Preprint
Article

This version is not peer-reviewed.

Three-Dimensional End Effects and Measurement-Region Dependence in Electrically Heated Slabs

Submitted:

16 November 2026

Posted:

18 November 2026

You are already at the latest version

Abstract
Finite electric-heating panels are often assessed using transverse temperature profiles, although cable turns can alter whole-surface nonuniformity. This study reconstructs three Kanthal-heated panels from historical photographs, drawings and electrical resistances. Panel widths of 400, 500 and 600 mm correspond to cable pitches of 100, 150 and 200 mm. Three-dimensional multilayer Fourier solutions retain finite serpentine paths and are checked by independent finite-volume and MATLAB calculations. At 70 W m⁻², with adiabatic sides and a drawing-based length of 1.2 m, whole-surface ranges are 5.694, 5.595 and 5.926 K, compared with transverse-model values of 3.779, 3.560 and 3.512 K. P3 retains an almost unchanged mid-length range despite substantial end effects. Excluding 200 mm at each longitudinal end reverses the panel ranking. Twenty-four additional finite-volume cases test assumed lateral coefficients of 0, 2 and 8.3 W m⁻² K⁻¹, with refinement to 11.06 million control volumes. Whole-top variation exceeds mid-length variation throughout; final refinement changes whole-top ranges by less than 0.024 K. The results establish case-specific dependence on geometry, observation region and boundary losses. Historical experimental summaries remain conditional comparisons because sensor selection and boundary conditions are incompletely specified.
Keywords: 
;  ;  ;  ;  ;  
Copyright: This open access article is published under a Creative Commons CC BY 4.0 license, which permit the free download, distribution, and reuse, provided that the author and preprint are cited in any reuse.