A High-Performance Stability-Indicating Liquid Chromatographic Novel Method for Determining Recombinant Human Erythropoietin in Bulk and Dosage Form

Version 1 : Received: 29 November 2022 / Approved: 30 November 2022 / Online: 30 November 2022 (14:14:51 CET)

How to cite: Kothawade, S.N.; Pande, V.V.; Albhar, S.N.; Bole, S.S.; Raut, K.G.; Wagh, V.S. A High-Performance Stability-Indicating Liquid Chromatographic Novel Method for Determining Recombinant Human Erythropoietin in Bulk and Dosage Form. Preprints 2022, 2022110577. https://doi.org/10.20944/preprints202211.0577.v1 Kothawade, S.N.; Pande, V.V.; Albhar, S.N.; Bole, S.S.; Raut, K.G.; Wagh, V.S. A High-Performance Stability-Indicating Liquid Chromatographic Novel Method for Determining Recombinant Human Erythropoietin in Bulk and Dosage Form. Preprints 2022, 2022110577. https://doi.org/10.20944/preprints202211.0577.v1

Abstract

An HPLC method for indicating stability was developed, created, and confirmed for the quantification measurement of recombinant human erythropoietin in large quantities as well as dosage forms. An isocratic separation was accomplished using a Thermo Biobasic C18 (250 mm 4.6 mm i.d., 300Ao, 5 m) column with a flow rate of 1.0 mL min-1 as well as a UV detector to monitor the eluate at 278 nm. Acetonitrile, 0.05 mM potassium dihydrogen phosphate (80:20 v/v), and orthophosphoric acid adjusted to 4.0 made up the mobile phase. The drug was exposed to oxidative stress, hydrolysis, and photodegradation to simulate stress conditionsRecombinant Human Erythropoietin, the parent compound, was eluted at roughly 6.675 minutes, as well as all byproducts have been entirely disconnected inside an overall analytical run time of about 15 minutes. To identify quantification limits of 0.05 and 0.2 g mL-1, respectively, the method was linear over a concentration range of 1-6 g mL-1 (r = 0.9989). Recombinant Human Erythropoietin can be measured accurately, selectively, sensitively, and precisely using this method both in dosage form and in bulk. Stress-induced degradation products did not interact with the identification of Recombinant Human Erythropoietin, indicating that the assay is stable.

Keywords

Recombinant Human Erythropoietin; Stability-indicating; Reverse phase; HPLC-UV

Subject

Chemistry and Materials Science, Materials Science and Technology

Comments (0)

We encourage comments and feedback from a broad range of readers. See criteria for comments and our Diversity statement.

Leave a public comment
Send a private comment to the author(s)
* All users must log in before leaving a comment
Views 0
Downloads 0
Comments 0
Metrics 0


×
Alerts
Notify me about updates to this article or when a peer-reviewed version is published.
We use cookies on our website to ensure you get the best experience.
Read more about our cookies here.