Submitted:
21 October 2026
Posted:
22 October 2026
You are already at the latest version
Abstract
Gravitational-wave observations of compact binary coalescences encode the masses and other physical properties of their sources. Bayesian parameter estimation is the established framework for extracting this information, but its reliance on repeated likelihood evaluations makes it computationally demanding. Neural posterior estimation (NPE) offers a simulation-based alternative that learns an amortized approximation to the posterior from simulated pairs of source parameters and observations. Whether such an estimator remains accurate and statistically calibrated when the noise level or the source parameters depart from the training distribution, however, has not been examined in a fully controlled setting. We present a reproducible computational framework for testing physics-guided NPE of the chirp mass ℳc and mass ratio q of non-spinning, quasi-circular binary black hole inspirals. Synthetic frequency-domain signals are generated with a post-Newtonian stationary-phase (TaylorF2) waveform truncated at a controlled order, and stationary Gaussian noise is injected at optimal signal-to-noise ratios p ∈ {8,12,20,30}. We show analytically that at leading (Newtonian) order the waveform depends on the component masses only through ℳc, so that q is unidentifiable; this property is exploited as a physics-based null test of posterior calibration. The neural estimator is compared with a waveform-optimization point estimator, a multilayer-perceptron regressor and a likelihood-based Bayesian reference analysis that share identical waveforms, priors and noise assumptions. Performance is assessed through parameter-recovery error, signed bias, empirical credible-interval coverage, robustness to signal-to-noise and distribution shift, and the amortization break-even point of the computational cost. Fisher-information bounds provide an independent analytic benchmark for the expected ρ-1 scaling of the parameter uncertainties. The framework separates accuracy, calibration and computational advantage, and provides a reproducible baseline for subsequent studies with higher-order waveforms and realistic detector noise.
Keywords:
gravitational waves
; binary black holes
; chirp mass
; mass ratio
; Bayesian inference
; neural posterior estimation
; simulation-based inference
; normalizing flows
; posterior calibration
1. Introduction
The direct detection of gravitational waves from the binary black hole merger GW150914 [1] opened an observational window on compact astrophysical systems and on the strong-field regime of general relativity. Since then, the LIGO–Virgo–KAGRA collaboration has reported close to one hundred compact binary coalescences [2]. As two black holes orbit one another, the system loses orbital energy to gravitational radiation [3,4]; the orbit shrinks and both the orbital frequency and the frequency of the emitted wave increase as the binary approaches merger.
Estimating the source parameters of a binary from a measured signal is an inverse problem. The forward problem maps a set of physical parameters to a predicted waveform , whereas the inverse problem infers from noisy data. The inverse problem is complicated by detector noise, strong correlations between parameters, waveform-model uncertainty and the cost of evaluating the likelihood [5,6]. Bayesian inference provides a principled treatment of these difficulties [7], and stochastic samplers implemented in libraries such as LALInference [8] and Bilby [9] are now standard. Their main drawback is cost: each new event requires millions of waveform and likelihood evaluations.
Machine-learning methods have therefore been developed to accelerate gravitational-wave inference [10]. Simulation-based inference (SBI) [11] replaces explicit likelihood evaluation by learning from simulations. In neural posterior estimation (NPE) [12], a conditional density estimator — typically a normalizing flow [13,14] — is trained to approximate the posterior directly, so that inference on a new observation reduces to a single forward pass. Following early demonstrations with conditional variational autoencoders [15] and normalizing flows [16], NPE has been applied to real detector data [17], combined with importance sampling to recover asymptotically exact posteriors [18], implemented with convolutional architectures [19] and extended to intermediate-mass binaries in real noise [20]. Neural likelihood estimators provide a complementary route [21,22].
Two issues remain insufficiently isolated in this literature. First, a low average estimation error does not guarantee statistically calibrated uncertainties: SBI posteriors can be systematically overconfident [23]. Second, the term “physics-informed” [24] is frequently applied to any network trained on physically generated data, which conflates the provenance of the training set with an explicit, testable physical constraint. Disentangling these effects requires a controlled setting in which the true parameters are known, the noise statistics are specified exactly, and the physical content of the model can be switched on and off.
In this work we construct such a setting for a deliberately restricted problem: inference of the chirp mass and mass ratio of non-spinning, quasi-circular binary black hole inspirals from synthetic frequency-domain signals. The contributions of this paper are as follows. (i) We formulate a fully specified simulation and inference pipeline, including waveform, noise, prior and inner-product conventions, so that neural and likelihood-based analyses are compared under identical assumptions. (ii) We show that the leading-order waveform carries no information on , and use this exact degeneracy as a physics-based null test of posterior calibration. (iii) We define “physics-guided” operationally and specify an ablation design that isolates its contribution. (iv) We provide Fisher-information bounds as an analytic benchmark and an amortization break-even criterion for a fair computational comparison.
The study addresses four research questions: (RQ1) how accurately an NPE recovers and across signal-to-noise ratios; (RQ2) how posterior calibration changes as the signal-to-noise ratio decreases or the test parameters move away from the training distribution; (RQ3) whether a physics-guided representation improves recovery or calibration relative to an otherwise identical unconstrained estimator; and (RQ4) what trade-off exists between accuracy, calibration and computational cost. The corresponding testable hypotheses are stated in Section 4.5.
The remainder of the paper is organized as follows. Section 2 summarizes the waveform physics and derives the identifiability properties of the mass parameters. Section 3 presents the statistical framework. Section 4 describes the simulation design, baselines, ablation and hypotheses, and Section 5 defines the evaluation metrics. Section 6 sets out the analysis protocol and the analytic consistency checks. Section 7, Section 8 and Section 9 discuss the implications, limitations and conclusions.
2. Theoretical Framework
2.1. Mass Parameterization
Let and denote the component masses of the binary, with . The total mass, mass ratio and symmetric mass ratio are
The combination that governs the leading-order inspiral is the chirp mass,
Equation (2) is invertible on , so the component masses follow uniquely from :
These relations motivate the choice of as the primary inference parameters. Posteriors for and are obtained by pushing posterior samples through Eq. (3), which preserves the correlation structure instead of treating the derived masses as independent point estimates.
2.2. Leading-Order Inspiral Dynamics
In the quadrupole approximation, balancing the gravitational-wave luminosity against the Newtonian orbital binding energy [3,25] gives the evolution of the gravitational-wave frequency (twice the orbital frequency):
Integrating Eq. (4) yields the time remaining until coalescence,
where is the coalescence time. Equations (4) and (5) show that, at this order, the chirp mass alone controls the rate at which the observed frequency sweeps upward. For the mass range considered here (Table 1), lies between approximately 3 s and 11 s, which fixes the minimum segment duration. The inspiral description is terminated at the innermost-stable-circular-orbit frequency of a test particle around a Schwarzschild black hole of mass ,
which ranges from about 293 Hz for to about 49 Hz for .
2.3. Frequency-Domain Waveform
The frequency-domain signal is computed in the stationary-phase approximation [26,27]:
where is the Heaviside step function. For an optimally oriented source at luminosity distance , with collecting the detector-response and inclination factors (), the leading-order amplitude is
The phase is written as a post-Newtonian (PN) series in the orbital velocity parameter [25,27]:
where is the coalescence phase and is the PN truncation order ( PN). For non-spinning binaries the coefficients up to second PN order are
Retaining only and using recovers the Newtonian phase
This waveform is intentionally simplified: it neglects spins, higher harmonics, the merger and the ringdown, and PN terms beyond the chosen order. Conclusions therefore apply to the selected waveform family and simulated data domain, and do not automatically generalize to real detector observations.
2.4. Identifiability of the Mass Ratio
Equations (8) and (12) reveal a property that is central to the experimental design. At Newtonian order, both the amplitude and the phase depend on exclusively through . Consequently, for any two parameter vectors with equal , and ,
apart from the weak and unphysical dependence introduced by the -dependent cutoff . In other words, the mass ratio is not identifiable from a Newtonian-order waveform, and its conditional posterior must equal its conditional prior. Information on (through ) enters first at 1PN order via , and is reinforced by the 2PN term . This yields two complementary experimental regimes. The 0PN regime provides an exact null test: a calibrated estimator must return the prior for , and any apparent constraint signals overfitting, information leakage through the cutoff, or miscalibration. The 2PN regime, which is adopted as the default, makes measurable and allows RQ1–RQ4 to be addressed for both parameters. To remove the cutoff artifact in the null test, is fixed at the smallest over the prior support in that experiment.
3. Statistical Inference Framework
3.1. Observation Model and Noise-Weighted Inner Product
The simulated frequency-domain data are
where is a realization of zero-mean, stationary Gaussian noise with one-sided power spectral density (PSD) :
Initial experiments use white noise (); a subsequent experiment introduces coloured noise with a published detector PSD. The noise-weighted inner product [5,6] is
which, for data sampled on a uniform grid with , is evaluated as
With the discrete convention of Eq. (17), the real and imaginary parts of are independent with variance . The same normalization is applied consistently to the waveform, the PSD, the noise generator and the likelihood. The log-likelihood is then
The optimal signal-to-noise ratio is . To place each injection at a prescribed value , the template is rescaled as
which is equivalent to adjusting . Under this convention the amplitude carries no information on , and the mass information is contained in the phase evolution, Eq. (9).
3.2. Bayesian Posterior and Priors
The posterior follows from Bayes’ theorem,
Writing with nuisance parameters , the target is the marginal posterior
Priors must be stated in a specific parameterization because they are not invariant under reparameterization. If the component masses are drawn uniformly on the domain of Table 1 subject to , the induced prior on the inference parameters is obtained from the Jacobian of Eq. (3),
The same prior is used for training-set generation, for the Bayesian reference analysis and for the coverage tests; a sampling scheme uniform in is considered as an explicit alternative in the distribution-shift experiments.
3.3. Fisher-Information Benchmark
In the high signal-to-noise limit the posterior is approximately Gaussian with covariance given by the inverse Fisher information matrix [5,28],
where the inequality is the Cramér–Rao bound for unbiased estimators. Because the signal-to-noise ratio is imposed through Eq. (19), with , and therefore
Equation (24) provides a quantitative, model-independent prediction for hypothesis H1 and an analytic reference against which the widths of both the neural and the sampled posteriors can be compared. Deviations are expected at , where the linear-signal approximation underlying the Fisher matrix is least accurate [28].
3.4. Neural Posterior Estimation
NPE trains a conditional density estimator , with trainable parameters , to approximate the posterior given a representation of the data. Training minimizes the expected negative log-density over the joint distribution of simulations,
which equals, up to a constant, the expected Kullback–Leibler divergence from the true posterior to the approximation; its minimizer therefore recovers in the limit of sufficient capacity and data [11,12]. The estimator is a conditional normalizing flow [13,14], in which an invertible map transforms the parameters into a standard-normal latent variable :
The network input is the whitened frequency series
whose real and imaginary parts have unit variance under noise alone, so that the network operates on the same statistical scale as the likelihood of Eq. (18). Architecture and hyperparameters are selected on the validation set only, on the basis of validation loss, numerical stability and sampling cost.
3.5. Operational Definition of “Physics-Guided”
Training a network on physically generated signals does not, by itself, make it physics-informed. In this study, an estimator is called physics-guided if it satisfies the following explicit and testable conditions: (a) it infers the physically natural parameters of Eq. (2); (b) its output distribution has support only on the physically valid domain, enforced through the bijective reparameterization
with the corresponding change-of-variables correction included in the density; (c) it is trained with the physically valid prior of Eq. (22); and (d) its inputs are whitened with the same PSD as the likelihood, Eq. (27). Any additional architectural constraint (for example, conditioning on frequency features derived from Eq. (4)) is treated as a separate ablation level and tested independently (Section 4.4).
4. Methodology
4.1. Research Design
The study adopts a computational, simulation-based design in which synthetic signals are generated from known source parameters, analysed by competing inference methods and evaluated against the generating parameters. The workflow comprises five stages:
- Sample physically valid parameters from the explicitly stated prior, Eq. (22).
- Generate TaylorF2 waveforms (Eqs. (7)–(11)) and validate them against an independent implementation and the analytic limits of Section 2.
- Construct training, validation and test sets with controlled noise realizations and prescribed signal-to-noise ratios, Eq. (19).
- Train the neural posterior estimator and implement matched baseline methods.
- Evaluate parameter recovery, posterior calibration, robustness and computational cost.
4.2. Simulation Parameters
The simulation settings are summarized in Table 1. They are starting values for the study, not experimentally established optima. The dataset is split into training, validation and test subsets at the level of independent parameter draws, before any noise realizations or augmented copies are generated, so that near-duplicate waveforms cannot leak between subsets. All random seeds are recorded.
4.3. Baseline Methods
Baseline A — waveform optimization. Parameters are estimated by maximizing the likelihood of Eq. (18) (equivalently, minimizing the noise-weighted residual) with a multi-start optimizer. This yields a maximum-likelihood point estimate but no calibrated posterior.
Baseline B — Bayesian reference. Posterior samples are drawn from Eq. (20) with a nested sampler in Bilby [9], using a custom likelihood that implements exactly the waveform, prior and noise model of the neural experiment. Sampler convergence is verified by repeated runs with different seeds.
Baseline C — MLP regressor. A multilayer perceptron with the same input as the NPE is trained with a mean-squared-error loss to output point estimates of .
Proposed model — NPE. A conditional normalizing flow, Eq. (26), trained with Eq. (25).
All methods are evaluated on identical test signals with identical priors and likelihood assumptions. Any residual difference in assumptions is reported explicitly rather than attributed to the algorithm.
4.4. Physics-Guided Ablation
To isolate the contribution of the physics-guided components (RQ3), three model variants are trained with the same data, data splits, optimization budget and evaluation cases (Table 2). Each variant is trained with at least five independent initializations, and differences are reported with confidence intervals across runs.
4.5. Hypotheses
The following hypotheses are proposed for empirical testing; none is assumed to be true a priori.
- H1. Parameter-recovery error and posterior width increase as decreases, following approximately the scaling of Eq. (24) for .
- H2. A calibrated posterior estimator provides more informative uncertainty estimates than a point-estimation model alone, as measured by coverage and interval width.
- H3. The physics-guided variant M1 improves robustness under noise and distribution shift relative to the otherwise comparable unconstrained variant M0.
- H4. After accounting for simulation and training costs, amortized neural inference reduces the total inference cost relative to repeated Bayesian sampling once the number of analysed events exceeds the break-even value of Eq. (33).
5. Evaluation Metrics
5.1. Point-Estimation Error
For a test set of injections with true values and point estimates (the posterior median for probabilistic methods),
These metrics are computed separately for , , and , because accurate chirp-mass recovery does not imply accurate component-mass recovery.
5.2. Bias and Posterior Calibration
The signed bias is
Calibration is assessed with the empirical coverage of central credible intervals at nominal level ,
and with the posterior-CDF statistic evaluated at the true value,
5.3. Computational Cost
We report training time and hardware configuration, per-event inference time, the number of likelihood evaluations (where applicable), peak memory use and the total cost over the evaluated set. Writing and for the one-time simulation and training costs, and and for the per-event costs of the reference sampler and the neural estimator, the amortization break-even number of events is
5.4. Robustness Tests
- Noise-level variation across each prescribed , including training at one and testing at another.
- Parameter-distribution shift near and beyond the edges of the training prior, and change of prior parameterization (Section 3.2).
- Noise-model shift (white to coloured noise), after the white-noise baseline has been validated.
- Waveform-order shift: training on 2PN signals and testing on signals that include an additional PN term, as a controlled proxy for waveform systematics.
- Repeated training runs to quantify sensitivity to initialization and stochastic optimization.
6. Analysis Protocol and Expected Outcomes
This section specifies the analysis protocol. No numerical performance claims are made before the simulations have been executed; Table 3 defines the quantities to be reported.
Waveform and likelihood validation. Before any learning, the simulator is checked against three analytic properties: (i) the measured equals after Eq. (19); (ii) the mean of over noise realizations equals the number of complex frequency bins times two, confirming the normalization of Eq. (17); and (iii) the frequency evolution of the Newtonian limit reproduces Eqs. (4) and (5).
Parameter recovery (RQ1). MAE, relative error, RMSE and signed bias are reported for , , and , with bootstrap confidence intervals over test injections.
Calibration and null test (RQ2). P–P plots and representative posteriors are shown for each , including broad and prior-boundary cases. In the 0PN experiment the marginal posterior of is compared with its prior using the Kullback–Leibler divergence; by Eq. (13), a calibrated estimator should give a divergence consistent with zero.
Robustness and Fisher benchmark (RQ2–RQ3). Posterior widths are plotted against together with the Fisher prediction of Eq. (24). Degradation under each shift of Section 5.4 is reported, and failure cases are presented explicitly.
Computational comparison (RQ4). Inference latency and total cost are reported for a documented hardware and software configuration, separating one-time from per-event costs and reporting of Eq. (33).
7. Discussion
The proposed design separates three questions that are often conflated in machine-learning applications to physical inference: whether a model recovers the correct parameter values, whether its uncertainty estimates are statistically reliable, and whether it offers a genuine computational advantage. A model can attain a low average error while producing intervals that are too narrow, and therefore report unjustified confidence [23]. Likewise, a model that performs well on randomly sampled test examples may fail on parameter combinations that are rare or absent in its training distribution.
The identifiability analysis of Section 2.4 gives the framework a feature that is rarely available in applied studies: an exact, physics-derived expectation for one marginal posterior. Because the Newtonian waveform is invariant under changes of at fixed , the correct answer in the 0PN experiment is known without running a sampler. The Fisher scaling of Eq. (24) plays a similar role for the posterior widths. Together, these analytic anchors allow failures of calibration to be distinguished from genuine information content.
The simplified waveform is appropriate for methodological validation but introduces an important limitation: the estimator learns the inverse mapping of the chosen waveform and noise model. Discrepancies between that model and real signals propagate into the inferred parameters. Higher-order PN corrections, spins, inspiral–merger–ringdown models and realistic detector noise are therefore necessary before conclusions can be transferred to observational data.
Novelty cannot be claimed merely from applying a neural network to binary black hole parameter estimation, which has been demonstrated extensively [15,16,17,18]. The intended contribution lies in the controlled comparison under matched assumptions, the explicit evaluation of calibration and distribution shift with analytic anchors, and the separately tested physics-guided components. If the proposed method does not outperform the baselines, the result remains informative: it would indicate that the physical constraints provide limited benefit in this regime, or that the simplified waveform is insufficient to discriminate between methods.
8. Limitations
The study has five principal limitations. First, the TaylorF2 inspiral approximation is not a complete inspiral–merger–ringdown model, and for the heaviest systems considered the inspiral band above is short. Second, the initial noise model is simplified relative to real detector noise, which is non-stationary and contains non-Gaussian transients. Third, only a restricted subset of source parameters is inferred, and extrinsic parameters are either fixed or absorbed by the signal-to-noise normalization. Fourth, posterior calibration is assessed only with respect to the simulated parameter and noise distributions. Fifth, computational comparisons depend on hardware, implementation and the number of inference tasks. These limitations define the scope of the investigation; they do not invalidate the controlled experiment, provided the conclusions remain within its stated domain.
9. Conclusions
We have presented a reproducible framework for investigating physics-guided neural posterior estimation of the chirp mass and mass ratio of non-spinning binary black hole inspirals. The framework fixes the waveform, noise, prior and inner-product conventions so that neural and likelihood-based inference can be compared under identical assumptions. We have shown that the Newtonian-order waveform carries no information on the mass ratio, and have turned this degeneracy into an exact null test of posterior calibration; Fisher-information bounds supply a complementary analytic benchmark for the expected scaling of the uncertainties. The evaluation protocol emphasizes parameter recovery, calibration, robustness and amortized computational cost, and requires the contribution of physics-guided components to be demonstrated against matched baselines rather than assumed.
The next stage is to implement and validate the simulator, generate the synthetic datasets, execute the baseline and ablation experiments and report the measured results. Extension to higher-order and spin-dependent waveforms, multi-detector networks and realistic detector noise will be required before drawing conclusions about performance on observational gravitational-wave data.
References
- B. P. Abbott et al. (LIGO Scientific Collaboration and Virgo Collaboration); et al. Observation of gravitational waves from a binary black hole merger. Phys. Rev. Lett. 2016, 116, 061102. [Google Scholar] [CrossRef] [PubMed]
- Abbott, R.; et al. (LIGO Scientific Collaboration; Virgo Collaboration; and KAGRA Collaboration; et al. GWTC-3: Compact binary coalescences observed by LIGO and Virgo during the second part of the third observing run. Phys. Rev. X 2023, 13, 041039. [Google Scholar] [CrossRef]
- Peters, P.C.; Mathews, J. Gravitational radiation from point masses in a Keplerian orbit. Phys. Rev. 1963, 131, 435. [Google Scholar] [CrossRef]
- Peters, P.C. Gravitational radiation and the motion of two point masses. Phys. Rev. 1964, 136, B1224. [Google Scholar] [CrossRef]
- Cutler, C.; Flanagan, É.E. Gravitational waves from merging compact binaries: How accurately can one extract the binary’s parameters from the inspiral waveform? Phys. Rev. D. 1994, 49, 2658. [Google Scholar] [CrossRef] [PubMed]
- Finn, L.S. Detection, measurement, and gravitational radiation. Phys. Rev. D. 1992, 46, 5236. [Google Scholar] [CrossRef] [PubMed]
- Thrane, E.; Talbot, C. An introduction to Bayesian inference in gravitational-wave astronomy: Parameter estimation, model selection, and hierarchical models. Publ. Astron. Soc. Aust. 2019, 36, e010. [Google Scholar] [CrossRef]
- Veitch, J.; et al. Parameter estimation for compact binaries with ground-based gravitational-wave observations using the LALInference software library. Phys. Rev. D. 2015, 91, 042003. [Google Scholar] [CrossRef]
- Ashton, G.; et al. BILBY: A user-friendly Bayesian inference library for gravitational-wave astronomy. Astrophys. J. Suppl. Ser. 241 2019, 27. [Google Scholar] [CrossRef]
- Cuoco, E.; et al. Enhancing gravitational-wave science with machine learning. Mach. Learn. Sci. Technol. 2021, 2, 011002. [Google Scholar] [CrossRef]
- Cranmer, K.; Brehmer, J.; Louppe, G. The frontier of simulation-based inference. Proc. Natl. Acad. Sci. U.S.A. 2020, 117, 30055. [Google Scholar] [CrossRef] [PubMed]
- Papamakarios, G.; Murray, I. Fast ε-free inference of simulation models with Bayesian conditional density estimation. Adv. Neural Inf. Process. Syst. 2016, arXiv:1605.06376. [Google Scholar] [CrossRef]
- Papamakarios, G.; Nalisnick, E.; Rezende, D.J.; Mohamed, S.; Lakshminarayanan, B. Normalizing flows for probabilistic modeling and inference. J. Mach. Learn. Res. 2021, 22, 1. [Google Scholar]
- Durkan, C.; Bekasov, A.; Murray, I.; Papamakarios, G. Neural spline flows. Adv. Neural Inf. Process. Syst. 32 2019, arXiv:1906.04032. [Google Scholar] [CrossRef]
- Gabbard, H.; Messenger, C.; Heng, I.S.; Tonolini, F.; Murray-Smith, R. Bayesian parameter estimation using conditional variational autoencoders for gravitational-wave astronomy. Nat. Phys. 2022, 18, 112. [Google Scholar] [CrossRef]
- Green, S.R.; Gair, J. Complete parameter inference for GW150914 using deep learning. Mach. Learn. Sci. Technol. 2021, 2, 03LT01. [Google Scholar] [CrossRef]
- Dax, M.; Green, S.R.; Gair, J.; Macke, J.H.; Buonanno, A.; Schölkopf, B. Real-time gravitational wave science with neural posterior estimation. Phys. Rev. Lett. 2021, 127, 241103. [Google Scholar] [CrossRef] [PubMed]
- Dax, M.; Green, S.R.; Gair, J.; Pürrer, M.; Wildberger, J.; Macke, J.H.; Buonanno, A.; Schölkopf, B. Neural importance sampling for rapid and reliable gravitational-wave inference. Phys. Rev. Lett. 2023, 130, 171403. [Google Scholar] [CrossRef] [PubMed]
- Andrés-Carcasona, M.; Martínez, M.; Mir, L.M. Fast Bayesian gravitational wave parameter estimation using convolutional neural networks. Mon. Not. R. Astron. Soc. 2024, 527, 2887. [Google Scholar] [CrossRef]
- Raymond, V.; Al-Shammari, S.; Göttel, A. Simulation-based inference for gravitational-waves from intermediate-mass binary black holes in real noise. Mon. Not. R. Astron. Soc. 2025, 542, 1103. [Google Scholar] [CrossRef]
- Negri, L.; Samajdar, A. Neural likelihood estimators for flexible gravitational wave data analysis. Mon. Not. R. Astron. Soc. 2026. [Google Scholar] [CrossRef]
- Emma, M.; Ashton, G. Residual neural likelihood estimation and its application to gravitational-wave astronomy. Phys. Rev. D. 2026. [Google Scholar] [CrossRef]
- Hermans, J.; Delaunoy, A.; Rozet, F.; Wehenkel, A.; Begy, V.; Louppe, G. A trust crisis in simulation-based inference? Your posterior approximations can be unfaithful. Trans. Mach. Learn. Res. 2022, arXiv:2110.06581. [Google Scholar] [CrossRef]
- Karniadakis, G.E.; Kevrekidis, I.G.; Lu, L.; Perdikaris, P.; Wang, S.; Yang, L. Physics-informed machine learning. Nat. Rev. Phys. 2021, 3, 422. [Google Scholar] [CrossRef]
- Blanchet, L. Gravitational radiation from post-Newtonian sources and inspiralling compact binaries. Living Rev. Relativ. 2014, 17, 2. [Google Scholar] [CrossRef] [PubMed]
- Sathyaprakash, B.S.; Schutz, B.F. Physics, astrophysics and cosmology with gravitational waves. Living Rev. Relativ. 2009, 12, 2. [Google Scholar] [CrossRef] [PubMed]
- Buonanno, A.; Iyer, B.R.; Ochsner, E.; Pan, Y.; Sathyaprakash, B.S. Comparison of post-Newtonian templates for compact binary inspiral signals in gravitational-wave detectors. Phys. Rev. D. 2009, 80, 084043. [Google Scholar] [CrossRef]
- Vallisneri, M. Use and abuse of the Fisher information matrix in the assessment of gravitational-wave parameter-estimation prospects. Phys. Rev. D. 2008, 77, 042001. [Google Scholar] [CrossRef]
- Talts, S.; Betancourt, M.; Simpson, D.; Vehtari, A.; Gelman, A. Validating Bayesian inference algorithms with simulation-based calibration. arXiv 2018, arXiv:1804.06788. [Google Scholar]
Table 1.
Simulation settings for the initial experiments.
| Quantity | Setting |
|---|---|
| Primary mass, | – |
| Secondary mass, | –with |
| Mass ratio, | (implied by the mass domain) |
| Chirp mass, | –(implied) |
| Prior | Uniform in Eq. (22); uniform in as shift test |
| Nuisance parameters | |
| Spin and orbit | Non-spinning, quasi-circular |
| Waveform | TaylorF2, Eqs. (7)–(11); 2PN (default) and 0PN (null test) |
| Frequency band | to Eq. (6) |
| Segment duration | () |
| Noise | Noise-free validation; white Gaussian; coloured Gaussian (extension) |
| Optimal SNR, | |
| Dataset size | –draws, subject to convergence |
Table 2.
Ablation design for the physics-guided components.
| Variant | Description |
|---|---|
| M0 — unconstrained | Standardized (not whitened) inputs; direct outputs unbounded support |
| M1 — physics-guided | Whitened inputs, Eq. (27); outputs via Eq. (28); prior of Eq. (22) |
| M2 — physics-constrained | M1 plus an explicit physical feature or constraint derived from Eqs. (4)–(9) (where feasible) |
Table 3.
Planned comparison of methods. Entries are placeholders and must not be interpreted as experimental findings.
Table 3.
Planned comparison of methods. Entries are placeholders and must not be interpreted as experimental findings.
| Metric | NPE (M1) | MLP baseline | Bayesian reference |
|---|---|---|---|
| MAE | To be measured | To be measured | Posterior median |
| MAE | To be measured | To be measured | Posterior median |
| 90% interval coverage | To be measured | Not available | To be measured |
| 0PN null test (KL to prior) | To be measured | Not applicable | To be measured |
| Median inference time | To be measured | To be measured | To be measured |
| Break-even | To be measured | — | Reference |
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
Copyright: This open access article is published under a Creative Commons CC BY 4.0 license, which permit the free download, distribution, and reuse, provided that the author and preprint are cited in any reuse.