Preprint Article Version 2 Preserved in Portico This version is not peer-reviewed

Degradation Analysis of Thin Mg-xAg Wires Using X-Ray Near-Field Holotomography

Version 1 : Received: 21 July 2021 / Approved: 26 July 2021 / Online: 26 July 2021 (10:35:40 CEST)
Version 2 : Received: 6 December 2021 / Approved: 8 December 2021 / Online: 8 December 2021 (14:26:38 CET)

A peer-reviewed article of this Preprint also exists.

Meyer, S.; Wolf, A.; Sanders, D.; Iskhakova, K.; Ćwieka, H.; Bruns, S.; Flenner, S.; Greving, I.; Hagemann, J.; Willumeit-Römer, R.; Wiese, B.; Zeller-Plumhoff, B. Degradation Analysis of Thin Mg-xAg Wires Using X-ray Near-Field Holotomography. Metals 2021, 11, 1422. Meyer, S.; Wolf, A.; Sanders, D.; Iskhakova, K.; Ćwieka, H.; Bruns, S.; Flenner, S.; Greving, I.; Hagemann, J.; Willumeit-Römer, R.; Wiese, B.; Zeller-Plumhoff, B. Degradation Analysis of Thin Mg-xAg Wires Using X-ray Near-Field Holotomography. Metals 2021, 11, 1422.

Abstract

Magnesium-silver alloys are of high interest for the use as temporary bone implants due to their antibacterial properties in addition to biocompatibility and biodegradability. Thin wires in particular can be used for scaffolding, but the determination of their degradation rate and homogeneity using traditional methods is difficult. Therefore, we have employed 3D imaging using X-ray near-field holotomography with sub-micrometer resolution to study the degradation of thin (250 μm diameter) Mg-2Ag and Mg-6Ag wires. The wires were studied in two states, recrystallized and solution annealed to assess the influence of Ag content and precipitates on the degradation. Imaging was employed after degradation in Dulbecco’s modified Eagle’s medium and 10% fetal bovine serum after 1 to 7 days. At 3 days of immersion the degradation rates of both alloys in both states were similar, but at 7 days higher silver content and solution annealing lead to decreased degradation rates. The opposite was observed for the pitting factor. Overall, the standard deviation of the determined parameters was high, owing to the relatively small field of view during imaging and high degradation inhomogeneity of the samples. Nevertheless, Mg-6Ag in the solution annealed state emerges as a potential material for thin wire manufacturing for implants.

Keywords

X-ray computed tomography; magnesium-silver alloy; wire; degradation; near-field holotomography

Subject

Chemistry and Materials Science, Biomaterials

Comments (1)

Comment 1
Received: 8 December 2021
Commenter: Sebastian Meyer
Commenter's Conflict of Interests: Author
Comment: Stylistic adjustments:
- Unification of the greek symbols in Latex code from \mu to \upmu.
- Line break set appropriately
In Materials and Methods section:
- Heat treatment of the billets before extrusion at 450 °C for 16 hours instead of 500 °C for 8 hours.
- The last drawing step to 0.25 mm instead of 0.2 mm.
+ Respond to this comment

We encourage comments and feedback from a broad range of readers. See criteria for comments and our Diversity statement.

Leave a public comment
Send a private comment to the author(s)
* All users must log in before leaving a comment
Views 0
Downloads 0
Comments 1
Metrics 0


×
Alerts
Notify me about updates to this article or when a peer-reviewed version is published.
We use cookies on our website to ensure you get the best experience.
Read more about our cookies here.