New Methodological Approach Towards a Complete Characterization of Structural Fiber Reinforced Concrete by Means of Mechanical Testing Procedures

Version 1 : Received: 18 June 2020 / Approved: 19 June 2020 / Online: 19 June 2020 (04:24:48 CEST)

A peer-reviewed article of this Preprint also exists.

Alberti, M.G.; Picazo, Á.; Gálvez, J.C.; Enfedaque, A. New Methodological Approach towards a Complete Characterization of Structural Fiber Reinforced Concrete by Means of Mechanical Testing Procedures. Appl. Sci. 2020, 10, 4811. Alberti, M.G.; Picazo, Á.; Gálvez, J.C.; Enfedaque, A. New Methodological Approach towards a Complete Characterization of Structural Fiber Reinforced Concrete by Means of Mechanical Testing Procedures. Appl. Sci. 2020, 10, 4811.

Abstract

This work proposes a novel methodology for the complete characterization of fiber reinforced concrete (FRC). The method includes bending tests of prismatic notched specimens, based on the Standards for FRC, tensile and pure shear tests. The values adopted by the standards for designing FRC are the obtained from bending tests, typically fR3, even for shear and pure tension loading. This paper shows that the remaining strength of FRC, supplied by the fibers, depends on the type of loading. In the case of shear and tensile loading the prescriptions of the standards may be unsafe. In this work, the remaining halves of specimens subjected to bending test are prepared and used for shear and tension tests. This means significant savings in specimen preparation and a greater amount of information for structural use of FRC. The results provide relevant information for the design of structural elements of FRC compared with the only use of data supplied by bending tests. In addition, a video-extensometry system was used to analyze the crack generation and cracking patterns. The video-extensometry applied to shear tests allowed the assessment of the sliding values and crack opening values at the crack discontinuity. These values may be quite relevant for the study of the FRC behavior when subjected to shear according to the shear-friction model theories.

Keywords

fiber reinforced concrete; direct tensile test; push-off test; polyolefin fiber; digital image correlation

Subject

Engineering, Civil Engineering

Comments (0)

We encourage comments and feedback from a broad range of readers. See criteria for comments and our Diversity statement.

Leave a public comment
Send a private comment to the author(s)
* All users must log in before leaving a comment
Views 0
Downloads 0
Comments 0
Metrics 0


×
Alerts
Notify me about updates to this article or when a peer-reviewed version is published.
We use cookies on our website to ensure you get the best experience.
Read more about our cookies here.