Submitted:
24 November 2026
Posted:
25 November 2026
You are already at the latest version
Abstract
This paper presents a real-time, data-driven Structural Health Monitoring (SHM) system deployed on the Bolueta railway bridge (Bilbao, Spain), a singular bridge with a continuous configuration comprising a multi-span double-box-girder deck, V-shaped piers, and a twin-rib arch. The bridge was monitored during an approximately one-year track renewal campaign involving concrete chipping works on the ballastless track, requiring monitoring during both nighttime rehabilitation activities and uninterrupted normal railway operation. The implemented monitoring system is based on a modular architecture using MQTT over a 4G network for continuous data transmission, storage, visualization, and processing. The recorded data comprise acceleration, strain, relative displacement, and inclination measurements. Global finite element models were complementarily used for offline baseline verification by comparing their predictions with the measurements ob-tained from the monitoring system. To support operational decision-making, a real-time monitoring platform incorporating threshold-based alerts, machine-learning-based anomaly detection using identified natural frequencies (centered on a dense neural network classifier) and acceleration time histories (convolutional autoencoder), and a data contextualization tool was deployed. The results showed good agreement between measurements and numerical predictions, while no persistent deviation from the monitored reference condition was identified during the monitoring period. This case study demonstrates the applicability of modular, online, data-based SHM systems for supporting the assessment and management of railway bridges during complex maintenance operations.
Keywords:
structural health monitoring (SHM)
; railway bridges maintenance
; real-time monitoring
; machine learning
1. Introduction
Railway bridges, including metro viaducts, are critical assets of modern transportation infrastructure, ensuring safe and efficient operations. Many of these structures have been in service for several decades and are currently subjected to increasing traffic volumes, higher axle loads, and progressive ageing. Consequently, infrastructure managers require reliable methodologies capable of continuously assessing structural performance, supporting maintenance planning, and reducing the risk of unexpected failures [1,2,3].
Structural Health Monitoring (SHM) has emerged as one of the most widely used approaches for addressing these challenges by complementing conventional visual inspections with continuous measurements obtained from permanently installed sensing systems. Unlike periodic inspections, SHM enables the continuous assessment of structural behavior under real operating conditions, providing objective information that supports condition-based maintenance and more efficient management of bridge infrastructure [1,2,3]. In railway bridges, continuous monitoring is particularly valuable because the repeated passage of trains—especially frequent on metro viaducts—produces a large number of load cycles and imposes stringent safety and serviceability requirements [2,3].
Modern SHM systems integrate different sensing technologies according to the characteristics of the structure and the monitoring objectives. Strain gauges provide direct measurements of structural stresses and local load redistribution, whereas accelerometers are widely employed to characterize the global dynamic response of bridges. Additional instrumentation, including displacement transducers, inclinometers and environmental sensors, is frequently incorporated to facilitate the interpretation of structural behavior under operational conditions [5,6]. The integration of complementary sensing techniques has been shown to provide a more comprehensive assessment than individual measurement systems alone [3,5,6].
Among the different monitoring strategies, vibration-based SHM has received particular attention because changes in modal properties may reflect variations in the global stiffness and mass distribution of a structure [4,7]. Operational Modal Analysis (OMA), which estimates modal parameters from ambient or operational excitation without requiring controlled loading, has consequently become one of the most widely adopted methodologies for bridge monitoring [4,7]. Numerous studies have successfully applied OMA to railway bridges including train passages as operational excitation, demonstrating its capability to identify natural frequencies, damping ratios and mode shapes under normal service conditions [8,9].
Despite these advances, the practical implementation of vibration-based monitoring remains challenging because modal properties are also influenced by environmental and operational variability. Temperature fluctuations, train characteristics, traffic intensity, and axle loads may all induce variations in the measured dynamic response that are unrelated to structural deterioration [10,11]. Consequently, distinguishing normal operational variability from genuine structural changes remains one of the principal challenges in long-term bridge monitoring [10,11,12,13].
To improve the interpretation of monitoring data, experimental observations are increasingly combined with physics-based numerical models. Finite element (FE) models provide a framework for reproducing the structural response, evaluating hypothetical damage scenarios, and interpreting measured behavior. Furthermore, model updating techniques enable uncertain structural parameters to be calibrated using monitoring data, improving the agreement between numerical predictions and experimental observations and increasing confidence in subsequent structural assessments [6,12]. The integration of continuous monitoring with updated FE models therefore provides complementary information that strengthens the reliability of structural assessment [2,6,12].
Recent advances in data-driven methodologies have further expanded the capabilities of SHM systems. Statistical pattern recognition, principal component analysis, clustering techniques, support vector machines and deep neural networks have demonstrated considerable potential for identifying subtle changes in structural behavior while accounting for environmental and operational variability [13,14,15,16,17,18]. As a result, SHM has progressively evolved from conventional threshold-based monitoring towards automated anomaly detection and decision-support methodologies capable of extracting meaningful information from large volumes of monitoring data [14,15,16,17,18].
Recent developments have extended SHM beyond data acquisition towards integrated monitoring frameworks incorporating wireless sensor networks, cloud computing, Internet of Things (IoT) technologies, and Digital Twins [19,20,21,22,23,24,25]. These technologies facilitate the continuous acquisition, transmission, processing, and visualization of monitoring data while providing scalable architectures for long-term infrastructure management [19,20,21,22,23,24,25]. An IoT-based Digital Twin utilizing wireless sensors, edge-cloud computing, and machine learning for anomaly detection is presented in [20], though its validation is limited to a basic single-span railway bridge using minimal instrumentation. Likewise, recent smart SHM platforms have incorporated visualization and decision-support functionalities to improve the interpretation of monitoring results [21], while Digital Twin frameworks have enabled the integration of sensing data, numerical models and digital asset representations within unified environments for infrastructure management [22,24,25].
Although these developments have considerably advanced the capabilities of SHM systems, most published studies focus on specific aspects of the monitoring process, such as sensing technologies, numerical modelling, damage detection algorithms or digital platforms. Comprehensive implementations integrating heterogeneous sensing technologies, long-term operational monitoring, automated anomaly detection and engineering-oriented visualization within a single operational framework remain comparatively limited, particularly for in-service railway bridges monitored during maintenance or renewal works [20,21,22,23,24,25].
This study contributes to the field through the one-year deployment of a modular and scalable real-time SHM framework on the Bolueta railway bridge during the Metro Bilbao line renewal. The system continuously collects strain, acceleration, relative displacement, and inclination measurements to assess structural behavior. The core value of this work lies in the automated integration of these multi-sensor measurements into a hybrid anomaly detection system. This architecture triggers real-time alerts when thresholds derived from offline finite element models, regulatory codes, or initial baseline periods are exceeded, while simultaneously employing machine learning over defined aggregation periods to evaluate vibration features and acceleration signatures. Beyond simple alerts, the proposed framework provides interactive diagrams and geometric background to deliver the contextual interpretation required to actively support structural decision-making. In addition, once the full year of monitoring data became available after the conclusion of the practical monitoring campaign, a more detailed retrospective assessment of the potential of machine-learning techniques was conducted.
The remainder of this paper is organized as follows. Section 2 describes the monitored bridge, the modular SHM architecture, the deployed instrumentation, and the monitoring campaign. Section 3 presents the experimental results, including the analysis of the monitored variables, comparison with finite element models predictions, machine-learning anomaly detection algorithms and the histogram-based representation of their results, including a sensitivity characterization of the potential applicability of machine-learning techniques using the complete one-year monitoring dataset, and the real-time monitoring platform. Section 4 discusses the applicability of the proposed framework for railway bridge monitoring, including the practical limitations and data requirements associated with the operational use of machine-learning methods. Section 5 presents the main conclusions.
2. Materials and Methods
2.1. Bolueta Railway Bridge
The Bolueta railway bridge spans the Nervión River between Bilbao and Etxebarri, Spain, and was designed by civil engineers Leonardo Fernández Troyano and Javier Manterola Armisén. The structure serves as part of the Metro Bilbao Line 1 and Line 2 infrastructure, connecting the Bolueta station with the adjacent tunnel. A general view of the bridge and its structural layout are shown in Figure 1.
The bridge has a singular continuous structural configuration comprising a multi-span prestressed-concrete double-box-girder deck integrated with a twin-rib arch crossing the Nervión River. The bridge is constructed of both prestressed and reinforced concrete, with prestressing applied mainly to the deck box girders, including the region where they merge with the arch. The V-shaped piers are monolithically connected to the deck girders, with elastomeric bearings located at their bases, whereas the twin-rib arch is clamped at both abutments. The inclined piers adjacent to the arch are rigidly connected to both the deck girders and the arch foundations. In addition, the deck is supported by bearings at both abutments. Consequently, the bridge is a continuous hyperstatic structure. This structural configuration provides a high capacity for stress redistribution under localized actions, while inherently transmitting structural vibrations.
During the second half of 2024 and most of 2025, Metro Bilbao carried out a major track renewal intervention, including the almost complete rehabilitation of the ballastless track and the removal of an existing railway switch. The intervention involved intensive concrete chipping works on the ballastless track. These renewal works were carried out during scheduled nighttime periods, while the bridge remained in normal operation at all other times. For safety reasons, the infrastructure manager required continuous structural monitoring to assess the structural response under both construction and operational loading conditions.
2.2. Monitoring Instrumentation
To monitor the structural response of the bridge during the track renewal intervention, a multi-sensor instrumentation system was deployed to continuously measure accelerations, strains, inclinations, and relative displacements. The instrumentation layout was defined according to the expected structural behavior and accessibility constraints. The monitoring system comprised eight triaxial accelerometers, ten strain measurement points, two dual-axis inclinometers, and seven linear displacement potentiometers. The complete sensor distribution is presented in Figure 2.
The inertial instrumentation consisted of four high-sensitivity force-balance triaxial accelerometers (GeoSIG AC-73, configured to ±2 g), four high-resolution MEMS triaxial accelerometers (TE Connectivity 4630, ±2 g) and two dual-axis electrolytic inclinometers (Jewell Instruments Clinometer Pak). The use of both force-balance and MEMS accelerometers significantly reduced the overall cost of the monitoring system by reserving the high-sensitivity (5 V/g) force-balance accelerometers for ambient vibration measurements, eigenfrequency extraction and AI-based anomaly detection, while using MEMS units (1 V/g) to extend in-service and nighttime acceleration level measurements to additional sections of the bridge. The combination and number of inertial sensors were constrained by the considerably higher cost of the force-balance accelerometers and the available acquisition system capacity. In accessible regions, the sensors were installed on the underside of the deck girders using custom-made steel fixings, whereas in regions without access to the underside of the deck, inertial sensors were installed above the deck. Due to the limited accessibility of the arch, the fact that the bridge deck adjacent to the tunnel had already been intervened prior to the installation of the monitoring system, and the need to limit cable lengths to minimize signal attenuation, degradation, and electromagnetic interference, no additional accelerometers were deployed beyond the midspan of the arch.
The remaining instrumentation comprised ten strain measurement points, each consisting of two long-gauge concrete surface strain gauges (Tokyo Measuring Instruments Laboratory PL-120-11-1LJC-F) connected in a half-Wheatstone bridge configuration and installed at the span centers of the double-box-girder deck, together with seven linear displacement potentiometers installed at the bearings of the train station-side abutment and at the base of one V-shaped pier. Owing to the lack of access to the underside of the arch span and the immediately adjacent deck, strain measurements could not be implemented in these sections.
The instrumentation was connected to four HBM QuantumX acquisition modules. Two MX1601B modules were dedicated to the inertial instrumentation, whereas two MX1615B universal modules acquired the strain and relative displacement measurements. Representative examples of the installed instrumentation are presented in Figure 3.
2.3. Monitoring Campaign
The monitoring system was deployed for one year during the renewal works of the Metro Bilbao railway track over the Bolueta bridge. Throughout this period, measurements were acquired during both normal railway traffic and nighttime maintenance activities, providing the opportunity to characterize and compare the structural response under both operational and maintenance conditions.
Since the instrumentation was installed after the maintenance works had already commenced, the deployment strategy prioritized rapid installation, minimal intervention on the existing structure, and the use of commercially available and reliable sensing technologies that could be integrated without interfering with either railway operations or the ongoing works.
Data acquisition started in August 2024 and continued until September 2025, covering approximately one year of continuous operation. The inertial sensors were sampled at 200 Hz, whereas the remaining sensors were acquired at 50 Hz. All acquisition channels were synchronized using a common timestamp generated by the acquisition system. This paper builds upon the preliminary conference paper presented in [27]. In the present work, the complete dataset is analyzed, enabling a more detailed examination of the monitoring campaign and its outcomes based on the different methodologies considered in this case study, as well as more robust conclusions and a more comprehensive evaluation of the machine-learning algorithms. In particular, this work incorporates a convolutional-autoencoder-based approach for analyzing acceleration time-series signatures and an enhanced frequency-based anomaly detector. These developments are complemented by an advanced contextualization tool featuring interactive histograms, which facilitates the exploration and interpretation of detected anomalies, together with a conversational assistant embedded in the graphical user interface (GUI).
2.4. Real-Time Monitoring System Architecture
The monitoring system implemented on the Bolueta railway bridge was based on a modular real-time architecture previously developed by the authors for Internet of Things (IoT)-based structural health monitoring applications [20] and adapted to the specific requirements of the present bridge monitoring deployment. The framework follows a layered design in which the sensing, communication, and processing layers are logically decoupled, enabling the integration of heterogeneous sensing technologies, data acquisition hardware, and communication protocols through limited modifications to the middleware. This modular approach facilitates the incorporation of additional sensing devices and analytical functionalities while preserving the overall software architecture. The real-time monitoring system architecture is shown in Figure 4.
The sensing layer corresponds to the instrumentation described in the previous section. Data acquisition is carried out through two control cabinets installed beneath the bridge, each housing two HBM QuantumX acquisition modules, an industrial computer, a 4G router, and the associated communication and power equipment. All measurement channels are synchronously acquired before transmission, ensuring a common time reference for the simultaneous recording of accelerations, strains, relative displacements, and inclinations.
The on-site computers operate as edge gateways, collecting the measurements from the acquisition modules and transmitting them to the remote infrastructure via the MQTT protocol over the 4G network. Data ingestion and routing are managed through a Node-RED middleware deployment hosted on the on-premises infrastructure, effectively decoupling the acquisition hardware from the downstream processing services while allowing future modifications to the monitoring configuration without requiring changes to the overall software architecture.
The acquired measurements are stored in a centralized database with time-stamped records and processed in near real time. This infrastructure enables continuous visualization of the structural response, comparison of bridge behavior during normal railway operation and nighttime track renewal activities, verification of the measured response against predefined operational thresholds, automated email alerts when threshold exceedances are detected, and engineering-oriented interpretation of machine-learning-based anomaly detection results. Experimental measurements also provide the basis for offline comparison with finite element predictions to support the structural assessment of the bridge. Furthermore, the proposed modular architecture provides a suitable basis for future integration into more complete Digital Twin environments and other long-term structural health monitoring applications.
To enhance operational reliability, all acquired measurements are simultaneously stored on local solid-state drives installed within the acquisition cabinets, ensuring data availability during temporary communication outages and enabling complementary offline analyses. The control cabinets are equipped with uninterruptible power supply (UPS) units, while the acquisition software is configured to resume operation automatically following power restoration. Given the electromagnetic environment associated with the railway catenary system, shielded cables were employed throughout the installation, with the cable shields grounded at the acquisition cabinets to minimize electromagnetic interference.
2.5. Finite Element Models
Finite element (FE) models were developed to support the interpretation of the measurements obtained during the monitoring campaign. Although FE models constitute a well-established tool for structural design, their application to an existing structure under operational conditions provides a physically based reference for comparison with the monitored response rather than an exact reproduction of the measured behavior. Therefore, the structural idealization was aimed at obtaining representative orders of magnitude while avoiding modelling inconsistencies.
Three FE models of the Bolueta bridge were developed. A preliminary beam model was implemented in SAP2000 using two-node frame elements with associated cross-sections and material properties, providing natural frequencies, mode shapes, deflections, rotations and strains associated with the vertical response of the bridge. A second model was developed in SAP2000 using shell elements with assigned thicknesses, allowing a more realistic representation of the mass distribution while providing equivalent response quantities in three dimensions. Finally, a three-dimensional solid model was generated in ANSYS, where the geometry is explicitly represented, allowing strains and stresses to be directly obtained throughout the structure.
Figure 5 illustrates an initial cross-check between the two independent three-dimensional modelling approaches, which were chosen due to their more realistic stiffness and mass distribution to further provide physical insight into the measurements. The first natural mode, which is predominantly lateral with a minor vertical component, is considered as a useful reference for assessing the consistency of the overall mass and stiffness distribution between the two numerical idealizations. The good agreement between the two models provides confidence in their overall structural representation, suggesting that no significant implementation errors are present. However, the lateral modes will not be considered in the subsequent model adjustment, as the monitoring will mostly focus on vertical accelerations and the eigenfrequencies extracted from these, together with vertical bending strain measurements.
Prestressing was not explicitly represented in the global FE models, which assume a continuous linear elastic structural medium. The Young’s modulus initially adopted in the analyses (3452530 Tn/m²) corresponds to the value reported in the structural calculations prepared by Carlos Fernández Casado S.L. for the load test performed in 2002 [28]. Permanent monitoring does not constitute a standardized load test. Nevertheless, its implications for comparison with finite element models are similar, since the effects of self-weight, permanent loads, and prestressing were already present in the structure when the sensors were installed. Accordingly, the analyses were performed based on the principle of superposition and were limited to the incremental structural response induced by variable actions associated with railway traffic and maintenance works.
Modal analyses were first performed using the two selected FE models with the original design material properties to determine natural frequencies and corresponding mode-shape patterns of the bridge. Considering both lateral and vertical global vibration modes, most of the structural modal mass is mobilized in the approximately 2–10 Hz frequency range. Given the structural complexity of the bridge—a continuous, approximately 200 m long, multi-span structure comprising different structural typologies and exhibiting several closely spaced modes—and the limited spatial resolution of the monitoring system, the available experimental data did not allow the reliable matching of experimentally identified modes with their numerical counterparts. Consequently, a reliable mode-by-mode experimental-numerical updating of the FE models was not attempted. Instead, with a slight upward adjustment of the concrete elastic modulus, the adjusted FE model provides a consistent representation of the initially measured vertical dynamic response, establishing a physically plausible reference for subsequent comparisons. Based on the modal analysis of the adjusted ANSYS solid model, the three modes at 3.9 Hz (vertical relative modal participation = 1.00), 6.2 Hz (longitudinal relative modal participation = 0.88), and 8.9 Hz (vertical relative modal participation = 0.58; longitudinal relative modal participation = 1.00) were selected among the modes with an appreciable vertical component, as they exhibited the highest relevant modal mass participation factors. Figure 6 presents the selected vibration modes and their corresponding modal mass participation factors predicted by the adjusted ANSYS solid model, which was considered the most suitable model for this purpose because of its greater geometric realism. The SAP2000 shell model was adjusted in the same manner, yielding similar results for the corresponding vibration modes. The adjusted FE models were then used to estimate bridge strains under representative railway loading, considering the train loading configuration defined for the 2002 load test. The resulting analytical strain estimates were compared with the strain measurements acquired during the monitoring campaign after removing their long-term components. Since strain measurements from the 2002 load test were not available, no direct validation against the original load test could be performed. The comparison between numerical predictions and experimental measurements is presented in Section 3.4.
3. Results
3.1. Acceleration Measurements
Since the renewal works had already started before TECNALIA implemented the continuous monitoring system described previously, the contractor TECSA carried out preliminary comparative measurements to support the continuation of the works, confirming that the accelerations generated by the hydraulic hammer were comparatively lower than those produced by passing trains. Likewise, before the implementation of the continuous monitoring system, TECNALIA conducted an additional site visit and recorded acceleration measurements during a night of hydraulic hammer operation at distances of approximately 10–15 m from the machine. The same conclusions were reached, and were later confirmed by the continuous monitoring system, whose results are presented below.
The monitoring system acquires acceleration measurements at a sampling frequency of 200 Hz and applies a 50 Hz low-pass Bessel filter before transmitting the data to the cloud. In general, acceleration measurements benefit from appropriate signal filtering. A sampling frequency substantially higher than the filter cut-off frequency is recommended to provide sufficient resolution for the numerical implementation of the filter. Owing to the monitoring architecture described in Section 2.4, this approach is suitable for both data transmission and storage, either in the cloud or locally.
European code EN 1990 A2 [29] establishes a limit of 0.5 g for the vertical deck acceleration of ballastless railway bridges to ensure operational safety. Although the origin of this value is uncertain, it is generally considered to result from the application of a safety factor of approximately two to an acceleration level close to 1 g, intended to prevent loss of wheel–rail contact. [30] questioned this assumption and pointed out that, unlike the limit established for ballasted tracks, the corresponding value for ballastless tracks has not been experimentally demonstrated. It should be noted, however, that the Eurocode limit applies to vertical acceleration components up to 30 Hz. Consequently, after transmission, the received signals were post-processed using a second low-pass Bessel filter with a cut-off frequency of 30 Hz to verify compliance with this criterion. The resulting vertical accelerations, although relatively high, generally remained below the prescribed limit during train passages. Representative records obtained from the force-balance accelerometers installed at different bridge locations are presented in Figure 7 after application of the 30 Hz Bessel filter. A Butterworth filter, owing to its steeper attenuation characteristics, would have produced significantly lower acceleration amplitudes; however, the Bessel filter was intentionally adopted because it better preserves the waveform (allowing for further offline analysis of acceleration signals downloaded from the system) and provides higher estimated acceleration levels than a Butterworth filter with the same cut-off frequency, resulting in a more conservative assessment of compliance with the Eurocode limit.
The MEMS accelerometers exhibited a similar overall response, although with lower sensitivity. Consequently, they were not used for natural frequency identification, as they can only capture train or rehabilitation work-induced vibrations, rather than ambient vibrations. It was also observed that some of these lower-cost sensors deteriorated after prolonged exposure to the outdoor environment or experienced mounting problems.
The relatively high acceleration levels measured during train passages could be a contributing factor to the progressive degradation of the track system, which was subsequently addressed by the track renewal works.
The accelerations generated during nighttime maintenance works, when trains were not operating, occasionally exceeded the thresholds established by the monitoring system. Since these construction-induced actions are not regulated, the alarm thresholds were defined using the acceleration levels measured during normal daytime railway traffic as the reference condition. The thresholds were established from the real-time monitoring signals, corresponding to data sampled at 200 Hz and filtered at 50 Hz before transmission. This filtering was retained for this alarm analysis because the objective was to compare train- and works-induced accelerations using the same monitoring data. The additional 30 Hz filtering was only applied later for the evaluation of operational vertical accelerations in accordance with Eurocode.
Whenever an alarm threshold was exceeded, notifications were automatically issued in near real time by e-mail to METRO BILBAO, TECSA and TECNALIA. In addition, remote access to the dashboards of the real-time monitoring platform was provided for continuous visualization of the monitored data (Figure 9 shows an example query to InfluxDB.).
In general, when an occasional nighttime acceleration alarm was triggered, it was limited to the bridge span and girder where the maintenance works were being carried out, reflecting the localized nature of the construction-induced excitation. The vibrations were not significantly transmitted to the remaining accelerometers, indicating that the measured response remained localized. This is consistent with the limited mobilization, due to nighttime works, of the global structural vibration modes predicted by the FE model. Nevertheless, the low-frequency vibrations can be easily perceived by the workers. Likewise, vibrations generated in the arch were not significantly transmitted to the girder spans, and vice versa.
Figure 7.
Representative approximately one-month records of vertical accelerations measured by the force-balance accelerometers installed at different bridge locations after application of a 30 Hz low-pass Bessel filter.
Figure 7.
Representative approximately one-month records of vertical accelerations measured by the force-balance accelerometers installed at different bridge locations after application of a 30 Hz low-pass Bessel filter.

Figure 8.
Representative approximately one-month records of vertical accelerations measured by a MEMS accelerometer after application of a 30 Hz low-pass Bessel filter.
Figure 8.
Representative approximately one-month records of vertical accelerations measured by a MEMS accelerometer after application of a 30 Hz low-pass Bessel filter.

Figure 9.
Example of the maximum absolute accelerations recorded during one night of maintenance works in Span 3. The ordinate axis represents acceleration in units of g. Intermediate tick labels are automatically displayed by the InfluxDB dashboard using the SI prefix m (e.g., 200m = 0.2 g = 200 mg). The abscissa shows the date and time as displayed in this part of the monitoring platform. Screenshot of the online InfluxDB dashboard included in the real-time monitoring system architecture.
Figure 9.
Example of the maximum absolute accelerations recorded during one night of maintenance works in Span 3. The ordinate axis represents acceleration in units of g. Intermediate tick labels are automatically displayed by the InfluxDB dashboard using the SI prefix m (e.g., 200m = 0.2 g = 200 mg). The abscissa shows the date and time as displayed in this part of the monitoring platform. Screenshot of the online InfluxDB dashboard included in the real-time monitoring system architecture.

Besides the vertical acceleration limit specified in the Eurocode, the first lateral natural frequency is another dynamic parameter commonly considered in the assessment of railway bridges. In particular, from the lateral acceleration spectra recorded by the force-balance accelerometers, the first lateral natural frequency was experimentally identified at approximately 2.5 Hz. Although relatively low, intrinsic to the bridge design, this value is well above the 1.2 Hz limit specified in European code EN 1990 A2 [29], indicating compliance with the minimum lateral-frequency criterion.
3.2. Strain Measurements
To simplify the installation, given the complexity of accessing the underside of the bridge using an elevating platform and fixing, cabling and protecting the strain gauges, a half-Wheatstone bridge configuration was adopted for all the concrete surface strain gauges. This configuration provides higher sensitivity than a quarter-bridge arrangement when measuring axial and bending strains at the selected locations, while also allowing compensation for temperature variations. One of the gauges in each half-bridge was installed at the measurement point, whereas the second gauge acted as a compensation gauge, being subjected to the same temperature but not expected to experience mechanical strain. Nevertheless, although the half-Wheatstone bridge configuration generally provides good temperature compensation, long-term strain measurements were observed to be affected by seasonal and environmental temperature variations.
A representative example of strain measurements is presented in Figure 10. During the nighttime maintenance works, isolated strain peaks comparable to those produced by train passages were occasionally recorded. However, the measured strains always returned to their prior levels once the construction-induced excitation ceased, indicating that the response remained fully recoverable. Furthermore, the microstrain values recorded during the nighttime maintenance works did not exceed those measured during normal daytime railway operation. Therefore, the recorded values were not considered indicative of structural risk.
Moreover, over the long term, temperature effects are clearly observed in the measurements, despite the half-bridge configuration of the strain gauges. To investigate the influence of ambient temperature on the recorded strains, a linear regression analysis was performed using the strain measurements from the gauges installed on the north girder and the ambient temperature during February 2025. This specific month was analyzed because warning messages were triggered for some of these gauges after exceeding the thresholds established from the initial measurements acquired in August–September 2024, although similar temperature-related trends have been consistently observed throughout the monitoring period. As shown in Figure 11, the temporal evolution of the strain measurements exhibits a clear correspondence with the variations in ambient temperature throughout the analyzed period. The resulting coefficient of determination was 0.9304, indicating that approximately 93% of the variability in the strain measurements can be explained by changes in the ambient temperature. These results suggest that the triggered warnings were primarily related to the observed seasonal temperature effects, with no corresponding evidence of changes in the structural response. Furthermore, the observed response was reversible, with the warnings ceasing after this period.
To evaluate the short-term structural response associated with train passages, a 0.1 Hz high-pass Butterworth filter was applied to the strain measurements to remove the long-term components attributed to temperature variations. The cutoff frequency was selected based on an iterative assessment of the filtered signals, as reducing the cutoff frequency to 0.05 Hz did not result in significant changes in the identified train-induced response. This choice of cutoff frequency aligns with established baseline-correction protocols in bridge diagnostics for isolating vehicle-induced strain responses from low-frequency environmental drifts [31]. The resulting records exhibit relatively consistent strain peaks associated with individual train passages.
After filtering the long-term components, the strain measurements remained stable throughout the monitoring period. Figure 12 compares representative filtered records obtained during the first months of monitoring with those measured approximately one year later, showing no appreciable differences in the strain response associated with train passages.
3.3. Relative Displacement and Inclination Measurements
Relative displacement sensors installed at the abutments and at the base of the pier, together with inclinometers located in the arch region, were incorporated into the monitoring system to detect possible global structural movements, including cumulative rotations or irreversible displacements that could indicate changes in the structural behavior of the bridge.
As shown in Figure 13, the inclination records exhibited transient peaks during train passages. However, after each train passage, the measured inclination consistently returned to its initial value, with no evidence of residual or cumulative rotation. Throughout the monitoring period, the baseline remained oscillatory, with absolute variations below 0.1°. Likewise, the relative displacements at the bearings remained negligible during train passages. The recorded displacements reached tens of millimeters over the long term, predominantly driven by seasonal thermal movements of the bridge, although these measurements are also inherently affected by the thermal response of the sensors and their metallic mounting brackets.
Overall, the inclination and relative displacement measurements indicate that no residual or cumulative response was identified at the monitored locations during the monitoring campaign.
3.4. Finite Element Model Comparison
The adjusted finite element models were used as an offline physical reference for interpreting the structural response measured during the subsequent monitoring campaign. Despite not being the primary objective of this study, these models serve to provide a physical plausibility check of the measured quantities. Here, a sample comparison is shown considering selected vertical frequencies identified from operational measurements and strain increments produced by railway traffic.
To compare the monitored and numerical dynamic responses in terms of natural frequencies, the target vertical frequencies (presented in Figure 6) were extracted from randomly selected 1-hour acceleration records acquired while the bridge was in service and distributed over the first nine months of the monitoring period. Since each record contains ambient vibrations together with train passages and free-vibration response, an automatic routine was applied to remove the intervals affected by train-induced vibrations. To address the high modal density of the structure, the remaining train-free signals were demeaned, normalized, and processed using Welch power spectral density estimates from the two closest available sensors capable of capturing the target analytical modes (installed at Span 5 and the adjacent arch). Both spectra were combined through their geometric mean to enhance frequency components consistently present in both channels. The procedure to remove train-induced responses is imperfect and may retain or discard short signal segments of variable lengths, introducing an additional source of uncertainty in the identified frequencies. Furthermore, due to the limited spatial density of the monitoring system, a full modal shape verification cannot be guaranteed. However, the three target vertical natural frequencies satisfying the predefined criteria were extracted and retained, providing experimental frequencies that reasonably correspond to the vertical modes presented in Figure 6 to examine their consistency with the adjusted FE model. Figure 14 illustrates the evolution of these three vertical frequencies over the first nine months of monitoring, showing reasonable agreement with the adjusted models described in Section 2.5 despite environmental and operational variations.
The adjusted finite element model (Figure 6) yielded analytical vertical frequencies of approximately 3.90 Hz, 6.20 Hz, and 8.90 Hz, demonstrating a highly reasonable agreement with the experimental data. This manual calibration was intentionally performed using the initial average frequencies from September 2024 (3.784 Hz, 6.144 Hz, and 8.944 Hz, respectively) to establish a representative baseline. Over the 9-month period, the identification routine yielded overall average frequencies of 3.722 Hz, 6.126 Hz, and 9.052 Hz for f₁, f₂, and f₃. These stable averages, extracted from a subset of 36 randomly selected records due to the massive computational volume of continuous 200 Hz data, and the inherent fluctuation of the curves suggest that no consistent structural changes or damage occurred during this timeframe. However, this method is inherently limited by the low spatial density of the sensors and the complex vibrational behavior of the bridge. The dual physical and computational challenge motivates the implementation of the automated machine-learning framework detailed in the next Section 3.5, which is specifically designed to handle the continuous high-volume data streams and analyze the response spectrum more comprehensively. Regarding the above shown results, the reference period of approximately 9 months has been adopted in historically reputed bridge-monitoring studies [32,33] to characterize the natural variability of modal properties under changing environmental and operational conditions. Consequently, while the comprehensive automated analysis of the entire spectral response across different frequency bands is subsequently addressed through the machine-learning framework in Section 3.5, this 9-month window successfully captures the primary seasonal patterns necessary to confirm the physical plausibility of both the numerical model and the sensor data.
The finite element analyses considered the train loading configuration defined for the 2002 load test. Specifically, a quasi-static analysis was performed by scaling the nominal static axle loads with the corresponding dynamic amplification factors defined in [28]. This procedure yields dynamic axle loads of 14.6 and 15.5 tonnes for the fully loaded condition, which were directly adopted in the numerical model for a representative 16-axle train. Although two trains may be occasionally present on the bridge at the same time, the measurements did not show simultaneous train passages through the same span on the two tracks. The strain records are dominated by the response associated with the train passing through a monitored girder, while the passage of a train on the opposite track, occurring within a short time interval, produces a substantially smaller response with a clear time lag. Thus, the simulations were performed with a single train acting on one bridge girder (track) at a time. The resulting analytical strain values were slightly higher than those obtained from the filtered measurements, providing a conservative prediction while remaining within the same order of magnitude, thereby confirming the physical plausibility of the monitored response.
For the strain comparison, the adjusted SAP2000 shell model was used because the bridge deck can be adequately idealized as a system of structural planar elements, offering a computationally efficient model to compare with the strain-gauge measurements.
Figure 15.
(a) Example of filtered strain measurements over several months after applying a 0.1 Hz high-pass Butterworth filter, showing the strain increments associated with train passages. (b) Corresponding shell strain (longitudinal at the bottom face) estimated using the SAP2000 model for Span 3.
Figure 15.
(a) Example of filtered strain measurements over several months after applying a 0.1 Hz high-pass Butterworth filter, showing the strain increments associated with train passages. (b) Corresponding shell strain (longitudinal at the bottom face) estimated using the SAP2000 model for Span 3.

Table 1.
Selected comparison results for the three interior spans of the box-girder deck between the maximum positive strain (tensile strain) increments associated with train passages in the monitoring data and the corresponding quasi-static predictions from the shell model at the strain-gauge locations.
Table 1.
Selected comparison results for the three interior spans of the box-girder deck between the maximum positive strain (tensile strain) increments associated with train passages in the monitoring data and the corresponding quasi-static predictions from the shell model at the strain-gauge locations.
| Span | Measured train-induced strain increment (µm/m) | SAP2000 quasi-static strain (µm/m) | Measured-to-predicted ratio |
| 2 | 25 | 43 | 0.58 |
| 3 | 25 | 39 | 0.64 |
| 4 | 25 | 46 | 0.54 |
The SAP2000 shell model predicts higher strains than those measured experimentally across the three interior spans. The experimental values range between 54% and 64% of the corresponding numerical predictions, while remaining within the same order of magnitude. This discrepancy is considered reasonable given the dynamic nature of the experimental train-induced response, whereas the finite element model adopted a quasi-static approach amplified by a dynamic factor as previously explained. The lower experimental values indicate that the actual dynamic response during the monitored train passages remained below the quasi-static response predicted by the numerical model. Unless significant resonance occurs in the structure, the quasi-static response predicted by the analytical model is expected to be higher and more conservative than the dynamic measurements.
It should be noted that the present monitoring campaign was not intended to constitute a normative load test, as it did not involve controlled static loading or the measurement of static deflections.
The relatively low measured strain levels should also be considered in relation to the location of the external strain gauges, which were installed on the accessible outer surfaces of the girders. Direct strain measurements at the reinforcement level would require intrusive interventions, which conflict with structural preservation principles and the need for rapid installation. The monitoring system was consequently conceived as a non-intrusive comparative control of the structural response during the renovation works.
In any case, the monitoring system thresholds were established considering both the strain levels observed at the beginning of the monitoring period (including environmental effects) and the train-induced numerical predictions, providing reference values for the control of the subsequent structural response regarding the surface strain measurements.
3.5. Machine Learning-Based Anomaly Detection
To address the inherent complexity of the structure and the continuous stream of monitoring data, and to provide more robust criteria than conventional warning thresholds, machine-learning techniques were implemented within the monitoring architecture to automatically process incoming data. Two complementary anomaly detection algorithms were implemented within the monitoring platform. One algorithm (3.5.1) is based on the frequency features identified from the acceleration measurements, whereas the second one (3.5.2) employs a convolutional autoencoder operating directly on the acceleration time histories without prior frequency identification.
The available instrumentation was primarily intended for monitoring the bridge during the aforementioned renovation works, rather than for permanent modal identification, which would have required a more extensive network of high-sensitivity accelerometers than could be accommodated within the project’s budget constraints. Consequently, mode shape identification was not pursued. Instead, the frequency-domain machine-learning algorithm analyzed each accelerometer independently using frequency spectrum-based processing over distinct frequency peaks, which were computed from both free (response remaining after the train has passed the measurement point) and ambient records, with them automatically extracted after removing the train-passage response through an automated processing routine. The resulting frequency features were subsequently used as input features for the frequency-based algorithm, whose implementation in the monitoring platform is presented later in Figure 16. In parallel, the convolutional autoencoder operates directly on the measured acceleration time histories, without requiring prior frequency identification, and considers both free-vibration records and train-passage responses; its implementation in the monitoring platform is shown later in Figure 17. Once pretrained using an initial one-month set of reference data representing normal structural behavior, both algorithms were deployed in the monitoring platform to detect anomalous responses while accounting for the environmental and operational variability represented in the training dataset. Their ability to distinguish normal variability from anomalous behavior therefore depends strongly on the duration and representativeness of that dataset. Early deployment using a limited initial dataset can mitigate the lack of extensive training by generating histograms in the form of heat maps that provide an intuitive and comprehensive overview of the inference process. On the resulting heat maps, the highest density of occurrences is concentrated in the upper band with the highest normality score, reflecting a high probability of baseline conditions. Consequently, if the bridge response aligns consistently with the learned baseline, this upper band will remain predominantly populated, while the remaining bands will appear sparsely populated. This heat map visualization layout is integrated into the user interfaces of the monitoring platform, as illustrated later in the aforementioned Figure 16 and Figure 17. Conversely, an increased population density in the lower bands during these early monitoring stages may indicate either structural deterioration or, more probably, a need for model retraining, which can be further evaluated using other existing thresholds alongside downloaded historical response and environmental data. Once anomalous behavior has been ruled out, the training dataset can be further expanded or replaced with data from the preceding month, thereby enabling a seamless and continuous update of the process. Therefore, this approach enables the early deployment of a complementary machine-learning-based control strategy, while a sufficiently long reference dataset is being collected to develop an improved solution. Moreover, the convolutional autoencoder in the time domain proves to be very stable with a short period of training.
The further characterization (section 3.5.2) using longer-term data was carried out on a single force-balance accelerometer—the one installed on the south girder of span 1, vertical axis—selected a priori as the one with the highest ambient signal-to-noise ratio. The result presented later is therefore the best resolution attainable with the present instrumentation, and the four detectors of Table 5 were compared on that same sensor.
3.5.1. Frequency-Based Clustering and Dense Neural Network Classifier
The first algorithm operates on a compact frequency-domain representation of the structural response. Each 60 s record of vertical acceleration is first screened by means of two amplitude criteria, based respectively on the root-mean-square value and on the maximum absolute value of the record, so that only ambient-vibration records are retained and train passages are discarded. The retained records are centered on their mean value and transformed into the frequency domain; the spectrum is then restricted to the 1–50 Hz band, and the eight most energetic peaks are extracted and sorted by increasing frequency. The resulting eight-component vector, which was intended as a compact signature of the dynamic behavior of the bridge at each evaluation instant, is min–max normalized before being supplied to the model.
The model is subsequently built in two stages. In the first, unsupervised stage, a k-means algorithm is applied to the set of normalized feature vectors accumulated during the reference period, which for the initially deployed model is one month of ambient records. The number of clusters was selected by means of the elbow criterion, which indicated three groups. In the second stage, given the absence of measured damage data, an equally sized set of synthetic anomalous vectors was generated from a preliminary definition of the damage signature, each inheriting the label of its parent cluster, so that the problem becomes a six-class supervised classification task comprising three normal and three anomalous states.
The classifier is a fully connected feed-forward neural network. The input layer receives eight normalized frequencies and is followed by three hidden layers with rectified linear unit (ReLU) activation comprising 192, 128 and 32 neurons, respectively. The first two hidden layers are followed by dropout layers with rates of 0.3 and 0.2, and all hidden layers are regularized with an L2 penalty of 0.0001 in order to limit overfitting given the moderate size of the training set. The output layer consists of six neurons with softmax activation, which returns the posterior probability of the analyzed record belonging to each of the six states. The network is trained with the Adam optimizer, a categorical cross-entropy loss, and a batch size of 32. The number of neurons of the first two hidden layers and the learning rate were not fixed a priori but obtained through an automated hyperparameter search based on the Hyperband algorithm, evaluated on a validation subset held out from the reference month, which retained the configuration reported above together with a learning rate of 0.001. The resulting layer configuration is summarized in Table 6.
At inference time, the normality score reported by this algorithm is the highest posterior probability among the three normal clusters, whereas the complementary anomaly score is the highest posterior probability among the three synthetic anomalous clusters. Since the input dimension is very small and the network contains fewer than 31,000 parameters, each evaluation is computationally inexpensive and is therefore performed every few seconds on the incoming records. The damage-detection capability of this approach can be improved, as described in Section 3.5.2, once longer-term data become available.
3.5.2. Sensitivity Characterization of the Frequency-Based Detector
Since no confirmed damage occurred during the operational campaign, validation against an actual in-service degraded state was not feasible. To overcome this real-world data limitation and quantitatively evaluate the detector’s resolution, a synthetic damage scenario is utilized. This resolution represents the smallest uniform reduction of deck and arch’s elastic modulus whose frequency shift the detector can effectively separate from the environmental and operational variability recorded over the year. Consequently, the resolution describes what the monitoring system is able to see, turning the central observation of the campaign into a quantitative statement. The characterization reported in this section was performed offline on the records archived over the complete campaign.
This characterization uses a revised feature computed from the full archived records: the energy-weighted centroid of the spectrum within each of eight fixed frequency bands, 0.80 Hz wide. The centroid does not change when a different line within the same resonance happens to dominate. The bands were placed on the average spectrum of all records after excluding fixed instrumental lines that were identified — 10.03 Hz, 20.07 Hz, 26.67 Hz, and 40.00 Hz. The bands were defined using records from 13 October 2024 to 13 February 2025 only and then held fixed, so that the dispersion reported below was measured on data that played no part in defining them. Table 2 gives the resulting bands, their scatter over the campaign, and the decrement produced by the reference damage scenario. These bands are tracked spectral features, not identified modes, that are found to provide the best damage-detection capability for this approach.
For this sensitivity characterization of the potential applicability of the frequency-based detector using the complete one-year monitoring dataset, the k-means stage was also omitted since the extensive data volume renders clustering unnecessary. The characterization is therefore binary, healthy against anomalous, and its classifier is the network of Section 3.5.1 with the output layer reduced to two units, 30,626 trainable parameters against 30,758. The hidden layers, regularization, and training protocol of the classifier remain unchanged, so that any improvement in performance is attributable to the feature and the larger dataset rather than to the neural network architecture.
For a linear elastic structure whose stiffness is provided by the concrete, a uniform reduction ΔE/E of the deck and arch’s elastic modulus simply scales each natural frequency by √(1 − ΔE/E). This follows analytically from the eigenvalue problem, in which a uniform reduction of the elastic modulus scales the stiffness matrix while leaving the mass matrix unchanged, so that the squared natural frequencies scale by (1 − ΔE/E) for every mode. The reference severity is ΔE/E = 5%, giving a frequency decrement of 2.532% on every band, that is, 0.16 to 0.97 Hz across the eight tracked bands (Table 2). Moreover, finite element analysis using the adjusted bridge models was performed to verify this, yielding approximately the referred 2.5% of frequency decrement on every band. Anomalous vectors are obtained by scaling measured vectors, so that the anomalous population inherits the environmental and operational dispersion of the measurements and differs from the healthy population only by the frequency decrement; no noise is added to either class, since adding it to one only would allow a classifier to separate the two by variance rather than by the shift.
For training, the severity is drawn independently for each vector from the interval 3.6%–15% instead of being fixed. A single severity would place the decision boundary through the choice of scenario, whereas sampling a range lets the dispersion of the data place it, so that the minimum detectable reduction is measured rather than chosen. The lower bound is set by the common-mode scatter reported below, and the upper bound lies well above any reduction the structure would be expected to sustain without visible distress. Localized damage was not simulated, but the recreated damage scenario is intended as a reliable validation in the absence of real damage, given the high precision later reported in this section.
Damage and temperature both act on the common-mode scale factor, the mean across bands of each vector normalized by the band means; averaging over the eight features therefore does not separate them, and it is against this factor that the damage decrement competes. Over the campaign, its standard deviation is 0.57% and its 1st-to-99th percentile band 2.12%, so the reference scenario lies 4.4 standard deviations from the mean. Three standard deviations amount to a frequency shift of 1.71%, equivalent to a uniform elastic modulus (stiffness) reduction of 3.4%: below that severity, the damage decrement is not separable from the seasonal excursion of the feature itself, whatever detector is applied. The lower end of the training interval was set at 3.6%, slightly above the 3.4% bound, so that the decrement applied to every training vector exceeds three standard deviations of the seasonal scatter. Air temperature, taken from a meteorological service since the structure carries no temperature sensors, accounts for a significant part of the variability: when regressed against a 24 h moving mean, the slope is −0.068%/°C with R² = 0.387.
The analysis uses 1,659 non-overlapping 60 s windows spanning 267 selected days of data, from 13 October 2024 to 6 October 2025. The series begins in October rather than at the start of the monitoring campaign because the remaining data after September 2025 was collected prior to closing the monitored service contracted for the renovation works. The non-overlapping windows were split 70/10/20 before any anomalous vector was generated. The min–max scaler was fitted on the healthy training records alone and applied without clipping, so that an anomalous vector falling outside the normalized range is kept as information rather than truncated.
Two split partitions are reported, because they answer different questions: what the system resolves once its baseline covers a full annual cycle, and what it would do during its first months of operation. The seasonally balanced partition groups the records into whole weeks, ranks the weeks by mean temperature, and distributes them out among the three subsets in turn, so that each subset covers the annual range; whole weeks are used so that records taken minutes apart never fall on opposite sides of a split. The chronological partition trains on the first eight months of the campaign and tests on the following four, reproducing an installation commissioned in autumn and evaluated through the next summer. The detector is then extrapolating: the two periods differ by about 10 °C in mean temperature, which at −0.068%/°C displaces the frequencies by about as much as the common-mode scatter itself, and in the same direction as damage. In both partitions, the threshold was fixed on the validation subset at a 1% target false-positive rate and applied unchanged to the test subset.
At the reference severity, with the seasonally balanced partition, the dense network separates the two populations completely: 99.4% of the healthy test records and 100% of their damaged counterparts are classified correctly, an overall accuracy of 99.7% with an area under the ROC curve of 1.000 (Table 3). Table 4 reports the detection rate as a function of severity. Taking a detection rate of 90% as the criterion, the minimum detectable uniform stiffness reduction is 1.5%, corresponding to a frequency decrement of 0.76%. The observed false-positive rate on the test subset is 0.62%, which at the measured acquisition rate of 799 accepted records per day corresponds to approximately five false alarms per day. This is smaller than the 3.6% bound established above, which is not a contradiction: that bound applies to a detector that sees only the mean shift across bands, whereas the multivariate detectors see the whole eight-band pattern. The environment displaces the eight bands unequally, mostly the lowest ones, while uniform damage displaces all of them by the same proportion, so part of the seasonal variability lies in directions that damage does not occupy. A detector restricted to the mean shift cannot cross the 90% criterion below about 3.4%, since that is the severity at which the decrement reaches three times the scatter of that quantity.
Four detectors were compared on identical partitions and an identical operating protocol (Table 5). Three of them never see a damage example: they model the healthy population and flag departures from it, which is what an installation without damage records can do. Only the dense network is trained against the synthetic damaged class.
Table 5.
Detector comparison on identical partitions and operating protocol. False alarms per day correspond to the observed false-positive rate at the measured acquisition rate of 799 records per day.
Table 5.
Detector comparison on identical partitions and operating protocol. False alarms per day correspond to the observed false-positive rate at the measured acquisition rate of 799 records per day.
| Detector | Parameters | Partition | FPR (%) | False alarms/day | Min. detectable ΔE/E (%) |
|---|---|---|---|---|---|
| Mahalanobis | 72 | balanced | 0.31 | 2.5 | 2.00 |
| Gaussian mixture | 135 | balanced | 0.31 | 2.5 | 1.75 |
| One-class SVM | 760 | balanced | 0.62 | 5.0 | 1.75 |
| Dense network | 30,626 | balanced | 0.62 | 5.0 | 1.50 |
| Mahalanobis | 72 | chronological | 2.42 | 19.3 | — |
| Gaussian mixture | 135 | chronological | 3.02 | 24.1 | — |
| One-class SVM | 760 | chronological | 1.81 | 14.5 | — |
| Dense network | 30,626 | chronological | 0.91 | 7.2 | — |
All four detectors resolve the reference scenario completely. The advantage of the dense network in resolution is modest—1.5% against 1.75% for a 135-parameter mixture model—and would not on its own justify its complexity. However, its advantage under seasonal extrapolation is substantial: with a baseline covering only eight months, it produces 7.2 false alarms per day against 14.5 to 24.1 for the one-class methods, and this is the reason to retain it. The contrast between the two partitions is itself an operational result: a baseline that does not cover a full annual cycle produces a false-alarm rate three to ten times higher when the season changes, because the seasonal decrease in frequency has the same sign as damage.
3.5.3. Convolutional Autoencoder Trained on Unsegmented Records
The second algorithm dispenses with the frequency identification stage and operates directly on the acceleration time histories. Sixty-second windows of the vertical acceleration channel are acquired at a fixed rate of one window every five minutes, without applying any amplitude-based screening, so that ambient vibration and train passages are incorporated into the training set indistinctly. Each window is truncated or zero-padded to a fixed length of 12,000 samples, corresponding to a sampling rate of 200 Hz, and is normalized using a single min–max scaler fitted over the complete reference dataset. The model discussed here was trained with 9,367 windows, corresponding to approximately one month of continuous acquisition.
The absence of any segmentation criterion is a deliberate design decision. A variant of this model restricted to ambient-vibration records was also developed and evaluated during the implementation of the system; although more sensitive to subtle changes in the ambient response, it requires the amplitude-based pre-filtering stage described in the previous frequency-domain Sections, and consequently leaves the structure unmonitored precisely during the most energetic events to which it is subjected. The generalist formulation retained here learns the ambient response and the train-passage response as two facets of the same normal behavior, which removes the pre-filtering stage from the inference pipeline and reduces the number of false alarms associated with train passages.
The model is a symmetric one-dimensional convolutional autoencoder. The encoder comprises a convolutional layer with 48 filters of kernel size 3 and ReLU activation followed by a max-pooling layer of size two, a second convolutional layer with 16 filters of the same kernel size and a second max-pooling layer. The resulting feature maps are flattened and projected onto a fully connected bottleneck of eight neurons, so that each window is compressed by a factor of 1,500. The decoder mirrors this structure: a dense layer restores the flattened representation, which is reshaped and processed by two transposed convolutional layers with 16 and 48 filters, each followed by an up-sampling layer of size two, and by a final transposed convolutional layer with a single filter and sigmoid activation that returns the reconstructed window. The complete model contains 821,801 trainable parameters and is detailed in Table 6.
Training is fully unsupervised: the network is optimized to minimize the mean squared error between each input window and its reconstruction, so that no labeled damage data are required. The dimension of the bottleneck, the number of filters of both convolutional layers, the optimizer and the learning rate were determined by an automated random search over ten configurations, evaluated on the reconstruction error of the validation subset. Once trained, the distribution of the reconstruction error over the reference dataset defines the decision rule: the anomaly threshold is set at its 95th percentile, which for the present model corresponds to a mean squared error of 0.000573. Records whose reconstruction error exceed this threshold are reported as anomalies, whereas the remaining records are assigned a normality score computed as a Gaussian kernel of the distance between their reconstruction error and the mode of the reference error distribution, the bandwidth of the kernel acting as the tolerance to normal operational variability. Because the model processes the complete waveform instead of eight scalar features, its computational cost is considerably higher, and the inference service accordingly evaluates one window every five minutes.
Both models, together with their scalers, thresholds and selected hyperparameters, are versioned in an MLflow model registry hosted in the cloud environment shown as component B in Figure 4 and are retrieved by the corresponding inference services at start-up, so that every result stored in the monitoring database is traceable to the specific training run that produced the deployed model.
Table 6.
Layer configuration of the two anomaly detection algorithms implemented in the monitoring platform. Output shapes exclude the batch dimension.
Table 6.
Layer configuration of the two anomaly detection algorithms implemented in the monitoring platform. Output shapes exclude the batch dimension.
| Stage | Layer (type and configuration) | Output shape | Parameters |
|---|---|---|---|
| (a) Frequency-based dense neural network classifier | |||
| Input | Input layer (eight normalized frequencies) | (8) | 0 |
| Hidden 1 | Dense, 192 units, ReLU, L2 = 0.0001 | (192) | 1,728 |
| Dropout, rate 0.3 | (192) | 0 | |
| Hidden 2 | Dense, 128 units, ReLU, L2 = 0.0001 | (128) | 24,704 |
| Dropout, rate 0.2 | (128) | 0 | |
| Hidden 3 | Dense, 32 units, ReLU, L2 = 0.0001 | (32) | 4,128 |
| Output | Dense, 6 units, softmax | (6) | 198 |
| Total trainable parameters | 30,758 | ||
| (b) Generalist convolutional autoencoder on unsegmented records | |||
| Input | Input layer (60 s window sampled at 200 Hz) | (12,000, 1) | 0 |
| Encoder | Conv1D, 48 filters, kernel size 3, ReLU | (12,000, 48) | 192 |
| MaxPooling1D, pool size 2 | (6000, 48) | 0 | |
| Conv1D, 16 filters, kernel size 3, ReLU | (6000, 16) | 2,320 | |
| MaxPooling1D, pool size 2 | (3000, 16) | 0 | |
| Flatten | (48,000) | 0 | |
| Bottleneck | Dense, 8 units, ReLU | (8) | 384,008 |
| Decoder | Dense, 48,000 units, ReLU | (48,000) | 432,000 |
| Reshape | (3000, 16) | 0 | |
| Conv1DTranspose, 16 filters, kernel size 3, ReLU | (3000, 16) | 784 | |
| UpSampling1D, size 2 | (6000, 16) | 0 | |
| Conv1DTranspose, 48 filters, kernel size 3, ReLU | (6000, 48) | 2,352 | |
| UpSampling1D, size 2 | (12,000, 48) | 0 | |
| Output | Conv1DTranspose, 1 filter, kernel size 3, sigmoid | (12,000, 1) | 145 |
| Total trainable parameters | 821,801 | ||
3.5.5. Comparison of the Two Approaches
Although both algorithms return a normality score and are integrated into the same monitoring platform, they differ in the nature of their input, in the learning paradigm on which they are based and in the class of anomalies that they are able to reveal. Table 7 summarizes the main differences between the two approaches.
The frequency-based approach has a clearer physical background, since its input variables are the spectral features identified from the acceleration records. Consequently, persistent changes in the normality score can be traced back to specific spectral components and, ultimately, to changes in the associated resonance bands. This interpretability, however, comes at the cost of discarding much of the information contained in the original records, including the waveform, phase and transient content, while also requiring an a priori assumption about how damage manifests itself.
The convolutional autoencoder, in contrast, makes no explicit assumption about the form of the damage. Any record that cannot be accurately reconstructed by the model is flagged as anomalous, which in principle enables the detection of changes that are not necessarily associated with frequency-domain patterns, including transient events or modifications in the measured response during train passages. This broader detection capability comes at the expense of interpretability, as the decision variable is a scalar reconstruction error with no direct physical meaning. The proposed autoencoder is particularly well suited to the present case study, which involves the renovation of the rail track under conditions in which construction works are carried out at night and railway service resumes directly afterwards. If a defect or irregularity were introduced during track installation, the subsequent passage of a train could potentially generate an abnormal impact or transient response, either during the train passage itself or at the onset of the free-vibration response after the train has left the monitored section. Such localized defects are not expected to produce a significant change in the tracked spectral features but may instead manifest as transient deviations within the continuous time-domain windows, which would appear as novel patterns in the acceleration records. The sensitivity of the force-balance accelerometers installed on the deck has been experimentally evidenced during the construction works, as the sensors were able to capture dynamic disturbances associated with workers walking on the deck and carrying out light construction activities, excluding high-impact operations such as concrete chipping. This suggests direct evidence of the capability of the instrumentation to resolve relatively small changes in the measured structural response and supports the suitability of the time-domain approach for detecting unexpected transient responses during train passages. The generalist autoencoder therefore provides a potentially valuable means of identifying unexpected responses immediately after the completion of the nighttime works once a precise baseline is established, evaluating whether the first train passages remain consistent with the learned normal behavior.
The two models should therefore be regarded as complementary rather than alternative approaches. The frequency-based approach explicitly resolves the distinct normal operating states associated with environmental variability, whereas the generalist autoencoder provides a broader novelty-detection capability across the complete operating range of the structure, including transient responses that may arise as a consequence of the renovation works. Their simultaneous deployment consequently enables a degree of cross-validation between the two diagnostic outputs, while also providing a useful complementary layer to the traditional threshold-based controls already implemented in the monitoring system. In particular, a persistent change in the distribution of the normality scores detected consistently by both models provides a substantially more robust indication of a modification in structural behavior than the output of either model considered in isolation. At the same time, an anomaly detected exclusively by the autoencoder may provide an early indication of a localized or transient novelty that does not significantly affect the identified frequency components. This additional capability could be particularly valuable for identifying possible localized issues associated with the railway infrastructure during the train passages following the nightly renovation works, although this application is beyond the scope of the structural monitoring contract, which remains centered on the bridge structure itself. No such cases were identified during the monitoring period based on acceleration levels and visual inspections at night; consequently, the ability of the autoencoder to detect such events could not be validated against measurements corresponding to actual damage.
3.5.6. Anomaly Detection User-Interface
The output of the anomaly detection algorithms is represented as a normality score assigned to each analyzed sample. Under normal operating conditions, most evaluations are expected to be concentrated within the highest normality region, whereas isolated evaluations in lower normality regions may occur owing to normal operational variability. Consequently, the population distribution over time, rather than individual isolated evaluations, constitutes the main indicator for assessing structural behavior.
Figure 16 shows the real-time evaluation histogram obtained for an incoming month of new signal using the frequency-based clustering and dense neural network classifier previously trained with one month of reference data. Most evaluations are concentrated within the region corresponding to the highest degree of normality, while the lower normality regions contain only a comparatively small population of isolated evaluations.
Figure 17 presents the results obtained using the convolutional autoencoder applied directly to the acceleration records, without previous frequency-domain transformation. After pretraining using one month of reference data acquired in March 2025, the algorithm was continuously used to evaluate the monitoring data acquired during the campaign. Compared with the frequency-based approach, the obtained distributions are more concentrated within the highest normality region for the analyzed data.
Both anomaly detection algorithms were pretrained using one month of reference data and subsequently integrated into the monitoring platform for continuous evaluation of the incoming data throughout the monitoring campaign.
3.6. Real-Time Monitoring Platform
The monitoring architecture described in the previous sections culminates in a real-time monitoring platform that integrates the geometric representation of the bridge with all the information generated throughout the monitoring process. The platform combines within a single environment the spatial location of the installed sensors, the measured variables, and the signal-processing results, providing a comprehensive overview of the structural condition.
A three-dimensional model of the bridge (Figure 18) provides the geometric context for the monitoring data, allowing users to navigate span by span while displaying the measurements associated with each instrument directly at its installation location. The displayed values can be configured to represent instantaneous measurements or statistical quantities, including minimum, maximum and average values over user-defined time intervals. In addition, the platform provides direct access to the complete monitoring database, enabling detailed consultation of both historical and real-time measurements.
Beyond the visualization of monitoring data, the platform provides interactive tools for interpreting the outputs of the anomaly detection algorithms. Rather than relying on isolated evaluations, the normality scores produced by the machine-learning models are represented as interactive density maps representing the temporal evolution of the normality-score distribution (Figure 16 and Figure 17). This representation enables the engineer to assess the overall evolution of the structural behavior while accounting for the occasional isolated evaluations that naturally arise from environmental variability and measurement uncertainty.
The interactive interface (Figure 19) allows continuous zooming from long monitoring periods down to individual events, while each cell of the distribution can be queried to obtain the corresponding evaluation density and time interval. This functionality facilitates the identification of persistent changes in the distribution of normality scores, providing a more robust basis for structural assessment than the interpretation of individual anomaly detections. Threshold-based warnings and the outputs of the machine-learning algorithms are therefore evaluated within a common operational environment, supporting engineering decision-making during continuous bridge monitoring.
The platform also includes a conversational assistant embedded in the GUI (Figure 20), whose purpose is to shorten the interval between an alert being raised and an informed decision being taken by the personnel on site during the night shifts. It is implemented as a retrieval-augmented generation (RAG) system rather than a fine-tuned model: no model weights were modified, and the whole of the domain content resides in a local knowledge base queried at inference time, so that neither the project data nor the queries leave the operator’s premises. The knowledge base combines two sources. The first is a static corpus describing the structure together with the sensor inventory, the position of each transducer in the instrumentation layout displayed by the GUI, and an account of the track renewal works and of the reason for which they are being monitored. The second is the project InfluxDB database, from which the assistant retrieves current and averaged channel values and the alert thresholds. A user may therefore ask where a given accelerometer is installed, what the mean value of a strain gauge has been over the preceding hours, or what the present state of the structure is; in the last case the assistant returns the recent means of each family of sensors, their comparison against the corresponding thresholds, and the number of alerts raised in the period. The assistant is a consultation interface and not part of the safety chain. The alerts themselves are raised by a deterministic rule engine, which operates unchanged whether or not the assistant is used; no automated action derives from its output, and every answer is traceable to the records from which it was retrieved. Its accuracy was not systematically evaluated, as no benchmark of retrieval quality or of answer correctness was established. This evaluation is left to future work.
4. Discussion
The monitoring campaign demonstrated the feasibility of implementing a continuous structural health monitoring system on a complex railway bridge under real operating conditions throughout the renewal works. The combined use of distributed sensing, automated data processing and numerical modelling provided complementary information that facilitated the interpretation of the bridge response and the identification of changes that could indicate potential issues in its structural behavior from the start of monitoring.
The comparison between the measured responses and the adjusted finite element models confirmed the plausibility of the measured response with respect to the analytical predictions. Within the analyzed monitoring period, neither the conventional threshold-based warnings (comparison of nighttime works and daytime operation responses, thresholds based on the initial monitored measurements, and model-based thresholds) nor the machine-learning algorithms used to assess changes in the dynamic features identified persistent patterns that could be associated with structural damage.
Several practical limitations should nevertheless be considered when interpreting these results. First, the monitoring campaign started after the bridge had already been in service for many years. Consequently, the available reference corresponds to the beginning of the monitoring campaign rather than to the original condition of the bridge, preventing the assessment of possible long-term degradation mechanisms that may have occurred before instrumentation. The scope of the monitoring project was therefore limited to assessing changes in the structural response during the monitored renovation and operational one-year period contracted, and was not intended to validate the original structural design and construction project, or establish the structural condition of the bridge prior to the installation of the monitoring system. Furthermore, the adopted monitoring strategy to improve safety during the renovation works does not provide direct information regarding the condition of the prestressing system. These limitations are inherent to external monitoring deployments on existing infrastructure and should be considered when interpreting the results. In any case, a detailed inspection is recommended after the works, which may include specific local tests to verify the condition of certain elements.
The implementation of machine-learning algorithms should also be interpreted within the operational context of the monitoring system. The objective of the present work was not to develop new anomaly detection algorithms but to demonstrate their integration into a continuous SHM framework. Owing to the available instrumentation and the operational conditions of the bridge, the frequency-based approaches were applied to the frequency-spectrum processing of each accelerometer independently, whereas the convolutional autoencoder operated directly on the measured acceleration time histories. This framework provided complementary anomaly detection strategies while enabling rapid deployment and adaptation to different monitoring conditions, with generalized procedures that can be transferred to new cases.
An additional aspect highlighted by this work is the interpretation of anomaly detection results. Rather than considering isolated anomalous evaluations as direct indicators of structural deterioration, the proposed workflow allows the evaluation of the temporal evolution of the population associated with different normality scores. This approach reduces the influence of isolated events caused by environmental variability or uncertainty in the identified features and provides a more robust basis for engineering assessment. The interactive monitoring platform further supports this interpretation by allowing engineers to explore the evolution of these distributions in real time.
Furthermore, a subsequent sensitivity analysis conducted over a full year of monitoring data successfully validated the long-term applicability of the system. Although the algorithms operated in real time from the onset, they were initially constrained by short-term data and required periodic retraining. While the quantitative resolution was characterized exclusively for the frequency-based approach, the train-signature detector requires just over a month of data to establish a baseline, operating as a stable novelty detector capable of identifying transient deviations from the learned structural signature. Despite this immediate nature of the initial deployment, the complete environmental cycle confirmed an excellent resolution for the spectral features, proving that the framework effectively separates seasonal variations from structural changes over extended campaigns.
Finally, the proposed monitoring architecture was conceived as a scalable framework rather than a fixed implementation. Although the present deployment reflects the available instrumentation, the same workflow can readily incorporate denser sensor networks, additional sensing technologies or more advanced feature extraction techniques, including global operational modal parameters, without requiring substantial modifications to the overall system architecture.
5. Conclusions
This paper presented the implementation and operational assessment of a real-time structural health monitoring system for the Bolueta railway bridge during its renewal works. The proposed framework integrates distributed sensing, automated data acquisition, signal processing, offline reference finite element models, machine-learning-based anomaly detection and an interactive monitoring platform within a unified operational architecture.
The comparison between measured data and numerical simulations confirmed that the monitored structural responses are physically coherent. Throughout the analyzed monitoring period, none of the monitored measurements revealed evidence of structural damage associated with the renewal works.
Machine-learning techniques were successfully integrated into the monitoring workflow to complement conventional threshold-based warning systems.
The resolution of the frequency-based approach was characterized against uniform stiffness-reduction scenarios once a full year of data became available. With the replacement of the ranked-peak descriptor by the band-tracking feature used in the sensitivity characterization, and a reference population covering a full annual cycle, the minimum detectable reduction is 1.5% of the concrete elastic modulus at a false-positive rate of 0.62%, equivalent to about 5 false alarms per day at the acquisition rate of the system. A deployment considering this target feature together with the now-available long-term reference dataset is identified as a priority for future work if the monitoring continues.
Rather than replacing engineering judgment, these algorithms provide an additional decision-support layer capable of characterizing the normal structural behavior and automatically identifying deviations from the learned reference condition. The interpretation of the temporal evolution of the normality-score distributions, instead of isolated anomaly detections, proved particularly suitable for continuous monitoring under realistic environmental variability.
The developed real-time monitoring platform further extends these capabilities by integrating measurements, dashboards, warning thresholds and machine-learning anomaly detection results within a common interactive environment. The possibility of jointly exploring monitoring data and anomaly-score distributions in real time provides valuable support for engineering interpretation and facilitates the operational use of structural health monitoring systems. The conversational assistant extends that support to non-specialist personnel: grounded on a local knowledge base that couples a description of the structure and of the track renewal works with the live project database, it answers questions on sensor location, recent sensor channel mean values and current alert status in natural language, while the alerts themselves continue to be raised by the deterministic rule engine. Its answer quality was not evaluated systematically, so it is reported as an operational feature of the platform rather than as a validated contribution, and consequently as a second priority for future work.
Although the present implementation was developed using the available instrumentation and a limited reference period for algorithm training and deployment, the proposed architecture is inherently modular and scalable. The proposed framework can readily incorporate more data, advanced feature extraction techniques, denser sensing configurations, and new machine-learning algorithms without modifying the overall system architecture. In particular, temperature compensation of the identified frequencies, deliberately not applied here so that the reported damage-detection capability includes the seasonal dispersion, represents a natural extension of the present work; this would require structural temperature measurements rather than the air temperature.
In particular, the convolutional autoencoder may provide a complementary capability for detecting localized or transient changes in the time-domain structural response, including potentially abnormal train-induced impacts occurring immediately after nighttime track-renewal works. This is particularly relevant for localized irregularities that may not produce significant changes in the identified natural frequencies. Although no abnormal train-induced impacts or persistent deviations were detected during the analyzed monitoring period, this approach could provide an additional early-warning capability after track-renewal operations, when the first train passages, and offers an immediate opportunity to assess whether the measured response remains consistent with the learned normal behavior.
Overall, the contribution of this work lies not in the development of individual sensing technologies or machine-learning algorithms, but in the validation of an integrated and scalable operational SHM architecture demonstrated on a complex railway bridge under real service conditions. This approach provides a practical basis for short and long-term monitoring of railway infrastructure and establishes a flexible framework that can evolve together with future sensing technologies and data-driven analysis methods.
6. Patents
No patents resulted from the work reported in this manuscript. The registration of a software implementation of the proposed monitoring system is currently under consideration. This does not pose any obstacle to the publication of this article.
Author Contributions
Conceptualization, D.Z-S., A.A. and M.E.; methodology, D.Z-S., A.A. and J.C.J.; software, A.A. and D.Z-S.; validation, J.C.J., J.L. and M.E.; formal analysis, J.C.J., D.Z-S. and A.A.; investigation, D.Z-S., A.A. and J.C.J.; resources, M.E. and J.L.; data curation, A.A. and J.L.; writing—original draft preparation, D.Z-S., J.C.J. and A.A.; writing—review and editing, D.Z.-S., J.C.J., A.A., J.L. and M.E.; visualization, A.A. and J.L.; supervision, M.E.; project administration, M.E.; funding acquisition, M.E. and D.Z-S. All authors have read and agreed to the published version of the manuscript. Authorship is limited to those who have contributed substantially to the work reported.
Funding
This work originated from bridge monitoring activities carried out during renovation works, involving METRO BILBAO, TECSA, and TEAM INGENIERIA. Subsequent research and development activities related to this research were supported by the European Commission under the Horizon Europe programme through the SHIFTIN project (Grant Agreement No. 101319219), the FUTURAL project (Grant Agreement No. 101083958), and the MULTICLIMACT project (Grant Agreement No. 101123538).
Data Availability Statement
The data supporting the findings of this study are not publicly available because they are owned by the infrastructure manager and concern a sensitive and operational railway infrastructure. Access to the data may be considered only upon a specific request describing the intended purpose and proposed use of the data. Each request is assessed and authorized on a case-by-case basis by TECNALIA and the infrastructure manager (METRO BILBAO), subject to applicable confidentiality and security restrictions.
Acknowledgments
The authors acknowledge METRO BILBAO, TECSA, and TEAM INGENIERIA for their involvement in the bridge monitoring activities carried out during the renovation works. The authors also acknowledge the support provided through the Horizon Europe SHIFTIN project (Grant Agreement No. 101319219), the FUTURAL project (Grant Agreement No. 101083958), and the MULTICLIMACT project (Grant Agreement No. 101123538) for subsequent research and development activities related to the work presented in this manuscript.
Conflicts of Interest
The authors declare no conflicts of interest.
References
- Brownjohn, J.M.W. Structural health monitoring of civil infrastructure. Philos. Trans. R. Soc. A 2007, 365, 589–622. [Google Scholar] [CrossRef]
- Brownjohn, J.M.W.; Magalhães, F.; Caetano, E.; Cunha, Á. Vibration-based monitoring of civil infrastructure: Challenges and successes. J. Civ. Struct. Health Monit. 2011. [Google Scholar] [CrossRef]
- He, Z.; Li, W.; Salehi, H.; Zhang, H.; Zhou, H.; Jiao, P. Integrated structural health monitoring in bridge engineering. Autom. Constr. 2022, 136, 104168. [Google Scholar] [CrossRef]
- Carden, E.P.; Fanning, P. Vibration based condition monitoring: A review. Struct. Health Monit. 2004, 3, 355–377. [Google Scholar] [CrossRef]
- Saidin, S.S.; Jamadin, A.; Kudus, S.A.; Amin, N.A.M.; Anuar, M.A. An overview: The application of vibration-based techniques in bridge structural health monitoring. Int. J. Concr. Struct. Mater. 2022, 16. [Google Scholar] [CrossRef]
- Ghahremani, B.; Enshaeian, A.; Rizzo, P. Bridge health monitoring using strain measurements and high-fidelity finite element analysis. Sensors 2022. [Google Scholar] [CrossRef]
- Maeck, J.; De Roeck, G. Dynamic bending and torsion stiffness derivation from modal curvatures and its application to damage detection. J. Sound Vib. 2003, 267, 355–370. [Google Scholar]
- He, L.; Qin, S.; Bui, T.; Reynders, E.; Cuadrado, M.; Museros, P.; De Roeck, G.; Sas, P.; Moens, D.; Jonckheere, S. Operational modal analysis of a high-speed railway bridge: The Jalon viaduct. In Proceedings of the ISMA 2012 International Conference on Noise and Vibration Engineering, Leuven, Belgium, 17–19 September 2012. [Google Scholar]
- Brownjohn, J.M.W.; Magalhães, F.; Caetano, E.; Cunha, Á. Ambient vibration re-testing and operational modal analysis of the Humber Bridge. Eng. Struct. 2010, 32, 2003–2018. [Google Scholar] [CrossRef]
- Meruane, V.; Heylen, W. Structural damage assessment under varying temperature conditions. Struct. Health Monit. 2012. [Google Scholar] [CrossRef]
- Fernández-Navamuel, A.; Magalhães, F.; Zamora-Sánchez, D.; Omella, Á. J.; Garcia-Sanchez, D.; Pardo, D. Deep learning enhanced principal component analysis for structural health monitoring. Struct. Health Monit. 2022, 21, 1710–1722. [Google Scholar] [CrossRef]
- García-Macías, E.; Ierimonti, L.; Venanzi, I.; Ubertini, F. Online surrogate-based model updating for structural health monitoring using measurement data. Int. J. Archit. Herit. 2021. [Google Scholar]
- Avci, O.; Abdeljaber, O.; Kiranyaz, S.; Hussein, M.; Gabbouj, M.; Inman, D.J. A review of vibration-based damage detection in civil structures: From traditional methods to machine learning. Mech. Syst. Signal Process. 2021. [Google Scholar] [CrossRef]
- Malekloo, A.; Ozer, E.; AlHamaydeh, M.; Girolami, M. Machine learning and structural health monitoring overview with emerging technology and high-dimensional data source highlights. Struct. Health Monit. 2022, 21, 1906–1955. [Google Scholar] [CrossRef]
- Azimi, M.; Eslamlou, A.D.; Pekcan, G. Data-driven structural health monitoring and damage detection through deep learning: State-of-the-art review. Sensors 2020. [Google Scholar] [CrossRef]
- Zinno, R.; Haghshenas, S.; Guido, G.; Vitale, A.; Sarhadi, A. The state of the art of artificial intelligence approaches and new technologies in structural health monitoring of bridges. Appl. Sci. 2023, 13, 97. [Google Scholar] [CrossRef]
- Indhu, R.; Sundar, G.R.; Parveen, H.S. A review of machine learning algorithms for vibration-based SHM and vision-based SHM. In Proceedings of the Second International Conference on Artificial Intelligence and Smart Energy (ICAIS), Coimbatore, India, 23–25 February 2022. [Google Scholar]
- Fernández-Navamuel, A.; Zamora-Sánchez, D.; Omella, Á.J.; Pardo, D.; García-Sánchez, D.; Magalhães, F. Supervised deep learning with finite element simulations for damage identification in bridges. Eng. Struct. 2022, 257, 114016. [Google Scholar] [CrossRef]
- Sonbul, O.; Rashid, M. Towards the structural health monitoring of bridges using wireless sensor networks: A systematic study. Sensors 2023, 23, 8468. [Google Scholar] [CrossRef]
- Armijo, A.; Zamora-Sánchez, D. Integration of railway bridge structural health monitoring into the Internet of Things with a digital twin: A case study. Sensors 2024, 24, 2115. [Google Scholar] [CrossRef]
- Xie, Y.; Meng, X.; Nguyen, D.T.; Xiang, Z.; Ye, G.; Hu, L. A discussion of building a smart SHM platform for long-span bridge monitoring. Sensors 2024, 24, 3163. [Google Scholar] [CrossRef]
- Hu, X.; Assaad, R.H.; Ravishankar, S.; Prakash, S.; Lin, J. Developing digital twins for real-time bridge structural health monitoring by integrating Scan-to-BrIM remote sensing technologies, photogrammetry-based 3D scanning, finite element modeling, and IoT sensing. Proceedings of Computing in Civil Engineering 2024, Pittsburgh, PA, USA, 2024; pp. 455–465. [Google Scholar]
- Jeong, S.; Law, K.H. A scalable cloud-based cyberinfrastructure platform for bridge monitoring. Struct. Infrastruct. Eng. 2019, 15, 82–102. [Google Scholar] [CrossRef]
- Vander Horn, E.; Mahadevan, S. Digital twin: Generalization, characterization and implementation. Decis. Support Syst. 2021, 145, 113524. [Google Scholar] [CrossRef]
- Chiachío, M.; Megía, M.; Chiachío, J.; Fernández, J.; Jalón, M.L. Structural digital twin framework: Formulation and technology integration. Autom. Constr. 2022, 140, 104333. [Google Scholar] [CrossRef]
- Proyecto de Liquidación de la Obra Civil del Tramo Bolueta–Etxebarri del Ferrocarril Metropolitano de Bilbao. Planos 2003.
- Zamora-Sánchez, D.; Armijo, A.; Lucena, J.; Jiménez, J.C.; Ezquerro, M.; Orbe, A.; Piñero, I. Continuous Structural Monitoring of a Singular Bridge under Rail Track Renovation Works Using Data Analysis, AI-Based Anomaly Detection and Comparative Finite Element Models. In Proceedings of the Construction Pathology, Rehabilitation Technology and Heritage Management Conference, Bilbao, Spain, 26–29 May 2026. [Google Scholar]
- Proyecto de Liquidación de la Obra Civil del Tramo Bolueta–Etxebarri del Ferrocarril Metropolitano de Bilbao. In Memoria y Anejos. Anejo No. 2: Prueba de Carga de las Estructuras; July 2003.
- CEN. Eurocode EN 1990: Basis of structural design; European Committee for Standardization, 2002. [Google Scholar]
- Ferreira, G.; Montenegro, P.; Andersson, A.; Henriques, A.; Karoumi, R.; Calçada, R. Critical Analysis of the Current Eurocode Deck Acceleration Limit for Evaluating Running Safety in Ballastless Railway Bridges. Eng. Struct. 2024, 312, 118127. [Google Scholar] [CrossRef]
- Sadeghi Eshkevari, S. Artificial Intelligence-Aided Strategies for Structural Health Monitoring and Control. Ph.D. Dissertation, Lehigh University, Bethlehem, PA, USA, 2024. [Google Scholar]
- Farrar, C.R.; Doebling, S.W.; Cornwell, P.J.; Straser, E.G. Variability of Modal Parameters Measured on the Alamosa Canyon Bridge. In Proceedings of the 15th International Modal Analysis Conference (IMAC XV), Orlando, FL, USA, 3–6 February 1997; pp. 257–263. [Google Scholar]
- Peeters, B.; De Roeck, G. One-Year Monitoring of the Z24-Bridge: Environmental Effects versus Damage Events. Earthq. Eng. Struct. Dyn. 2001, 30, 149–171. [Google Scholar] [CrossRef]
Figure 1.
Elevation and plan view of the Bolueta railway bridge. The bridge consists of five double-box-girder spans (22.0 + 24.5 + 24.5 + 24.5 + 24.0 m), a 63.0 m twin-rib arch crossing the Nervión River, and a 19.5 m transition span connecting the bridge with the adjacent tunnel. Adapted from the project drawings [26] by Fulcrum Ingeniería and the bridge designers Leonardo Fernández Troyano and Javier Manterola Armisén.
Figure 1.
Elevation and plan view of the Bolueta railway bridge. The bridge consists of five double-box-girder spans (22.0 + 24.5 + 24.5 + 24.5 + 24.0 m), a 63.0 m twin-rib arch crossing the Nervión River, and a 19.5 m transition span connecting the bridge with the adjacent tunnel. Adapted from the project drawings [26] by Fulcrum Ingeniería and the bridge designers Leonardo Fernández Troyano and Javier Manterola Armisén.

Figure 2.
Instrumentation layout and location of the acquisition cabinets. Sensor locations were defined according to the expected structural behavior of the bridge, accessibility constraints, and cable routing from the acquisition cabinets. Force-balance and MEMS accelerometers were distributed to monitor structural acceleration levels and identify the bridge eigenfrequencies, whereas strain gauges, inclinometers and linear displacement potentiometers were installed to monitor flexural strains, deck rotations and bearing displacements, respectively.
Figure 2.
Instrumentation layout and location of the acquisition cabinets. Sensor locations were defined according to the expected structural behavior of the bridge, accessibility constraints, and cable routing from the acquisition cabinets. Force-balance and MEMS accelerometers were distributed to monitor structural acceleration levels and identify the bridge eigenfrequencies, whereas strain gauges, inclinometers and linear displacement potentiometers were installed to monitor flexural strains, deck rotations and bearing displacements, respectively.

Figure 3.
(a) Representative view of the underside of a span in the double-box girder section, showing the locations of the installed accelerometers and the strain monitoring system at mid-span. (b) Detail of a half-Wheatstone-bridge strain gauge installation after applying protective coverings, and of an ambient accelerometer installed near mid-span on a custom-made steel support.
Figure 3.
(a) Representative view of the underside of a span in the double-box girder section, showing the locations of the installed accelerometers and the strain monitoring system at mid-span. (b) Detail of a half-Wheatstone-bridge strain gauge installation after applying protective coverings, and of an ambient accelerometer installed near mid-span on a custom-made steel support.

Figure 4.
Real-time monitoring system architecture implemented for the Bolueta railway bridge. The system comprises the sensing layer, edge data acquisition, MQTT-based communication through the 4G network, and three functional environments: (A) an on-premises infrastructure based on Node-RED for data ingestion, initial processing, and storage of time-stamped measurements; (B) a cloud infrastructure supporting scalable storage, batch processing, and machine-learning services; and (C) a Digital Twin environment, whose functionalities can be extended depending on the features deployed. For this case study, this layer incorporates graphical contextualization, interactive histograms of unsupervised machine-learning-based anomaly detection, and a chatbot assistant. This monitoring architecture framework was first introduced by the authors for bridges in a previous limited application [20].
Figure 4.
Real-time monitoring system architecture implemented for the Bolueta railway bridge. The system comprises the sensing layer, edge data acquisition, MQTT-based communication through the 4G network, and three functional environments: (A) an on-premises infrastructure based on Node-RED for data ingestion, initial processing, and storage of time-stamped measurements; (B) a cloud infrastructure supporting scalable storage, batch processing, and machine-learning services; and (C) a Digital Twin environment, whose functionalities can be extended depending on the features deployed. For this case study, this layer incorporates graphical contextualization, interactive histograms of unsupervised machine-learning-based anomaly detection, and a chatbot assistant. This monitoring architecture framework was first introduced by the authors for bridges in a previous limited application [20].

Figure 5.
Comparison of the first global vibration mode predicted by the two independent three-dimensional finite element models developed using different modelling approaches. (a) First natural mode, predominantly lateral with a minor vertical component, predicted by the ANSYS solid model (2.00 Hz) using the original design material properties. (b) Corresponding first natural mode predicted by the equivalent SAP2000 shell model (2.03 Hz), demonstrating the consistency between the two independent modelling approaches.
Figure 5.
Comparison of the first global vibration mode predicted by the two independent three-dimensional finite element models developed using different modelling approaches. (a) First natural mode, predominantly lateral with a minor vertical component, predicted by the ANSYS solid model (2.00 Hz) using the original design material properties. (b) Corresponding first natural mode predicted by the equivalent SAP2000 shell model (2.03 Hz), demonstrating the consistency between the two independent modelling approaches.

Figure 6.
Selected vibration modes with appreciable vertical response and the highest relevant modal mass participation factors predicted by the adjusted ANSYS solid model: (a) 3.9 Hz (vertical relative modal participation = 1.00); (b) 6.2 Hz (longitudinal relative modal participation = 0.88); and (c) 8.9 Hz (vertical relative modal participation = 0.58; longitudinal relative modal participation = 1.00).
Figure 6.
Selected vibration modes with appreciable vertical response and the highest relevant modal mass participation factors predicted by the adjusted ANSYS solid model: (a) 3.9 Hz (vertical relative modal participation = 1.00); (b) 6.2 Hz (longitudinal relative modal participation = 0.88); and (c) 8.9 Hz (vertical relative modal participation = 0.58; longitudinal relative modal participation = 1.00).

Figure 10.
Representative strain measurements showing that the strain increments generated during the nighttime maintenance works remained within the range recorded during normal daytime railway operation and were fully recoverable after the excitation ceased. The ordinate axis represents microstrain (με), while the abscissa shows the date and time as displayed in the monitoring platform. Screenshot of the online InfluxDB dashboard included in the real-time monitoring system architecture.
Figure 10.
Representative strain measurements showing that the strain increments generated during the nighttime maintenance works remained within the range recorded during normal daytime railway operation and were fully recoverable after the excitation ceased. The ordinate axis represents microstrain (με), while the abscissa shows the date and time as displayed in the monitoring platform. Screenshot of the online InfluxDB dashboard included in the real-time monitoring system architecture.

Figure 11.
Time series of the strain measured by the sensors installed on the north girder, along with the ambient temperature during the month of February 2025, which is analyzed separately because the system issued warning messages during that month. The left ordinate represents the strain (με), the right ordinate represents the ambient temperature (°C), and the abscissa the monitoring date. The strain measurements (solid lines) clearly encompass the variations in ambient temperature (dotted line).
Figure 11.
Time series of the strain measured by the sensors installed on the north girder, along with the ambient temperature during the month of February 2025, which is analyzed separately because the system issued warning messages during that month. The left ordinate represents the strain (με), the right ordinate represents the ambient temperature (°C), and the abscissa the monitoring date. The strain measurements (solid lines) clearly encompass the variations in ambient temperature (dotted line).

Figure 12.
Comparison of representative filtered strain measurements obtained during the monitoring campaign. (a) Initial stage; (b) final stage. No significant differences were observed in the strain response associated with train passages.
Figure 12.
Comparison of representative filtered strain measurements obtained during the monitoring campaign. (a) Initial stage; (b) final stage. No significant differences were observed in the strain response associated with train passages.

Figure 13.
Representative inclination measurements during successive train passages. The measurements are shown with respect to the inclinometer installation angle. The ordinate represents inclination in millidegrees (m°), while the abscissa shows the monitoring date and time. The inclination consistently returned to its initial value after each train passage, indicating the absence of residual or cumulative rotation. Screenshot of the online InfluxDB dashboard included in the real-time monitoring system architecture.
Figure 13.
Representative inclination measurements during successive train passages. The measurements are shown with respect to the inclinometer installation angle. The ordinate represents inclination in millidegrees (m°), while the abscissa shows the monitoring date and time. The inclination consistently returned to its initial value after each train passage, indicating the absence of residual or cumulative rotation. Screenshot of the online InfluxDB dashboard included in the real-time monitoring system architecture.

Figure 14.
Evolution of the three target vertical natural frequencies identified from 36 randomly selected 1-hour service records (sampled at 200 Hz) distributed over the 9-month monitoring period for comparison with the finite element models.
Figure 14.
Evolution of the three target vertical natural frequencies identified from 36 randomly selected 1-hour service records (sampled at 200 Hz) distributed over the 9-month monitoring period for comparison with the finite element models.

Figure 16.
Evaluation histogram obtained using the frequency-based approach with a month of reference data based on the identified frequency-domain features. The figure shows one month of monitoring data, following the standard display format of the monitoring platform. The horizontal axis represents the evaluation date, the vertical axis the normality score (%), and the color scale the evaluation density. Under normal operating conditions, most evaluations are concentrated within the highest normality region, whereas the lower normality regions contain only a comparatively small population of isolated evaluations. The pretrained algorithm produces isolated positive detections under normal conditions; therefore, the evolution of the number of positive detections over time is more relevant than individual detections.
Figure 16.
Evaluation histogram obtained using the frequency-based approach with a month of reference data based on the identified frequency-domain features. The figure shows one month of monitoring data, following the standard display format of the monitoring platform. The horizontal axis represents the evaluation date, the vertical axis the normality score (%), and the color scale the evaluation density. Under normal operating conditions, most evaluations are concentrated within the highest normality region, whereas the lower normality regions contain only a comparatively small population of isolated evaluations. The pretrained algorithm produces isolated positive detections under normal conditions; therefore, the evolution of the number of positive detections over time is more relevant than individual detections.

Figure 17.
Results obtained using the convolutional autoencoder applied directly to the acceleration time histories. The model was pretrained using one month of reference data acquired in March 2025. The figure shows one month of monitoring data, following the standard display format of the monitoring platform. The horizontal axis represents the evaluation date, the vertical axis the normality score (%), and the color scale the evaluation density. For the analyzed data, the resulting normality-score distributions remain predominantly concentrated within the highest normality region.
Figure 17.
Results obtained using the convolutional autoencoder applied directly to the acceleration time histories. The model was pretrained using one month of reference data acquired in March 2025. The figure shows one month of monitoring data, following the standard display format of the monitoring platform. The horizontal axis represents the evaluation date, the vertical axis the normality score (%), and the color scale the evaluation density. For the analyzed data, the resulting normality-score distributions remain predominantly concentrated within the highest normality region.

Figure 18.
Real-time monitoring platform integrating the three-dimensional representation of the bridge (sample of span 2) with the monitoring variables displayed at the corresponding sensor locations.
Figure 18.
Real-time monitoring platform integrating the three-dimensional representation of the bridge (sample of span 2) with the monitoring variables displayed at the corresponding sensor locations.

Figure 19.
Interactive visualization of the anomaly detection results. The horizontal axis represents the evaluation date, the vertical axis the normality score (%), and the color scale the evaluation density. The platform allows continuous zooming by adjusting the aggregation periods over any monitoring period, as well as interactive inspection of each cell of the distribution, facilitating the identification of persistent changes in structural behavior accounting for the classified events in terms of population.
Figure 19.
Interactive visualization of the anomaly detection results. The horizontal axis represents the evaluation date, the vertical axis the normality score (%), and the color scale the evaluation density. The platform allows continuous zooming by adjusting the aggregation periods over any monitoring period, as well as interactive inspection of each cell of the distribution, facilitating the identification of persistent changes in structural behavior accounting for the classified events in terms of population.

Figure 20.
Conversational assistant embedded in the monitoring GUI, configured for a Spanish speaker as per the implemented service use case. The user requests the current state of the structure; the assistant retrieves the recent channel means from the project database, compares them with the alert thresholds, and returns a summary together with the number of alerts raised in the preceding hours. Retrieval is performed against a local knowledge base, and the alert log itself is produced by a deterministic rule engine running on the database rather than generated by the assistant.
Figure 20.
Conversational assistant embedded in the monitoring GUI, configured for a Spanish speaker as per the implemented service use case. The user requests the current state of the structure; the assistant retrieves the recent channel means from the project database, compares them with the alert thresholds, and returns a summary together with the number of alerts raised in the preceding hours. Retrieval is performed against a local knowledge base, and the alert log itself is produced by a deterministic rule engine running on the database rather than generated by the assistant.

Table 2.
Tracked resonance bands of the revised feature, their scatter over the campaign, and the frequency decrement produced by the reference damage scenario.
Table 2.
Tracked resonance bands of the revised feature, their scatter over the campaign, and the frequency decrement produced by the reference damage scenario.
| Band (Hz) | Centroid (Hz) | σ/f (%) | Δf at ΔE/E = 5% (Hz) |
|---|---|---|---|
| 6.08 – 6.88 | 6.436 | 2.08 | 0.163 |
| 7.72 – 8.52 | 8.091 | 1.21 | 0.205 |
| 9.35 – 10.15 | 9.746 | 1.46 | 0.247 |
| 12.60 – 13.40 | 12.992 | 0.86 | 0.329 |
| 21.85 – 22.65 | 22.208 | 0.36 | 0.562 |
| 26.28 – 27.08 | 26.652 | 0.39 | 0.675 |
| 31.75 – 32.55 | 32.123 | 0.34 | 0.813 |
| 38.10 – 38.90 | 38.480 | 0.18 | 0.974 |
Table 3.
Confusion matrix of the dense network at ΔE/E = 5%, seasonally balanced partition, on the 322 healthy test records and their 322 scaled counterparts.
Table 3.
Confusion matrix of the dense network at ΔE/E = 5%, seasonally balanced partition, on the 322 healthy test records and their 322 scaled counterparts.
| Test records | Classified as normal | Classified as anomalous |
|---|---|---|
| Measured (normal) | 99.4% | 0.6% (false positives) |
| Synthetic, ΔE/E = 5% | 0.0% (missed detections) | 100.0% |
Table 4.
Detection rate of the dense network as a function of the severity of a uniform reduction of the concrete elastic modulus, obtained by scaling the measured test records by √(1 − ΔE/E).
Table 4.
Detection rate of the dense network as a function of the severity of a uniform reduction of the concrete elastic modulus, obtained by scaling the measured test records by √(1 − ΔE/E).
| ΔE/E (%) | Δf/f (%) | Detected as anomalous (%) |
|---|---|---|
| 0 (measured) | 0 | 0.62 (false positives) |
| 1 | −0.50 | 66.15 |
| 2 | −1.01 | 100.00 |
| 3 | −1.51 | 100.00 |
| 5 (reference) | −2.53 | 100.00 |
| 10 | −5.13 | 100.00 |
| 20 | −10.56 | 100.00 |
Table 7.
Comparison of the two anomaly detection approaches. The frequency-based approach is reported in two configurations: the one for early deployment on the platform and the one used for the sensitivity characterization of Section 3.5.2 for the complete campaign.
Table 7.
Comparison of the two anomaly detection approaches. The frequency-based approach is reported in two configurations: the one for early deployment on the platform and the one used for the sensitivity characterization of Section 3.5.2 for the complete campaign.
| Characteristic | Dense neural network | Convolutional autoencoder |
|---|---|---|
| Model input | As per 3.5.1: Eight dominant spectral peaks in the 1–50 Hz band (frequency domain). As per 3.5.2: Eight dominant spectral bands (0.8 Hz width) | Complete 60 s acceleration window, 12,000 samples (time domain) |
| Record selection | Amplitude-based pre-filtering; ambient vibration only | None; ambient vibration and train passages indistinctly |
| Feature extraction | 3.5.1: Spectral transform of each 60 s record, followed by the eight most energetic peaks sorted by frequency. 3.5.2: Energy-weighted centroid of eight fixed resonance bands | Learned by the convolutional layers |
| Learning paradigm | 3.5.1: Unsupervised clustering (k-means, k = 3) followed by supervised classification into six classes. 3.5.2: Supervised binary classification, healthy against anomalous | Unsupervised reconstruction of the normal response |
| Assumption on damage | 3.5.1: Adjustable synthetic frequency shift. 3.5.2: Uniform stiffness-reduction scenario | Not required |
| Network architecture | Fully connected, 8–192–128–32–6, ReLU, dropout, L2 regularization, softmax output | One-dimensional convolutional autoencoder, 48 and 16 filters, latent dimension 8, mirrored decoder, sigmoid output |
| Trainable parameters | 30,758 | 821,801 |
| Loss function | Categorical cross-entropy | Mean squared reconstruction error |
| Hyperparameter search | Hyperband (hidden layer sizes, learning rate) | Random search (latent dimension, filters, optimizer, learning rate) |
| Decision variable | Posterior class probability | Reconstruction error compared with the 95th-percentile threshold |
| Normality score | Highest posterior probability among the three normal clusters | Gaussian kernel of the distance to the mode of the reference error distribution |
| Evaluation rate | One evaluation every few seconds | One evaluation every five minutes |
| Interpretability | High; the input features are identified frequencies | Low; the latent features have no direct physical meaning |
| Main strength | Physical traceability of the detected change | Detection of arbitrary novelties over the whole operating range |
| Main limitation | Blind during train passages; sensitive to errors in peak identification | Large and representative reference dataset required |
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.
Copyright: This open access article is published under a Creative Commons CC BY 4.0 license, which permit the free download, distribution, and reuse, provided that the author and preprint are cited in any reuse.