Submitted:
23 November 2026
Posted:
25 November 2026
You are already at the latest version
Abstract
Per- and polyfluoroalkyl substances (PFASs) are persistent, bioaccumulative, and hazardous to health, so selective and sensitive analytical methods are needed to clarify the state of PFAS contamination. However, conventional PFAS analytical methods have several drawbacks, including complex and time-consuming sample preparation procedures and the need for relatively large sample volumes and organic solvents. This study aimed to develop a fully automated online method combining in-tube solid–phase microextraction with liquid chromatography–tandem mass spectrometry (IT-SPME/LC-MS/MS) to determine PFASs in environmental and drinking water samples. Three PFASs were efficiently extracted and concentrated by IT–SPME using a Supel-Q PLOT capillary, then separated and detected by LC–MS/MS within 3 min. This method showed good linearity (R2 ≥ 0.9998) over 1–250 pg/mL, detection limits of 0.06–0.23 pg/mL, excellent reproducibility (< 8.3%), and accuracy (95–109%). Recoveries of PFASs added to samples were 93–107%, with minimal matrix effects. Extraction, concentration, separation, detection, and data analysis were automated online simply by installing a capillary in an autosampler, enabling continuous analysis of multiple samples. The method required virtually no complicated sample preparation or harmful organic solvents and showed no carryover. It is expected to be useful for monitoring PFAS contamination in water.
Keywords:
per- and polyfluoroalkyl substances
; environmental water
; drinking water
; in-tube solid-phase microextraction
; liquid chromatography-tandem mass spectrometry
; fully automated online analysis system
1. Introduction
Environmental pollutants that are stable, persistent, and bioaccumulative are classified as persistent organic pollutants (POPs), and their toxicity is recognized as a threat to ecosystems, animals, and human health. Per- and polyfluoroalkyl substances (PFASs) possess a carbon-fluorine (C-F) bonds, one of the strongest covalent bonds in organic chemistry [1-4]. Because of the strong polarization caused by the large difference in electronegativity between carbon and fluorine, PFASs are highly stable and resistant to thermal decomposition, photodecomposition, and hydrolysis, so they degrade poorly in the natural environment [2,5,6,7,8,9]. In addition, PFASs are amphiphilic compounds whose molecules containing a hydrophobic fluorinated carbon skeleton and hydrophilic functional groups such as carboxylic and sulfonic acids [1,2,10,11,12].Their surfactant properties, resulting from acid dissociation and a relatively high n-octanol-water partition coefficient, give them water-repellent and surface-protective effects [7]. Due to these useful physicochemical properties, including heat resistance, water resistance, and chemical resistance, PFASs have been widely used from the 1940s to the present in commercial and industrial products such as carpets, textile impregnating agents, waterproof clothing, cookware, food packaging, household detergents, cosmetics, adhesives, fluorine-based waxes, insecticides, foam fire extinguishers, plastics and rubber, insulation materials, electroplating, semiconductors, electronic equipment, and explosives [1,2,3,6,7,13,14,15,16,17,18,19,20,21,22,23,24,25,26]. As a result of their long–term use in thousands of products worldwide, persistent PFASs are widely now distributed POPs in the environment, and concerns about their health effects have made them an urgent environmental and public health issue [17].
PFASs are released into the environment through various anthropogenic routes, such as wastewater from households and industrial production facilities, and landfill leachate. They contaminate air, groundwater, river water, seawater, sediments, soil, drinking water, plants, grains, fruits, and other food sources [7,19,27,28,29,30,31], and they are taken up by and accumulate in wildlife and the human body [7,32,33]. This bioaccumulation poses a direct threat to ecosystems and a potential risk to humans, who are at the top of the food chain [13,14,15,34,35,36,37]. Even trace amounts of PFAS in the environment may therefore cause various toxic effects in organisms, including carcinogenicity, neurotoxicity, immunotoxicity, reproductive toxicity, developmental toxicity, and endocrine disruption [13,15,18,20,32,34,38,39]. Because ingestion of PFAS–contaminated drinking water and food has been identified as a major route of human exposure, monitoring water sources such as tap water and river water, together with food quality control, is important for understanding the sources, accumulation, transport, and distribution of PFASs and for assessing health risks. Accurate and efficient PFAS analysis methods are therefore necessary [3,7,16,18,20,21,35].
Currently, perfluorooctanesulfonic acid (PFOS), perfluorooctanoic acid (PFOA), and perfluorohexanesulfonic acid (PFHxS) are listed under the Stockholm Convention on POPs, and their use is restricted [2,14,18,40,41]. In 2004, the U.S. Environmental Protection Agency (US EPA) set maximum contaminant levels in drinking water of 4 ng/L for PFOS and PFOA, and 10 ng/L for PFHxS [2]. In response to such regulations, various guidelines and reference methods have been developed, and several US EPA methods are widely applied to PFAS analysis in various environmental matrices [6,7,19]. However, the method must be selected according to the sample type, such as drinking water, surface water, groundwater, wastewater, sludge, or soil [6,19]. Furthermore, as analytical instruments reach lower detection limits for PFASs, they also detect more interfering matrix substances, which can both suppress and enhance the analyte signal [19]. The more complex the matrix, the more likely such interference is to affect the analysis, which may require additional sample cleanup, cause loss of some sample information, and reduce recoveries [19]. In addition, because PFASs are ubiquitous, background contamination from the reagents, instruments, and equipment used in the analysis is a concern, and all potential sources of contamination must be identified and eliminated before analysis [2,16,17,19]. Analytical systems and sample preparation methods that are precise and efficient, can detect trace amounts of PFASs, and avoid background contamination that can lead to false positives are therefore urgently needed to properly understand the occurrence and environmental behavior of PFASs and the associated health risks [6,17,19].
The most common detection methods for measuring PFAS concentrations combine gas chromatography (GC) or liquid chromatography (LC), including high-performance (HPLC) and ultra-high-performance (UHPLC) liquid chromatography, with mass spectrometry (MS) or tandem mass spectrometry (MS/MS) [2,16,17,21,42,43,44,45,46]. GC-MS is particularly effective for volatile PFASs, but less volatile and highly polar PFASs such as PFOA and PFOS are unsuitable for direct GC-MS analysis and often require laborious derivatization, such as silylation, amidation, or acylation [16,47,48,49,50]. In contrast, LC-MS, LC-MS/MS, and UHPLC-MS/MS are the primary selective and quantitative techniques for PFASs, offering detection limits in the low ng/L (ppt) range without derivatization [35]. In particular, LC-MS/MS has become the gold standard for targeted, multicomponent PFAS analysis in complex matrices because of its high selectivity for precursor–product ion pairs, which minimizes interference, as well as its high sensitivity (ng/L or ng/kg) and quantitative accuracy [5,6,51,52,53]. Furthermore, UHPLC-MS/MS, with its low injection volume, high throughput, and short analysis time, offers even better separation efficiency, sensitivity, selectivity, and resistance to matrix interference than LC-MS/MS, which has broadened its range of applications [17]. Despite limitations such as high instrument and analysis costs, complex operation, and long analysis times, LC-MS/MS and UHPLC-MS/MS remain the most reliable methods currently available for both routine and advanced PFAS analysis [6,17,54].
However, although these highly sensitive and selective methods combining chromatography and MS have been applied to environmental, food, and biological samples, PFASs may be present at very low levels in these matrices, and even slight interference from complex matrices can compromise the precision and accuracy of the results [21]. Simple and efficient sample preparation before instrumental analysis is therefore essential for accurate and reliable PFAS measurements [2,3,6,16,18,41]. Among the sample preparation methods developed, solid-phase extraction (SPE) and solid-phase microextraction (SPME) are widely used [6,21,55]. SPE is the most commonly used adsorbent-based extraction method in PFAS analysis and is also adopted in US EPA methods. It consumes relatively little solvent in comparison with liquid-liquid solvent extraction and can be standardized, but it requires a relatively large sample volume and many steps, making extraction time-consuming and laborious. To address this problem, online SPE based on column switching and combined with LC-MS/MS has been applied to reduce the sample volume, shorten the preparation time, and minimize background contamination [19]. However, online SPE requires a complex system design and cannot reduce the volume of the final extract loaded onto the analytical column, which results in poor column retention and peak broadening and thus impairs chromatographic separation and overall analytical performance [34]. SPME extracts analytes directly from a liquid sample using fibers coated with a selective adsorbent, and it can markedly improve analytical efficiency by integrating sampling, extraction, concentration, and injection [19,21,35]. However, although SPME uses very little organic solvent and is easy to operate, SPME fibers generally have a small adsorption capacity and low adsorption efficiency, and their online coupling with LC is difficult [6].
To overcome the shortcomings of fiber SPME, we developed a sensitive online analytical method that combines in-tube solid-phase microextraction (IT-SPME) [56,57], which uses an internally coated open tubular capillary column as the extraction device, with LC-MS/MS, and we have reported its applicability to various environmental, food, and biological samples [56,57,58,59,60]. IT-SPME automates the steps from sampling to extraction and concentration of target compounds with minimal organic solvent use. This eliminates human error and background contamination during operation, allows miniaturization of the equipment, is environmentally friendly, and greatly streamlines conventional sample preparation [56,57]. In this study, we developed a fully automated online analysis system based on IT-SPME/LC-MS/MS for the accurate and precise simultaneous determination of PFOA, PFHxS, and PFOS (Figure 1) in environmental and drinking water samples, with the aim of providing an effective analytical method for researchers working to solve the PFAS issue.
2. Materials and Methods
2.1. Reagents and Equipment
Mixed PFAS standard solutions containing PFOA, PFHxS, and PFOS (2 µg/mL each in methanol) and mixed internal standard solutions containing PFOA-13C8, PFHxS-13C6, and PFOS-13C8 (2 µg/mL each in methanol) were purchased from FUJIFILM Wako Chemicals (Osaka, Japan). Before use, each standard solution was diluted with ultrapure water for PFAS analysis (FUJIFILM Wako Chemicals) to prepare 1 ng/mL working mixed standard solutions, which were stored at 4°C. PFAS-compatible LC-MS-grade acetonitrile and methanol, distilled water, and 1 M ammonium acetate solution were obtained from Kanto Chemicals (Tokyo, Japan) and used for the mobile phase and reagents. Phthalate buffer (0.1 M; pH 3, 4, and 5) and phosphate buffer (0.1 M; pH 6, 7, and 8) were purchased from Tokyo Chemical Industry Co., Ltd. (Tokyo, Japan). Vials, tubes, and filters recommended for PFAS analysis were used throughout. Two-milliliter polypropylene (PP) autosampler vials with polyether ether ketone (PEEK)/silicone septa and PP screw-cap bottles for sample storage were purchased from GL Sciences Inc. (Tokyo, Japan). PP syringe filters with 0.2 µm polyethersulfone (PES) membranes were purchased from Kanto Chemicals.
2.2. LC–MS/MS Instrumentation and Analytical Conditions
LC–MS/MS analysis was performed using a Model 1100 series LC system (Agilent Technologies, Böblingen, Germany) coupled to an API 4000 triple quadrupole mass spectrometer (Applied Biosystems, Foster City, CA, USA). Separation was carried out on an InertSustain® AQ-C18 column (2.1 × 100 mm, 3 µm particle size; GL Sciences Inc.) for 3 min at a flow rate of 200 µL/min, using 10 mM ammonium acetate/acetonitrile (25:75, v/v) as the mobile phase. The mass spectrometer was equipped with a turbo ion spray interface and operated in negative ion mode at −4500 V and 600°C. Nitrogen for the spray and drying gases was supplied by a Kaken N2 generator (System Instruments Co., Ltd., Tokyo, Japan). The ion source gas 1 (GS1) and gas 2 (GS2) flow rates were set to 40 and 70 L/min, respectively, and the curtain gas (CUR) and collision gas (CAD) flow rates were set to 20 and 8.0 L/min, respectively. Other parameters, including the dwell time per transition, declustering potential (DP), entrance potential (EP), collision energy (CE), and collision cell exit potential (CXP), are given in Table S1. PFASs were quantified by multiple reaction monitoring (MRM) of the deprotonated precursor ions [M−H]− and the corresponding product ions; the MRM transitions are also listed in Table S1. Data were processed using Analyst software version 1.6.2 (Applied Biosystems).
2.3. IT-SPME Procedure
IT-SPME [56,57] uses an autosampler injection program to automatically perform capillary washing, adsorption and concentration of the sample, and desorption with the mobile phase. A Supel-Q PLOT capillary column (60 cm × 0.32 mm i.d.) was used as the extraction device. It was connected between the injection loop and the injection needle of the autosampler using a 2.5 cm length of PEEK tubing, a standard 1/16 inch stainless steel nut, a ferrule, and a union connector.
A 1 mL aliquot of the solution containing internal standard and sample in a 2 mL PP autosampler vial with a PEEK/silicone septum was placed in the autosampler tray. Two additional vials (A and B) contained 1.5 mL of methanol each, one vial contained 1.5 mL of distilled water, and one was an empty blank vial. The methanol and distilled water were replaced periodically. First, with the six-port valve in the “LOAD” position, the capillary was washed and conditioned at a flow rate of 200 µL/min as follows: 40 µL of methanol from vial A was drawn and ejected for two cycles; 50 µL of air was drawn to remove the mobile phase from the capillary; and 40 µL of distilled water was drawn and ejected for two cycles to replace the solution in the capillary with water. Next, extraction was performed by drawing and ejecting 40 µL of the sample 20 times at 200 µL/min, during which the PFASs were adsorbed onto the stationary phase on the inner surface of the capillary. After extraction, the tip of the injection needle was washed once by drawing and ejecting 2 µL of methanol from vial B. Finally, the six-port valve was switched to the “INJECT” position, and the PFASs retained in the capillary were desorbed by the mobile phase flow and transferred to the LC-MS/MS system. The entire IT-SPME sequence and the LC-MS/MS analysis were fully automated using the autosampler control software (Analyst 1.6.2, Applied Biosystems). An overview of the IT-SPME/LC-MS/MS system is shown in Figure S1.
2.4. Optimization of IT-SPME Conditions
The factors affecting IT-SPME, namely the capillary coating, the number of draw/eject cycles, the flow rate, and the sample pH, were optimized using a 500 pg/mL PFAS mixed standard solution. Extraction efficiency was compared among commercially available capillary columns with an inner diameter of 0.32 mm: Supel-Q PLOT (divinylbenzene polymer, 12 µm film thickness; Supelco, Bellefonte, PA, USA), Carboxen 1006 PLOT (carbon molecular sieve, 17 µm; Supelco), CP-Sil 5CB (100% polydimethylsiloxane, 5 µm; Varian Inc., Lake Forest, CA, USA), CP-Sil 19CB (14% cyanopropyl-phenyl-methylsilicone, 1.0 µm; Varian Inc.), and CP-Wax 52CB (polyethylene glycol, 1.2 µm; Varian Inc.). The number of draw/eject cycles was examined from 5 to 30 at 200 µL/min, and the flow rate was examined from 50 to 250 µL/min with 20 draw/eject cycles. The effect of sample pH was examined by adding buffer solution to a final concentration of 2.5 mM (pH 3–8). Extraction efficiency under each condition was evaluated as the enrichment factor, defined as the ratio of the sensitivity of IT-SPME to that of direct injection (Equation (1)):
where A is the peak height of each PFAS obtained by direct LC-MS/MS analysis of 10 µL of the 500 pg/mL PFAS mixed standard solution, and B is the peak height obtained by IT-SPME-LC-MS/MS analysis of 1 mL of the same solution.
Enrichment factor=B/A
2.5. Method Validation
The developed method was evaluated for linearity, limit of detection (LOD), limit of quantification (LOQ), precision, and accuracy. Linearity was evaluated using the correlation coefficient of the calibration curve (n = 24), which was based on the peak height ratio of each PFAS to its internal standard. Eight concentrations of the PFAS mixed standard solutions (1, 2, 5, 10, 20, 50, 100, and 250 pg/mL) were each analyzed three times in the presence of 50 pg/mL mixed internal standard. The LOD and LOQ were calculated as the concentrations giving signal-to-noise ratios (S/N) of 3 and 10, respectively. Precision and accuracy were evaluated using low (5 pg/mL), medium (50 pg/mL), and high (250 pg/mL) PFAS mixed standard solutions, with six replicates each (n = 6). Intraday precision was assessed from six independent measurements on the same day, and interday precision from measurements on six different days. Precision was expressed as the relative standard deviation (RSD, %), and accuracy as the percentage deviation of the concentration calculated from the calibration curve from the nominal concentration. For the spike recovery test, 5, 50 and 250 pg/mL of PFASs were added to tap water and river water, and the recovery (%) was calculated.
2.6. Matrix Effects
The matrix effect was calculated from the ratio of the slopes of the calibration curves ranged from 5 to 250 pg/mL prepared in environmental or drinking water spiked with the mixed standard solutions and in the mixed standard solutions alone (Equation (2)). Values within 80–120% were considered to indicate a negligible matrix effect, whereas values below 80% or above 120% indicated signal suppression or enhancement, respectively.
where A is the slope of the calibration curve for each PFAS obtained from the mixed standard solutions, and B is the slope of the calibration curve obtained the mixed standard solutions added to the environmental or drinking water.
Matrix effect (%) = (B/A) × 100
2.7. Sampling and Sample Preparation
Water samples were collected in Okayama Prefecture in August 2026, Japan. They comprised river water (downstream, midstream, and upstream sites of the Asahi River), lake water (Kojima Lake), seawater (Okayama Port), pond water, rainwater, and tap water (from a family home and a large building), as well as soft drinks including mineral water, tea, and sports drinks in polyethylene terephthalate (PET) bottles purchased from local markets. River water, lake water, and seawater were collected from the surface in PP screw-cap bottles and were either analyzed immediately or stored at −20 °C until analysis. Samples were used directly or, if insoluble material was present, filtered through a 0.2 µm syringe filter. A 0.5 mL aliquot of each sample (0.2 mL for tea and sports drink) was placed in a 2 mL PP autosampler vial with a PEEK/silicone septum, and 50 µL of 1 ng/mL mixed internal standard solution and 25 µL of 0.1 M phosphate buffer (pH 7.0) were added. The volume was adjusted to 1 mL with ultrapure water, and the sample was analyzed by IT-SPME/LC-MS/MS. PFAS concentrations (pg/mL) were calculated from the calibration curve.
3. Results and Discussion
3.1. Optimization of IT-SPME Conditions for PFAS
IT-SPME is a simple and efficient automated sample preparation technique that extracts and concentrates target analytes from a sample solution into a capillary column without organic solvents, allowing continuous analysis of multiple samples [56,57]. Immediately before each analysis, the capillary was conditioned by washing with methanol and ultrapure water to remove contaminants. The air gap in the conditioning program was necessary to prevent mixing of the mobile phase with the sample solution and to avoid desorption of the analytes extracted onto the capillary coating during the extraction step. Using a 500 pg/mL PFAS mixed standard solution, we optimized the capillary coating, the number of draw/eject cycles, the flow rate, and the sample pH. Extraction efficiency was evaluated as the enrichment factor of IT-SPME relative to direct injection.
Five commercially available GC capillary columns with different stationary phases were compared. All PFASs were extracted more efficiently onto the porous polymer phase with a large surface area (Figure 2A). The Supel-Q PLOT capillary gave the highest extraction efficiency and good peak shapes and was therefore used as the extraction device. In IT-SPME, analytes are extracted onto the capillary coating by repeatedly drawing and ejecting the sample solution. When 5, 10, 15, 20, 25, and 30 cycles were tested with the Supel-Q PLOT capillary, the extraction efficiency increased with the number of cycles, but the rate of increase slowed after 20 cycles (Figure 2B). Considering the analysis time, 20 cycles were selected. When flow rates of 50, 100, 150, 200, and 250 µL/min were tested with 20 cycles, the extraction efficiency was almost unchanged between 50 and 200 µL/min (Figure S2A). Because higher flow rates shorten the analysis time, 200 µL/min was selected.
The pH of the sample solution was varied from 3 to 8 (Figure S2B). The extraction efficiencies of PFHxS and PFOS were almost unchanged between pH 3 and 8, whereas that of PFOA was higher with phosphate buffer at pH 6–8. These results suggest that all three PFASs have pKa values below 1 [19] and are almost fully ionized at pH ≥ 3, so their extraction was not pH-dependent and was instead influenced by their relatively high n-octanol–water partition coefficients (log Kow: 4.81 for PFOA, 4.49 for PFOS, 3.16 for PFHxS) based on the perfluoroalkyl chains [19]. Therefore, the samples were adjusted to pH 7, at which stable values were obtained, with a buffer concentration of 2.5 mM, because stable high values were obtained at 2–5 mM.
The PFASs extracted into the capillary were eluted by the mobile phase flow and introduced directly online into the LC-MS/MS system. No peaks were observed when blank water was analyzed immediately after a standard solution, indicating that the PFASs were almost completely desorbed from the capillary. In addition, the extraction efficiency did not decrease after at least 500 analyses of standard solutions and water samples, indicating that the capillary is stable and reusable.
3.2. LC–MS/MS Analysis of PFAS
PFASs and their stable isotope-labeled internal standards showed good sensitivity in negative electrospray ionization (ESI–) mode. The deprotonated molecular ion [M–H]– and the most intense product ion generated from it were selected as the precursor ion (Q1) and product ion (Q3), respectively. The optimized MS/MS parameters and MRM transitions (Table S1) were consistent with previously reported values [61,62]. The chromatographic conditions were optimized to minimize matrix effects, maintain good peak shapes, and shorten the analysis time. Among the LC columns tested, the InertSustain AQ-C18 column (2.1 × 100 mm, 3 µm) gave the best resolution and peak shapes. As shown in Figure 3, the three PFASs and their internal standards each eluted as a single peak within 3 min with 10 mM ammonium acetate/acetonitrile (25:75, v/v) at 0.2 mL/min. A small secondary peak from branched isomers appeared before the main peak of the linear isomer of each PFAS; only the linear-isomer peak was analyzed in this study.
For the blank test, sample solutions were prepared from ultrapure water filtered through a syringe filter, with no added PFAS standards or internal standards, and were analyzed by IT-SPME/LC-MS/MS immediately after the analysis of a 250 pg/mL PFAS standard. As shown in Figure S3, no peaks overlapping with the PFASs or internal standards were detected above the noise level in any chromatogram. This indicates no background contamination from the mobile phase solvents, syringe filter, autosampler vial, or instrument, and no carryover from the preceding sample. The total analysis time, from capillary conditioning through IT-SPME extraction and concentration, online injection, chromatographic separation, and MS/MS detection, was approximately 20 min per sample. This allows unattended analysis of approximately 72 samples per day, which saves considerable labor.
3.3. Method Validation
The validation results for the three PFASs, including linearity, LOD, precision, and accuracy, are shown in Table 1 and Table 2. Calibration curves in the range of 1–250 pg/mL (eight concentrations, each measured three times) were linear, with correlation coefficients of R² ≥ 0.9998 (n = 24). The LODs (S/N = 3) ranged from 0.058 to 0.229 pg/mL, with a slightly higher value for PFOS, and the sensitivity was 23–49 times higher than that of direct injection. When reproducibility was evaluated at low, medium, and high concentrations, the intraday and interday precision were ≤ 7.2% and ≤ 8.3%, respectively, and the accuracy was 95–109%. These values are acceptable for the quantitative analysis of PFASs. The developed IT-SPME/LC-MS/MS method therefore simplifies and automates the analysis by integrating online extraction and concentration, while providing selective and sensitive determination.
3.4. Application to the Analysis of Environmental and Drinking Water Samples.
Samples were analyzed immediately after collection, filtered through a syringe filter if insoluble matter was present, or frozen at −20°C and analyzed within one week if analysis on the day of collection was not possible. No degradation or loss of PFASs was observed during storage. Environmental and drinking water samples contain various matrix components that can cause ion suppression or enhancement in LC-MS/MS analysis. Figure 4 shows an MRM chromatogram of river water. A side peak was observed before the PFHxS peak, but almost no interfering peaks were observed for PFOA and PFOS.
To evaluate matrix effects, PFAS mixed standard solutions were spiked into tap water and river water at 5, 50, and 250 pg/mL. Matrix effects were calculated from the slopes of the calibration curves of the standard solutions and of the spiked water samples, both based on peak height. As shown in Table 3, the matrix effects ranged from 96.4% to 101.3%, indicating minimal matrix influence. The LOQs (S/N = 10) in environmental and drinking water samples were 0.23–0.84 pg/mL (Table 1), and the recoveries of PFASs spiked into tap water and river water were above 93% (Table 3). These results indicate that the method is suitable for the quantitative analysis of trace PFASs in water samples.
Table 4 shows the results for 14 environmental water samples (lake water, seawater, river water, and rainwater) and 14 drinking water samples (tap water, mineral water and soft drinks purchased from local markets) collected in Okayama Prefecture. In environmental water, the concentrations of PFOA, PFHxS, and PFOS were 5.08–49.39, 0.80–6.70, and 1.20–28.00 pg/mL, respectively; in drinking water, they were 5.62–76.16, 0.25–4.16, and 1.36–69.77 pg/mL, respectively. PFHxS concentrations were lower than those of PFOA and PFOS, whereas PFOA and PFOS varied among samples. Trace amounts of PFASs were detected in rainwater. PFAS concentrations in other environmental waters were not particularly high in downstream rivers or seawater, and were varied depending on local contamination levels, so no specific trend was observed.
In tap water, PFOA and PFOS concentrations were relatively high (several tens of pg/mL) in samples from buildings with storage tanks (Table 4, No. 18 and 19) compared with those from single-family homes (No. 15–17). However, none exceeded the 50 pg/mL limit in Japan’s tap water quality standards. Commercially available mineral water contained PFASs at levels similar to those in tap water. In addition, relatively high concentrations of PFAS were detected in soft drinks in PET bottles; in particular, tea contained higher levels of PFOA than PFOS. This contamination may originate from the environmental factors at the manufacturing sites and the water used in the manufacturing process. Furthermore, tap water (No. 17) and river water (No. 9 and 10) from an area where environmental contamination was discovered three years ago, caused by the illegal dumping of PFAS-laden activated carbon, showed levels almost equal to those in other areas. This suggests that the removal of the waste and the subsequent decontamination were effective. These findings indicate that, despite current regulations on the manufacture and use of PFOA, PFHxS, and PFOS, these compounds were still detected in environmental and drinking water. This suggests that PFAS contamination accumulated over many years is difficult to eliminate completely, even through water purification treatment of river water and other sources used to produce drinking water. PFASs and their stable isotope-labeled internal standards showed good sensitivity in negative electrospray ionization (ESI–) mode. The deprotonated molecular ion [M–H]– and the most intense product ion generated from it were selected as the precursor ion (Q1) and product ion (Q3), respectively. The optimized MS/MS parameters and MRM transitions (Table S1) were consistent with previously reported values [61,62]. The chromatographic conditions were optimized to minimize matrix effects, maintain good peak shapes, and shorten the analysis time. Among the LC columns tested, the InertSustain AQ-C18 column (2.1 × 100 mm, 3 µm) gave the best resolution and peak shapes. As shown in Figure 3, the three PFASs and their internal standards each eluted as a single peak within 3 min with 10 mM ammonium acetate/acetonitrile (25:75, v/v) at 0.2 mL/min. A small secondary peak from branched isomers appeared before the main peak of the linear isomer of each PFAS; only the linear-isomer peak was analyzed in this study.
3.5. Comparison with Conventional Methods
Analytical methods for determining PFAS contamination in aquatic environments have been summarized in numerous reviews [6,18,19,21,35,41]. Table 5 summarizes the characteristics of the main LC–MS/MS methods for PFASs reported over the past five years. Direct injection method [61] requires only 5–10 min for sample preparation, but has low sensitivity. Many methods use SPE for sample preparation require multiple steps (conditioning, adsorption, washing, elution, and concentration) with solvents such as acetonitrile, methanol, and ammonia. In addition, these methods require tens to hundreds of milliliters of sample and 57–132 min of processing [61], depending on the procedure and matrix. Some of these methods offer high sensitivity, but most do not, and some show poor accuracy and recoveries. Automated online SPE/LC-MS/MS methods have been reported [66]; they require a relatively small sample volume of 2 mL and shorten the preparation time to 30 min, but their sensitivity is not particularly high. Microextraction techniques such as pipette-tip SPE (PT-SPE), dispersive SPE (d-SPE), magnetic SPE (MSPE), and fiber SPME reduce the sample volume and organic solvent consumption because of the miniaturized extraction devices and improved selectivity, but they are not automated.
The IT-SPME LC–MS/MS method developed in this study requires only 0.5 mL of sample, and the sample preparation process can be performed fully automatically in approximately 15 min. It also can be connected online to an LC-MS/MS system, and shows sensitivity, accuracy, and precision comparable to or better than those of the conventional methods in Table 5. Furthermore, it needs no organic solvents other than methanol, used for cleaning the vials and tubes, and acetonitrile, used in the mobile phase. However, whereas conventional methods target a wide range of PFASs, this study provides data for only three representative PFASs. The method should therefore be extended to a larger number of target PFASs in the future.
4. Conclusion
In this study, we developed an automated method for the determination of PFOA, PFHxS, and PFOS in water samples, in which the analytes are extracted and concentrated by IT-SPME with a Supel-Q PLOT capillary and the extract is introduced online into LC-MS/MS. As summarized in Table 5, most previously reported methods rely on SPE, which involves relatively complex and time-consuming extraction and concentration steps. In contrast, the present method can be applied to small sample volumes and requires no organic solvent for extraction or concentration, which reduces solvent consumption and exposure to hazardous chemicals. Its main novelty is the fully automated, online integration of sample pretreatment and chromatographic analysis. Because extraction, concentration, and injection are performed in a closed flow path with little manual handling, the risk of contamination during sample preparation is low, and no background contamination or carryover was detected in the blank tests. The concentration effect of IT-SPME provided high sensitivity, enabling accurate quantification of PFASs in various environmental and drinking water samples with minimal matrix effects. Although only three major PFASs were studied here, the method may be applicable to a wider range of structurally different PFASs, which should be examined in future work. The method aimed for environmentally friendly and safe "green" analysis is therefore expected to be useful for monitoring PFAS contamination in environmental water and for evaluating tap water and drinking water quality.
Supplementary Materials
The following supporting information can be downloaded at the website of this paper posted on Preprints.org, Figure S1: On-line IT-SPME LC−MS/MS system; Figure S2: Effects of (A) the draw/eject flow rate and (B) the sample pH on the IT-SPME of PFOA, PFHxS, and PFOS (500 pg/mL each). Extraction was performed with a Supel-Q PLOT capillary using 20 draw/eject cycle of 40 μL of standard solution. Error bars show the standard deviation; Figure S3: MRM chromatograms of blank water analyzed immediately after a 250 pg/mL PFAS standard. Analytical conditions are described in the Section 2; Table S1: MS/MS conditions for PFOA, PFHxS, and PFOS and their stable isotope-labeled internal standards.
Author Contributions
H.K.: Conceptualization, Methodology, Software, Validation, Formal analysis, Investigation, Resources, Data curation, Writing—original draft preparation, Writing—review and editing, Visualization, Supervision, Project administration, K.I.: Formal analysis, Investigation, All authors have read and agreed to the published version of the manuscript. All authors have read and agreed to the published version of the manuscript.
Funding
This research did not receive any specific grant from funding agencies in the public, commercial, or not for-profit sectors.
Data Availability Statement
Data presented in this study are available, upon reasonable request, from the corresponding author.
Conflicts of Interest
The authors declare no conflicts of interest.
Abbreviations
The following abbreviations are used in this manuscript:
| PFASs | per- and polyfluoroalkyl substances |
| IT-SPME | in-tube solid-phase microextraction |
| LC-MS/MS | liquid chromatography-tandem mass spectrometry |
| POPs | persistent organic pollutants |
| PFOS | perfluorooctanesulfonic acid |
| PFOA | perfluorooctanoic acid |
| PFHxS | perfluorohexanesulfonic acid |
| GC | gas chromatography |
| LC | liquid chromatography |
| HPLC | high-performance liquid chromatography |
| UPLC | ultra-high-performance liquid chromatography |
| MS | mass spectrometry |
| MS/MS | tandem mass spectrometry |
| SPE | solid-phase extraction |
| SPME | solid-phase microextraction |
| PP | polypropylene |
| PEEK | polyether ether ketone |
| PES | polyether sulfone |
| PET | polyethylene terephthalate |
| CUR | curtain gas |
| CAD | impacting gas |
| DP | declustering potential |
| EP | inlet potential |
| CE | collision energy |
| CXP | collision cell exit potential |
| MRM | multiple reaction monitoring |
| LOD | limit of detection |
| LOQ | limit of quantification |
| S/N | signal-to-noise ratios |
| SD | standard deviation |
| RSD | elative standard deviation |
| PT-SPE | pipette tip solid-phase extraction |
| d-SPE | dispersion solid-phase extraction |
| MSPE | magnetic solid-phase extraction |
References
- Galluzzo, F.G.; Cammilleri, G.; Pantano, L.; Calabrese, V.; Buscemi, M.D.; Messina, E.M.D.; Alfano, C.; Bonomo, D.; Pulvirenti, A.; Macaluso, A.; Ferrantelli, V.; Lo Dico, G.M. QuEChERS-based LC-MS/MS and HRMS methods for PFAS determination in food: A systematic review. Foods 2026, 15, 1872. [Google Scholar] [CrossRef] [PubMed]
- Mišľanová, C.; Valachovičová, M. Health impacts of per- and polyfluoroalkyl substances (PFASs): A comprehensive review. Life 2025, 15, 573. [Google Scholar] [CrossRef] [PubMed]
- Dhiman, S.; Ansari, N.G. A review on extraction, analytical and rapid detection techniques of per/poly fluoro alkyl substances in different matrices. Microchem. J. 2024, 196, 109667. [Google Scholar] [CrossRef]
- Arana Juve, J.-M.; Wang, B.; Wong, M.S.; Ateia, M.; Wei, Z. Complete defluorination of per- and polyfluoroalkyl substances—Dream or reality? Curr. Opin. Chem. Eng. 2023, 41. [Google Scholar] [PubMed]
- Hauschildt, C.; Becker, R. Per- and polyfluoroalkyl substances (PFAS) in food contact materials: A critical review of analytical strategies, migration behavior, and regulatory frameworks (2005 - 2025). Anal. Chim. Acta. 2026, 1421, 345997. [Google Scholar] [CrossRef] [PubMed]
- Herok, M.; Barchanska, H.; Partyka, M. From sampling to screening: A review of targeted and non-targeted PFAS analysis in environmental samples. Crit. Rev. Anal. Chem. 2026, 11, 1–23. [Google Scholar] [CrossRef] [PubMed]
- Dobrzyńska, Elżbieta; Wasilewski, Paweł; Pośniak, Małgorzata. Per- and Polyfluoroalkyl Substances (PFASs): A Comprehensive Review of Environmental Distribution, Health Impacts, and Regulatory Landscape. Appl. Sci. 2025, 15, 11884. [Google Scholar] [CrossRef]
- Podder, A.; Sadmani, A.H.M.A.; Reinhart, D.; Chang, N.B.; Goel, R. Per and poly-fluoroalkyl substances (PFAS) as a contaminant of emerging concern in surface water: A transboundary review of their occurrences and toxicity effects. J. Hazard. Mater. 2021, 419, 126361. [Google Scholar] [CrossRef] [PubMed]
- Leung, S.C.E.; Wanninayake, D.; Chen, D.; Nguyen, N.-T.; Li, Q. Physicochemical properties and interactions of perfluoroalkyl substances (PFAS)—Challenges and opportunities in sensing and remediation. Sci. Total Environ. 2023, 5, 166764. [Google Scholar] [CrossRef] [PubMed]
- John, J.; Coulon, F.; Chellam, P.V. Detection and treatment strategies of per- and polyfluoroalkyl substances (PFAS): Fate of PFAS through DPSIR framework analysis. J. Water Process Eng. 2022, 45, 102463. [Google Scholar] [CrossRef]
- Wee, S.Y.; Aris, A.Z. Revisiting the “Forever chemicals”, PFOA and PFOS exposure in drinking water. npj Clean Water 2023, 6, 57. [Google Scholar] [CrossRef]
- Klingelhöfer, D.; Braun, M.; Groneberg, D.A.; Brüggmann, D. The “Forever” per- and polyfluoroalkyl substances (PFAS): A critical accounting of global research on a major threat under changing regulations. Chemosphere 2024, 354, 141694. [Google Scholar] [CrossRef] [PubMed]
- Mallek, M.; Barcelo, D. Analysis and fate of per- and polyfluoroalkyl substances (PFAS) in the global aquatic environment: perspectives and combined risks with microplastics. Anal. Bioanal. Chem. 2026, 418, 3509–3535. [Google Scholar] [CrossRef] [PubMed]
- Varga, I.; Bilandžić, N.; Kaurinović, J.; Bošković, A.G.; Klapec, T. Per- and polyfluoroalkyl substances in fish: global occurrence, bioaccumulation, analytical approaches, and human exposure risks-A review. Toxics 2026, 14, 336. [Google Scholar] [CrossRef] [PubMed]
- Bonato, T.; Pal, T.; Benna, C.; Di Maria, F. Contamination of the terrestrial food chain by per- and polyfluoroalkyl substances (PFAS) and related human health risks: A systematic review. Sci. Total Environ. 2025, 961, 178337. [Google Scholar] [CrossRef] [PubMed]
- Cui, Y.; Wang, S.; Han, D.; Yan, H. Advancements in detection techniques for per- and polyfluoroalkyl substances: A comprehensive review. TrAC Trends Anal. Chem. 2024, 176, 117754. [Google Scholar] [CrossRef]
- Li, S.; Wang, Q.; Lyu, L.; Leng, J. Pretreatment and detection of per- and polyfluoroalkyl substances (PFAS): A review of current advancements, development challenges, and perspectives. Microchem. J. 2025, 213, 113789. [Google Scholar] [CrossRef]
- Liu, Z.; Wang, G.; Zheng, X.; Sepúlveda, M.S.; Wang, B.; Zhang, H. Detection methods, distribution and ecological risks of per- and polyfluoroalkyl substances (PFAS) in aquatic environments: Research advances and future perspectives. TrAC Trends Anal. Chem. 2026, 200, 118826. [Google Scholar] [CrossRef]
- Zarębska, M.; Bajkacz, S. Poly– and perfluoroalkyl substances (PFAS) - recent advances in the aquatic environment analysis. Trends Anal. Chem. 2023, 163, 1 117062. [Google Scholar] [CrossRef]
- Chung, Y.-P.; Lin, J.-T.; Lee, Y.-Y.; Nguyen, P.T.; Huynh, T.T.T.; Lu, M.-J.; Huang, B.-W.; Sriram, B.; Wang, S.-F.; Kogularasu, S.; Chang-Chien, G.-P. Comparative review of conventional and emerging PFAS detection methods: A focus on detection strategies. Microchem. J. 2025, 217, 115103. [Google Scholar] [CrossRef]
- Liu, P.; Li, J.; Hong, L.; Zou, H.; Zhou, X.; Zhang, X.; Zhou, Y.; Lee, H.K.; Huang, Z. Analysis of per-and polyfluorinated alkyl substances by chromatography-mass spectrometry: A review. J. Chromatogr. A 2025, 1760, 466261. [Google Scholar] [CrossRef] [PubMed]
- Glüge, J.; Scheringer, M.; Cousins, I.T.; Dewitt, J.C.; Goldenman, G.; Herzke, D.; Lohmann, R.; Ng, C.A.; Trier, X.; Wang, Z. An overview of the uses of per- and polyfluoroalkyl substances (PFAS). Environ. Sci. Process. Impacts 2020, 22, 2345–2373. [Google Scholar] [CrossRef] [PubMed]
- Mulka, R.; Su, D.; Huang, W.-S.; Zhang, L.; Huang, H.; Lai, X.; Li, Y.; Xue, X.-S. FluoBase: A fluorinated agents database. J. Cheminform. 2025, 17, 19. [Google Scholar] [CrossRef] [PubMed]
- Glüge, J.; Scheringer, M.; Cousins, I.T.; DeWitt, J.C.; Goldenman, G.; Herzke, D.; Wang, Z. An overview of the uses of per- and polyfluoroalkyl substances (PFAS). Environ. Sci. Process. Impacts 2020, 22, 2345–2373. [Google Scholar] [CrossRef] [PubMed]
- Gaines, L.G.T. Historical and current usage of per- and polyfluoroalkyl substances (PFAS): A literature review. Am. J. Ind. Med. 2023, 66, 353–378. [Google Scholar] [CrossRef] [PubMed]
- Panieri, E.; Baralic, K.; Djukic-Cosic, D.; Buha Djordjevic, A.; Saso, L. PFAS molecules: A major concern for the human health and the environment. Toxics 2022, 10, 44. [Google Scholar] [CrossRef] [PubMed]
- Barisci, S.; Suri, R. Occurrence and removal of poly/perfluoroalkyl substances (PFAS) in municipal and industrial wastewater treatment plants. Water Sci. Technol. 2021, 84, 3442–3468. [Google Scholar] [CrossRef] [PubMed]
- Teymoorian, T.; Munoz, G.; Vo Duy, S.; Liu, J.; Sauvé, S. Tracking PFAS in drinking water: A review of analytical methods and worldwide occurrence trends in tap water and bottled water. ACS EST Water 2023, 3, 246–261. [Google Scholar] [CrossRef]
- Podder, A.; Sadmani, A.A.; Reinhart, D.; Chang, N.B.; Goel, R. Per- and polyfluoroalkyl substances (PFAS) as a contaminant of emerging concern in surface water: A transboundary review of their occurrences and toxicity effects. J. Hazard. Mater. 2021, 419, 126361. [Google Scholar] [CrossRef] [PubMed]
- Kumar, E.; Koponen, J.; Rantakokko, P.; Airaksinen, R.; Ruokojarvi, P.; Kiviranta, H.; Vuorinen, P.J.; Myllyla, T.; Keina, M.; Raitaniemi, J.; Mannio, J.; Junttila, V.; Nieminen, J.; Vena, E.-R.; Jestoi, M. Distribution of perfluoroalkyl acids in fish species from the Baltic Sea and freshwaters in Finland. Chemosphere 2022, 291, 132688. [Google Scholar] [CrossRef] [PubMed]
- Liu, Y.; Zhang, Q.; Li, Y.; Hao, Y.; Li, J.; Zhang, L.; Wang, P.; Yin, Y.; Zhang, S.; Li, T.; Wang, Y.; Dong, S.; Wei, S.; Zhang, W.; Su, X.; Li, X. Occurrence of per- and polyfluoroalkyl substances (PFASs) in raw milk and feed from nine Chinese provinces and human exposure risk assessment. Chemosphere 2022, 300, 134521. [Google Scholar] [CrossRef] [PubMed]
- Liu, Y.; Zhang, W.; Zhu, G.; Pei, T.; Guo, G.; Wang, X.; Zhao, Y. Methods for sample pretreatment and detection of per- and polyfluoroalkyl substances in biological samples: A review. TrAC Trends Anal. Chem. 2025, 187, 118206. [Google Scholar] [CrossRef]
- Zhao, Z.; Yue, L.; Qiao, H.; Li, Y.; Cheng, X.; Hua, X.; Lin, T.; Li, Q.; Sun, H. Perfluoroalkyl acids in dust on residential indoor/ outdoor window glass in Chinese cities: occurrence, composition, and toddler exposure. Environ. Sci. Pollut. Res. 2022, 29, 13881–13892. [Google Scholar] [CrossRef]
- Kee, K.H.; Seo, J.I.; Kim, S.M.; Shiea, J.; Yoo, H.H. Per- and polyfluoroalkyl substances (PFAS): Trends in mass spectrometric analysis for human biomonitoring and exposure patterns from recent global cohort studies. Environ. Int. 2024, 194, 109117. [Google Scholar] [CrossRef] [PubMed]
- Manousi, N.; Anthemidis, A. Practicality evaluation of novel microextraction techniques for the determination of PFAS in food and water samples using the Blue Applicability Grade Index. Anal. Chim. Acta 2025, 1352, 343864. [Google Scholar] [CrossRef] [PubMed]
- Cara, B.; Lies, T.; Thimo, G.; Robin, L.; Lieven, B. Bioaccumulation and trophic transfer of perfluorinated alkyl substances (PFAS) in marine biota from the Belgian north sea: Distribution and human health risk implications. Environ. Pollut. 2022, 311, 119907. [Google Scholar] [CrossRef] [PubMed]
- Gautam, R.K.; Mottaghipisheh, J.; Verma, S.; Singh, R.P.; Muthukumaran, S.; Navaratna, D.; Ahrens, L. PFAS contamination in key Indian States: A critical review of environmental impacts, regulatory challenges and predictive exposure. J. Hazard. Mater. Adv. 2025, 18, 100748. [Google Scholar] [CrossRef]
- Mahoney, H.; Xie, Y.; Brinkmann, M.; Giesy, J.P. Next generation per- and poly- fluoroalkyl substances: Status and trends, aquatic toxicity, and risk assessment. Eco-Environ. Health 2022, 1, 117–131. [Google Scholar] [CrossRef] [PubMed]
- Fenton, S.; Ducatman, A.; Boobis, A.; DeWitt, J.; Lau, C.; Ng, C.; Smith, J.; Roberts, S. Per- and polyfluoroalkyl substance toxicity and human health review: current state of knowledge and strategies for informing future research. Environ. Toxicol. Chem. 2021, 40, 606–30. [Google Scholar] [CrossRef] [PubMed]
- Wang, Q.; Ruan, Y.; Yuen, C.M.T.; Lin, H.; Yeung, L.W.Y.; Leung, K.M.Y.; Lam, P.K.S. Tracing per- and polyfluoroalkyl substances (PFASs) in the aquatic environment: Target analysis and beyond. TrAC Trends Anal. Chem. 2023, 169, 117351. [Google Scholar] [CrossRef]
- Gao, M.K.; Chen, Y.; Xue, Q.; Fu, J.; Fu, K.; Fu, J.; Zhang, A.; Cai, Z.; Jiang, G. Trends and perspectives in per-and polyfluorinated alkyl substances (PFASs) determination: Faster and broader. TrAC Trends Anal. Chem. 2020, 133, 116114. [Google Scholar] [CrossRef]
- Nam, D.H.; Kim, H.; Ban, H.; Durak, Ö.; Park, J.; Fortner, J.D.; Lee, S. Beyond persistence: SERS-driven strategies for PFAS detection and monitoring. Nano Converg. 2026, 11. [Google Scholar] [CrossRef] [PubMed]
- Cui, Y.; Wang, S.; Han, D.; Yan, H. Advancements in detection techniques for per- and polyfluoroalkyl substances: A comprehensive review. TrAC Trends Anal. Chem. 2024, 176, 117754. [Google Scholar] [CrossRef]
- Belay, M.H.; Robotti, E.; Ghignone, A.; Fabbris, A.; Brandi, J.; Cecconi, D.; Masini, M.A.; Dondero, F.; Marengo, E. Sensitive and accurate determination of 32 PFAS in human serum using online SPE-UHPLC-HRMS. J. Hazard. Mater. 2025, 485, 136780. [Google Scholar] [CrossRef] [PubMed]
- Genualdi, S.; deJager, L. Determination of 30 PFAS in food and feed using LC-MS/MS; FDA method C-010.03, Version 3.0; U.S. Food and Drug Administration, 2024; Available online: https://www.fda.gov/media/131510/download.
- U.S. Environmental Protection Agency Method 1633, Analysis of per- and polyfluoroalkyl substances (PFAS) in aqueous,solid, biosolids, and tissue samples by LC-MS/MS. U.S. EPA: Washington, DC, 2024. Available online: https://www.epa.gov/cwa-methods/cwa-analytical-methods-and-polyfluorinated-alkyl-substances-pfas#method-1633. (accessed on 2026).
- Ji, Y.; Cui, Z.; Li, X.; Wang, Z.; Zhang, J.; Li, A. Simultaneous determination of nine perfluoroalkyl carboxylic acids by a series of amide acetals derivatization and gas chromatography tandem mass spectrometry. J. Chromatogr. A 2020, 1622, 461132. [Google Scholar] [CrossRef] [PubMed]
- Stróżyńska, M.; Schuhen, K. Dispersive solid-phase extraction followed by triethylsilyl derivatization and gas chromatography mass spectrometry for perfluorocarboxylic acids determination in water samples. J. Chromatogr. A 2019, 1597, 1–8. [Google Scholar] [CrossRef] [PubMed]
- Ayala-Cabrera, J.F.; Contreras-Llin, A.; Moyano, E.; Santos, F.J. A novel methodology for the determination of neutral perfluoroalkyl and polyfluoroalkyl substances in water by gas chromatography-atmospheric pressure photoionisation-high resolution mass spectrometry. Anal. Chim. Acta 2020, 1100, 97–106. [Google Scholar] [CrossRef] [PubMed]
- Ma, S.-Y.; Wang, J.; Fan, L.; Duan, H.-L.; Zhang, Z.-Q. Preparation of a fluorinated metal-organic framework and its application for the dispersive solid-phase extraction of perfluorooctanoic acid. J. Chromatogr. A 2020, 1611, 460616. [Google Scholar] [CrossRef] [PubMed]
- Jia, S.; M. Dos Santos, M.M.; Li, C.; Snyder, S.A. Recent advances in mass spectrometry analytical techniques for per- and polyfluoroalkyl substances (PFAS). Anal. Bioanal. Chem. 2022, 414, 2795–2807. [Google Scholar] [CrossRef] [PubMed]
- Encarnacion, E.K.P.; Alcantara, A.C.; Armario, H.E.; Alejandro, W.P.; Zhan, Z.; Sun, Z.; Lin, N. Preliminary screening of Per- and polyfluoroalkyl substances (PFAS) in Philippine fast food packaging using liquid chromatography–mass spectrometry (LC-MS). Curr. Res. Nutr. Food Sci. J. 2024, 12, 423–436. [Google Scholar] [CrossRef]
- Suman, T.Y.; Kwak, I.S. Current understanding of human bioaccumulation patterns and health effects of exposure to perfluorooctane sulfonate (PFOS). J. Hazard. Mater. 2025, 487, 137249. [Google Scholar] [CrossRef]
- Ismail, U.M.; Elnakar, H.; Khan, M.F. Sources, fate, and detection of dust-associated perfluoroalkyl and polyfluoroalkyl substances (PFAS). A review. Toxics 2023, 11, 335. [Google Scholar] [CrossRef] [PubMed]
- Idowu, I. G.; Ekpe, O. D.; Megson, D.; Bruce-Vanderpuije, P.; Sandau, C. D. A systematic review of methods for the analysis of total per- and polyfluoroalkyl substances (PFAS). Sci. Total Environ. 2025, 967, 178644. [Google Scholar] [CrossRef]
- Kataoka, H. In-tube solid-phase microextraction: Current trends and future perspectives. J. Chromatogr. A 2021, 1636, 461787. [Google Scholar] [CrossRef] [PubMed]
- Kataoka, H.; Ishizaki, A.; Saito, K. Solid-phase microextraction for pharmaceutical and biomedical analysis. Anal. Methods 2016, 8, 5773–5788. [Google Scholar] [CrossRef]
- Saito, K.; Ikeuchi, R.; Kataoka, H. Determination of ochratoxins in nuts and grain samples by in-tube solid-phase microextraction coupled with liquid chromatography-mass spectrometry. J. Chromatogr. A 2012, 1220, 1–6. [Google Scholar] [CrossRef] [PubMed]
- Ishizaki, A.; Kataoka, H. A sensitive method for the determination of tobacco-specific nitrosamines in main- and side-stream smoke samples by online in-tube solid-phase microextraction coupled with liquid chromatography-tandem mass spectrometry. Anal. Chim. Acta 2019, 1075, 98–105. [Google Scholar] [CrossRef] [PubMed]
- Kataoka, H.; Mizuno, K.; Oda, E.; Saito, A. Determination of the oxidative stress biomarker urinary 8-hydroxy-2'-deoxyguanosine by automated on-line in-tube solid-phase microextraction coupled with liquid chromatography-tandem mass spectrometry. J. Chromatogr. B 2016, 1019, 140–146. [Google Scholar] [CrossRef] [PubMed]
- Herok, M.; Barchańska, H.; Partyka, M.; Chrubasik, M. Beyond target lists: direct injection liquid chromatography-tandem mass spectrometry for comprehensive monitoring of legacy and emerging per- and polyfluoroalkyl substances in water systems. J. Chromatogr. A. 2026, 1787, 467392. [Google Scholar] [CrossRef] [PubMed]
- Kobayashi, N.; Takagi, S.; Kinoshita, T.; Sakata, O.; Nakano, F.; Watanabe, N.; Nomura, A.; Kawai, N.; Hiraiwa, T.; Okumura, M.; Furukawa, K.; Kasuya, T.; Iwama, N.; Yonekubo, J.; Takahara, R.; Tanaka, S.; Tsuchiya, Y.; Ikarashi, Y. Development and Validation of an Analytical Method for Simultaneous Determination of Perfluoroalkyl Acids in Drinking Water by Liquid Chromatography/Tandem Mass Spectrometry. J. Water Environ. Technol. 2022, 20, 219–237. [Google Scholar] [CrossRef]
- Awchi, M.; Gebbink, W.A.; Berendsen, B.J.A.; Benskin, J.P.; van Leeuwen, S.P.J. Development, validation, and application of a new method for the quantitative determination of monohydrogen-substituted perfluoroalkyl carboxylic acids (H-PFCAs) in surface water. Chemosphere 2022, 287 Pt 2, 132143. [Google Scholar] [CrossRef] [PubMed]
- Geiger, M.J.; Morrison, J.M.; Carmack, D.J.; Lockwood-O'Brien, S.Y.; Stagliano, M.C.; Karrer, T.A. A high-throughput small volume matrix based calibration using isotope dilution liquid chromatography tandem mass spectrometry analysis for 42 per and polyfluoroalkyl substances in groundwater. J. Chromatogr. A 2024, 1716, 464633. [Google Scholar] [CrossRef] [PubMed]
- Elabbadi, D.; Elliss, H.; Robertson, M.; Bagnall, J.; Kasprzyk-Hordern, B. A new multi-residue method for PFAS analysis in wastewater for environmental and public health risk assessment. Anal. Bioanal. Chem. 2026, 418, 2917–2938. [Google Scholar] [CrossRef] [PubMed]
- Guerra de Navarro, M.; Cuchimaque Lugo, C.; Quinete, N. Rapid quantification of per- and polyfluoroalkyl substances (PFAS) in complex wastewater matrices via online SPE-LC-MS/MS method. J. Chromatogr. A. 2026, 1783, 467183. [Google Scholar] [CrossRef] [PubMed]
- Li, X.; Fatowe, M.; Cui, D.; Quinete, N. Assessment of per- and polyfluoroalkyl substances in Biscayne Bay surface waters and tap waters from South Florida. Sci. Total Environ. 2022, 806 Pt 1, 150393. [Google Scholar] [CrossRef] [PubMed]
- Jurikova, M.; Dvorakova, D.; Pulkrabova, J. The occurrence of perfluoroalkyl substances (PFAS) in drinking water in the Czech Republic: a pilot study. Environ. Sci. Pollut. Res. Int. 2022, 29, 60341–60353. [Google Scholar] [CrossRef] [PubMed]
- Hua, L.; Donald, W.A. Assessment of per- and polyfluoroalkyl substances in Sydney drinking water. Chemosphere 2025, 385, 144611. [Google Scholar] [CrossRef] [PubMed]
- Deji, Z.; Zhang, X.; Liu, P.; Wang, X.; Abulaiti, K.; Huang, Z. Electrospun UiO-66-F4/polyacrylonitrile nanofibers for efficient extraction of perfluoroalkyl and polyfluoroalkyl substances in environmental media. J. Hazard Mater. 2022, 430, 128494. [Google Scholar] [CrossRef] [PubMed]
- Khosrowshahi, E.M.; Khataee, A.; Arefi-Oskoui, S.; Orooji, Y. Dispersive solid phase extraction of perfluorooctanoic acid from wastewater using chromium- doped CoFe layered double hydroxide for determination by LC-MS/MS. Microchem. J. 2024, 199, 109918. [Google Scholar] [CrossRef]
- Petromelidou, S.; Zoi, T.; Alampanos, V.; Bikiaris, D.N.; Lambropoulou, D.A. Dispersive solid phase extraction of 18 PFAS from environmental water samples using a novel MOF-polymeric monolith composite followed by High-Resolution mass spectrometry analysis. Microchem. J. 2024, 207, 111795. [Google Scholar] [CrossRef]
- Song, X.L.; Lv, H.; Liao, K.C.; Wang, D.D.; Li, G.M.; Wu, Y.Y.; Chen, Q.Y.; Chen, Y. Application of magnetic carbon nanotube composite nanospheres in magnetic solid-phase extraction of trace perfluoroalkyl substances from environmental water samples. Talanta 2023, 253, 123930. [Google Scholar] [CrossRef]
- Sun, H.; Yang, Y.; Shen, H.; Hao, Q.; Huang, Q.; Gao, J.; Liu, X.; Zhang, H. Fluorinefunctionalized magnetic amino microporous organic network for enrichment of perfluoroalkyl substances. J. Chromatogr. A 2024, 1722, 464899. [Google Scholar] [CrossRef] [PubMed]
- Ouyang, S.; Liu, G.; Peng, S.; Zheng, J.; Ye, Y.X.; Zheng, J.; Tong, Y.; Hu, Y.; Zhou, N.; Gong, X.; Xu, J.; Ouyang, G. Superficially capped amino metal-organic framework for efficient solid-phase microextraction of perfluorinated alkyl substances. J. Chromatogr. A 2022, 1669, 462959. [Google Scholar] [CrossRef]
- Olomukoro, A.A.; DeRosa, C.; Gionfriddo, E. Investigation of the adsorption/ desorption mechanism of perfluoroalkyl substances on HLB-WAX extraction phases for microextraction. Anal. Chim. Acta 2023, 1260, 341206. [Google Scholar] [CrossRef]
Figure 1.
Structure of PFAS determined in this study: perfluorooctanoic acid (PFOA), perfluorohexanesulfonic acid (PFHxS), and perfluorooctanesulfonic acid (PFOS) (linear isomers).
Figure 1.
Structure of PFAS determined in this study: perfluorooctanoic acid (PFOA), perfluorohexanesulfonic acid (PFHxS), and perfluorooctanesulfonic acid (PFOS) (linear isomers).

Figure 2.
Effects of (A) the capillary coating and (B) the number of draw/eject cycles on the IT-SPME of PFOA, PFHxS, and PFOS (500 pg/mL each). Extraction was performed by drawing and ejecting 40 µL of the mixed standard solution at 200 µL/min with (A) 20 cycles and (B) a Supel-Q PLOT capillary. The enrichment factor is the ratio of the peak height obtained by IT-SPME (1 mL) to that obtained by direct injection (10 µL). Error bars show the standard deviation (n = 3).
Figure 2.
Effects of (A) the capillary coating and (B) the number of draw/eject cycles on the IT-SPME of PFOA, PFHxS, and PFOS (500 pg/mL each). Extraction was performed by drawing and ejecting 40 µL of the mixed standard solution at 200 µL/min with (A) 20 cycles and (B) a Supel-Q PLOT capillary. The enrichment factor is the ratio of the peak height obtained by IT-SPME (1 mL) to that obtained by direct injection (10 µL). Error bars show the standard deviation (n = 3).

Figure 3.
MRM chromatograms of a 50 pg/mL PFAS mixed standard solution obtained by IT-SPME/LC-MS/MS: (upper row) PFOA, PFHxS, and PFOS; (lower row) the corresponding stable isotope-labeled internal standards. Analytical conditions are described in Section 2.
Figure 3.
MRM chromatograms of a 50 pg/mL PFAS mixed standard solution obtained by IT-SPME/LC-MS/MS: (upper row) PFOA, PFHxS, and PFOS; (lower row) the corresponding stable isotope-labeled internal standards. Analytical conditions are described in Section 2.

Figure 4.
MRM chromatograms of a river water sample (No. 6 in Table 4) obtained by IT-SPME/LC-MS/MS: (upper row) PFOA, PFHxS, and PFOS; (lower row) the corresponding internal standards. Analytical conditions are described in Section 2.

Table 1.
Linearity and sensitivity of the IT-SPME LC–MS/MS method for PFAS.
| Compound | Mass transition (m/z) |
Linearity | LOD 2) (pg/mL) | LOQ3) (pg/mL) |
||
|---|---|---|---|---|---|---|
| Range (pg/mL) |
CC 1) (R2) |
Direct injection |
IT-SPME | |||
| PFOA | 413→369 | 1–250 | 0.99983 | 4.14 | 0.085 | 0.38 |
| PFHxS | 399→80 | 1–250 | 0.99999 | 1.31 | 0.058 | 0.23 |
| PFOS | 499→80 | 1–250 | 0.99998 | 8.73 | 0.229 | 0.84 |
1) Correlation coefficient (n = 24); 2) Limits of detection (S/N=3); 3) Limits of quantification (S/N=10).
Table 2.
Precision and accuracy of the IT-SPME LC–MS/MS method for PFAS.
| Compound | Concentration (pg/mL) |
Precision: RSD1) (n=6) | Accuracy (n=6) | ||
|---|---|---|---|---|---|
| Intraday (%) | Interday (%) | Intraday (%) | Interday (%) | ||
| PFOA | 5 | 4.1 | 3.6 | 105.2 | 95.6 |
| 50 | 2.4 | 2.2 | 100.7 | 112.4 | |
| 250 | 3.0 | 2.9 | 98.3 | 100.4 | |
| PFHxS | 5 | 7.2 | 4.0 | 93.0 | 95.7 |
| 50 | 5.8 | 4.8 | 102.1 | 97.0 | |
| 250 | 2.8 | 5.1 | 100.3 | 96.9 | |
| PFOS | 5 | 5.3 | 8.3 | 109.2 | 98.4 |
| 50 | 3.3 | 5.4 | 100.4 | 96.6 | |
| 250 | 5.6 | 3.2 | 96.8 | 95.1 | |
1) RSD: relative standard deviation..
Table 3.
Recoveries and matrix effects of PFAS spiked into tap water and river water.
| Compound | Spiked (pg/mL) |
Tap water | River water | ||
|---|---|---|---|---|---|
| Recovery ± SD1) (%), (n = 3) | Matrix effect (%) |
Recovery ± SD1) (%), (n = 3) | Matrix effect (%) |
||
| PFOA | 5 | 97.8 ± 6.8 | 101.1 | 100.7 ± 9.2 | 100.1 |
| 50 | 97.9 ± 2.6 | 93.0 ± 5.5 | |||
| 250 | 99.5 ± 2.9 | 99.6 ± 1.8 | |||
| PFHxS | 5 | 106.7 ± 5.2 | 96.4 | 94.8 ± 4.4 | 101.3 |
| 50 | 102.5 ± 4.0 | 101.1 ± 3.3 | |||
| 250 | 100.8 ± 3.5 | 101.5 ± 2.9 | |||
| PFOS | 5 | 93.2 ± 7.4 | 100.7 | 102.6 ± 6.9 | 96.7 |
| 50 | 99.2 ± 2.9 | 93.1 ± 3.1 | |||
| 250 | 100.3 ± 3.3 | 96.5 ± 1.2 | |||
1) RSD: relative standard deviation..
Table 4.
Concentrations of PFAS in environmental and drinking water samples collected or purchased in Okayama Prefecture.
Table 4.
Concentrations of PFAS in environmental and drinking water samples collected or purchased in Okayama Prefecture.
| No | Water sample (source) | Concentration (pg/mL, mean ± SD, n = 3) | |||
|---|---|---|---|---|---|
| PFOA | PFHxS | PFOS | Total | ||
| 1 | Lake water (Kojima) | 19.80 ± 0.48 | 0.80 ± 0.03 | 11.49 ± 0.99 | 32.09 |
| 2 | Seawater (Okayama Port) | 19.43 ± 0.29 | 2.25 ± 0.26 | 13.68 ± 1.66 | 35.36 |
| 3 | River water A (downstream) | 28.00 ± 1.39 | 2.04 ± 0.16 | 12.52 ± 1.58 | 42.56 |
| 4 | River water B (downstream) | 10.77 ± 0.38 | 1.85 ± 0.21 | 24.81 ± 3.95 | 37.43 |
| 5 | River water C (midstream) | 21.68 ± 0.09 | 0.82 ± 0.06 | 13.59 ± 1.36 | 36.09 |
| 6 | River water D (midstream) | 22.00 ± 0.37 | 6.70 ± 0.16 | 24.98 ± 3.03 | 53.68 |
| 7 | River water E (midstream) | 5.96 ± 0.09 | 0.73 ± 0.04 | 15.97 ± 1.07 | 22.66 |
| 8 | River water F (upstream) | 15.06 ± 0.26 | 0.94 ± 0.01 | 17.27 ± 0.31 | 33.27 |
| 9 | River water G (upstream) | 9.03 ± 0.70 | 0.98 ± 0.11 | 28.00 ± 1.65 | 38.01 |
| 10 | River water H (upstream) | 14.91 ± 0.12 | 1.17 ± 0.14 | 23.90 ± 0.46 | 39.98 |
| 11 | Sewage treatment effluent | 16.09 ± 0.84 | 2.56 ± 0.33 | 19.82 ± 1.56 | 38.47 |
| 12 | Pond water A | 13.74 ± 0.27 | 1.20 ± 0.09 | 19.32 ± 2.53 | 34.26 |
| 13 | Pond water B | 49.39 ± 1.11 | 3.25 ± 0.30 | 12.20 ± 1.40 | 64.84 |
| 14 | Rainwater | 5.08 ± 0.40 | 1.08 ± 0.11 | 1.20 ± 0.11 | 7.36 |
| 15 | Tap water A (family home) | 6.00 ± 0.51 | 0.44 ± 0.04 | 1.43 ± 0.13 | 7.87 |
| 16 | Tap water B (family home) | 5.62 ± 0.21 | 0.61 ± 0.07 | 24.81 ± 1.62 | 31.04 |
| 17 | Tap water C (family home) | 13.86 ± 0.29 | 0.45 ± 0.02 | 15.04 ± 0.83 | 29.35 |
| 18 | Tap water D (large building) | 20.73 ± 1.17 | 0.68 ± 0.08 | 13.16 ± 0.87 | 34.57 |
| 19 | Tap water E (large building) | 24.67 ± 2.08 | 2.19 ± 0.09 | 15.17 ± 0.37 | 42.03 |
| 20 | Mineral water (Gifu) | 6.89 ± 0.09 | 0.25 ± 0.03 | 31.82 ± 1.47 | 38.96 |
| 21 | Mineral water (Aso) | 8.18 ± 0.11 | 2.99 ± 0.21 | 31.56 ± 1.89 | 42.73 |
| 22 | Mineral water (Rokko) | 5.68 ± 0.36 | 2.71 ± 0.10 | 32.81 ± 1.27 | 41.20 |
| 23 | Mineral water (Kumano) | 6.97 ± 0.44 | 1.01 ± 0.06 | 28.46 ± 0.21 | 36.44 |
| 24 | Mineral water (France) | 12.82 ± 0.36 | 0.68 ± 0.05 | 48.14 ± 1.16 | 61.64 |
| 25 | Sports drink | 40.45 ± 2.07 | 4.16 ± 0.39 | 69.77 ± 2.66 | 114.38 |
| 26 | Barley tea | 53.47 ± 2.66 | 3.83 ± 0.29 | 2.27 ± 0.29 | 59.57 |
| 27 | Green tea | 76.16 ± 1.71 | 4.07 ± 0.38 | 2.45 ± 0.28 | 82.68 |
| 28 | Strong green tea | 38.95 ± 2.19 | 1.20 ± 0.14 | 1.36 ± 0.09 | 41.51 |
1) Total: sum of the mean concentrations of PFOAS, PFHxS, and PFOS.
Table 5.
Main LC-MS/MS-based methods reported since 2022 for the determination of PFAS in environmental and drinking water samples.
Table 5.
Main LC-MS/MS-based methods reported since 2022 for the determination of PFAS in environmental and drinking water samples.
| Sample | Sample volume (mL) | Extraction 1) | Target | Detection | LOD / LOQ 2) (ng/L) | Precision: RSD (%) |
Recovery (%) | Ref. |
|---|---|---|---|---|---|---|---|---|
| Groundwater, surface water, tap water | 50 | None (direct injection) | 51 PFASs | LC- MS/MS | LOQ: 0.65– 10 | 2.1–14.6 | 90.3–119.2 | [61] |
| Surface water | 200 | SPE (Oasis WAX) | 14 PFASs | LC-MS/MS | IDL: 10–90, MDL: 30–750 |
< 20 | 57–121 | [63] |
| Groundwater | 6 | SPE (Strata-X-AW) | 42 PFASs | UHPLC-MS/ MS | MDL: 0.07–1.97, MQL: 0.20– 5.90 |
2.0–23.3 | 51.4 –117.8 | [64] |
| Wastewater | 50 | SPE (Oasis WAX, HLB) | 35 PFASs | UHPLC-MS/MS | MDL: 0.03–756.9, MQL: 0.08– 2293.6 |
1.7–42.6 | 6.3–296.3 | [65] |
| Wastewater | 2 | Online SPE (Oasis WAX) | 40 PFASs | LC-MS/MS | MDL: 0.60–58.6, LOQ: 1.89– 186 |
1.66–20.3 | 83.7–117 | [66] |
| Surface water, tap water |
250 | semi-automated SPE (Strata-X-AW) | 30 PFASs | LC-MS/MS | MDL: 0.01–1.99, IDL: 0.26– 205 |
≤ 20 | 65–128 | [67] |
| Drinking water | 500 | SPE (Oasis WAX, InertSep) | 21 PFASs | LC-MS/MS | LOQ: 1.0 | 1–127 | 1–337 | [62] |
| Drinking water | 100 | SPE (Strata-X-AW) | 22 PFASs | UHPLC-MS/MS | LOQ: 0.025–0.25 | ≤ 20 | 70 –120 | [68] |
| Drinking water | 250 | SPE (Strata-X-AW) | 50 PFASs | LC-MS/MS | LOQ: 0.031–5.1 | 9–12 | 92–99 | [69] |
| Water, beverages | < 10 | PT-SPE (UiO-66-F4/PAN) |
12 PFASs | UHPLC-Orbitrap HRMS |
LOD: 8–76 | < 15 | 70.8–113.6 | [70] |
| Wastewater | 5 | d-SPE (Cr-doped CoFe LDH) |
PFOA | HPLC-MS/MS | LOD: 30 | < 6 | 85–104 | [71] |
| Environmental water | 10 | d-SPE (MOF copolymer) |
18 PFASs | HRMS | LOD: 1–46 | < 20 | 74–146 | [72] |
| Environmental water | 10 | MSPE (MWCNTs@Fe3O4@C) |
6 PFASs | LCMS/MS | LOD: 0.03–0.09, LOQ: 0.1–0.3 |
3.80–9.52 | 4.0 –103.5 | [73] |
| Environmental water | 20 | MSPE (Fe3O4@MON–NH2@F7) |
9 PFASs | UHPLC-Orbitrap HRMS | LOD: 0.54–1.47 | < 9.1 | 81.7–121.6 | [74] |
| Environmental water | 8 | Fiber SPME (NH2-UiO-66(Zr)-hp) |
11 PFASs | HPLC-MS/MS | LOD: 0.035–0.616 | <11.2 | 80.9–120 | [75] |
| Environmental water | 1.5 | Fiber and thin film SPME (HLB-WAX) |
15 PFASs | HPLC-MS/MS | LOD: 2.5–10 | < 15 | 70–130 | [76] |
| Environmental water, drinking water | 0.5 | Online IT-SPME (Supel-Q PLOT) |
PFOA, PFHxS, PFOS | LC–MS/MS | LOD: 0.06‒0.23, LOQ: 0.23‒0.84 |
2.2‒8.3 | 93‒107 | This study |
1) SPE: solid phase extraction; PT-SPE: pipette tip SPE; d-SPE: dispersive SPE; MSPE: magnetic SPE; SPME: solid phase microextraction; IT-SPME: in-tube SPME. 2) IDL: instrumental detection limit; MDL: method detection limit; IQL: instrumental quantitation limit; MQL: method quantification limit.
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
Copyright: This open access article is published under a Creative Commons CC BY 4.0 license, which permit the free download, distribution, and reuse, provided that the author and preprint are cited in any reuse.