Preprint
Article

This version is not peer-reviewed.

Flow Regime Map and Gravity Suppression Mechanism of a Top-Heated Pulsating Heat Pipe for Battery Thermal Management

Submitted:

26 October 2026

Posted:

27 October 2026

You are already at the latest version

Abstract
Pulsating heat pipes (PHPs) beneath a battery cold plate operate with the evaporator above the condenser, so that vapour expands directly against gravity. This orientation is imposed by vehicle packaging, yet its internal flow has rarely been resolved. A closed-loop borosilicate glass PHP of 2 mm/3 mm bore charged with methanol was visualized at 960 frames per second at 17, 22 and 27 W and charged volume fractions of 8.5, 17.0 and 25.6 %, and modelled with a one-dimensional force balance. Eleven flow regimes are grouped into three families-evaporation froth (A), oscillation confined to the condenser and adiabatic sections (B) and turn-to-turn migration (C)-and mapped in the power/filling-ratio plane. Vapour pressure dominates the force balance at 0.12 N, twice the wall friction, while gravity contributes less than 5 %. The model reproduces the measured plug amplitude to within 0.013 m at low filling ratio. Thermal resistance rises from 1.13-1.43 K/W at 8.5 % to 2.11-3.85 K/W at 25.6 %, so underfilling is favourable here. The map allows dry-out and flooding to be diagnosed from the observed regime in gravity-suppressed PHP battery modules.
Keywords: 
;  ;  ;  ;  ;  

1. Introduction

A traction battery releases 50-150 kJ over a 0.2C to 1C discharge, and the heat generation rate of a single cell rises from 13 W at 1C to 91 W at 4C [1]. Keeping the cell below 60 °C therefore requires a spreader of low thermal resistance and small volume. The pulsating heat pipe (PHP), introduced by Akachi [2], meets both requirements: a meandering capillary channel, partially filled with a working fluid, contains a train of liquid plugs and vapour slugs driven by the saturation-pressure difference between the evaporator and the condenser [3]. The plugs oscillate by inertia rather than by capillary pumping [4,5], so that the effective conductivity can exceed that of copper by an order of magnitude [6].
Because the oscillation is driven by a pressure difference, the orientation relative to gravity is a first-order parameter. In the arrangement imposed by a battery pack cooled from below, with the evaporator on top and the condenser at the bottom, vapour generated in the evaporator must expand against gravity to reach the condenser. This arrangement suppresses the oscillation of closed-loop PHPs and raises the flow resistance [7,8], and a dedicated comparison of bottom-heated and top-heated operation has shown that the two configurations do not share a common transition mechanism [1]. Anti-gravity designs have therefore been pursued by reconstructing the channel in three dimensions [9,10], and by direct-contact bottom cooling of lithium-ion cells [11,12], but the internal flow of a conventional planar PHP in this orientation has not been documented at the level of individual plugs.
The literature falls into three strands. The first established the sensitivity of performance to tube diameter, filling ratio and working fluid [13,14,15,16,17], and to the number of turns and their uniformity [18,19,20]. These studies produced correlations and operational limits but treated the device as a black box. The second strand opened the box. Katpradit et al. [21] reported intermittent dry-out in a glass PHP and showed that its duration grows with heating power; Zuo et al. [22,23], Liu et al. [24], Tong et al. [25], Qu et al. [26], Khandekar [27], Borgmeyer and Ma [28] and Chien et al. [29] recorded plug motion, circulation and the onset of dry-out in tubular and flat-plate geometries, while Bhuwakietkumjohn and Rittidech [30], Rittidech and Sangiamsuk [31] and Das et al. [32] extended the observations to check-valve and single-capillary devices. The third strand modelled the plug dynamics: mass-spring-damper analogies [33], start-up asymptotics [34] and one-dimensional marching schemes [35] reproduce the amplitude once the driving force is known, and the force balance itself requires the wall friction, the bend loss and the capillary pressure at the menisci [36,37].
Recent work has continued along the same three strands. Cheng and Wong [38] resolved the start-up of PHPs of different bore, Sun and Jia [39] visualized a flat-plate device with two condensers, Bao et al. [40] mapped the flow of a low-pressure refrigerant, and Xie et al. [41] quantified the effect of a sintered wick. Blasiak et al. [42] coupled a flow-pattern model to the wall temperature, Shi et al. [43] identified chaotic plug motion, and Takawale et al. [44] compared the regimes of flat-plate and capillary-tube devices. None of these addressed the top-heated/bottom-cooled orientation, and the regime descriptions they propose are specific to bottom heating, where gravity assists the return of condensate.
The present study has two objectives: to document by high-speed imaging how the internal flow of a closed-loop PHP reorganizes when the evaporator sits above the condenser, and to condense the observations into a regime map usable for diagnosis; and to quantify, through a one-dimensional force balance, which force dominates in this orientation and how the predicted plug amplitude compares with the recorded one. A previously reported module of the same orientation, cooled by direct contact, held its heater surface at 56.4 °C under 14 W and 25 °C coolant [11,12], a non-uniform three-dimensional channel has been shown to restore oscillation against gravity [9], an anti-gravity 3D PHP has been demonstrated for electric-vehicle batteries [10], and an open-loop L-shaped variant has since been optimized for 30-90 W [7]. Those studies fixed the thermal envelope but left the internal mechanism unresolved, which is the gap addressed here. The thermal resistance of the present device is also reported so that the flow observations can be read against a quantitative metric.

2. Experimental Method

2.1. Test Section and Working Fluid

A closed-loop PHP was fabricated from a borosilicate glass tube of 2 mm inner and 3 mm outer diameter, bent into a planar meander with a single U-turn (Figure 1). Glass was chosen so that the whole flow path stays optically accessible; the penalty is a wall conductivity two orders of magnitude below that of copper, which is discussed in Section 4.2. The evaporator, 100 mm long, carries a nichrome wire of 0.032 mm diameter wound on the outer wall, and the condenser is immersed in a thermostatically controlled bath.
The arrangement of the device relative to a battery cold plate is shown in Figure 2; the present closed-loop tube is the laboratory realization of that arrangement, which is dictated by the packaging of a traction battery that is cooled from below.
The test section is shown in Figure 3. Methanol was selected because its figure of merit is favourable at the present bore. The critical Bond number condition [45] gives a critical diameter of 3.2 mm for methanol, so that the 2 mm bore lies safely below the threshold at which surface tension can no longer sustain discrete plugs:
D cr = 2 σ g ( ρ l − ρ v )
The tube was evacuated to 0.06 Pa before charging. The charged volume fraction (VF), defined as the liquid volume divided by the total internal volume, was set to 8.5, 17.0 or 25.6 %; after charging the tube was sealed and leak-tested. The applied power was computed from the measured voltage and current,
Q = UI
with an uncertainty of ±3 % following the earlier studies of the same orientation [11,12,46].

2.2. Test Rig and Instrumentation

The rig (Figure 4) comprised the glass PHP, a high-speed camera (DSC-RX100M5, Sony, Japan), the constant-temperature bath, a DC power supply, a backlight and the thermocouples. K-type thermocouples (TT-K-36-SLE, Omega) were attached to the evaporator and condenser walls and read by a data logger (MX-100, Yokogawa, Japan). The voltage and current uncertainty of the supply was ±(0.1 % rdg + 5 digits) and the temperature uncertainty of the logger ±(0.05 % rdg + 0.7 °C). Images were recorded at 960 frames per second over 150 s for each condition and synchronized with the temperature record, so that every flow event could be associated with the instantaneous wall temperatures. One thermocouple was placed in the evaporator and one in the condenser: this is the minimum needed for the thermal resistance defined in Section 4.2, but it does not allow the wall-temperature uniformity to be assessed, which is acknowledged as a limitation.

2.3. Conditions and Uncertainty

Table 1 lists the test matrix: nine combinations of three heating powers and three filling ratios at a coolant inlet temperature of 20 °C. Each condition was repeated three times and the reported steady-state values are the means. Steady state was assumed once the evaporator temperature had fluctuated without a discernible trend for 10 min. The combined standard uncertainty of the measured temperature difference follows from two thermocouples and the logger, U(ΔT) = 1.5 K, which propagates to the thermal resistance as U(R) = U(ΔT)/Q, that is 0.09, 0.07 and 0.06 K/W at 17, 22 and 27 W; the corresponding error bars are drawn in Figure 9.
The thermal resistance reported in Section 4.2 was evaluated from the archived temperature-time records of this test campaign. The digital data-logger files from 2021-2022 are no longer available, so the pseudo-steady plateaus of the evaporator and condenser traces, reproduced in Figure 11, were read from the archived plots and converted to temperature with the axis calibration of each panel. The reading uncertainty introduced by this procedure is estimated at ±1.5 K on each temperature, which is of the same order as the thermocouple and logger uncertainty; the combined uncertainty of the temperature difference, U(ΔT) = 1.5 K, is used throughout. The absolute level of R is therefore subject to this digitization step, whereas the trends and the relative ranking of the filling ratios are not.
Table 1. Test matrix.
Table 1. Test matrix.
Working fluid Heating power Q (W) VF (%) at Tcool = 20 °C
Methanol 17 8.5
22 17.0
27 25.6

3. One-Dimensional Model of the Liquid Plug

A one-dimensional force balance was constructed to identify which force controls the oscillation in the top-heated orientation. The plug is treated as a rigid slug of constant mass bounded by two vapour slugs, with a thin liquid film left on the wall behind each advancing meniscus (Figure 5a). Four hypotheses are adopted: (i) the evaporator and condenser wall temperatures are constant over one cycle; (ii) the mass of each phase is conserved; (iii) the vapour pressure is uniform within a slug and the associated pressure loss is neglected; and (iv) phase change is confined to the film, so that the plug itself does not evaporate.
With these assumptions the equation of motion of the plug reads
F = Ff + Fp + Fc + Ft + G
where Ff is the wall friction, Fp the saturation-pressure difference across the plug, Fc the capillary pressure difference between the menisci, Ft the bend loss and G the gravity component. The acceleration follows from a first-order expansion in time,
a t = F m = u t + dt − u t dt
The gravity term is evaluated node by node along the meander. For node j, the gravitational force and its sum over the plug are
G = ∑ 1 k G j
G j = − g m i sin x j r ( − π r 2 < x t , j < π r 2 )
Gj = gmi
Gj = −gmi
where xt,j is the coordinate of node j at time t and θ the local inclination of the channel; the three branches correspond to the ascending leg, the crest and the descending leg. Because the evaporator is above the condenser, the ascending leg makes a negative contribution over the whole plug length, which is the quantitative expression of gravity suppression.
The vapour pressure follows from the Antoine equation [47], with a = 8.0274, b = 1574.99 and c = 238.87 for methanol:
P sat = 10 a − b T sat + c
The wall friction is written in terms of a friction coefficient [33],
F f = 1 2 c f ρ l v l a w
the bend loss in terms of the local dynamic head [36],
F t = f turn L l ρ l v l a w 2 D i
and the capillary pressure through a capillary-number correlation [36,37],
F c = 5.44 ( R e C a ) 0.33 μ l v l D i a w
Position and velocity are advanced by a Taylor expansion [33,34],
x t + dt , j − x t , j = x t , j ' 1 ! dt + x t , j '' 1 ! dt 2 + …
xt+dt,j − xt,j = utdt + at(dt)2
Heat transfer is resolved separately in the liquid and vapour phases (Figure 6). In the plug the convective coefficient follows from a laminar entry-length correlation and, once the flow is fully developed, from the Dittus-Boelter relation [48]:
N u = 1.86 ( R e P r D i L l ) 1 3
N u = 0.023 R e 0.8 P r 1 3
h = N u k l D i
In the evaporator the film evaporation coefficient is taken from the Kandlikar correlation [49] and in the condenser the condensation coefficient from the Nusselt solution [50], both corrected for the reduced pressure of the evacuated tube:
h e = 0.32 ( ρ l 0.65 k l 0.3 c p , l 0.7 g 0.2 q e 0.4 ρ v 0.25 h fg 0.4 μ l 0.1 ) ( p sat p ) 0.3
h c = 0.943 ( ρ l gk l 3 ( ρ l − ρ v ) ( h fg + 0.68 c p , l ( T sat − T w ) ) μ l L c ( T sat − T w ) ) ( p sat p ) 0.3
The net heat flow into the vapour phase, and hence the vapour temperature at the next time step, follows from an energy balance on the slug:
T v , t + dt = T v , t + dQ Cp v m v
Figure 7. Solution sequence of the one-dimensional model.
Figure 7. Solution sequence of the one-dimensional model.
Preprints 240452 g007
Marching Eqs. (3)-(20) in time, with the measured evaporator temperature as the boundary condition, yields the instantaneous position, velocity and temperature of the plug. The model contains no tuned coefficient other than the friction factor correlation, so that the comparison in Section 4.6 is a prediction rather than a fit.

4. Results and Discussion

4.1. Coupled Temperature and Flow Response

Figure 8 shows four successive frames of the same plug together with the simultaneous temperature record. The two traces respond to the arrival of the phases: when a plug passes a measuring station the local wall temperature falls, and when a vapour slug occupies it the temperature rises. The record therefore acts as a proxy for plug position and confirms that the plug traverses the full length of the evaporator rather than oscillating about a fixed point. The amplitude of the wall-temperature oscillation grows with heating power, from about 6 K at 17 W to about 9 K at 27 W at 8.5 % filling ratio, which is the thermal signature of the larger plug excursion reported in Section 4.4.

4.2. Thermal Resistance

The thermal resistance is defined as R = (Teva - Tcon)/Q, with the evaporator and condenser wall temperatures averaged over the pseudo-steady window of each record; as explained in Section 2.3, these plateaus were read from the archived temperature traces. Figure 9 presents the result and three features stand out. First, R decreases with heating power at every filling ratio, from 1.43 to 1.19 K/W at 8.5 %, from 1.91 to 1.65 K/W at 17.0 % and from 3.85 to 2.11 K/W at 25.6 %. The rise in evaporator temperature raises the saturation pressure and hence the pressure difference available to drive the plugs, so that the device becomes more effective as the load grows. Second, R increases steeply with filling ratio: the mean over the three powers is 1.25 K/W at 8.5 %, 1.89 K/W at 17.0 % and 3.03 K/W at 25.6 %, a factor of 2.4 between the extremes. Underfilling is therefore favourable here, in contrast to the 15 % optimum reported for a bottom-heated open-loop device [7]. The reason is visible in Section 4.4: at 25.6 % the condenser is flooded, the vapour space needed to absorb expansion is absent, and the plug is locked in B-type motion. Third, the curves at 8.5 % and 17.0 % are not monotonic, the value at 22 W being lower than that at 27 W. Two readings are possible, the intermittent dry-out of the evaporator [21,40] and the limited number of measuring stations. With one thermocouple per section, a dry-out episode occupying part of the 10 min window shifts the mean evaporator temperature without a corresponding change in the condenser, and this artefact rather than a physical optimum is the origin of the non-monotonicity. It must also be stressed that the absolute values of R are governed by the glass wall, whose conductivity is two orders of magnitude below that of copper; the present 1.1-3.9 K/W therefore cannot be compared with the 0.4-0.5 K/W of copper devices [7], and the significance of Figure 9 lies in the trends and in the ranking of the filling ratios, not in the absolute level.
Figure 9. Thermal resistance of the present PHP against heating power and filling ratio: (a) R = (Teva - Tcon)/Q with error bars from U(ΔT) = 1.5 K; (b) the corresponding temperature difference.
Figure 9. Thermal resistance of the present PHP against heating power and filling ratio: (a) R = (Teva - Tcon)/Q with error bars from U(ΔT) = 1.5 K; (b) the corresponding temperature difference.
Preprints 240452 g009

4.3. Flow Regime Classification

The images were classified by the way a liquid plug loses its identity. Three families emerge, illustrated in Table 2 and specified in Table 3. In type A the plug disappears by evaporation, in the middle of the evaporator (A-1), at its upper end (A-2), or, in the limiting case A-3, after crossing the crest into the neighbouring turn. Type A requires a low filling ratio, because only then is the vapour space large enough to absorb the vapour generated. In type B the plug oscillates without leaving the condenser and adiabatic sections; the subtypes differ in period and amplitude, B-1 being short in both, B-2 short in period and long in amplitude, B-3 long in period and small in amplitude, and B-4 and B-5 respectively growing and decaying. Type B dominates at high filling ratio. In type C the plug migrates from one turn to the next, either once (C-1), simultaneously with evaporation in an adjacent turn (C-2), or back and forth (C-3). Type C requires both a high filling ratio and a high power, because only then is the pressure difference sufficient to lift a long liquid column over the crest.
Because the classification rests on visual judgement, a complete sequence is given in Figure 10, in which one condition (27 W, 25.6 %) is decomposed as B1 → A2 → A1 → B1 → C2, and the thermal and flow interpretation of each transition is given in the caption. The sequence begins with pressure build-up under an almost static plug, proceeds through the coalescence of vapour at the upper end of the evaporator, and ends with the migration of a plug into the adjacent turn. This symbolic rendering, rather than an instantaneous photograph, is what makes the filling ratios comparable.

4.4. Effect of Heating Power and Filling Ratio

The top row of Figure 11 assembles the sequences at 8.5 % filling ratio. At this ratio the plug rises from the condenser into the evaporator and then disappears (type A), and the number of oscillations per unit time increases with power, so that the motion changes from B-1 at 17 W to a repeated A-B alternation at 27 W. The middle row of Figure 11 shows the sequences at 17.0 %. At 17 W the record is dominated by long-period, small-amplitude motion (B-3); as the power is raised to 22 and 27 W the B-type share falls and C-type events appear, in which the plug crosses the first crest into the neighbouring tube. The bottom row of Figure 11 shows the behaviour at 25.6 %; here B-3 again dominates at 17 W, but the transition to C-type is more pronounced and the plug spends an increasing part of the cycle in the turn. The resulting map, Table 3, places A-type motion in the low-filling-ratio corner, B-type along the high-filling-ratio edge and C-type at the intersection of high power and high filling ratio.
Two mechanisms behind the map deserve emphasis. At high filling ratio the condenser is occupied by liquid, the temperature and pressure gradients available to accelerate the plug are small, and the extra mass reduces the acceleration for a given driving force, so that only B-type motion survives. At low filling ratio the opposite holds: the vapour space is large, the pressure difference generated per unit heat input is small, but the plug mass is also small and the plug can be expelled over the crest before it evaporates. This is also why the A-type regimes coexist with a low thermal resistance: expelling liquid into the evaporator wets a surface that would otherwise dry out, and it is the mechanism by which a gravity-suppressed PHP avoids the dry-out limit reported for bottom-heated devices [21] and visualized for low-pressure refrigerants by Bao et al. [40].
Figure 11. Transient plug motion for the nine test conditions: rows correspond to charged volume fractions of 8.5, 17.0 and 25.6 %, and columns to heating powers of 17, 22 and 27 W. Panels (a)-(i) are labelled in reading order.
Figure 11. Transient plug motion for the nine test conditions: rows correspond to charged volume fractions of 8.5, 17.0 and 25.6 %, and columns to heating powers of 17, 22 and 27 W. Panels (a)-(i) are labelled in reading order.
Preprints 240452 g011
Table 3. Regime map of the liquid plug as a function of filling ratio and heating power.
Table 3. Regime map of the liquid plug as a function of filling ratio and heating power.
Heating power VF = 8.5 % (low) VF = 17.0 % (medium) VF = 25.6 % (high)
17 W (low) A-1 → A-2 B-3 B-3
22 W (medium) A-2 → B-1 B-2 → C-1 B-2 → C-2
27 W (high) A-1 → A-3 C-1 → C-2 C-2 → C-3

4.5. Driving forces

Figure 12 shows the transient forces acting on the plug. Vapour pressure dominates throughout, reaching 0.12 N, followed by wall friction at 0.06 N, the bend loss, the capillary force and finally gravity, whose contribution stays below 5 % of the total. The ordering is the central result of the force analysis: in this orientation the device is not gravity-limited in the sense of being unable to return condensate, but gravity-limited in the sense that it must overcome a persistent adverse component along the whole ascending leg. The capillary force is small because the bore lies well below the critical diameter, so that the menisci are nearly hemispherical and contact-angle hysteresis contributes little [37].

4.6. Model Predictions

Figure 13 shows the calculated response to evaporator temperature. As Teva rises from 50 to 70 °C the maximum displacement grows from 8.6 to 11.7 mm, the vapour pressure rises, and both the acceleration and the velocity of the plug increase; the friction grows with velocity, so the net gain in amplitude is sub-linear. The lower row of Figure 13 shows the corresponding response to filling ratio: amplitude and frequency both fall as VF rises, because a heavier plug needs a larger driving force to surmount the crest. This is the computational counterpart of the experimental finding that underfilling is favourable, and it explains why the wall friction increases up to VF = 10 % and then falls, since beyond that point the plug velocity collapses and the friction, which scales with the square of velocity, collapses with it.
Figure 14 compares the predicted amplitude with the measured one. At low filling ratio and an evaporator temperature of 60-80 °C the model predicts a maximum amplitude of 0.142 m against 0.132-0.155 m observed; at high filling ratio it predicts 0.059 m against 0.023-0.050 m observed. The agreement is within 0.013 m at low filling ratio, and the model reproduces the correct order at high filling ratio but over-predicts there, and the discrepancy is systematic rather than random. Two causes are identified. The model neglects the heat capacity of the glass wall, which is large compared with that of the working fluid and damps the oscillation; and it treats the plug as rigid, whereas the images show partial break-up at high filling ratio. The model is therefore adequate for ranking the driving forces and for identifying the controlling parameters, but not for predicting the absolute amplitude of a flooded device.

5. Conclusions

A closed-loop glass PHP charged with methanol was operated with the evaporator above the condenser, visualized at 960 frames per second and modelled with a one-dimensional force balance. The following conclusions are drawn.
(1) A flow-regime map for the top-heated/bottom-cooled orientation is established. Eleven regimes are grouped into three families: evaporation froth (A), oscillation confined to the condenser and adiabatic sections (B) and turn-to-turn migration (C). Type A occupies the low-filling-ratio corner, type B the high-filling-ratio edge, and type C the region of simultaneously high power and high filling ratio.
(2) Vapour pressure is the dominant driving force, reaching 0.12 N and twice the wall friction; the bend loss, the capillary force and gravity follow in that order, gravity contributing less than 5 %. Gravity suppression therefore manifests itself as a persistent adverse component rather than as an inability to return condensate.
(3) Thermal resistance falls with heating power and rises steeply with filling ratio, from 1.13-1.43 K/W at 8.5 % to 2.11-3.85 K/W at 25.6 %, a factor of 2.4. Underfilling, not the 15 % optimum reported for bottom-heated devices, is the favourable operating point here, and the mechanism is the expulsion of liquid over the crest, which rewets an evaporator that would otherwise dry out.
(4) The one-dimensional model reproduces the measured plug amplitude within 0.013 m at low filling ratio and the correct order at high filling ratio, but over-predicts there because the wall heat capacity and the break-up of the plug are not represented.
The map is directly usable for diagnosis: a flooded module announces itself through the dominance of B-3, and a dry-out-prone module through the dominance of A-1 and A-2, so that the filling ratio can be corrected before the thermal resistance degrades. Extending the map to wider ranges of power and to coolants other than water, and replacing the single thermocouple per section by a distributed array so that wall uniformity can be resolved, are the natural next steps.

Author Contributions

Conceptualization, Z.G. and R.C.; methodology, Z.G.; investigation, Z.G., X.Y. and Y.Z.; data curation, Y.Z.; formal analysis, Z.G.; visualization, Y.Z.; writing-original draft preparation, Z.G.; writing-review and editing, Y.S. and R.C.; supervision, Y.S. and R.C.; project administration, R.C.; funding acquisition, Y.S. and R.C. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by the Natural Science Foundation of Heilongjiang Province, China (grant numbers PL2024E017 ), and by the Heilongjiang Provincial Ecological and Environmental Protection Research Project, China (grant number HST2025GF004).

Data Availability Statement

The image sequences and the temperature traces underlying Figure 8, Figure 9, Figure 10, Figure 11, Figure 12, Figure 13 and Figure 14 are included in the article. The raw high-speed video files and the original data-logger files are available from the corresponding author on reasonable request; the resolution of the thermal-resistance data is discussed in Section 2.3.

Acknowledgments

The authors gratefully acknowledge the financial support of the Natural Science Foundation of Heilongjiang Province, China (grant numbers PL2024E017). The authors also thank the Heilongjiang Provincial Environmental Science Research Institute for administrative support of project HST2025GF004.

Conflicts of Interest

The authors declare no conflicts of interest.

Nomenclature

a Antoine constant
at acceleration of the liquid plug, m s⁻²
Aw cross-sectional area of the tube, m²
b Antoine constant
c Antoine constant
cf friction coefficient
Ca capillary number, μl ul/σ
cp,l specific heat of the liquid, J kg⁻¹ K⁻¹
cp,v specific heat of the vapour, J kg⁻¹ K⁻¹
Dcr critical diameter, m
Di inner diameter, m
Do outer diameter, m
F sum of forces on the plug, N
Fc capillary force, N
Ff wall friction, N
Fp saturation pressure force, N
Ft bend pressure loss, N
fturn bend loss coefficient
g gravitational acceleration, m s⁻²
G gravity force, N
h convective heat transfer coefficient, W m⁻² K⁻¹
hc condensation coefficient, W m⁻² K⁻¹
he evaporation coefficient, W m⁻² K⁻¹
hfg latent heat, J kg⁻¹
I electric current, A
kl liquid thermal conductivity, W m⁻¹ K⁻¹
Lc length of the condenser, m
Le length of the evaporator, m
Ll length of the liquid slug, m
m mass of the liquid plug, kg
mj mass of node j, kg
Nu Nusselt number
P pressure, Pa
Psat saturation pressure, Pa
Pr Prandtl number
Q heating power, W
qe heat flux at the evaporator, W m⁻²
qv net heat flow into the vapour, W
R thermal resistance, K W⁻¹
Rb radius of the bend, m
Re Reynolds number
t time, s
Tcon condenser temperature, °C
Tcool coolant inlet temperature, °C
Teva evaporator temperature, °C
Tsat saturation temperature, °C
Tv vapour temperature, °C
Tw wall temperature, °C
U voltage, V
ul velocity of the liquid plug, m s⁻¹
VF charged volume fraction, %
xt,j position of node j at time t, m
ΔT evaporator-condenser temperature difference, K
μl liquid dynamic viscosity, Pa s
ρl liquid density, kg m⁻³
ρv vapour density, kg m⁻³
σ surface tension, N m⁻¹

References

  1. Ouchi, S.; Kurose, K.; Miyata, K. Mechanism of Transition between Oscillating and Pulsating–Circulating Flows in Bottom-Heated Pulsating Heat Pipe Based on Simple Simulation Model. Int. J. Therm. Sci. 2025, 217, 110035. [CrossRef]
  2. Akachi, H. Structure of a Heat Pipe. U.S. Patent 4,921,041, 1 May 1990.
  3. Khandekar, S. An Insight into Thermo-Hydrodynamic Coupling in Closed Loop Pulsating Heat Pipes. Int. J. Therm. Sci. 2004, 43, 13–20. [CrossRef]
  4. Miyazaki, Y. Oscillatory Flow in the Pulsating Heat Pipe. In Proceedings of the 11th International Heat Pipe Conference, Tokyo, Japan, 1999; pp. 367–372.
  5. Shafii, M.B.; Faghri, A. Thermal Modeling of Unlooped and Looped Pulsating Heat Pipes. J. Heat Transf. 2001, 123, 1159–1172. [CrossRef]
  6. Nikolayev, V.S. A Dynamic Film Model of the Pulsating Heat Pipe. J. Heat Transf. 2011, 133, 081504. [CrossRef]
  7. Chi, R.; Wang, J.; Ning, H.; Ye, Y.; Lu, Z.; Chen, H.; Yang, R. Series-Connected Open-Loop L-Shaped Pulsating Heat Pipes for Lithium-Ion Battery Thermal Management: Experimental Optimization of Heat Transfer Performance in EV-Applicable Scenarios. Int. J. Heat Fluid Flow 2026, 117, 110146. [CrossRef]
  8. Fan, S.; Xu, Z.; Li, W.; Liu, Y.; Chang, H. Thermo-Fluidic Symmetry Breaking in Auxiliary-Branched Pulsating Heat Pipe: Gravity-Adaptive Oscillation Enhancement. Int. Commun. Heat Mass Transf. 2025, 169, 109798. [CrossRef]
  9. Tseng, C.Y.; Yang, K.S.; Wang, C.C. Non-Uniform Three-Dimensional Pulsating Heat Pipe for Anti-Gravity High-Flux Applications. Energies 2020, 13, 3068. [CrossRef]
  10. Lee, J.S.; Kim, S.J.; Han, W.S.; Rhi, S.H. Anti-Gravity 3D Pulsating Heat Pipe for Cooling Electric Vehicle Batteries. Energies 2024, 17, 2283. [CrossRef]
  11. Chi, R.G.; Chung, W.S.; Rhi, S.H. Thermal Characteristics of an Oscillating Heat Pipe Cooling System for Electric Vehicle Li-Ion Batteries. Energies 2018, 11, 655. [CrossRef]
  12. Chi, R.G.; Rhi, S.H. Oscillating Heat Pipe Cooling System of Electric Vehicle’s Li-Ion Batteries with Direct Contact Bottom Cooling Mode. Energies 2019, 12, 1698. [CrossRef]
  13. Yang, H.; Khandekar, S.; Groll, M. Performance Characteristics of Pulsating Heat Pipes as Integral Thermal Spreaders. Int. J. Therm. Sci. 2009, 48, 815–824. [CrossRef]
  14. Yang, H.; Khandekar, S.; Groll, M. Operational Limit of Closed Loop Pulsating Heat Pipes. Appl. Therm. Eng. 2008, 28, 49–59. [CrossRef]
  15. Wang, S.F.; Nishio, S. Heat Transport Characteristics in Closed Loop Pulsating Heat Pipes. In Proceedings of the ASME Summer Heat Transfer Conference, San Francisco, CA, USA, 2005; pp. 1–6.
  16. Rittidech, S.; Terdtoon, P.; Murakami, M.; Kamonpet, P.; Jompakdee, W. Correlation to Predict Heat Transfer Characteristics of a Closed-End Pulsating Heat Pipe at Normal Operating Condition. Appl. Therm. Eng. 2003, 23, 497–510. [CrossRef]
  17. Tseng, C.Y.; Yang, K.S.; Chien, K.H.; Jeng, M.S.; Wang, C.C. Investigation of the Performance of Pulsating Heat Pipe Subject to Uniform/Alternating Tube Diameters. Exp. Therm. Fluid Sci. 2014, 54, 85–92. [CrossRef]
  18. Hathaway, A.A.; Wilson, C.A.; Ma, H.B. Experimental Investigation of Uneven-Turn Water and Acetone Pulsating Heat Pipes. J. Thermophys. Heat Transf. 2012, 26, 115–122. [CrossRef]
  19. Sarangi, R.K.; Rane, M.V. Experimental Investigations for Start-Up and Maximum Heat Load of Closed Loop Pulsating Heat Pipe. Procedia Eng. 2013, 51, 683–687. [CrossRef]
  20. Saha, M.; Feroz, C.M.; Ahmed, F.; Mujib, T. Thermal Performance of an Open Loop Closed End Pulsating Heat Pipe. Heat Mass Transf. 2012, 48, 259–265. [CrossRef]
  21. Katpradit, T.; Wongratanaphisan, T.; Terdtoon, P.; Rittidech, S.; Chareonsawan, P.; Waowaew, S. Effect of Aspect Ratios and Bond Number on Internal Flow Patterns of Closed End Pulsating Heat Pipe at Critical State. In Proceedings of the 13th International Heat Pipe Conference, Shanghai, China, 2004; pp. 298–303.
  22. Zuo, Z.J.; North, M.T.; Ray, L. Combined Pulsating and Capillary Heat Pipe Mechanism for Cooling of High Heat Flux Electronics. In Proceedings of the ASME Heat Transfer Devices Conference, 1999; pp. 237–243.
  23. Zuo, J.; North, M.T.; Wert, K.L. High Heat Flux Heat Pipe Mechanism for Cooling of Electronics. IEEE Trans. Compon. Packag. Technol. 2011, 24, 220–225.
  24. Liu, S.; Li, J.; Dong, X.; Chen, H. Experimental Study on Flow Patterns and Improved Configurations for Pulsating Heat Pipes. J. Therm. Sci. 2007, 16, 56–62. [CrossRef]
  25. Tong, B.Y.; Wong, T.N.; Ooi, K.T. Closed-Loop Pulsating Heat Pipe. Appl. Therm. Eng. 2001, 21, 1845–1862. [CrossRef]
  26. Qu, J.; Tong, W.; Ma, T. Experimental Investigation on Flow and Heat Transfer of a Pulsating Heat Pipe. In Proceedings of the 12th International Heat Pipe Conference, Moscow, Russia, 2002; pp. 226–231.
  27. Khandekar, S. Thermofluid Dynamic Study of Flat-Plate Closed-Loop Pulsating Heat Pipes. Microscale Thermophys. Eng. 2003, 6, 303–317. [CrossRef]
  28. Borgmeyer, B.; Ma, H.B. Experimental Investigation of Oscillating Motions in a Flat Plate Pulsating Heat Pipe. J. Thermophys. Heat Transf. 2007, 21, 405–409. [CrossRef]
  29. Chien, K.H.; Chen, Y.R.; Lin, Y.T.; Wang, C.C.; Yang, K.S. The Experimental Studies of Flat-Plate Closed-Loop Pulsating Heat Pipes. In Proceedings of the 10th International Heat Pipe Symposium, Taipei, Taiwan, 2011; pp. 212–216.
  30. Bhuwakietkumjohn, N.; Rittidech, S. Internal Flow Patterns on Heat Transfer Characteristics of a Closed-Loop Pulsating Heat Pipe with Check Valves Using Ethanol and a Silver Nano-Ethanol Mixture. Exp. Therm. Fluid Sci. 2010, 34, 1000–1007. [CrossRef]
  31. Rittidech, S.; Sangiamsuk, S. Internal Flow Patterns on Heat Transfer Performance of a Closed Loop Pulsating Heat Pipe with Check Valves. Exp. Heat Transf. 2012, 25, 48–57. [CrossRef]
  32. Das, S.P.; Nikolayev, V.S.; Lefevre, F.; Pottier, B.; Khandekar, S.; Bonjour, J. Thermally Induced Two-Phase Oscillating Flow inside a Capillary Tube. Int. J. Heat Mass Transf. 2010, 53, 3905–3913. [CrossRef]
  33. Gursel, G.; Frijns, A.J.H.; Homburg, F.G.A.; van Steenhoven, A.A. A Mass-Spring-Damper Model of a Pulsating Heat Pipe with a Non-Uniform and Asymmetric Filling. Appl. Therm. Eng. 2015, 91, 80–90. [CrossRef]
  34. Yang, X.S.; Luan, T. Modelling of a Pulsating Heat Pipe and Start-Up Asymptotics. Procedia Comput. Sci. 2012, 9, 784–791. [CrossRef]
  35. Daimaru, T.; Yoshida, S.; Nagai, H. Study on Thermal Cycle in Pulsating Heat Pipes by Numerical Analysis. Appl. Therm. Eng. 2016, 113, 1219–1227. [CrossRef]
  36. Kreutzer, M.T.; Kapteijn, F.; Moulijn, J.A.; Kleijn, C.R.; Heiszwolf, J.J. Inertial and Interfacial Effects on Pressure Drop of Taylor Flow in Capillaries. AIChE J. 2005, 51, 2428–2440. [CrossRef]
  37. Qu, J.; Sun, Q.; Wang, Q. Effect of Contact Angle Hysteresis on the Fluid Movement Characteristics in Pulsating Heat Pipe. J. Eng. Thermophys. 2015, 36, 1990–1994.
  38. Cheng, P.S.; Wong, S.C. Detailed Visualization Experiments on the Start-Up Process and Stable Operation of Pulsating Heat Pipes: Effects of Internal Diameter. Int. J. Heat Fluid Flow 2024, 106, 109325. [CrossRef]
  39. Sun, X.; Jia, L. Visual Experimental Study on Flat-Plate Pulsating Heat Pipe with Double Condensers. Int. J. Heat Fluid Flow 2025, 114, 109831. [CrossRef]
  40. Bao, K.; Liu, Y.; Yan, Y.; Ye, G.; Han, X. Partial Visualization Study on Flow, Start-Up and Heat Transfer Characteristics of Closed-Loop Pulsating Heat Pipe with R1336mzz(Z). Appl. Therm. Eng. 2023, 226, 120218. [CrossRef]
  41. Xie, Y.; Yin, Y.; Zhou, S.; Liu, X.; Pan, Y. Visualization Analysis of Heat Transfer and Flow Behavior in Flat-Plate Pulsating Heat Pipe with Sintered Powder Wick Layer. Int. Commun. Heat Mass Transf. 2025, 167, 109326. [CrossRef]
  42. Błasiak, P.; Opalski, M.; Parmar, P.; Czajkowski, C.; Pietrowicz, S. The Thermal–Flow Processes and Flow Pattern in a Pulsating Heat Pipe—Numerical Modelling and Experimental Validation. Energies 2021, 14, 5952. [CrossRef]
  43. Shi, W.; Chang, H.; Chen, H.; Pan, L. Chaotic Flow in a Closed-Loop Pulsating Heat Pipe. Case Stud. Therm. Eng. 2025, 71, 106162. [CrossRef]
  44. Takawale, A.; Abraham, S.; Sielaff, A.; Mahapatra, P.S.; Pattamatta, A.; Stephan, P. A Comparative Study of Flow Regimes and Thermal Performance between Flat Plate Pulsating Heat Pipe and Capillary Tube Pulsating Heat Pipe. Appl. Therm. Eng. 2019, 149, 613–624. [CrossRef]
  45. Lin, Y.H.; Kang, S.W.; Chen, H.L. Effect of Silver Nano-Fluid on Pulsating Heat Pipe Thermal Performance. Appl. Therm. Eng. 2008, 28, 1312–1317. [CrossRef]
  46. Cui, X.; Zhu, Y.; Li, Z.; Shun, S. Combination Study of Operation Characteristics and Heat Transfer Mechanism for Pulsating Heat Pipe. Appl. Therm. Eng. 2014, 65, 394–402. [CrossRef]
  47. Yaws, C.L.; Yang, H.C. To Estimate Vapor Pressure Easily. Hydrocarb. Process. 1989, 68, 65–68.
  48. Incropera, F.P.; DeWitt, D.P.; Bergman, T.L.; Lavine, A.S. Fundamentals of Heat and Mass Transfer, 6th ed.; Wiley: New York, NY, USA, 2007.
  49. Kandlikar, S.G. A General Correlation for Saturated Two-Phase Flow Boiling Heat Transfer inside Horizontal and Vertical Tubes. J. Heat Transf. 1990, 112, 219–228. [CrossRef]
  50. Faghri, A. Heat Pipe Science and Technology; Taylor & Francis: London, UK, 199.
Figure 1. Geometry and operating principle of the pulsating heat pipe.
Figure 1. Geometry and operating principle of the pulsating heat pipe.
Preprints 240452 g001
Figure 2. Top-heated/bottom-cooled arrangement used for battery cooling (redrawn after [12]).
Figure 2. Top-heated/bottom-cooled arrangement used for battery cooling (redrawn after [12]).
Preprints 240452 g002
Figure 3. Photograph of the glass PHP: evaporator with wound nichrome wire, adiabatic section and condenser.
Figure 3. Photograph of the glass PHP: evaporator with wound nichrome wire, adiabatic section and condenser.
Preprints 240452 g003
Figure 4. Visualization rig: camera, backlight, glass PHP, coolant bath, DC supply and data logger.
Figure 4. Visualization rig: camera, backlight, glass PHP, coolant bath, DC supply and data logger.
Preprints 240452 g004
Figure 5. Physical model: (a) liquid plug bounded by vapour slugs and a wall film; (b) forces acting on the plug.
Figure 5. Physical model: (a) liquid plug bounded by vapour slugs and a wall film; (b) forces acting on the plug.
Preprints 240452 g005aPreprints 240452 g005b
Figure 6. Heat transfer paths: (a) liquid phase; (b) vapour phase.
Figure 6. Heat transfer paths: (a) liquid phase; (b) vapour phase.
Preprints 240452 g006
Figure 8. Transient response at 17 W and 8.5 %: (a)-(d) successive frames of the plug; (e) evaporator and condenser wall temperatures.
Figure 8. Transient response at 17 W and 8.5 %: (a)-(d) successive frames of the plug; (e) evaporator and condenser wall temperatures.
Preprints 240452 g008
Figure 10. Symbolic rendering of the dynamic flow behaviour at Q = 27 W and VF = 25.6 %. The sequence runs B1 → A2 → A1 → B1 → C2 and is marked ①-⑤ on the figure. Pressure rises with minimal oscillatory vibration before ②, falls with the temperature between ② and ③, remains quasi-static around ④, and rises again with minimal vibration before ⑤; the plug pulsates during A1 and A2 and migrates during C2.
Figure 10. Symbolic rendering of the dynamic flow behaviour at Q = 27 W and VF = 25.6 %. The sequence runs B1 → A2 → A1 → B1 → C2 and is marked ①-⑤ on the figure. Pressure rises with minimal oscillatory vibration before ②, falls with the temperature between ② and ③, remains quasi-static around ④, and rises again with minimal vibration before ⑤; the plug pulsates during A1 and A2 and migrates during C2.
Preprints 240452 g010
Figure 12. Transient force analysis: (a) wall friction and saturation pressure; (b) bend loss, gravity and capillary force.
Figure 12. Transient force analysis: (a) wall friction and saturation pressure; (b) bend loss, gravity and capillary force.
Preprints 240452 g012
Figure 13. Calculated response of the plug: (a-d) as a function of evaporator temperature, showing (a) displacement, (b) saturation pressure, (c) plug velocity and (d) wall friction; (e-h) as a function of charged volume fraction, showing the same four quantities.
Figure 13. Calculated response of the plug: (a-d) as a function of evaporator temperature, showing (a) displacement, (b) saturation pressure, (c) plug velocity and (d) wall friction; (e-h) as a function of charged volume fraction, showing the same four quantities.
Preprints 240452 g013
Figure 14. Measured and calculated plug amplitude: (a) VF = 8.5 %; (b) VF = 25.6 %.
Figure 14. Measured and calculated plug amplitude: (a) VF = 8.5 %; (b) VF = 25.6 %.
Preprints 240452 g014
Table 2. Classification of the flow regimes of the liquid plug.
Table 2. Classification of the flow regimes of the liquid plug.
Family Regime Schematic diagram Diagnostic features
A evaporation froth A-1 Preprints 240452 i001 Plug vanishes in the middle of the evaporator; low VF
A-2 Preprints 240452 i002 Plug vanishes at the upper end of the evaporator; low VF
A-3 Preprints 240452 i003 Plug vanishes in the evaporator of the adjacent turn; high VF, high Q
B oscillation B-1 Preprints 240452 i004 Short period, small amplitude; confined to condenser and adiabatic sections; low VF
B-2 Preprints 240452 i005 Short period, large amplitude; low VF
B-3 Preprints 240452 i006 Long period, small amplitude; high VF, low Q
B-4 Preprints 240452 i007 Long period, amplitude growing with time; high VF
B-5 Preprints 240452 i008 Long period, amplitude decaying with time; high VF
C turn-to-turn migration C-1 Preprints 240452 i009 Plug migrates to the condenser of the adjacent turn; high VF, high Q
C-2 Preprints 240452 i010 A-3 and C-1 in different turns at the same instant; high VF, high Q
C-3 Preprints 240452 i011 Plug oscillates back and forth between adjacent turns; high VF, high Q
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.
Copyright: This open access article is published under a Creative Commons CC BY 4.0 license, which permit the free download, distribution, and reuse, provided that the author and preprint are cited in any reuse.