulletin proposes that the Model is not the appropriate tool for immersed concrete analysis but rather an allowance for localised corrosion should be applied.