Preprint Article Version 1 Preserved in Portico This version is not peer-reviewed

Statistical Approach to Spectrogram Analysis for Radio-Frequency Interference Detection and Mitigation in an L-band Microwave Radiometer

Version 1 : Received: 12 December 2018 / Approved: 13 December 2018 / Online: 13 December 2018 (08:12:14 CET)

A peer-reviewed article of this Preprint also exists.

Oh, M.; Kim, Y.-H. Statistical Approach to Spectrogram Analysis for Radio-Frequency Interference Detection and Mitigation in an L-Band Microwave Radiometer. Sensors 2019, 19, 306. Oh, M.; Kim, Y.-H. Statistical Approach to Spectrogram Analysis for Radio-Frequency Interference Detection and Mitigation in an L-Band Microwave Radiometer. Sensors 2019, 19, 306.

Abstract

For the elimination of radio-frequency interference (RFI) in a passive microwave radiometer, the threshold level is generally calculated from the mean value and standard deviation. However, a serious problem that can arise is an error in the retrieved brightness temperature from a higher threshold level owing to the presence of RFI. In this paper, we propose a method to detect and mitigate RFI contamination using the threshold level from statistical criteria based on a spectrogram technique. Mean and skewness spectrograms are created from a brightness temperature spectrogram by shifting the 2-D window to discriminate the form of the symmetric distribution as a natural thermal emission signal. From the remaining bins of the mean spectrogram eliminated by RFI-flagged bins in the skewness spectrogram for data captured at 0.1-s intervals, two distribution sides are identically created from the left side of the distribution by changing the standard position of the distribution. Simultaneously, kurtosis calculations from these bins for each symmetric distribution are repeatedly performed to determine the retrieved brightness temperature corresponding to the closest kurtosis value of three. The performance is evaluated using experimental data, and the error in the retrieved brightness temperature is observed to be less than approximately 3 K from a window with a size of 100 × 100 time-frequency bins according to the RFI levels and cases.

Keywords

radiometer; kurtosis; skewness; spectrogram; radio-frequency interference (RFI)

Subject

Engineering, Electrical and Electronic Engineering

Comments (0)

We encourage comments and feedback from a broad range of readers. See criteria for comments and our Diversity statement.

Leave a public comment
Send a private comment to the author(s)
* All users must log in before leaving a comment
Views 0
Downloads 0
Comments 0
Metrics 0


×
Alerts
Notify me about updates to this article or when a peer-reviewed version is published.
We use cookies on our website to ensure you get the best experience.
Read more about our cookies here.