Preprint
Article

This version is not peer-reviewed.

Digital Recordings of Centric Relation Using Conventional and Digital Techniques: Patient-Reported Outcomes Measurement (PROMs)

Submitted:

10 February 2026

Posted:

11 February 2026

You are already at the latest version

Abstract
Centric relation (CR) is a reproducible mandibular reference position that plays a critical role in complex prosthodontic cases. With the advent of digital jaw tracking devices, CR can now be recorded with greater precision through fully digital methods. This study aimed to compare pati-ent-reported outcome measures (PROMs) for the recording of CR determined with conventional and digital techniques. Patients requiring occlusal rehabilitation due to bilateral loss of posterior support in the maxilla were included. Two different jaw relation recording techniques were ap-plied: conventionally determined CR and digitally determined CR. The former was determined using bimanual manipulation, while the latter through multiple mandibular closure recordings performed with an anterior plateau using a jaw-tracking device. PROMs were assessed using Visual Analog Scale (VASs) to evaluate patient experience during jaw relation recording and comfort during restoration try-in. The recording time for both techniques was documented, and the correlation between recording time and VAS scores related to the recording procedure was analyzed. Statistical analyses were performed using the Wilcoxon signed-rank test and Spear-man correlation analysis (α=0.05). Twelve patients were included. No statistically significant difference was found between the two methods in VAS scores assessing patient-reported com-fort and experience. Recording time was significantly shorter for the recording of conventionally determined CR (p=0.002). No statistically significant correlation was found between recording time and patient-reported experience for both techniques (p>0.05). Despite the need for clinician experience and patient compliance, PROMs for digitally determined CR were comparable to those of conventionally determined CR.
Keywords: 
;  ;  ;  ;  
Copyright: This open access article is published under a Creative Commons CC BY 4.0 license, which permit the free download, distribution, and reuse, provided that the author and preprint are cited in any reuse.
Prerpints.org logo

Preprints.org is a free preprint server supported by MDPI in Basel, Switzerland.

Subscribe

Disclaimer

Terms of Use

Privacy Policy

Privacy Settings

© 2026 MDPI (Basel, Switzerland) unless otherwise stated