Preprint
Article

Techno-Economic Feasibility of Hybrid Solar Photovoltaic and Battery Energy Storage Power System for a Soshanguve Mobile Cellular Base Station in South Africa

This version is not peer-reviewed.

Submitted:

24 April 2018

Posted:

24 April 2018

Read the latest preprint version here

A peer-reviewed article of this preprint also exists.

Abstract
Over the years, sustainability, impact on the environment, as well as the operation expenditure have been a major concern to the deployment of mobile cellular base stations worldwide. This is because the mobile cellular base stations are known to consume a high percentage of power within the mobile cellular network. Such energy consumption contributes to the emission of Greenhouse Gases (GHG) through the use of conventional diesel generating a set. As a result, the mobile cellular operators are faced with the dilemma of minimising the power consumption, GHG emission, and the operation cost, while improving the Quality of Service of the networks. In attempting to find a solution, this study presents the feasibility and simulation of a solar photovoltaic (PV) with battery hybrid power system (HPS) as a predominant source of power for a specific mobile cellular base station site situated in Soshanguve area of the city of Pretoria, South Africa. It also presents the technical development, showed the environmental advantage and cost benefits of using a solar PV-battery HPS to power a base station site of a 24 hrs daily load of 241.10 kWh/d and the peak load of 20.31 kW as compared to using the HPS of solar PV-diesel generating set-battery. The solar resource pattern for the city of Pretoria was collected from The National Aeronautics and Space Administration and modelled statistically. Thus, the statistical modelling done using solar radiation resource exposure characteristic patterns of Pretoria, South Africa, revealed an average annual daily solar radiation of 5.4645 Wh/m2/d and 0.605 clearness index. The simulation and the design were done using the Hybrid Optimization Model for Electric Renewables and Matlab/Simulink software. The simulation finding shows that the HPS of solar PV-battery combination has about 59.62 % saving on Net Present Cost, Levelized Cost of Energy, and 80.87% saving on Operating cost as against conventional BS powered with Gen Set-Battery.
Keywords: 
;  ;  ;  ;  ;  
Copyright: This open access article is published under a Creative Commons CC BY 4.0 license, which permit the free download, distribution, and reuse, provided that the author and preprint are cited in any reuse.

Downloads

4229

Views

665

Comments

0

Subscription

Notify me about updates to this article or when a peer-reviewed version is published.

Email

Prerpints.org logo

Preprints.org is a free preprint server supported by MDPI in Basel, Switzerland.

Subscribe

© 2025 MDPI (Basel, Switzerland) unless otherwise stated