Submitted:
18 November 2026
Posted:
19 November 2026
You are already at the latest version
Abstract
Human–robot interaction (HRI) evaluation increasingly combines questionnaires, performance measures, qualitative data, and physiological sensing, yet multimodality alone may leave relevant experiential distinctions unresolved. We revisit a with-in-subject XR robot-programming study (N = 21) in which 16 participants preferred full-speed (XR-1×) over one-fifth-speed (XR-0.2×) replay, despite exploratory equiva-lence on selected questionnaire and performance outcomes. Using convergent mixed methods, we integrated previously unreported electrodermal activity (EDA) and elec-trocardiogram (ECG) analyses with systematic content analysis of participants' ex-planations at group and individual levels. Phasic EDA was lower in XR-0.2× in nearly every participant; an apparent RMSSD difference did not survive correction for multi-ple comparisons. Ten participants described slower replay as a cost, including four who mentioned boredom, whereas four of the five preferring XR-0.2× cited perceived benefits related to safety, reliability, accuracy, or control. Physiological differentiation was broadly consistent across participants, whereas their evaluations diverged, un-derscoring the distinct evidential roles of physiological and qualitative data. Method-ologically, these findings show how testing equivalence, incorporating open-ended questions, and integrating physiology with open-ended responses can help resolve ap-parent-equivalence cases in HRI evaluation; for interaction design, they highlight replay speed as a consequential design parameter whose expe-riential implications extend beyond execution time.

Keywords:
human–robot interaction
; multimodal evaluation
; mixed methods
; open-ended responses
; electrodermal activity
; wearable sensing
; extended reality
; robot programming
; user experience
1. Introduction
Industrial human–robot interaction (HRI) is increasingly evaluated not only in terms of productivity, accuracy, and technical reliability, but also according to how robotic systems are experienced by the people who interact with them [1,2]. Human-centred outcomes such as workload, usability, trust, perceived safety, and technology acceptance can directly affect whether a technically successful robotic solution can be adopted and sustained in practice [3]. This is particularly relevant as collaborative robots move from fenced automation toward shared workspaces and closer temporal coordination with human operators [4]. In parallel, extended reality (XR) interfaces are emerging as practical tools for robot programming, offering spatially grounded visualization and direct-in-space interaction that can reduce programming barriers and support more intuitive interaction with robotic systems [5,6]. These developments increase the need for evaluation approaches capable of identifying meaningful differences between interaction designs, including differences that may not be reflected in conventional performance indicators alone [7].
HRI evaluation has consequently become increasingly multimodal. Task performance is commonly complemented with standardized questionnaires, behavioral observations, qualitative data, and, more recently, physiological sensing [8]. This broader evaluation landscape is important because each measurement approach captures a different aspect of the interaction [9,10]. Nevertheless, multimodality does not necessarily imply comprehensive coverage of the user experience. Most evaluation instruments remain organized around constructs selected before data collection. Standardized questionnaires provide reliable and comparable measures of anticipated dimensions such as workload, usability, trust, or perceived safety, while physiological measures are also frequently selected and interpreted in relation to predefined constructs such as workload or stress. Recent reviews of HRI evaluation therefore show a relatively stable concentration around a limited set of human factors, despite the increasing diversity of measurement techniques [11,12,13].
This creates an important boundary for human-centred evaluation. A questionnaire can establish that two interaction conditions are similar with respect to the constructs it measures, but this does not necessarily imply that the overall interaction experiences are equivalent. Design differences may affect qualities that were not anticipated when the evaluation protocol was defined, such as waiting, pacing, monotony, responsiveness, or temporal correspondence between human actions and robot behavior. Including a questionnaire for every possible experiential dimension is neither realistic nor methodologically desirable. Instead, situations in which predefined measures indicate equivalence may benefit from additional forms of evidence that are sensitive to differences outside those predefined constructs.
Physiological sensing provides one such source of evidence. Measures such as electrodermal activity (EDA) and heart-rate variability (HRV) can record autonomic responses continuously during interaction and may therefore differentiate conditions even when retrospective questionnaire ratings remain similar [11,14,15]. However, physiological differentiation is not self-explanatory: variation in sympathetic or cardiac activity does not uniquely identify a specific psychological state [16]. Physiological evidence can therefore establish that interaction conditions were associated with different bodily responses, but additional contextual evidence is needed to understand what those differences may have meant to participants. Open-ended responses provide this complementary perspective: Interviews, open-ended questions, and free-text comments allow users to introduce experiential qualities and interpretations that were not specified by the researcher beforehand [17]. Conversely, comments alone cannot show whether a difference also affected participants who did not mention it, or whether participants who valued a design differently had responded differently or had interpreted the same response differently [18]. The reasons people give for a choice may also be constructed after the choice is made [19,20]. Mixed-method HRI studies further show that open-eded questions and physiological measures can contribute different information about the same interaction [21]. Their value therefore lies not in treating one source as ground truth for the other, but in examining what each contributes to the interpretation of the interaction.
The present paper builds on the within-subject XR robot-programming experiment previously reported by Escallada et al. [22], in which two XR modes shared the same interface and procedure but differed in the speed at which the physical robot replayed the programmed trajectory: full speed (XR-1×) and one-fifth speed (XR-0.2×). The two modes did not differ significantly on the reported questionnaire items, yet 16 of 21 participants ranked XR-1× above XR-0.2×. The earlier study observed this divergence but did not explain it. The present exploratory secondary analysis revisits it by combining equivalence tests on the questionnaire and performance data, previously unreported EDA and ECG recordings, and a systematic analysis of participants’ open-ended responses, integrated at group and participant levels. Rather than treating physiology as an objective explanation of preference, it examines what each evaluation channel contributes and where its interpretation is limited.
Accordingly, the study addresses two research questions, with the second divided into two complementary subquestions:
RQ1. Do physiological measures differentiate between two XR robot-programming modes that show bounded equivalence on selected predefined measures?
RQ2. How do participants’ open-ended responses help contextualize the physiological differentiation and the divergence in preference between the two XR modes?
- RQ2a. How do participants’ descriptions of their experiences with replay speed help contextualize the observed physiological differentiation between the two XR modes?
- RQ2b. What reasons do participants provide for preferring one XR mode over the other, and how do these open-ended responses help explain the divergence in preference?
The paper makes two contributions. The first is methodological: it shows how to read an apparent-equivalence case, in which predefined measures show no difference, but preference diverges. Equivalence is tested rather than assumed; concurrent physiology shows whether, and in whom, the conditions differed; participants’ comments show what the difference meant; and the channels are integrated at the group and participant levels, where the silence of a measure can be told apart from discordance. The case also shows why physiology and comments are both needed, because the same bodily change was valued in opposite ways. The second contribution is practical: For interaction design, it identifies replay speed in XR robot programming as an experience-relevant parameter whose effects extend beyond execution time and beyond the constructs usually measured.
2. Materials and Methods
2.1. Multimodal HRI Evaluation: Methodological and Construct Coverage
To contextualize current human-factor evaluation practices in HRI, we examined eight recent reviews published between 2022 and 2025 covering collaborative and physical HRI [1,2,3,8,13,23,24,25]. Table 1 summarizes the human factors and evaluation methods reported across these reviews. Because the reviews differ in scope and partly overlap in the primary studies they include, the synthesis is descriptive and is used to identify recurring review-level patterns rather than to estimate the prevalence of particular constructs or methods across the broader HRI literature.
Two observations are particularly relevant to the present study. First, although multimodal evaluation is clearly established in HRI, the different modalities are not represented equally. Questionnaires were the most consistently visible instrument and, where primary-study counts were available, were used in a substantial proportion of the reviewed studies. For example, Hopko et al. reported questionnaires in 42 of 61 studies, Nobile et al. in 62 of 76, Liu et al. in 33 of 46, and Yahia et al. in all 15 studies included in their review [2,23,24,25].
Physiological sensing was represented across the eight reviews, although its use was less dense and varied considerably by review and application. The reported measures included electrodermal activity, electrocardiography and heart-rate variability, electroencephalography, muscular activity, skin temperature, and other wearable signals. This reflects increasing interest in obtaining concurrent and nonverbal evidence of human responses during interaction. Reviews of quantitative and physiological assessment commonly positioned these signals in relation to established human-factor constructs such as workload, stress, fatigue, or trust [8,11,13,24]. Physiological sensing therefore broadens the temporal and observational basis of HRI evaluation, but it does not necessarily broaden its conceptual scope when physiological features are selected primarily to investigate constructs already defined in advance.
Participant-generated comments had substantially less visibility in review-level reporting. Interviews or think-aloud protocols were explicitly reported in only two of the eight reviews. Hopko et al., for example, identified interviews in 7 and think-aloud methods in 2 of 61 primary studies, while Liu et al. identified interviews in 3 of 46 studies [2,25]. This does not demonstrate that open-ended approaches are absent from the wider primary literature, since reviews may exclude them, classify them inconsistently, or omit them from their summaries. It does, however, reveal an asymmetry in the types of evidence that are visible at review level: HRI evaluation is multimodal, but much of that evidence remains structured around measures whose content and interpretation are defined by researchers before data collection.
A second pattern concerns what HRI studies evaluate. Across the eight reviews, cognitive workload, trust, and stress recur prominently, commonly alongside usability, perceived safety, physical comfort, fatigue, technology acceptance, and general emotional responses. These constructs reflect central concerns in industrial and collaborative HRI, particularly regarding safe, usable, and acceptable deployment. Their recurrent use also means that evaluations are frequently structured around a relatively stable set of dimensions defined before the interaction takes place. Experiences that differ along dimensions not represented in the selected instruments may therefore remain unresolved by those measures.
Standardized instruments such as the NASA Task Load Index and the System Usability Scale provide validated and comparable assessments of predefined constructs such as workload and usability [26,27]. Physiological sensing can complement these measures with concurrent evidence of autonomic activity [11,14]. However, adding measurement modalities does not necessarily broaden the conceptual coverage of an evaluation when both questionnaire items and physiological features are selected primarily to investigate constructs specified in advance.
This boundary is inherent to experimental design rather than a limitation of any particular instrument. Researchers must select constructs according to the aims of the study, prior evidence, and anticipated human-factor concerns; no protocol can measure every experiential quality that may become relevant during interaction. Similar scores on workload, usability, trust, or perceived safety should therefore be interpreted as bounded equivalence on those measured constructs, rather than as evidence that the overall experiences were identical. Other differences may emerge along temporal, affective, or interaction-specific dimensions that were not represented in the original protocol.
Previous HRI studies illustrate this type of cross-channel divergence. Zhang et al. found that gaze-based measures captured temporal variation in dynamic trust that was not equally reflected in standardized self-report, highlighting differences in the sensitivity of evaluation channels to evolving interaction states [10]. Similarly, Prajod et al. reported that physiological and affective measures provided information about perceived challenge in collaborative HRI that was not fully represented by NASA-TLX ratings [28]. Such findings suggest that apparent similarity on standardized scales can coexist with differences captured through other forms of evidence.
Identifying that a difference exists, however, does not necessarily reveal what that difference meant to the participant. Participant-led methods such as interviews, open-ended questions, and free-text explanations provide a complementary route by allowing users to introduce qualities, interpretations, and trade-offs that were not predefined by the researcher [17]. These comments remain retrospective and selective and therefore require systematic and transparent analysis [29], but they can reveal what participants themselves noticed, valued, or disliked about an interaction. Related mixed-method HRI work illustrates this complementary role. Lawrence et al. combined standardized questionnaires with physiological responses, behavioral observations, and participant-generated responses, with the different channels contributing additional information to the interpretation of robot norm violations [21].
Physiological and participant-generated data therefore serve different but complementary evidential roles. Physiological sensing can establish that interaction conditions were associated with different concurrent autonomic responses, but it does not uniquely determine their psychological meaning [30]. Open-ended questions can identify experiential meanings and unanticipated trade-offs, but they do not independently establish whether those experiences were accompanied by systematic physiological differentiation. Their value lies in integration: determining where data streams converge, where they diverge, and what each source contributes to the interpretation of the interaction. This distinction becomes particularly important when predefined questionnaire measures indicate similarity between conditions. In such cases, physiological sensing can test whether that apparent equivalence also extends to concurrent autonomic response, while participant-generated comments can identify experiential distinctions that were not specified in the original measurement protocol. Recent multimodal evaluation approaches similarly treat the integration of physiological, behavioral, contextual, and self-reported evidence as a methodological task in its own right [31].
The relevant gap is therefore not the absence of multimodal HRI evaluation, nor the absence of studies combining qualitative and physiological data. Rather, comparatively little attention has been given to how concurrent physiological differentiation and participant-generated meaning can be integrated when standardized measures indicate bounded equivalence while preference or other comparative judgments diverge.
2.2. Human-Factor Evaluation and Temporal Interaction in XR Robot Programming
XR technologies are increasingly used to support robot programming, teleoperation, visualization, and collaboration by embedding virtual trajectories, robot states, and task information within the interaction workspace [5,6,32,33]. These interfaces introduce not only new interaction possibilities but also additional challenges for human-factor evaluation. A recent review of industrial VR identified 29 human factors and 240 different measurement approaches across 24 studies, highlighting both the breadth of constructs considered relevant and the absence of a standardized methodology for evaluating human experience in industrial VR [34]. Usability, workload, ergonomics, learnability, and broader user-experience constructs were among the factors most frequently assessed, while terminology, metrics, and data-collection approaches varied considerably across studies. The review further cautioned that standardized instruments developed in other domains may not transfer appropriately to VR contexts without validation for the technology [34].
This heterogeneity does not imply that established HRI measures such as workload, usability, trust, or perceived safety are unsuitable for XR-mediated interaction. These constructs remain relevant to the safe and usable deployment of robotic systems. Rather, it reinforces the broader construct-coverage issue discussed in Section 2.1: in a technological context for which there is no agreed set of human factors or evaluation protocol, a predefined questionnaire battery can provide strong evidence about the constructs it contains without necessarily exhausting the experiential dimensions that become relevant during interaction [34]. Complementary evaluation channels may therefore be particularly useful in XR studies, where spatial, perceptual, and temporal properties of the interface can introduce qualities that were not anticipated when the original evaluation protocol was defined.
One such property is the temporal relationship between user action and system response. Communication delay can increase perceived workload and degrade teleoperation performance [35] while predictive and enhanced interfaces have been developed to mitigate the effects of substantial delay [36,37]. In virtual and augmented environments more broadly, lag, frame rate, and system latency can also affect interaction performance and the validity of the simulated experience [38]. Robot speed represents a related but distinct temporal design variable: speed and acceleration can influence human-factor outcomes during collaborative interaction [39]. Rakita et al. further distinguished uniformly slowed robot motion from latency before motion onset, showing that users respond differently to these forms of temporal manipulation [40]. More generally, anticipatory timing and synchronization between human and robot actions have been associated with perceived teamwork fluency and trust [41,42].
These findings position replay speed as a meaningful interaction property rather than a purely technical parameter. At the same time, the literature does not prescribe a single human-factor construct through which its experiential consequences should be evaluated. The effects of slower replay may depend on the interaction context and may overlap only partially with broader constructs such as workload, usability, trust, flow, or agency. Replay speed therefore provides a useful case for examining what additional information can emerge when predefined measures are complemented by evaluation channels that do not require the relevant experiential distinction to be specified in advance.
The present study examines such a case in XR robot programming. In both XR conditions, participants used the same interface and programming procedure; the conditions differed only in the speed at which the physical robot subsequently replayed the demonstrated trajectory. The original evaluation already included a broad set of human-factor measures, including workload, usability, flow, agency, and trust [22]. The present secondary analysis examines what additional information physiological differentiation and participant-generated comments can provide when this predefined battery does not distinguish two interaction modes that users nevertheless evaluate differently.
3. Materials and Methods
3.1. Study Dataset and Relationship to the Previous Report
The present study is an exploratory secondary analysis of the dataset collected in the XR robot-programming experiment previously reported by Escallada et al. [22]. It uses the same 21 participants and experimental sessions; no additional participants were recruited, and no new data were collected. The earlier publication compared kinesthetic teaching with two XR-based programming modes and presented item-level questionnaire analyses, task performance measures, preference rankings, and a brief descriptive summary of participants’ open-ended comments. EDA and ECG were recorded in the same sessions but were not analyzed in [22]. That report, a pilot study led by another author, addressed self-report and task performance; the physiological recordings required separate processing, including synchronization with the event logs and video, which was not complete when it was prepared. The earlier report mentioned biometric analysis only as future work, without stating that the signals had already been recorded.
The present paper extends this earlier work through four analytical components. First, existing questionnaire and performance data are reanalyzed using construct-level scores and exploratory equivalence tests (TOST) to assess similarity between the two XR modes on selected predefined outcomes. Second, the electrodermal activity (EDA) and electrocardiogram (ECG) recordings collected during the original sessions, but not analyzed in the previous publication, are examined. Third, the complete set of participants’ open-ended ranking explanations is subjected to systematic content analysis, extending the brief descriptive reporting in the earlier study. Finally, these evaluation channels are explicitly integrated at group and participant levels to examine what each contributes to understanding the physiological differentiation and the divergence in participants’ preferences. Previously published questionnaire, performance, and ranking findings are retained as context for the new analyses and are not presented as new experimental observations.
The analysis followed a convergent mixed-methods design [43]: the evaluation channels were collected in the same sessions, analyzed separately, and then merged. It proceeded in three stages followed by integration (Figure 1). Stage 1 tested whether the two XR modes were equivalent on the predefined measures while preference diverged (Section 3.6.1). Stage 2 tested whether concurrent physiological measures nevertheless differentiated the two modes (RQ1; Section 3.6.2). Stage 3 analyzed how participants themselves described the difference (RQ2; Section 3.6.3). The results of all channels were then integrated at the group level and at the participant level (Section 3.7). Physiological data had priority for establishing whether the two modes differed, and participants’ comments for interpreting what the difference meant; neither was treated as ground truth for the other. Reporting was guided by the Good Reporting of A Mixed Methods Study (GRAMMS) guidance [44]; Table S1 shows where each item is addressed. All analyses were exploratory and were not preregistered.
3.2. Participants
Twenty-one volunteers (11 female, 10 male; Mage=22.76, SDage=4.28) were recruited. Inclusion criteria required normal or corrected-to-normal vision and no self-reported dermatological, cardiovascular, or neurological conditions likely to affect EDA or HRV. Participants provided written informed consent. The study protocol was approved by the Research Ethics Committee of the author’s institution (approval number IEB-2024-1118) and by the Ethics Committee of Boğaziçi University (approval number E-84391427-050.04-211747). A sensitivity analysis indicated that with N=21 we had 80% power to detect within-subject effects of approximately dz≈0.65 (two-tailed, α=0.05). All 21 participants were included in the questionnaire, performance, preference ranking, and qualitative analyses. Physiological data from one participant were excluded because of insufficient signal quality, resulting in a sample of 20 participants for the EDA and ECG analyses.
3.3. Materials
Participants programmed a UR10 collaborative robot arm (Universal Robots, Odense, Denmark) over a 160 × 75 cm table carrying printed trajectories, lightweight obstacles, and target objects (Figure 2). XR programming used a Meta Quest 3 head-mounted display (Meta Platforms, Menlo Park, CA, USA) running RAMPA [6],with which the user draws a trajectory above the table using hand tracking while a virtual robot follows the drawn path in the passthrough view. The interaction software and robot controller logged event timestamps (programming onset and offset, replay onset and offset, and trial boundaries) and robot state; these were cross-checked against video recordings to synchronize behavioral and physiological data.
EDA and ECG were recorded with a Bitbrain Versatile Bio amplifier (Bitbrain, Zaragoza, Spain) at 256 Hz with 24-bit resolution and streamed wirelessly to the acquisition computer (Figure 3). EDA electrodes were placed on the index and middle fingers of the non-dominant hand. ECG was recorded with three surface electrodes: two placed subclavicularly (left and right clavicles) and one placed below the right breast over the rib cage. Electrode placement and skin preparation followed standard procedures, and participants could pause or stop the session at any time. Signals were acquired with the Bitbrain software and processed with custom Python scripts, archived with the raw data (see Data Availability Statement).
3.4. Task and Procedure
Participants completed three path-programming tasks of increasing difficulty: planar tracing (T1), planar tracing with obstacles (T2), and three-dimensional tracing ending in an interaction with an object (T3); full descriptions are given in [19]. Errors were deviations from the target corridor or contacts with obstacles, verified from experimenter logs and video. Each task was performed in three modes, giving nine trials per participant: kinesthetic teaching (KT), in which participants guided the robot arm by hand; XR programming with RAMPA and replay at the drawn speed (XR-1×); and the same XR programming with replay at one-fifth of that speed (XR-0.2×). KT was kept as a reference; the comparison of interest is between the two XR modes, which differed only in replay speed and hence in how long participants watched the physical robot. Mode order was counterbalanced with a Latin square, and tasks followed the order T1–T3. Participants completed the questionnaire after each mode and ranked the modes, with an explanation, at the end of the session.
3.5. Evaluation Channels
The study recorded five evaluation channels: a predefined questionnaire after each block, performance logs during the trials, a preference ranking and a free-text explanation at the end of the session, and EDA and ECG throughout.
- Retrospective questionnaires: After each mode block, participants rated 21 items on a 21-point scale: six items from the System Usability Scale (usability; Cronbach’s α = 0.81) [27], six NASA Task Load Index items (workload; α = 0.74) [26], four Flow State Scale items (α = 0.32) [45], two Sense of Agency Scale items (α = 0.73) [46], and three items from a trust scale for industrial human–robot collaboration (α = 0.58) [47].
- Performance: Completion time per task included programming and replay, so it reflects the slower replay directly. Attempts (reprogramming before success) and errors (deviations from the circuit or contacts with obstacles) were counted from logs and video [22]. In the earlier report, most errors in the XR modes were attributed to calibration offsets and loss of hand tracking rather than to participants’ actions [22].
- Comparative Judgment: Preference Ranking: At the end of the session, participants were asked to “classify from 1 (most suitable) to 3 (less suitable) the 3 ways you interacted with the robot and explain why” [22]. We refer to the ranking as a preference ranking.
- Open-ended responses: The second part of the same prompt asked participants to explain their ranking. Each participant wrote a single answer in English, with no further prompts; answers ranged from 16 to 73 words (median 45). We refer to these explanations as open-ended responses or comments. Because they were written once, at the end of the session, to justify a ranking of suitability, they capture what participants chose to mention about each mode as a whole, not experiences tied to individual trials. English was not the first language of most participants.
- Physiological Signals: EDA and ECG were recorded continuously throughout the session. A five-minute resting baseline was also recorded but was excluded from the analyses because of inconsistencies across participants and sessions. Consequently, no resting-baseline correction was applied to the physiological features. Instead, the features were standardized within participants across the nine experimental trials, as described in Section 3.6.2.
3.6. Data Analysis
3.6.1. Stage 1: Bounded Equivalence and Divergent Preference
Stage 1 reanalyzed the questionnaire, performance, and ranking data of the original experiment [22]. Items were averaged into construct scores, oriented so that higher values were more favorable. Mode effects on usability, workload, agency, attempts, errors, and completion time were tested with repeated-measures ANOVAs (η2p) and Holm-adjusted pairwise comparisons; flow and trust were excluded for equivalence testing for low internal consistency (α = 0.32 and 0.58). Equivalence between XR-1× and XR-0.2× was tested for usability, workload, agency, attempts, and errors with two one-sided tests [48], with bounds of ±0.5 dz: equivalence held when the 90% confidence interval fell within the bounds, and outcomes that missed this criterion were called inconclusive. With no established minimal important difference, the bound was set at a medium effect [49], close to the smallest effect the sample could detect (Section 3.2); equivalence therefore excludes only medium or larger differences, and only on the measured constructs. Completion time, which included the replay, was treated as a manipulation check. Rankings were analyzed with the Friedman test (Kendall’s W) and, for XR-1× versus XR-0.2×, a two-sided exact sign test with an exact 95% confidence interval. Analyses used Python (α = 0.05).
3.6.2. Stage 2: Physiological Differentiation (RQ1)
Stage 2 tested whether concurrent physiology differentiated the two XR modes. The features were chosen to suit single trials lasting from under one minute to about three minutes. For EDA, the analysis focused on phasic features, which respond within seconds to sympathetic activation: SCR rate (peaks per minute), SCR amplitude (mean phasic value at detected peaks), and phasic area per minute (the integral of the absolute phasic signal divided by trial duration). Mean skin conductance level (SCL) and SCL slope (linear trend) were included as slower, tonic complements [15,50]. Rate and area were expressed per minute so that trials of different lengths could be compared. For the ECG, only time-domain HRV was used: RMSSD served as the main index because it reflects vagally mediated variability and can be estimated from short recordings, and SDNN was included as an index of overall variability [51,52]. Frequency-domain and nonlinear indices were not computed, because they require longer stationary recordings than most trials provided [51]; HRV estimates from trials shorter than one minute are less reliable, and HRV results are interpreted with caution.
EDA was low-pass filtered (2 Hz, second-order zero-phase Butterworth). The tonic component was estimated with a centered 5 s moving average, chosen to separate responses lasting a few seconds from slower drifts, and the phasic component was taken as the residual [15]. SCRs were detected as peaks in the phasic signal whose prominence exceeded 0.05 times the standard deviation of that trial’s phasic signal. This threshold is relative to each trial’s variability rather than an absolute amplitude in microsiemens, as in conventional criteria [15,50]; in trials with little phasic variability it admits smaller peaks, which works against finding fewer SCRs in such trials. Phasic area does not depend on any detection threshold and was therefore analyzed alongside SCR rate. The ECG was band-pass filtered, R-peaks were detected with a custom routine, and SDNN, RMSSD, and the coefficient of variation (CV = SDNN / mean inter-beat interval) were computed from the inter-beat intervals.
Features were computed over the whole trial, from programming onset to the end of the replay. Whole-trial windows therefore differ in composition: watching made up about 20% of an XR-1× trial and 56% of an XR-0.2× trial (estimated from mean completion times), and programming and watching were not analyzed separately. Skewed features were log-transformed, and each feature was standardized within participant across the nine trials with robust z scores (median and MAD) and averaged across tasks, giving one value per participant and mode; CV was dropped because of extreme standardized values. Mode effects (n = 20) were tested with repeated-measures ANOVAs and Holm-corrected paired comparisons, with the seven omnibus p values also Holm-adjusted across features. A feature differentiated the XR modes when it survived this adjustment and its XR-1× versus XR-0.2× contrast was significant, and was reported as a trend when only the contrast was significant. For differentiating features, we counted the participants showing the same direction. Processing scripts and parameters are available at Zenodo (https://doi.org/10.5281/zenodo.19349295; see Data Availability Statement).
3.6.3. Stage 3: Content Analysis of Open-Ended Responses (RQ2a–RQ2b)
The open-ended responses or comments were analyzed with conventional content analysis, in which codes are derived from the data rather than from a predefined framework [Hsieh 2005]. The unit of analysis was the participant’s comment. Codes were developed inductively through repeated reading of all comments and grouped by what they referred to: replay speed (the difference between the two XR modes), XR programming in general, and kinesthetic teaching. Each code was given a definition and an example quotation, which together form the codebook (Table 8). Each comment was coded for every code it contained, so one comment could carry several codes; a comparative statement, such as that one replay was more accurate than the other, was coded once.
The codebook was developed by [N.O.]. A second coder [A.A.] then coded all comments independently with the codebook, in a randomized order, with participant identifiers removed and without access to the first coding or the physiological results. Agreement before discussion was high (pooled Cohen’s κ = 0.93 across 12 codes and 21 comments, 97% agreement; per-code κ 0.74–1.00), and the seven disagreements were resolved by discussion. Because the comments explained the rankings, the coders could not be blind to participants’ preferences. For each code, we report the number of participants whose comment contained it, separately for participants who ranked XR-1× above XR-0.2× and for those who ranked it below. Counts describe what participants chose to mention, not how strongly they felt it, so no inferential tests were applied to them; in addition, the comments explained the rankings and are not independent of them. All comments with their codes are given in Appendix A. Quotations are reproduced verbatim except for corrected spelling and typing errors; identifiers give a participant number and gender (F, female; M, male).
3.7. Integration Across Evaluation Channels
Integration was organized by research question and by level of analysis, both set by the design rather than by the results (Figure 1). At the group level, the channels were brought together in a joint display [43] (Table 8), with one row per research question. Each cell summarizes what one channel showed in Stages 1–3 and records its stance: yes (it registered the difference or quality in question), no (it addressed it without registering a difference), inconclusive, or silent (it did not address it). For each question, the relations between channels were classified as confirmation, expansion, or discordance, or as silence when a channel did not address a quality revealed by another [43,44]; discordance thus means pointing the other way, silence not addressing the quality at all. Two researchers carried out the integration together (N.O. and A.A.) [44], and all authors discussed the results.
At the participant level, a mixed-methods matrix [44] (Table A1) listed each participant’s ranking, comment and codes, and XR-1× minus XR-0.2× differences on usability, workload, agency, SCR rate, and phasic area (Figure 8). It was read by the same questions: whether the contrasts held for individuals (RQ1), whether the physiological contrast differed between participants who described the slow pace as a cost and those who did not mention it (RQ2a), and how participants who preferred each mode differed (RQ2b). The matrix was read descriptively; no statistical association was tested, because comments were collected once per session and only five participants, four with physiological data, preferred XR-0.2×.
4. Results
The results follow the order of the analysis (Figure 1): the premise established on the predefined measures and the preference ranking (Section 4.1), the physiological comparison (Section 4.2; RQ1), the participants’ comments (Section 4.3; RQ2), and the integration of all channels at the group and participant levels, which completes the answers to both research questions (Section 4.4).
4.1. Stage 1: Equivalent on the Predefined Measures, Divergent in Preference
Completion time differed between modes (F(2,40) = 66.82, p < 0.001, η2p = 0.77): XR-0.2× trials took 81% longer than XR-1× trials, with KT in between (Table 2, panel C), which confirmed the manipulation.
Mode affected usability (F(2,40) = 17.52, η2p = 0.47), workload (F(2,40) = 15.77, η2p = 0.44), attempts (F(2,40) = 14.23, η2p = 0.42), and errors (F(2,40) = 11.79, η2p = 0.37; all p < 0.001), but not flow, agency, or trust (all p ≥ 0.28, η2p ≤ 0.06). All four effects reflected differences between KT and the XR modes (Holm-corrected ps ≤ 0.002): both XR modes were rated more usable (dz = 0.91 and 0.96) and less demanding (dz = 1.01 and 0.87) than KT, but required more attempts and produced more errors, as in the earlier report [22], which attributed most XR errors to calibration offsets and loss of hand tracking.
Between the two XR modes, usability, workload, and attempts were equivalent within ±0.5 dz, whereas agency (equivalence p = 0.053) and errors (p = 0.111) were inconclusive: their differences were small, but their confidence intervals reached the bound (Table 2, panel A). Rankings differed between modes (Friedman χ2(2) = 16.10, p < 0.001, W = 0.38): XR-1× was ranked first by 15 participants, XR-0.2× by 4, and KT by 2, and 16 of 21 ranked XR-1× above XR-0.2× (Table 2, panel B).
On the predefined measures, the two XR modes were therefore equivalent or inconclusive, apart from the designed difference in duration, whereas the preference ranking favored XR-1×. Taken at face value, the two led to different conclusions.
4.2. Stage 2: Physiological Differentiation (RQ1)
Having established that the predefined measures did not differentiate XR-1× from XR-0.2× (Section 4.1), we turn to the physiological measures to test whether autonomic arousal patterns reveal differences between these modes (RQ1).
Electrodermal activity (EDA). In contrast to the predefined measures, phasic EDA differed strongly between the two XR modes (Table 3 and Table 4 and Figure 4). SCR rate (η2p = 0.62) and phasic area per minute (η2p = 0.61) showed very large mode effects that survived Holm adjustment across the seven physiological features (adjusted p < 0.001). XR-0.2× produced lower phasic activity than XR-1× on both features (dz = −1.42 and −1.85) and fewer SCRs than KT, whereas XR-1× and KT did not differ in SCR rate; on phasic area, XR-1× exceeded KT and XR-0.2× did not differ from it (Table 4). The contrast between the XR modes held for individuals: phasic area was lower in XR-0.2× for all 20 participants and SCR rate for 19 (Figure 8). Tonic EDA (SCL mean and slope) and SCR amplitude did not differ between modes (all p ≥ 0.14), consistent with the higher sensitivity of phasic features in short windows.
While EDA captures sympathetic activation (arousal), heart rate variability (HRV) provides complementary information about parasympathetic (vagal) activity.
Heart rate variability (HRV). RMSSD showed a trend toward higher values in XR-1× (Table 5 and Table 6 and Figure 5). Its mode effect (η2p = 0.15) did not survive adjustment across the seven features (adjusted p = 0.25), but the contrast between the XR modes was significant within RMSSD (Holm-corrected p = 0.041, dz = −0.61), which meets the criterion for a trend (Section 3.6.2); XR-1× was also higher than KT, whereas XR-0.2× and KT did not differ. SDNN showed no mode effect. Because XR-1× trials were the shortest, and in T1 mostly under one minute, where RMSSD estimates are least reliable, the trend needs confirmation with longer windows.
In answer to RQ1, phasic EDA clearly differentiated two XR modes that the predefined measures did not, and RMSSD showed a trend in the same comparison. Because the features were computed over whole trials, the difference describes the trials as experienced, including the longer watching in XR-0.2×, and does not show in which phase it arose (Section 3.6.2).
4.3. Open-Ended Responses
Fifteen of the 21 participants commented on replay speed, the most frequent topic after the physical effort of kinesthetic teaching (Table 7; Figure 6). Ten described the pace of the slow replay as a cost, and nine of them ranked XR-1× above XR-0.2×. Some found it too slow or boring to watch: “Safety speed was a little too slow, it was boring to wait for the robot to finish the trace” (P04F). Boredom was mentioned only for the slow replay. Others said that only the full-speed replay kept the tempo of their own movement: “My actions are not only consist of points but also has the speed. So the safety speed didn’t feel it corresponded to my actions” (P10M).
The comments also explained the minority preference. Four of the five participants who ranked XR-0.2× higher, and two who did not, described the slow replay as safer, more reliable, more accurate, or more controlled: “Different speed makes it more reliable and secure” (P01M); “With same speed, uneasiness comes automatically, and person thinks things can go wrong fast” (P02F). These are perceptions rather than established differences: one participant found the slow replay the least accurate (P10F), and errors did not differ reliably between the XR modes (Section 4.1). One participant wrote that “Speed did not change much for me” (P03M), and six did not mention replay speed.
Beyond replay speed, comments on kinesthetic teaching centered on its physical effort, and comments on XR programming on its ease and on problems with hand input or calibration (Table 7).
4.4. Integration Across Evaluation Channels (RQ1 and RQ2)
The findings of Section 4.1, Section 4.2 and Section 4.3 were integrated for each research question at two levels (Section 3.7), across participants, in a joint display (Section 4.4.1; Table 8) and within participants, from a matrix of each participant’s data (Section 4.4.2; Table A1; Figure 8 and Figure 9). Section 5.1 summarizes the answer to the research questions.
4.4.1. Group Level: Joint Display
- RQ1. Three channels registered a difference between the two XR modes: the preference ranking, the physiology, and the open-ended responses (Figure 7; Table 8, RQ1). The predefined measures did not: usability, workload, and attempts were equivalent, and agency and errors were inconclusive. On its own, this row shows a discordance between the predefined measures and the other three channels.
- RQ2a: physiological differentiation. The physiology and comments independently indicated that the slow replay was experienced differently, and the comments expanded this finding by showing that the same change had two opposite meanings (Table 8, RQ2a). For most participants who commented on replay speed, the slower, less activating replay was a cost: ten described it as too slow, annoying, or boring, as out of tempo with their own movement, or as taking longer. For others it was a gain: six credited it with safety, reliability, accuracy, or control. The physiology could not tell these readings apart, because lower phasic activation is compatible both with understimulation and with reduced threat; only the comments distinguished them. The performance logs added that the extra time in XR-0.2× trials was spent watching. The questionnaire covered only one side. Its items on pace, time pressure and unease about the robot’s speed, address an interaction that is too fast and could therefore register the gain of a slower replay; neither differed between the modes [22]. No item asked about waiting, boredom, or tempo, so the questionnaire was silent on the cost. The only discordance was minor: one participant described the slow replay as annoying (P08F), whereas the NASA-TLX item that includes annoyance did not differ between the XR modes [22].
- RQ2b: the divergence in preference. Preference followed these two readings: nine of the 16 participants who ranked XR-1× higher described the slow pace as a cost, and four of the five who ranked XR-0.2× higher credited it with safety, reliability, accuracy, or control (Table 9, RQ2b). The physiology did not distinguish the two groups: phasic activity was lower in XR-0.2× in both, if anything more so in those who preferred it (Section 4.4.2). The same bodily change was therefore valued in opposite ways, and the comments, not the physiology, explained the divergence. Accuracy remained unresolved: two participants found the slow replay more accurate and one less, and the comparison of errors was inconclusive.
- Read together. The discordance in RQ1 was only apparent. The predefined measures did not contradict the preference; they were silent on what it rested on, and that was two sides of the same change: a cost of waiting for most, a gain in safety and control for a few.
4.4.2. Participant Level
Table A1 gives each participant’s data across channels, grouped by the XR mode the participant ranked higher; Figure 8 and Figure 9 show each participant’s physiological differences between the two XR modes.
- RQ1: The physiological differentiation held for individuals, whereas the equivalence on the questionnaire did not mean that participants rated the two modes alike. Phasic area was lower in XR-0.2× than in XR-1× for all 20 participants with physiological data, and SCR rate for 19 (Figure 8); RMSSD, reported as a trend, was lower for 15 (Figure 9). The questionnaire differences, in contrast, went both ways: 12 participants rated XR-1× as more usable and 9 as less usable; 9 rated it as less demanding and 10 as more demanding, with 2 ties; and 11 gave it higher agency ratings and 7 lower, with 3 ties (Table A1). Preference, too, went both ways at this level (16 and 5), and 14 of the 21 comments described a difference between the modes.
- RQ2a: the physiological differentiation. Whether participants wrote about the pace did not distinguish them physiologically. Phasic area was lower in XR-0.2× for all 10 participants who described the pace of the slow replay as a cost and for all 6 who did not mention replay speed, and SCR rate for all 10 and for 5 of the 6, with no consistent difference in the size of the contrast between the two groups (Table A1). The one participant who wrote that replay speed “did not change much” for him also showed the contrast (P03M). The comments therefore did not mirror the physiological change; they interpreted it, for the participants who chose to write about it.
- RQ2b: the divergence in preference. The same change was valued differently. The four participants with physiological data who ranked XR-0.2× higher showed the same decrease as the others, if anything larger (mean difference in phasic area 4.01 vs. 2.04 z units, and in SCR rate 1.63 vs. 1.28), and three of them credited the slow replay with reliability, security, accuracy, or control (P11F, P01M, and P02M); the fourth did not mention replay speed (P05F). RMSSD showed the same pattern: it was lower in XR-0.2× for 3 of the 4 and for 12 of the 16 who ranked XR-1× higher. The questionnaire differences, unlike the physiology, tended to follow preference: four of the five participants who ranked XR-0.2× higher also rated it as more usable, four as less demanding, and four as giving more agency. Among the 16 who ranked XR-1× higher, the differences leaned the other way but were smaller (usability: 11 favored XR-1× and 5 XR-0.2×; mean difference 0.16 points on the 21-point scale, against −0.93 in the minority), and workload and agency showed the same pattern (Table A1). In the group means (Table 3), these differences partly offset each other. With five participants in the minority, these are observations about this sample, not a tested association.
5. Discussion
5.1. Principal Findings
Predefined measures and preference diverged because the measures were silent, not because they were wrong. Concurrent physiology showed that the slow replay was associated with a different physiological profile in nearly every participant and their comments showed that this change had two opposite meanings: a cost for most of those who commented on the pace, and a gain for most of those who preferred the slow replay.
On RQ1, the answer was yes at both levels. The two XR modes were equivalent on usability, workload, and attempts and inconclusive on agency and errors, yet 16 of 21 participants preferred full-speed replay. Phasic EDA differentiated the modes strongly, with fewer SCRs and less phasic activity in the slow-replay trials, and RMSSD showed a trend in the same comparison. At the participant level, the physiological difference appeared in nearly every participant, whereas the questionnaire differences went both ways.
On RQ2a, the comments gave the physiological difference its meaning, and that meaning was not the same for everyone. Ten participants described the slower pace as a cost: waiting, boredom, a mismatch with their own tempo, or a longer execution. Six credited it with safety, reliability, accuracy, or control. The physiological contrast was present whether or not participants wrote about the pace, so the comments interpreted the change rather than mirrored it.
On RQ2b, preference followed these two readings. Most participants who preferred XR-1× described the slow pace as a cost, and four of the five who preferred XR-0.2× credited it with safety, reliability, accuracy, or control. Their physiology, however, did not differ: the drop in phasic activity was the same, if anything larger, in those who preferred the slow replay. The same bodily change was thus valued in opposite ways.
5.2. What the Physiological Difference May Reflect
Lower phasic EDA indicates less sympathetic activation during the slow-replay trials; it does not by itself say what participants experienced. Several explanations are compatible with the data, and the present design cannot fully separate them.
The simplest is a composition explanation. XR-0.2× trials contained more of a less activating activity: watching made up an estimated 56% of an XR-0.2× trial and 20% of an XR-1× trial (Section 3.6.2), and watching involves less movement and fewer discrete events, both of which elicit SCRs [15]. On this explanation, part of the difference reflects what participants were doing rather than how they felt about it. The participant level fits it: the contrast was present both in participants who described the pace as a cost and in those who never mentioned it (Section 4.4.2), although not mentioning the pace does not mean that it went unnoticed. Composition limits what the EDA difference alone can show, but it does not rule out the experiential readings below, which the comments point to.
The comments suggest two such readings of the same lower activation, one for each side of the preference. The first is that waiting at one-fifth speed was understimulating or out of tempo. Theories of optimal arousal hold that experiences become aversive when stimulation is too low as well as too high [53,54,55], and boredom has been defined as the aversive state of wanting, but being unable, to engage attention; four participants used the words bored or boring. The autonomic signature of boredom is mixed, however: boredom has been found to combine lower skin conductance with rising heart rate [56], and with a slow cobot it was accompanied by higher heart rate and facial arousal [28]. Low phasic EDA is therefore consistent with understimulation, not a marker of boredom. A related cost concerns timing: with full-speed replay the robot reproduced the path at the speed at which it had been drawn, and three participants missed this correspondence in the slow replay, as in “the safety speed didn’t feel it corresponded to my actions” (P10M). The timing of a robot’s actions relative to its partner’s is central to perceived fluency [57] and delays between an action and its consequence can weaken the sense of agency [58]; the agency items asked about control in general, not about tempo.
The second reading is consistent with the interpretation offered by many participants who preferred the slow replay, describing it as safer, more reliable, or more controllable. Lower robot speed is associated with higher perceived safety [59,60], and in HRI, physiological arousal to robot motion has been read as anxiety that slower, safer motion reduces [61,62]. On this reading, the same drop in activation may reflect lower perceived threat rather than insufficient stimulation.
What the data do not support is that the slow replay was relaxing in a general sense. Relaxation would be expected to raise vagally mediated HRV, but RMSSD tended to be lower in XR-0.2× than in XR-1× (a trend; Section 4.2), and no participant described the slow replay as relaxing; those who preferred it described it as safer or more controlled. Physiology alone cannot decide between understimulation and reduced threat, and the comments show that both readings occurred, in different participants (Section 5.4). Separating them from composition would require phase-resolved analysis with equal-length watching windows, items or probes on stimulation, boredom, and perceived safety, and a control condition with the same waiting but full-speed motion, such as a delayed full-speed replay.
5.3. Why the Predefined Measures Were Silent
Participants were not unaware of what the slow replay changed: asked an open question, ten named its cost and six a gain in safety, reliability, accuracy, or control, without prompting. The silence of the questionnaire is therefore better explained by what it asked than by what participants could report. Three features of the measures may contribute.
First, the measures were oriented to overload and to the risk of a fast robot. Usability and workload describe pragmatic quality, that is, how well a system supports a task [63], and the questionnaire’s only items on pace asked about time pressure and unease about the robot’s speed (Section 3.5). Both address an interaction that is too fast, the risk that motivated the slowdown. Nothing asked about one that is too slow: waiting, slowness, or lack of stimulation. A slower replay can leave pragmatic quality unchanged while lowering hedonic qualities such as stimulation [64], which the questionnaire did not measure. The questionnaire could thus register one side of the change, the gain of a slower robot, but not the other, its cost. The participant level is consistent with this: the questionnaire differences followed preference most clearly among the five participants who preferred the slow replay, four of whom cited reliability, security, accuracy, or control, qualities that the usability and agency items partly address; among the majority, most of whom cited the pace as a cost, the differences were small (Section 4.4.2). The silence was therefore specific to the qualities on which most participants based their preference, although, with five participants in the minority, this is a pattern to test rather than a finding.
Second, ratings made once after each block may be insensitive to how long an experience lasted. Retrospective evaluations of affective episodes depend more on their most intense and final moments than on their duration. The slow replay mainly added duration: XR-0.2× trials took 81% longer without changing what participants had to do, so ratings of usability and workload made after the block would be expected to change little.
Third, the ranking was comparative. Comparative judgments can detect differences that separate ratings miss [65,66,67], and ranking the modes against each other may have made the difference in pace salient in a way that rating each block on its own did not. The data cannot separate these three explanations, but they lead to the same conclusion: equivalence on predefined measures is a statement about the constructs measured, not about the experience as a whole. Nor is it a statement about individuals: the equivalent group means combined individual differences in both directions (Section 4.4.2).
5.4. What Each Channel Added
Reading the channels together, and per participant, showed what each could and could not establish on its own.
The participant level added three points that the group averages could not show. First, the physiological difference was a shared response, not an average of mixed ones (RQ1): phasic area was lower in the slow-replay trials for every participant with physiological data, whereas the questionnaire differences went both ways. Second, the comments did not mirror the physiology (RQ2a): the contrast appeared in participants who described the pace as a cost, in the six who never mentioned it, and in the one who wrote that speed did not change much for him, so the absence of a comment was not the absence of an effect. Third, the same bodily response had different meanings (RQ2b): the four participants with physiological data who preferred the slow replay showed the same, if anything larger, drop in phasic activity as the others, and three of them described the slow replay as safer, more reliable, or more controlled, the reading discussed in Section 5.2.
Physiology added two things that the comments could not. The first is independence: the comments were written to justify a forced ranking, which yields an order even between options experienced alike, and the reasons people give for a choice can be constructed after it is made [19]. The EDA was recorded during the trials, before any ranking, and did not depend on what participants chose to write. The second is the separation of response from valuation: without physiology, the minority’s preference could have meant that the slow replay affected them differently, but their phasic activity dropped at least as much as the others’.
The comments, in turn, provided participants’ interpretations of the observed change. Physiology alone would have shown that the slow replay changed the bodily state of nearly every participant, but not whether for better or worse; read as a marker of stress, as physiological arousal to robot motion often is in HRI [61,62], it would even have favored the slow replay that most participants ranked lower. The questionnaire alone would have concluded that the two modes were the same. Only the comments showed that the same change was a cost for most of those who commented on the pace and a gain for most of those who preferred the slow replay, and on what grounds.
The channels were therefore complementary rather than convergent: each showed what the others could not, and the finding that one bodily change carried opposite valuations emerged only from their integration.
5.5. Implications for HRI Evaluation and Design
5.5.1. For HRI Evaluation
The study suggests five practices for HRI evaluations that compare closely matched conditions. First, when two conditions are claimed to be equivalent, equivalence should be tested rather than inferred from non-significant differences [49]; with paired data, the test needs no new data, and here it showed that two of the five predefined measures, agency and errors, could not be called equivalent. Second, a single open question is inexpensive and can be decisive: one end-of-session prompt was the only channel that named the qualities on which most participants based their preference. Third, physiology should not be read alone. A physiological difference shows whether, and in whom, conditions differed, but not whether for better or worse; here, the same drop in arousal was a cost for some participants and a gain for others, and read as a marker of stress it would have favored the less preferred mode. Fourth, integration should be explicit and, in within-subject studies, carried out at both levels. Classifying the fit between channels, including silence, turned an apparent contradiction into an interpretable result, and a joint display makes that step open to review [43,44]; a participant-level matrix then shows what group means cannot, here that the physiological contrast was shared by nearly everyone while equivalent questionnaire means hid individual differences that partly followed preference. Fifth, when a design change trades one quality for another, both should be measured. A slowdown can reduce the risk of overload and unease while adding waiting, so items on stimulation, boredom, or waiting belong beside items on workload and perceived safety.
5.5.2. For XR Robot Programming
For XR robot programming, the results suggest that a safety-motivated slowdown of the replay is not experientially neutral. It was a cost for most participants who commented on the pace and a gain in perceived safety, reliability, or control for most of those who preferred it. These findings identify replay speed as a potentially consequential interaction-design parameter and motivate further investigation of configurable or task-dependent replay strategies, subject to applicable safety requirements. Three design options follow, each to be tested: letting operators choose the replay speed within the limits that safety requirements set for operation near the robot [ISO 10218-1:2025]; replaying at the speed of the demonstration by default and offering slow replay for verification; and, where XR allows it, previewing the path at full speed on a virtual robot before a slower physical execution. Because the present study measured neither perceived nor objective safety, and the comparison of errors was inconclusive, evaluations of such options should measure waiting and fluency [57] alongside perceived safety [68].
5.6. Limitations and Future Work
This was a secondary analysis of a study that was not designed as a mixed-methods study. The convergent design was possible because the channels were collected concurrently, but the qualitative strand is thin: one comment per participant, written at the end of the session, in a language that was not the first language of most participants. The comments explained the rankings, so the two are not independent, and the coders could not be blind to preference. The comments describe each mode as a whole, whereas the physiological features describe individual trials.
The sample was small and homogeneous (N = 21; n = 20 for physiology; young university volunteers), which limits both the equivalence tests and the participant-level analysis. Equivalence was bounded at ±0.5 dz, so smaller differences between the XR modes cannot be excluded, and with N = 21 these tests have limited power. The participant-level reading was descriptive. Questionnaire differences were counted by direction, so small differences on a 21-point scale counted as much as large ones. Only five participants, four of them with physiological data, preferred the slow replay, so both the finding that they showed the same physiological change and the pattern in their questionnaire differences need confirmation in samples with more such participants.
The physiological analysis used whole-trial windows, which differ in composition between the modes (Section 3.6.2), and did not separate the programming and watching phases. The SCR threshold was relative to each trial’s phasic variability, and no usable baseline was available. HRV was estimated from short windows, and within-participant standardization inflated the values of two participants whose trials varied little; the RMSSD trend held without them, but it needs confirmation with longer windows. Neither perceived nor objective safety was measured, so the minority’s safety reasoning could not be compared with either. The tasks involved one robot, one XR system, and path-programming tasks, and may not generalize to other forms of robot programming.
The integration was carried out by researchers who knew the results of every stage. Its rows were set by the research questions and its levels by the design, but the stance recorded in each cell involved judgment; the joint display and the full participant-level matrix are published so that readers can check it.
Future work should analyze the programming and watching phases separately with equal-length windows, add a control condition that separates waiting from replay speed, such as a delayed full-speed replay, include brief in-the-moment probes and items on stimulation, boredom, and perceived safety, and test participant-level associations between physiology, questionnaire ratings, and open-ended responses in samples designed for it.
6. Conclusions
Two XR robot-programming modes that differed only in replay speed were equivalent on usability, workload, and attempts, yet most participants preferred full-speed replay. Read together, the evaluation channels resolved this apparent contradiction. Concurrent phasic EDA showed that the slow replay changed participants’ bodily state, strongly and in nearly every participant, including those who never mentioned the pace and those who preferred the slow replay. The open-ended responses suggested two contrasting interpretations of the condition associated with that physiological difference: waiting, boredom, or a tempo that no longer matched their own for most of those who commented on the pace, and greater safety, reliability, accuracy, or control for four of the five who preferred the slow replay. The predefined measures were not wrong; they were silent on the qualities on which most participants based their preference.
The study offers two readings. For HRI evaluation, equivalence on predefined measures is a statement about the constructs measured, not about the experience; it should be tested rather than assumed and complemented by at least one open question. Physiology can show whether, and in whom, conditions differed, independently of what participants were asked or chose to say, but not whether the difference was for better or worse. A largely consistent physiological contrast coexisted with divergent evaluations of replay speed, highlighting the distinct information provided by physiological measures and open-ended responses, and read alone as stress it would have favored the less preferred mode. Participants’ comments supply that meaning, and integration at the participant level shows whether a divergent preference reflects a different response or a different valuation. For XR robot programming, slowing the replay for safety is not experientially neutral: it imposed a cost on most participants who commented on the pace and reassured a few, which argues for replay speed as an adjustable setting, within safety requirements, rather than a fixed default. Both readings rest on a small sample, one task, and whole-trial physiology, and call for confirmation with phase-resolved measures, items on stimulation and perceived safety, and richer qualitative data.
Supplementary Materials
The following supporting information can be downloaded at the website of this paper posted on Preprints.org, The processing scripts are archived at https://doi.org/10.5281/zenodo.19349295 and the raw EDA and ECG recordings at https://doi.org/10.5281/zenodo.19352269. The free-text comments and their codes are given in Appendix A. Questionnaire, performance, and ranking data are available from the corresponding author on reasonable request.
Author Contributions
Conceptualization, N.O., O.E., G.L. and M.M.; methodology, N.O., O.E., G.L., M.M. and A.A.; software, N.O.; formal analysis, N.O., O.E., G.L. and A.A.; investigation, N.O. and O.E.; data curation, N.O. and O.E.; writing—original draft preparation, N.O.; writing—review and editing, N.O., O.E., G.L., M.M. and A.A.; visualization, N.O.; supervision, G.L. and M.M.; project administration, N.O., G.L. and M.M.; funding acquisition, G.L. and M.M. All authors have read and agreed to the published version of the manuscript.
Funding
This research was funded by the European Union’s Horizon Europe research and innovation programme through the project INVERSE (INteractive robots that intuitiVely lEarn to inVErt tasks by ReaSoning about their Execution), grant agreement No. 101136067.
Institutional Review Board Statement
I The study was conducted in accordance with the Declaration of Helsinki and approved by the Research Ethics Committee of Mondragon Unibertsitatea (code IEB-20241118, 18 November 2024) and by the Ethics Committee of Boğaziçi University (code E-84391427-050.04-211747).
Informed Consent Statement
Informed consent was obtained from all subjects involved in the study.
Data Availability Statement
The processing scripts are archived at https://doi.org/10.5281/zenodo.19349295 and the raw EDA and ECG recordings at https://doi.org/10.5281/zenodo.19352269. The free-text comments and their codes are given in Appendix A. Questionnaire, performance, and ranking data are available from the corresponding author on reasonable request.
Acknowledgments
The authors thank the participants and the team at Boğaziçi University who supported data collection.
Conflicts of Interest
The authors declare no conflicts of interest.
Abbreviations
The following abbreviations are used in this manuscript:
| ANOVA | analysis of variance |
| CI | confidence interval |
| CV | coefficient of variation of inter-beat intervals |
| ECG | electrocardiogram |
| EDA | electrodermal activity |
| HRI | human–robot interaction |
| HRV | heart rate variability |
| KT | kinesthetic teaching |
| MAD | median absolute deviation |
| RMSSD | root mean square of successive differences between inter-beat intervals |
| SCL | skin conductance level |
| SCR | skin conductance response |
| SDNN | standard deviation of inter-beat intervals |
| XR | extended reality |
| XR-1× | XR programming with replay at full speed |
| XR-0.2× | XR programming with replay at one-fifth speed |
Appendix A. Participant-Level Matrix
Table A1 lists every participant’s ranking and comment, with the codes from Table 8 and the differences between the two XR modes on the questionnaire constructs and in SCR rate and phasic area; it serves as the participant-level matrix (Section 3.7). Participants are grouped by the XR mode they ranked higher. Comments are reproduced verbatim except for corrected spelling and typing errors; one personal detail was removed.
Table A1.
Participant-level matrix: rankings of KT, XR-1×, and XR-0.2× (1 = most suitable), free-text comments, codes (Table 8), and the XR-1× minus XR-0.2× differences on the questionnaire constructs (points on the 21-point scale) and in SCR rate and phasic area (within-participant robust z units). Positive differences are higher in XR-1× (for workload, lower workload in XR-1×). P02F has no physiological data.
Table A1.
Participant-level matrix: rankings of KT, XR-1×, and XR-0.2× (1 = most suitable), free-text comments, codes (Table 8), and the XR-1× minus XR-0.2× differences on the questionnaire constructs (points on the 21-point scale) and in SCR rate and phasic area (within-participant robust z units). Positive differences are higher in XR-1× (for workload, lower workload in XR-1×). P02F has no physiological data.
| ID | Ranks | Comment | Codes | Δ Usability | Δ Workload | Δ Agency | Δ SCR rate | Δ Phasic area |
| Ranked XR-1× higher (n = 16) | ||||||||
| P01F | 3, 1, 2 | I used my right hand during the experiment but I felt like I would perform better if I used my left hand. Pinch movement could be edited to overcome this problem. | X2 | 0.67 | 0.00 | 0.50 | 0.83 | 2.16 |
| P03F | 3, 1, 2 | Robot controlled manually was hard to use. I felt challenged while using that. Also robot controlled with AR which is faster is the most suitable one I think. I get bored while waiting the slower robot controlled with AR. | R1, R1b, K1 | 0.17 | −0.50 | −5.50 | 0.46 | 2.55 |
| P04F | 3, 1, 2 | Using the robot manually was physically challenging, as I am [height and weight removed]. Safety speed was a little too slow, it was boring to wait for the robot to finish the trace. Real speed in AR was satisfactory in both sense: it was very easy to use and smooth. I also believe this system is very easy to learn how to use, even for people without any prior experience with AR or robots. | R1, R1b, R3, X1, K1 | −3.33 | −1.00 | 0.00 | 0.40 | 3.26 |
| P06F | 3, 1, 2 | The AR part was much more easier than physically moving the robot, so it was better. Also the same speed following my actions was better than the low speed. | R2, X1, K1 | 1.17 | 0.17 | 1.00 | 1.64 | 1.63 |
| P07F | 3, 1, 2 | Controlling robot manually was hard and needs physical power. I don’t think old people, children or some physically unable people could accomplish tasks easily. Controlling with AR is quite easy, and real robot could follow the route easily. | X1, K1 | 1.00 | 1.67 | 4.50 | 0.44 | 2.70 |
| P08F | 3, 1, 2 | Even though controlling the robot manually was a lot more precise and I could actually see what I was doing (glasses), the physical labour was so more exhausting that I preferred AR. The robot itself blocking my vision was another downside of manual control. With AR (Safety mode), I was greatly annoyed how slow the safety speed was. | R1, K1, K2 | −1.50 | 4.33 | 3.00 | 1.57 | 1.58 |
| P09F | 3, 1, 2 | I think the robot didn’t follow my path during the experiments (2 and 3) in AR | X2 | 0.17 | −1.50 | 2.00 | 1.32 | 3.87 |
| P10F | 1, 2, 3 | Robot controlled manually: Hard to use due to physical force needed. Most reliable and it gets the job done. Robot controlled with AR (same speed): this one felt like robot is not following accurately. Also moving my hand was harder than moving the robot. Robot controlled with AR (different speed): This one is by far the most that robot didn’t follow my instructions clearly. Also it was unnecessarily slow. I felt bored | R1, R1b, R5, X2, K1, K2 | 0.67 | 5.00 | 0.50 | 1.44 | 2.18 |
| P03M | 3, 1, 2 | I feel that AR requires very less physical force so I would choose AR. AR can use some precision calibration to work as perfect. I think it is near perfect, but not perfect. Overall better than physical control. Speed did not change much for me | R7, X1, X2, K1 | 0.17 | 0.00 | 0.00 | 1.30 | 1.21 |
| P04M | 2, 1, 3 | The safety speed was too slow. It became boring. AR is good because it didn’t require me to think how to manipulate the joints of the robot. Manual is good because it goes exactly where you tell it to go. The AR had some misses with the trajectory. AR also felt good because manual control takes a lot of physical effort. | R1, R1b, X1, X2, K1, K2 | 1.33 | −0.50 | 0.00 | 2.53 | 0.75 |
| P05M | 2, 1, 3 | I failed too many times when I have to push the cube. I think calibration of my hand with robot can be improved. | X2 | 3.00 | 1.33 | 3.00 | 0.81 | 2.63 |
| P06M | 3, 1, 2 | It was physically hard to control the robot manually and it was almost painful to watch robot go slower than before. | R1, K1 | −0.83 | 0.17 | 0.50 | 1.91 | 0.95 |
| P07M | 3, 1, 2 | In a scenario where I’ll use the robot multiple times, I wouldn’t want to move it manually every time. In general, and in a safe space, I would use the same speed option since it takes less to execute and I can move my hand slowly if I need to anyway. The safe speed option might be better if there is always risk of collision and I want to be safe. | R2, R4, R6, K1 | 1.33 | 0.17 | 0.50 | 4.08 | 1.68 |
| P08M | 3, 1, 2 | The same speed was less accurate than different one but I really enjoyed when I’m in experiment due to its speed. However, controlling the robot manually was too difficult. It requires high physical strength to move the robot. And it is not comfortable. | R3, R6, K1 | −1.17 | −1.00 | 1.50 | 1.47 | 1.19 |
| P09M | 3, 1, 2 | Manual controlling is hard to do what I actually want. Specially in vertical axis, it was hard to do what I want. | K1 | −0.50 | −0.83 | −0.50 | −0.43 | 1.89 |
| P10M | 2, 1, 3 | My actions are not only consist of points but also has the speed. So the safety speed didn’t feel it corresponded to my actions. I really enjoyed the same speed. I wanted more same points fast and other slow and I enjoyed to see robot follow me in that way. Manual control felt the most accurate one, however I had to consider how to move joints, it felt too much work. | R2, R3, K1, K2 | 0.17 | 3.67 | −1.50 | 0.65 | 2.37 |
| Ranked XR-0.2× higher (n = 5) | ||||||||
| P02F | 2, 3, 1 | Even though manual control felt more controlled and safe, it’s tedious. I’d prefer robot controlled with AR, with different speed (slower than human motion). Because once totally tested and calibrated, I think this approach is the least tiring and easiest. With same speed, uneasiness comes automatically, and person thinks things can go wrong fast. | R6, X1, K1, K2 | −3.17 | 0.17 | −2.50 | n/a | n/a |
| P05F | 3, 2, 1 | Controlling robot manually was clearly more laborious and required much more physical activity. Thus, I felt more comfortable with AR setup for long term usage. Controlling robot with AR via hand was also a little bit tricky. It would be very convenient to perform the same task with a remote controller. | X1, X2, K1 | −1.17 | −0.17 | −4.00 | 1.08 | 2.90 |
| P11F | 3, 2, 1 | The different speed seemed to replicate my actions the best as it slowed down when it needed to in order to execute correctly. Manual version was physically demanding, and the same speed one was not accurately executing what it needed to. Overall, it seems like an incredible useful project and I was happy to be a tiny part of it. | R6, K1 | −0.33 | −0.83 | −5.00 | 2.22 | 2.56 |
| P01M | 3, 2, 1 | Different speed makes it more reliable and secure. It felt like the robot solved a different task than me with AR. I had to take my arm into account, as well as my hand but the robot was coming from a bird’s eye view. The robot may have had a better trajectory drawn if this weren’t the case. Thanks! | R6, X2 | 1.17 | −0.33 | 2.50 | 1.82 | 6.54 |
| P02M | 1, 3, 2 | Even though manual control was more laborious, at least it did what I want it to do. There was a calibration issues with the AR parts. The slower was more like to the real “control” part but it was slow | R1, R6, X2, K1, K2 | −1.17 | −5.00 | −9.50 | 1.39 | 4.03 |
References
- Apraiz, A.; Lasa, G.; Mazmela, M. Evaluation of User Experience in Human–Robot Interaction: A Systematic Literature Review. Int. J. Soc. Robot. 2023, 15, 187–210. [Google Scholar] [CrossRef]
- Hopko, S.; Wang, J.; Mehta, R. Human Factors Considerations and Metrics in Shared Space Human-Robot Collaboration: A Systematic Review. Front. Robot. AI 2022, 9, 799522. [Google Scholar] [CrossRef] [PubMed]
- Abdulazeem, N.; Hu, Y. Human Factors Considerations for Quantifiable Human States in Physical Human–Robot Interaction: A Literature Review. Sensors 2023, 23, 7381. [Google Scholar] [CrossRef] [PubMed]
- Lasota, P.A.; Fong, T.; Shah, J.A. A Survey of Methods for Safe Human-Robot Interaction. Found. Trends Robot. 2017, 5, 261–349. [Google Scholar] [CrossRef]
- Ikeda, B.; Szafir, D. PRogramAR: Augmented Reality End-User Robot Programming. ACM Trans. Hum.-Robot Interact. 2024, 13. [Google Scholar] [CrossRef]
- Doğangün, F.; Bahar, S.; Yildirim, Y.; Temir, B.T.; Ugur, E.; Dogan, M.D. RAMPA: Robotic Augmented Reality for Machine Programming by DemonstrAtion. IEEE Robot. Autom. Lett. 2025, 10, 3795–3802. [Google Scholar] [CrossRef]
- Prati, E.; Borsci, S.; Peruzzini, M.; Pellicciari, M. A Systematic Literature Review of User Experience Evaluation Scales for Human-Robot Collaboration. In Transdisciplinarity and the Future of Engineering; Advances in Transdisciplinary Engineering; Moser, B.R., et al., Eds.; IOS Press: Amsterdam, The Netherlands, 2022; Vol. 28, pp. 13–22. [Google Scholar] [CrossRef]
- Sarvghadi, H.; Reinhardt, A.; Semmelhack, E.A. A Survey of Wearable Devices to Capture Human Factors for Human-Robot Collaboration. Pervasive Mob. Comput. 2025, 110, 102048. [Google Scholar] [CrossRef]
- Zhang, Q.; Chen, X.; Zhan, Q.; Yang, T.; Xia, S. Respiration-Based Emotion Recognition with Deep Learning. Comput. Ind. 2017, 92–93, 84–90. [Google Scholar] [CrossRef]
- 1Zhang, Y.; Yadav, A.; Hopko, S.K.; Mehta, R.K. Gaze We Trust: Comparing Eye Tracking, Self-Report, and Physiological Indicators of Dynamic Trust during HRI. In Companion of the 2024 ACM/IEEE International Conference on Human-Robot Interaction; ACM: New York, NY, USA, 2024; pp. 1188–1193. [Google Scholar] [CrossRef]
- Roy, R.N.; Drougard, N.; Gateau, T.; Dehais, F.; Chanel, C.P.C. How Can Physiological Computing Benefit Human-Robot Interaction? Robotics 2020, 9, 100. [Google Scholar] [CrossRef]
- Ricci, G.; De Crescenzio, F.; Santhosh, S.; Magosso, E.; Ursino, M. Relationship between Electroencephalographic Data and Comfort Perception Captured in a Virtual Reality Design Environment of an Aircraft Cabin. Sci. Rep. 2022, 12. [Google Scholar] [CrossRef] [PubMed]
- Ricci, A.; Ronca, V.; Capotorto, R.; Giorgi, A.; Vozzi, A.; Germano, D.; Borghini, G.; Di Flumeri, G.; Babiloni, F.; Aricò, P. Understanding the Unexplored: A Review on the Gap in Human Factors Characterization for Industry 5.0. Appl. Sci. 2025, 15, 1822. [Google Scholar] [CrossRef]
- Cowley, B.; Filetti, M.; Lukander, K.; Torniainen, J.; Henelius, A.; Ahonen, L.; Barral, O.; Kosunen, I.; Valtonen, T.; Huotilainen, M.; et al. The Psychophysiology Primer: A Guide to Methods and a Broad Review with a Focus on Human–Computer Interaction. Found. Trends Hum.-Comput. Interact. 2016, 9, 151–308. [Google Scholar] [CrossRef]
- Boucsein, W. Electrodermal Activity, 2nd ed.; Springer: New York, NY, USA, 2012. [Google Scholar] [CrossRef]
- Halbig, A.; Latoschik, M.E. A Systematic Review of Physiological Measurements, Factors, Methods, and Applications in Virtual Reality. Front. Virtual Real. 2021, 2, 694567. [Google Scholar] [CrossRef]
- Veling, L.; McGinn, C. Qualitative Research in HRI: A Review and Taxonomy. Int. J. Soc. Robot. 2021, 13, 1689–1709. [Google Scholar] [CrossRef]
- Russell, J.A. Core Affect and the Psychological Construction of Emotion. Psychol. Rev. 2003, 110, 145–172. [Google Scholar] [CrossRef] [PubMed]
- Johansson, P.; Hall, L.; Sikström, S.; Tärning, B.; Lind, A. How Something Can Be Said about Telling More than We Can Know: On Choice Blindness and Introspection. Conscious. Cogn. 2006, 15, 673–692. [Google Scholar] [CrossRef] [PubMed]
- Wilson, T.D.; Dunn, E.W. Self-Knowledge: Its Limits, Value, and Potential for Improvement. Annu. Rev. Psychol. 2004, 55, 493–518. [Google Scholar] [CrossRef] [PubMed]
- Lawrence, S.; Azizi, N.; Fan, K.; Jouaiti, M.; Hoey, J.; Nehaniv, C.L.; Dautenhahn, K. Examining the Impact of Robot Norm Violations on Participants’ Trust, Discomfort, Behaviour and Physiological Responses: A Mixed Method Approach. ACM Trans. Hum.-Robot Interact. 2025, 14. [Google Scholar] [CrossRef]
- Escallada, O.; Osa, N.; Lasa, G.; Mazmela, M.; Doğangün, F.; Yildirim, Y.; Bahar, S.; Ugur, E. Human Attitudes in Robotic Path Programming: A Pilot Study of User Experience in Manual and XR-Controlled Robotic Arm Manipulation. Multimodal Technol. Interact. 2025, 9, 27. [Google Scholar] [CrossRef]
- Yahia, E.; Magnani, F.; Joblot, L.; Passalacqua, M.; Pellerin, R. Exploring the Effects of Industry 4.0/5.0 on Human Factors: A Preliminary Systematic Literature Review. IFAC-PapersOnLine 2024, 58, 539–544. [Google Scholar] [CrossRef]
- De Nobile, A.; Bibbo, D.; Russo, M.; Conforto, S. A Focus on Quantitative Methods to Assess Human Factors in Collaborative Robotics. Int. J. Ind. Ergon. 2024, 104, 103663. [Google Scholar] [CrossRef]
- Liu, Y.; Caldwell, G.; Rittenbruch, M.; Belek Fialho Teixeira, M.; Burden, A.; Guertler, M. What Affects Human Decision Making in Human–Robot Collaboration?: A Scoping Review. Robotics 2024, 13, 30. [Google Scholar] [CrossRef]
- Hart, S.G.; Staveland, L.E. Development of NASA-TLX (Task Load Index): Results of Empirical and Theoretical Research. Adv. Psychol. 1988, 52, 139–183. [Google Scholar] [CrossRef]
- Brooke, J. SUS: A “Quick and Dirty” Usability Scale. In Usability Evaluation in Industry; Jordan, P.W., Thomas, B., Weerdmeester, B.A., McClelland, I.L., Eds.; Taylor & Francis: London, UK, 1996; pp. 189–194. [Google Scholar]
- Prajod, P.; Lavit Nicora, M.; Mondellini, M.; Falerni, M.M.; Vertechy, R.; Malosio, M.; André, E. Flow in Human-Robot Collaboration—Multimodal Analysis and Perceived Challenge Detection in Industrial Scenarios. Front. Robot. AI 2024, 11, 1393795. [Google Scholar] [CrossRef] [PubMed]
- Hsieh, H.F.; Shannon, S.E. Three Approaches to Qualitative Content Analysis. Qual. Health Res. 2005, 15, 1277–1288. [Google Scholar] [CrossRef] [PubMed]
- Kivikangas, J.M.; Chanel, G.; Cowley, B.; Ekman, I.; Salminen, M.; Järvelä, S.; Ravaja, N. A Review of the Use of Psychophysiological Methods in Game Research. J. Gaming Virtual Worlds 2011, 3, 181–199. [Google Scholar] [CrossRef] [PubMed]
- Bosta, A.; Vosinakis, S. A Multimodal Approach to User Experience Evaluation: Integration of Physiological, Behavioral, Contextual and Self-Report Data with UserSence. In Proceedings of the 3rd International Conference of the ACM Greek SIGCHI Chapter (CHIGreece 2025); ACM: New York, NY, USA, 2025; pp. 182–187. [Google Scholar] [CrossRef]
- Groechel, T.R.; Walker, M.E.; Chang, C.T.; Rosen, E.; Forde, J.Z. A Tool for Organizing Key Characteristics of Virtual, Augmented, and Mixed Reality for Human-Robot Interaction Systems: Synthesizing VAM-HRI Trends and Takeaways. IEEE Robot. Autom. Mag. 2022, 29, 35–44. [Google Scholar] [CrossRef]
- Wang, X.; Shen, L.; Lee, L.H. A Systematic Review of XR-Enabled Remote Human-Robot Interaction Systems. ACM Comput. Surv. 2025, 57, 273. [Google Scholar] [CrossRef]
- Escallada, O.; Lasa, G.; Mazmela, M.; Apraiz, A.; Osa, N.; Nguyen Ngoc, H. Assessing Human Factors in Virtual Reality Environments for Industry 5.0: A Comprehensive Review of Factors, Metrics, Techniques, and Future Opportunities. Information 2025, 16, 35. [Google Scholar] [CrossRef]
- Kim, E.; Peysakhovich, V.; Roy, R.N. Impact of Communication Delay and Temporal Sensitivity on Perceived Workload and Teleoperation Performance. In Proceedings of the ACM Symposium on Applied Perception (SAP 2021); 2021, ACM: New York, NY, USA, 2021. [Google Scholar] [CrossRef]
- Gallipoli, M.; Buonocore, S.; Selvaggio, M.; Fontanelli, G.A.; Grazioso, S.; Di Gironimo, G. A Virtual Reality-Based Dual-Mode Robot Teleoperation Architecture. Robotica 2024, 42, 1935–1958. [Google Scholar] [CrossRef]
- Luz, R.; Silva, J.L.; Ventura, R. Enhanced Teleoperation Interfaces for Multi-Second Latency Conditions: System Design and Evaluation. IEEE Access 2023, 11, 10935–10953. [Google Scholar] [CrossRef]
- Lee, C.; Bonebrake, S.; Höllerer, T.; Bowman, D.A. The Role of Latency in the Validity of AR Simulation. In Proceedings of the 2010 IEEE Virtual Reality Conference (VR); IEEE: Piscataway, NJ, USA, 2010; pp. 11–18. [Google Scholar] [CrossRef]
- Apraiz, A.; Lasa, G.; Mazmela, M.; Arana-Arexolaleiba, N.; Serrano Muñoz, A.; Elguea, Í.; Etxabe, A. Evaluating the Effect of Speed and Acceleration on Human Factors during an Assembly Task in Human–Robot Interaction (HRI). Int. J. Soc. Robot. 2025, 17, 211–256. [Google Scholar] [CrossRef]
- Rakita, D.; Mutlu, B.; Gleicher, M. Effects of Onset Latency and Robot Speed Delays on Mimicry-Control Teleoperation. In Proceedings of the 2020 ACM/IEEE International Conference on Human-Robot Interaction; ACM: New York, NY, USA, 2020; pp. 519–527. [Google Scholar] [CrossRef]
- Hoffman, G.; Breazeal, C. Effects of Anticipatory Action on Human-Robot Teamwork Efficiency, Fluency, and Perception of Team. In Proceedings of the ACM/IEEE International Conference on Human-Robot Interaction; ACM: New York, NY, USA, 2007; pp. 1–8. [Google Scholar]
- Bartkowski, W.; Nowak, A.; Czajkowski, F.I.; Schmidt, A.; Müller, F. Sync: Exploring Synchronization to Increase Trust Between Humans and Non-Humanoid Robots. In Proceedings of the 2023 CHI Conference on Human Factors in Computing Systems; 2023, ACM: New York, NY, USA, 2023. [Google Scholar] [CrossRef]
- Fetters, M.D.; Curry, L.A.; Creswell, J.W. Achieving Integration in Mixed Methods Designs: Principles and Practices. Health Serv. Res. 2013, 48, 2134–2156. [Google Scholar] [CrossRef] [PubMed]
- O’Cathain, A.; Murphy, E.; Nicholl, J. The Quality of Mixed Methods Studies in Health Services Research. J. Health Serv. Res. Policy 2008, 13, 92–98. [Google Scholar] [CrossRef] [PubMed]
- Rheinberg, F.; Vollmeyer, R.; Engeser, S. Flow Short Scale. PsycTESTS Dataset 2016. [Google Scholar] [CrossRef]
- Tapal, A.; Oren, E.; Dar, R.; Eitam, B. The Sense of Agency Scale: A Measure of Consciously Perceived Control over One’s Mind, Body, and the Immediate Environment. Front. Psychol. 2017, 8, 1552. [Google Scholar] [CrossRef] [PubMed]
- Charalambous, G.; Fletcher, S.; Webb, P. The Development of a Scale to Evaluate Trust in Industrial Human-Robot Collaboration. Int. J. Soc. Robot. 2016, 8, 193–209. [Google Scholar] [CrossRef]
- Lakens, D. Equivalence Tests: A Practical Primer for t Tests, Correlations, and Meta-Analyses. Soc. Psychol. Personal. Sci. 2017, 8, 355–362. [Google Scholar] [CrossRef] [PubMed]
- Lakens, D.; Scheel, A.M.; Isager, P.M. Equivalence Testing for Psychological Research: A Tutorial. Adv. Methods Pract. Psychol. Sci. 2018, 1, 259–269. [Google Scholar] [CrossRef]
- Braithwaite, J.J.; Watson, D.G.; Jones, R.; Rowe, M. A Guide for Analysing Electrodermal Activity (EDA) & Skin Conductance Responses (SCRs) for Psychological Experiments; University of Birmingham: Birmingham, UK, 2013; Technical Report; Selective Attention & Awareness Laboratory. [Google Scholar]
- Shaffer, F.; Ginsberg, J.P. An Overview of Heart Rate Variability Metrics and Norms. Front. Public Health 2017, 5, 258. [Google Scholar] [CrossRef] [PubMed]
- Laborde, S.; Mosley, E.; Thayer, J.F. Heart Rate Variability and Cardiac Vagal Tone in Psychophysiological Research: Recommendations for Experiment Planning, Data Analysis, and Data Reporting. Front. Psychol. 2017, 8, 213. [Google Scholar] [CrossRef] [PubMed]
- Reimer, B.; Mehler, B.; Coughlin, J.F.; Godfrey, K.M.; Tan, C. An On-Road Assessment of the Impact of Cognitive Workload on Physiological Arousal in Young Adult Drivers. In Proceedings of the 1st International Conference on Automotive User Interfaces and Interactive Vehicular Applications (AutomotiveUI 2009); ACM: New York, NY, USA, 2009; pp. 115–118. [Google Scholar] [CrossRef]
- Reimer, B.; Mehler, B. The Impact of Cognitive Workload on Physiological Arousal in Young Adult Drivers: A Field Study and Simulation Validation. Ergonomics 2011, 54, 932–942. [Google Scholar] [CrossRef] [PubMed]
- Handrich, S.; Dinges, L.; Al-Hamadi, A.; Werner, P.; Saxen, F.; Al Aghbari, Z. Simultaneous Prediction of Valence/Arousal and Emotion Categories and Its Application in an HRC Scenario. J. Ambient Intell. Humaniz. Comput. 2021, 12, 57–73. [Google Scholar] [CrossRef]
- Merrifield, C.; Danckert, J. Characterizing the Psychophysiological Signature of Boredom. Exp. Brain Res. 2014, 232, 481–491. [Google Scholar] [CrossRef] [PubMed]
- Hoffman, G. Evaluating Fluency in Human-Robot Collaboration. IEEE Trans. Hum.-Mach. Syst. 2019, 49, 209–218. [Google Scholar] [CrossRef]
- Wen, W.; Imamizu, H. The Sense of Agency in Perception, Behaviour and Human–Machine Interactions. Nat. Rev. Psychol. 2022, 1, 211–222. [Google Scholar] [CrossRef]
- Rubagotti, M.; Tusseyeva, I.; Baltabayeva, S.; Summers, D.; Sandygulova, A. Perceived Safety in Physical Human Robot Interaction: A Survey. Robot. Auton. Syst. 2022, 151, 104047. [Google Scholar] [CrossRef]
- Akalin, N.; Kristoffersson, A.; Loutfi, A. Do You Feel Safe with Your Robot? Factors Influencing Perceived Safety in Human-Robot Interaction Based on Subjective and Objective Measures. Int. J. Hum.-Comput. Stud. 2022, 158, 102744. [Google Scholar] [CrossRef]
- Kulić, D.; Croft, E.A. Physiological and Subjective Responses to Articulated Robot Motion. Robotica 2007, 25, 13–27. [Google Scholar] [CrossRef]
- Arai, T.; Kato, R.; Fujita, M. Assessment of Operator Stress Induced by Robot Collaboration in Assembly. CIRP Ann. 2010, 59, 5–8. [Google Scholar] [CrossRef]
- Hassenzahl, M. The Thing and I: Understanding the Relationship between User and Product. In Funology: From Usability to Enjoyment; Blythe, M.A., Overbeeke, K., Monk, A.F., Wright, P.C., Eds.; Kluwer Academic Publishers: Dordrecht, The Netherlands, 2003; pp. 31–42. [Google Scholar] [CrossRef]
- Hassenzahl, M. The Hedonic/Pragmatic Model of User Experience. In Towards a UX Manifesto; Law, E., Vermeeren, A., Hassenzahl, M., Blythe, M., Eds.; COST294-MAUSE Affiliated Workshop: Lancaster, UK, 2007; pp. 10–14. [Google Scholar]
- Yannakakis, G.N.; Cowie, R.; Busso, C. The Ordinal Nature of Emotions: An Emerging Approach. IEEE Trans. Affect. Comput. 2021, 12, 16–35. [Google Scholar] [CrossRef]
- Goffin, R.D.; Olson, J.M. Is It All Relative? Comparative Judgments and the Possible Improvement of Self-Ratings and Ratings of Others. Perspect. Psychol. Sci. 2011, 6, 48–60. [Google Scholar] [CrossRef] [PubMed]
- Yannakakis, G.N.; Martínez, H.P. Ratings Are Overrated! Front. ICT 2015, 2, 13. [Google Scholar] [CrossRef]
- Akalin, N.; Kiselev, A.; Kristoffersson, A.; Loutfi, A. A Taxonomy of Factors Influencing Perceived Safety in Human–Robot Interaction. Int. J. Soc. Robot. 2023, 15, 1993–2004. [Google Scholar] [CrossRef]
Figure 1.
Analysis design. Five evaluation channels of four kinds, collected in the same sessions, were analyzed in three stages and then integrated for each research question (RQ1, RQ2a, RQ2b) at the group and participant levels.
Figure 1.
Analysis design. Five evaluation channels of four kinds, collected in the same sessions, were analyzed in three stages and then integrated for each research question (RQ1, RQ2a, RQ2b) at the group and participant levels.

Figure 2.
Experimental setup. Left: kinesthetic teaching, in which the participant guides the UR10 arm by hand to record a trajectory. Right: XR programming with a Meta Quest 3 headset running RAMPA. Faces are blurred.
Figure 2.
Experimental setup. Left: kinesthetic teaching, in which the participant guides the UR10 arm by hand to record a trajectory. Right: XR programming with a Meta Quest 3 headset running RAMPA. Faces are blurred.

Figure 3.
Physiological recording setup: EDA electrodes on the index and middle fingers of the non-dominant hand, ECG electrodes, and a Bitbrain Versatile Bio amplifier streaming to the acquisition computer at 256 Hz.
Figure 3.
Physiological recording setup: EDA electrodes on the index and middle fingers of the non-dominant hand, ECG electrodes, and a Bitbrain Versatile Bio amplifier streaming to the acquisition computer at 256 Hz.

Figure 4.
Electrodermal activity across interaction modes (within-participant robust z scores; mean ± 95% CI; n = 20). Brackets mark Holm-corrected contrasts.
Figure 4.
Electrodermal activity across interaction modes (within-participant robust z scores; mean ± 95% CI; n = 20). Brackets mark Holm-corrected contrasts.

Figure 5.
Heart rate variability across interaction modes (within-participant robust z scores; mean ± 95% CI; n = 20). The bracket marks the Holm-corrected XR-1× vs. XR-0.2× contrast in RMSSD (trend).
Figure 5.
Heart rate variability across interaction modes (within-participant robust z scores; mean ± 95% CI; n = 20). The bracket marks the Holm-corrected XR-1× vs. XR-0.2× contrast in RMSSD (trend).

Figure 6.
Comments about replay speed in the open-ended responses, by which XR mode the participant ranked higher (N = 21; a participant can appear in more than one row).
Figure 6.
Comments about replay speed in the open-ended responses, by which XR mode the participant ranked higher (N = 21; a participant can appear in more than one row).

Figure 7.
D map of physiological profiles of each interaction mode on SCR rate, phasic area, and RMSSD (within-participant robust z scores; n = 20).
Figure 7.
D map of physiological profiles of each interaction mode on SCR rate, phasic area, and RMSSD (within-participant robust z scores; n = 20).

Figure 8.
Each participant’s mean SCR rate and phasic area in XR-1× and XR-0.2× (n = 20; within-participant robust z scores, mean of tasks). Lines are colored by which XR mode the participant ranked higher; the black line shows the mean. Phasic area was lower in in XR-0.2× for 20 of 20 participants.
Figure 8.
Each participant’s mean SCR rate and phasic area in XR-1× and XR-0.2× (n = 20; within-participant robust z scores, mean of tasks). Lines are colored by which XR mode the participant ranked higher; the black line shows the mean. Phasic area was lower in in XR-0.2× for 20 of 20 participants.

Figure 9.
Each participant’s mean RMSSD in XR-1× and XR-0.2× (n = 20; within-participant robust z scores, mean of tasks). Lines are colored by which XR mode the participant ranked higher; the black line shows the mean. RMSSD was lower in XR-0.2× for 15 of 20 participants.
Figure 9.
Each participant’s mean RMSSD in XR-1× and XR-0.2× (n = 20; within-participant robust z scores, mean of tasks). Lines are colored by which XR mode the participant ranked higher; the black line shows the mean. RMSSD was lower in XR-0.2× for 15 of 20 participants.

Table 1.
Human factors and measurement methods reported in eight recent reviews of HRI evaluation. N: primary studies in the review; other numbers indicate the counts of primary studies reported by each review for the corresponding method. Eye tracking (reported in [n] of the eight reviews) is not shown, as it is a behavioural rather than a physiological measure. –: not reported or no counts given.
Table 1.
Human factors and measurement methods reported in eight recent reviews of HRI evaluation. N: primary studies in the review; other numbers indicate the counts of primary studies reported by each review for the corresponding method. Eye tracking (reported in [n] of the eight reviews) is not shown, as it is a behavioural rather than a physiological measure. –: not reported or no counts given.
| Review | Type | N | Most frequently reported factors | Questionnaires | Physiological measures | Participants’ own comments |
| Hopko et al. (2022) | Systematic | 61 | Trust, workload, stress, perceived safety | 42 | EDA 7, ECG 5, EMG 5, FMG 8, EEG 1 | Interviews 7, think-aloud 2 |
| Abdulazeem and Hu (2023) | Narrative | 162 | Robot perception, emotions, physical comfort, workload | 72 | Physiological signals 23 | – |
| Apraiz et al. (2023) | Systematic | 24 | Workload, perceived safety, usability, trust | 15 | HRV 2 | – |
| De Nobile et al. (2024) | Systematic | 76 | Workload, stress, trust, emotions | 62 | ECG 15, EDA 11, EEG 8, muscular 12 | – |
| Liu et al. (2024) | Scoping | 46 | Workload, trust, human ability, acceptance | 33 | HRV 6, EEG 4, EDA 2, muscular 1 | Interviews 3 |
| Yahia et al. (2024) | Systematic | 15 | Workload, usability, stress, trust | 15 | EEG 2, EDA 2, ECG 2 | – |
| Ricci et al. (2025) | Narrative | 20 | Workload, trust, stress | – | EEG 11, EDA 4, ECG 3 | – |
| Sarvghadi et al. (2025) | Survey | 24 | Trust, workload, stress, fatigue | – | EDA 20, HRV 17, EEG 8, skin temperature 8, EMG 5, other | – |
Table 2.
The two XR modes compared on the predefined measures and in the preference ranking (N = 21). On the predefined measures they were equivalent or inconclusive; in the preference ranking they differed.
Table 2.
The two XR modes compared on the predefined measures and in the preference ranking (N = 21). On the predefined measures they were equivalent or inconclusive; in the preference ranking they differed.
| Measure | XR-1× | XR-0.2× | Difference [CI] | Test, p | Result |
| A. Predefined measures | M (SD) | M (SD) | dz [90% CI] | Equivalence | |
| Usability | 15.02 (3.78) | 15.12 (3.65) | −0.07 [−0.44, 0.31] | 0.031 | Equivalent |
| Workload | 15.40 (3.71) | 15.17 (3.66) | 0.11 [−0.27, 0.49] | 0.045 | Equivalent |
| Agency | 13.60 (4.96) | 14.02 (4.68) | −0.13 [−0.51, 0.25] | 0.053 | Inconclusive |
| Attempts | 1.70 (1.02) | 1.65 (1.08) | 0.06 [−0.32, 0.44] | 0.029 | Equivalent |
| Errors | 1.63 (1.65) | 1.37 (1.63) | 0.22 [−0.15, 0.60] | 0.111 | Inconclusive |
| B. Comparative judgment | |||||
| Preference ranking | Ranked higher by 16 | Ranked higher by 5 | 76% [95% CI 53–92%] | Sign test, 0.027 | Differs: XR-1× preferred |
| C. Manipulation check | M (SD) | M (SD) | dz [90% CI] | ||
| Completion time (s) | 67.83 (35.79) | 122.83 (47.17) | −1.60 [−1.98, −1.23] | – | Longer in XR-0.2× by design |
dz: standardized paired difference, XR-1× minus XR-0.2×. Equivalence: the larger p of the two one-sided tests against ±0.5 dz; below 0.05, the 90% CI lies within the bounds and the two modes are equivalent. Sign test: exact two-sided test of the 16 to 5 split against an even split; 76% is the proportion of participants who ranked XR-1× higher, with its exact 95% CI. Questionnaire scores are means of items on the 21-point scale, coded so that higher values are more favorable (for workload, lower workload). Attempts and errors are means per task. Flow and trust were not tested because of their low internal consistency (α = 0.32 and 0.58). Results for KT are given in the text.
Table 3.
Descriptive and inferential statistics for EDA features across interaction modes (within-participant robust z scores; M ± SD of participant means; n = 20).
Table 3.
Descriptive and inferential statistics for EDA features across interaction modes (within-participant robust z scores; M ± SD of participant means; n = 20).
| Feature | KT | XR-1× | XR-0.2× | F(2,38) | p | Adj. p | η2p |
| SCL mean | −1.14 ± 3.25 | −0.04 ± 0.76 | −0.02 ± 1.87 | 1.64 | 0.207 | 0.620 | 0.08 |
| SCL slope | 0.24 ± 0.76 | 0.55 ± 2.75 | 0.09 ± 0.89 | 0.31 | 0.736 | 1.000 | 0.02 |
| SCR rate (per min) | 0.40 ± 0.50 | 0.41 ± 0.63 | −0.93 ± 0.63 | 30.89 | <0.001 | <0.001 | 0.62 |
| SCR amplitude | −0.25 ± 0.85 | 0.36 ± 0.94 | −0.09 ± 0.80 | 2.08 | 0.139 | 0.555 | 0.10 |
| Phasic area (per min) | −0.07 ± 0.23 | 2.02 ± 1.74 | −0.41 ± 1.34 | 29.72 | <0.001 | <0.001 | 0.61 |
Values are means of each participant’s three tasks. Adj. p: Holm adjustment across the seven physiological features (five EDA and two HRV features).
Table 4.
Post hoc contrasts for the phasic EDA features across interaction modes (Holm-corrected; n = 20).
Table 4.
Post hoc contrasts for the phasic EDA features across interaction modes (Holm-corrected; n = 20).
| Feature | Contrast | t(19) | p(Holm) | dz | Interpretation |
| SCR rate | XR-1× − KT | 0.06 | 0.953 | 0.01 | XR-1× ≈ KT |
| SCR rate | XR-0.2× − KT | −7.67 | <0.001 | −1.72 | XR-0.2× < KT |
| SCR rate | XR-0.2× − XR-1× | −6.35 | <0.001 | −1.42 | XR-0.2× < XR-1× |
| Phasic area | XR-1× − KT | 5.09 | <0.001 | 1.14 | XR-1× > KT |
| Phasic area | XR-0.2× − KT | −1.10 | 0.285 | −0.25 | XR-0.2× ≈ KT |
| Phasic area | XR-0.2× − XR-1× | −8.26 | <0.001 | −1.85 | XR-0.2× < XR-1× |
Table 5.
Descriptive and inferential statistics for HRV time-domain features across interaction modes (within-participant robust z scores; M ± SD of participant means; n = 20).
Table 5.
Descriptive and inferential statistics for HRV time-domain features across interaction modes (within-participant robust z scores; M ± SD of participant means; n = 20).
| Feature | KT | XR-1× | XR-0.2× | F(2,38) | p | Adj. p | η2p |
| SDNN | 0.92 ± 4.90 | 0.17 ± 1.30 | −0.19 ± 1.45 | 0.68 | 0.513 | 1.000 | 0.03 |
| RMSSD | −0.24 ± 1.95 | 0.88 ± 1.28 | −0.23 ± 1.47 | 3.24 | 0.050 | 0.251 | 0.15 |
Values are means of each participant’s three tasks. Adj. p: Holm adjustment across the seven physiological features. CV was not analyzed (Section 3.6.2).
Table 6.
Post hoc contrasts for RMSSD across interaction modes (Holm-corrected within RMSSD; n = 20).
Table 6.
Post hoc contrasts for RMSSD across interaction modes (Holm-corrected within RMSSD; n = 20).
| Feature | Contrast | t(19) | p(Holm) | dz | Interpretation |
| RMSSD | XR-1× − KT | 2.35 | 0.060 | 0.52 | XR-1× ≈ KT |
| RMSSD | XR-0.2× − KT | 0.00 | 0.999 | 0.00 | XR-0.2× ≈ KT |
| RMSSD | XR-0.2× − XR-1× | −2.72 | 0.041 | −0.61 | XR-0.2× < XR-1× (trend) |
Because the RMSSD mode effect did not survive adjustment across features, these contrasts are descriptive only (Section 3.6.2).
Table 7.
Codebook and number of participants whose comment contained each code: all participants, and by which XR mode they ranked higher (group sizes in parentheses).
Table 7.
Codebook and number of participants whose comment contained each code: all participants, and by which XR mode they ranked higher (group sizes in parentheses).
| Code | Definition | Example | All (21) | XR-1× (16) | XR-0.2× (5) |
| Replay speed: favoring full-speed replay | |||||
| R1 Slow replay too slow, annoying, or boring | The slow replay is described negatively because of its pace | “Safety speed was a little too slow, it was boring to wait for the robot to finish the trace” (P04F) | 7 | 6 | 1 |
| R1b Of which “bored” or “boring” | An R1 comment that uses the words bored or boring | “I get bored while waiting the slower robot controlled with AR” (P03F) | 4 | 4 | 0 |
| R2 Full-speed replay kept one’s own tempo | The full-speed replay matched the speed of the participant’s own movement, or the slow replay did not | “the same speed following my actions was better than the low speed” (P06F) | 3 | 3 | 0 |
| R3 Full-speed replay enjoyable or smooth | Enjoyment or smoothness attributed to the full-speed replay | “I really enjoyed the same speed” (P10M) | 3 | 3 | 0 |
| R4 Full-speed replay took less time | Shorter execution named as an advantage | “it takes less to execute” (P07M) | 1 | 1 | 0 |
| R5 Slow replay less accurate | The slow replay followed the path less accurately than the full-speed replay | “This one is by far the most that robot didn’t follow my instructions clearly” (P10F) | 1 | 1 | 0 |
| Replay speed: favoring slow replay | |||||
| R6 Slow replay safer, more reliable, more accurate, or more controlled | Safety, reliability, accuracy, or control credited to the slow replay, or unease or inaccuracy attributed to the full-speed replay | “Different speed makes it more reliable and secure” (P01M) | 6 | 2 | 4 |
| Replay speed: neither | |||||
| R7 Replay speed made little difference | The participant says that replay speed did not matter | “Speed did not change much for me” (P03M) | 1 | 1 | 0 |
| Any cost of the slow replay’s pace (R1, R2, or R4) | 10 | 9 | 1 | ||
| Any comment on replay speed (R1–R7) | 15 | 11 | 4 | ||
| XR programming in general | |||||
| X1 Easy or low physical effort | XR programming described as easy, easy to learn, or physically undemanding | “The AR part was much more easier than physically moving the robot” (P06F) | 7 | 5 | 2 |
| X2 Hand input, calibration, or path-following problems | Problems with hand tracking, gestures, calibration, or the robot not following the drawn path | “I think calibration of my hand with robot can be improved” (P05M) | 9 | 6 | 3 |
| Kinesthetic teaching | |||||
| K1 Physically demanding or hard to use | KT described as physically demanding, tiring, or hard to control | “It requires high physical strength to move the robot” (P08M) | 17 | 13 | 4 |
| K2 Accurate, reliable, or in control | KT described as precise, reliable, or giving a sense of control | “Manual is good because it goes exactly where you tell it to go” (P04M) | 6 | 4 | 2 |
A comment could carry several codes. Codes for each participant are listed in Appendix A.
Table 8.
Group-level joint display of the five evaluation channels, with one row for each research question.
Table 8.
Group-level joint display of the five evaluation channels, with one row for each research question.
| Research question | Questionnaire | Performance | Preference ranking | Physiology (EDA, HRV) | Open-ended responses | Integration |
| RQ1: physiological differentiation of two modes equivalent on the predefined measures | No: usability and workload equivalent; agency inconclusive | No: attempts equivalent; errors inconclusive; trials longer by design | Yes: 16 of 21 ranked XR-1× higher | Yes: fewer SCRs and less phasic area in XR-0.2× (dz = 1.42, 1.85); RMSSD higher in XR-1× (trend) | Yes: 15 of 21 commented on replay speed; 1 said it made little difference | Confirmation: preference, physiology, comments. Discordance: predefined measures versus the other three channels, apparent (see rows RQ2a and RQ2b) |
| RQ2a: contextualizing the physiological differentiation | Silent: Silent on the cost: no item on waiting, boredom, or tempo. No on the gain: unease about the robot’s speed did not differ | Partly: XR-0.2× trials 81% longer, the extra time spent watching | Silent: the ranking does not say what the difference consisted of | Partly: less phasic activation in XR-0.2×, compatible with understimulation and with reduced threat | Yes: Yes, two readings. Cost (10): too slow, annoying, or boring (7; 4 said bored or boring), out of tempo (3), longer (1). Gain (6): safety, reliability, accuracy, or control | Confirmation: physiology and comments. Expansion: comments give the same change two opposite meanings; performance shows the time spent watching. Silence: questionnaire. Discordance: minor, on annoyance |
| RQ2b: contextualizing the divergence in preference | Silent: no item on safety; trust not interpreted; usability and workload equivalent | Inconclusive: errors, relevant to the accuracy some participants cited | Yes: 16 ranked XR-1× higher, 5 ranked XR-0.2× higher | No: lower phasic activity in XR-0.2× in both preference groups, if anything more in those who preferred it | Yes: pace as a cost (9 of the 16); safety, reliability, accuracy, or control (4 of the 5); accuracy judged differently (2 versus 1) | Confirmation: comments and preference. Expansion: the same bodily change, valued in opposite ways. Silence: questionnaire. Unresolved: accuracy |
Stance of each channel: Yes, it registered the difference or quality in question; No, it addressed it without registering a difference; Partly or Inconclusive; Silent, it did not address it. Integration categories after Fetters et al. [43] (confirmation, expansion, discordance) and O’Cathain et al. [44] (silence). The participant level is reported in Section 4.4.2 and Table A1.
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
Copyright: This open access article is published under a Creative Commons CC BY 4.0 license, which permit the free download, distribution, and reuse, provided that the author and preprint are cited in any reuse.