Surface Plasmon Resonance (SPR) Computational Study of Hemoglobin (Hb) in Human Blood Detection

Version 1 : Received: 24 May 2018 / Approved: 24 May 2018 / Online: 24 May 2018 (09:01:27 CEST)
Version 2 : Received: 24 May 2018 / Approved: 25 May 2018 / Online: 25 May 2018 (10:02:27 CEST)

A peer-reviewed article of this Preprint also exists.

Widayanti; Abraha, K.; Bambang Setio Utomo, A. Computational Study of Sensitivity Enhancement in Surface Plasmon Resonance (SPR) Biosensors by Using the Inclusion of the Core-Shell for Biomaterial Sample Detection. Biosensors 2018, 8, 75. Widayanti; Abraha, K.; Bambang Setio Utomo, A. Computational Study of Sensitivity Enhancement in Surface Plasmon Resonance (SPR) Biosensors by Using the Inclusion of the Core-Shell for Biomaterial Sample Detection. Biosensors 2018, 8, 75.

Abstract

A theoretical analysis of haemoglobin (Hb) concentration detection is presented in this work with the objective of achieving more sensitive detection and monitoring low concentrations. Surface-enhanced SPR spectroscopy on silver nanoparticles was employed for recording Hb concentrations less than 10 g/L. In this paper, Fe3O4@Au core-shell, nanocomposite spherical nanoparticle consisting of a spherical Fe3O4 core covered by Au shell, was used as an active material for biomolecules detection in the Surface Plasmon Resonance (SPR)-based biosensor in the wavelength 632.8 nm. We present the simulation of detection amplification technique through Attenuated Total Reflection (ATR) spectrum in the Kretschmann configuration. The system consists of a four-layer material i.e prism/Ag/Fe3O4@Au+Hb/air. Dielectric function determination of the core-shell nanoparticle (Fe3O4@Au) and the composite (Fe3O4@Au+Hb) was done by applying the Effective Medium Theory approximation and the calculation of the reflectivity is carried out by varying the size of core-shell (r0). In this simulation, the refractive index of the BK7 prism is 1.51; the refractive index of Ag thin film is 0.13455+3.98651i with the thickness of 40 nm, and the refractive index of the composite is varied depending on the size of nanoparticle core-shell. Our results show that by varying the radius of the core and the shell thickness, the dip of the reflectivity (ATR) spectrum is shifted to the larger angle of incident light and the addition of core-shell in the conventional SPR-based biosensor leads to enhancement of the SPR biosensor sensitivity, for the core-shell radius 10 nm, the sensitivity increased by 1.35% for F = 0.1, and by 4.89% for F =0.8 compared to the sensitivity of the conventional SPR-based biosensor without core-shell addition.

Keywords

haemoglobin detection; SPR spectroscopy; biosensors; computer simulation; core-shell Fe3O4@Au

Subject

Chemistry and Materials Science, Biomaterials

Comments (0)

We encourage comments and feedback from a broad range of readers. See criteria for comments and our Diversity statement.

Leave a public comment
Send a private comment to the author(s)
* All users must log in before leaving a comment
Views 0
Downloads 0
Comments 0
Metrics 0


×
Alerts
Notify me about updates to this article or when a peer-reviewed version is published.
We use cookies on our website to ensure you get the best experience.
Read more about our cookies here.