Submitted:
11 October 2023
Posted:
12 October 2023
You are already at the latest version
Abstract
Keywords:
1. Introduction
2. Materials and methods
2.1. Sample Eligibility
2.2. Clinical Diagnosis for AD
2.3. Exclusion Criteria
2.4. MRI Acquisition Protocol
2.5. Volumetry Procedure
2.6. Gold Standard for Significant MTA
2.7. Statistical Analyses
3. Results
3.1. Baseline Characteristics of Study Sample
3.2. Comparing Detecting Performance for the Significant MTA
3.3. Correlation of Mean Volume with Scheltens’ Scale
3.4. Sub-analysis for Mean Volume Comparison and Inter-method Reliability
4. Discussion
5. Conclusions
Supplementary Materials
Author Contributions
Funding
Institutional Review Board Statement
Informed Consent Statement
Data Availability Statement
Acknowledgments
Conflicts of Interest
Appendix
Appendix E1. Calculation of Sample Size
Appendix E2. Volumetry Process Steps of NeuroQuant® and Aqua®
Appendix E3. Mean Volume Comparison and Inter-method Reliability
References
- Matthews, K.A.; Xu, W.; Gaglioti, A.H.; Holt, J.B.; Croft, J.B.; Mack, D.; McGuire, L.C. Racial and ethnic estimates of Alzheimer's disease and related dementias in the United States (2015-2060) in adults aged >/=65 years. Alzheimers Dement 2019, 15, 17-24, doi:10.1016/j.jalz.2018.06.3063. [CrossRef]
- Li, X.; Feng, X.; Sun, X.; Hou, N.; Han, F.; Liu, Y. Global, regional, and national burden of Alzheimer's disease and other dementias, 1990–2019. Frontiers in Aging Neuroscience 2022, 14, 937486. [CrossRef]
- Baek, M.S.; Kim, H.-K.; Han, K.; Kwon, H.-S.; Na, H.K.; Lyoo, C.H.; Cho, H. Annual trends in the incidence and prevalence of Alzheimer's disease in South Korea: a nationwide cohort study. Frontiers in Neurology 2022, 13, 883549. [CrossRef]
- Giorgio, A.; De Stefano, N. Clinical use of brain volumetry. Journal of Magnetic Resonance Imaging 2013, 37, 1-14. [CrossRef]
- Sarazin, M.; de Souza, L.C.; Lehéricy, S.; Dubois, B. Clinical and research diagnostic criteria for Alzheimer's disease. Neuroimaging Clin N Am 2012, 22, 23-32,viii, doi:10.1016/j.nic.2011.11.004. [CrossRef]
- McKhann, G.M.; Knopman, D.S.; Chertkow, H.; Hyman, B.T.; Jack, C.R., Jr.; Kawas, C.H.; Klunk, W.E.; Koroshetz, W.J.; Manly, J.J.; Mayeux, R.; et al. The diagnosis of dementia due to Alzheimer's disease: recommendations from the National Institute on Aging-Alzheimer's Association workgroups on diagnostic guidelines for Alzheimer's disease. Alzheimers Dement 2011, 7, 263-269, doi:10.1016/j.jalz.2011.03.005. [CrossRef]
- Scheltens, P.; Leys, D.; Barkhof, F.; Huglo, D.; Weinstein, H.C.; Vermersch, P.; Kuiper, M.; Steinling, M.; Wolters, E.C.; Valk, J. Atrophy of medial temporal lobes on MRI in "probable" Alzheimer's disease and normal ageing: diagnostic value and neuropsychological correlates. J Neurol Neurosurg Psychiatry 1992, 55, 967-972, doi:10.1136/jnnp.55.10.967. [CrossRef]
- Scheltens, P.; Pasquier, F.; Weerts, J.G.; Barkhof, F.; Leys, D. Qualitative assessment of cerebral atrophy on MRI: inter- and intra-observer reproducibility in dementia and normal aging. Eur Neurol 1997, 37, 95-99, doi:10.1159/000117417. [CrossRef]
- Sarria-Estrada, S.; Acevedo, C.; Mitjana, R.; Frascheri, L.; Siurana, S.; Auger, C.; Rovira, A. Reproducibility of qualitative assessments of temporal lobe atrophy in MRI studies. Radiologia 2015, 57, 225-228, doi:10.1016/j.rx.2014.04.002. [CrossRef]
- Scheltens, P.; Launer, L.J.; Barkhof, F.; Weinstein, H.C.; van Gool, W.A. Visual assessment of medial temporal lobe atrophy on magnetic resonance imaging: interobserver reliability. J Neurol 1995, 242, 557-560, doi:10.1007/bf00868807. [CrossRef]
- Pereira, J.; Cavallin, L.; Spulber, G.; Aguilar, C.; Mecocci, P.; Vellas, B.; Tsolaki, M.; Kłoszewska, I.; Soininen, H.; Spenger, C. Influence of age, disease onset and ApoE4 on visual medial temporal lobe atrophy cut-offs. Journal of internal medicine 2014, 275, 317-330. [CrossRef]
- Ten Kate, M.; Barkhof, F.; Boccardi, M.; Visser, P.J.; Jack, C.R., Jr.; Lovblad, K.O.; Frisoni, G.B.; Scheltens, P. Clinical validity of medial temporal atrophy as a biomarker for Alzheimer's disease in the context of a structured 5-phase development framework. Neurobiol Aging 2017, 52, 167-182.e161, doi:10.1016/j.neurobiolaging.2016.05.024. [CrossRef]
- Lee, J.Y.; Park, J.E.; Chung, M.S.; Oh, S.W.; Moon, W.J. [Expert Opinions and Recommendations for the Clinical Use of Quantitative Analysis Software for MRI-Based Brain Volumetry]. Taehan Yongsang Uihakhoe Chi 2021, 82, 1124-1139, doi:10.3348/jksr.2020.0174. [CrossRef]
- Wang, C.; Beadnall, H.N.; Hatton, S.N.; Bader, G.; Tomic, D.; Silva, D.G.; Barnett, M.H. Automated brain volumetrics in multiple sclerosis: a step closer to clinical application. J Neurol Neurosurg Psychiatry 2016, 87, 754-757, doi:10.1136/jnnp-2015-312304. [CrossRef]
- Min, J.; Moon, W.J.; Jeon, J.Y.; Choi, J.W.; Moon, Y.S.; Han, S.H. Diagnostic Efficacy of Structural MRI in Patients With Mild-to-Moderate Alzheimer Disease: Automated Volumetric Assessment Versus Visual Assessment. AJR Am J Roentgenol 2017, 208, 617-623, doi:10.2214/ajr.16.16894. [CrossRef]
- Choi, Y.Y.; Lee, J.J.; Choi, K.Y.; Choi, U.S.; Seo, E.H.; Choo, I.H.; Kim, H.; Song, M.K.; Choi, S.M.; Cho, S.H.; et al. Multi-Racial Normative Data for Lobar and Subcortical Brain Volumes in Old Age: Korean and Caucasian Norms May Be Incompatible With Each Other(†). Front Aging Neurosci 2021, 13, 675016, doi:10.3389/fnagi.2021.675016. [CrossRef]
- Lee, J.Y.; Oh, S.W.; Chung, M.S.; Park, J.E.; Moon, Y.; Jeon, H.J.; Moon, W.J. Clinically Available Software for Automatic Brain Volumetry: Comparisons of Volume Measurements and Validation of Intermethod Reliability. Korean J Radiol 2021, 22, 405-414, doi:10.3348/kjr.2020.0518. [CrossRef]
- Vahia, V.N. Diagnostic and statistical manual of mental disorders 5: A quick glance. Indian Journal of Psychiatry 2013, 55. [CrossRef]
- Wahlund, L.-O.; Julin, P.; Johansson, S.-E.; Scheltens, P. Visual rating and volumetry of the medial temporal lobe on magnetic resonance imaging in dementia: a comparative study. Journal of Neurology, Neurosurgery & Psychiatry 2000, 69, 630-635. [CrossRef]
- Brown, D.; Volkers, P.; Day, S. An introductory note to CHMP guidelines: choice of the non-inferiority margin and data monitoring committees. Statistics in medicine 2006, 25, 1623-1627. [CrossRef]
- Lansdorp-Vogelaar, I.; Jagsi, R.; Jayasekera, J.; Stout, N.K.; Mitchell, S.A.; Feuer, E.J. Evidence-based sizing of non-inferiority trials using decision models. BMC Medical Research Methodology 2019, 19, 3, doi:10.1186/s12874-018-0643-2. [CrossRef]
- Persson, K.; Barca, M.L.; Cavallin, L.; Brækhus, A.; Knapskog, A.-B.; Selbæk, G.; Engedal, K. Comparison of automated volumetry of the hippocampus using NeuroQuant® and visual assessment of the medial temporal lobe in Alzheimer’s disease. Acta Radiologica 2018, 59, 997-1001. [CrossRef]
- Persson, K.; Barca, M.L.; Cavallin, L.; Brækhus, A.; Knapskog, A.B.; Selbæk, G.; Engedal, K. Comparison of automated volumetry of the hippocampus using NeuroQuant® and visual assessment of the medial temporal lobe in Alzheimer's disease. Acta Radiol 2018, 59, 997-1001, doi:10.1177/0284185117743778. [CrossRef]
- Molinder, A.; Ziegelitz, D.; Maier, S.E.; Eckerström, C. Validity and reliability of the medial temporal lobe atrophy scale in a memory clinic population. BMC Neurology 2021, 21, 289, doi:10.1186/s12883-021-02325-2. [CrossRef]
- Ross, D.E.; Ochs, A.L.; Seabaugh, J.M.; Shrader, C.R. Man versus machine: comparison of radiologists' interpretations and NeuroQuant® volumetric analyses of brain MRIs in patients with traumatic brain injury. J Neuropsychiatry Clin Neurosci 2013, 25, 32-39, doi:10.1176/appi.neuropsych.11120377. [CrossRef]
- Ross, D.E.; Ochs, A.L.; Tate, D.F.; Tokac, U.; Seabaugh, J.; Abildskov, T.J.; Bigler, E.D. High correlations between MRI brain volume measurements based on NeuroQuant® and FreeSurfer. Psychiatry Research: Neuroimaging 2018, 278, 69-76, doi:https://doi.org/10.1016/j.pscychresns.2018.05.007. [CrossRef]
- Kim, R.E.; Lee, M.; Kang, D.W.; Wang, S.-M.; Kim, N.-Y.; Lee, M.K.; Lim, H.K.; Kim, D. Deep learning-based segmentation to establish East Asian normative volumes using multisite structural MRI. Diagnostics 2020, 11, 13. [CrossRef]
- Boccardi, M.; Ganzola, R.; Bocchetta, M.; Pievani, M.; Redolfi, A.; Bartzokis, G.; Camicioli, R.; Csernansky, J.G.; De Leon, M.J.; deToledo-Morrell, L. Survey of protocols for the manual segmentation of the hippocampus: preparatory steps towards a joint EADC-ADNI harmonized protocol. Journal of Alzheimer's disease 2011, 26, 61-75. [CrossRef]
- Zaki, L.A.; Vernooij, M.W.; Smits, M.; Tolman, C.; Papma, J.M.; Visser, J.J.; Steketee, R.M. Comparing two artificial intelligence software packages for normative brain volumetry in memory clinic imaging. Neuroradiology 2022, 64, 1359-1366. [CrossRef]
- Song, H.; Lee, S.A.; Jo, S.W.; Chang, S.-K.; Lim, Y.; Yoo, Y.S.; Kim, J.H.; Choi, S.H.; Sohn, C.-H. Agreement and Reliability between Clinically Available Software Programs in Measuring Volumes and Normative Percentiles of Segmented Brain Regions. Korean Journal of Radiology 2022, 23, 959. [CrossRef]


| Characteristics | Overall | Non-AD | AD |
| Number of participants | 127 | 54 | 73 |
| Age (y)* | 78.57 ± 7.01 | 74.53 ± 7.60 | 80.25 ± 6.52 |
| Sex | |||
| Male | 38 | 21 | 17 |
| Female | 89 | 33 | 56 |
| K-MMSE score* | 18.24 ± 6.48 | 19.63 ± 5.93 | 17.32 ± 6.71 |
| CDR score* | 6.68 ± 6.81 | 5.09 ± 4.40 | 7.85 ± 7.96 |
| Statistical values | Overall | Non-AD | AD |
| Accuracy (%, 95% CI) | |||
| NeuroQuant® | 83.5 (77.2-90.0) | 79.6 (78.9-90.4) | 84.9 (76.7-93.1) |
| Aqua® | 87.4 (81.8-93.0) | 88.9 (80.5-97.3) | 83.6 (75.1-92.1) |
| p-value | 0.108 | 0.187 | 0.820 |
| Sensitivity (%, 95% CI) | |||
| NeuroQuant® | 83.1 (76.7-89.4) | 72.2 (60.3-84.2) | 87.8 (80.3-95.3) |
| Aqua® | 78.0 (71.0-85.0) | 77.2 (60.3-84.2) | 80.5 (73.5-91.0) |
| p-value | 0.642 | 0.999 | 0.545 |
| Specificity (%, 95% CI) | |||
| NeuroQuant® | 83.8 (77.6-90.1) | 83.3 (73.4-93.3) | 84.4 (76.1-92.7) |
| Aqua® | 95.6 (92.1-99.1) | 97.2 (92.8-100) | 93.8 (87.0-98.8) |
| p-value | 0.048 * | 0.112 | 0.423 |
| Kendall's τ | Overall | Non-AD | AD |
| NeuroQuant® | - 0.15 * | - 0.12 | - 0.20 * |
| Aqua® | - 0.44 * | - 0.35 * | - 0.49 * |
| p-value | <0.001 † | <0.001 † | <0.001 † |
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).