Submitted:
02 November 2026
Posted:
04 November 2026
You are already at the latest version
Abstract
For a complete blackbody source in a cooler environment, the fraction of thermal radiation’s energy convertible to work is given by the Petela factor. A converter that absorbs only part of the incident spectrum should be measured not against this full-spectrum factor but against the exergy fraction of the radiation it actually absorbs. Under a linear allocation of incident energy and exergy at each frequency, the difference between these two fractions is an energy-weighted covariance between the absorptance and the per-frequency exergy fraction, divided by the mean absorptance. For a three-region absorber that absorbs a fraction of radiation below a threshold frequency, all radiation in a finite band above the threshold, and none beyond, the covariance is affine in the sub-gap absorption fraction. A closed-form threshold determines the sign of the benchmark difference. For every absorption profile with positive absorbed energy, this difference lies between two sharp bounds depending only on the source and environment temperatures. Whether real converters realize the linear-allocation assumption, and how to classify the sign otherwise, remain open.
Keywords:
thermal radiation
; exergy
; spectral selectivity
; thermophotovoltaics
; second-law efficiency
; linear allocation
1. Introduction
The exergy fraction of thermal radiation is the fraction of its energy convertible to work. For a complete blackbody source at temperature T in an environment at temperature , this fraction has a known closed form, the Petela factor with [1]. The second-law efficiency of a radiative converter is conventionally defined as its first-law efficiency divided by [2,3]. For the comparison here, first-law efficiency means work output divided by allocated absorbed radiation energy. The work output and this energy input are held fixed when comparing the two exergy factors. Real converters absorb only part of the incident spectrum, and need not equal the exergy fraction of what they actually absorb. Prior work has expressed as the Planck-weighted integral of a per-frequency exergy fraction [4], extended the exergy formalism to diluted thermal radiation [5], and formulated it for arbitrary source spectra [6]. None of these treatments determines the sign or magnitude of the difference between and the correct absorbed-spectrum benchmark for a fixed absorption profile, or supplies a closed threshold that identifies its sign for a finite-band profile. A sign criterion would avoid repeating spectral integrations as the sub-gap absorptance varies, while keeping the temperature ratio and absorbing band fixed.
This paper closes that gap under a linear allocation assumption. At each frequency, the fraction of incident exergy absorbed is taken to equal the fraction of incident energy absorbed, and this common fraction is denoted . Under this allocation, the exergy fraction of the absorbed spectrum minus equals the incident-energy-weighted covariance between and the per-frequency exergy fraction, divided by the mean absorptance (Equation 4). For a three-region profile that absorbs a fraction a below a threshold frequency, all radiation across a finite band immediately above the threshold, and none beyond, this covariance is affine in a, and its unique zero is a closed-form threshold that decides whether exceeds, equals, or falls short of the absorbed-spectrum benchmark (Theorem 1). For every absorption profile with positive absorbed energy, the correction under this allocation is bracketed by two sharp bounds that depend only on T and (Proposition 1). An ideal step that rejects all radiation below a bandgap and absorbs everything above it, evaluated at four temperature–bandgap pairs from two published sources, gives an absorbed-spectrum benchmark exceeding by 2.37–5.28% (Table 1). These are evaluations of the model at the tabulated pairs, not corrections reconstructed from measured device spectra. The binary step contains no fractional absorption; results for profiles that partially absorb a frequency remain conditional on linear allocation, and identifying either kind of profile with a physical device still requires an appropriate source spectrum and system boundary.
2. Covariance Identity
Let T be the source temperature and the environment temperature, and the temperature ratio. For angular frequency , the dimensionless frequency is the photon energy in units of the thermal scale , with ℏ and the reduced Planck and Boltzmann constants. In this variable, the incident blackbody spectral energy density is Planck’s , with the Bose–Einstein distribution. Its overall physical prefactor cancels in every ratio below and is dropped. At each frequency x, the exergy-to-energy ratio of the same radiation against the environment at (Equation (11) [4]) is
The ratio f is strictly increasing on , with limits
The Petela factor is the average of f over the blackbody spectrum weighted by w. It was first derived from a piston-cylinder argument [1] and later evaluated in closed form as a Planck-weighted integral [4].
A real converter absorbs only a subspectrum. Its per-frequency absorption fraction is represented by an admissible absorptance, a measurable function with so that the denominator below is positive. Under linear allocation, is simultaneously the incident-energy and incident-exergy fraction at each frequency, and the absorbed-spectrum benchmark is
This specifies the input allocation, not a physical attenuation law for . For functions such that , , and are w-integrable, the w-weighted mean and covariance are
Then and , and subtracting gives
Section 3 evaluates on a three-region absorption profile, giving a closed-form threshold for the sign of .
3. Finite-Band Classification
Let be the gap frequency at which the absorbing band starts and its bandwidth. A finite-band absorber captures every photon in the band , absorbs a fraction of photons in the sub-gap , and transmits everything above the band. The above-gap region contains G together with the transmitted tail. The absorptance is
The total spectral w-mass is . By the covariance identity of Section 2, the Petela error’s sign is that of ; for the finite-band family, this covariance involves two derived quantities. The first, P, is the excess of the fully absorbed band’s mean exergy over , weighted by the band’s w-mass. The second, Q, is the mass-weighted separation between the sub-gap and the above-gap region; it is positive by strict increase of f. Explicitly,
For fixed r, , and , the coefficients P and Q are independent of a. Their spectral integrals can be evaluated once and reused as a varies.
Theorem 1
(Finite-band branch classification). The covariance is affine and strictly decreasing in a, with unique zero at . The Petela error is positive when , zero when , and negative when . Equality within the finite-band family is attained if and only if , at .
Proof.
Since B and A partition the spectrum, , where . Substituting into and collecting powers of a gives
This covariance is affine and, since , strictly decreasing in a. The denominator is positive since , so the covariance identity of Section 2 gives . Since both Q and the denominator are positive, this has the sign of . □
Corollary 1
(). For every , ; equivalently, whenever .
Proof.
At , the absorptance is , so . By strict increase of f, every f-value on the excluded tail exceeds every f-value on the retained region . Enlarging the averaging domain to the full support therefore strictly raises the mean, giving . □
4. Universal Bounds
Strict monotonicity of f gave Corollary 1’s bound at ; the same fact yields bounds on valid for every admissible .
Proposition 1
(Sharp universal bounds). For and every admissible absorptance α, the Petela benchmark satisfies
The two bounds are the infimum and supremum of over admissible α, and neither is attained.
Proof.
By Equation 2, and . Since f is strictly increasing on the open interval , these limits are the unattained infimum and supremum of f, so for every . The Petela benchmark is a weighted mean of these values with positive total w-mass and therefore lies strictly in the same interval. For sharpness, the characteristic functions and are admissible for every since is positive and finite, and their Petela benchmarks satisfy
□
Theorem 1 classifies the parametric family . A support condition can also establish the positive branch for more general absorptances.
Lemma 1
(Positive branch criterion). Let and let α be admissible with support in . If , then .
Proof.
Support in and Lebesgue-nullity of reduce to , which admissibility makes positive and finite. Admissibility also gives , and strict monotonicity of f gives on , so . Dividing by gives . □
The four model evaluations in Table 1 use the ideal above-gap step , with . At each tabulated temperature–bandgap pair, , so Lemma 1 places every row in the branch. The last column quantifies the resulting overstatement of second-law efficiency.
The four rows are numerical consequences of Lemma 1, not new measurements. The LM-InGaAs row at 1480 K, the lowest source temperature in the table, shows the largest correction of 5.28%. At a fixed bandgap, lower source temperatures place a larger fraction of the full-spectrum weight below the bandgap, where the ideal step discards it.
5. Discussion
The finite-band covariance formula and threshold were checked numerically on a 45-member double-precision grid.1 The grid spans K, , , and K. At each grid member, six sub-gap absorptances give 270 covariance comparisons. The affine formula agrees with an independently evaluated covariance with worst absolute discrepancy . The full-spectrum mean matches the Petela factor at the three temperatures, and 15 numerically resolvable interior thresholds agree with bisection with worst absolute discrepancy . In a separate 21-point sweep of , 75 of 945 sampled covariance magnitudes are at most and are reported as numerically unresolved.
Prior treatments do not compute the sign or magnitude of the correction under a fixed absorption profile. The framework was set up in stages: the whole-spectrum reference [1], the per-mode quality factor and its Planck-weighted mean [4], diluted radiation and its nonlinear entropy correction [5], and the exergy flux of arbitrary spectra [6]. These treatments work with entropy conventions on arbitrary spectra, not with a fixed finite-band absorber. Later applied work uses different objects: band-limited radiation integrals [7], incident-normalised work-efficiency factors that replace [8,9], Carnot-based efficiencies for selective coatings [10], and equivalent-temperature approximations for non-blackbody radiation [11]. The closed sub-gap threshold in Theorem 1 does not appear in these treatments.
The finite-band classification is conditional on the linear-allocation convention of Equation 3. A physical absorber that attenuates an occupation number is not generally linear in that attenuation factor for entropy, and non-blackbody radiation conversion has been argued to be inherently irreversible [6]. The theorem also does not cover angular or polarization correlations or frequency-dependent reflection coupled to re-emission. These require a separate entropy and boundary model. An admissible measured absorptance outside the finite-band family remains covered by the covariance identity and universal bounds under the stated allocation, but not by Theorem 1.
When first-law efficiency is normalized to allocated absorbed energy, the corresponding second-law efficiency uses rather than under the stated allocation. On the four rows of Table 1, exceeds by 2.37–5.28%, so a reported second-law efficiency computed against overstates the corrected value by the same amount. The correction does not certify the physical allocation, and it does not replace device-level accounting of reflected, re-emitted, or parasitic fluxes.
6. Conclusions
Under linear incident-energy allocation, the exergy factor for converting an absorbed-energy-normalized first-law efficiency to second-law efficiency is , a weighted mean of the per-mode quality factor over the absorbed spectrum. It differs from the full-spectrum Petela factor by an energy-weighted covariance divided by the mean absorptance. The covariance’s sign is decidable in closed form for the finite-band family. A single closed threshold in the sub-gap absorptance selects the positive, zero, or negative branch. For every admissible absorptance, lies strictly in the open interval , and both endpoints are unattained. On four thermophotovoltaic model rows, the correction is 2.37–5.28%. Whether a real selective absorber realises linear allocation is a physical question outside the scope of this paper. Extending the sign classification to profiles that attenuate an occupation number requires an additional entropy model.
Funding
This research received no external funding.
Data Availability Statement
This analytical and numerical study did not require ethical approval or participant consent. The numerical verification code and fixed model parameters are available at https://github.com/ChakshuGupta13/lab/tree/main/energy/gupta2026exergy.
Acknowledgments
GitHub Copilot was used to assist with manuscript drafting and editing and preparation of the numerical verification code. The author takes responsibility for all content.
Conflicts of Interest
The author declares no conflicts of interest.
References
- Petela, R. Exergy of Heat Radiation. J. Heat Transf. 1964, 86, 187–192. [Google Scholar] [CrossRef]
- LaPotin, A.; Schulte, K.L.; Steiner, M.A.; Buznitsky, K.; Kelsall, C.C.; Friedman, D.J.; Tervo, E.J.; France, R.M.; Young, M.R.; Rohskopf, A.; et al. Thermophotovoltaic efficiency of 40%. Nature 2022, 604, 287–291. [Google Scholar] [CrossRef] [PubMed]
- Burger, T.; Sempere, C.; Roy-Layinde, B.; Lenert, A. Present Efficiencies and Future Opportunities in Thermophotovoltaics. Joule 2020, 4, 1660–1680. [Google Scholar] [CrossRef]
- Karlsson, S. The Exergy of Incoherent Electromagnetic Radiation. Physica Scr. 1982, 26, 329–332. [Google Scholar] [CrossRef]
- Landsberg, P.T.; Tonge, G. Thermodynamics of the conversion of diluted radiation. J. Phys. A Math. General. 1979, 12, 551. [Google Scholar] [CrossRef]
- Wright, S.E.; Rosen, M.A.; Scott, D.S.; Haddow, J.B. The exergy flux of radiative heat transfer with an arbitrary spectrum. Exergy An. Int. J. 2002, 2, 69–77. [Google Scholar] [CrossRef]
- Badescu, V. Unified upper bound for photothermal and photovoltaic conversion efficiency. J. Appl. Phys. 2008, 103, 054903. [Google Scholar] [CrossRef]
- Badescu, V. Upper bound efficiency for several configurations of work extractors receiving and releasing statistically deformed heat and radiation fluxes. Physica Scr. 2022, 97, 030002. [Google Scholar] [CrossRef]
- Badescu, V. Upper bound efficiency for thermal radiation energy conversion by using spectrally selective electrical, chemical and mechanical work extractors. Physica Scr. 2023, 98, 065021. [Google Scholar] [CrossRef]
- Hu, P.; Liu, Y.; Zhang, Q.; Chen, Z. Thermodynamic analysis on medium-high temperature solar thermal systems with selective coatings. Sci. China Technol. Sci. 2013, 56, 3137–3143. [Google Scholar] [CrossRef]
- Shan, S.; Cheng, Z. Non-blackbody radiation exergy analysis model based on equivalent temperature method for energy conversion application. Energy 2026, 348, 140494. [Google Scholar] [CrossRef]
Table 1.
Full-spectrum Petela factor versus the absorbed-spectrum benchmark under the ideal above-gap step at K. The last column is , the percent overstatement of second-law efficiency over for a common first-law efficiency normalized to allocated absorbed energy.
Table 1.
Full-spectrum Petela factor versus the absorbed-spectrum benchmark under the ideal above-gap step at K. The last column is , the percent overstatement of second-law efficiency over for a common first-law efficiency normalized to allocated absorbed energy.
| row | T (K) | (eV) | overstatement | ||
|---|---|---|---|---|---|
| 1.4/1.2 eV tandem [2] | 2673 | 1.20 | 0.8513 | 0.8715 | 2.37% |
| 1.2/1.0 eV tandem [2] | 2400 | 1.00 | 0.8344 | 0.8558 | 2.56% |
| LM-InGaAs [3] | 1480 | 0.75 | 0.7319 | 0.7706 | 5.28% |
| Si [3] | 2300 | 1.12 | 0.8273 | 0.8518 | 2.97% |
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
Copyright: This open access article is published under a Creative Commons CC BY 4.0 license, which permit the free download, distribution, and reuse, provided that the author and preprint are cited in any reuse.