Spatial, Temporal and Power Consistency in a Reconstructed Electric-Floor Experiment

Submitted:

17 November 2026

Posted:

18 November 2026

You are already at the latest version

Abstract
Surface agreement in a heated floor does not establish the accuracy of internal temperatures. This study reconstructs sixteen operating conditions and twelve pages of measurement bulletins from a 1999 electric-floor experiment. A multilayer Fourier model distinguishes surface averages, cable-adjacent temperatures and inter-cable temperatures; calculations are checked using EES, finite elements and Fluent. Unfitted predictions have mean absolute discrepancies of 0.918 K at the finished surface, 17.379 K beneath a cable and 8.454 K between cables. An observable-specific inversion tests whether heating input alone can reconcile the records. Matching cable-adjacent temperatures requires 1.56–2.70 times nominal power, whereas printed face-flux sums differ from nominal input by at most 1.11%. For a 90 W m-2 condition, the cable-point fit requires 196.4 W m-2 and predicts a surface temperature of 34.26 ◦C against the printed 25.5 ◦C. Thirty upper-insulation records also rise by 1.06–2.33 K over the final labelled three-hour interval. These findings exclude a power-only reconciliation within the specified steady, fixed-property model. The contribution is a reproducible consistency diagnostic linking spatial observations, energy balance and temporal stability; missing contact and time-history information prevents complete experimental validation.
Keywords: 
;  ;  ;  ;  ;  
Copyright: This open access article is published under a Creative Commons CC BY 4.0 license, which permit the free download, distribution, and reuse, provided that the author and preprint are cited in any reuse.