Preprint Article Version 1 Preserved in Portico This version is not peer-reviewed

Longitudinal Registration of Chest CT Images With Radiation-Induced Lung Disease

Version 1 : Received: 18 December 2022 / Approved: 20 December 2022 / Online: 20 December 2022 (07:28:27 CET)

How to cite: Lin, F.; Li, Y.; Lee, C.; Lor, K.; Wang, H.; Chang, Y.; Chen, C. Longitudinal Registration of Chest CT Images With Radiation-Induced Lung Disease. Preprints 2022, 2022120356. https://doi.org/10.20944/preprints202212.0356.v1 Lin, F.; Li, Y.; Lee, C.; Lor, K.; Wang, H.; Chang, Y.; Chen, C. Longitudinal Registration of Chest CT Images With Radiation-Induced Lung Disease. Preprints 2022, 2022120356. https://doi.org/10.20944/preprints202212.0356.v1

Abstract

Longitudinal image registration of pulmonary computed tomography (PCT) images may serve as an essential tool for investigating the relationship between radiation dose distribution and the occurrence and phenotype of radiation-induced lung disease (RILD). Although numerous longitudinal registration algorithms have been developed for PCT, most similarity-based approaches are not suitable for PCT involving RILD due to the complex tissue variation between two PCT images. Moreover, conventional feature-based approaches might fail to find a sufficient number of matched pairs of feature points due to the disparate lung deformation caused by breathing and RILD. To overcome the challenges resulting from RILD, component structure coherence point drift (CSCPD) was proposed to establish a deformation model by decomposing the chest into several components and matching them with individual parameters based on coherence point drift (CPD). Moreover, a regional vascular point matching (RVPM) algorithm was proposed to generate a vascular subtree and to substantially increase the number of corresponding pairs between two images. Eventually, the components were recomposed and aligned by a thin plate spline algorithm. A performance assessment on 15 pairs of PCT images of patients with RILD yielded recall and precision values of 0.85 and 0.89 for RVPM, respectively. Moreover, the target registration error of CSCPD with RVPM (2.3 ± 1.79) was significantly better than that of conventional CPD with RVPM (2.95 ± 1.89) and conventional CPD (5.04 ± 2.87). Therefore, the proposed registration system is robust enough to address the disparate deformation of lungs with RILD, and it improves registration accuracy within the parenchyma.

Keywords

Component Structure Coherence Point Drift; parenchyma change induced by radiotherapy; computed tomography; feature point sampling; regional vascular point matching; longitudinal registration

Subject

Medicine and Pharmacology, Other

Comments (0)

We encourage comments and feedback from a broad range of readers. See criteria for comments and our Diversity statement.

Leave a public comment
Send a private comment to the author(s)
* All users must log in before leaving a comment
Views 0
Downloads 0
Comments 0
Metrics 0


×
Alerts
Notify me about updates to this article or when a peer-reviewed version is published.
We use cookies on our website to ensure you get the best experience.
Read more about our cookies here.