Abstract
Statistical radiation dose-volume measures in radiotherapy treatment planning have been investigated for organs at risk but did not address target volumes. We explore their applicability to breast-integrated boost dose prescription in breast cancer. Four statistical metrics –mean absolute dose deviation, standard deviation, arithmetic mean, Gini coefficient– and five established homogeneity and conformity indices, totaling nine metrics, were retrospectively extracted from dose volume histograms of the breast and tumor targets in 42 breast cancer patients who received hypofractionated radiotherapy of 42 Gy to the breast with an integrated boost of 51 Gy to the tumor bed. The metrics were compared using Pearson pairwise correlation. The relationships among the metrics were evaluated by principal component analysis. The results displayed high collinearity among the metrics. The established homogeneity and conformity indices were in line with apparently acceptable treatment plans, but the arithmetic mean metric disclosed excess doses up to 2.5 Gy to the tumor bed, the breast or both in all patients save one. Thus, established indices did not detect excess doses. Statistical measures should be considered in the dosimetric analysis of breast-boost dose prescription.
Keywords:
arithmetic mean
; mean absolute dose deviation
; standard deviation
; dispersion
; Gini co-efficient
; conformity
; evenness
Copyright: This open access article is published under a Creative Commons CC BY 4.0 license, which permit the free download, distribution, and reuse, provided that the author and preprint are cited in any reuse.