Preprint
Article

This version is not peer-reviewed.

Atmospheric Dispersion and Spatial Hazard Assessment of a Hypothetical Chemical Release in an Industrial Area

Submitted:

22 November 2026

Posted:

25 November 2026

You are already at the latest version

Abstract
Chemical releases from storage facilities can generate distinct spatial exposure patterns under contrasting meteorological conditions, particularly in industrialized metropolitan areas. This study evaluated a hypothetical acetone release from an atmospheric storage tank in Paulínia, southeastern Brazil, by integrating atmospheric dispersion modeling, GIS-based spatial analysis, and multivariate statistics. Daytime and nighttime scenarios were simulated using representative meteorological conditions, and Acute Exposure Guideline Level (AEGL) zones were analyzed for their overlap with the industrial area. The daytime scenario produced higher release rates, greater released mass, and AEGL-1 and AEGL-2 distances 17.4% and 14.2% greater than at night, respectively. Conversely, the nighttime AEGL-1 zone showed substantially greater proportional overlap with the industrial park (75.8%) than the daytime zone (44.9%), demonstrating that plume extent alone does not determine spatial exposure. Principal Component Analysis explained 99.99% of the variability in the first two components, while K-means clustering identified similarity patterns primarily associated with hazard-zone characteristics. The integrated framework provides an objective basis for comparing chemical accident scenarios and supports preventive planning, emergency preparedness, and technological risk management in metropolitan industrial areas.
Keywords: 
;  ;  ;  ;  

1. Introduction

1.1. Chemical Accidents and Risk Management

Accidents involving hazardous chemicals pose a major challenge for technological risk management because they can significantly affect human health, the environment, and critical infrastructure. Accidental releases of toxic, flammable, or explosive substances can trigger fires, explosions, and atmospheric dispersion of contaminants; consequently, consequence analysis is essential for preventive planning, emergency agency preparedness, and risk management strategy development [1,2,3].
In Brazil, numerous petrochemical and chemical complexes are located within metropolitan areas, where industrial facilities, residential zones, highways, railways, and other strategic infrastructure coexist. This proximity heightens the vulnerability of the population and economic activities to chemical accidents, making it essential to conduct prior assessments of atmospheric dispersion scenarios and potentially affected areas. Such analyses inform the establishment of safety zones, land-use planning, and emergency response plans, helping mitigate the impacts of technological accidents in urbanized environments [2,4,5].

1.2. Associated Risks

Acetone (CAS 67-64-1) is a widely used chemical industry solvent for manufacturing resins, paints, adhesives, pharmaceuticals, and various chemical intermediates. Although it is less toxic than many other organic solvents, acetone has a high vapor pressure, a low boiling point, and high flammability. These characteristics enable rapid evaporation after a leak and increase the potential for toxic clouds and flammable atmospheres, so emergency scenarios require assessing atmospheric dispersion [6,7].
Assessing the consequences of leaks involving highly volatile liquids stored in atmospheric tanks relies on estimating the release rate, the formation of evaporating pools, and atmospheric dispersion. These processes determine the extent of hazard zones and the potential exposure of the population and neighboring facilities. Recent studies demonstrate the applicability of consequence models for assessing leaks from tanks containing volatile compounds, such as ethanol, benzene, and butyl acrylate, supporting their use to analyze scenarios involving acetone [8,9,10].

1.3. Atmospheric Dispersion

Analyzing chemical accident consequences relies on mathematical models that represent the release, evaporation, transport, and atmospheric dispersion of hazardous substances, based on their physicochemical properties, source characteristics, and meteorological conditions. These models estimate plume evolution and delineate zones that threaten human health and the environment, serving as essential tools for technological risk management [11,12,13].
Among the most widely used tools is ALOHA (Areal Locations of Hazardous Atmospheres), developed by the National Oceanic and Atmospheric Administration (NOAA) in partnership with the U.S. Environmental Protection Agency (EPA). The software simulates scenarios involving toxic releases, evaporating pools, fires, and explosions, and is widely used in consequence analysis, emergency planning, and industrial risk management [14]. Recent studies show its application to leaks from storage tanks, hazardous-material transport, and industrial facilities, highlighting its versatility in assessing accidental scenarios [9,10,15].
When assessing toxicological effects, ALOHA often uses Acute Exposure Guideline Levels (AEGLs), exposure thresholds representing varying degrees of severity in human health impacts, ranging from temporary discomfort to irreversible or potentially lethal consequences. These criteria inform the delineation of threat zones and the planning of protective measures and chemical emergency responses [14,16,17].

1.4. Influence of Weather Conditions

Meteorological conditions strongly shape the dispersion of atmospheric plumes from chemical accidents. Variables such as air temperature, wind speed and direction, atmospheric stability, relative humidity, and surface roughness simultaneously influence the substance’s evaporation rate, atmospheric contaminant transport, and the extent of hazard zones [18,19]. Recent studies demonstrate that changes in air temperature and wind speed can significantly alter evaporation rates and impact distances in scenarios involving leaks of volatile liquids stored in tanks [11].
Integrating atmospheric dispersion modeling with Geographic Information Systems (GIS) and spatial data allows for the identification of potentially exposed areas and the objective quantification of the affected area and the degree of overlap between hazard zones, industrial facilities, and urbanized areas; this supports land-use planning, technological risk management, and the development of chemical emergency response plans. This approach has been employed in studies of population vulnerability, the definition of evacuation routes, and the spatial assessment of accidents involving hazardous materials [5,15,20].
Although atmospheric dispersion modeling is well established in chemical accident consequence analysis [21,22], integrating contrasting meteorological scenarios, modeling and GIS spatial analysis [23,24], quantification of AEGL zone overlap with industrial areas, and multivariate techniques to synthesize similarity patterns across scenarios remains underexplored. This approach is particularly relevant for industrial complexes in metropolitan areas, where differences in plume extent and spatial orientation can produce distinct exposure patterns [24,25], influencing objective comparisons of risk scenarios and informing the planning of preventive measures [16].
In this context, this study simulates a hypothetical acetone leak from a storage tank at an important industrial complex in Paulínia, within the Immediate Geographic Region of the Campinas Area, one of Southeastern Brazil’s major metropolitan regions and home to an industrial complex strategically important to the Brazilian economy.

2. Methodological approach

2.1. Study Area

The study area corresponds to the Fazenda São Francisco Industrial Park in Paulínia (São Paulo state), within the Campinas Immediate Geographic Region (IGR). The development includes facilities for producing specialty chemicals, oxygenated solvents, and chemical intermediates. The complex is in the Atibaia River basin and is part of the Piracicaba, Capivari, and Jundiaí Rivers Water Resources Management Unit (UGRHI-5) (CBH-PCJ 2020). According to the São Paulo State Department of Highways, its location benefits from proximity to the Anhanguera (SP-330), Dom Pedro I (SP-065), Professor Zeferino Vaz (SP-332), and Governador Adhemar Pereira de Barros (SP-340) highways, as well as Viracopos International Airport (Figure 1).
This scenario analyzes a hypothetical release of acetone (CAS 67-64-1) from a vertical atmospheric cylindrical tank at the industrial complex. Acetone was selected from the substance library in ALOHA version 5.4.7 [14]. We conducted a literature search on the CAPES CAFe Journal Portal and Google Scholar using the search strategy “ALOHA” AND “Hazardous Atmospheres”.
Meteorological data were obtained via the Brazilian Air Force Command’s Meteorology Network (REDEMET/DECEA) API. After obtaining the authentication key (API Key), the data were automatically queried and downloaded using a Python script executed in Spyder, utilizing the requests, pandas, and openpyxl libraries [26]. To represent the study area’s atmospheric conditions, we defined two representative meteorological scenarios for July 31, 2026: daytime (08:00–18:00; representative time: 14:00) and nighttime (20:00–06:00; representative time: 03:00) [14,18,19] (Table 1).
In both scenarios, the emission source parameters remained constant: a vertical atmospheric cylindrical tank with a volume of 5,655 m³ (20 m in diameter and 18 m in height), containing approximately 3,918 t of acetone at 80% fill capacity. The leak was simulated through a circular orifice 0.05 m in diameter, located 1.0 m above the tank bottom, resulting in an evaporating pool on the concrete floor that lasted up to 1 hour. The simulations utilized the ALOHA Gaussian model to represent the dispersion of a toxic acetone vapor cloud (TVC). Threat zones were defined based on AEGL values for a 60-minute exposure (AEGL-3 = 5,700 ppm; AEGL-2 = 3,200 ppm; AEGL-1 = 200 ppm), and wind direction confidence limits (CL) were also established to account for the uncertainty associated with the directional variability of atmospheric flow [14,27].

3. Results

3.1. Characterization of Atmospheric Dispersion

According to the 2022 Demographic Census, the Campinas Immediate Geographic Region, comprising the municipalities of Campinas, Paulínia, Cosmópolis, Holambra, Hortolândia, Jaguariúna, Monte Mor, Nova Odessa, Santo Antônio de Posse, Sumaré, and Valinhos, has an urban population of 3,004,186 inhabitants distributed across an area of 105,829.7 ha (1,058.30 km²), with an average population density of 98.96 inhabitants/ha per census tract [28].
The meteorological scenarios for July 31, 2026, showed differences in wind patterns between daytime and nighttime (Figure 2a and Figure 2b). During the daytime (14:00), winds from the ENE quadrant predominated, with a mean direction of approximately 80°, a speed of 3.1 m s⁻¹, and greater directional variability. At night (03:00), winds remained predominantly in the NE quadrant, with a mean direction of approximately 45°, a speed of 2.6 m s⁻¹, and lower angular dispersion, indicating greater stability in the atmospheric flow direction.
Simulations using the Gaussian model revealed differences in acetone vapor plume dispersion between daytime and nighttime scenarios, while keeping emission source parameters constant. In the daytime scenario (DTTZ), the higher air temperature (26 °C) resulted in a vapor pressure of 0.32 atm and a saturation concentration of 317,423 ppm (31.7%), yielding a maximum average release rate of approximately 412 kg min⁻¹ and a total released mass of 18,377 kg over a one-hour simulation. The evaporating pool reached a diameter of approximately 64.9 m, a value equivalent to the extent of the AEGL-3 zone, indicating that the highest concentrations remained confined to the vicinity of the emission source. The AEGL-2 and AEGL-1 zones extended to 88.7 m and 923.5 m, respectively (Figure 3c).
In the nighttime scenario (NTTZ), the temperature reduction to 16 °C lowered the acetone vapor pressure to 0.20 atm and the saturation concentration to 203,896 ppm (20.4%), reducing the maximum average release rate to approximately 283 kg min⁻¹ and the total mass released to 11,627 kg over one hour. The evaporating pool had a diameter of approximately 66.8 m, while the effectively represented threat zones reached 77.7 m for AEGL-2 and 786.4 m for AEGL-1 (Figure 3c). Although the model calculated a theoretical range of 57.6 m for AEGL-3, this zone was not represented because its length was less than the maximum diameter of the evaporating pool (66.8 m), a condition under which ALOHA considers dispersion estimates unreliable.
In comparison, the DTTZ scenario had a higher emission rate, released more mass, and produced wider hazard zones. Compared with the NTTZ, the AEGL-2 and AEGL-1 zones were approximately 14.2% and 17.4% larger, respectively. Furthermore, only the DTTZ scenario presented a representable AEGL-3 zone, as the theoretical range in the NTTZ scenario was smaller than the maximum diameter of the evaporating pool. This indicates that higher air temperature influenced acetone volatilization more than differences in wind speed and directional variability, thereby extending the plume’s reach. Notably, the confidence limit (CL) for the DTTZ and NTTZ scenarios can vary between NE-SW and NE-S, respectively (Figure 3c).
Table 2 shows that the DTTZ scenario had the largest hazard zones, with total areas of 8.26 ha (AEGL-1), 0.76 ha (AEGL-2), and 0.59 ha (AEGL-3). In the NTTZ scenario, the AEGL-1 and AEGL-2 areas decreased to 6.65 ha and 0.70 ha, respectively, while AEGL-3 was not represented. Despite the smaller plume extent at night, the overlap of AEGL-1 with the Fazenda São Francisco Industrial Park increased from 44.9% (3.71 ha) to 75.8% (5.04 ha). The AEGL-2 zone remained entirely within the industrial area in both scenarios (100%). In comparison, the area covered by the CL increased from 45.8% (23.97 ha) to 47.3% (28.40 ha), indicating a greater incidence of the plume over the industrial area at night due to the prevailing wind direction.

3.2. Multivariability of Scenarios

Table 3 presents the correlation matrix for the variables used in the Factorial PCA. A strong positive correlation was observed between total area (ln_Total) and incident area (ln_Ind) for the Fazenda São Francisco Industrial Park (r = 0.993), indicating that an increase in the extent of the hazard zones was accompanied by a larger affected area within the industrial park. Conversely, the percentage of overlap showed a negative correlation with both the total area (r = −0.894) and the incident area (r = −0.839), indicating that smaller hazard zones can show a higher proportional incidence within the industrial area. PCA is justified by the strong association between the variables and the distinct patterns of spatial variability in hazard zones and their overlap with the industrial park.
Bartlett’s test of sphericity [29] indicated a significant correlation between the variables (χ² = 26.94; p < 0.001), supporting the analysis. PCA explained 99.99% of the data variability within the first two components.
Table 4 shows that PC1 was explained in a balanced manner by total area (35.03%), incident area (33.75%), and overlap percentage (31.22%), characterizing a gradient associated with threat-zone magnitude. In turn, PC2 was predominantly determined by the overlap percentage (66.37%), followed by the incident area (26.83%), while the total area showed a low contribution (6.80%); this indicates that this component primarily represents the relative incidence of the plume over the Fazenda São Francisco Industrial Park.
The elbow method indicated that a three-cluster solution best represented the data structure, as shown by the reduction in inertia between two and three groupings and the curve’s stabilization at higher k values (Figure 3a). In the Factorial PCA, the first two components explained 99.99% of the total variance; Factor 1 accounted for 93.97% and was associated primarily with total areas (ln_Total), incident areas (ln_Ind), and overlap areas (%) at the Fazenda São Francisco Industrial Park. In contrast, Factor 2 explained 6.02% and was related to the overlap percentage (%) and total areas (ln_Total). The perceptual map revealed three distinct groupings (Figure 3b): Cluster 1 comprised DTTZ–AEGL-2, NTTZ–AEGL-2, and NTTZ–AEGL-1; Cluster 2 grouped DTTZ–LC and NTTZ–CL; and Cluster 3 was composed exclusively of DTTZ–AEGL-1, indicating that the groupings were determined primarily by the characteristics of the threat zones, rather than solely by the daytime or nighttime period.

4. Discussion

4.1. Influence of Meteorological Conditions on Acetone Dispersion

The results show that the daytime scenario, characterized by higher temperatures and, consequently, higher acetone vapor pressure, exhibited a higher evaporation rate, greater mass release, and a wider extent of hazard zones than the nighttime scenario. This behavior is consistent with acetone’s high volatility; its vapor pressure rises with temperature, thereby promoting mass transfer from the liquid phase to the atmosphere. Similar results were observed in simulations of ethanol and benzene leaks, where higher temperatures led to increased release rates and expanded hazard zones. These findings confirm that, for highly volatile liquids stored in atmospheric tanks, meteorological variations can significantly alter release rates and plume dispersion [2,6,7,9,10].
When interpreting these results, distinguish atmospheric stability from the source-strength response. Under otherwise comparable source conditions, stable atmospheric conditions generally suppress vertical turbulent mixing and may sustain elevated downwind concentrations, whereas unstable conditions promote stronger turbulent dilution [11,14,19]. In the present simulations, however, both scenarios were assigned stability class E, precluding attribution of the observed differences to a daytime–nighttime stability-class contrast. Instead, the contrasting plume behavior reflects the combined influence of meteorological conditions on acetone volatilization and subsequent atmospheric transport. For highly volatile liquids, temperature-dependent vapor pressure can substantially affect source strength following a spill, while wind conditions govern transport and dilution of the resulting vapor cloud. Therefore, the greater plume extent observed under daytime conditions should be interpreted as the outcome of coupled source-term and dispersion processes rather than as an isolated effect of atmospheric stability [2,11,14,18].

4.2. Influence of Wind and Spatial Analysis on Industrial Exposure

Although the daytime scenario produced more extensive hazard zones, the nighttime scenario showed a higher percentage of AEGL-1 zone overlap with the Fazenda São Francisco Industrial Park. This result shows that the severity of a chemical accident depends not only on the plume’s travel distance but also on the wind’s spatial orientation relative to exposed receptors. Thus, shorter-range scenarios can pose a greater risk to specific infrastructure when the prevailing flow direction favors interception, highlighting the importance of using representative meteorological scenarios in consequence analyses [2,4].
From a risk management perspective, these results show that consequence assessment must consider plume magnitude and spatial distribution simultaneously. In industrial areas located within metropolitan regions, slight variations in wind direction can significantly alter which facilities are potentially exposed, thereby influencing strategies for evacuation, isolation, response team positioning, and the definition of safety zones [11,14].
Integrating ALOHA with Geographic Information Systems (GIS) was a key methodological advancement, enabling quantification not only of AEGL zone reach but also of the areas actually affected and the extent to which these areas overlapped with the Fazenda São Francisco Industrial Park. This approach revealed that minor differences in meteorological conditions significantly altered the spatial distribution of hazard zones. This result would have been difficult to identify through travel-distance analysis alone. Recent studies show that integrating atmospheric modeling and GIS enhances consequence analysis by supporting technological risk management, environmental licensing, and land-use planning [5,15,20,30,31,32].

4.3. Applicability of Multivariate Analysis

PCA provided an exploratory framework for synthesizing the spatial relationships among the simulated threat zones. The correlation structure revealed substantial redundancy among the spatial metrics, particularly between total hazard-zone area and the area overlapping the industrial park. Moreover, because the overlap percentage is mathematically derived from the relationship between incident and total areas, the variables are not fully independent. Accordingly, PCA should be interpreted here as an exploratory ordination technique for summarizing the spatial structure of a small set of modeled scenarios rather than as an inferential dimensionality-reduction procedure. The concentration of nearly all variance in the first two components therefore primarily reflects the strong structural dependence among the spatial metrics [33,34,35,36,37,38].
Within this exploratory framework, the components provided a useful distinction between hazard-zone magnitude and relative spatial incidence over the industrial area. This distinction matters because plume extent and receptor-specific exposure do not necessarily vary proportionally. The clustering pattern also highlighted similarities and differences among threat zones under different meteorological conditions, suggesting that distinct exposure thresholds may respond differently to changes in atmospheric transport and plume orientation. This behavior is consistent with atmospheric dispersion’s dependence on interactions among source characteristics, physicochemical properties, and meteorological conditions [11,12,14].
K-means clustering complemented the ordination by grouping modeled outcomes by spatial characteristics rather than by daytime or nighttime classification alone. Given the limited number of observations and the structural dependence among the variables, however, these clusters should be regarded as descriptive patterns rather than statistically generalizable groups. In this context, the multivariate approach complements GIS-based analysis by concisely representing similarities among modeled spatial outcomes. Integrating dispersion modeling, spatial analysis, and exploratory multivariate techniques can therefore improve scenario comparison and support the interpretation of information relevant to technological risk management and emergency planning [35,39,40].

5. Conclusions

The study simulates a hypothetical acetone leak from an atmospheric tank within an industrial complex, integrating atmospheric dispersion modeling with ALOHA, spatial analysis via GIS, and multivariate techniques. The results showed that the daytime scenario, characterized by higher temperatures and, consequently, higher acetone vapor pressure, had a higher evaporation rate, greater released mass, and wider AEGL-1 and AEGL-2 hazard zones.
However, the greatest plume extent did not necessarily correspond to the greatest spatial impact on the industrial area. Despite shorter propagation distances at night, the AEGL-1 zone overlapped more with the Fazenda São Francisco Industrial Park, highlighting that wind direction can be as important as plume magnitude in determining exposure for specific receptors.
Integrating ALOHA, GIS, and multivariate techniques enabled objective quantification of exposure within the industrial area and synthesis of the spatial patterns of the simulated scenarios. PCA explained 99.99% of the variability in the first two components; combined with K-means clustering, it revealed high similarity between the AEGL-2 zones in the daytime and nighttime scenarios, whereas the AEGL-1 zone showed greater sensitivity to meteorological differences.
Study limitations include the use of a hypothetical scenario, simplifications inherent to the Gaussian model implemented in ALOHA, and the exclusion of factors such as building effects, temporal variability in meteorological conditions, topography, and operational changes during the leak. Furthermore, the analysis focused exclusively on acetone dispersion and did not address fire or explosion scenarios or cascading effects. Future recommendations include using long-term meteorological datasets; integrating modeling with data on population, critical infrastructure, and vulnerability indicators; and assessing multiple hazardous substances, fire and explosion scenarios, and three-dimensional atmospheric dispersion models that more realistically represent the effects of urban roughness and buildings.

Author Contributions

Author Contributions: Conceptualization, A.T.S.F., N.O. and J.A.S.; methodology, A.T.S.F., N.O. and J.A.S.; software, A.T.S.F.; validation, N.O. and J.A.S.; formal analysis, A.T.S.F.; investigation, A.T.S.F.; resources, N.U.W.; data curation, A.T.S.F.; writing—original draft preparation, A.T.S.F.; writing—review and editing, A.T.S.F., N.O., J.A.S. and N.U.W.; visualization, A.T.S.F.; supervision, N.O., J.A.S. and N.U.W.; project administration, N.U.W. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by the Institute of Energy and Nuclear Research (IPEN)/National Nuclear Energy Commission (CNEN)–Agribusiness Research Development Foundation (FUNDEPAG), grant number 17/2026 (project number 2024.07.IPEN.67); the National Council for Scientific and Technological Development (CNPq), grant number 350056/2026-9; the São Paulo Research Foundation (FAPESP), grant number 2021/04334-7; and the National Institute of Science and Technology of Radiation in Health (INCT-INTERAS), grant number 406761/2022-1.

Data Availability Statement

The supplementary material supporting the findings of this study is publicly available in Zenodo at https://doi.org/10.5281/zenodo.22286619.

Acknowledgments

The authors acknowledge institutional support from the Institute of Energy and Nuclear Research (IPEN), managed by the National Nuclear Energy Commission (CNEN), and the Federal University of ABC (UFABC). The authors also thank the Editor-in-Chief, Associate Editor, and anonymous reviewers for their comments and suggestions. The authors have reviewed and edited the output and take full responsibility for the content of this publication.

Conflicts of Interest

The authors declare no conflicts of interest. The funders had no role in the design of the study; in the collection, analysis, or interpretation of data; in the writing of the manuscript; or in the decision to publish the results.

References

  1. Khan, F.I.; Abbasi, S.A. Major Accidents in Process Industries and an Analysis of Causes and Consequences. J. Loss Prev. Process Ind. 1999, 12, 361–378. [Google Scholar] [CrossRef]
  2. CCPS Guidelines for Chemical Process Quantitative Risk Analysis, 2nd ed.; Wiley: New York, 2010; ISBN 9780816907205.
  3. Glova Végsöová, O.; Grabara, J.K. Assessing Crisis Management Tools for Sustainability of Industrial Safety. Appl. Sci. 2024, 14, 10037. [Google Scholar] [CrossRef]
  4. EPA Risk Management Program Guidance for Offsite Consequence Analysis; United States Environmental Protection Agency, 2009.
  5. Švec, P.; Skřínský, J. Application of GIS for the Control of Major Accident Hazards. Geosci. Eng. 2022, 68, 151–157. [Google Scholar] [CrossRef]
  6. Hansen, H.; Wilbur, S.B. Toxicological Profile for AcetoneMay 1994. 1994. [Google Scholar]
  7. Luttrell, W.E.; LaGrow, A.L. Acetone. J. Chem. Health Saf. 2014, 21, 29–31. [Google Scholar] [CrossRef]
  8. Saloglu, D.; Dertli, H.; Mohammadi, M.; Mohammadi, M. Emission Rates, ALOHA Simulation and Box-Behnken Design of Accidental Releases in Butyl Acrylate Tank - Case Study. Prod. Eng. Arch. 2022, 28, 346–358. [Google Scholar] [CrossRef]
  9. Mi Zhou Chao Xu, X.X.X.L. Accident Consequence Assessment of Benzene Leakage from Storage Tank in a Chemical Park in Bengbu City, China. Process Saf. Prog. 2023, 42, 440–447. [CrossRef]
  10. Sinan Doğan, M.E.Ö. Consequence Modeling and Analysis of Ethanol Leakage from Storage Tank Using the ALOHA Program. J. Amasya Univ. Inst. Sci. Technol. 2024, 5, 49–59. [Google Scholar] [CrossRef]
  11. Hanna, S.R.; Briggs, G.A.; Hosker, R.P.J. Handbook on Atmospheric Diffusion; (No Title) 1982.
  12. Turner, D.B. Workbook of Atmospheric Dispersion Estimates; US Department of Health, Education, and Welfare, National Center for Air …, 1967; Vol. 26. [Google Scholar]
  13. Chakraborty, J. Unregulated and Unequal: Environmental Justice and the GKN Aerospace Incident in Orange County, California. Environ. Justice 2024, 19394071261466182. [Google Scholar]
  14. Jones, R.; Lehr, W.; Simecek-Beatty, D.; Reynolds, M. ALOHA®(Areal Locations of Hazardous Atmospheres) 5.4. 4: Technical Documentation. 2013. [Google Scholar]
  15. Anjana, N.S.; Amarnath, A.; Harindranathan Nair, M. V. Toxic Hazards of Ammonia Release and Population Vulnerability Assessment Using Geographical Information System. J. Environ. Manag. 2018, 210, 201–209. [Google Scholar] [CrossRef]
  16. Bruckner, J. V.; Keys, D.A.; Fisher, J.W. The Acute Exposure Guideline Level (AEGL) Program: Applications of Physiologically Based Pharmacokinetic Modeling. J. Toxicol. Environ. Health A 2004, 67, 621–634. [Google Scholar] [CrossRef]
  17. Woodall, G.M., Jr.; Kobylewski-Saucier, S.E.; Shaffer, R.M.; Luke, A.M.; Carlson, L.M. Comparative Review of Human Health Reference Values of the United States. Toxicol. Sci. 2025, 207, 1–19. [Google Scholar] [CrossRef]
  18. Gifford, F.A. Use of Routine Meteorological Observations for Estimating Atmospheric Dispersion. Nucl. Saf. 1961, 2, 47–51. [Google Scholar]
  19. Pasquill, F. The Estimation of the Dispersion of Windborne Material. Meteoro. Mag. 1961, 90, 20–49. [Google Scholar]
  20. Bondžić, J.; Sremački, M.; Popov, S.; Mihajlović, I.; Vujić, B.; Petrović, M. Exposure to Hazmat Road Accidents – Toxic Release Simulation and GIS-Based Assessment Method. J. Environ. Manag. 2021, 293, 112941. [Google Scholar] [CrossRef]
  21. Lopes, T.J.; dos Santos, N.L.; da Silva Júnior, A.H.; Correio, A. da S. Statistical Analysis of the Result of Hypothetical Accident Scenarios with Leakage of Chlorine Gas Obtained by Simulation Using the Software ALOHA ®. Rev. Cienc. Exatas E Nat. 2016, 18. [Google Scholar] [CrossRef]
  22. Putra, M.R. Analisis Dispersi Emisi Hidrokarbon Pada Onshore Receiving Facilities Menggunakan ALOHA 5.4.5. J. Tek. ITS 2016, 5. [Google Scholar] [CrossRef]
  23. Kolsaman, P. Risk Assessment and Geospatial Mapping of Ammonia Transportation Hazards: A Case Study of Thungsong, Thailand. ASEAN J. Sci. Technol. Rep. 2025, 28, e254894. [Google Scholar] [CrossRef]
  24. Liu, J.; Tan, L.; Ma, Y. An Integrated Risk Assessment Method for Urban Areas Due to Chemical Leakage Accidents. Reliab. Eng. Syst. Saf. 2024, 247, 110091. [Google Scholar] [CrossRef]
  25. Gołębiowski, M.; Majder-Łopatka, M. Impact of Meteorological Conditions and Emission Type on the Dispersion of Chlorine in Open Terrain. Zesz. Nauk. SGSP/Szkoła Główna Służby Pożarniczej 2025, 85–97. [Google Scholar] [CrossRef]
  26. Spyder Project Contributors Spyder: The Scientific Python Development Environment (Version 6.1.2) 2025.
  27. Simecek-Beatty, D. ALOHA®(Areal Locations of Hazardous Atmospheres) 5.4. 4: Technical Documentation. 2013. [Google Scholar]
  28. IBGE Censo Demográfico 2022; Rio de Janeiro, 2023.
  29. Bartlett, M.S. A Note on the Multiplying Factors for Various Χ2 Approximations. J. R. Stat. Soc. Ser. B Stat. Methodol. 1954, 16, 296–298. [Google Scholar] [CrossRef]
  30. Burrough, P.A.; McDonnell, R.A.; Lloyd, C.D. Principles of Geographical Information Systems; Oxford University Press, USA, 2015; ISBN 0198742843. ISSN 0198742843. [Google Scholar]
  31. Longley, P.A.; Goodchild, M.F.; Maguire, D.J.; Rhind, D.W. Geographic Information Science and Systems, 4th ed.; Wiley: Hoboken, NJ, 2015; ISBN 978-1-119-12845-8. [Google Scholar]
  32. de Smith, M.J.; Goodchild, M.F.; Longley, P.A. Geospatial Analysis 6th Edition, 2018 - de Smith, Goodchild, Longley and Colleagues; 2018; ISBN 9781912556038. [Google Scholar]
  33. Jolliffe, I. Principal Component Analysis. In International Encyclopedia of Statistical Science; Springer, 2025; pp. 1945–1948. [Google Scholar]
  34. Abdi, H.; Williams, L.J. Principal Component Analysis. Wiley Interdiscip. Rev. Comput. Stat. 2010, 2, 433–459. [Google Scholar] [CrossRef]
  35. Fávero, L.P.; Belfiore, P. Manual de Análise de Dados: Estatística e Machine Learning Com Excel®, SPSS®, Stata®, R® e Python®, 2nd ed.; GEN LTC: Rio de Janeiro, RJ, Brasil, 2024; ISBN 9788595159921. [Google Scholar]
  36. Fávero, L.; Fávero, P. Análise de Dados: Técnicas Multivariadas Exploratórias Com SPSS e STATA; Elsevier Brasil: Rio de Janeiro, RJ, Brasil, 2017; ISBN 8535280669. ISSN 8535280669. [Google Scholar]
  37. Hair, J.F., Jr.; Fávero, L.P. Multilevel Modeling for Longitudinal Data: Concepts and Applications. RAUSP Manag. J. 2019, 54, 459–489. [Google Scholar] [CrossRef]
  38. Fávero, L.P.L.; Belfiore, P.P.; da Silva, F.L.; Chan, B.L.P.P.-R.; de, J. Análise de Dados: Modelagem Multivariada Para Tomada de Decisões; Elsevier: Rio de Janeiro, RJ, Brasil, 2009. [Google Scholar]
  39. Jain, A.K. Data Clustering: 50 Years beyond K-Means. Pattern Recognit. Lett. 2010, 31, 651–666. [Google Scholar] [CrossRef]
  40. Hartigan, J.A.; Wong, M.A. Algorithm AS 136: A K-Means Clustering Algorithm. Appl. Stat. 1979, 28, 100. [Google Scholar] [CrossRef]
Figure 1. Fazenda São Francisco Industrial Park (Pq. Ind. Fz. S. F.), Paulínia, Campinas IGR, SP.
Figure 1. Fazenda São Francisco Industrial Park (Pq. Ind. Fz. S. F.), Paulínia, Campinas IGR, SP.
Preprints 245776 g001
Figure 2. (a and b). Daytime and nighttime meteorological scenarios. The blue areas represent the average direction and speed of the prevailing wind, as well as wind directional variability (REDEMET/DECEA). (c) Acetone vapor plume hazard zones for the daytime (DTTZ, July 31, 2026, 14:00) and nighttime (NTTZ, July 31, 2026, 03:00) scenarios, classified as: AEGL-3 = 5,700 ppm; AEGL-2 = 3,200 ppm; AEGL-1 = 200 ppm. CL represents the wind direction confidence limit. Pq. Ind. Fz. S. F. = Fazenda São Francisco Industrial Park.
Figure 2. (a and b). Daytime and nighttime meteorological scenarios. The blue areas represent the average direction and speed of the prevailing wind, as well as wind directional variability (REDEMET/DECEA). (c) Acetone vapor plume hazard zones for the daytime (DTTZ, July 31, 2026, 14:00) and nighttime (NTTZ, July 31, 2026, 03:00) scenarios, classified as: AEGL-3 = 5,700 ppm; AEGL-2 = 3,200 ppm; AEGL-1 = 200 ppm. CL represents the wind direction confidence limit. Pq. Ind. Fz. S. F. = Fazenda São Francisco Industrial Park.
Preprints 245776 g002
Figure 3. (a) Elbow method for determining the optimal number of clusters (k). (b) Perceptual map from factorial PCA with K-means clustering for daytime (DTTZ) and nighttime (NTTZ) scenarios. Colors represent the clusters, vectors represent the analyzed variables, and “x” symbols represent the centroids.
Figure 3. (a) Elbow method for determining the optimal number of clusters (k). (b) Perceptual map from factorial PCA with K-means clustering for daytime (DTTZ) and nighttime (NTTZ) scenarios. Colors represent the clusters, vectors represent the analyzed variables, and “x” symbols represent the centroids.
Preprints 245776 g003
Table 1. Meteorological input parameters adopted for the daytime and nighttime scenarios in the ALOHA atmospheric dispersion simulations.
Table 1. Meteorological input parameters adopted for the daytime and nighttime scenarios in the ALOHA atmospheric dispersion simulations.
Parameter Daytime scenario Nighttime scenario
Date July 31 July 31
Air temperature 26 °C 16 °C
Relative humidity 55% 85%
Wind speed 3.1 m s⁻¹ 2.6 m s⁻¹
Wind direction ENE NE
Wind measurement height 10 m 10 m
Surface roughness Urban or Forest Urban or Forest
Cloud cover 05/out 05/out
Atmospheric stability class E E
Inversion height No Inversion No Inversion
Table 2. Total area of the hazard zones and area overlapping the Fazenda São Francisco Industrial Park (Ind) under daytime (DTTZ) and nighttime (NTTZ) scenarios. CL = concentration limit; Ind = area overlapping the Fazenda São Francisco Industrial Park; DTTZ = daytime threat zone; NTTZ = nighttime threat zone.
Table 2. Total area of the hazard zones and area overlapping the Fazenda São Francisco Industrial Park (Ind) under daytime (DTTZ) and nighttime (NTTZ) scenarios. CL = concentration limit; Ind = area overlapping the Fazenda São Francisco Industrial Park; DTTZ = daytime threat zone; NTTZ = nighttime threat zone.
Zone DTTZ NTTZ
Total (ha) Ind (ha) % Total (ha) Ind (ha) %
CL 52,32 23,97 45,81 60,08 28,40 47,28
AEGL-1 8,26 3,71 44,94 6,65 5,04 75,75
AEGL-2 0,76 0,76 100,00 0,70 0,70 100,00
AEGL-3 0,59 0,59 100,00 - - -
Table 3. Correlation matrix between the PCA-Factor variables.
Table 3. Correlation matrix between the PCA-Factor variables.
Threat zones ln_Total (ha) ln_Ind (ha) Sobreposição (%)
ln_Total (ha) 1,000 0,993 -0,894
ln_Ind (ha) 0,993 1,000 -0,839
Sobreposição (%) -0,894 -0,839 1,000
Table 4. Percentage contribution of the variables to the principal components (PC1 and PC2) of the Factorial PCA.
Table 4. Percentage contribution of the variables to the principal components (PC1 and PC2) of the Factorial PCA.
Threat zones PC1 PC2
ln_Total (ha) 35,028 6,797
ln_Ind (ha) 33,748 26,833
Overlap (%) 31,223 66,370
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.
Copyright: This open access article is published under a Creative Commons CC BY 4.0 license, which permit the free download, distribution, and reuse, provided that the author and preprint are cited in any reuse.