Magnetron-Sputtered TaCu and NbCu Coatings on 3D-Printed Titanium Implants: Implant Retention Following Staphylococcus aureus Challenge

Submitted:

03 November 2026

Posted:

04 November 2026

You are already at the latest version

Abstract

Background/Objectives: Periprosthetic infection remains a major challenge in orthopedic implantation, particularly for porous titanium implants that promote bone integration but may also facilitate bacterial colonization. This study evaluated magnetron-sputtered tantalum–copper (TaCu) and niobium–copper (NbCu) coatings on Ti6Al4V implants following Staphylococcus aureus challenge, with particular attention to implant geometry. Methods: TaCu-coated, NbCu-coated, and uncoated Ti6Al4V implants with dense (smooth) or porous (rough) geometries were evaluated. Cytocompatibility was assessed using rat mesenchymal stromal cells exposed to implant-conditioned media, and Cu release was measured by ICP-MS. Twenty-four rabbits received femoral implants followed by local S. aureus inoculation. Outcomes were assessed by clinical observation, macroscopic examination, radiography, and confocal microscopy. DAPI-positive structures were analyzed three-dimensionally using a 100 μm³ volume threshold and sensitivity analysis. Results: Neither TaCu- nor NbCu-conditioned media adversely affected MSC metabolic activity, and both coatings released measurable Cu. Despite infection across groups, TaCu-coated implants showed the greatest preservation of implant retention. Analysis of 6,248 segmented objects from 21 animals showed significant associations of coating and implant geometry with the proportion of small DAPI-positive objects (both p < 0.001). Uncoated Ti6Al4V showed higher proportions than NbCu and TaCu (Holm-adjusted p < 0.001), whereas TaCu and NbCu did not differ (p = 0.731). Rough implants showed higher proportions than smooth implants, and the coating-related pattern persisted across thresholds of 25–200 μm³. An additional analysis using a 5 µm³ threshold confirmed differences in the relative proportions of very small DAPI-positive objects (p = 0.0156), whereas total volumetric object density did not differ significantly among coating groups (p = 0.769). Conclusions: Cu-containing coatings altered the distribution of implant-associated DAPI-positive structures without adversely affecting MSC metabolic activity. TaCu showed the greatest preservation of implant retention despite a confocal profile comparable to NbCu, supporting further investigation of TaCu for infection-resistant orthopedic implants.

Keywords: 
;  ;  ;  ;  ;  ;  ;  

1. Introduction

Periprosthetic joint infection (PJI) remains one of the most serious complications of orthopedic implantation and a major cause of failure following total joint arthroplasty. Although PJI affects only a minority of primary arthroplasties, its clinical consequences are disproportionate to its incidence, frequently requiring prolonged antimicrobial therapy, surgical debridement, implant revision, or staged reimplantation. These procedures impose substantial morbidity on patients and a considerable economic burden on healthcare systems, with treatment of septic revisions being substantially more costly than that of aseptic revisions [1,2]. The management of PJI is particularly challenging because many causative microorganisms readily colonize implant surfaces and form biofilms, which promote bacterial persistence and reduce susceptibility to antimicrobial treatment and host defense mechanisms [3]. Staphylococci predominate among orthopedic implant-associated infections, with Staphylococcus aureus and coagulase-negative staphylococci representing particularly important causative organisms [3,4]. Once a mature biofilm is established on an implant surface, eradication becomes difficult without surgical intervention, emphasizing the importance of strategies that limit bacterial attachment and early colonization.
At the same time, advances in additive manufacturing have substantially expanded the possibilities for orthopedic implant design. Ti6Al4V is widely used for load-bearing biomedical implants because of its favorable mechanical properties, corrosion resistance, and established clinical use. Additive manufacturing enables the fabrication of implants with controlled porous architectures that can reduce stiffness mismatch while providing interconnected structures favorable for cellular attachment, nutrient transport, bone ingrowth, and mechanical interlocking. Experimental evidence and systematic reviews indicate that appropriately designed porous titanium structures promote osteogenic cell adhesion and can support bone–implant integration [5,6]. However, the biological advantages of increased surface area and structural complexity may be accompanied by increased opportunities for bacterial attachment and retention. Porous and topographically complex surfaces can provide additional available surface area and protected microenvironments for bacterial colonization, and differences in staphylococcal biofilm formation between flat and porous titanium surfaces have been demonstrated experimentally [7,8]. Thus, implant architecture presents an inherent design challenge: structural features intended to promote bone integration may simultaneously create conditions favorable for bacterial persistence.
Surface modification provides an attractive approach to address this challenge without substantially altering the bulk mechanical properties of titanium implants. Among the numerous strategies investigated, copper-containing surfaces have received considerable attention because of their broad antimicrobial activity and potential applicability to orthopedic biomaterials [9,10]. The antibacterial action of Cu is multifactorial and has been associated with disruption of bacterial membrane integrity, disturbance of intracellular metal homeostasis and enzyme function, generation of reactive oxygen species, and damage to cellular macromolecules [10,11]. In Cu-bearing titanium materials, Cu release and surface-associated interactions can contribute to antibacterial activity against clinically relevant organisms, including S. aureus [10,11]. However, Cu is biologically active toward both microbial and mammalian cells, making control of its concentration and release behavior important. The design of Cu-containing implant surfaces therefore requires a balance between antimicrobial efficacy and preservation of host-cell compatibility [9,12].
Magnetron sputtering offers a versatile approach for incorporating Cu into implant surfaces because coating composition and thickness can be controlled while retaining the underlying mechanical characteristics of the implant. Of particular interest are coating systems in which Cu is combined with metals possessing favorable properties for orthopedic applications. Tantalum (Ta) is characterized by high corrosion resistance and biocompatibility and has been extensively investigated for its ability to support osteogenic responses and bone integration [13]. Niobium (Nb) is likewise attractive for biomedical applications because of its chemical stability, corrosion resistance, and favorable cellular and bone-tissue responses [14]. Combining Cu with Ta or Nb therefore provides a strategy for integrating antimicrobial functionality with a stable metallic coating matrix, while avoiding modification of the bulk Ti6Al4V implant.
In our previous studies, magnetron-sputtered TaCu and NbCu coatings were developed and characterized on Ti6Al4V substrates, including additively manufactured porous scaffolds [15,16]. Coatings containing approximately 25 at.% Cu and with thicknesses of 2 and 10 μm were successfully deposited on porous Ti6Al4V scaffolds, establishing the feasibility of applying these coating systems to complex three-dimensional implant architectures [15]. Subsequent antimicrobial evaluation demonstrated activity of the TaCu and NbCu coating systems against S. aureus and Candida albicans, with coating thickness influencing antimicrobial performance; thin NbCu coatings and uncoated Ti6Al4V showed no detectable inhibition under the tested conditions [16]. Cu release from TaCu-coated specimens was additionally monitored over 10 days by ICP-MS, and its temporal profile corresponded to changes in antimicrobial activity [16]. Complementary studies of Ta–Cu thin films further demonstrated that antibacterial performance depends strongly on Cu content and coating-processing conditions [17].
However, in vitro antimicrobial activity alone cannot establish whether a coating will preserve implant performance within the substantially more complex environment of an implant-associated infection, where bacterial colonization, host responses, implant architecture, and peri-implant tissue damage occur simultaneously. Moreover, it remains unclear whether microscopic differences in implant-associated bacteria-sized structures correspond to functional outcomes such as implant retention. Therefore, the present study investigated the biological performance of magnetron-sputtered TaCu and NbCu coatings on dense and porous Ti6Al4V implants using complementary in vitro and in vivo approaches. We assessed MSC responses to implant-conditioned media, Cu release, implant-associated outcomes following an experimental S. aureus challenge, and the three-dimensional distribution of implant-associated DAPI-positive structures. Particular attention was given to whether coating composition and implant geometry were associated with microscopic surface-related changes and whether these changes corresponded to preservation of implant retention under infection-challenged conditions.

2. Materials and Methods

2.1. Preparation of Titanium Implants

Porous (“rough”) Ti6Al4V implants were fabricated by selective laser melting (Mlab cusing R, Concept Laser, Germany) from medical-grade Ti6Al4V alloy (Grade 23, ISO 5832-3). The implants were manufactured as cylindrical discs (6 mm diameter, 3 mm thickness) with a regular lattice architecture, an average pore diameter of approximately 670 μm, and an overall porosity of 72%. Dense (“smooth”) control specimens were prepared from Ti6Al4V rods using CNC machining and had identical dimensions (6 mm × 3 mm). Uncoated Ti6Al4V implants served as the control group.
Prior to coating deposition, all specimens were ultrasonically cleaned in distilled water, acetone, and medical-grade ethanol for 30 min in each solution, followed by air drying.

2.2. Magnetron Sputtering of TaCu and NbCu Coatings

TaCu and NbCu coatings were deposited using an EPOS-PVD-440 magnetron sputtering system (Beams&Plasmas, Novosibirsk, Russia) equipped with three direct-current magnetrons and an ion source. High-purity Ta, Nb, and Cu rectangular targets were used for simultaneous dual-magnetron co-sputtering. During deposition, the specimens were mounted on a rotating substrate holder (8 rpm) to ensure uniform coating deposition over both dense and porous implant surfaces.
The chamber was evacuated to a base pressure of 7 × 10⁻⁴ Pa before introducing argon as the working gas to an operating pressure of 0.2 Pa. Deposition was performed without intentional substrate heating, the rotation speed of the substrate holder was 7.5 revolutions per minute. The magnetron currents, voltages, sputtering distance, deposition time, and argon flow rate are summarized in Table 1.
The deposition parameters were selected based on our previous optimization studies to obtain homogeneous TaCu and NbCu coatings containing approximately 25 at.% Cu, with a target thickness of approximately 2 µm, while maintaining uniform elemental distribution and strong adhesion to the Ti6Al4V substrate. Detailed optimization of the sputtering process and coating composition has been reported previously [15,16,17].

2.3. Coating Characterization

The microstructure, thickness, and elemental composition of the deposited coatings were characterized using a BX51 optical microscope (Olympus, Tokyo, Japan) and a JSM-6390LV scanning electron microscope (JEOL, Tokyo, Japan) equipped with an energy-dispersive X-ray spectroscopy (EDX) system (INCA ENERGY, Oxford Instruments, UK). Surface morphology of TaCu- and NbCu-coated porous implants was examined by SEM. Coating thickness was evaluated from cross-sectional images. Under the selected deposition conditions, the TaCu and NbCu coatings had an average thickness of approximately 2 μm. Detailed characterization of the coating structure and elemental composition has been reported previously [15,16,17].

2.4. In Vitro Biocompatibility Assessment

The in vitro biocompatibility of the implants was evaluated using a Cell Counting Kit-8 (CCK-8) assay (96992, Sigma-Aldrich). Implant-conditioned media were prepared by incubating each implant individually in 300 µL of growth medium for 72 h at 37 °C. For smooth cylindrical implants (6 mm in diameter and 3 mm in height), the calculated geometric surface-area-to-extraction-medium volume ratio was approximately 3.77 cm²/mL. The same extraction volume was used for porous implants, although their actual accessible surface area was not quantified. Rat mesenchymal stromal cells (MSCs) (Sigma-Aldrich, SCR027) were seeded into 96-well plates at a density of 5 × 10³ cells per well in 100 μL of the corresponding implant-conditioned medium and cultured for 24 h. The extract obtained from each implant was distributed among three wells (100 µL per well). Cells cultured in standard growth medium without exposure to implant extracts served as the control. After 24 h of exposure, 10 μL of CCK-8 reagent was added to each well, followed by incubation for 4 h. Absorbance was measured at 450 nm using a Synergy H1 microplate reader (BioTek, USA). Cell metabolic activity was compared among the experimental and control groups based on the measured absorbance values. The assay was performed in technical triplicates and repeated in three independent experiments.

2.5. Copper Ion Release

Copper ion release from TaCu- and NbCu-coated Ti6Al4V implants with both porous (rough) and dense (smooth) geometries was evaluated using inductively coupled plasma mass spectrometry (ICP-MS). Implants were immersed in 0.9% NaCl solution and maintained at 37 °C using a SNOL 67/350 laboratory oven (Umega Group AB, Ukmergė, Lithuania). At predetermined time points (1, 2, 3, 7, and 10 days), the immersion medium was collected for analysis and replaced with fresh 0.9% NaCl solution. The Cu concentration in the collected medium was measured using an Agilent 7500cx ICP-MS system (Agilent Technologies, Wilmington, DE, USA). Copper concentrations were converted from µg/L to mmol/L using the molar mass of copper (63.546 g/mol), and the results are presented in mmol/L.

2.6. Animals and Experimental Design

Twenty-four healthy five-month-old Butterfly rabbits (12 males and 12 females; mean body weight approximately 3 kg) were used in this study. Animals were housed under standard laboratory conditions with a 12 h light/12 h dark cycle at 22–23 °C and had free access to food and water. Following acclimatization, the animals were allocated using stratified randomization based on sex and body weight, with random assignment performed using a random number generator, to three experimental groups (n = 8 per group) according to the surface composition of the implanted titanium samples. Each coating group comprised four males and four females. Group I (NbCu, n = 8) received titanium implants coated with NbCu by magnetron sputtering. Group II (TaCu, n = 8) received titanium implants coated with TaCu by magnetron sputtering. Group III (control, n = 8) received uncoated VT-6 (Ti6Al4V) titanium alloy implants. Each group included two implant geometries: rough braided cylindrical cages (n = 4) and smooth solid cylinders (n = 4). Thus, each combination of surface composition and implant geometry was represented by four animals (Figure 1). Implants were surgically placed into a standardized defect created in the distal femoral metaphysis, followed by intraoperative inoculation with Staphylococcus aureus to establish a localized implant-associated infection model. The individual rabbit was the experimental unit. The sample size was determined by the exploratory nature of the study, the design comprising three surface compositions and two implant geometries, and ethical considerations aimed at minimizing animal use. All 24 rabbits were initially included, and no formal a priori exclusion criteria were established
All procedures were approved by the Local Ethics Committee of the National Scientific Center of Traumatology and Orthopedics named after Academician N.D. Batpenov (Approval No. 1, March 28, 2022) and performed in accordance with national regulations governing biomedical research involving animals. Radiographic and confocal microscopy assessments were performed by investigators blinded to coating-group allocation. Investigators assessing implant retention and analyzing confocal microscopy data were unaware of the coating type assigned to each sample during outcome assessment.

2.7. Preparation of the Bacterial Inoculum

Staphylococcus aureus (S. aureus) was used to establish an experimental implant-associated infection. The bacterial strain was provided by the Bacteriological Laboratory of the National Scientific Center of Traumatology and Orthopedics named after Academician N.D. Batpenov (Astana, Kazakhstan). The inoculum was prepared from a pure 24-h culture of S. aureus grown on solid culture medium. Several morphologically similar, well-isolated colonies were collected using a sterile inoculation loop and suspended in sterile saline. The turbidity of the suspension was adjusted to a 0.5 McFarland standard, corresponding to approximately 1.0 × 10⁸ CFU/mL. Immediately after implant placement, 0.5 mL of the freshly prepared bacterial suspension was applied directly to the implant and surrounding tissues at the surgical site, corresponding to an estimated bacterial challenge of 5 × 10⁷ CFU per implantation site.

2.8. Surgical Procedure and Implantation

Implantation procedures were performed at the National Scientific Center of Traumatology and Orthopedics named after Academician N.D. Batpenov (Astana, Kazakhstan). Prior to surgery, the animals were premedicated with 1% diphenhydramine (0.1 mg/kg) and 0.1% atropine (1 mg/kg). General anesthesia was induced using Zoletil (20 mg/kg) in combination with xylazine (5 mg/kg). To avoid potential confounding effects on the experimental assessment of bacterial colonization and biofilm formation, perioperative antibiotic prophylaxis and antiseptic treatment of the surgical site were not performed. After induction of anesthesia, a bone defect corresponding to the dimensions of the implant was created in the femoral metaphysis using a portable orthopedic drill operated at low speed under continuous irrigation with sterile 0.9% NaCl solution to minimize thermal injury. The defect was subsequently adjusted manually to achieve tight press-fit fixation of the implant. Depending on the experimental group, either NbCu-coated, TaCu-coated, or uncoated VT-6 (Ti6Al4V) control implants were inserted into the prepared defect. Cylindrical titanium implants (6 mm in diameter and 3 mm in height), with either smooth or porous surface configurations, were implanted into the distal femoral metaphysis of rabbits. The implantation site was selected so that the implants were in direct contact with bone while also remaining partially exposed to the adjacent soft tissues, including muscle, fascia, and connective tissue, allowing assessment of both bone and peri-implant soft-tissue responses. Following implantation, the implant and surrounding tissues were inoculated with a S.aureus suspension at a concentration of 1.0 × 10⁸ CFU/mL. The wound was subsequently closed in layers using Vicryl 6/0 sutures for the deeper tissues and nylon 6/0 sutures for skin closure. Postoperative analgesia was administered subcutaneously using buprenorphine (0.025 mg/kg every 12 h for three days) and carprofen (3 mg/kg once daily for five days). Following surgery, animals were monitored for changes in general condition, behavior, locomotor activity, food intake, body weight, and clinical signs of distress. Overall, animals were monitored for three weeks following implantation. At the end of the observation period, surviving animals were euthanized, and the implantation sites, implants, and surrounding tissues were collected for subsequent analyses. Outcome assessment included survival monitoring, macroscopic evaluation of the implantation site and implant retention, radiographic assessment of implant position and surrounding bone architecture, and three-dimensional confocal imaging with object-based analysis of implant-associated DAPI-positive structures. The predefined humane endpoints included body weight loss exceeding 20% of baseline, complete anorexia lasting more than 48 h, and clinical signs of severe gastrointestinal stasis. Additional criteria for humane euthanasia included severe pain unresponsive to analgesic treatment. Postoperative monitoring was performed daily until the scheduled three-week endpoint or premature death.

2.9. Radiographic Assessment

Radiographic examination of the operated femur was performed three weeks after implantation in all animals surviving to the scheduled examination time point to evaluate implant position and peri-implant bone changes. In animals that died before this time point, radiographic examination was performed earlier, following death. Implant position was classified as a binary animal-level outcome based on its location relative to the original distal femoral implantation site. An implant was classified as retained when it remained localized within the implantation site and as displaced when radiographic examination demonstrated migration from the original implantation site. Each animal was classified once according to this criterion. Additional peri-implant bone changes were evaluated descriptively because no predefined quantitative radiographic scoring system was applied.

2.10. DAPI Staining and Confocal Microscopy

At specimen collection, metal–bone specimens containing the implanted material and adjacent tissue were collected for confocal microscopy. To preserve the surface-associated biological material, specimens were not treated with disinfectants or chemical fixatives prior to analysis. Each specimen was rinsed with phosphate-buffered saline (PBS), incubated for 15 min with 1 μM DAPI in PBS, and subsequently washed twice with PBS. Samples were examined using an LSM 780 confocal laser scanning microscope (Carl Zeiss, Germany) at 20X magnification with 1.5X zoom and 405 nm excitation. Z-stack images were acquired for each specimen and recon-structed as three-dimensional projections for assessment of surface-associated DAPI-positive material. Confocal microscopy was performed on specimens available from 21 animals. Three of the 24 animals were excluded from quantitative confocal analysis because of unexpected postoperative death before sample collection. These exclusions were not based on predefined exclusion criteria.

2.11. Three-Dimensional Reconstruction and Object-Based Analysis

Confocal Z-stack images of DAPI-stained implant-associated structures were subjected to three-dimensional reconstruction and object-based analysis using Imaris software (Bitplane, Oxford Instruments). Image stacks were reconstructed in three dimensions, and DAPI-positive structures were segmented using the Imaris Surfaces module. Segmentation parameters were applied consistently across experimental groups to minimize operator-dependent variability. Individual segmented objects were quantified based on their reconstructed three-dimensional volume (μm³).
For quantitative analysis, segmented DAPI-positive objects were classified according to their reconstructed volume using a predefined threshold of 100 μm³. The 100 µm³ threshold was used as an operational cutoff for morphometric stratification of segmented objects and was not intended to distinguish bacterial cells from host-derived structures. Objects with a volume <100 μm³ were classified as small DAPI-positive structures, whereas objects with a volume ≥100 μm³ were classified as large DAPI-positive structures. For each animal, the proportion of small objects was calculated as the number of objects <100 μm³ divided by the total number of segmented DAPI-positive objects and expressed as a percentage.
Because DAPI labels DNA irrespective of cellular origin and is not specific for bacterial cells, object size was used as a morphological classification parameter rather than as a definitive marker of bacterial or mammalian cell identity. To evaluate whether the observed group differences were dependent on the selected 100 μm³ cutoff, a sensitivity analysis was additionally performed by recalculating the proportion of small DAPI-positive objects across volume thresholds ranging from 25 to 200 μm³.

2.12. Statistical Data Analysis

Data from the CCK-8 assay and Cu-release experiments are presented as mean ± SD. Differences in CCK-8 metabolic activity among experimental groups were analyzed using one-way ANOVA followed by Dunnett’s multiple-comparisons test, with each implant-conditioned medium group compared with the control group. Statistical significance was defined as p < 0.05. For in vivo analyses individual animals were considered the biological experimental units. Radiographic implant position was analyzed as a binary outcome (retained versus displaced). The overall association between coating type and implant retention was evaluated using the Fisher–Freeman–Halton exact test, followed by pairwise Fisher’s exact tests with Holm adjustment for multiple comparisons. All 24 animals contributed to mortality and radiographic implant-retention reporting (n = 8 per coating group). Individual segmented objects were subsamples within animals and were not treated as independent biological replicates.
For the confocal analysis, the primary outcome was the animal-level proportion of small DAPI-positive objects with reconstructed volumes <100 μm³. Because this outcome was expressed as a continuous proportion bounded between 0 and 1, it was analyzed using beta regression with a logit link. Implant coating (NbCu, TaCu, or uncoated Ti6Al4V) and implant geometry (smooth or rough) were included as explanatory variables. A coating × geometry interaction was initially evaluated and was excluded from the final additive model because it did not significantly improve model fit. Overall effects of coating and geometry were assessed using likelihood-ratio tests. Pairwise comparisons among coating groups were performed on the model scale with Holm adjustment for multiple comparisons. Robustness of the predefined 100 μm³ threshold was assessed using thresholds of 25, 50, 75, 100, 125, 150, and 200 μm³. To further assess the influence of the selected volume threshold, an additional analysis was performed using a more restrictive cutoff of 5 µm³. Objects below this threshold were classified as very small DAPI-positive structures. This cutoff was used exclusively for morphometric analysis and was not considered evidence of bacterial identity. In addition to relative object-size distributions, the absolute volumetric density of DAPI-positive objects was calculated for each animal. Three-dimensional segmentation was performed across the entire confocal image stack without restricting the analysis to a selected region of interest. The XY field of view was 283.397 × 283.397 µm, and the Z-step was 1 µm, as verified from the original image acquisition metadata. Because the number of optical sections varied among samples, the analyzed volume was calculated individually by multiplying the XY field area by the number of Z-sections and the Z-step. Total object density and the densities of objects smaller than 5 and 100 µm³ were calculated by dividing the corresponding object counts by the analyzed imaging volume and expressed as objects/mm³. Beta-regression analyses were performed using Python with Statsmodels (version 0.14.6). All tests were two-sided, and p < 0.05 was considered statistically significant. Additional exploratory analyses were performed using the animal-level proportion of DAPI-positive objects smaller than 5 µm³ and the absolute volumetric densities of segmented objects. Differences among coating groups were assessed using the Kruskal–Wallis test, followed by pairwise Mann–Whitney U tests with Holm adjustment where applicable. The potential effects of coating composition and implant geometry were further evaluated using exploratory two-factor linear models, with logarithmic transformation applied to object-density outcomes. These supplementary analyses were conducted at the animal level to avoid treating individual segmented objects as independent biological replicates.

3. Results

3.1. In Vitro Cytocompatibility of TaCu- and NbCu-Coated Implants

The potential cytotoxic effects of the implant surfaces were evaluated by measuring the metabolic activity of rat MSCs following 24 h exposure to implant-conditioned media. CCK-8 absorbance values were comparable among cells exposed to conditioned media from TaCu-coated, NbCu-coated, and uncoated Ti6Al4V implants and cells maintained in standard growth medium (Figure 2b). No statistically significant differences were detected among the experimental and control groups (p > 0.05). These results indicate that soluble components released from the TaCu- and NbCu-coated implants did not adversely affect MSC metabolic activity under the tested conditions.

3.2. Copper Release from TaCu and NbCu Coatings

Copper release from TaCu- and NbCu-coated implants with both porous (rough) and dense (smooth) geometries were monitored over a 10-day immersion period at 37 °C (Figure 2c). Cu was detected in the immersion medium from both coating types and implant geometries at all analyzed time points (days 1, 2, 3, 7, and 10), whereas concentrations remained negligible in the uncoated Ti6Al4V controls. The coated implants exhibited a time-dependent release profile, with the highest Cu concentrations observed during the early phase of immersion followed by progressively lower concentrations at later time points. Overall, the release profiles differed according to both coating composition and implant geometry.

3.3. Animal Outcomes and Macroscopic Evidence of Infection Following S. aureus Challenge

Animals were monitored daily following surgery until the scheduled experimental endpoint or premature death. Seven of the 24 rabbits died prematurely during postoperative follow-up: three in the NbCu group (postoperative days 2, 6, and 11), one in the TaCu group (day 2), and three in the uncoated Ti6Al4V group (days 3, 6, and 9). None of these animals had met the predefined humane endpoint criteria before death, and no animals underwent early euthanasia because of humane endpoint criteria. By coating group, mortality was 3/8 (37.5%) in the NbCu group, 1/8 (12.5%) in the TaCu group, and 3/8 (37.5%) in the uncoated Ti6Al4V group. When considered according to implant geometry, mortality was 3/12 (25.0%) for smooth implants and 4/12 (33.3%) for rough implants. Given the small group sizes, these observations were considered descriptive and were not interpreted as evidence of coating- or geometry-dependent differences in mortality. Macroscopic examination of the implantation sites demonstrated evidence of infection across all three experimental groups, indicating that neither Cu-containing coating completely prevented infection under the applied bacterial challenge.

3.4. Implant Retention and Radiographic Findings Following S. aureus Challenge

Radiographic assessment demonstrated marked differences in implant retention among the three surface conditions. All TaCu-coated implants remained localized within the distal femoral implantation site (8/8, 100%), whereas displacement was observed in 4/8 (50%) NbCu-coated implants and in all 8/8 (100%) uncoated Ti6Al4V implants. The overall association between coating type and radiographic implant retention was significant (Fisher–Freeman–Halton exact test, p = 0.00016). Pairwise Fisher’s exact tests with Holm correction showed a significant difference between TaCu-coated and uncoated Ti6Al4V implants (adjusted p = 0.00047), whereas TaCu versus NbCu and NbCu versus uncoated Ti6Al4V did not reach statistical significance (adjusted p = 0.154 for both comparisons).
Representative radiographs illustrate retained and displaced implants (Figure 3). In animals with retained implants, the implant remained localized within the distal femoral implantation site, whereas displaced implants had migrated from the implantation site, in some cases accompanied by pronounced disruption of the surrounding bone architecture. Peri-implant bone changes were interpreted descriptively because they were not evaluated using a predefined quantitative radiographic scoring system. These results include radiographs obtained at the scheduled three-week assessment in survivors and earlier postmortem examinations in animals that died prematurely; they therefore represent implant status at each animal’s examination time rather than a uniform three-week endpoint for all animals.

3.5. Three-Dimensional Analysis of Implant-Associated DAPI-Positive Structures

Three-dimensional object-based analysis included 6,248 segmented DAPI-positive objects obtained from 21 animals. The reconstructed objects exhibited a broad distribution of volumes, with both small (<100 μm³) and large (≥100 μm³) structures detected across the experimental groups (Figure 4a, b).
The animal-level proportion of small DAPI-positive objects was significantly associated with implant coating (beta regression, p < 0.001; Figure 4c). Median proportions were 80.9% for NbCu-coated implants, 88.0% for TaCu-coated implants, and 95.1% for uncoated Ti6Al4V implants. Post hoc model-based pairwise comparisons with Holm correction demonstrated higher proportions of small DAPI-positive objects in uncoated Ti6Al4V implants than in both NbCu-coated (adjusted p = 0.00012) and TaCu-coated implants (adjusted p < 0.0001). No difference was detected between TaCu- and NbCu-coated implants (adjusted p = 0.731).
Implant geometry was also significantly associated with the proportion of small DAPI-positive objects (beta regression, p < 0.001; Figure 4d), with rough implants exhibiting a greater proportion of small objects than smooth implants. No significant coating-by-geometry interaction was detected (p = 0.183), providing no evidence that the association between coating and small-object proportion differed according to implant geometry.
Sensitivity analysis across object-volume thresholds ranging from 25 to 200 μm³ showed that the coating-related pattern was maintained throughout the evaluated range. Uncoated Ti6Al4V implants consistently exhibited the highest median proportion of small DAPI-positive objects (Figure A1) indicating that the observed group differences were not dependent on the selected 100 μm³ threshold.
To further evaluate the distribution of very small DAPI-positive structures, an additional analysis was performed using a more restrictive volume threshold of 5 µm³. Of the 6,248 segmented objects, 3,948 (63.2%) had reconstructed volumes below 5 µm³. The median animal-level proportions of these objects were 52.6%, 49.2%, and 71.2% for NbCu-coated, TaCu-coated, and uncoated Ti6Al4V implants, respectively (Figure 4f). The proportions differed significantly among coating groups (Kruskal–Wallis test, p = 0.0156). Holm-adjusted pairwise comparisons indicated higher proportions in the uncoated Ti6Al4V group than in either coated group (adjusted p = 0.038 for both comparisons), whereas no significant difference was detected between NbCu and TaCu. To distinguish relative object-size distributions from absolute object abundance, the volumetric density of segmented DAPI-positive structures was calculated for each animal. Median total object densities were 34,498 objects/mm³ for NbCu-coated implants, 29,521 objects/mm³ for TaCu-coated implants, and 48,928 objects/mm³ for uncoated Ti6Al4V implants (Figure 4e). No statistically significant difference in total object density was detected among coating groups (Kruskal–Wallis test, p = 0.769). Similarly, the densities of objects smaller than 5 and 100 µm³ did not differ significantly among groups (p = 0.297 and p = 0.552, respectively). Thus, the coating-associated differences observed in the relative proportions of small DAPI-positive structures were not accompanied by statistically significant differences in their absolute volumetric densities.

4. Discussion

The present study evaluated the biological performance of magnetron-sputtered TaCu and NbCu coatings on Ti6Al4V implants using complementary in vitro and in vivo approaches, including an experimental Staphylococcus aureus infection challenge. Several findings are particularly relevant. First, conditioned media generated from both Cu-containing coatings did not adversely affect MSC metabolic activity under the tested conditions. Second, both coatings released measurable Cu during immersion, confirming the availability of a potentially biologically active component at the implant–environment interface. Third, although infection developed following the deliberately introduced bacterial challenge, implant-associated outcomes differed substantially among the tested surfaces, with TaCu-coated implants showing the greatest preservation of implant retention. Finally, three-dimensional object-based analysis demonstrated that both Cu-containing coatings were associated with a lower relative proportion of small DAPI-positive structures than uncoated Ti6Al4V, while implant geometry was also associated with their distribution. Notably, the similar confocal profiles of TaCu and NbCu contrasted with their different implant retention outcomes, indicating that these microscopic and functional endpoints did not fully coincide.
The incorporation of Cu into implant materials requires a balance between antimicrobial activity and compatibility with host cells, because the same ion-release process that contributes to antibacterial activity may become detrimental at excessive local concentrations. Previous studies of Cu-containing titanium materials have demonstrated that antibacterial activity can coexist with acceptable cellular responses. Liu et al. reported that a sintered Ti–Cu alloy exhibited strong antibacterial activity against S. aureus and Escherichia coli, while CCK-8 analysis showed no detectable cytotoxicity compared with commercially pure titanium; measurable Cu release was also demonstrated during immersion [12]. In the present study, exposure to media conditioned by TaCu- and NbCu-coated implants similarly did not significantly alter MSC metabolic activity compared with the controls, indicating no detectable adverse effect of soluble coating-derived components under the conditions examined. These findings support the concept that controlled incorporation of Cu into titanium-based implant materials can provide antimicrobial functionality without necessarily compromising host-cell metabolic activity.
The time-dependent Cu release observed from the TaCu and NbCu coatings represents an important component of their biological behavior. Cu-containing titanium materials have previously demonstrated ion release associated with antibacterial activity [9,10,11,12]. In our previous work, magnetron-sputtered Ta–Cu and Nb–Cu coatings exhibited antibacterial activity against several bacterial species, including S. aureus, while coating thickness and Cu release influenced their antimicrobial performance [15,16]. Additional experiments with Ta–Cu thin films demonstrated that Cu content and thermal treatment substantially affected antibacterial activity [17]. Related TaCuN coatings produced by reactive magnetron co-sputtering also demonstrated Cu-dependent antibacterial activity against S. aureus, with the formulation containing the highest Cu content producing approximately 97% bacterial reduction after 24 h [18]. However, greater Cu availability should not automatically be interpreted as biologically preferable. Hoene et al. demonstrated measurable Cu release from Cu-coated titanium implants in vivo and an increased local macrophage response around Cu-containing implants [19]. Thus, the absence of a detectable adverse effect on MSC metabolic activity in the present extract-based assay is encouraging, but the biological consequences of Cu release should be considered together with local tissue responses rather than interpreted as evidence that increasing Cu release would necessarily improve implant performance.
The selection of a coating thickness of approximately 2 µm was informed by our previous investigations of magnetron-sputtered copper-containing coatings on Ti6Al4V substrates. In particular, Alontseva et al. demonstrated that TaCu coatings with a thickness of approximately 2 µm retained antibacterial activity against Staphylococcus aureus in vitro, whereas increasing the coating thickness to approximately 10 µm resulted in larger inhibition zones [20]. These findings supported the selection of a thinner coating configuration with 25 at.% Cu for further investigation, considering the potential trade-off between copper-mediated antimicrobial activity and cytotoxicity associated with increased copper release. Our previous investigations of TaCu and NbCu coatings demonstrated that antibacterial performance was dependent on coating composition and thickness, with thin NbCu coatings failing to produce detectable bacterial inhibition under the tested in vitro conditions [15,16]. However, the parameters of MS and corresponding coating composition differed from the parameters chosen in this study. Thus, the selection of a 2 µm coating in the present study represented an experimental choice rather than an established optimum for antibacterial performance.
The in vivo infection model provided a more stringent test of coating performance. The experimental S. aureus challenge resulted in evidence of infection across the implant groups, indicating that neither Cu-containing coating completely prevented establishment of infection under the conditions used. This finding does not necessarily contradict previous evidence of antibacterial activity of Cu-containing titanium materials, because the outcome of an infection model depends on material composition, Cu availability, bacterial strain and inoculum, and experimental design. Zhuang et al. demonstrated pronounced antibacterial activity of a Cu-containing Ti6Al4V alloy in a rat model of MRSA-associated implant infection, with reduced infection-related changes compared with conventional Ti6Al4V [21]. Importantly, the present model involved direct application of a high S. aureus inoculum to the implant and surrounding tissues, representing a severe local infection challenge. Under these conditions, the most notable finding was therefore not complete suppression of infection, but the differential ability of the implants to remain retained at the implantation site within the infected environment.
The preservation of implant retention observed with TaCu is particularly noteworthy. Although Cu provides an established antimicrobial component, the difference between TaCu and NbCu cannot readily be attributed to Cu alone, particularly because the two coatings showed comparable proportions of small DAPI-positive objects in the three-dimensional analysis. The tantalum-containing coating may therefore contribute additional surface-specific properties. Previous comparative studies have demonstrated that bacterial adhesion can differ substantially among metallic implant materials. Schildhauer et al., for example, reported significantly lower S. aureus adhesion to pure tantalum than to Ti6Al4V, whereas bacterial adhesion was not significantly correlated with surface roughness across the materials tested [22]. Although these findings cannot be directly extrapolated to a TaCu coating under an established in vivo infection, they support the possibility that coating chemistry itself, rather than Cu availability or surface topography alone, may contribute to bacteria–implant interactions.
Importantly, implant retention in an infected environment represents an integrated outcome that may reflect not only bacterial colonization but also preservation of peri-implant bone and soft tissues, inflammatory responses, and integrity of the implant–bone interface. Thus, the greater retention of TaCu-coated implants despite a confocal profile comparable to that of NbCu may indicate biological effects that are not captured by surface-associated DAPI-positive object analysis alone. Because inflammatory signaling, quantitative bone–implant contact, and mechanical fixation strength were not directly assessed in the present study, the mechanisms underlying the greater retention of TaCu-coated implants remain to be established.
Three-dimensional object-based analysis provided additional information on DAPI-positive material associated with the implant surfaces. Both Cu-containing coatings showed a lower relative proportion of small DAPI-positive objects than uncoated Ti6Al4V, whereas no significant difference was detected between TaCu and NbCu. This finding indicates coating-associated differences in the relative size distribution of segmented DAPI-positive objects. Although previous studies have demonstrated antibacterial properties of Cu-containing titanium materials [9,10,11,12,17,18], the present morphometric findings cannot be directly attributed to bacterial colonization or interpreted as evidence of reduced bacterial burden because DAPI staining does not distinguish bacterial cells from host-derived material.
In addition to its interaction with DNA, DAPI fluorescence has been used for the detection and quantification of intracellular inorganic polyphosphate in microbial cells [23]. Accordingly, the small DAPI-positive objects detected in the present study cannot be interpreted as direct or species-specific bacterial counts. At the spatial resolution used in this study, individual bacterial cocci could not be reliably distinguished from small host-derived nuclear structures or cellular debris. Therefore, the segmented objects were interpreted exclusively according to their reconstructed morphology and volume, without assigning a specific biological identity. Fluorescent nucleic-acid aptamers, for example, have recently enabled specific detection and quantitative confocal imaging of Pseudomonas aeruginosa within both homogeneous and heterogeneous bacterial populations [24]. Similar bacteria-specific labeling approaches, together with culture-based or molecular quantification, would strengthen identification of surface-associated bacterial populations in future studies.
The robustness of this object-based classification was supported by sensitivity analysis. Recalculation of the animal-level proportion of small DAPI-positive objects using thresholds ranging from 25 to 200 μm³ reproduced the same overall coating-related pattern, with uncoated Ti6Al4V consistently showing the highest median proportion. Thus, the observed group relationship was not dependent on selection of the predefined 100 μm³ threshold. Nevertheless, the sensitivity analysis strengthens the robustness of the size-based classification rather than the biological identity of the segmented objects and therefore does not overcome the inherent lack of bacterial specificity of DAPI staining. Furthermore, the animal-level proportion of small DAPI-positive objects is a relative morphometric measure and does not quantify the absolute abundance of segmented objects or bacterial load.
The additional analysis using a more restrictive threshold of 5 µm³ further supported the presence of coating-associated differences in the relative size distribution of DAPI-positive structures. However, the selection of this smaller threshold does not establish bacterial identity, because objects within this volume range may include bacterial aggregates, fragments of host-cell nuclei, or cellular debris, and individual cocci cannot be reliably identified under the imaging conditions used. Importantly, normalization of segmented object counts to the analyzed confocal imaging volume did not reveal statistically significant differences in total object density or in the densities of objects below 5 and 100 µm³ among coating groups. These findings suggest that the observed coating-associated differences primarily reflect changes in the relative distribution of reconstructed object sizes rather than a demonstrated reduction in absolute object abundance. Moreover, because the imaging volume does not account for differences in the accessible surface area of porous and dense implants, volumetric object density should be interpreted as an imaging-based morphometric measure rather than a direct measure of surface colonization or bacterial burden.
Implant geometry represented an additional factor associated with the distribution of DAPI-positive structures, with porous (“rough”) implants exhibiting a higher relative proportion of small objects than dense (“smooth”) implants. This observation is biologically plausible in the context of previous studies demonstrating differences in staphylococcal colonization between smooth and porous or rough titanium surfaces. Braem et al. demonstrated that staphylococcal biofilm growth on porous titanium coatings was influenced by surface characteristics including roughness and hydrophobicity [7], while Gasik et al. reported lower staphylococcal biofilm formation on flat titanium substrates than on untreated porous titanium coatings [8]. More recently, Liu et al. directly compared rough and smooth titanium surfaces and observed greater S. aureus coverage on rough surfaces at 6, 12, and 24 h [25]. Together, these studies support the concept that implant architecture can substantially modify the interface available for bacterial attachment and retention.
The relationship between surface roughness and bacterial attachment should, however, not be interpreted as a simple linear effect. Surface architecture simultaneously alters available surface area, local topography, wettability, surface energy, and the availability of protected niches for bacterial retention. A systematic review of bacterial adhesion strength on titanium surfaces concluded that surface treatments that reduce areas favorable for bacterial adhesion may influence biofilm formation more strongly than surface roughness alone [26]. Clinical evidence is similarly heterogeneous. A systematic review of early biofilm formation on rough and smooth titanium specimens found no significant difference in three of five included studies, whereas two studies reported greater contamination of rough surfaces, leading the authors to conclude that greater susceptibility of rough surfaces cannot be assumed universally [27]. Surface wettability and surface free energy may further modify bacterial adhesion, as supported by a recent systematic review of titanium surface treatments [28].
These considerations are particularly relevant to the present study because the porous (“rough”) implants were not simply dense implants with a higher numerical roughness value; they represented a three-dimensional porous architecture with a substantially different available interface. The higher proportion of small DAPI-positive objects observed on porous implants may be associated with differences in accessible surface area, topographical complexity, and the retention of biological material within the porous architecture, rather than surface roughness alone. The geometry-associated difference observed in the statistical analysis further suggests that coating chemistry and implant architecture may represent distinct contributors to the implant-associated biological environment. From an implant-design perspective, this illustrates an important challenge of additively manufactured porous structures: architectural features intended to increase the interface available for bone integration may simultaneously provide additional opportunities for bacterial attachment and biofilm development [2,7,8,24].
Several limitations should be considered when interpreting the present findings. First, DAPI staining is not bacteria-specific; therefore, the small DAPI-positive objects identified by three-dimensional segmentation cannot be regarded as direct bacterial counts. Their classification was based on reconstructed volume and morphology, and although the stability of the classification was examined across multiple volume thresholds, definitive identification of bacterial cells would require complementary microbiological or bacteria-specific imaging approaches. Second, the experimental model employed a deliberately high local S. aureus inoculum applied directly to the implant and surrounding tissues. This provided a stringent infection challenge for comparing implant surfaces but does not reproduce the lower and more variable bacterial exposure that may occur during perioperative contamination. Third, the relatively small number of animals, together with premature mortality, reduced the sample size available for confocal analysis and resulted in unequal group sizes. In addition, radiographic and macroscopic assessments primarily characterized implant retention and infection-associated changes, whereas quantitative histomorphometry, bone–implant contact measurements, and mechanical fixation testing were not performed. Consequently, the greater retention observed for TaCu-coated implants should not be interpreted as direct evidence of improved osseointegration. Finally, follow-up duration varied among animals because of premature mortality and differences in the timing of experimental endpoints; therefore, the present study does not establish whether the observed differences would persist during longer-term bone remodeling. The unequal observation periods also limit direct comparison of implant retention at a common time point, because animals that died early had a shorter period in which displacement could occur.
Despite these limitations, the present study provides an integrated assessment of TaCu- and NbCu-coated Ti6Al4V implants across cellular, ion-release, microscopic, and infection-challenged in vivo endpoints. The findings highlight an important distinction between implant-associated morphometric characteristics and functional implant retention. Both Cu-containing coatings were associated with a lower relative representation of small DAPI-positive objects than uncoated Ti6Al4V, yet this microscopic endpoint did not differentiate TaCu from NbCu. In contrast, TaCu-coated implants showed the greatest preservation of implant retention under the S. aureus challenge. These observations emphasize that the morphometric characteristics of DAPI-positive structures cannot be used as a surrogate for bacterial burden or implant retention.

5. Conclusions

Magnetron-sputtered TaCu and NbCu coatings on Ti6Al4V implants combined measurable Cu release with no detectable adverse effect on MSC metabolic activity under the tested in vitro conditions. In the experimental S. aureus challenge model, neither coating completely prevented infection; however, TaCu-coated implants showed the greatest preservation of implant retention. Three-dimensional confocal analysis revealed coating- and geometry-associated differences in the relative size distribution of DAPI-positive objects, including at a more restrictive threshold of 5 µm³. However, no statistically significant differences in absolute volumetric object density were detected among coating groups. These findings describe morphometric characteristics of implant-associated biological material rather than direct measurements of bacterial burden. These findings identify implant retention as the principal functional outcome of the present study and support further investigation of TaCu coatings using complementary microbiological, histological, and mechanical assessments.

Author Contributions

Conceptualization, B.A. and D.A.; methodology, A.K., B.A., D.A., B.M., A.N., D.S. and A.B.; software, B.M. and Y.S; validation, S.A..; formal analysis, Y.S.; investigation, A.K., A.N., D.S., A.B. and Y.S.; resources, B.A., D.A. and B.M.; data curation, A.K., B.M., A.N., S.A. and Y.S.; writing—original draft preparation, A.K. and Y.S.; writing—review and editing, D.A., S.A. and Y.S.; visualization, A.K.; supervision, D.S.; project administration, B.A.; funding acquisition, B.A. All authors have read and agreed to the published version of the manuscript.

Funding

This research is funded by the Ministry of Science and Higher Education of the Republic of Kazakhstan (Grant No. BR24992786).

Institutional Review Board Statement

All animal experiments were conducted only after approval by the Local Ethics Committee of the National Scientific Center of Traumatology and Orthopedics named after Academician N.D. Batpenov, approval No. 1 dated March 28, 2022

Data Availability Statement

The data presented in this study are available on request from the corresponding author.

Acknowledgments

The author acknowledges the Nazarbayev University Research Core Facilities for providing access to the confocal microscopy and technical support.

Conflicts of Interest

The authors declare no conflicts of interest.

Abbreviations

The following abbreviations are used in this manuscript:
ANOVA Analysis of variance
CCK-8 Cell Counting Kit-8
CFU Colony-forming units
Cu Copper
DAPI 4′,6-Diamidino-2-phenylindole
EDX Energy-dispersive X-ray spectroscopy
ICP-MS Inductively coupled plasma mass spectrometry
MSCs Mesenchymal stromal cells
Nb Niobium
NbCu Niobium–copper coating
PVD Physical vapor deposition
SD Standard deviation
SEM Scanning electron microscopy
Ta Tantalum
TaCu Tantalum–copper coating
Ti6Al4V Titanium–6 aluminum–4 vanadium alloy

Appendix A

Appendix A.1

Figure A1. Sensitivity analysis of the volume threshold used to classify small DAPI-positive objects. The proportion of small DAPI-positive objects was recalculated independently for each animal using volume thresholds of 25, 50, 75, 100, 125, 150, and 200 μm³. Lines represent the median animal-level proportion for NbCu-coated, TaCu-coated, and uncoated Ti6Al4V implants at each threshold. The overall group pattern remained consistent across the evaluated threshold range.
Figure A1. Sensitivity analysis of the volume threshold used to classify small DAPI-positive objects. The proportion of small DAPI-positive objects was recalculated independently for each animal using volume thresholds of 25, 50, 75, 100, 125, 150, and 200 μm³. Lines represent the median animal-level proportion for NbCu-coated, TaCu-coated, and uncoated Ti6Al4V implants at each threshold. The overall group pattern remained consistent across the evaluated threshold range.
Preprints 242181 g0a1

References

  1. Izakovicova, P.; Borens, O.; Trampuz, A. Periprosthetic joint infection: Current concepts and outlook. EFORT Open Rev. 2019, 4, 482–494. [Google Scholar] [CrossRef] [PubMed]
  2. Klouche, S.; Sariali, E.; Mamoudy, P. Total hip arthroplasty revision due to infection: A cost analysis approach. Orthop. Traumatol. Surg. Res. 2010, 96, 124–132. [Google Scholar] [CrossRef]
  3. Arciola, C.R.; Campoccia, D.; Montanaro, L. Implant infections: Adhesion, biofilm formation and immune evasion. Nat. Rev. Microbiol. 2018, 16, 397–409. [Google Scholar] [CrossRef] [PubMed]
  4. Arciola, C.R.; Campoccia, D.; Speziale, P.; Montanaro, L.; Costerton, J.W. Biofilm formation in Staphylococcus implant infections. A review of molecular mechanisms and implications for biofilm-resistant materials. Biomaterials 2012, 33, 5967–5982. [Google Scholar] [CrossRef] [PubMed]
  5. Calazans Neto, J.V.; Valente, M.L.C.; Dos Reis, A.C. Effect of pores on cell adhesion to additively manufactured titanium implants: A systematic review. J. Prosthet. Dent. 2025, 133, 990–997. [Google Scholar] [CrossRef] [PubMed]
  6. Cleemput, S.; Huys, S.E.F.; Cleymaet, R.; Cools, W.; Mommaerts, M.Y. Additively manufactured titanium scaffolds and osteointegration—Meta-analyses and moderator-analyses of in vivo biomechanical testing. Biomater. Res. 2021, 25, 18. [Google Scholar] [CrossRef] [PubMed]
  7. Braem, A.; Van Mellaert, L.; Mattheys, T.; et al. Staphylococcal biofilm growth on smooth and porous titanium coatings for biomedical applications. J. Biomed. Mater. Res. A 2014, 102, 215–224. [Google Scholar] [CrossRef] [PubMed]
  8. Gasik, M.; Van Mellaert, L.; Pierron, D.; et al. Reduction of biofilm infection risks and promotion of osteointegration for optimized surfaces of titanium implants. Adv. Healthc. Mater. 2012. [Google Scholar] [CrossRef] [PubMed]
  9. Jacobs, A.; Renaudin, G.; Forestier, C.; Nedelec, J.M.; Descamps, S. Biological properties of copper-doped biomaterials for orthopedic applications: A review of antibacterial, angiogenic and osteogenic aspects. Acta Biomater. 2020. [Google Scholar] [CrossRef] [PubMed]
  10. Mahmoudi, P.; Akbarpour, M.R.; Babaei Lakeh, H.; et al. Antibacterial Ti-Cu implants: A critical review on mechanisms of action. Mater. Today Bio 2022, 17, 100447. [Google Scholar] [CrossRef] [PubMed]
  11. Zhang, E.; Li, F.; Wang, H.; et al. Toward a molecular understanding of the antibacterial mechanism of copper-bearing titanium alloys against Staphylococcus aureus. Adv. Healthc. Mater. 2016. [Google Scholar] [CrossRef] [PubMed]
  12. Liu, J.; Zhang, X.; Wang, H.; et al. The antibacterial properties and biocompatibility of a Ti-Cu sintered alloy for biomedical application. Biomed. Mater. 2014, 9, 025013. [Google Scholar] [CrossRef] [PubMed]
  13. Wang, X.; et al. Tantalum and its derivatives in orthopedic and dental implants: Osteogenesis and antibacterial properties. Colloids Surf. B Biointerfaces 2021, 208, 112055. [Google Scholar] [CrossRef] [PubMed]
  14. Bai, Y.; et al. Characterization, corrosion behavior, cellular response and in vivo bone tissue compatibility of titanium-niobium alloy with low Young’s modulus. Mater. Sci. Eng. C 2016. [Google Scholar] [CrossRef] [PubMed]
  15. Azamatov, B.; Alontseva, D.; Borisov, A.; Maratuly, B.; Dogadkin, D.; Safarova, Y.; Yamanoglu, R. Magnetron sputtering of antibacterial and antifungal tantalum-copper and niobium-copper coatings on three dimensional-printed porous titanium alloy scaffolds: Part I. Johns. Matthey Technol. Rev. 2025, 69, 76–87. [Google Scholar] [CrossRef]
  16. Azamatov, B.; Borisov, A.; Maratuly, B.; Dogadkin, D.; Safarova, Y.; Yamanoglu, R.; Alontseva, D. Magnetron sputtering of antibacterial and antifungal tantalum-copper and niobium-copper coatings on three dimensional-printed porous titanium alloy scaffolds: Part II. Johns. Matthey Technol. Rev. 2025, 69, 88–98. [Google Scholar] [CrossRef]
  17. Azamatov, B.; Dzhes, A.; Borisov, A.; Kaliyev, D.; Maratuly, B.; Sagidugumar, A.; et al. Antibacterial properties of copper-tantalum thin films: The impact of copper content and thermal treatment on implant coatings. Heliyon 2025, 11, e41130. [Google Scholar] [CrossRef] [PubMed]
  18. Kassymbayev, A.; Pogrebnjak, A.; Kimossov, R.; Myakinin, A.; Borisov, A.; Azamatov, B.; Talipova, A.; Savitskaya, I.; Shokatayeva, D.; Zholshybek, N.; Sahul, M.; Adamiak, S.; Bobitski, Y.; Webster, R.F.; Maksakova, O.; Turlybekuly, A. Structure, mechanical performance and antibacterial behavior of TaCuN coatings deposited by reactive magnetron co-sputtering. Surf. Coat. Technol. 2026, 530, 133529. [Google Scholar] [CrossRef]
  19. Hoene, A.; Prinz, C.; Walschus, U.; Lucke, S.; Patrzyk, M.; Wilhelm, L.; Neumann, H.G.; Schlosser, M. In vivo evaluation of copper release and acute local tissue reactions after implantation of copper-coated titanium implants in rats. Biomed. Mater. 2013, 8, 035009. [Google Scholar] [CrossRef] [PubMed]
  20. Alontseva, D.; Azamatov, B.; Borisov, A.; Maratuly, B.; Safarova (Yantsen), Y.; Voinarovych, S.; Dzhes, A.; Łatka, L. Antibacterial Ti-Cu and Ta-Cu Coatings for Endoprostheses Applied by Magnetron Sputtering onto Ti6Al4V Alloy. Adv. Mater. Sci. 2024, 24, 23–41. [Google Scholar] [CrossRef]
  21. Zhuang, Y.; Ren, L.; Zhang, S.; Wei, X.; Yang, K.; Dai, K. Antibacterial effect of a copper-containing titanium alloy against implant-associated infection induced by methicillin-resistant Staphylococcus aureus. Acta Biomater. 2021, 119, 472–484. [Google Scholar] [CrossRef] [PubMed]
  22. Schildhauer, T.A.; Robie, B.; Muhr, G.; Köller, M. Bacterial adherence to tantalum versus commonly used orthopedic metallic implant materials. J. Orthop. Trauma 2006, 20, 476–484. [Google Scholar] [CrossRef] [PubMed]
  23. Kulakova, A.N.; Hobbs, D.; Smithen, M.; Pavlov, E.; Gilbert, J.A.; Quinn, J.P.; McGrath, J.W. Direct quantification of inorganic polyphosphate in microbial cells using 4′,6-diamidino-2-phenylindole (DAPI). Environ. Sci. Technol. 2011, 45, 7799–7803. [Google Scholar] [CrossRef] [PubMed]
  24. Mezouarhi, C.; Vauchelles, R.; Abdallah, B.; Janel, R.; Ouadghiri, M.; Ait Benhassou, H.; Pelet, S.; Fechter, P.; Choulier, L. Bioimaging with fluorescent nucleic-acid aptamers for the specific detection and quantification of Pseudomonas aeruginosa alone and in heterogeneous bacterial populations. MicrobiologyOpen 2025, 14, e70202. [Google Scholar] [CrossRef] [PubMed]
  25. Liu, J.; Daher, M.; Gilreath, N.; Barrett, C.; Cohen, E.; Antoci, V., Jr. A comparison of in-vitro Staphylococcus aureus growth on rough and smooth titanium surfaces. Hip Pelvis 2025, 37, 197–204. [Google Scholar] [CrossRef] [PubMed]
  26. Tardelli, J.D.C.; Bagnato, V.S.; Dos Reis, A.C. Bacterial adhesion strength on titanium surfaces quantified by atomic force microscopy: A systematic review. Antibiotics 2023, 12, 994. [Google Scholar] [CrossRef] [PubMed]
  27. Brum, R.S.; Apaza-Bedoya, K.; Labes, L.G.; Volpato, C.A.M.; Pimenta, A.L.; Benfatti, C.A.M. Early biofilm formation on rough and smooth titanium specimens: A systematic review of clinical studies. J. Oral Maxillofac. Res. 2021, 12, e1. [Google Scholar] [CrossRef] [PubMed]
  28. Soares, V.D.M.; Reis, A.C.D.; Valente, M.L.D.C. Effect of surface treatment on titanium surface free energy and its relation to bacterial activity: A systematic review. Eur. J. Prosthodont. Restor. Dent. 2024, 32, 314–325. [Google Scholar] [CrossRef] [PubMed]
  29. Jaksa, L.; Azamatov, B.; Nazenova, G.; Alontseva, D.; Haidegger, T. State of the Art in Medical Additive Manufacturing. Acta Polytech. Hung. 2024, 21, 553–576. [Google Scholar] [CrossRef]
Figure 1. Experimental design of the in vivo S.aureus infection model.
Figure 1. Experimental design of the in vivo S.aureus infection model.
Preprints 242181 g001
Figure 2. Surface morphology, in vitro biocompatibilty and copper release from coated and uncoated Ti6Al4V implants. (a) Representative scanning electron microscopy (SEM) images showing the surface morphology of the investigated TaCu- and NbCu-coated porous Ti6Al4V implants at different magnifications; (b)Metabolic activity of rat MSCs following 24 h exposure to implant-conditioned media, determined using the CCK-8 assay; (c) Cu concentrations measured in the immersion medium of TaCu- and NbCu-coated Ti6Al4V implants with porous (rough) and dense (smooth) geometries over 10 days by ICP-MS. Data are presented as mean ± SD from three independent experiments (n = 3), each performed in technical triplicate.
Figure 2. Surface morphology, in vitro biocompatibilty and copper release from coated and uncoated Ti6Al4V implants. (a) Representative scanning electron microscopy (SEM) images showing the surface morphology of the investigated TaCu- and NbCu-coated porous Ti6Al4V implants at different magnifications; (b)Metabolic activity of rat MSCs following 24 h exposure to implant-conditioned media, determined using the CCK-8 assay; (c) Cu concentrations measured in the immersion medium of TaCu- and NbCu-coated Ti6Al4V implants with porous (rough) and dense (smooth) geometries over 10 days by ICP-MS. Data are presented as mean ± SD from three independent experiments (n = 3), each performed in technical triplicate.
Preprints 242181 g002
Figure 3. Radiographic assessment of implant retention following experimental Staphylococcus aureus challenge. (a–f) Representative radiographs of NbCu-coated, TaCu-coated, and uncoated Ti6Al4V implants with smooth and rough geometries. Retained implants remained localized within the distal femoral implantation site, whereas displaced implants had migrated from the original implantation site. (g) Radiographic implant retention according to coating type. Implant retention was observed in 8/8 (100%) TaCu, 4/8 (50%) NbCu, and 0/8 (0%) uncoated Ti6Al4V implants. The overall association between coating type and implant retention was significant (Fisher–Freeman–Halton exact test, p = 0.00016). Pairwise Fisher’s exact tests with Holm correction showed a significant difference between TaCu and uncoated Ti6Al4V (adjusted p = 0.00047).
Figure 3. Radiographic assessment of implant retention following experimental Staphylococcus aureus challenge. (a–f) Representative radiographs of NbCu-coated, TaCu-coated, and uncoated Ti6Al4V implants with smooth and rough geometries. Retained implants remained localized within the distal femoral implantation site, whereas displaced implants had migrated from the original implantation site. (g) Radiographic implant retention according to coating type. Implant retention was observed in 8/8 (100%) TaCu, 4/8 (50%) NbCu, and 0/8 (0%) uncoated Ti6Al4V implants. The overall association between coating type and implant retention was significant (Fisher–Freeman–Halton exact test, p = 0.00016). Pairwise Fisher’s exact tests with Holm correction showed a significant difference between TaCu and uncoated Ti6Al4V (adjusted p = 0.00047).
Preprints 242181 g003
Figure 4. Three-dimensional object-based analysis of implant-associated DAPI-positive structures. (a) Representative three-dimensional reconstruction of DAPI-positive structures associated with the implant surface. (b) Corresponding Imaris object-based segmentation used for volumetric classification. Segmented objects were classified according to reconstructed volume using a predefined threshold of 100 μm³ as small (<100 μm³) or large (≥100 μm³) DAPI-positive objects. (c) Animal-level proportion of small DAPI-positive objects according to implant coating. Uncoated Ti6Al4V implants exhibited a higher proportion of small objects than NbCu- and TaCu-coated implants (Holm-adjusted p = 0.00012 and p < 0.0001, respectively), whereas NbCu and TaCu did not differ significantly (adjusted p = 0.731). (d) Animal-level proportion of small DAPI-positive objects according to implant geometry; rough implants exhibited a higher proportion than smooth implants (p < 0.001). Each point represents one animal, and horizontal lines indicate the median and interquartile range. Statistical comparisons were based on beta regression accounting for coating and implant geometry, with Holm adjustment for pairwise comparisons where applicable. Because DAPI staining is not bacteria-specific, object classification reflects reconstructed size and morphology and does not constitute definitive identification of bacterial or mammalian cells; (e) Animal-level proportion of DAPI-positive objects smaller than 5 µm³ according to implant coating. The overall difference among groups was significant (Kruskal–Wallis test, p = 0.0156), with higher proportions in uncoated Ti6Al4V implants than in NbCu- and TaCu-coated implants (Holm-adjusted p = 0.038 for both comparisons); (f) Total volumetric density of segmented DAPI-positive objects according to implant coating, expressed as objects/mm³. No significant differences were detected among coating groups (Kruskal–Wallis test, p = 0.769). Each point represents one animal. Statistical comparisons for panels (e) and (f) were based on nonparametric tests.
Figure 4. Three-dimensional object-based analysis of implant-associated DAPI-positive structures. (a) Representative three-dimensional reconstruction of DAPI-positive structures associated with the implant surface. (b) Corresponding Imaris object-based segmentation used for volumetric classification. Segmented objects were classified according to reconstructed volume using a predefined threshold of 100 μm³ as small (<100 μm³) or large (≥100 μm³) DAPI-positive objects. (c) Animal-level proportion of small DAPI-positive objects according to implant coating. Uncoated Ti6Al4V implants exhibited a higher proportion of small objects than NbCu- and TaCu-coated implants (Holm-adjusted p = 0.00012 and p < 0.0001, respectively), whereas NbCu and TaCu did not differ significantly (adjusted p = 0.731). (d) Animal-level proportion of small DAPI-positive objects according to implant geometry; rough implants exhibited a higher proportion than smooth implants (p < 0.001). Each point represents one animal, and horizontal lines indicate the median and interquartile range. Statistical comparisons were based on beta regression accounting for coating and implant geometry, with Holm adjustment for pairwise comparisons where applicable. Because DAPI staining is not bacteria-specific, object classification reflects reconstructed size and morphology and does not constitute definitive identification of bacterial or mammalian cells; (e) Animal-level proportion of DAPI-positive objects smaller than 5 µm³ according to implant coating. The overall difference among groups was significant (Kruskal–Wallis test, p = 0.0156), with higher proportions in uncoated Ti6Al4V implants than in NbCu- and TaCu-coated implants (Holm-adjusted p = 0.038 for both comparisons); (f) Total volumetric density of segmented DAPI-positive objects according to implant coating, expressed as objects/mm³. No significant differences were detected among coating groups (Kruskal–Wallis test, p = 0.769). Each point represents one animal. Statistical comparisons for panels (e) and (f) were based on nonparametric tests.
Preprints 242181 g004
Table 1. Magnetron sputtering parameters used for the deposition of NbCu and TaCu coatings on Ti6Al4V implants.
Table 1. Magnetron sputtering parameters used for the deposition of NbCu and TaCu coatings on Ti6Al4V implants.
Coating Composition
and Group
Sputtering material Parameters/settings
Current
I(A)
Voltage
U (V)
Deposition time, t (min) Sputtering distance, H
(mm)
Plasma gas (Ar) flow rate, slpm
Nb-Cu
Nb 3.0 283 90
210 0.062
Cu 1.0 339
Ta-Cu
Ta 3.0 319
Cu 0.99 371
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.