Calibration of PurpleAir PA-I and PA-II monitors using daily mean PM2.5 concentrations measured in California, Washington, and Oregon from 2017 to 2021

Version 1 : Received: 9 May 2022 / Approved: 9 May 2022 / Online: 9 May 2022 (06:05:19 CEST)

A peer-reviewed article of this Preprint also exists.

Wallace, L.; Zhao, T.; Klepeis, N.E. Calibration of PurpleAir PA-I and PA-II Monitors Using Daily Mean PM2.5 Concentrations Measured in California, Washington, and Oregon from 2017 to 2021. Sensors 2022, 22, 4741. Wallace, L.; Zhao, T.; Klepeis, N.E. Calibration of PurpleAir PA-I and PA-II Monitors Using Daily Mean PM2.5 Concentrations Measured in California, Washington, and Oregon from 2017 to 2021. Sensors 2022, 22, 4741.

Abstract

Large quantities of real-time particle data are becoming available from low-cost particle monitors. However, it is crucial to determine the quality of these measurements. The largest network of monitors in the United States is maintained by the PurpleAir company, which offers two monitors: PA-I and PA-II. PA-I monitors have a single sensor (PMS1003) and PA-II monitors employ two independent PMS5003 sensors. We determine a new calibration factor for the PA-I monitor and revise a previously published calibration algorithm for PA-II monitors (ALT-CF3). From the PurpleAir API site, we downloaded 83 million hourly average PM2.5 values in the PurpleAir database from Washington, Oregon, and California between January 1, 2017 and September 8, 2021. Daily outdoor PM2.5 means from 194 PA-II monitors were compared to daily means from 47 nearby Federal regulatory sites using gravimetric Federal Reference Methods (FRM). We find a revised calibration factor of 3.4 for the PA-II monitors. For the PA-I monitors, we determined a new calibration factor (also 3.4) by comparing 26 outdoor PA-I sites to 117 nearby outdoor PA-II sites. These results show that PurpleAir PM2.5 measurements can agree well with regulatory monitors when an optimum calibration factor is found.

Keywords

low-cost particle monitors; calibration factor; PurpleAir; particles; PM2.5; ALT-CF3; algorithm; PMS1003; PMS5003

Subject

Environmental and Earth Sciences, Environmental Science

Comments (0)

We encourage comments and feedback from a broad range of readers. See criteria for comments and our Diversity statement.

Leave a public comment
Send a private comment to the author(s)
* All users must log in before leaving a comment
Views 0
Downloads 0
Comments 0
Metrics 0


×
Alerts
Notify me about updates to this article or when a peer-reviewed version is published.
We use cookies on our website to ensure you get the best experience.
Read more about our cookies here.