Effectiveness of 6-Ischemic Cuff Near Infrared Spectroscopy Mitochondrial Capactity Test

Version 1 : Received: 26 April 2019 / Approved: 28 April 2019 / Online: 28 April 2019 (11:27:52 CEST)

How to cite: Sumner, M.; Das, I.; Pryor, E. K.; McCully, K. Effectiveness of 6-Ischemic Cuff Near Infrared Spectroscopy Mitochondrial Capactity Test. Preprints 2019, 2019040314. https://doi.org/10.20944/preprints201904.0314.v1 Sumner, M.; Das, I.; Pryor, E. K.; McCully, K. Effectiveness of 6-Ischemic Cuff Near Infrared Spectroscopy Mitochondrial Capactity Test. Preprints 2019, 2019040314. https://doi.org/10.20944/preprints201904.0314.v1

Abstract

Near-Infrared Spectroscopy (NIRS) has been used to measure muscle mitochondrial capacity. The current method requires as many as 22 short ischemic occlusions to generate a recovery curve for mitochondrial capacity. PURPOSE: To determine the effectiveness of using a 6-occlusion analysis protocol to study muscle mitochondrial capacity. METHOD: Two independent, unidentified data sets were analyzed (bicep n=48, forearm n=41) from previous studies using a NIRS device (Artinis, Ltd.). Both data sets had two recovery tests that included 22 ischemic occlusions. A recovery rate used to indicate mitochondrial capacity was calculated two different ways (simultaneously). Each sample was analyzed with a MATLAB program; with a curve-fit for the 22 ischemic occlusions and curve matching for the first six ischemic cuffs and an end resting value. The two resulting rate constants were compared using correlations, both for the two data sets, good and bad fitting data, using the best 5 of 6 points for the 6 cuff approach. RESULTS: The rate constants were not significantly different between the 22 cmuff and 6 cuff for the total data sets: bicep (1.43+0.32min-1, 1.44+0.35min-1, p=0.56), forearm (1.94+0.42min-1, 1.95+0.44min-1, p=0.76). The average bicep rate constants, when compared to each other, had an equation of y=1.07x-0.09, R2=0.90. The average forearm rate constants, when compared to each other, had an equation of 0.98x+0.02, R2=0.93. CONCLUSIONS: The 6-Cuff analysis provided the same results as the longer 22-cuff. The 6-cuff approach is both shorter in time and uses less ischemic occlusion periods, increasing the practicality of the NIRS mitochondrial capacity test.

Keywords

near infrared spectroscopy; NIRS; skeletal muscle; muscle metabolism; electrical stimulation

Subject

Biology and Life Sciences, Biochemistry and Molecular Biology

Comments (0)

We encourage comments and feedback from a broad range of readers. See criteria for comments and our Diversity statement.

Leave a public comment
Send a private comment to the author(s)
* All users must log in before leaving a comment
Views 0
Downloads 0
Comments 0


×
Alerts
Notify me about updates to this article or when a peer-reviewed version is published.
We use cookies on our website to ensure you get the best experience.
Read more about our cookies here.