Submitted:
22 November 2026
Posted:
25 November 2026
You are already at the latest version
Abstract
A single-sensor method for reconstructing cutting-force and displacement fields in thin-walled cylindrical-shell milling employs a pointwise force–displacement map obtained from a damped modal equation. This note examines the dynamic consistency of that step. The harmonic-response expression used to construct the map is exact as a particular steady-state response for constant-amplitude harmonic excitation, but a time-varying or sampled force generally generates additional transient terms. A finite moving-force pulse provides an explicit counterexample: the applied force vanishes at a sampling instant while a modal displacement remains nonzero by continuity. An exact zero-order-hold realization shows that the measured displacement depends causally on the preceding force samples and the initial modal state. The resulting input–output operator is generally lower triangular across time, and the diagonal pointwise inversion does not follow from the underlying dynamics. The analysis identifies the additional modeling and identifiability requirements for consistent single-sensor force reconstruction without excluding efficient causal implementations.
Keywords:
inverse force reconstruction
; modal dynamics
; thin-walled cylindrical shells
; moving loads
; dynamic memory
; single-sensor measurement
MSC: 70J35; 65R32
1. Introduction
The reconstruction of cutting forces and deformation fields during the milling of thin-walled cylindrical shells is difficult because the load location moves while only limited displacement measurements may be available. Chen et al. [1] proposed a physics-based, single-sensor method using analytical shell modes and a force–displacement map. The method is attractive because it seeks to avoid a spatial sensor array and to enable real-time force estimation.
The present note addresses a specific consistency question: does the second-order modal differential equation used in that method imply the instantaneous force–displacement relation subsequently inverted at each sampling time? This matters independently of the accuracy of the analytical mode shapes. The key distinction is between the frequency response to a sustained harmonic input and the transient response to a sequence of varying force amplitudes. In a dynamical structure, previous force values generally affect the displacement measured at the current instant [2,3].
The discussion concerns Equations (27)–(32) in Chen et al. [1]. We first identify the harmonic-response assumption underlying the local formula, then exhibit a finite-pulse counterexample within the moving-load setting. Finally, we write an exact sampled-data relation that retains the modal state and force history. This yields a constructive basis for a dynamically consistent inverse problem.
2. Harmonic Response and the Missing Transient
The modal equation in Equation (27) of [1], after collecting its mode-dependent constants, has the representative form
where is a natural frequency, is the modal damping ratio, collects the spatial coupling coefficient, and the sine factor represents the moving load. One of the two orthogonal circumferential modal components is displayed; the companion cosine component obeys the same type of equation. The argument below applies to each component.
For a constant amplitude , the forced periodic particular solution has the familiar form
with the phase determined by the damped frequency response (away from an undamped resonance). A complete solution additionally contains a homogeneous term fixed by the initial displacement and velocity. Equation (28) in [1] inserts the sampled amplitude into an expression of the form (2) and uses it in the pointwise map of Equation (30).
To see the distinction for variable amplitudes, put , where a and are constants. Direct differentiation yields
The terms containing and are absent from the assumed fixed-amplitude harmonic balance. Thus an instantaneous substitution does not, in general, preserve Equation (1). Treating the amplitudes as piecewise constant avoids differentiating the jumps inside each open sampling interval, but it does not remove the homogeneous response carried over from previous intervals.
3. A Moving-Force Pulse Counterexample
Proposition 1.
Consider Equation (1) with , , , and zero initial modal displacement and velocity. There exist a phase , a nonzero amplitude , and a sampling-aligned pulse
for which . Consequently, a field reconstruction that is pointwise proportional to the current value cannot represent the exact modal response for all such loading histories.
Proof.
Let . The causal impulse response of the scalar modal equation is
For the zero initial state and the pulse (4), variation of constants gives
Choose . Since as , the small-duration expansion is
It is nonzero for all sufficiently small . The force has a finite jump at T, so no impulsive force acts on the mode and the state variables and remain continuous. Hence . The sample interval can be selected so that . Equation (30) of [1], interpreted as an exact instantaneous field relation, instead predicts zero displacement everywhere when . This contradicts the surviving modal response. □
The proposition is an existence counterexample, not a claim that every force pulse produces a nonzero reading at every sensor. A sensor may lie at a modal node, and several modal contributions may cancel at particular instants. Nevertheless, a nonzero excited modal coordinate cannot generate an identically zero displacement field when the retained mode shapes are independent. The pointwise reconstruction is therefore not an identity of the underlying dynamic model. The distinction between the instantaneous reconstruction and the residual modal response after force removal is illustrated schematically in Figure 1.
4. An Exact Causal Sampled-Data Relation
The appropriate discrete relation follows directly from the same modal equation. Define the modal state . Then
The moving-load coefficient remains time dependent. Let and interpret the force sequence as a zero-order hold, for . The exact state update is
Iteration gives
For a fixed sensor position p, let be the radial mode-shape coefficient and let . With a finite modal truncation, the sensor displacement therefore satisfies the exact identity
In particular, the displacement sampled at depends on force samples over the intervals and on the initial modal state. If the output is sampled at the beginnings of these intervals, the corresponding matrix is strictly lower triangular under this convention: a force newly applied at cannot instantaneously change displacement .
Equation (11) provides a precise counterpart to the memoryless formula. After stacking sensor outputs and forces, the resulting force-to-displacement matrix is causal and generally lower triangular; its off-diagonal terms encode residual vibrations excited by previous force samples. Thus the diagonal inversion in Equation (32) of [1] does not follow from the modal differential equation without additional approximations or assumptions that suppress dynamic memory.
The replacement by a causal operator does not rule out real-time single-sensor estimation. If the modal parameters and initial state are known or estimated, and if the relevant input–output map is sufficiently informative and well conditioned, a force sequence can in principle be recovered through sequential inversion, state estimation, or suitably regularized deconvolution [4]. For example, the update (9) has fixed state dimension under a fixed modal truncation, and an efficient recursive implementation may be possible. Its identifiability, noise amplification, and computational complexity require separate analysis; the pointwise division inferred from a diagonal map is not established by Equation (27).
5. Conclusions
The mathematical issue is localized to the transition from the damped modal dynamics of Equation (27) to the instantaneous force–displacement mapping in Equations (28)–(32) of Chen et al. [1]. A fixed-amplitude harmonic particular response does not describe arbitrary force histories, and a finite moving-load pulse leaves nonzero structural displacement after the force has vanished. The exact sampled-data model retains this memory through the modal state and the earlier force samples.
A dynamically consistent reconstruction can still exploit the paper’s analytical shell modes and a single displacement sensor. It must, however, represent the transient input–output dynamics and address observability or invertibility at the selected sensor position. The pointwise diagonal relation may serve as a quasi-steady approximation under an appropriately justified time-scale separation; its general validity as an exact dynamic reconstruction formula does not follow from the stated model.
Funding
This research received no external funding.
Institutional Review Board Statement
Not applicable.
Informed Consent Statement
Not applicable.
Data Availability Statement
The results are analytical. No new experimental or numerical datasets were generated.
Conflicts of Interest
The author declares no conflicts of interest.
References
- Chen, J.; Ma, H.; Song, Q.; Cai, Y.; Liu, Z. Single-sensor-based reconstruction of force and displacement fields for thin-walled cylindrical shells milling. Int. J. Mach. Tools Manuf. 2025, 208, 104282. [Google Scholar] [CrossRef]
- Inman, D.J. Engineering Vibration, 4th ed.; Pearson: Upper Saddle River, NJ, USA, 2014. [Google Scholar]
- Ewins, D.J. Modal Testing: Theory, Practice and Application, 2nd ed.; Research Studies Press: Baldock, UK, 2000. [Google Scholar]
- Hansen, P.C. Discrete Inverse Problems: Insight and Algorithms; SIAM: Philadelphia, PA, USA, 2010. [Google Scholar] [CrossRef]
Figure 1.
Schematic of the inconsistency between a memoryless, pointwise force–displacement map and a damped modal response to a finite force pulse. The drawing illustrates the mathematical argument; it does not represent a new simulation or measurement.
Figure 1.
Schematic of the inconsistency between a memoryless, pointwise force–displacement map and a damped modal response to a finite force pulse. The drawing illustrates the mathematical argument; it does not represent a new simulation or measurement.

Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
Copyright: This open access article is published under a Creative Commons CC BY 4.0 license, which permit the free download, distribution, and reuse, provided that the author and preprint are cited in any reuse.