Submitted:
29 May 2024
Posted:
30 May 2024
You are already at the latest version
Abstract
Keywords:
I. Introduction
II. Experimental Setup
A. ALLS 150 TW Ti:Sapphire Laser
B. TNSA-Based Proton Acceleration
C. Neutron Emissions
1. Diagnostics
2. Monte-Carlo Simulations
III. Assessment of Neutron Emissions
A. Activation Measurements
1. Direct Measurement of the LiF Converter
2. Indium Sample
B. Bubble Detectors
IV. Discussion
Data Availability Statement
Acknowledgments
Conflicts of Interest
References
- Disdier, L.; Garçonnet, J.P.; Malka, G.; Miquel, J.L. Fast Neutron Emission from a High-Energy Ion Beam Produced by a High-Intensity Subpicosecond Laser Pulse. Phys. Rev. Lett. 1999, 82, 1454. [Google Scholar] [CrossRef]
- Lancaster, K.L. Characterization of Li7(p,n)7Be neutron yields from laser produced ion beams for fast neutron radiography. Phys. Plasmas 2004, 11, 3404–3408. [Google Scholar] [CrossRef]
- Alejo, A.; Ahmed, H.; Green, J.; Mirfayzi, S.; Borghesi, M.; Kar, S. Recent advances in laser-driven neutron sources. Nuovo Cimento C 2016, 38C, 1–7. [Google Scholar]
- Alvarez, J.; Fernández-Tobias, J.; Mima, K.; Nakai, S.; Kar, S.; Kato, Y.; Perlado, J. Laser Driven Neutron Sources: Characteristics, Applications and Prospects. Physics Procedia 2014, 60, 29–38. [Google Scholar] [CrossRef]
- Pomerantz, I. Ultrashort Pulsed Neutron Source. Physical Review Letters 2014, 113. [Google Scholar] [CrossRef] [PubMed]
- Higginson, D.P. Temporal Narrowing of Neutrons Produced by High-Intensity Short-Pulse Lasers. Physical Review Letters 2015, 115. [Google Scholar] [CrossRef]
- Roth, M. Bright Laser-Driven Neutron Source Based on the Relativistic Transparency of Solids. Phys. Rev. Lett. 2013, 110, 044802. [Google Scholar] [CrossRef] [PubMed]
- Kleinschmidt, A.; Bagnoud, V.; Deppert, O.; Favalli, A.; Frydrych, S.; Hornung, J.; Jahn, D.; Schaumann, G.; Tebartz, A.; Wagner, F.; Wurden, G.; Zielbauer, B.; Roth, M. Intense, directed neutron beams from a laser-driven neutron source at PHELIX. Phys. Plasmas 2018, 25, 053101. [Google Scholar] [CrossRef]
- Hornỳ, V.; Chen, S.N.; Davoine, X.; Lelasseux, V.; Gremillet, L.; Fuchs, J. High-flux neutron generation by laser-accelerated ions from single-and double-layer targets. Sci. Rep. 2022, 12, 19767. [Google Scholar] [CrossRef]
- Martinez, B. Numerical investigation of spallation neutrons generated from petawatt-scale laser-driven proton beams. Matter Radiat. Extremes 2021, 7, 024401. [Google Scholar] [CrossRef]
- https://www.starfireindustries.com/ngen.html.
- Comsan, M. Spallation Neutron Sources For Science And Technology. Proceedings of the eighth Nuclear and Particle Physics Conference (NUPPAC-2011), (p. 287). Egypt 2011.
- Chen, S.N.; Negoita, F.; Spohr, K.; d’Humières, E.; Pomerantz, I.; Fuchs, J. Extreme brightness laser-based neutron pulses as a pathway for investigating nucleosynthesis in the laboratory. Matter Radiat. Extremes 2019, 4. [Google Scholar] [CrossRef]
- Horný, V.; Chen, S.N.; Davoine, X.; Gremillet, L.; Fuchs, J. Quantitative feasibility study of sequential neutron captures using intense lasers. Physical Review C 2024, 109. [Google Scholar] [CrossRef]
- Brenner, C.M. Laser-driven x-ray and neutron source development for industrial applications of plasma accelerators. Plasma Physics and Controlled Fusion 2015, 58, 014039. [Google Scholar] [CrossRef]
- Martz, H.E., Jr.; Glenn, S. Nuclear techniques to detect explosives. In Counterterrorist Detection Techniques of Explosives; Elsevier, 2022; pp. 339–381.
- Buffler, A. Contraband detection with fast neutrons. Radiat. Phys. Chem. 2004, 71, 853–861. [Google Scholar] [CrossRef]
- Buffler, A.; Tickner, J. Detecting contraband using neutrons: challenges and future directions. Radiation Measurements 2010, 45, 1186–1192. [Google Scholar] [CrossRef]
- Yogo, A. Laser-driven neutron generation realizing single-shot resonance spectroscopy. Phys. Rev. X 2023, 13, 011011. [Google Scholar] [CrossRef]
- Kishon, I.; Kleinschmidt, A.; Schanz, V.; Tebartz, A.; Noam, O.; Fernandez, J.; Gautier, D.; Johnson, R.; Shimada, T.; Wurden, G.; Roth, M.; Pomerantz, I. Laser based neutron spectroscopy. Nuc. Instrum. Meth. A 2019, 932, 27–30. [Google Scholar] [CrossRef]
- Révay, Z.; Lindstrom, R.M.; Mackey, E.A.; Belgya, T. Handbook of Nuclear Chemistry: Vol. 3: Chemical Applications of Nuclear Reactions and Radiation, second ed.; Vol. 3, Handbook of Nuclear Chemistry, Springer US, 2010.
- Smit, Z.; Maróti, B.; Kasztovszky, Z.; Semrov, A.; Kos, R. Analysis of Celtic small silver coins from Slovenia by PIXE and PGAAR. Archaeological and Anthropological Sciences 2020, 12, 155. [Google Scholar] [CrossRef]
- Belgya, T. Prompt Gamma Activation Analysis at the Budapest Research Reactor. Physics Procedia 2012, 31, 99–109. [Google Scholar] [CrossRef]
- Knight, B.M.; Gautam, C.M.; Stoner, C.R.; Egner, B.V.; Smith, J.R.; Orban, C.M.; Manfredi, J.J.; Frische, K.D.; Dexter, M.L.; Chowdhury, E.A.; Patnaik, A.K. Detailed characterization of kHz-rate laser-driven fusion at a thin liquid sheet with a neutron detection suite. High Power Laser Science and Engineering 2023, 12. [Google Scholar] [CrossRef]
- Catrix, E.; Boivin, F.; Langlois, K.; Vallières, S.; Boynukara, C.Y.; Fourmaux, S.; Antici, P. Stable high repetition-rate laser-driven proton beam production for multidisciplinary applications on the Advanced Laser Light Source ion beamline. Review of Scientific Instruments 2023, 94, 103003. [Google Scholar] [CrossRef] [PubMed]
- Wilks, S.C.; Langdon, A.B.; Cowan, T.E.; Roth, M.; Singh, M.; Hatchett, S.; Key, M.H.; Pennington, D.; MacKinnon, A.; Snavely, R.A. Energetic proton generation in ultra-intense laser–solid interactions. Phys. Plasmas 2001, 8, 542–549. [Google Scholar] [CrossRef]
- Snavely, R.A. Intense High-Energy Proton Beams from Petawatt-Laser Irradiation of Solids. Phys. Rev. Lett. 2000, 85, 2945–2948. [Google Scholar] [CrossRef] [PubMed]
- Romagnani, L.; Fuchs, J.; Borghesi, M.; Antici, P.; Audebert, P.; Ceccherini, F.; Cowan, T.; Grismayer, T.; Kar, S.; Macchi, A.; Mora, P.; Pretzler, G.; Schiavi, A.; Toncian, T.; Willi, O. Dynamics of Electric Fields Driving the Laser Acceleration of Multi-MeV Protons. Phys. Rev. Lett. 2005, 95, 195001. [Google Scholar] [CrossRef] [PubMed]
- Agostinelli, S. Geant4—a simulation toolkit. Nuc. Instrum. Meth. A 2003, 506, 250–303. [Google Scholar] [CrossRef]
- Thompson, W.L. MCNP, a general Monte Carlo code for neutron and photon transport: a summary 1979.
- Vallières, S.; Salvadori, M.; Puyuelo-Valdes, P.; Payeur, S.; Fourmaux, S.; Consoli, F.; Verona, C.; d’Humières, E.; Chicoine, M.; Roorda, S.; Schiettekatte, F.; Antici, P. Thomson parabola and time-of-flight detector cross-calibration methodology on the ALLS 100 TW laser-driven ion acceleration beamline. Review of Scientific Instruments 2020, 91, 103303. [Google Scholar] [CrossRef] [PubMed]
- Brown, D.A.; Chadwick, M.; Capote, R.; Kahler, A.; Trkov, A.; Herman, M.; Sonzogni, A.; Danon, Y.; Carlson, A.; Dunn, M. ENDF/B-VIII.0: the 8th major release of the nuclear reaction data library with CIELO-project cross sections, new standards and thermal scattering data. Nuclear Data Sheets 2018, 148, 1–142. [Google Scholar] [CrossRef]
- Koning, A.; Rochman, D.; Sublet, J.C.; Dzysiuk, N.; Fleming, M.; Van der Marck, S. TENDL: complete nuclear data library for innovative nuclear science and technology. Nuclear Data Sheets 2019, 155, 1–55. [Google Scholar] [CrossRef]
- Higginson, D.P. Global Characterization of a Laser-Generated Neutron Source, 2023.
- Lelièvre, R. A Comprehensive Characterization of the Neutron Fields Produced by the APOLLON Petawatt Laser. arXiv, 2023; arXiv:2311.12653. [Google Scholar]
- Ing, H.; Noulty, R.; McLean, T. Bubble detectors—a maturing technology. Radiation measurements 1997, 27, 1–11. [Google Scholar] [CrossRef]
- Trkov, A. IRDFF-II: A New Neutron Metrology Library. Nuclear Data Sheets 2020, 163, 1–108. [Google Scholar] [CrossRef]
- Mancic, A. Isochoric heating of solids by laser-accelerated protons: Experimental characterization and self-consistent hydrodynamic modeling. High Energy Density Physics 2010, 6, 21–28. [Google Scholar] [CrossRef]
- Vidmar, T. EFFTRAN—A Monte Carlo efficiency transfer code for gamma-ray spectrometry. Nuc. Instrume. Meth. A. 2005, 550, 603–608. [Google Scholar] [CrossRef]
- Chagren, S.; Tekaya, M.B.; Reguigui, N.; Gharbi, F. Efficiency transfer using the GEANT4 code of CERN for HPGe gamma spectrometry. Applied Radiation and Isotopes 2016, 107, 359–365. [Google Scholar] [CrossRef]
- Moens, L.; De Donder, J.; Xi-Lei, L.; De Corte, F.; De Wispelaere, A.; Simonits, A.; Hoste, J. Calculation of the absolute peak efficiency of gamma-ray detectors for different counting geometries. Nuc. Instrum. Meth. 1981, 187, 451–472. [Google Scholar] [CrossRef]
- Gressier, V.; Guerre-Chaley, J.F.; Lacoste, V.; Lebreton, L.; Pelcot, G.; Pochat, J.L.; Bolognese-Milstajn, T.; Champion, D. AMANDE: a new facility for monoenergetic neutron fields production between 2 keV and 20 MeV. Radiation Protection Dosimetry 2004, 110, 49–52. [Google Scholar] [CrossRef] [PubMed]
- Yogo, A. Single shot radiography by a bright source of laser-driven thermal neutrons and x-rays. Appl. Phys. Express 2021, 14, 106001. [Google Scholar] [CrossRef]
- Zimmer, M. Demonstration of non-destructive and isotope-sensitive material analysis using a short-pulsed laser-driven epi-thermal neutron source. Nature Communications 2022, 13, 1173. [Google Scholar] [CrossRef] [PubMed]
- Puyuelo-Valdes, P.; Vallières, S.; Salvadori, M.; Fourmaux, S.; Payeur, S.; Kieffer, J.C.; Hannachi, F.; Antici, P. Combined laser-based X-ray fluorescence and particle-induced X-ray emission for versatile multi-element analysis. Sci. Rep. 2021, 11, 9998. [Google Scholar] [CrossRef] [PubMed]
- Williams, D.L.; Brown, C.M.; Tong, D.; Sulyman, A.; Gary, C.K. A Fast Neutron Radiography System Using a High Yield Portable DT Neutron Source. Journal of Imaging 2020, 6. [Google Scholar] [CrossRef] [PubMed]
- Zboray, R.; Adams, R.; Kis, Z. Scintillator screen development for fast neutron radiography and tomography and its application at the beamline of the 10 MW BNC research reactor. Applied Radiation and Isotopes 2018, 140, 215–223. [Google Scholar] [CrossRef] [PubMed]
- Bergaoui, K.; Reguigui, N.; Gary, C.K.; Cremer, J.T.; Vainionpaa, J.H.; Piestrup, M.A. Design, testing and optimization of a neutron radiography system based on a Deuterium–Deuterium (D–D) neutron generator. J. Radioanal. Nucl. Chem. 2014, 299, 41–51. [Google Scholar] [CrossRef]


| /shot | /shot | ||
| Reaction | (Bq) | (Bq) | (%) |
| 0.082 | 0.072 | 13.0% | |
| 0.240 | 0.065 | 29.5% | |
| 0.022 | 0.013 | 31.3% |
| Quantity | Energy | |||
| range | (%) | |||
| Total | All | |||
| neutron yield | neutrons | 13.0% | ||
| (n/shot) | ||||
| Neutron | 0 | 0 | - | |
| fluences | [2-10 MeV] | 31.3% | ||
| (n/sr/shot) | [0.2-15 MeV] | 10.9% |
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).