Preprint Technical Note Version 1 Preserved in Portico This version is not peer-reviewed

Thoracic, Lumbar, and Sacral Pedicle Screw Placement Using Stryker-Ziehm Virtual Screw Technology and Navigated Stryker Cordless Driver 3: Technical Note

Version 1 : Received: 5 April 2018 / Approved: 5 April 2018 / Online: 5 April 2018 (05:53:24 CEST)

How to cite: Satarasinghe, P.; Hamilton, D.K.; Tarver, M.J.; Buchanan, R.J.; Koltz, M.T. Thoracic, Lumbar, and Sacral Pedicle Screw Placement Using Stryker-Ziehm Virtual Screw Technology and Navigated Stryker Cordless Driver 3: Technical Note. Preprints 2018, 2018040064. https://doi.org/10.20944/preprints201804.0064.v1 Satarasinghe, P.; Hamilton, D.K.; Tarver, M.J.; Buchanan, R.J.; Koltz, M.T. Thoracic, Lumbar, and Sacral Pedicle Screw Placement Using Stryker-Ziehm Virtual Screw Technology and Navigated Stryker Cordless Driver 3: Technical Note. Preprints 2018, 2018040064. https://doi.org/10.20944/preprints201804.0064.v1

Abstract

Object. Utilization of pedicle screws (PS) for spine stabilization is common in spinal surgery. With reliance on visual inspection of anatomical landmarks prior to screw placement, the free-hand technique requires a high level of surgeon skill and precision. Three-dimensional (3D) computer-assisted virtual neuronavigation improves the precision of PS placement and minimize steps. Methods. Twenty-three patients with degenerative, traumatic, or neoplastic pathologies received treatment via a novel three-step PS technique that utilizes a navigated power driver in combination with virtual screw technology. 1) Following visualization of neuroanatomy using intraoperative CT, a navigated 3-mm match stick drill bit was inserted at anatomical entry point with screen projection showing virtual screw. 2) Navigated Stryker Cordless Driver with appropriate tap was used to access vertebral body through pedicle with screen projection again showing virtual screw. 3) Navigated Stryker Cordless Driver with actual screw was used with screen projection showing the same virtual screw. One hundred and forty-four consecutive screws were inserted using this three-step, navigated driver, virtual screw technique. Results. Only 1 screw needed intraoperative revision after insertion using the three-step, navigated driver, virtual PS technique. This amounts to a 0.69% revision rate. One hundred percent of patients had intraoperative CT reconstructed images to confirm hardware placement. Conclusions. Pedicle screw placement utilizing the Stryker-Ziehm neuronavigation virtual screw technology with a three step, navigated power drill technique is safe and effective.

Keywords

pedicle screw; virtual technique; neuronavigation; spine; surgery; three-dimensional; stryker; ziehm

Subject

Medicine and Pharmacology, Surgery

Comments (0)

We encourage comments and feedback from a broad range of readers. See criteria for comments and our Diversity statement.

Leave a public comment
Send a private comment to the author(s)
* All users must log in before leaving a comment
Views 0
Downloads 0
Comments 0
Metrics 0


×
Alerts
Notify me about updates to this article or when a peer-reviewed version is published.
We use cookies on our website to ensure you get the best experience.
Read more about our cookies here.