Influence of the Angle of Seismic Incidence of Long-Period Pulse-like Ground Motion on an Irregular Base-Isolated Building

Version 1 : Received: 1 September 2022 / Approved: 2 September 2022 / Online: 2 September 2022 (03:10:50 CEST)
Version 2 : Received: 28 September 2022 / Approved: 29 September 2022 / Online: 29 September 2022 (03:20:20 CEST)

A peer-reviewed article of this Preprint also exists.

Fujii, K. Influence of the Angle of Seismic Incidence of Long-Period Pulse-like Ground Motion on an Irregular Base-Isolated Building. Frontiers in Built Environment 2022, 8, doi:10.3389/fbuil.2022.1034166. Fujii, K. Influence of the Angle of Seismic Incidence of Long-Period Pulse-like Ground Motion on an Irregular Base-Isolated Building. Frontiers in Built Environment 2022, 8, doi:10.3389/fbuil.2022.1034166.

Abstract

In general, isolators and dampers used in seismically isolated buildings are designed to be isotropic in any horizontal direction. However, in the case of buildings with plan irregularities, their nonlinear responses depend on the direction of seismic loading. To discuss the influence of the angle of seismic incidence (ASI) on the nonlinear response of irregular building structures, it is important to define the angle of the critical axis of the horizontal ground motion. One possible choice is the “principal axis of ground motion” proposed by Arias (1970). However, because this principal axis is independent of the natural period of a structure, it could be complicated to use for seismically isolated structures with long natural periods. In this study, the influence of the ASI of long-period pulse-like seismic input on an irregular base-isolated building is investigated. First, the angle of the principal axis of ground motion is defined in terms of the cumulative energy input. Then, a nonlinear time-history analysis of a five-story irregular base-isolated building is performed using 10 long-period pulse-like ground motion records considering various ASIs. The results show that, compared with the principal axis of ground motion proposed by Arias, defining the principal axis of ground motion in terms of the cumulative energy input is more suitable for discussions concerning the influence of the ASI on the response of an irregular base-isolated building.

Keywords

base-isolated building, irregularity, angle of seismic incidence, pulse-like ground motion, energy input

Subject

Engineering, Civil Engineering

Comments (1)

Comment 1
Received: 29 September 2022
Commenter: Kenji Fujii
Commenter's Conflict of Interests: Author
Comment: During the reviewing process, I have made some corrections and replaced figures.
+ Respond to this comment

We encourage comments and feedback from a broad range of readers. See criteria for comments and our Diversity statement.

Leave a public comment
Send a private comment to the author(s)
* All users must log in before leaving a comment
Views 0
Downloads 0
Comments 1
Metrics 0


×
Alerts
Notify me about updates to this article or when a peer-reviewed version is published.
We use cookies on our website to ensure you get the best experience.
Read more about our cookies here.