Submitted:
20 November 2026
Posted:
24 November 2026
You are already at the latest version
Abstract
Selecting an interface for a piezoelectric harvester requires comparing circuits at the intended load while accounting for their component settings. This study compares a Schottky full bridge, self-powered synchronous electric charge extraction (SECE), and self-powered parallel synchronized switch harvesting on inductor (P-SSHI) supplied by a common prescribed source. A finite-element model of a polyvinylidene fluoride (PVDF) bimorph cantilever under 0.5 g base excitation defines a 50 Hz Norton equivalent for LTspice transient simulations. The analysis covers load resistance, the SECE transformer winding ratio and timing capacitance, and the P-SSHI timing capacitance and inversion inductance. Average load power is evaluated alongside settling, switching events, and selected component-terminal limits. Fixed reference configurations are used for the load comparison, while component sensitivity is assessed through single-parameter sweeps. At the 660 kΩ nominal load, the bridge, SECE, and P-SSHI deliver 227.9, 336.8, and 473.8 μW, respectively. SECE gives the highest power at 100 and 350 kΩ, whereas P-SSHI leads from 600 kΩ to 1.2 MΩ, above which its transistor voltage stress exceeds the selected 65 V limit. Electrical loading is not coupled back into cantilever motion. The results show that load, component settings, and component limits should be considered together when selecting an interface.
Keywords:
piezoelectric energy harvesting
; SECE
; P-SSHI
; interface circuit
; load resistance
; parametric analysis
; Norton equivalent model
1. Introduction
Piezoelectric harvesters can supply low-power wireless sensors and Internet of Things (IoT) devices by converting ambient vibration into electrical energy [1,2]. For such loads, the relevant output is the DC power delivered after rectification and conditioning [3]. This power depends on both the mechanical response of the harvester and the electrical interface, which has motivated integrated harvester and circuit designs [4,5,6]. Electromechanical models of piezoelectric beams with rectified loads describe how mechanical excitation and electrical loading interact [7]. Maximum power point tracking and dedicated switching-control circuits address the selection of the operating point and the timing of the switching pulses [8,9]. Interface selection therefore has to consider the source, the circuit, and the load together, including the effect of electrical loading on the coupled response [5,7,10].
Three established interface approaches are passive full-bridge rectification, synchronous electric charge extraction (SECE), and synchronized switch harvesting on inductor (SSHI) [11]. Electrically, the piezoelectric element acts as a current source shunted by its internal capacitance. In a full bridge, current reaches the output only while the terminal-voltage magnitude exceeds the rectified output voltage plus the diode forward drops, and the charge required to swing the internal-capacitance voltage between the two conduction thresholds in each half-cycle does not reach the load [3,11]. SECE extracts the charge accumulated on the piezoelectric capacitance near each voltage extremum and transfers its energy to the load through an inductive stage [12]. SSHI briefly connects an inductor to the piezoelectric capacitance near each voltage extremum, so that the resulting LC oscillation reverses the terminal voltage [13]. In parallel SSHI (P-SSHI), the switched inductor is placed across the piezoelectric element ahead of the rectifier. Self-powered hybrid circuits combine SECE and SSHI to balance peak output power and rectified-voltage range [14]. Circuit comparisons have been reported for frequency up-conversion [15] and impact excitation [16], while hybrid S-SSHI/SECE rectifiers [17] and self-powered SECE under shock excitation [18] address further operating conditions. Because the excitation, source, and output conditions differ among these studies, their reported power levels apply to each operating regime and cannot be compared directly [11,15,16,17,18]. The question considered here is therefore which topology-component combination delivers usable DC power at the intended load when all interfaces are driven by the same source.
This study compares a Schottky full bridge, self-powered SECE, and self-powered P-SSHI driven by a common 50 Hz Norton source derived from a finite-element model of a fabricated PVDF bimorph cantilever. The load comparison evaluates the delivered DC power over a common set of load resistances with fixed reference component settings. Separate parameter studies assess the sensitivity of the synchronized interfaces to their switching components. A simulated operating point is included in the comparison only if its power has settled, one switching event occurs per source half-cycle in the synchronized interfaces, and selected component limits are met. The results support load-specific interface selection within the prescribed electrical source model, which does not include feedback of electrical loading into the cantilever motion. Building on the earlier interface comparisons discussed above, this work combines identical prescribed source parameters, modeled self-powered control consumption, and selected component-stress screens in one load-dependent assessment. The focus is on fixed circuit implementations, with component-sweep maxima reported separately, so the comparison does not imply a universal ranking of the interface principles.
2. Materials and Methods
2.1. Finite-Element Model of the Piezoelectric Harvester
A PVDF/steel/PVDF bimorph cantilever prototype was fabricated with a nominal cantilever length of 18.3 mm and an 8.5 g steel proof mass at the free end. The laminate consisted of a 0.1 mm steel substrate and two 30 m PVDF layers. The COMSOL model was developed from this prototype, and its geometric and operating parameters were established through measurements and experimental tests on physical cantilevers. The harvester was represented by a two-dimensional plane-strain model in COMSOL Multiphysics 6.4 (Build 293) and characterized under 0.5 g harmonic base excitation near 50 Hz. Its modal, frequency-domain, and resistive-load responses provided the basis for the electrical source model. Previous PVDF modeling has incorporated experimentally determined damping parameters [19], whereas the present model used prescribed loss factors. The proof mass was included to lower the natural frequency, following the design principle discussed in [20]. The clamped end was fixed, and a transverse inertial body load represented the base acceleration. Separate eigenfrequency and frequency-domain studies identified the first bending mode and the frequency of the largest sampled electrical response. Figure 1 shows the geometry.
Mechanical losses were represented by isotropic loss factors of 0.01 for steel and for PVDF. These user-defined coefficients are prescribed model inputs, not independently identified material loss factors. Their relative magnitudes should not be interpreted as a measured comparison of steel and PVDF damping; calibration against the assembled cantilever response remains necessary. The PVDF layers used an anisotropic stress-charge constitutive relation, a density of 1780 kg/m3, and the Material XZ-plane coordinate system. The PVDF constitutive data correspond to the predefined COMSOL Multiphysics 6.4 Piezoelectric material-library entry for PVDF. In material axes and Voigt notation, the symmetric stiffness matrix has , , , , , and GPa, with all other independent entries zero. The only nonzero piezoelectric stress coefficients are , , and C/m2. The relative permittivity at constant strain is diagonal, with , , and . The steel was modeled with a Young’s modulus of 200 GPa, a Poisson’s ratio of 0.30, and a density of 7850 kg/m3 at 293.15 K. An out-of-plane thickness of 68 mm represented the cantilever width. Both PVDF layers shared a circuit terminal and ground, which connected them in parallel to the external resistive load. The frequency-domain study covered 45-55 Hz in 0.05 Hz increments at 630 k. Free triangular meshes contained 7962 elements for the eigenfrequency solution and 8185 for the frequency-domain solution.
Separate parameter sweeps examined cantilever length from 17.50 to 19.50 mm, PVDF-layer thickness from 10 to 50 m, and proof-mass density from 5000 to 10,000 kg/m3, in increments of 0.01 mm, 1 m, and 100 kg/m3, respectively. Each sweep used 50 Hz excitation, 0.5 g acceleration, and a 630 k load, with the other parameters held at their nominal values. Proof-mass geometry remained fixed during the density sweep, so this sweep varied the proof mass. Experiments on ferroelectret polypropylene harvesters have also demonstrated mass-dependent frequency and power responses [21]. In the present sweeps, the largest sampled powers occurred at 18.28 mm, 32 m, and a density corresponding to 8.49 g. The prototype’s nominal values of 18.3 mm, 30 m, and 8.5 g were retained for the reference configuration. Those values are close to the separate sampled maxima, but the one-parameter sweeps do not establish a joint optimum. A load sweep then sampled 901 logarithmically spaced resistances from 1 to 1 G at 50 Hz with the nominal mechanical configuration fixed. Voltage, current, and average load power defined the electrical operating point. Table 1 lists the reference parameters, including the rounded 660 k load derived in Section 2.2, where the FEM electrical response is converted into the prescribed Norton source used to compare the interfaces.
Figure 1.
Two-dimensional FEM geometry of the PVDF/steel/PVDF bimorph cantilever and proof mass. The individual laminate layers are not resolved at this scale.
Figure 1.
Two-dimensional FEM geometry of the PVDF/steel/PVDF bimorph cantilever and proof mass. The individual laminate layers are not resolved at this scale.

2.2. Electrical Source Model and Interface-Circuit Topologies
For the interface comparison, the 50 Hz FEM electrical response was represented in LTspice by the common Norton source in Figure 2a, i.e., a sinusoidal current source with peak amplitude shunted by the piezoelectric capacitance and an equivalent parallel resistance [22]. A 10 FEM load approximated short-circuit operation, while 100 M approximated open-circuit operation. Both and were selected by fitting the Norton model to the FEM voltage, current, and resistive-load response at 50 Hz. Here, is an effective parallel resistance of the fitted equivalent circuit and is not interpreted as an independently determined material leakage resistance. The FEM characterization gave a near-short-circuit peak current of 48.77 A and a near-open-circuit peak voltage of 32.14 V. The calibrated source uses nF and M, which give a source-impedance magnitude k at rad/s, consistent with . Table 2 lists these parameters. The source is prescribed, so circuit loading is not fed back into the cantilever motion. The current-source amplitude therefore remains fixed for all interfaces, although their different terminal-voltage trajectories can lead to different electrical input powers.
Figure 2.
Circuit models used in this study: (a) Norton source; (b) DFLS2100 full bridge; (c) SECE power stage based on [23]; (d) P-SSHI adapted from [24].

The full bridge in Figure 2b follows the standard passive rectification arrangement [3]. For either input polarity, a diode pair conducts when the magnitude of the piezoelectric terminal voltage exceeds the output voltage plus the pair’s forward drops. This charges and supplies . The present implementation uses four DFLS2100 Schottky models without active switching control. The transformer-coupled stage in Figure 2c applies the synchronous charge-extraction principle of Lefeuvre et al. [23]. Turning on the MOSFET near a voltage extremum discharges through the input bridge and the primary winding and stores energy in its magnetic field. When the MOSFET turns off, the secondary winding transfers energy through D5 to and . Self-powered SECE has also been reported by Qiu and Liang [25]. The implementation used here combines this extraction stage with a harvested 3 V supply, voltage-change detection, RC pulse generation, and supervisory enable logic. Its device models and component settings are specified in Section 2.3. The P-SSHI circuit in Figure 2d is adapted from the two-breaker arrangement of Liu et al. [24]. Complementary transistor pairs handle opposite voltage extrema and briefly connect across the piezoelectric element to reverse the voltage on . This study uses the prescribed Norton excitation, DFLS2100 rectification, BC856B/BC546B transistor models, and the component values in Section 2.3. The implementation includes detector-isolation resistors and reverse base-emitter clamps. Ben Ammar et al. [26] describe a related self-powered P-SSHI circuit with comparator-controlled switches and MOSFET rectification, which differs from the transistor-breaker circuit used here.
Figure 3 shows the sensing and pulse-generation circuits used to control the SECE stage. In Figure 3a, C3 and R2 form a high-pass network that responds to changes in the rectified voltage at N001, which is also labeled in Figure 2c. Its output crosses VREF when the slope of the rectified voltage changes sign, so the TLV3691 changes its output at N007 near each voltage extremum. RPROT limits input current, and the BAS116 diodes clamp the comparator input relative to VREF. The reference divider is supplied from the harvested 3 V rail N004. In Figure 3b, an edge from the first inverter is coupled through to TIM_IN, which returns to N004 with the time constant s. The second, Schmitt-trigger inverter converts this transient into the signal PULSE. The AND gate passes this pulse only when the supply supervisor asserts PGOOD. The output drives the extraction MOSFET through RGATE at N008, the gate node shown in Figure 2c. The gate pull-down holds the MOSFET off when no pulse is applied. Thus, the detector sets the switching instant, the RC network sets the pulse duration, and the supervisor enables switching after the control supply exceeds its threshold.
For a Norton source connected directly to a purely resistive load, maximum load power occurs at [22]. The 659 k impedance is consistent with the FEM load-sweep maximum at 660.7 k. A rounded 660 k value is therefore used as the nominal reference load. The 630 k reference used in the FEM frequency-domain characterization is retained in the component studies, whereas the nominal 660 k comparison load follows the calibrated source impedance. The calculated Norton maximum is 383 W for direct resistive loading, in agreement with the 382.1 W FEM maximum (Section 3.1). This value applies to that load class and does not bound the output of nonlinear switching interfaces. The common-load comparison includes the 660 k nominal load as a simulated point and extends from 100 k to 1.8 M.
Figure 3.
SECE sensing and gate-control circuits: (a) voltage-change detection, input protection, and reference bias; (b) RC pulse generation and PGOOD-gated MOSFET drive.
Figure 3.
SECE sensing and gate-control circuits: (a) voltage-change detection, input protection, and reference bias; (b) RC pulse generation and PGOOD-gated MOSFET drive.

2.3. Interface-Circuit Modeling Parameters
The reference circuits use the source parameters in Table 2, 50 Hz excitation, F, and a simulation temperature of 27 °C. The passive bridge and P-SSHI rectifier use nonlinear DFLS2100 Schottky models rated at 100 V reverse voltage. The SECE secondary uses a BAS21H model rated at 200 V. Table 3 lists the reference settings, which remain fixed in the common-load comparison. The 1:1 SECE transformer and 470 H P-SSHI inductor were retained to compare fixed reference implementations across loads, with higher powers from the single-parameter sweeps reported separately because those sweeps do not establish jointly optimized configurations. Component variations and selected terminal checks are specified in Section 2.4. Control-model limitations are discussed in Section 3.5.
The SECE reference uses mH, , coupling coefficient , and primary and secondary winding resistances of 26.4 and 5.9 , respectively. The winding resistances are prescribed loss parameters retained from the reference LTspice netlist, rather than verified DCR values for a selected physical transformer. Their asymmetry is a modeling assumption requiring hardware validation. A ZVN4424A model represents the 240 V extraction MOSFET. The harvested control supply includes a DFLS2100 feeder, a BZT52C47 clamp, a BSS159N preregulator model, and a functional TPS7A0230 3 V LDO model. The Figure 3 detector uses C3 = 1.5 nF, R2 = 10 k, a 1 M input-protection resistor RPROT, BAS116 clamps, and an explicit 3 pF input capacitor CIN. Two 10 M resistors and a 100 nF capacitor set VREF to 1.5 V and filter it. A TLV3691 transient model represents the comparator. The pulse and enable blocks use functional SN74AUP2G14, SN74AUP1G08, and TPS3839L30 models. The reference pulse network uses pF, k, 680 timing-drive and gate resistors, BAT54 timing clamps, and a 10 M gate pull-down.
The P-SSHI reference uses BC856B/BC546B device models, H, and equal timing capacitors pF. The inductor model includes 2.8 series resistance, 144.77 k parallel resistance, and 3.37 pF parallel capacitance. These parasitic values remain fixed during the inductance study. Two 100 k resistors isolate the detectors from the inversion transient, and DFLS2100 diodes clamp reverse base-emitter voltage. Together with and , the isolation resistors set a nominal detector time constant of 15 s. The ideal LC half-period is 4.73 s, compared with the 10 ms source half-period.
2.4. Simulation Procedure and Output-Power Metrics
Transient simulations in LTspice 26.0.1 use the FEM-derived Norton source described in Section 2.2. The common-load comparison uses 12 resistances of 100, 350, 600, 660, 700, 1000, 1200, 1250, 1275, 1350, 1500, and 1800 k, which gives 36 distinct circuit-load settings with unchanged reference components. Reference runs start with discharged capacitors, and the output time constant ranges from 0.1 to 1.8 s. Runs at 100-660 k, the bridge and SECE runs at 700 k, and the SECE run at 1 M use 8 s and compare average load power over 6-8 s with 4-6 s. The P-SSHI 700 k case and the remaining runs at 1-1.8 M use 20 s, comparing 18-20 s with 16-18 s. Run duration is extended if needed until adjacent final 2 s powers differ by less than 0.1%. Maximum time steps for the higher-load simulations are 50 s for the bridge, 5 s for SECE, and 10 s for P-SSHI, and LTspice reduces the step further during switching transients. The P-SSHI cases at 1.2 and 1.25 M are repeated at 5 s. SECE normally uses trapezoidal integration. A run with convergence warnings is retained only as a numerical diagnostic and repeated with the alternate solver and Gear integration at unchanged component values. Displayed values are rounded, while calculations retain the full data precision.
The SECE winding-ratio study tests , 0.25, 0.5, 1, 2, 4, and 10 at H, 1 mH, and 10 mH, with k and pF. At 500 H and 1 mH, eight further ratios of 0.35, 0.75, 1.25, 1.5, 2.25, 2.5, 3, and 3.5 give 37 ratio cases in total. The model sets while holding coupling and winding resistances fixed. The timing study tests 21 values from 200 to 2000 pF, including 330 pF, at 100, 200, 630, and 1000 k with a 1 mH, 1:1 transformer. Each load uses the same grid, including 200, 250, 275, 300, 330, 350, 375, 400, 450, and 500 pF near the power peak. This gives 84 timing settings and, with one shared case, 120 distinct SECE parameter settings. These runs use stored controller states and initialized output voltages and therefore do not qualify discharged startup. They use a 5 s maximum step, the alternate solver, and Gear integration. Run duration increases from 2 to 4, 8, or 16 s as needed. Adjacent final 0.5 s power windows must differ by no more than 0.1% of the final-window power or 0.01 W, whichever is larger. The 200, 330, and 500 pF cases at 630 k are repeated. Checks with a 1 s maximum step cover 300, 330, and 350 pF at 630 k and the setting with the largest accepted sampled power at each of the other three loads. These nine verification runs are excluded from the count of distinct settings. Gate-pulse duration is measured between the 2.5 V crossings of the gate signal. P-SSHI studies test 18 equal timing capacitances from 100 to 2000 pF at 630 k and nine inductances from 10 H to 10 mH at 100, 200, 630, and 1000 k. They use 8 or 20 s runs, a 50 s maximum step, and adjacent final 2 s power windows with relative change below 0.1%. Average load power is calculated using Equation (1):
where is the start of the averaging interval, is its duration, and and are the load voltage and current. The reported powers use the final settling window of each run as the averaging interval. The load voltage is labeled in Figure 2 and in Figure 5. For a resistive load, the integrand equals . Independent integration is compared with the LTspice average-power measurement. Using the same averaging window, mean power delivered by the ideal Norton current source is , where and is positive into terminal A. Net interface input power is , where excludes currents through the Norton-model shunt branches and . The difference between these powers accounts for dissipation in and the change in energy stored in over the averaging window.
For SECE and P-SSHI, acceptance of component-study and extended-load points requires settled power, selected terminal limits, and one extraction or significant inversion event per complete source half-cycle. Bridge points require settled power and selected voltage limits. The P-SSHI transistor screens correspond to the BC546B/BC856B absolute maximum ratings of 65 V collector-emitter voltage, 80 V collector-base voltage, and 100 mA collector current. For SECE, the component-study peak screening thresholds are 240 V for and 40 V for of ZVN4424A; 60 V and 20 V, respectively, for BSS159N; 6 V at the LDO input; 3.6 V on the regulated supply; 50 V across the output capacitor; 100 V across sensing capacitor C3; 140 and 325 mA for the primary and secondary winding currents, respectively; 200 V reverse voltage for BAS21H; and 100 V reverse voltage for the DFLS2100 bridge and feeder diodes. Extended-load checks additionally impose 50 V across the reference and timing capacitors, 85 V reverse voltage on the BAS116 sensing clamps, and 30 V reverse voltage on the BAT54 timing clamps. These peak checks cover the full recorded transient. The winding-current thresholds are prescribed model screens, not validated transformer saturation ratings. A SECE case is accepted only if all applicable electrical screens and the settling, event-count, and numerical-consistency checks pass. SECE gate pulses are counted at 2.5 V. Accepted SECE runs have no numerical warnings and a difference below 1 nW between independently integrated power and the LTspice measurement. P-SSHI current lobes are identified above 1 mA within the first 6 ms of each 10 ms source half-cycle. A lobe is significant when its peak magnitude exceeds both 2 mA and 20% of the peak magnitude of the first lobe in the same half-cycle. Cases without confirmed steady operation are omitted from power curves. In Figure 8, Figure 9 and Figure 10, each series is normalized by its largest accepted sampled power. In Figure 6, Figure 7, Figure 8, Figure 9, Figure 10, Figure 11 and Figure 12, markers denote samples and straight segments connect adjacent accepted points to guide the eye. The segments do not represent additional simulated points or a continuous optimum. In Figure 11 and Figure 12, unconnected crosses identify settled stress diagnostics that exceed selected component limits. Their powers are excluded from the accepted operating curves and topology ranking. The comparison screen is asymmetric: it rejects P-SSHI transistor rating violations but excludes the SECE RESET-current limit. Thus, accepted denotes inclusion under the stated simulation criteria, not compliance with all component ratings; SECE comparisons remain conditional on this unresolved controller limitation (Section 3.5).
3. Results and Discussion
3.1. Harvester Characterization and Equivalent-Model Assessment
The first complex eigenfrequency was Hz. Its real part identifies the modal frequency, while the imaginary part reflects the damping and corresponds to a modal damping ratio of approximately 0.5%, consistent with the prescribed loss factors. In the frequency sweep at k, the largest sampled electrical response occurred at 49.9 Hz, with a peak voltage of 22.86 V and an average load power of 414.6 W. At the nominal 50 Hz, the corresponding values were 21.93 V and 381.7 W. The 6.1% separation between the modal frequency and the sampled response maximum remains unresolved. Figure 4 therefore presents the mode shape and the electrical response of the numerical model without identifying 49.9 Hz as a verified physical resonance.
At 50 Hz, the resistive-load sweep gave a largest sampled average power of 382.1 W at 660.7 k, with peak voltage and current amplitudes of 22.47 V and 34.01 A. The 659 k Norton impedance is within 0.3% of this resistance, which confirms the internal consistency of the 50 Hz calibration. However, a mesh-sensitivity check at this frequency and load changed the average power from 382.1 to 289.6 W as the mesh increased from 8185 to 81,693 elements, a decrease of 24.2%. Mesh convergence of the electrical output has therefore not been established. The 50 Hz values define a prescribed Norton source for the circuit comparison rather than validated predictions of harvester output, and the circuit results describe interface behavior for the source parameters in Table 2.
3.2. Time-Domain Operation of the SECE and P-SSHI Interfaces
Figure 5 compares the settled time-domain behavior of the two synchronized interfaces at k. In SECE, the piezoelectric voltage builds to about 47 V in magnitude, remains nearly constant from about 7.7 ms until the extraction near 10.4 ms, and falls close to zero during each energy-extraction event. This plateau is consistent with the BZT52C47 clamp limiting the rectified high-voltage control-supply rail; the piezoelectric-terminal voltage also includes the bridge and feeder-diode drops. This branch draws an average of 271.4 W over 6-8 s, including clamp dissipation and preregulator input power, so diversion of energy into this branch contributes to the relatively low load power in this SECE implementation. The primary and secondary current pulses show the brief transfer of energy through the transformer. Two extraction events occur in the displayed 20 ms window, one per source half-cycle. The output capacitor maintains the load voltage near 14.9 V. Average load power over the final 6-8 s interval is 336.8 W.
Figure 4.
COMSOL results: (a) first bending mode with displacement normalized to its maximum and magnified deformation; (b) peak voltage and average load power versus frequency at k.
Figure 4.
COMSOL results: (a) first bending mode with displacement normalized to its maximum and magnified deformation; (b) peak voltage and average load power versus frequency at k.

Figure 5.
SECE and P-SSHI waveforms at k: (a) SECE voltages; (b) SECE transformer currents; (c) P-SSHI voltages; (d) P-SSHI inversion-inductor current. Time is relative to each displayed window.
Figure 5.
SECE and P-SSHI waveforms at k: (a) SECE voltages; (b) SECE transformer currents; (c) P-SSHI voltages; (d) P-SSHI inversion-inductor current. Time is relative to each displayed window.

In P-SSHI, the piezoelectric voltage is inverted rather than discharged at each switching event. During each brief pulse of inversion-inductor current, the terminal voltage changes from about 17.5 V to about 12.6 V of opposite sign, which corresponds to an inversion factor of approximately 0.7. Four inversion events occur in the displayed 40 ms window, again one per source half-cycle. The output voltage remains near 17.7 V, and average load power over the final 6-8 s interval is 473.8 W.
3.3. Component and Load Parametric Analysis
The following studies examine load dependence and component sensitivity with one parameter varied at a time. The common-load comparison uses fixed reference settings. Component-study maxima are reported separately. Power is evaluated together with the settling, switching, and selected terminal criteria defined in Section 2.4.
3.3.1. SECE Parameter Sensitivity
With the reference SECE circuit, load power is 320.7 W at 100 k and reaches the largest of the five values shown in Figure 6 at 350 k, where it is 338.0 W. Power then decreases to 337.4 W at 600 k, 336.8 W at 660 k, and 336.3 W at 700 k. The four values from 350 to 700 k span 0.5% of the 350 k value. These samples indicate weak load dependence over this range for the present circuit and prescribed source, consistent with the SECE principle [23]. They do not locate the exact load-power maximum or establish universal SECE load independence.
Figure 6.
SECE load power at five loads from 100 to 700 k.

At k, Figure 7 contains 11 accepted winding-ratio points for 500 H and 12 for 1 mH. Power increases across the accepted samples, reaching 307.3 and 371.9 W, respectively, at . These are the largest accepted sampled powers. Both curves are still rising at this ratio, so an interior optimum is not established. At every winding ratio accepted in both series, the 1 mH primary gives higher load power. Of the 37 ratio cases, 23 are accepted. Ten settled cases fail switching or selected terminal criteria, and four 10 mH cases at , 0.25, 0.5, and 4 reach the time limit without confirmed steady periodic operation. In the same 10 mH series, and 2 fail the switching criterion, while fails selected terminal limits. No 10 mH point is accepted, so this series is omitted from Figure 7. The 330 pF timing setting was selected with the 1 mH transformer, so the 500 H and 10 mH series are evaluated without timing re-adjustment. Here at 10 mH, the extraction pulse is much shorter than the 10.9 s quarter period . Because the secondary winding resistance is held fixed while scales with , the rise of power with n may partly reflect this simplification. The 1 mH, 1:1 transformer remains the fixed reference for the common-load comparison. Physical transformer size remains a practical design consideration [27].
Figure 7.
SECE load power versus transformer winding ratio at k for accepted 500 H and 1 mH cases.

The SECE timing capacitance sets the extraction-pulse duration. Figure 8 compares separately normalized power at four loads with a 1 mH, 1:1 transformer. Each series contains 21 tested capacitances from 200 to 2000 pF, including ten points over 200-500 pF. The closely spaced samples resolve a high-power region near 300-330 pF, with a steeper decline toward 200 pF than toward 500 pF. The largest sampled powers are 320.9 W at 330 pF for 100 k, 333.9 W at 300 pF for 200 k, 338.3 W at 300 pF for 630 k, and 333.7 W at 300 pF for 1000 k. The 330 pF reference is within 0.54% of the largest sampled power in every series. These samples do not establish an exact continuous optimum. All 84 timing settings meet the comparison criteria. At 630 k, gate pulses last 2.0 s at 300 pF and 2.3 s at 330 pF. Repeating the 200, 330, and 500 pF cases at this load gives identical average powers. Reducing the maximum time step from 5 to 1 s at the tested power maximum of each load, and at 330 and 350 pF for 630 k, changes power by less than 0.02%. The 330 pF setting remains fixed in the common-load comparison.
Figure 8.
Normalized SECE load power versus timing capacitance at four loads, with mH. The inset shows the 200–500 pF region for all four series. Dashed vertical lines mark the 330 pF reference.
Figure 8.
Normalized SECE load power versus timing capacitance at four loads, with mH. The inset shows the 200–500 pF region for all four series. Dashed vertical lines mark the 330 pF reference.

The winding-ratio and timing studies share one case at mH, pF, and k. Together, they contain 120 distinct parameter settings, of which 106 meet the criteria in Section 2.4. Their sampled maxima apply to the prescribed source and fixed parasitic values. Combined transformer and timing optimization and hardware validation remain outside the scope of these simulations.
3.3.2. P-SSHI Parameter Sensitivity
The equal timing capacitances and the isolation resistances set the detector timing. Switching delay affects the performance of self-powered P-SSHI interfaces [28]. At k and H, the 18 tested capacitances range from 100 to 2000 pF, corresponding to nominal detector time constants from 10 to 200 s. The largest sampled power is 457.0 W at 200 pF, compared with 455.9 W at the 150 pF reference, a difference of 1.1 W or 0.24% of the sampled maximum. Power decreases to 283.7 W at 2000 pF. All 18 cases meet the comparison criteria. Figure 9 normalizes power by the sampled maximum. The 150 pF reference remains fixed in the common-load comparison.
Figure 9.
Normalized P-SSHI load power versus equal timing capacitances at k and H. The dashed line marks the 150 pF reference.
Figure 9.
Normalized P-SSHI load power versus equal timing capacitances at k and H. The dashed line marks the 150 pF reference.

With pF, nine inversion inductances from 10 H to 10 mH were tested at each of four loads. Of the 36 cases, 30 meet the comparison criteria. Their sampled maxima are 84.4 W at 1 mH for 100 k, 166.8 W at 10 mH for 200 k, 472.7 W at 2 mH for 630 k, and 651.9 W at 2 mH for 1000 k. At 200 k, the largest value occurs at the upper end of the tested inductance range, so an interior optimum is not established. Inductance governs voltage inversion together with circuit losses [26]. Series resistance, parallel resistance, and parallel capacitance remain fixed, so larger inductances benefit from a higher characteristic impedance relative to the fixed 2.8 series resistance. This makes the study one of electrical parameter sensitivity rather than selection among physically corresponding inductors.
Figure 10 shows the cases that meet the criteria, with each load series normalized by its own largest accepted power. The 10 H case at 630 k and the 10, 47, and 100 H cases at 1000 k fail selected terminal limits. At 100 k, the 2 and 10 mH cases pass those limits but fail the current-lobe criterion. This exclusion does not by itself demonstrate absent voltage inversion. In the 2 mH case, all 199 examined half-cycles contain a recorded voltage polarity reversal, while current-lobe peaks of 1.98–2.03 mA straddle the 2 mA counting threshold. The 1 mH maximum reported at 100 k therefore depends on this screening rule. The 470 H setting remains the fixed reference for the common-load comparison.
Figure 10.
Normalized P-SSHI load power versus inversion inductance at four loads with pF. Only accepted cases are shown.
Figure 10.
Normalized P-SSHI load power versus inversion inductance at four loads with pF. Only accepted cases are shown.

With the 470 H and 150 pF reference settings, load power increases from 84.0 W at 100 k to 271.8 W at 350 k, 437.5 W at 600 k, 473.8 W at 660 k, and 496.6 W at 700 k. Power reaches 629.6 W at 1 M and 695.6 W at 1.2 M (Figure 11). The accepted curve contains seven load points and ends at 1.2 M. The five larger-load points are shown separately because they exceed selected component limits. A load-power maximum is not established before these limits are reached. Figure 12 shows the fixed-component comparison of all three interfaces over the full load range.
Figure 11.
P-SSHI load power versus load resistance for H and pF. Crosses mark points that exceed selected component limits.
Figure 11.
P-SSHI load power versus load resistance for H and pF. Crosses mark points that exceed selected component limits.

The P-SSHI reference circuit gives its largest accepted sampled power of 695.6 W at 1.2 M. At this load, the largest transistor collector–emitter voltage is 64.0 V. The next sampled load of 1.25 M reaches 66.1 V and fails the selected 65 V screen. Repeating both bracket endpoints with a 5 s maximum step changes load power by less than 0.1% and leaves their acceptance classifications unchanged. The 1.8 M trial gives 827.3 W but reaches 86.2 V and 102.4 mA, exceeding the selected 65 V and 100 mA limits. These rejected points appear as unconnected stress diagnostics in Figure 11 and Figure 12. The sampled bracket does not establish an exact maximum permissible load or complete hardware qualification.
3.4. Load-Dependent Comparison of the Interfaces
Figure 12 compares the three reference interfaces at 12 common resistances from 100 k to 1.8 M. Both synchronized interfaces exceed the bridge output wherever their operating points meet the comparison criteria, although the P-SSHI margin is small at 100 k. SECE gives the highest power at 100 and 350 k. P-SSHI leads from 600 k through 1.2 M among accepted reference points. The ranking change between SECE and P-SSHI therefore remains bracketed by 350 and 600 k, without locating an exact crossover. The bridge reaches its largest sampled power of 239.2 W at 1 M and decreases to 221.7 W at 1.8 M. This agrees with the ideal-bridge relations M and W [23], of which the simulated maximum reaches 96%. SECE reaches its largest sampled power of 338.0 W at 350 k, which is 34% of the ideal SECE value mW [23]. P-SSHI reaches 695.6 W at its highest accepted sampled load of 1.2 M. At the larger tested loads of 1.25-1.8 M, P-SSHI fails selected component limits. SECE remains accepted under the comparison criteria throughout this range and exceeds the bridge output.
The P-SSHI limit is reached as increasing load resistance raises the modeled output voltage and transistor voltage stress. Between 1.2 and 1.25 M, the output-voltage peak rises from 28.9 to 29.8 V, while the largest collector-emitter voltage rises from 64.0 to 66.1 V, i.e., to about 2.2 times the output voltage in both cases. At 1.25 M, Q4 exceeds the selected 65 V limit, although all peak collector currents remain below 100 mA. Voltage stress therefore limits the accepted sampled range before the current screen is exceeded. At 1.8 M, Q1 and Q4 exceed the voltage limit, while Q2 and Q3 exceed the current limit (Section 3.3.2). Thus, the increasing P-SSHI power curve is truncated by the selected component limits before a load-power maximum is established. The rejected points are stress diagnostics and cannot be ranked as usable output.
Figure 12.
Load power at fixed reference component settings. Crosses mark settled P-SSHI points that exceed selected component limits.
Figure 12.
Load power at fixed reference component settings. Crosses mark settled P-SSHI points that exceed selected component limits.

At 660 k, the bridge, SECE, and P-SSHI deliver 227.9, 336.8, and 473.8 W, respectively. Over the same 6-8 s interval, the mean powers delivered by the ideal Norton current source are 241.8, 876.1, and 538.9 W, while the corresponding net interface input powers are 237.3, 834.6, and 527.5 W, respectively. SECE and P-SSHI therefore deliver 1.48 and 2.08 times the bridge output. The 660 k point is the optimum for direct resistive loading (Section 2.2), not for the rectifying interfaces, whose sampled optima lie at other loads. Each interface uses one fixed component configuration throughout this comparison. Maxima from the separate component studies are not substituted for these reference settings. The reported ratios compare load power and are not conversion efficiencies. Identical Norton source parameters do not impose equal electrical input power, because each interface changes the piezoelectric-terminal voltage and the energy drawn from the source. The results describe simulated DC load power for the prescribed 50 Hz source and reference component models.
3.5. Design Implications
The results support comparing interfaces at the intended load with explicit component settings. The common Norton parameters provide a consistent electrical benchmark, while the modeled terminal voltage and input power remain specific to each interface. Consequently, the observed ranking reflects the combined effects of load, control-supply overhead, energy-transfer losses, and the selected operating limits, rather than output-power maxima alone. Separate component sweeps describe sensitivity within the investigated ranges. They do not establish a jointly optimized topology-component combination. Reported optima can also depend on the screening rules: the P-SSHI inductance maximum at 100 k depends on the 2 mA current-lobe criterion (Section 3.3.2), so rejection by this rule alone does not demonstrate failed voltage inversion. Because the magnetic sweeps hold parasitic values fixed, they do not represent a set of physically corresponding transformers or inductors and are likely to favor higher winding ratios and larger inversion inductances. Transformer size remains a practical constraint [27]. Component ratings bound the usable operating range: in P-SSHI, the largest collector–emitter voltage is about 2.2 times the output voltage (Section 3.4), so the 65 V transistor rating corresponds to an output voltage of about 29 V. Changes in harvester material can alter source impedance and the matching load, as demonstrated for ceramic-metal piezocomposites [29]. Rectifier diode leakage also affects low-power output [30].
The Norton source is a prescribed electrical benchmark. Mesh convergence of the electrical output and the 6.1% frequency discrepancy in Section 3.1 remain unresolved. Several control blocks are functional models whose internal protection behavior has not been validated. The initialized SECE cases include a modeled RESET-current peak of 30 mA, exceeding the supervisor’s ±10 mA absolute maximum [31]. The functional supervisor model uses idealized RESET transitions without a validated current limit. This does not justify the overcurrent: the RESET path must be corrected and revalidated before SECE operating points can be claimed to meet all component ratings. Hardware validation must address controller startup, protection currents, power consumption, magnetic losses, and thermal behavior. The effect of electrical loading on cantilever motion also requires verification.
4. Conclusions
A prescribed 50 Hz Norton source derived from a finite-element model was used to compare full-bridge, self-powered SECE, and self-powered P-SSHI interfaces. At 660 k, they deliver 227.9, 336.8, and 473.8 W, respectively. Both synchronized interfaces exceed the bridge output at every load where their operating points meet the comparison criteria. SECE gives the highest power at 100 and 350 k. P-SSHI leads from 600 k through 1.2 M among accepted reference points. The ranking change is bracketed by 350 and 600 k. These results apply to fixed reference component settings and do not locate an exact crossover. The bridge reaches 96% of its ideal maximum, whereas SECE reaches 34% of its ideal value, so the SECE result reflects the present self-powered implementation rather than the limit of the extraction principle. In the SECE winding-ratio study at 630 k, the 500 H and 1 mH series reach 307.3 and 371.9 W at . Power is still increasing there, so the optimum ratio remains unresolved, and the trend is obtained with fixed winding resistances. The 10 mH series has no accepted point. The 21-point SECE timing series give their highest tested powers at 330 pF for 100 k and at 300 pF for 200, 630, and 1000 k. The 330 pF reference is within 0.54% of each series’ largest sampled power. P-SSHI timing power at 630 k is highest at 200 pF, only 0.24% above the 150 pF reference. The accepted P-SSHI inductance maxima vary with load, with the 100 k result depending on the 2 mA current-lobe criterion. The common-load comparison gives the largest accepted P-SSHI power of 695.6 W at 1.2 M. At the next sampled load of 1.25 M, Q4 exceeds the selected 65 V limit while peak collector currents remain below 100 mA. The accepted P-SSHI range is therefore limited first by voltage stress. The larger numerical powers at higher loads cannot be treated as admissible output. SECE remains accepted under the comparison criteria through 1.8 M and exceeds the bridge output at the higher tested loads. The sampled transition does not establish an exact maximum permissible load. Separate component-study maxima are not substituted into the common-load comparison.
The study supports load-specific interface selection by considering settled power, switching behavior, and selected component limits together. Its contribution is a comparison of these established circuit implementations under a common prescribed source. Equal source parameters do not enforce equal electrical input power or account for feedback into cantilever motion. Mesh convergence of the electrical output and the modal-to-forced-response frequency discrepancy remain unresolved. Functional control models also limit hardware conclusions. In particular, the modeled SECE supervisor RESET-current peak reaches 30 mA against a ±10 mA absolute maximum. The reported operating points therefore require hardware validation of startup, controller protection currents, losses, and component stress.
Author Contributions
Conceptualization, E.K., V.M., D.N., D.A. and A.R.; methodology, E.K., A.V. and D.A.; software, E.B. and E.K.; validation, V.M., D.N., A.V., M.Ž. and A.R.; formal analysis, E.B., V.M. and D.N.; investigation, E.B. and E.K.; writing and original draft preparation, E.B.; writing, review and editing, A.V., M.Ž., D.A. and A.R.; visualization, E.K.; supervision, V.M., D.N. and A.R.
Funding
This project has received financial support from the Research Council of Lithuania (LMTLT) and the Ministry of Education, Science and Sport of the Republic of Lithuania, agreement No. S-A-UEI-23-1.
Data Availability Statement
The simulation data presented in this study are available on request from the corresponding author.
Conflicts of Interest
The authors declare no conflicts of interest.
Abbreviations
The following abbreviations are used in this manuscript:
| DC | Direct Current |
| FBR | Full-Bridge Rectifier |
| FEM | Finite-Element Method |
| IoT | Internet of Things |
| LC | Inductor–Capacitor |
| LDO | Low-Dropout Regulator |
| MOSFET | Metal–Oxide–Semiconductor Field-Effect Transistor |
| P-SSHI | Parallel Synchronized Switch Harvesting on Inductor |
| PVDF | Polyvinylidene Fluoride |
| RC | Resistor–Capacitor |
| SECE | Synchronous Electric Charge Extraction |
| SSHI | Synchronized Switch Harvesting on Inductor |
References
- Wang, F.; Zhou, M.; Wu, P.; Gao, L.; Chen, X.; Mu, X. Self-powered transformer intelligent wireless temperature monitoring system based on an ultra-low acceleration piezoelectric vibration energy harvester. Nano Energy 2023, 114, 108662. [Google Scholar] [CrossRef]
- Ravikumar, C. IoT Applications Powered by Piezoelectric Vibration Energy Harvesting Device. In Information and Software Technologies;Communications in Computer and Information Science; Lopata, A., Gudonienė, D., Butkienė, R., Eds.; Springer: Cham, Switzerland, 2022; Vol. 1665, pp. 171–182. [Google Scholar] [CrossRef]
- Liu, S.; Chen, S.; Gao, W.; Zhang, J.; Xu, D.; Chen, F.; Lu, Z.; Yu, X. A High-Efficiency Piezoelectric Energy Harvesting and Management Circuit Based on Full-Bridge Rectification. J. Low. Power Electron. Appl. 2024, 14. [Google Scholar] [CrossRef]
- Zhang, H.; Ma, T. Adaptive energy harvesting from low-level ambient vibrations. Appl. Mater. Today 2023, 34, 101911. [Google Scholar] [CrossRef]
- Zhao, B.; Qiu, J.; Liang, J. Circuit Solutions Toward Broadband Piezoelectric Energy Harvesting: An Impedance Analysis. IEEE Trans. Circuits Syst. I Regul. Pap. 2024, 71, 962–973. [Google Scholar] [CrossRef]
- Chen, K.; Zhuo, J.; Liu, W.; Huang, Y.; Hua, C.; Zhu, Q.; Yuan, Y. Self-sensed, self-adapted and self-powered piezoelectric generator architecture by synchronous circuits of autonomous parameter tuning. Energy Convers. Manag. 2024, 300, 117919. [Google Scholar] [CrossRef]
- Febbo, M.; Machado, S.P.; Oliva, A.; Ortiz, M.; Pereyra, N. Modelling of a piezoelectric beam with a full-bridge rectifier under arbitrary excitation: experimental validation. Energy Harvest. Syst. 2023, 10, 311–324. [Google Scholar] [CrossRef]
- Shen, J.; Xia, Y.; Xia, H. ReL-SSHI rectifier based piezoelectric energy harvesting circuit with MPPT control technique. Microelectron. J. 2022, 121, 105379. [Google Scholar] [CrossRef]
- Zhang, Z.; Tang, Z.; Zhang, Y.; Cheng, X.; Xie, G. A novel control circuit for piezoelectric energy harvesting. Microelectron. J. 2021, 113, 105068. [Google Scholar] [CrossRef]
- Khazaee, M.; Rezania, A.; Rosendahl, L. An experimental study to determine damping of piezoelectric harvesters using transient analysis of unified electromechanical voltage equation. Energy Convers. Manag. 2021, 227, 113567. [Google Scholar] [CrossRef]
- Zhang, Z.; Xiang, H.; Tang, L. Modeling, analysis and comparison of four charging interface circuits for piezoelectric energy harvesting. Mech. Syst. Signal Process. 2021, 152, 107476. [Google Scholar] [CrossRef]
- Qian, K.; Xia, H.; Xia, Y. A self-powered interface circuit for piezoelectric and photovoltaic energy extracting. Microelectron. J. 2024, 154, 106466. [Google Scholar] [CrossRef]
- Wu, L.; Zhu, P.; Xie, M. A Self-Powered Hybrid SSHI Circuit with a Wide Operation Range for Piezoelectric Energy Harvesting. Sensors 2021, 21. [Google Scholar] [CrossRef]
- Wang, J.; Xia, Y.; Shen, J.; Wang, X. Efficient self-powered piezoelectric energy harvesting interface circuit with wide rectified voltage. Microelectron. J. 2022, 126, 105474. [Google Scholar] [CrossRef]
- Lu, H.; Chen, K.; Tang, H.; Liu, W. Comparison of Four Electrical Interfacing Circuits in Frequency Up-Conversion Piezoelectric Energy Harvesting. Micromachines 2022, 13. [Google Scholar] [CrossRef]
- Yang, L.; Wei, T.; Chen, N.; Wang, Y.; Shi, X. Analysis and comparison of three energy harvesting circuits for impact-type piezoelectric energy harvester. Smart Mater. Struct. 2024, 33, 125036. [Google Scholar] [CrossRef]
- Xia, H.; Xia, Y.; Shi, G.; Ye, Y.; Wang, X.; Chen, Z.; Jiang, Q. A Self-Powered S-SSHI and SECE Hybrid Rectifier for PE Energy Harvesters: Analysis and Experiment. IEEE Trans. Power Electron. 2021, 36, 1680–1692. [Google Scholar] [CrossRef]
- Lo, Y.; Shu, Y. Self-powered SECE piezoelectric energy harvesting induced by shock excitations for sensor supply. Mech. Syst. Signal Process. 2022, 177, 109123. [Google Scholar] [CrossRef]
- Ravikumar, C.; Markevičius, V.; Navikas, D.; Čepėnas, M.; Valinevičius, A.; Žilys, M.; Šotner, R.; Jerabek, J.; Li, Z.; Včelák, J.; et al. Temperature Effect Analysis of PVDF-Based Piezoelectric Energy Harvester. IEEE Sens. J. 2025, 25, 42881–42894. [Google Scholar] [CrossRef]
- Mohd Fairuz, W.N.; Mohd Nawi, I.; Ahmad, M.R.; Kannan, R. Experiment and performance analysis of serpentine-shaped cantilever beam for pipeline vibration-based piezoelectric energy harvester prototype development. Clean Energy 2024, 8, 111–134. [Google Scholar] [CrossRef]
- Ravikumar, C.; Markevicius, V. Ferroelectret Polypropylene Foam-Based Piezoelectric Energy Harvester for Different Seismic Mass Conditions. Actuators 2023, 12. [Google Scholar] [CrossRef]
- Pandiev, I.; Antchev, H.; Kurtev, N.; Tomchev, N.; Aleksandrova, M. Analysis and Design of Low-Power Piezoelectric Energy Harvesting Circuit for Wearable Battery-Free Power Supply Devices. Electronics 2025, 14. [Google Scholar] [CrossRef]
- Lefeuvre, E.; Badel, A.; Richard, C.; Guyomar, D. Piezoelectric Energy Harvesting Device Optimization by Synchronous Electric Charge Extraction. J. Intell. Mater. Syst. Struct. 2005, 16, 865–876. [Google Scholar] [CrossRef]
- Liu, H.; Hua, R.; Lu, Y.; Wang, Y.; Salman, E.; Liang, J. Boosting the efficiency of a footstep piezoelectric-stack energy harvester using the synchronized switch technology. J. Intell. Mater. Syst. Struct. 2019, 30, 813–822. [Google Scholar] [CrossRef]
- Qiu, J.; Liang, J. A Self-Powered Extensible SECE Rectifier for Piezoelectric Energy Harvesting. In Proceedings of the 2022 International Power Electronics Conference (IPEC-Himeji 2022—ECCE Asia), Himeji, Japan, 15–19 May 2022; pp. 1–5. [Google Scholar] [CrossRef]
- Ben Ammar, M.; Sahnoun, S.; Fakhfakh, A.; Viehweger, C.; Kanoun, O. Self-Powered Synchronized Switching Interface Circuit for Piezoelectric Footstep Energy Harvesting. Sensors 2023, 23. [Google Scholar] [CrossRef]
- Younas, O.; Li, P.; Wen, Y. An efficient self-powered piezoelectric energy extraction scheme with cascaded-gyrators-based transformer. Microelectron. J. 2024, 149, 106254. [Google Scholar] [CrossRef]
- Khan, S.; Kumrawat, A.; Mukherjee, B. Performance Improvement of a Self-powered P-SSHI based Piezoelectric Energy Harvester by Tuning the Switching Delay and Inversion Factor. Sustain. Energy Technol. Assess. 2025, 75, 104240. [Google Scholar] [CrossRef]
- Zhao, K.; Zheng, M.; Yan, X.; Zhu, M.; Hou, Y. Tailored Ceramic–Metal Piezocomposite Energy Harvester with High Current Output by Controlling the Electrical Impedance. ACS Appl. Electron. Mater. 2022, 4, 3679–3685. [Google Scholar] [CrossRef]
- Nadaud, K.; Poulin-Vittrant, G.; Alquier, D. Influence of topology and diode characteristics of AC-DC converters for low power piezoelectric energy harvesting. Sens. Actuators A Phys. 2021, 330, 112901. [Google Scholar] [CrossRef]
- Texas Instruments. TPS383x 150-nA, Ultralow Power, Supply Voltage Monitor. Datasheet SBVS193D, Rev. D, 2015. Available online: https://www.ti.com/lit/ds/symlink/tps3839.pdf (accessed on 14 October 2026).
Table 1.
Main geometrical and operating parameters of the piezoelectric harvester.
| Parameter | Symbol | Value |
|---|---|---|
| Cantilever length | 18.3 mm | |
| Cantilever width (out-of-plane thickness) | W | 68 mm |
| PVDF-layer thickness | 30 m | |
| Steel-substrate thickness | 0.1 mm | |
| Proof mass | 8.5 g | |
| Nominal excitation frequency | f | 50 Hz |
| FEM-derived nominal reference load | 660 k | |
| Base-excitation acceleration amplitude | 0.5 g |
Table 2.
Electrical parameters of the Norton equivalent model derived from the COMSOL FEM response.
| Parameter | Symbol | Value |
|---|---|---|
| Norton current-source peak amplitude | 48.77 A | |
| Piezoelectric capacitance | 4.83 nF | |
| Equivalent parallel resistance | 27.5 M | |
| Near-open-circuit peak voltage | 32.14 V | |
| Source-impedance magnitude at 50 Hz | 659 k |
Table 3.
Reference settings and investigated quantities. Some controller blocks use functional models. Terminal checks cover selected device limits.
Table 3.
Reference settings and investigated quantities. Some controller blocks use functional models. Terminal checks cover selected device limits.
| Interface | Reference Parameters | Investigated Quantities |
|---|---|---|
| Schottky full bridge | DFLS2100, F | Load resistance |
| SECE | mH, , , pF, ZVN4424A, BAS21H, harvested 3 V controller | Load resistance, transformer winding ratio at three primary inductances, timing capacitance at four loads |
| P-SSHI | H, pF, BC856B/BC546B, DFLS2100, 100 k detector isolation | Load resistance, timing capacitance, inversion inductance at four loads |
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.
Copyright: This open access article is published under a Creative Commons CC BY 4.0 license, which permit the free download, distribution, and reuse, provided that the author and preprint are cited in any reuse.