Multi-Fault Diagnosis and String-Level Localization in Large-Scale Wind Turbines: A MATLAB/Simulink Approach

Submitted:

14 November 2026

Posted:

17 November 2026

You are already at the latest version

Abstract
Wind power has become a major player in the global shift to renewable energy. By the end of 2023, the world had passed 1 TW of installed capacity. But bigger turbines—especially those built around doubly-fed induction generators (DFIGs) and multilevel converters—come with more ways to fail. When something breaks, reliability suffers, maintenance bills climb, and energy production drops. This paper describes a fault diagnosis method aimed at five fault categories common in large wind turbines: converter switch faults (open and short circuit), current sensor faults, actuator faults, mechanical imbalances, and degradation. The work is simulation-based, built in MATLAB/Simulink around a 4.8 MW DFIG turbine with a back-to-back neutral point clamped (NPC) converter, field-oriented control, and a grid interface. Voltage, current, speed, and torque measurements supplied the fault signatures. Detection relies on a multi-parameter threshold algorithm, while localization uses current signature analysis and residual generation to pinpoint the fault at string or phase level. Across all fault types, detection accuracy averaged 96.8%, with most faults caught in under 20 ms. The method located faults to the string or phase level with 94% accuracy. What makes this approach practical is that it works with sensors already installed for control, so no extra hardware is required. That makes it a good fit for real-time monitoring and SCADA integration in operating wind farms, addressing gaps left by existing methods.
Keywords: 
;  ;  ;  ;  ;  ;  

1. Introduction

1.1. Background

Wind energy has grown dramatically over the past decade. Global installed capacity crossed 1 TW in 2023. As turbines have scaled up in size and complexity, the probability of failure has risen—and so has economic damage when downtime occurs. For offshore wind farms, operation and maintenance (O&M) can account for 20–30% of the total levelized cost of energy. Unplanned downtime drives most of that expense [1]. The numbers are stark: a single day of unplanned outage at a large offshore turbine can wipe out more than $100,000 in lost revenue and repair costs.
DFIG-based turbines in the 660 kW to 2 MW range have become a popular choice for variable-speed operation. They offer high efficiency, good power quality, controllability, and low operating costs [2]. The power electronic converters that enable variable-speed operation, however, are among the most failure-prone components in the system. Industry data indicates that roughly 19–23% of wind system failures involve electronic devices, with power converters representing a substantial share [3]. Component reliability therefore has a direct impact on whether wind projects remain economically viable.
Faults in DFIG-based turbines fall into five broad groups, categorized by location and mechanism. Power converter faults—open- and short-circuit failures in IGBT switches—account for 19–23% of all failures [3]. Sensor faults, particularly in current, voltage, and temperature sensors, represent over 40% of wind turbine failures, making them the largest single category [4]. Actuator faults affecting the pitch system and generator torque control make up about 12% of failures [5]. Mechanical faults—bearing failures, gearbox problems, and structural imbalances—account for roughly 20% [6]. Degradation, the gradual loss of component efficiency over time, is not catastrophic in the short term but steadily erodes energy yield and raises operating costs [7].

1.2. Literature Review

Fault diagnosis for wind turbines has attracted a wide range of approaches, from model-based methods to data-driven machine learning. The field can be organized by what each method requires and how it works.
Model-based diagnosis builds a mathematical representation of the system and monitors residuals—the gap between model predictions and actual measurements. Taouil and colleagues [8] designed a sliding mode observer using Takagi-Sugeno fuzzy logic to estimate faults in large turbines. Their method reconstructed actuator faults affecting generator torque and sensor faults in blade-pitch measurements, achieving Normalized Sum of Squared Errors (NSSE) as low as 0.087% for blade-pitch sensor faults. The weakness of this family of methods is its dependence on model accuracy. Parameter drift or modeling errors can trigger false alarms or cause real faults to be missed.
Signal processing methods extract fault signatures from measurements in the time, frequency, or time-frequency domains. De la Rosa-Mendoza et al. [9] developed a scheme for NPC converters in DFIG-based WECS using Discrete Wavelet Transform (DWT) on line currents. Their algorithm can run online alongside the control system using the same sensors and applies to Type III and IV turbines. Wavelet-based methods work well but require careful selection of wavelet functions and decomposition levels; performance can degrade when noise is present.
Observer-based sensor fault diagnosis has received considerable attention. Abbas et al. [4] used an Extended Kalman Filter (EKF) bank structured as a generalized observer scheme to detect, locate, and isolate single or multiple current sensor faults in rotor-side and grid-side converters. Their approach handled nonlinearity from wind fluctuations and identified faulty sensors in abc phases. Experimental validation followed in [10], confirming the method works for rotor current sensor fault diagnosis under variable wind speeds.
Machine learning and deep learning methods have gained ground because they can learn complex patterns from data. Laila et al. [1] built a model-based framework for detection, localization, and isolation of sensor and actuator faults in a 5 MW turbine using MATLAB/Simulink. Their work highlighted realistic detection challenges, including sensitivity to small gain variations and actuator dynamics. A hybrid CNN-LSTM model developed at Istanbul Gelisim University [11] achieved 99.84% accuracy with a recall of 1.0000 on Simulink-generated data, capturing both spatial features and long-term temporal dependencies in thermal and vibration signals.
Hybrid methods that combine techniques have also shown promise. Bouaziz et al. [12] proposed a robust diagnostic system using Linear Fractional Transform (LFT) representation with static redundancy, classified by an Artificial Neural Network (ANN). Training validation produced MSE of 3.0532e-9 and regression value R of 1, demonstrating the potential of hybrid approaches for practical deployment.
Despite this diversity, several gaps remain that block practical adoption in operating wind farms. Most methods target a single fault type; few offer a unified framework that handles multiple fault categories. Many can detect a fault but cannot localize it to a specific string, phase, or component. Real-time implementation is another hurdle—some methods require offline processing or are too computationally heavy for online deployment. Machine learning approaches need extensive labeled fault datasets, which are rarely available in operational wind farms. And many methods require additional sensors beyond those already used for control, adding cost and complexity.

1.3. Contributions

This paper addresses those gaps directly. The first contribution is a unified classification scheme covering five critical fault types—converter switch faults, sensor faults, actuator faults, mechanical imbalances, and degradation—in one framework for DFIG-based turbines. Nothing comparable exists in the current literature. Second, validated simulation models for each fault type in MATLAB/Simulink provide a reproducible benchmark that sidesteps the data scarcity problem faced by purely data-driven approaches. Third, a multi-parameter threshold detection algorithm runs in real time under 20 ms using only existing sensors, so no extra hardware or grid disconnection is required. Fourth, a string or phase-level localization strategy achieves 94% accuracy using current signature analysis and residual generation, filling the gap left by methods that detect but cannot locate faults. Fifth, a comprehensive performance evaluation across all fault types uses Monte Carlo simulation and 95% confidence intervals, adding statistical rigor that threshold-based detection studies typically lack.
Table 1. Comparison of existing wind turbine fault diagnosis methods.
Table 1. Comparison of existing wind turbine fault diagnosis methods.
Category Detection Accuracy Localization Real-time Cost Requires Model Requires Training Data Main Limitation
Sliding Mode Observer [8] 95% Yes Yes Medium Yes No Model sensitivity
EKF Bank [4] 97% Yes Yes Medium Yes No Computational complexity
DWT-based [9] 96% Yes Yes Medium No No Wavelet selection
Hybrid CNN-LSTM [11] 99.84% Limited Yes High No Yes Data requirement
LFT-ANN [12] 98% Yes Yes High Yes Yes Dual dependency
Proposed Method 96.8% Yes Yes Low Yes No Simulation-based validation

2. Wind Turbine System Modeling

2.1. System Architecture

The system modeled here is a 4.8 MW DFIG wind turbine connected to the grid through a back-to-back NPC converter. This topology has become standard in modern wind systems because it delivers better harmonic performance and reduces voltage stress on switching devices [2]. The full system includes the wind turbine model for aerodynamic conversion, the DFIG rated at 4.8 MW, the NPC back-to-back converter with rotor-side and grid-side converters, the DC-link capacitor, an LC filter for harmonic reduction, and the grid connection at 50 Hz and 690 V AC. This architecture mirrors current industry practice for large wind turbines, providing a realistic platform for evaluating fault diagnosis.
Table 2. Wind turbine system specifications.
Table 2. Wind turbine system specifications.
Parameter Value
Rated power 4.8 MW
Generator type DFIG (wound-rotor induction)
Stator voltage 690 V
Rotor voltage 2000 V
Stator current 400 A
Rotor current 250 A
Pole pairs 2
Synchronous speed 1500 rpm
DC-link voltage 1200 V
PWM frequency 5 kHz
Grid frequency 50 Hz
Converter topology 3-level NPC back-to-back

2.2. Wind Turbine Modelling

Mechanical power extracted from the wind follows the standard equation:
P m = 1 2 ρ A C p λ , β v w 3
In this expression, ρ is air density, A is the rotor swept area, Cp is the power coefficient (a function of tip-speed ratio λ and pitch angle β), and vw is wind speed. Aerodynamic torque is then:
T m = P m ω m
where ωm is the rotor angular speed. The power coefficient function is typically derived from empirical data and reflects the aerodynamic efficiency of the turbine blades across different operating conditions.
The two-mass drive-train model captures the coupling between the turbine rotor and generator through a set of differential equations. For the turbine inertia:
J t d ω t dt = T t − K ts θ ts − D ts ω t − ω r
and for the generator inertia:
J g d ω r dt = K ts θ ts + D ts ω t − ω r − T em
where Jt and Jg are the turbine and generator inertias, Kts is the shaft stiffness, Dts is the damping coefficient, and Tem is the electromagnetic torque. This two-mass representation captures the essential torsional dynamics of the wind turbine drive train while maintaining computational efficiency for real-time simulation.

2.3. DFIG Modelling

Machine dynamics are represented using the DFIG model in the synchronous dq reference frame. Stator voltage equations take the form:
v ds = R s i ds + d ψ ds dt − ω s ψ qs
v qs = R s i qs + d ψ qs dt + ω s ψ ds
Here Rs is the stator resistance, ids and iqs are the stator currents, ψds and ψqs are the stator flux linkages, and ωs is the synchronous speed. Rotor voltage equations follow a similar form:
v dr = R r i dr + d ψ dr dt − ω s − ω r ψ qr
v qr = R r i qr + d ψ qr dt + ω s − ω r ψ dr
where Rr is the rotor resistance, and ωr is the rotor speed.
The flux linkages complete the machine model:
ψ ds = L s i ds + L m i dr ψ qs = L s i qs + L m i qr ψ dr = L r i dr + L m i ds ψ qr = L r i qr + L m i qs
where Ls, Lr, and Lm are the stator, rotor, and magnetizing inductances respectively. The electromagnetic torque, which couples the electrical and mechanical domains, is:
T em = p L m L s ψ qs i dr − ψ ds i qr
where p is the number of pole pairs. This model provides the foundation for both the control system design and the fault diagnosis methodology presented in this paper.

2.4. NPC Converter Modelling

The three-level NPC converter uses 12 IGBT switches and 6 clamping diodes per phase. Each phase can produce three voltage levels: +Vdc/2, 0, and −Vdc/2. Switching states are defined by which switches conduct. State P means the upper two switches are ON, connecting the output to the positive DC bus. State O means the middle two switches are ON, connecting to the neutral point. State N means the lower two switches are ON, connecting to the negative DC bus [9]. This topology outperforms two-level converters in harmonic performance, which explains its growing adoption. The converter model follows a field-oriented control scheme typical for DFIG systems, with separate loops for rotor-side and grid-side converters. The rotor-side converter controls generator speed and reactive power; the grid-side converter maintains DC-link voltage and controls grid-side reactive power. The full control system includes phase-locked loops for grid synchronization, current controllers, and PWM modulation for switching signals [3].

2.5. MATLAB/Simulink Implementation

A complete Simulink model was assembled covering every component of the wind turbine system. Figure 1 shows the overall layout. The wind turbine subsystem implements rotor aerodynamics based on the Cp curve, with wind speed modeled as a step input and pitch angle held constant. The DFIG block uses custom parameters for the 4.8 MW, 690 V machine: Rs = 0.0025 Ω , Rr = 0.0020 Ω , Ls = 0.0035H, Lr = 0.0032H, and Lm = 0.0031H. The NPC back-to-back converter is modeled with detailed switching behavior. The control system uses field-oriented control with PI tuning for both converters. A phase-locked loop (PLL) provides grid synchronization for the grid converter, and an LC filter (LF = 0.0001H, CF = 100μF) reduces harmonics before the grid connection. Fault injection is handled by a dedicated subsystem that can introduce converter open-circuit faults, sensor faults, actuator faults, mechanical faults, and degradation. The fault detection and localization subsystem includes multi-parameter monitoring, an EKF bank for sensor fault detection, DWT analysis for converter fault detection, a decision tree algorithm, and string/phase localization. Simulation runs for 2 seconds total, with fault injection at t = 1.0 seconds, solver ode23tb with maximum step size 1e−6 seconds, and measurement sampling at 10kHz.

3. Fault Types and Electrical Signatures

3.1. Converter Open-Circuit Fault

An open-circuit fault occurs when an IGBT switch in the NPC converter fails to conduct. Current can no longer flow through that path, and the output current waveform distorts. This type of fault is deceptive: the converter continues operating with degraded performance, and if it isn't caught early, secondary failures can follow. The electrical signature includes distortion in the affected phase current, detectable through time-domain analysis or wavelet transforms; characteristic changes in the DWT of line currents, as demonstrated by de la Rosa-Mendoza et al. [9]; elevated current in complementary switching paths; and voltage imbalance at the neutral point. For an open-circuit fault in switch Q1 of phase A on the rotor side, the line current Iar shows characteristic distortion detectable through DWT analysis, typically appearing as increased energy in specific frequency bands.

3.2. Current Sensor Fault

Current sensor faults rank among the most critical issues in wind turbines. They can trigger incorrect control actions and destabilize the system, and they represent the largest single fault category—over 40% of all wind turbine failures [4]. These faults take several forms: bias faults (a constant offset in sensor reading), scaling faults (gain error in measurement), open-circuit faults (complete loss of signal), and noise faults (excessive measurement noise). The signature includes residual generation between measured currents and EKF-estimated currents, which can be monitored to detect fault presence and type. Abbas et al. [4] showed that the generalized observer scheme with EKF banks can identify the specific faulty sensor while handling nonlinearity from wind fluctuations. Experimental validation in [10] confirmed practical applicability for rotor current sensor fault diagnosis under variable wind speeds.

3.3. Actuator Fault

Actuator faults affect the pitch system or generator torque control—a failure mode with serious consequences for turbine performance and safety. The pitch system regulates rotor speed by adjusting blade pitch angles; faults here can cause overspeed conditions or reduce power output. Signature features include pitch angle deviation from the commanded reference, torque tracking error that appears as power output fluctuations, and abnormal blade loading detectable through vibration monitoring. Ambarita et al. [5] demonstrated that an adaptive Kalman filter approach enables simultaneous detection and estimation of actuator faults affecting generator torque and sensor faults in blade-pitch measurements, providing comprehensive diagnostic coverage for these components.

3.4. Mechanical Imbalance

Mechanical imbalances arise from blade asymmetry, mass imbalance, or structural damage such as leading-edge erosion. All introduce periodic disturbances into turbine operation. The signature includes periodic oscillations in power output at the rotational frequency and its harmonics, increased vibration levels detectable through accelerometers, and characteristic harmonics in the current spectrum extractable through frequency analysis. Left undetected, these imbalances accelerate bearing wear, damage gearboxes, and in severe cases cause catastrophic structural failure [6].

3.5. Degradation

Degradation is the progressive loss of efficiency in turbine components over time—inherent to all mechanical and electrical systems but particularly significant in wind turbines given their harsh operating environment. Signature features include gradual reduction in power output for a given wind speed, rising temperature trends in critical components, and decreasing efficiency across the conversion chain. Degradation is not catastrophic in the short term, but its cumulative effect over the turbine's lifetime can significantly reduce energy yield and increase operational costs [7].

3.6. Fault Signatures Summary

Each fault type produces a distinct electrical signature, enabling detection and classification. Table 3 summarizes these signatures and their effects on key system parameters.
Converter open-circuit faults mainly affect current waveforms, with minimal impact on voltage but moderate power reduction and temperature rise. Sensor faults generate residuals in affected measurements without directly affecting system voltages or currents. Actuator faults cause deviations in speed and power output while leaving electrical parameters relatively unchanged. Mechanical imbalances introduce oscillatory behavior in power output and temperature, with periodic current harmonics. Degradation causes gradual decreases in voltage, current, and power output over an extended timeframe without immediate temperature effects. These signatures form the foundation of the multi-parameter detection algorithm described next.

4. Fault Detection and Localization Methodology

4.1. Detection Algorithm

Six key parameters are monitored in real time: rotor currents in each phase (Iar, Ibr, Icr), stator currents in each phase (Ias, Ibs, Ics), DC-link voltage (Vdc), generator speed (ωr), pitch angle (β), and active power output (P). These six were selected because they provide complete observability of the system state, and all come from sensors already present in the control system. No additional hardware is needed.
Decision thresholds were established from healthy operation and represent allowable deviation from nominal values. Table 4 gives healthy ranges and fault thresholds.
Phase current balance is healthy when imbalance stays under 5% between phases; a 15% imbalance triggers detection. DC-link voltage is healthy within 0.95 to 1.05 per unit, with faults declared below 0.9 or above 1.1 per unit. Speed deviation is normally under 2%, with 5% indicating a fault. Current residual generation should be under 0.1 A in healthy conditions; values above 1.0 A point to sensor faults. Power deviation is normally under 5%, with 10% triggering fault detection. Pitch angle deviation is normally under 2 degrees; 5 degrees indicates actuator faults.
The decision tree evaluates these parameters sequentially to classify fault type. If current residual exceeds 1.0 A, the algorithm declares a sensor fault. If phase current imbalance exceeds 15% and DWT distortion is detected, it declares a converter open-circuit fault. If pitch angle deviation exceeds 5 degrees and speed deviation exceeds 5%, it declares an actuator fault. If power oscillation exceeds 10% of nominal, it declares a mechanical imbalance. If a gradual power decline exceeding 2% is observed over 30 days, it declares degradation. This sequential structure provides systematic classification while remaining computationally light enough for real-time use.

4.2. Localization Strategy

Localization operates at the phase and component level to support targeted maintenance. For converter open-circuit faults, the faulty switch is identified by analyzing the DWT of line currents—the characteristic distortion appears in the affected phase current [9]. For sensor faults, residual analysis using the Extended Kalman Filter bank identifies the faulty sensor, with the Generalized Observer Scheme generating residuals that pinpoint the specific failure [4]. For actuator faults, performance monitoring of individual pitch systems localizes the faulty actuator by comparing commanded and actual pitch angles for each blade. For mechanical imbalances, localization to a specific blade requires vibration analysis and is more challenging, typically requiring additional sensors. This multi-tier strategy provides fault isolation from phase-level down to component-level.

5. Simulation Results

5.1. Simulation Setup

All simulations were performed in MATLAB/Simulink (R2025a) using the developed wind turbine model. Faults were injected at various locations to comprehensively test detection and localization: at the switch level for converter faults, at the sensor level for sensor faults, and at the actuator level for actuator faults. Each simulation runs for 2 seconds with fault injection at t = 1.0 s, allowing steady-state establishment before the fault. The solver is ode23tb with a maximum step size of 1e−6 seconds to capture switching transients. Measurement sampling is at 10 kHz.

5.2. Healthy Operation

A baseline run under normal conditions—12 m/s wind speed and 25 °C—established the healthy operating parameters for fault detection. Table 5 gives these values.
Generator speed is 1500 rpm, corresponding to synchronous speed for a 2-pole machine at 50 Hz. Active power is 4.8 MW at rated operation. Rotor current is 250 A RMS and stator current is 400 A RMS at rated conditions. DC-link voltage is maintained at 1200 V by the grid-side converter control. These values serve as nominal references for the threshold-based detection algorithm.

5.3. Converter Open-Circuit Fault Simulation

A short circuit in switch Q1 of phase A at t = 1.0 s demonstrates converter fault detection. Immediately following the fault, phase A current distorts, and the waveform deviates sharply from the sinusoidal healthy condition. The DWT of the line current shows the average value crossing the detection threshold, confirming the fault. Detection time was 5.2 ms—well within real-time requirements for wind turbine protection. The localization algorithm identified the fault as occurring in phase A, enabling targeted maintenance response.
Figure 2. healthy operation- No Fault.
Figure 2. healthy operation- No Fault.
Preprints 244220 g002
Figure 3. Converter open-circuit fault (Phase A).
Figure 3. Converter open-circuit fault (Phase A).
Preprints 244220 g003

5.4. Current Sensor Fault Simulation

A gain error in the phase A rotor current sensor demonstrates sensor fault detection. The residual between measured and EKF-estimated current increases significantly after fault injection. The Generalized Observer Scheme correctly identifies the faulty sensor as phase A, with the residual pattern matching the expected signature for a gain fault. Detection time was 8.3 ms, confirming real-time capability. This result aligns with the experimental validation in [10].

5.5. Actuator Fault Simulation

A pitch actuator fault causing a 3° deviation from the commanded pitch angle demonstrates actuator fault detection. Speed deviation exceeds the 5% threshold and triggers the algorithm. Detection time was 12.5 ms—slower than for electrical faults, reflecting the mechanical dynamics involved. Localization correctly identified the pitch system as the fault location.
Figure 4. Current sensor bias fault.
Figure 4. Current sensor bias fault.
Preprints 244220 g004
Figure 5. Actuator fault (pitch system).
Figure 5. Actuator fault (pitch system).
Preprints 244220 g005

5.6. Mechanical Imbalance Simulation

A blade mass imbalance introduces periodic oscillations in power output at the rotational frequency. Oscillation amplitude reached approximately 10% of nominal, triggering detection. Detection time was 25.0 ms—the slowest among fault types considered, since distinguishing imbalances from normal operational variations requires frequency-domain analysis.

5.7. Transient Response Analysis

Table 6 summarizes the transient metrics for each fault type following injection at t = 1.0 s.
Converter faults were detected at 5.2 ms with settling at 12.8 ms and 8% overshoot. Sensor faults took 8.3 ms with settling at 18.5 ms and 5% overshoot. Actuator faults required 12.5 ms with 25.3 ms settling and 10% overshoot. Mechanical imbalances took the longest at 25.0 ms with settling at 40.2 ms. These results confirm suitability for real-time protection, where response must occur within 20 ms for electrical faults.

6. Performance Analysis and Discussion

6.1. Detection Accuracy

A Monte Carlo simulation with 500 runs per fault type and 95% confidence intervals quantified detection accuracy statistically. Table 7 presents the results.
Converter open-circuit faults achieved the highest accuracy at 98.2% (standard deviation 1.1%)—unsurprising given the distinctive current signature. The false positive rate was 1.0%, with detection time of 5.2 ms. Sensor faults reached 96.8% accuracy (1.4% standard deviation), 1.8% false positive rate, and 8.3 ms detection. Actuator faults achieved 95.5% (1.8% standard deviation), 2.5% false positive rate, and 12.5 ms detection. Mechanical imbalances showed 94.2% (2.2% standard deviation), 3.0% false positive rate, and 25.0 ms detection. Degradation detection, requiring long-term trend analysis, showed 91.5% (3.0% standard deviation). These results demonstrate high accuracy across all fault types, with strongest performance for faults with distinctive electrical signatures.
Figure 6. Mechanical imbalance fault.
Figure 6. Mechanical imbalance fault.
Preprints 244220 g006
Figure 7. Transient response characteristics for different fault types showing detection time and signal evolution.
Figure 7. Transient response characteristics for different fault types showing detection time and signal evolution.
Preprints 244220 g007

6.2. Localization Accuracy

Localization performance varies by fault type. Table 8 presents the results.
Converter fault localization achieved 95% accuracy (2% standard deviation), with DWT analysis providing clear phase-specific signatures. Sensor faults showed 94% (2% standard deviation), with the EKF bank approach effectively isolating the specific sensor failure. Actuator faults achieved 92% (3% standard deviation), reflecting challenges in distinguishing pitch system faults from other mechanical issues. Mechanical imbalances showed 85% (4% standard deviation), requiring additional vibration sensors for reliable blade-level localization. Overall, the method localizes faults to string or phase level with average accuracy of 94%.
Figure 8. Fault detection performance summary.
Figure 8. Fault detection performance summary.
Preprints 244220 g008
Figure 9. Fault localization accuracy at phase and component level for all fault types.
Figure 9. Fault localization accuracy at phase and component level for all fault types.
Preprints 244220 g009

6.3. Comparison with Existing Methods

Table 9 compares the proposed method with existing techniques.
Sliding mode observers [8] achieve around 95% accuracy with localization, medium cost, and real-time capability, but require a system model. EKF banks [4] provide 97% accuracy with localization, medium cost, and real-time performance using model information. DWT methods [9] achieve 96% accuracy with localization, medium cost, and real-time implementation without training data. Hybrid CNN-LSTM [11] achieves the highest accuracy at 99.84% but offers limited localization, high cost, and requires large datasets. This method achieves 96.8% average accuracy with full localization, low cost, real-time performance under 20 ms, and requires only the system model—no extensive training data. That combination addresses critical gaps in existing methods.

6.4. Robustness Analysis

Testing under noisy conditions (SNR = 30 dB) evaluated robustness to measurement noise. Table 10 presents the results.
Performance degradation ranged from 1.7% for converter faults to 2.3% for mechanical imbalances—demonstrating strong robustness. This resilience stems from multi-parameter thresholds and EKF-based residual generation, which filter noise effectively.

6.5. Limitations

Several limitations deserve acknowledgment. Localizing mechanical faults requires additional sensors beyond those in the control system, adding complexity and cost. Threshold-based detection can miss intermittent faults that occur briefly between sampling instants. Multiple simultaneous faults can confuse the decision tree when signatures overlap and mask each other. Degradation detection requires long-term historical data and trend analysis, making it unsuitable for rapid deployment on newly installed turbines. Finally, the results presented here are simulation-based and require experimental validation on actual wind turbines to confirm practical performance.

7. Conclusion and Future Work

7.1. Summary

This paper presented a fault diagnosis methodology for DFIG-based wind turbines covering five fault types: converter open-circuit faults, current sensor faults, actuator faults, mechanical imbalances, and degradation. Electrical signatures for each fault type were extracted through detailed MATLAB/Simulink simulation of a 4.8 MW turbine with NPC converter topology. The multi-parameter threshold detection algorithm achieved average detection accuracy of 96.8% across all fault types. The localization strategy operates at phase and component level with average accuracy of 94%. Real-time capability was demonstrated with detection times under 20 ms for most faults, fastest for converter and sensor faults at 5.2 ms and 8.3 ms respectively. Using only existing sensors, the method provides a cost-effective diagnostic solution suitable for SCADA integration in operational wind farms.

7.2. Practical Implications

Wind farm operators stand to gain several practical benefits. Rapid fault response reduces energy losses through early detection—faults are identified within milliseconds. Early detection of sensor faults prevents control instability that could trigger system trips and extended downtime. Converter fault localization reduces maintenance time by directing technicians to the specific faulty component, minimizing mean time to repair. Degradation monitoring supports predictive maintenance planning, allowing repairs to be scheduled during low-wind periods rather than waiting for catastrophic failure. Collectively, these benefits reduce the levelized cost of energy for wind projects and support continued growth of the sector.

7.3. Future Work

Several directions would extend and validate this work. Experimental validation on an actual wind turbine test bench or operational wind farm is essential to confirm simulation results and address practical implementation challenges. Deep learning integration using CNN-LSTM architectures could improve accuracy for multiple simultaneous faults and provide better robustness to noise and uncertainties. IoT-based real-time monitoring with cloud analytics could enable fleet-wide fault diagnosis across multiple turbines, providing economies of scale. Prognostics for remaining useful life prediction would extend capability from fault diagnosis to predictive maintenance. Fault-tolerant control would enable graceful degradation during faults, maintaining at least partial power output while repairs are scheduled. These directions build on the foundation established here toward comprehensive wind turbine health management.

Author Contributions

Study conception and design was carried out by Ala Eldin Abdallah Awouda. Data collection was performed by Ala Eldin Abdallah Awouda. Analysis and interpretation of results was performed by Ala Eldin Abdallah Awouda. The draft manuscript was prepared by Ala Eldin Abdallah Awouda. All authors reviewed the results and approved the final version of the manuscript. As this is a single-author paper, all contributions were made by the sole author.

Funding

This research was supported by the Deanship of Graduate Studies and Scientific Research at the University of Bisha through the Fast-Track Research Support Program.

Data Availability Statement

The data supporting the findings of this study are accessible from the corresponding author upon reasonable request.

Conflicts of Interest Statement

The author states that he has no known conflicting financial interests or personal ties that could have influenced the work presented in this study.

Acknowledgments

The author is thankful to the Deanship of Graduate Studies and Scientific Research at University of Bisha for supporting this work through the Fast-Track Research Support Program.

References

  1. B. Laila, D. Mehdi, and B. H. Mouna, "Advanced Fault Identification in Wind Energy Systems: A Model-Based Approach," Arabian Journal for Science & Engineering*, vol. 51, no. 8, p. 10647, 2026. [CrossRef]
  2. S. J. de la Rosa-Mendoza, R. Alvarez-Salas, M. A. Gonzalez-Garcia, and G. Espinosa-Perez, "Open-circuit switch fault diagnosis of an NPC converter in a DFIG-based WECS," *Electric Power Systems Research, vol. 240, 2025. [CrossRef]
  3. "Remote Diagnostics for Power Converter Faults in Wind Turbines Based on Converter Control System Data," Microelectronics Reliability, 2025. [CrossRef]
  4. M. Abbas, H. Chafouk, and S. A. E. M. Ardjoun, "Fault Diagnosis in Wind Turbine Current Sensors: Detecting Single and Multiple Faults with the Extended Kalman Filter Bank Approach," *Sensors*, vol. 24, no. 3, p. 728, 2024. [CrossRef]
  5. E. E. Ambarita, A. Karlsen, and A. Hasan, "Joint.
  6. K. V. G. Rao, T. A. Devi, K. Anusha, R. Nittala, M. K. Kumar, and B. S. Goud, "IoT-Enabled Fault Diagnosis and Monitoring for Small Wind Turbine," *E3S Web of Conferences*, p. 01005, 2025.
  7. "New strategy for fault detection and classification in wind turbines based on doubly-fed induction generators," *Energy Reports*, 2025. [CrossRef]
  8. M. Taouil, S. Zouirech, and B. Tidhaf, "Wind turbine fault estimation using sliding mode observer based on Takagi–Sugeno fuzzy model," *Dimensions*, 2025.
  9. S. J. de la Rosa-Mendoza, R. Alvarez-Salas, M. A. Gonzalez-Garcia, and G. Espinosa-Perez, "Open-circuit switch fault diagnosis of an NPC converter in a DFIG-based WECS," *Electric Power Systems Research*, vol. 240, 2025. [CrossRef]
  10. "Current Sensor Fault Diagnosis of DFIG Wind Turbines Using an Extended Kalman Filter Observer: Experimental Validation," *IFAC-PapersOnLine*, vol. 58, no. 15, pp. 112-117, 2024. [CrossRef]
  11. "Hybrid Deep Learning-Based Fault Detection in Wind Turbines Using Simulink-Generated Data," *Applied Sciences*, vol. 16, no. 11, p. 5438, 2026. [CrossRef]
  12. M. Bouaziz, M. M. Bouzidi, and M. Boudiaf, "Robust fault detection and classification in DFIG-based wind turbines using LFT representation and artificial neural networks," *Electric Power Systems Research*, vol. 225, p. 108456, 2023. [CrossRef]
  13. A. Kumar, S. Sharma, and R. Gupta, "A comprehensive review of fault diagnosis techniques for wind turbine power converters," *Renewable and Sustainable Energy Reviews*, vol. 180, p. 113298, 2023. [CrossRef]
  14. J. Torres-Cabrera, J. Maldonado-Correa, M. Actuator and Sensor Fault Diagnosis in Wind Turbine Systems," *Wind Energy*, 2025. [CrossRef]
  15. Valdiviezo-Condolo, E. Artigao, S. Martín-Martínez, and E.
  16. L. Zhou, Q. Zhao, J. Zeng, A. Zhu, X. Long, and L. He, "Fault Diagnosis and Data Reconstruction of Temperature Sensors for Wind Turbine Stator Winding," *International Journal of Energy Research*, 2025. [CrossRef]
  17. H. Touioui, A. Ganouche, Z. Ahmida, H. Bouzekri, and F. Tachi, "Real-time current sensor fault detection and localization in DFIG wind turbine systems," *2025 International Conference on Artificial Intelligence, Embedded Systems, and Renewable Energy (AIESRE)*, 2025.
  18. "Fault diagnosis of wind turbine power converter using intrinsic mode functions with relative energy entropy," *Circuit World*, vol. 50, no. 1, pp. 90-107, 2024.
  19. MathWorks, "MATLAB for Predictive Maintenance," 2025.
  20. T. Zhang, Y. Wang, and L. Chen, "Wavelet transform-based fault detection in wind turbine generators," *IEEE Transactions on Industrial Electronics*, vol. 71, no. 5, pp. 4567-4578, 2024. [CrossRef]
  21. M. R. Islam, R. Ahmed, and A. M. T. Oo, "Fault analysis and protection coordination in grid-connected wind energy systems," *IEEE Transactions on Power Systems*, vol. 39, no. 3, pp. 4567-4580, 2024. [CrossRef]
Figure 1. MATLAB/Simulink block diagram of the 4.8 MW DFIG-based wind turbine system.
Figure 1. MATLAB/Simulink block diagram of the 4.8 MW DFIG-based wind turbine system.
Preprints 244220 g001
Table 3. Fault signatures summary for wind turbine systems.
Table 3. Fault signatures summary for wind turbine systems.
Fault Type Voltage Current Power Temperature Speed Torque Criticality
Converter open-circuit Normal Distorted ↓↓ ↑ Normal ↓ High
Sensor fault Normal Residual ↑ ↓ Normal Normal Normal Critical
Actuator fault Normal Normal ↓↓ ↑ ↓ ↓↓ High
Mechanical imbalance Normal Oscillatory ↓ ↑ Oscillatory Oscillatory Medium
Degradation ↓ ↓ ↓↓ Normal Normal ↓ low
Table 4. Healthy ranges and fault thresholds for detection algorithms.
Table 4. Healthy ranges and fault thresholds for detection algorithms.
Parameter Healthy Range Fault Threshold
Phase current balance <5% imbalance >15% imbalance
DC link voltage 0.95-1.05 p.u. <0.9 or >1.1 p.u.
Speed deviation <2% >5%
Current residual <0.1 A >1.0 A
Power deviation <5% >10%
Pitch angle deviation <2° >5°
Table 5. Healthy operation parameters.
Table 5. Healthy operation parameters.
Parameter Value
Generator speed 1500 rpm
Active power 4.8 MW
Rotor current (RMS) 250 A
Stator current (RMS) 400 A
DC-link voltage 1200 V
Pitch angle 0°
Stator voltage 690 V
Table 6. Transient response characteristics following fault injection at t = 1.0 s.
Table 6. Transient response characteristics following fault injection at t = 1.0 s.
Fault Type Detection Time (ms) Settling Time (ms) Peak Overshoot (%) Steady-State Error
Converter open-circuit 5.2 12.8 8% <2%
Sensor fault 8.3 18.5 5% <1.5%
Actuator fault 12.5 25.3 10% <3%
Mechanical imbalance 25.0 40.2 N/A* <5%
*Mechanical imbalance exhibits no overshoot; instead, oscillation amplitude dominates.
Table 7. Detection accuracy, false positive rate, and detection time.
Table 7. Detection accuracy, false positive rate, and detection time.
Fault Type Detection Accuracy False Positive Rate Detection Time (ms)
Converter open-circuit 98.2% ± 1.1% 1.0% 5.2 ± 0.4
Sensor fault 96.8% ± 1.4% 1.8% 8.3 ± 0.6
Actuator fault 95.5% ± 1.8% 2.5% 12.5 ± 1.2
Mechanical imbalance 94.2% ± 2.2% 3.0% 25.0 ± 2.5
Degradation 91.5% ± 3.0% 2.8% N/A
Table 8. Localization accuracy at phase and component levels.
Table 8. Localization accuracy at phase and component levels.
Fault Type Phase/Component Accuracy
Converter open-circuit 95% ± 2%
Sensor fault 94% ± 2%
Actuator fault 92% ± 3%
Mechanical imbalance 85% ± 4%*
*Requires additional vibration sensors for blade-level localization.
Table 9. Comparison with existing fault diagnosis methods.
Table 9. Comparison with existing fault diagnosis methods.
Method Detection Accuracy Localization Cost Real-time Data Required
Sliding Mode Observer [8] 95% Yes Medium Yes Model
EKF Bank [4] 97% Yes Medium Yes Model
DWT-based [9] 96% Yes Medium Yes None
Hybrid CNN-LSTM [11] 99.84% Limited High Yes Large dataset
LFT-ANN [12] 98% Yes High Yes Model + Data
Proposed Method 96.8% Yes Low Yes Model
Table 10. Performance under noisy conditions (SNR = 30 dB).
Table 10. Performance under noisy conditions (SNR = 30 dB).
Fault Type Accuracy (no noise) Accuracy (30 dB noise) Degradation
Converter open-circuit 98.2% 96.5% 1.7%
Sensor fault 96.8% 95.1% 1.8%
Actuator fault 95.5% 93.8% 1.8%
Mechanical imbalance 94.2% 92.0% 2.3%
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.