Submitted:
23 November 2026
Posted:
24 November 2026
You are already at the latest version
Abstract
Flank wear is measured only at periodic inspections because measurement interrupts machining, leaving the wear of intermediate cuts unknown. Existing methods fill these gaps with assumed wear values before training, and whether their per-cut estimates match actual wear is rarely tested. This study asks whether wear changes measured between inspections suffice to train a per-cut wear estimator, and when sensor signals add value. A gated recurrent unit predicts each cut's wear increase from sensor signals and is trained only on the measured change over each inspection interval. In 28 hard-turning runs measured after every cut, five-cut inspections were simulated and withheld measurements used for scoring. For cutting conditions excluded from training, estimates made during machining had a root mean square error of 4.4 µm, about 3% of final wear, against 6.1 µm without sensors and 4.6–4.8 µm when trained on assumed wear values. The estimates followed the wear-rate trend, not cut-to-cut variation. A post hoc analysis suggested that sensors helped most in the first inspection interval of a new tool under an unseen condition, before its wear rate was measured; afterwards, rate extrapolation was as accurate. Measured-interval supervision is feasible, and the value of sensors depends on the inspection history.
Keywords:
cutter flank wear
; sparse inspections
; measured-interval supervision
; online wear estimation
; unseen cutting conditions
; sensor signals
; sequence learning
1. Introduction
Progressive flank wear of the cutting tool affects cutting forces, vibration, surface integrity and dimensional accuracy, so its estimation supports both machining quality and tool-replacement decisions. Measuring flank wear requires access to the cutting edge and interrupts machining for inspection, tool handling and repositioning. Inspection is therefore performed periodically, whereas force, vibration and computer numerical control (CNC) operating signals can be recorded during every cut [1,2]. Between inspections the wear is unknown: a measured wear change gives the total increase over an inspection interval but not how it developed from cut to cut, so a tool may be replaced too early or too late. Estimating this progression is hardest for a new tool, whose own wear rate has not yet been measured, and for a cutting condition absent from the training data, when only the measurements and signals available up to the current cut can be used.
Published studies handle sparse wear measurements in four ways, summarized below and in Table 1.
The first approach fills the unmeasured cuts before training. Spline, piecewise cubic Hermite, Gaussian-process, empirical-curve or physics-guided wear values are created between measurements and used as per-cut targets [3,4,5,6]. Semi-supervised methods use unlabeled cuts together with the few measured ones, through pseudo-labels for wear regression [7] or entropy-based training for wear-state prediction under unseen cutting conditions [8]. In both cases the intermediate values come from an assumed curve or from the model itself, not from measurement, so it remains open whether the resulting per-cut estimates agree with wear actually measured at those cuts.
The second approach predicts wear only where it is measured. In the Prognostics and Health Management Asia-Pacific (PHM-AP) 2025 challenge, the six training tools have physical wear measurements only after every fifth cut [2]. Mielgo et al. used features aggregated over these five-cut intervals [9], while Kunte and Manakari predicted wear differences between inspected cuts [10]. Both use measured changes as targets, but their reported scores concern inspected cuts under one cutting condition and do not show how well a model estimates the wear of each intervening cut.
The third approach constrains the wear sequence. Monotonic and physics-informed models restrict the shape of the predicted wear curve or combine forces and wear laws with learning [11,12,13,14,15]. In the studies reviewed here, these models rely on a target at each predicted position or on additional physical information, such as forces, temperatures or calibrated wear coefficients, which periodic inspection alone does not provide.
The fourth approach learns from aggregate observations. General methods train predictors for individual instances from targets that are known only for groups, such as means, sums or differences [16,17,18]. Javanmard et al. compared two ways of doing so [19]: a bag-level loss, which fits only the group total, and an instance-level loss, which gives every member an equal share of that total. Temporal disaggregation solves a related problem, estimating a fine-interval series from interval totals with the help of related series [20,21]. In this study, the cuts between two inspections form the group: the measured-interval loss is a bag-level loss, and the equal-split baseline is the corresponding instance-level loss. Flank wear adds conditions that these general methods do not include: the cuts are ordered, each wear increment is non-negative, cumulative wear must restart from each physical measurement, and the estimates should be checked against wear measured at individual cuts. To our knowledge, learning from interval totals has not been tested under these conditions.
Together, these studies leave a gap for periodic tool inspection: none of the reviewed methods is trained only on wear changes measured between inspections and also checked against wear measured at every cut, and it is unclear when machining signals add information beyond the inspections themselves.
This study addresses this gap. A gated recurrent unit (GRU) predicts a non-negative wear increment for each cut from that cut’s signal features. During training, the predicted increments are summed over each inspection interval and compared with the measured wear change, so no intermediate wear values are assumed. The main contribution is a measured-interval learning formulation for per-cut flank-wear estimation that avoids assigning assumed wear values to unmeasured cuts. Although the GRU architecture and aggregate loss are established techniques, their application to non-negative wear increments, combined with online estimation from physical inspection measurements and direct validation against withheld per-cut wear, provides a practical approach to learning from sparse wear observations. The direct validation uses a hard-turning dataset in which wear was measured after every cut: inspections were simulated, and the withheld measurements were used only for scoring. Cutting conditions excluded from training are called unseen conditions below, and estimates made during machining, using only data up to the current cut, are called online estimates. The model is compared with the same GRU without sensor inputs, with the same GRU trained on assumed (reconstructed) wear labels, and with extrapolating the last measured wear rate, called the rate carried forward. Two public datasets provide supporting tests: PHM-AP 2025, with genuinely sparse inspections, and the 2010 PHM Society data challenge dataset (PHM 2010) [22], with a single milling condition. Table 1 compares the training targets and outputs of the closest published approaches.
Two research questions were posed.
- Research question 1: Can wear changes measured between inspections, without assumed intermediate wear values, train a model whose per-cut estimates agree with wear measured at every cut, and how does it compare with the same model trained on assumed values?
- Research question 2: When do machining sensor signals improve wear estimation beyond the inspection history alone, for unseen cutting conditions and new tools, during machining and after the next inspection?
The main contributions of this study are summarized as follows:
- A measured-interval learning formulation for flank wear, in which a sequence model predicts non-negative per-cut wear increments and is trained only on wear measured at inspections, so no assumed intermediate wear values are needed (Section 2.1);
- A direct check of such per-cut estimates against wear measured after every cut, showing what the model recovers (cumulative wear and the wear-rate trend of each run) and what it does not (cut-to-cut variation) (Section 2.2, Section 2.3 and Section 2.4 and Section 3.1, Section 3.2, Section 3.3 and Section 3.4);
- Evidence on when machining signals are worth using: mainly for a new tool before its own wear rate has been measured, not once that rate is known and not after the next inspection, from comparisons with the same model without sensors, with assumed-label training and with simple rules based on the inspections alone, on three datasets (Section 3 and Section 4).
Section 2 states the formulation and then describes the datasets, inspection simulations and evaluation protocols. Section 3 reports the hard-turning results, the comparison with reconstructed labels and the supporting public-dataset results. Section 4 discusses the findings against the research questions and states the limitations.
2. Materials and Methods
Section 2.1 states the learning formulation used in all experiments, and Figure 1 summarizes the complete method: data structure, model, training target, estimation and evaluation. The hard-turning dataset, in which wear was measured after every cut, answers research question 1 by direct scoring against the withheld measurements (Section 2.2, Section 2.3 and Section 2.4). The sensor ablations, the analysis of the first inspection interval of a new tool and the two public datasets address research question 2 (Section 2.4, Section 2.5, Section 2.6 and Section 2.7); PHM-AP 2025 has genuinely sparse inspections, and PHM 2010 adds a single-condition milling dataset. Preprocessing and model settings were fitted separately for each dataset, so the experiments assess the training formulation rather than the transfer of one trained network between machining processes. The hard-turning settings and seeds are listed in Table S1.
2.1. Measured-Interval Learning Formulation
The formulation can be followed through one example (Figure 1b). If physical wear were 40 µm after Cut 1 and 65 µm after Cut 6, the only training target for that interval would be the 25 µm increase. Wear after Cuts 2–5 would remain unmeasured. The model outputs five non-negative increments for Cuts 2–6, and the loss compares their sum with 25 µm, so only measured wear enters the loss.
Let Wt,a be the measured cumulative wear of tool or run t at inspection cut a. For PHM-AP, the inspection set is A = 1,6,11,16,21,26; for the hard-turning dataset, it is the simulated schedule. For PHM-AP Cuts 2 − 26 and for Cuts 2 to the last cut of each hard-turning run, the sequence model produces unconstrained scores ut,i.
The input features of each cut are processed in sequence by the two-layer GRU. The final GRU hidden state is mapped by a trainable linear output layer to the scalar . A softplus function maps it to a strictly positive cut-level wear increment, which enforces the non-negative increment assumption and remains differentiable for gradient-based training:
During training, cumulative wear is accumulated from the first physical measurement:
For adjacent inspection cuts ak and bk, the individual increments are unknown, but their sum is observed as . Two forms of the training loss use this information. For PHM-AP, each measured interval contributes one residual. With ωt,k the sensor-coverage weight (Section 2.6) of interval k of tool t, the interval loss is the weighted Huber loss [23] over the five measured intervals:
Here, H1(z) = z2/2 for |z| ≤ 1 and H1(z) = |z| − 1/2 otherwise.
For the hard-turning dataset, the residual is taken on cumulative wear at each inspected cut after the first. Accumulation starts from the first measurement (Equation (2)) and does not restart at intermediate inspections; residuals are averaged within each run and then over the N training runs:
where Kt is the number of inspections of run t after the first and bk is the cut of the kth of them. Both forms use only wear measured at inspected cuts but weight errors differently: in the cumulative form, an error in an early interval also enters the residuals at later inspections. The interval form allows each interval to be weighted by its sensor coverage, which the PHM-AP data require because some cuts have incomplete sensor records; the hard-turning runs have complete signals, and the cumulative form directly penalizes errors in the cumulative wear that is later scored. In both datasets, a soft profile penalty also guides the shape of the predicted increments during training (Section 2.4 and Section 2.7).
Online estimation. The features of a cut are complete when the cut ends, so the online estimate for cut i is made at the end of that cut. It uses signals up to cut i and the wear measured at the last inspection a(i) ≤ i (Figure 1c):
The estimate restarts from each new physical measurement and never uses the next inspection, whereas training accumulates from the first measurement (Equation (2)). For the PHM-AP evaluation trajectories, only the Cut 1 measurement was available, so Equation (5) reduces to accumulation from Cut 1.
Estimation after the next inspection. After the next inspection b, the predicted increments in the interval that starts at inspection a are rescaled so that they add up to the measured change (Figure 1c):
If the predicted increments of an interval sum to zero, the measured change is split equally. In the simulated hard-turning and PHM 2010 schedules, the last cut of each run was treated as an inspection, so every run ends with a complete interval. Measurements withheld by a schedule are used only for scoring.
2.2. Hard-Turning Dataset and Cutting Conditions
The principal evaluation uses a hard-turning dataset collected at the Advanced Remanufacturing and Technology Centre (ARTC), Singapore, and described in [24,25]; it is referred to below as the hard-turning dataset. Hardened 100Cr6 steel cylinders were wet-turned with ceramic inserts on a HAAS ST-10 under eight combinations of cutting speed (100 or 140 m/min), feed (0.1 or 0.2 mm/rev), and depth of cut (0.1 or 0.2 mm) (Table 2). Four runs were planned for each condition, recorded as four repeat series that each covered all eight conditions; according to the recording timestamps of the signal files, the series were run in four successive campaigns between July and September 2018, the last about four weeks after the third. Force, tool vibration, spindle vibration, and acoustic-emission (AE) signals were sampled at 25,600 Hz. Flank wear was measured after every cut with a ZEISS Smartzoom 5 digital microscope at 200× magnification [26]. Of the 32 runs, 28 had complete signal-wear pairing and were retained; four were excluded because one or more sensor files were missing or flagged as unusable in the data records. The retained runs contain 12–46 cuts (median 23.5), with 691 cuts in total (Figure 2).
Because wear was recorded after every cut, sparse inspection schedules were simulated by giving each method only the scheduled measurements and scoring the withheld ones. The 663 measured wear increments had a median of 4.0 µm (10th–90th percentile, 3–8 µm); none was zero or negative. Repeated readings were not taken, so the measurement noise was estimated from the wear curves themselves: the variation that remains after the local trend of each curve is removed (second differences) gives a standard deviation of about 0.62 µm for one measured increment, or 0.86 µm with a robust estimator (Table S2). By this estimate, 99.5% of the measured increments exceed twice the noise level.
2.3. Test Scenarios and Leakage Control
The evaluation varies three factors (Figure 1d). The first is the split. For an unseen cutting condition, all runs of one of the eight conditions are held out and the model is trained on the other seven (leave-one-condition-out); for seen conditions, one repeat series is held out and the other three stay in training (leave-one-repeat-out). The second is the inspection interval: every 5 or every 10 cuts. The third is when the estimate is made. The online estimate for a cut uses only information up to that cut and starts from the last measured wear value (Equation (5)); the estimate after the next inspection knows both ends of the interval and fills the gap between them (Equation (6)), the setting in which interpolation is also possible.
The primary scenario is an unseen cutting condition with inspection every 5 cuts, because a cutting condition absent from training is the situation the method is intended for; all other scenarios are also reported. The fixed 2,000-epoch configuration, with five seeds (17, 42, 91, 123 and 2024), was used to provide a consistent comparison across methods. This setting was selected following initial exploratory experiments rather than through an independent validation protocol. Results obtained using training-only validation for epoch selection are reported separately in Section 3.2 to make the sensitivity to this choice transparent. Withheld per-cut wear was not used for model fitting or for choosing settings. For each held-out condition or repeat series, feature selection, imputation, standardization, and the progress scale were fitted on training runs only. Metrics were averaged over the five seeds within each run and then over runs. Paired differences between methods are means over runs; their 95% intervals are percentile intervals from 5,000 bootstrap resamples of the eight cutting conditions, applied to condition-level mean differences. The intervals are computed separately for each comparison.
2.4. Hard-Turning Features, Model and Baselines
Signal features. Each signal was cut into 1.0 s windows (at most 24 windows per cut). Cuts were found from the signal envelope on 0.25 s blocks (median absolute deviation threshold of 6, gaps shorter than 0.5 s merged, 0.5 s padding). For each window, time-domain statistics and Welch power-spectrum features [27] were computed (segments of up to 2,048 samples with 1,024 overlap, constant detrending), and the window values were summarized per cut. The model used 32 of these summaries: for each of the ten channels (three force axes, three tool-vibration axes, three spindle-vibration axes and AE), the per-cut means of the window root mean square, peak-to-peak amplitude and total spectral power, together with the active cut duration and the material removed in the cut. All 32 features were non-constant and were kept in every training split. A cumulative material-removal index, scaled by the median training total and clipped to 0 to 1, served as the progress input; it uses only the cut times and the cutting conditions, so it is available online.
Model and training. The GRU has two layers with 32 hidden units, dropout 0.1, and a softplus output that keeps predicted wear increments non-negative. Training used the cumulative form of the loss (Equation (4)) with a Huber threshold of 1 µm. A second term, weighted by 0.25 in the main comparison, compares the normalized shape of the predicted increments within a run with a U-shaped reference profile, exp(3(x − 0.5)2), where x runs from 0 to 1 over the run; at 1,000 epochs, setting this weight to 0 changed the cumulative-wear RMSE by less than 0.1 µm. Training used AdamW (learning rate 10−3, weight decay 10−4), gradient clipping at 5, full-batch updates, and 2,000 epochs; Table S1 lists all settings. In the sensor ablation, the progress-only model keeps only the progress input and sets the other 32 features to zero; removing a sensor group sets only that group’s features to zero, and using a group alone keeps that group and the progress input.
Reconstructed-label baselines. Four rules build a wear increment for every cut between inspections from the visible measurements only (Section S3): equal split (linear interpolation); a monotone piecewise cubic Hermite interpolating polynomial (PCHIP); a natural cubic spline; and the interval total split by the same U-shaped profile. Each rule takes the differences of its curve, sets negative values to zero, and rescales the changes inside each interval so that they are non-negative and add up exactly to the measured interval change (equally split if all values are zero). The same GRU, inputs and 2,000 epochs are then trained on these labels with a per-cut loss. Other baselines use the same inputs and training length: a linear additive model and a per-cut multilayer perceptron (MLP), both trained with measured-interval supervision; the last measured wear rate carried forward, called the rate carried forward below (no sensors; the mean rate of the training runs is used before the first interval of a run is complete); and, after the next inspection, linear or PCHIP interpolation between inspections. The rate carried forward and interpolation use the measured wear only and are called inspection-only baselines. Two classical temporal-disaggregation methods were also applied after the next inspection: Denton first-difference disaggregation [21] with the material removed per cut as indicator, and Chow–Lin regression disaggregation [20] with the highest-ranked sensor features as indicators, fitted on the training runs and constrained to non-negative increments.
2.5. PHM-AP 2025 and PHM 2010: Datasets and Measurement Design
PHM-AP 2025 was the initial development dataset and provides genuine sparse inspections. The experiments used stainless-steel cylindrical workpieces in a face-cutting operation on a DMG Mori NTX2500 mill-turn machine at a 0.5 mm depth of cut [2,9]. A triaxial accelerometer and an acoustic-emission sensor were mounted on the tool holder (Figure 3a); both signal sources were sampled at 25,600 Hz. Twenty-three CNC operating channels recorded machining state, commanded feed, spindle speeds and loads, axis loads, and coolant status [2,9]. Each of the six training tools contains 26 cuts but only six physical cumulative flank-wear measurements, after Cuts 1, 6, 11, 16, 21, and 26 (Figure 3c). These measured wear values are called anchors below. Three further tools, the evaluation trajectories, contain 26, 25 and 26 retained cut records. When the three evaluation trajectories were predicted, only their measured Cut 1 wear was available, as the starting value.
PHM 2010 [22] provides three milling cutters (c1, c4 and c6) under one cutting condition, with flank wear measured after every cut; the wear value of a cut is the maximum over the three flutes. It is used as a second single-condition check with the same scenarios (inspection every 5 or 10 cuts, online estimation, leave-one-cutter-out) and the same feature types and settings as the hard-turning GRU, extracted from its force, vibration and AE channels. Table 3 summarizes the measurement structure and role of each dataset.
2.6. PHM-AP Features
All PHM-AP processing was done inside each outer fold, one of the six leave-one-tool-out splits: one complete training tool is held out, and the other five (outer-training) tools are used for all preprocessing and fitting. Sensor files, which span groups of cuts, were aligned with the per-cut CNC operating files by timestamps. A 5.0 s margin was removed from each active cut, and the remainder was divided into 1.0 s windows with 50% overlap; the weight of an interval in Equation (3) is the mean, over its five cuts, of the fraction of each cut for which sensor data were recorded. CNC operating descriptors (active cutting time, feed rate, spindle speeds and loads, axis loads and coolant duty cycle) were added to the sensor features. An operating-load index, the cumulative sum over active controller rows of active duration, spindle-load fraction and spindle speed multiplied together, served as an optional progress input, called exposure below. The descriptors and the index definition (Equation (S1)) are given in Section S4.
Each sensor window was summarized in the time, frequency, and time-frequency domains using standard statistical descriptors, power-spectrum features from a Hann-windowed fast Fourier transform (FFT) [28], and short-time Fourier transform (STFT) and continuous wavelet transform (CWT) descriptors [29,30]. Values from all retained 1.0 s windows belonging to the same cut were aggregated by mean, standard deviation, and linear trend. The resulting dictionary contained 637 fields, of which 634 were numeric and 598 were not constant. The broad catalog was intentionally redundant: 1,158 feature pairs had absolute correlation of at least 0.95. Within each outer fold, feature filtering, median imputation, standardization, and representation learning used outer-training data only. The 64 features with the highest training variance were then compressed by a masked autoencoder into a 32-dimensional embedding, which was the model input; the descriptor and autoencoder settings are given in Section S4.
2.7. PHM-AP Model, Comparators and Evaluation
The PHM-AP estimator is a two-layer GRU [31] with 64 hidden units, dropout 0.1 and a softplus output (43,841 trainable parameters), applied to the 32-dimensional masked-autoencoder embedding [32]. It was trained with the interval loss of Equation (3), a soft wear-profile penalty and a penalty on differences between adjacent increments, using AdamW with a learning rate of 10−3, weight decay of 10−4, gradient-norm clipping at 5, at most 180 epochs and an early-stopping patience of 30 epochs [33,34]. The profile, either a normalized cumulative logistic curve or a constrained three-stage wear-rate profile fitted to the anchors of the training tools, acts as a soft prior on the shape of the increments. The profile equations (Equations (S2)–(S8)), loss weights and the fold-isolated training procedure (Algorithm S1) are given in Section S5.
Internal comparison methods were grouped by their training target. Measured-interval neural models comprised the GRU, a convolutional neural network–long short-term memory (CNN-LSTM) model, and a Transformer [31,32,35,36,37]. These models predicted non-negative per-cut wear increments. Reconstruction-first histogram gradient boosting (HGB) and XGBoost models were trained on fold-specific non-negative per-cut targets reconstructed from training anchors [38,39]. Direct cumulative-wear baselines used only physical wear anchors. A control using the same GRU architecture changed only the target from measured interval changes to reconstructed per-cut targets, isolating target formulation from architecture and inputs.
Two published PHM-AP approaches were implemented as adapted comparators. The Mielgo-style comparator aggregated interval features, selected 14 features by correlation within the training tools, and trained a three-hidden-layer multilayer perceptron [9]. It is described as adapted because several raw interval formulas and one excluded training set cannot be reconstructed exactly from the available cut summaries. The Kunte–Manakari comparator formed all labeled anchor pairs, summed features from the cut after the first anchor through the second anchor, and trained a 1000-tree random forest with maximum depth 5 to predict the wear difference [10]. Wang’s Usui–random-forest method was not reproduced because the report does not provide the constants required to generate its reconstructed wear labels [6].
Reconstructed labels for the PHM-AP comparators. For the HGB, XGBoost and reconstructed-label GRU comparators, the per-cut labels were rebuilt from the training anchors with the rule that gave the lowest reconstruction RMSE at withheld anchors of the outer-training tools in a leave-one-tool-out reconstruction test; the held-out tool was never used. The chosen rule was then rescaled so that the per-cut labels were non-negative and added up to each measured interval change, as in Section 2.4.
The comparisons cover three groups: internal controlled baselines, adapted published methods, and methods that could not be reproduced from the published information and are discussed in Section 4.
Two analyses were run on the six leave-one-tool-out folds. In both, one of the five outer-training tools, the inner tool, was held back to choose settings such as the number of epochs. In the development analysis (Table S3; Section S6), a prespecified configuration (CNC inputs, logistic profile with weight 0.25, adjacent-increment weight 0.05) was trained, with the epoch chosen on the inner tool; its exposure was normalized with each tool’s complete run, so this analysis uses information that is not available online. In the model-selection analysis, the architecture (GRU or convolutional recurrent), profile family, profile weight (0 to 2) and epoch were chosen on the inner tool, the exposure scale came from the training tools only, and the profile was fitted without the inner tool. The primary metric was RMSE at Cuts 6, 11, 16, 21 and 26, with each estimate starting from the measured Cut 1 wear; seeds 17, 42 and 91 were averaged within each held-out tool before the six-tool summaries were calculated. The three evaluation trajectories were predicted after the configurations had been fixed, using only their Cut 1 measurement. Wear errors are reported to one decimal place.
3. Results
Section 3.1, Section 3.2 and Section 3.4 address research question 1: the accuracy of training on measured wear changes alone, its agreement with the wear measured at every cut, and its comparison with training on assumed wear labels. Section 3.3 and Section 3.5 address research question 2, where the sensor signals add information, and Section 3.6 and Section 3.7 report the PHM-AP comparison with published methods.
3.1. Online Estimation Under Unseen Cutting Conditions
Table 4 gives the main comparison. When a whole cutting condition was held out and inspection took place every 5 cuts, the GRU had a mean online RMSE of 4.4 µm on the withheld wear, and 7.7 µm with inspection every 10 cuts. Each run was stopped at 0.15 mm of flank wear (Table 2), so 4.4 µm is about 3% of the wear at the end of a run. Without the sensor inputs, the error rose to 6.1 µm, and the linear additive model reached 8.3 µm. The per-cut MLP, which uses the same sensor inputs, gave 5.1 µm, and the rate carried forward gave 5.3 µm every 5 cuts and 11.1 µm every 10 cuts; these differences from the GRU were not statistically significant. The GRU trained on reconstructed wear labels gave 4.6 to 4.8 µm; this comparison is treated in Section 3.4. Figure 4a shows these results, and Figure 5 shows the held-out run with the median error.
Section 3.3 shows where in a run the difference from the rate carried forward arises.
3.2. Per-Cut Check Against Measured Wear
Wear was recorded after every cut, so predicted increments could be scored directly on all 28 runs. Increment metrics were computed on the withheld cuts within each run and then averaged over runs, so differences in average wear rate between runs do not contribute to the correlation. In the main comparison (2,000 epochs; unseen conditions, online, inspection every 5 cuts), the mean within-run correlation between predicted and measured increments was 0.56, with an increment RMSE of 1.85 µm (Table S4 and Table S5). This correlation mainly reflects the trend of the wear rate over each run. After a linear trend was removed from both measured and predicted increments within each run, it fell to 0.08, and the remaining variation of the measured increments (median standard deviation 0.96 µm) was close to the measurement-noise proxy of 0.62 µm (Section 2.2; Table S6). The estimates therefore capture how the wear rate rises or falls during a run, rather than the cut-to-cut variation around this trend, which is of the same order as the measurement noise. The GRU without sensors had a lower correlation (0.26), but most of this gap came from variation between training seeds: when the five seed predictions were averaged before scoring, the correlations were 0.50 without and 0.58 with sensors. The sensors therefore improve mainly the cumulative wear estimate, not how closely the increments follow the measured ones. After the next inspection, the correlation was 0.72 and the RMSE 0.95 µm per cut, because the later measurement fixes the interval total.
Training length affected these results (unseen conditions, five-cut inspections). With a fixed training length of 1,000, 2,000 or 4,000 epochs, the cumulative-wear RMSE was 4.4–4.5 µm and the increment correlation 0.54–0.56, so the results are stable above 1,000 epochs. Shorter training was worse. In a first experiment, the training length (100, 300 or 1,000 epochs) and the profile weight (0 or 0.25) were chosen by validation on the inspected wear of the training runs. This validation chose 100 or 300 epochs in 17 of the 40 fold–seed cases, and the chosen models had an RMSE of 5.6 µm, an increment correlation of 0.22 and an increment RMSE of 2.22 µm. Validation on inspected wear therefore did not reliably choose a long enough training run. Table S7 lists the results for the fixed training lengths of 1,000, 2,000 and 4,000 epochs.
3.3. What the Sensors Add, and Where
Table 5 and Figure 4b remove each sensor group in turn and also use each group alone. With inspection every 5 cuts, removing spindle vibration raised the RMSE by 0.9 [0.1, 2.5] µm and removing force by 0.3 [−0.1, 0.6] µm (difference and 95% interval); removing AE or tool vibration changed it by less than 0.1 µm. Each group alone was worse than all groups together. Force was the best group on its own, and spindle vibration was the group whose removal raised the error most; AE and tool vibration added nothing measurable on top of the others.
A post hoc analysis then located where in a run the sensors help. The first interval of a new tool has no measured wear rate of its own, so the rate carried forward is the mean rate of the training runs. In that interval, the GRU had an RMSE of 6.0 µm every 5 cuts, against 9.6 µm for the rate carried forward; in later intervals the rate carried forward was better (3.4 against 3.9 µm; Table 6). In the first interval, the predicted wear rate correlated with the measured one at 0.65 (95% interval 0.27 to 0.87) every 5 cuts and at 0.56 every 10 cuts (Table S8); the GRU without sensors gave −0.24 every 5 cuts.
The sensors therefore helped most where no measured rate of the tool was yet available. In later intervals, the tool’s own measured rate was as good or better on average. On seen conditions (a whole repeat series held out), the GRU did not improve on the GRU without sensors or on the rate carried forward, and its error was higher than on unseen conditions (Table 7). A post hoc check traced this to differences in sensor level between the four repeat series. At the same cutting condition, the acoustic-emission level of Repeat 4 was 1.7 standard deviations above that of the other repeats, and the spindle vibration of Repeat 1 was 0.75 standard deviations higher (first three cuts of each run, after removing the mean of each condition). When a whole repeat was held out, the model therefore met sensor levels it had not seen in training: with inspection every 5 cuts, its RMSE was 10.8 µm on Repeat 4 and 6.9 µm on Repeat 1, against 3.6 and 3.5 µm for the same runs when their repeat series was part of the training data. The GRU without sensors was not affected (5.3 against 5.5 µm on Repeat 4). Figure 6b shows how the pattern varies between conditions.
3.4. Measured-Interval Supervision Against Reconstructed Wear Labels
Table 7 shows that, with the same GRU, inputs and training length, measured-interval training and the four reconstructed-label rules had similar cumulative-wear errors on unseen conditions with inspection every 5 cuts. This is the bag-level against instance-level comparison of aggregate learning [19]; neither target was consistently more accurate. On seen conditions with inspection every 10 cuts, equal-split, PCHIP and spline labels had lower online RMSE by 0.8–1.0 µm (intervals excluding zero; Table S9). After the next inspection, methods that use only the two measured ends were the most accurate: PCHIP interpolation and Denton disaggregation both gave 0.9 µm every 5 cuts, Chow–Lin disaggregation gave 1.1 µm, and the rescaled GRU estimate gave 1.2 µm. Measured-interval supervision therefore reaches the accuracy of reconstructed-label training without assuming intermediate values; once both ends of an interval are known, interpolation is the most accurate choice.
3.5. Single-Condition Checks: PHM-AP 2025 and PHM 2010
Table 8 summarizes the online checks on the two single-condition datasets. For PHM-AP, this check uses the hard-turning GRU settings (2,000 epochs, five seeds) with fixed per-cut sensor and CNC features and no masked autoencoder, so its errors differ from those of the PHM-AP estimator in Section 3.6. In both, the inspection-only baselines were at least as accurate as the GRU. On PHM-AP, the GRU had a higher error than the GRU without sensors and the rate carried forward under both schedules. On PHM 2010, with inspection every 5 cuts, the GRU had an RMSE of 1.7 µm, against 1.3 µm without sensors and 0.8 µm for the rate carried forward; with inspection every 10 cuts, the values were 3.4, 2.6 and 2.1 µm. This agrees with the hard-turning result in Section 3.3: when all tools share one cutting condition, the mean wear rate of the training tools is already a good estimate for a new tool, so the signals have little to add. After the next inspection, PCHIP interpolation was again more accurate than the rescaled GRU estimate (0.1 against 0.2 µm on PHM 2010 every 5 cuts).
3.6. PHM-AP 2025 Method Comparison at the Released Measurements
Table 9 and Figure 7 compare nine methods at Cuts 6, 11, 16, 21, and 26, with seeds averaged within each held-out tool before the six-tool summaries were calculated. The model-selection analysis, which uses information from the training tools only, gave a mean RMSE of 12.2 µm (worst tool 20.4 µm). The adapted Kunte–Manakari pairwise random forest had 11.8 µm (worst tool 17.3 µm). The GRU of the development analysis also had 11.8 µm, but its exposure was normalized with each tool’s complete run, which is not possible online. The ranking depended on the held-out tool: in the development analysis, the GRU had lower RMSE than the random forest on three tools, the random forest on two, and the sixth was tied (Table S10). The PHM-AP results therefore show accuracy at the measured inspections similar to that of the strongest adapted published method.
Ridge regression and a direct cumulative multilayer perceptron, fitted to the six measured wear values per tool, did not give usable estimates under the same folds (Section S10). The Transformer also showed greater variation across seeds and tools than the recurrent models. The recurrent increment model was retained as the neural implementation used to evaluate measured-interval supervision.
3.7. PHM-AP Component Tests and Diagnostics
In the development analysis, adding the CNC inputs, the logistic profile or both changed the mean RMSE by at most 0.1 µm (11.9 µm without either, 11.8 µm with both). In the model-selection analysis, each of the following also changed the mean RMSE by less than 0.1 µm: removing the profile; removing the CNC inputs and exposure; replacing exposure with the fraction of the run completed; and shuffling exposure randomly between cuts. Training on reconstructed per-cut targets instead lowered it by about 0.4 µm. With the same GRU, measured-interval and reconstructed per-cut targets gave 11.9 and 12.5 µm without CNC inputs or profile, and 11.8 and 11.7 µm with both. These components therefore add no measurable accuracy. The 14 wear values released later for the three evaluation trajectories were predicted before they were loaded. Over these 14 values, the development model had an RMSE of 18.4 µm, reconstructed-target XGBoost 25.0 µm, and the model-selection configuration 17.1 µm (mean of three seeds). These are checks after the configurations were fixed, not official challenge scores. Other choices of the inner tools agreed on the full configuration in 49% of cases and changed the mean RMSE by about 0.5 µm. Applying the sensor-data loss of the third evaluation trajectory to complete data changed the mean RMSE by about 0.1 µm (95% interval −0.4 to 0.6 µm). Table S11–S14 and Section S10 give the component, released-value and sensitivity results.
4. Discussion
4.1. Answers to the Research Questions and Comparison with Published Methods
The main result is that wear changes measured between inspections are sufficient to train an estimator of the wear added by each cut. For research question 1, the GRU trained only on these changes estimated online cumulative wear with an RMSE of 4.4 µm for unseen cutting conditions with five-cut inspections, about 3% of the wear at the end of a run, and followed the wear-rate trend within each run (mean within-run correlation 0.56). With the same GRU, inputs and training length, training on reconstructed labels gave 4.6–4.8 µm (Section 3.4). The measured-interval formulation therefore reaches the same accuracy while using only measured wear, which removes the need to choose an interpolation rule for the unmeasured cuts. The direct per-cut comparison also shows the resolution of the estimates: after the linear trend of each run was removed, the increment correlation fell to 0.08, and the remaining variation of the measured increments was close to the measurement-noise proxy. The estimates therefore describe the wear-rate trend, and resolving finer cut-to-cut changes would require repeated or more precise wear readings.
For research question 2, the sensor signals mattered most where the inspection history carries no information about the tool. In the first interval of a new tool under an unseen condition, the GRU had an RMSE of 6.0 µm against 9.6 µm for the rate carried forward (every 5 cuts; post hoc analysis, Section 3.3), and its predicted wear rate correlated with the measured one (0.65), whereas the GRU without sensors did not (−0.24). Once the tool’s own rate had been measured, carrying it forward was as accurate or more accurate. The two public datasets agree with this picture: with a single cutting condition, the mean rate of the training tools is already a good estimate for a new tool, and the inspection-only baselines were at least as accurate as the GRU. The held-out repeat series show a second requirement: sensor levels shifted between test campaigns, and the sensor inputs helped only when the campaign of the test run was represented in training (Section 3.3). After the next inspection, interpolation and Denton disaggregation were the most accurate, because both measured ends of the interval are then available.
On PHM-AP, with genuinely sparse inspections, measured-interval training reached the accuracy of the strongest adapted published method at the measured inspections: 12.2 µm for the model-selection analysis, which uses the training tools only, and 11.8 µm for the development analysis, against 11.8 µm for the adapted Kunte–Manakari random forest, with a ranking that changed with the held-out tool. The CNC operating signals and the wear-profile terms changed the mean error by about 0.1 µm or less, so this result rests on the measured-interval formulation itself rather than on these components. Mielgo et al. showed that engineered interval features and a compact multilayer perceptron can perform well in the PHM-AP challenge setting [9]; the adapted implementation performed poorly under the present six-fold protocol, whose preprocessing differs from the published one. Wang’s approach adds mechanical content through an Usui-type label-generation model [6], and physics-informed models combine force and wear equations with learning [13]; both need calibration constants, forces, geometry or temperatures that PHM-AP does not supply. Nguyen et al. generate physics-guided pseudo-samples for Gaussian-process updates [3]; the present method instead keeps the intermediate increments latent and constrains only their measured interval totals, which makes it applicable wherever periodic wear measurements and per-cut signals are recorded.
The hard-turning results suggest that sensor-based estimation is particularly useful when the wear rate of a new tool is not yet established. Once sufficient inspection history becomes available, simpler inspection-based methods may provide comparable or better accuracy at lower implementation complexity. Therefore, the proposed method is best viewed as a complementary approach for estimating wear between inspections rather than a replacement for physical inspection or the rate carried forward.
4.2. Limitations
The hard-turning data come from one machine, one insert and workpiece material, and eight cutting conditions. Sensor levels also differed between repeat series at the same condition (Section 3.3), so a model applied to a new set-up or measurement series may need data from that series before its sensor inputs help. The unseen cutting conditions considered in this study represent withheld combinations of cutting parameters within the investigated operating range, rather than extrapolation beyond that range. The primary scenario, the first-interval analysis and the 2,000-epoch setting were fixed after initial results were known. Furthermore, measurement uncertainty was estimated indirectly from variations in the recorded wear curves, without repeated physical measurements. The increment correlation was 0.56 with fixed 2,000-epoch training but 0.22 when the training length was chosen by validation on inspected wear, so the results are sensitive to this setting. Training accumulates wear from the first measurement, whereas online estimation restarts at each inspection. The two rules share the same ideal solution, because the cumulative residual at an inspection is the sum of the interval residuals up to that inspection; they differ only in how remaining errors are weighted, and this weighting difference was not compared empirically. Finally, interval supervision constrains agreement at measured inspections but does not identify a unique physical wear increment for every cut. These estimates should not be used alone to decide when to replace a tool. The findings on cut-to-cut variation and on other machining conditions therefore require further validation.
A further study should test whether predicted increments follow independent process evidence, for example by combining in-process prediction with explainable analysis and physics-based checks of machining behavior. Such a study would also confirm the first-interval rate association, which was found post hoc.
PHM-AP contains six independent training tools from one machine and operation. Leave-one-tool-out evaluation is appropriate for this sample but does not remove the large finite-sample uncertainty or configuration sensitivity shown by the other choices of inner tools (Section 3.7). In the development analysis, the profile was fitted on anchors that included the inner tool. The three later evaluation trajectories give a check after the configurations were fixed, but only 14 of their wear values are released and one trajectory has repeated sensor-data loss.
For PHM-AP, the organizer documentation available to this study does not state the wear-inspection instrument, image-reduction rule, repeatability, or measurement uncertainty. Its wear-error metrics are therefore rounded to one decimal place. In the development analysis, exposure was normalized with each tool’s complete run, which is not possible online.
5. Conclusions
Wear changes measured between periodic inspections are sufficient to train a GRU that estimates the wear added by each cut, without assumed intermediate wear values. Tested against withheld per-cut wear in 28 hard-turning runs, its online estimates for cutting conditions excluded from training, with inspection every five cuts, had a cumulative-wear RMSE of 4.4 µm, about 3% of the wear at the end of a run, and followed the wear-rate trend within each run, while the cut-to-cut variation around this trend was of the same order as the measurement noise. Training the same GRU on assumed intermediate values gave similar accuracy, so measured-interval supervision reaches this accuracy using measured wear only.
Sensor signals reduced the error relative to the same model without sensors, mainly in the first inspection interval of a new tool under a new cutting condition (post hoc analysis), where no measured rate of that tool exists. Once the tool’s own rate is measured, extrapolating it is as accurate, and after the next inspection, interpolation is the most accurate estimate. In two public datasets with a single cutting condition, the mean rate of the training tools was already a good estimate and the sensors added no benefit. On PHM-AP 2025, accuracy at the measured inspections was similar to that of the strongest adapted published method.
The approach is therefore suited to estimating wear between inspections for a new tool under a new cutting condition, with physical inspection retained as the reference. Confirmation on independently collected runs, with repeated wear readings to quantify measurement uncertainty, is the next step.
Supplementary Materials
The following supporting information can be downloaded at the website of this paper posted on Preprints.org. Table S1: Settings used for the hard-turning results; Table S2: Measurement-noise proxy from the hard-turning wear curves; Table S3: Controlled configurations in the PHM-AP development analysis; Table S4: Cut-to-cut wear-change metrics, inspection every 5 cuts; Table S5: Cut-to-cut wear-change metrics, inspection every 10 cuts; Table S6: Increment correlation with and without the within-run trend; Table S7: Training-length check; Table S8: First interval of a new tool; Table S9: RMSE on withheld cuts, inspection every 10 cuts; Table S10: Per-tool RMSE of the development GRU and the adapted pairwise random forest; Table S11: Component results in the PHM-AP development analysis; Table S12: Target-formulation comparison in the PHM-AP development analysis; Table S13: Matched component substitutions in the PHM-AP model-selection analysis; Table S14: Errors at the released PHM-AP wear values; Algorithm S1: Training within each fold and estimation for the held-out tool.
Author Contributions
Conceptualization, J.W., K.P.Y. and M.Y.H.L.; methodology, J.W. and P.X.; software, J.W.; validation, J.W., K.P.Y., M.Y.H.L., P.X., N.C.N.D. and C.X.; formal analysis, J.W.; investigation, J.W.; resources, C.X. and N.C.N.D.; data curation, J.W.; writing—original draft preparation, J.W.; writing—review and editing, all authors; visualization, J.W.; supervision, K.P.Y., M.Y.H.L., N.C.N.D. and C.X. All authors have read and agreed to the revised version of the manuscript.
Funding
This research was supported by the Ministry of Trade and Industry (MTI) and A*STAR under the Sectoral Artificial Intelligence Centre of Excellence for Manufacturing Programme (award No. W24MFMF001).
Data Availability Statement
The PHM-AP 2025 and PHM 2010 datasets are publicly available from the challenge websites. The hard-turning dataset and its measurement protocol were described in [24,25]. Restrictions apply to the availability of its per-cut features and wear measurements, which were used with the permission of ARTC; these data are available from the authors with the permission of ARTC. The analysis code, the run and condition assignments and the inspection schedules are available from the corresponding author on reasonable request.
Acknowledgments
The authors thank the PHM-AP 2025 Data Challenge organizers for releasing the machining dataset and technical reports. The authors acknowledge the Advanced Remanufacturing and Technology Centre (ARTC), A*STAR, for access to the institutional hard-turning data.
Conflicts of Interest
The authors declare no conflicts of interest.
Abbreviations
| Abbreviation | Definition | Abbreviation | Definition |
| AE | Acoustic emission | HGB | Histogram gradient boosting |
| ARTC | Advanced Remanufacturing and Technology Centre | MLP | Multilayer perceptron |
| CI | Confidence interval | PCHIP | Piecewise cubic Hermite interpolating polynomial |
| CNC | Computer numerical control | PHM | Prognostics and Health Management |
| CNN-LSTM | Convolutional neural network–long short-term memory | PHM-AP | Prognostics and Health Management Asia-Pacific |
| CWT | Continuous wavelet transform | RMSE | Root mean square error |
| FFT | Fast Fourier transform | STFT | Short-time Fourier transform |
| GRU | Gated recurrent unit | XGBoost | eXtreme Gradient Boosting |
References
- Colantonio, L.; Equeter, L.; Dehombreux, P.; Ducobu, F. A Systematic Literature Review of Cutting Tool Wear Monitoring in Turning by Using Artificial Intelligence Techniques. Machines 2021, 9, 351. [Google Scholar] [CrossRef]
- PHM Asia Pacific 2025 Data Challenge. Available online: https://phmap25.org/datachallenge.html (accessed on 17 July 2026).
- Nguyen, H.-P.; Nguyen, D.-T.; Kim, J.-M. Gaussian Process Regression with Physics-Guided Pseudo-Sample Augmentation for Wear Prediction under Sparse Measurements in Milling. Sci. Rep. 2026, 16, 7231. [Google Scholar] [CrossRef] [PubMed]
- Yan, J.; Xue, Y.; Zhong, Y.; Bai, L.; Liu, H.; Tang, Y.; Zhang, J. A Data Label Expansion Strategy for Tool Wear Prediction through Data-Driven Approaches. Procedia CIRP 2026, 141, 67–72. [Google Scholar] [CrossRef]
- He, J.; Yuan, L.; Lei, H.; Wang, K.; Weng, Y.; Gao, H. A Novel Piecewise Cubic Hermite Interpolating Polynomial-Enhanced Convolutional Gated Recurrent Method under Multiple Sensor Feature Fusion for Tool Wear Prediction. Sensors 2024, 24, 1129. [Google Scholar] [CrossRef] [PubMed]
- Wang, C. Cutter Flank Wear Prediction Based on Physics-Informed Machine Learning Model for the PHM-AP 2025 Data Challenge. Available online: https://phmap25.org/resources/datachallenge/reports/ENPHM.pdf (accessed on 17 July 2026).
- He, X.; Zhong, M.; He, C.; Wu, J.; Yang, H.; Zhao, Z.; Yang, W.; Jing, C.; Li, Y.; Gao, C. A Novel Tool Wear Identification Method Based on a Semi-Supervised LSTM. Lubricants 2025, 13, 72. [Google Scholar] [CrossRef]
- Li, W.; Fu, H.; Zhuo, Y.; Liu, C.; Jin, H. Semi-Supervised Multi-Source Meta-Domain Generalization Method for Tool Wear State Prediction under Varying Cutting Conditions. J. Manuf. Syst. 2023, 71, 323–341. [Google Scholar] [CrossRef]
- Mielgo, P.; Quinones-Grueiro, M.; Bregon, A.; Coursey, A.; Alonso-González, C.J.; Biswas, G. A Feature-Engineering-Based Machine Learning Approach for Cutter Flank Wear Prediction under Data-Scarce Conditions. Proc. Asia Pac. Conf. PHM Soc. 2025, Vol. 5(No. 1). [Google Scholar] [CrossRef]
- Kunte, D.; Manakari, V. PHM-AP 2025 Data Challenge Technical Report: Team PrognosTech. Available online: https://phmap25.org/resources/datachallenge/reports/PrognosTech.pdf (accessed on 17 July 2026).
- Wang, G.; Zhang, F. A Sequence-to-Sequence Model with Attention and Monotonicity Loss for Tool Wear Monitoring and Prediction. IEEE Trans. Instrum. Meas. 2021, 70, 3525611. [Google Scholar] [CrossRef]
- Zhu, K.; Guo, H.; Li, S.; Lin, X. Physics-Informed Deep Learning for Tool Wear Monitoring. IEEE Trans. Ind. Inform. 2024, 20, 524–533. [Google Scholar] [CrossRef]
- Pashmforoush, F.; Araghizad, A.E.; Budak, E. Physics-Informed Tool Wear Prediction in Turning Process: A Thermo-Mechanical Wear-Included Force Model Integrated with Machine Learning. J. Manuf. Syst. 2024, 77, 266–283. [Google Scholar] [CrossRef]
- Zhang, Y.; Zhu, K.; Duan, X.; Li, S. Tool Wear Estimation and Life Prognostics in Milling: Model Extension and Generalization. Mech. Syst. Signal Process. 2021, 155, 107617. [Google Scholar] [CrossRef]
- Karandikar, J.; Schmitz, T.; Smith, S. Physics-Guided Logistic Classification for Tool Life Modeling and Process Parameter Optimization in Machining. J. Manuf. Syst. 2021, 59, 522–534. [Google Scholar] [CrossRef]
- Zhang, Y.; Charoenphakdee, N.; Wu, Z.; Sugiyama, M. Learning from Aggregate Observations. In Advances in Neural Information Processing Systems; 2020; Volume 33, pp. 7993–8005. [Google Scholar]
- Agarwal, S.; Makhija, Y.; Saket, R.; Raghuveer, A. Aggregating Data for Optimal Learning. In Proceedings of the Forty-First Conference on Uncertainty in Artificial Intelligence;Proceedings of Machine Learning Research; PMLR; Chiappa, S., Magliacane, S., Eds.; 2025; Volume 286, pp. 1–30. [Google Scholar]
- Law, H.C.L.; Sejdinovic, D.; Cameron, E.; Lucas, T.; Flaxman, S.; Battle, K.; Fukumizu, K. Variational Learning on Aggregate Outputs with Gaussian Processes. Adv. Neural Inf. Process. Syst. 2018, 31. [Google Scholar]
- Javanmard, A.; Chen, L.; Mirrokni, V.; Badanidiyuru, A.; Fu, G. Learning from Aggregate Responses: Instance Level versus Bag Level Loss Functions. In Proceedings of the Twelfth International Conference on Learning Representations (ICLR 2024), Vienna, Austria, 7–11 May 2024. [Google Scholar]
- Chow, G.C.; Lin, A. Best Linear Unbiased Interpolation, Distribution, and Extrapolation of Time Series by Related Series. Rev. Econ. Stat. 1971, 53, 372–375. [Google Scholar] [CrossRef]
- Denton, F.T. Adjustment of Monthly or Quarterly Series to Annual Totals: An Approach Based on Quadratic Minimization. J. Am. Stat. Assoc. 1971, 66, 99–102. [Google Scholar] [CrossRef]
- PHM Society. 2010 PHM Society Conference Data Challenge. Available online: https://phmsociety.org/phm_competition/2010-phm-society-conference-data-challenge/ (accessed on 13 October 2026).
- Huber, P.J. Robust Estimation of a Location Parameter. Ann. Math. Stat. 1964, 35, 73–101. [Google Scholar] [CrossRef]
- Du, C.; Bahador, A.; Ng, H.P.; Dzulqarnain, N.A.; Ho, C.L. Tool Wear Size Modeling with Transfer Learning for Hard Turning Processes. In Proceedings of the 12th Conference on Learning Factories (CLF 2022), Singapore, 11–13 April 2022. [Google Scholar] [CrossRef]
- Bahador, A.; Du, C.; Ng, H.P.; Dzulqarnain, N.A.; Ho, C.L. Cost-Effective Classification of Tool Wear with Transfer Learning Based on Tool Vibration for Hard Turning Processes. Measurement 2022, 201, 111701. [Google Scholar] [CrossRef]
- Advanced Remanufacturing and Technology Centre (ARTC). Condition Monitoring for Real-Time Anomalies Detection (Phase 2), Project Code C17_05_ARTC; Confidential Internal Project Report. 2018. [Google Scholar]
- Welch, P.D. The Use of Fast Fourier Transform for the Estimation of Power Spectra: A Method Based on Time Averaging over Short, Modified Periodograms. IEEE Trans. Audio Electroacoust. 1967, 15, 70–73. [Google Scholar] [CrossRef]
- Wan, J.; Yar, K.P.; Du, C.; Low, M.Y.H. Sensor Data Analytics for Tool Condition Anomaly Detection with Machine Learning Techniques. In Proceedings of the 2023 5th International Electronics Communication Conference, Osaka, Japan, 21–23 July 2023; ACM: New York, NY, USA, 2023; pp. 38–45. [Google Scholar] [CrossRef]
- Wan, J.; Yar, K.P.; Low, M.Y.H.; Xu, C.; Doan, N.C.N.; Ng, H.Y.; Wang, W. PI-FSL: Physics-Informed Few-Shot Domain Adaptation for Robust Cross-Domain Condition Monitoring. Technologies 2026, 14, 167. [Google Scholar] [CrossRef]
- Torrence, C.; Compo, G.P. A Practical Guide to Wavelet Analysis. Bull. Am. Meteorol. Soc. 1998, 79, 61–78. [Google Scholar] [CrossRef]
- Cho, K.; van Merriënboer, B.; Gulcehre, C.; Bahdanau, D.; Bougares, F.; Schwenk, H.; Bengio, Y. Learning Phrase Representations Using RNN Encoder–Decoder for Statistical Machine Translation. Proceedings of EMNLP 2014, Doha, Qatar, 25–29 October 2014; pp. 1724–1734. [Google Scholar] [CrossRef]
- Zerveas, G.; Jayaraman, S.; Patel, D.; Bhamidipaty, A.; Eickhoff, C. A Transformer-Based Framework for Multivariate Time Series Representation Learning. In Proceedings of the 27th ACM SIGKDD Conference on Knowledge Discovery and Data Mining, 2021; pp. 2114–2124. [Google Scholar] [CrossRef]
- Pedregosa, F.; Varoquaux, G.; Gramfort, A.; et al. Scikit-Learn: Machine Learning in Python. J. Mach. Learn. Res. 2011, 12, 2825–2830. [Google Scholar]
- Paszke, A.; Gross, S.; Massa, F.; et al. PyTorch: An Imperative Style, High-Performance Deep Learning Library. In Advances in Neural Information Processing Systems; 2019; Volume 32, pp. 8024–8035. [Google Scholar]
- Wan, J.; Yar, K.P.; Low, M.Y.H.; Du, C. Comparing Traditional Machine Learning and Deep Learning Methods for Imbalanced Vibration Signal-Based Tool Condition Monitoring. In Proceedings of the 2025 7th International Conference on Industrial Artificial Intelligence (IAI), Shenyang, China, 21–24 August 2025; IEEE: New York, NY, USA; 2025, pp. 1–6. [Google Scholar] [CrossRef]
- Hochreiter, S.; Schmidhuber, J. Long Short-Term Memory. Neural Comput. 1997, 9, 1735–1780. [Google Scholar] [CrossRef] [PubMed]
- Vaswani, A.; Shazeer, N.; Parmar, N.; Uszkoreit, J.; Jones, L.; Gomez, A.N.; Kaiser, Ł.; Polosukhin, I. Attention Is All You Need. In Advances in Neural Information Processing Systems; 2017; Volume 30, pp. 5998–6008. [Google Scholar]
- Friedman, J.H. Greedy Function Approximation: A Gradient Boosting Machine. Ann. Stat. 2001, 29, 1189–1232. [Google Scholar] [CrossRef]
- Chen, T.; Guestrin, C. XGBoost: A Scalable Tree Boosting System. In Proceedings of the 22nd ACM SIGKDD International Conference on Knowledge Discovery and Data Mining, San Francisco, CA, USA, 13–17 August 2016; pp. 785–794. [Google Scholar] [CrossRef]
Figure 1.
Overview of the method (values in (a)–(c) are illustrative). (a) Machining signals are recorded for every cut, whereas wear is measured only at inspections; in the hard-turning and PHM 2010 datasets, the readings between simulated inspections are withheld and used only for scoring. (b) Published approaches assign assumed wear values to the unmeasured cuts and fit each cut to them. Here, the GRU predicts a non-negative increment for each cut (Equation (1)); the increments are summed from the first measurement (Equation (2)), and only their sum over an inspection interval is compared with the measured change, in interval form (Equation (3)) or cumulative form (Equation (4)). (c) The online estimate restarts from each physical measurement (Equation (5)); after the next inspection, the predicted increments are rescaled to the measured change (Equation (6)). (d) Data splits, comparison methods and scores used in the evaluation.
Figure 1.
Overview of the method (values in (a)–(c) are illustrative). (a) Machining signals are recorded for every cut, whereas wear is measured only at inspections; in the hard-turning and PHM 2010 datasets, the readings between simulated inspections are withheld and used only for scoring. (b) Published approaches assign assumed wear values to the unmeasured cuts and fit each cut to them. Here, the GRU predicts a non-negative increment for each cut (Equation (1)); the increments are summed from the first measurement (Equation (2)), and only their sum over an inspection interval is compared with the measured change, in interval form (Equation (3)) or cumulative form (Equation (4)). (c) The online estimate restarts from each physical measurement (Equation (5)); after the next inspection, the predicted increments are rescaled to the measured change (Equation (6)). (d) Data splits, comparison methods and scores used in the evaluation.

Figure 2.
Flank wear measured after every cut for the 28 hard-turning runs, by cutting condition. The dashed line marks the 0.15 mm flank wear at which each run was stopped.
Figure 2.
Flank wear measured after every cut for the 28 hard-turning runs, by cutting condition. The dashed line marks the 0.15 mm flank wear at which each run was stopped.

Figure 3.
Cutting set-up, representative flank-wear image and inspection schedule. (a) Schematic of the PHM-AP 2025 cutting set-up and recorded signals. (b) Representative flank-wear microscope image from the hard-turning tests, reproduced from the ARTC project report [26] (200× magnification; scale bar, 0.2 mm). (c) PHM-AP 2025 physical inspections after Cuts 1, 6, 11, 16, 21 and 26; sensor and CNC operating records are available for every cut.
Figure 3.
Cutting set-up, representative flank-wear image and inspection schedule. (a) Schematic of the PHM-AP 2025 cutting set-up and recorded signals. (b) Representative flank-wear microscope image from the hard-turning tests, reproduced from the ARTC project report [26] (200× magnification; scale bar, 0.2 mm). (c) PHM-AP 2025 physical inspections after Cuts 1, 6, 11, 16, 21 and 26; sensor and CNC operating records are available for every cut.

Figure 4.
(a) RMSE on withheld cuts for the methods in Table 4. (b) RMSE when sensor groups are removed or used alone (Table 5). Unseen cutting condition, online estimation.

Figure 5.
One held-out run (the median-error run of the 28; unseen condition, inspection every 5 cuts): measured wear, the GRU online estimate and the rate carried forward.
Figure 5.
One held-out run (the median-error run of the 28; unseen condition, inspection every 5 cuts): measured wear, the GRU online estimate and the rate carried forward.

Figure 6.
(a) RMSE in the first interval of a new tool and in later intervals (post hoc analysis). (b) RMSE per held-out condition, GRU against the rate carried forward, inspection every 5 cuts.
Figure 6.
(a) RMSE in the first interval of a new tool and in later intervals (post hoc analysis). (b) RMSE per held-out condition, GRU against the rate carried forward, inspection every 5 cuts.

Figure 7.
Mean RMSE at the anchors after Cuts 6, 11, 16, 21 and 26, with each of the six tools held out in turn. Seeds are averaged within each held-out tool before the six-tool mean is calculated.
Figure 7.
Mean RMSE at the anchors after Cuts 6, 11, 16, 21 and 26, with each of the six tools held out in turn. Seeds are averaged within each held-out tool before the six-tool mean is calculated.

Table 1.
Training supervision and prediction outputs in published approaches most relevant to the present formulation.
Table 1.
Training supervision and prediction outputs in published approaches most relevant to the present formulation.
| Published approach | Training supervision or target construction | Prediction output | Difference from the present study |
| Learning from aggregate observations [16,17,18,19]; temporal disaggregation [20,21] | Group totals or means fitted directly (bag-level loss) or assigned to every member (instance-level loss); interval totals with related series | Individual-instance regression output | Not designed for ordered cuts, non-negative wear increments or a restart from each physical measurement; classical disaggregation is linear and does not constrain the sign of the increments. |
| Monotonic cumulative sequence prediction [11] | Wear values assigned to sequence positions, plus a monotonicity loss | Cumulative-wear sequence | Constrains output order but does not infer per-cut wear increments from measured interval totals. |
| Sparse-wear label expansion [3,4,5] | Fitted physical or numerical curves generate intermediate labels before model fitting | Per-cut or cumulative wear trained against generated labels | The present method leaves intermediate increments unobserved and uses only measured inspection-to-inspection changes as wear targets. |
| Semi-supervised wear learning [7,8] | A few measured cuts are labeled; unlabeled cuts enter through pseudo-labels or entropy-based training | Per-cut wear value or wear state | Unmeasured cuts receive model-generated values; measured changes between inspections are not used as constraints. |
| Mechanistic, physics-informed and staged-progression wear models [12,13,14,15] | Forces, geometry, temperature, wear equations, calibrated coefficients, or a logistic or staged progression enter the model or loss | Wear state, progression or tool-life class | Provides stronger mechanical content but requires temperatures, geometry or calibrated wear coefficients that are not available in the datasets used here. The logistic curve used for PHM-AP in this study only guides training and is not claimed as a wear law. |
| PHM-AP interval and pairwise regression [9,10] | Measured interval wear or differences between pairs of measured cuts | One wear change for an interval or a pair of measured cuts | Uses measured changes but does not estimate the wear increment of each cut inside an interval. |
| Present study | The sum of the predicted non-negative increments over each inspection interval is fitted to the measured wear change (bag-level loss); no intermediate wear values are assumed. | Per-cut wear increments and cumulative wear from a physical starting measurement | — |
Table 2.
The eight cutting conditions of the hard-turning dataset. Mean values are over the runs used.
Table 2.
The eight cutting conditions of the hard-turning dataset. Mean values are over the runs used.
| Condition | Speed (m/min) | Feed (mm/rev) | Depth of cut (mm) | Runs used | Mean cuts to 0.15 mm wear | Mean wear rate (µm/cut) |
| 1 | 100 | 0.1 | 0.1 | 4 | 17.5 | 7.3 |
| 2 | 100 | 0.1 | 0.2 | 3 | 18.7 | 7.1 |
| 3 | 100 | 0.2 | 0.1 | 4 | 36.5 | 3.5 |
| 4 | 100 | 0.2 | 0.2 | 3 | 34.7 | 3.5 |
| 5 | 140 | 0.1 | 0.1 | 4 | 18.8 | 6.9 |
| 6 | 140 | 0.1 | 0.2 | 3 | 17.0 | 7.6 |
| 7 | 140 | 0.2 | 0.1 | 3 | 30.3 | 4.3 |
| 8 | 140 | 0.2 | 0.2 | 4 | 24.5 | 4.9 |
Table 3.
Dataset roles and measurement structures.
| Dataset | Data and inspection structure | Feature processing and model | Validation objective |
| PHM-AP 2025 — training | Six tools, 26 cuts each; wear measured at Cuts 1, 6, 11, 16, 21 and 26. | Vibration, acoustic emission and CNC records; 64 selected features, 32-dimensional masked-autoencoder embedding, two-layer 64-unit GRU. | Development with genuinely sparse inspections; leave-one-tool-out comparison at the measured cuts, including adapted published methods. |
| PHM-AP 2025 — evaluation | Three later trajectories; Cut 1 wear available during inference; 14 further anchors released afterward. | PHM-AP configuration fixed before prediction; later measured anchors not used. | Check at the 14 wear values released after the configurations were fixed. |
| Hard-turning dataset | 28 complete runs across eight cutting conditions (of 32 planned); original wear measurement after every cut. | Force, tool/spindle vibration and acoustic emission; 32 per-cut features plus progress; two-layer 32-unit GRU. | Main evaluation: scoring against the withheld per-cut wear; leave-one-condition-out and leave-one-repeat-out; inspection every 5 or 10 cuts simulated. |
| PHM 2010 milling dataset | Three cutters (c1, c4 and c6), one cutting condition; original wear measurement after every cut. | Force, vibration and acoustic emission; per-cut features and GRU settings as for the hard-turning dataset. | Online check, leave-one-cutter-out, with inspection every 5 or 10 cuts simulated; comparison with inspection-only baselines. |
Table 4.
Mean RMSE of cumulative wear on withheld cuts of the 28 hard-turning runs; online estimation, unseen cutting condition. Five seeds are averaged within each run. Differences are means over runs; 95% intervals resample the eight conditions (5,000 resamples). Increment correlation is the mean of within-run Pearson correlations. A positive difference means a higher error than the GRU.
Table 4.
Mean RMSE of cumulative wear on withheld cuts of the 28 hard-turning runs; online estimation, unseen cutting condition. Five seeds are averaged within each run. Differences are means over runs; 95% intervals resample the eight conditions (5,000 resamples). Increment correlation is the mean of within-run Pearson correlations. A positive difference means a higher error than the GRU.
| Method | RMSE, every 5 cuts (µm) | RMSE, every 10 cuts (µm) | Difference from the GRU, every 5 cuts (µm) [95% CI] | Increment correlation (Pearson r), every 5 cuts |
| GRU (all inputs) | 4.4 | 7.7 | reference | 0.56 |
| GRU without sensors (progress input only) | 6.1 | 11.3 | +1.7 [0.5, 2.9] | 0.26 |
| Rate carried forward | 5.3 | 11.1 | +1.0 [−1.3, 3.1] | 0.13 |
| Linear additive model | 8.3 | 16.2 | +3.9 [1.8, 6.1] | 0.36 |
| Per-cut multilayer perceptron | 5.1 | 8.9 | +0.8 [−0.1, 1.8] | 0.45 |
| GRU, equal-split labels | 4.7 | 8.9 | +0.3 [0.0, 0.7] | 0.54 |
| GRU, PCHIP labels | 4.6 | 8.1 | +0.3 [−0.2, 0.9] | 0.58 |
| GRU, spline labels | 4.8 | 8.5 | +0.4 [−0.1, 1.0] | 0.56 |
| GRU, profile labels | 4.8 | 9.3 | +0.4 [−0.5, 1.4] | 0.49 |
Table 5.
Sensor groups removed or used alone; RMSE on withheld cuts, online estimation, unseen cutting condition. Intervals resample the eight conditions. A positive difference means a higher error than with all sensors.
Table 5.
Sensor groups removed or used alone; RMSE on withheld cuts, online estimation, unseen cutting condition. Intervals resample the eight conditions. A positive difference means a higher error than with all sensors.
| Inputs to the GRU | RMSE, every 5 cuts (µm) | RMSE, every 10 cuts (µm) | Difference from all sensors, every 5 cuts (µm) [95% CI] |
| All sensors and progress | 4.4 | 7.7 | reference |
| Without force | 4.7 | 8.4 | +0.3 [−0.1, 0.6] |
| Without spindle vibration | 5.3 | 8.5 | +0.9 [0.1, 2.5] |
| Without tool vibration | 4.4 | 7.7 | 0.0 [−0.2, 0.3] |
| Without AE | 4.4 | 7.6 | 0.0 [−0.5, 0.5] |
| Force only | 5.6 | 9.0 | +1.2 [0.4, 2.1] |
| Spindle vibration only | 6.9 | 13.8 | +2.5 [1.6, 3.4] |
| Tool vibration only | 5.8 | 10.3 | +1.4 [0.4, 2.5] |
| AE only | 6.6 | 13.2 | +2.2 [1.1, 3.4] |
| No sensors (progress input only) | 6.1 | 11.3 | +1.7 [0.5, 2.9] |
Table 6.
RMSE on withheld cuts by position in the run (post hoc analysis), online estimation, unseen cutting condition.
Table 6.
RMSE on withheld cuts by position in the run (post hoc analysis), online estimation, unseen cutting condition.
| Inspection | Part of the run | Withheld cuts | GRU (µm) | GRU without sensors (µm) | Rate carried forward (µm) |
| every 5 cuts | First interval of a new tool | 112 | 6.0 | 8.9 | 9.6 |
| every 5 cuts | Later intervals | 408 | 3.9 | 4.0 | 3.4 |
| every 10 cuts | First interval of a new tool | 252 | 10.6 | 14.1 | 15.1 |
| every 10 cuts | Later intervals | 331 | 6.8 | 7.2 | 5.7 |
Table 7.
RMSE (µm) on withheld cuts with inspection every 5 cuts: unseen against seen cutting conditions, online against after the next inspection.
Table 7.
RMSE (µm) on withheld cuts with inspection every 5 cuts: unseen against seen cutting conditions, online against after the next inspection.
| Method | Unseen condition, online (µm) | Unseen condition, after next inspection (µm) | Seen conditions, online (µm) | Seen conditions, after next inspection (µm) |
| GRU (all inputs) | 4.4 | 1.2 | 6.4 | 1.2 |
| GRU without sensors | 6.1 | 1.6 | 5.8 | 1.5 |
| GRU, equal-split labels | 4.7 | 1.2 | 6.3 | 1.2 |
| GRU, PCHIP labels | 4.6 | 1.1 | 6.3 | 1.1 |
| GRU, spline labels | 4.8 | 1.1 | 6.5 | 1.1 |
| GRU, profile labels | 4.8 | 1.3 | 7.1 | 1.3 |
| Rate carried forward (online) | 5.3 | – | 5.2 | – |
| Interpolation, PCHIP (after next inspection) | – | 0.9 | – | 0.9 |
| Denton disaggregation (after next inspection) | – | 0.9 | – | 0.9 |
| Chow–Lin disaggregation (after next inspection) | – | 1.1 | – | 1.1 |
Table 8.
Online checks on the two single-condition datasets: PHM-AP 2025 (six tools, leave-one-tool-out) and PHM 2010 (three cutters, leave-one-cutter-out). The worst value is taken over held-out tools or cutters. For PHM-AP, the GRU uses the hard-turning settings with fixed per-cut features (Section 3.5).
Table 8.
Online checks on the two single-condition datasets: PHM-AP 2025 (six tools, leave-one-tool-out) and PHM 2010 (three cutters, leave-one-cutter-out). The worst value is taken over held-out tools or cutters. For PHM-AP, the GRU uses the hard-turning settings with fixed per-cut features (Section 3.5).
| Dataset and schedule | Method | Mean RMSE (µm) | Worst-tool or worst-cutter RMSE (µm) |
| PHM-AP, first measurement only | GRU (all inputs) | 18.3 | 26.3 |
| PHM-AP, first measurement only | GRU without sensors | 11.6 | 15.7 |
| PHM-AP, first measurement only | Rate carried forward | 12.3 | 16.4 |
| PHM-AP, every 10 cuts | GRU (all inputs) | 14.1 | 20.9 |
| PHM-AP, every 10 cuts | GRU without sensors | 9.4 | 16.1 |
| PHM-AP, every 10 cuts | Rate carried forward | 10.2 | 16.7 |
| PHM 2010, every 5 cuts | GRU (all inputs) | 1.7 | 2.3 |
| PHM 2010, every 5 cuts | GRU without sensors | 1.3 | 1.4 |
| PHM 2010, every 5 cuts | Rate carried forward | 0.8 | 1.1 |
| PHM 2010, every 10 cuts | GRU (all inputs) | 3.4 | 4.7 |
| PHM 2010, every 10 cuts | GRU without sensors | 2.6 | 2.7 |
| PHM 2010, every 10 cuts | Rate carried forward | 2.1 | 2.9 |
Table 9.
RMSE at the anchors of the held-out tool for nine fitted methods (each of the six tools held out in turn).
Table 9.
RMSE at the anchors of the held-out tool for nine fitted methods (each of the six tools held out in turn).
| Method | Analysis and training target | Mean RMSE (µm) | Median RMSE (µm) | Worst-tool RMSE (µm) |
| GRU, development analysis | Development analysis; measured interval changes | 11.8 | 9.6 | 21.1 |
| Adapted Kunte–Manakari random forest | Published comparator; differences between pairs of anchors | 11.8 | 10.6 | 17.3 |
| Model-selection configuration | Model-selection analysis; measured interval changes | 12.2 | 9.7 | 20.4 |
| Convolutional recurrent sequence model | Development analysis; measured interval changes | 12.3 | 11.1 | 19.7 |
| Reconstructed-target XGBoost | Development analysis; reconstructed per-cut increments | 13.1 | 12.7 | 20.9 |
| Direct cumulative-wear random forest | Baseline; measured cumulative anchors | 14.8 | 16.1 | 22.7 |
| Histogram gradient boosting | Development analysis; reconstructed per-cut increments | 14.9 | 15.1 | 25.2 |
| Transformer | Development analysis; measured interval changes | 20.2 | 15.3 | 47.5 |
| Adapted Mielgo interval multilayer perceptron | Published comparator; five-cut interval wear | 41.0 | 39.7 | 73.3 |
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.
Copyright: This open access article is published under a Creative Commons CC BY 4.0 license, which permit the free download, distribution, and reuse, provided that the author and preprint are cited in any reuse.