Preprint
Review

This version is not peer-reviewed.

From Spectroscopic Data to Database Infrastructures: A Review of High-Resolution Molecular Spectroscopy

  † These authors contributed equally to this work.

Submitted:

06 November 2026

Posted:

09 November 2026

You are already at the latest version

Abstract
The production of high-resolution spectroscopic data is growing significantly, making the issue of its storage and dissemination increasingly critical. Numerous databases have been created to meet very specific needs, and it can be difficult to navigate them. As 2026 draws to a close, this article aims to provide an overview of the most commonly used databases in high-resolution spectroscopy. After reviewing spectroscopic parameters and their origins (measurements, effective models, ab initio calculations), we propose a classification of databases into experimental compilations, calculated databases, and hybrid databases, demonstrating that these categories now form a continuum rather than a discrete partition. We discuss the trade-off between accuracy and completeness, the handling of uncertainties, and issues related to data formats and interoperability. Finally, we identify the main challenges facing the community.
Keywords: 
;  ;  ;  

1. Introduction

High-resolution molecular spectroscopy relies on the precise characterization of transitions between the energy levels of molecules. Experimental and theoretical studies conducted over the decades have led to the accumulation of a vast set of spectroscopic data, including, in particular, the positions and intensities of spectral lines, as well as various molecular parameters.
Given the diversity and volume of this data, it has become essential to centralize it and make it available in databases to facilitate its retrieval, analysis, and comparison, while promoting its reuse by the scientific community.
At present, databases play a crucial role in calculating radiative transfer, spectral identification, and model quantification. However, each database is designed by its creators to meet their own specific needs. The resulting ecosystem is therefore vast, and it can be difficult to navigate. There are, of course, projects aimed at standardizing and consolidating all of this data; we will address this topic with the VAMDC in Section 4. Here, however, our goal is to compile a comprehensive list of all molecular spectroscopy databases, detailing their purpose and status.

2. Spectroscopic Data in Dilute Media

Molecular spectroscopic databases are built on line lists, which are lists of molecular transitions, either experimental, theoretical or both. These lists consist in a series of quantities, or line parameters, which characterise each transition. The minimal set of such parameters consists in the line position and intensity. The others are optional and their presence depend on the database, but they are usually necessary to fully specify the transition and to provide more elements to be used in further calculations, like, for instance, radiative transfer modeling of atmospheres. Let us review these different parameters. Concerning the question of units, which may sometimes be complicated, due to different practices, the reader should refer to the book chapter [1] which details this question.

2.1. Fundamental Spectroscopic Parameters

We restrict this description to quantities relevant for high-resolution molecular spectroscopy from the microwave to the near infrared regions, in absorption, emission or Raman scattering.
  • The line position generally expressed in terms of wavenumber (in cm−1) or frequency (in GHz ). Frequency is mostly used for the microwave and THz spectral domains.
  • The line intensity which represents the strength of the transition. This quantity has multiple definitions and may express different but related quantities, like integrated absorption coefficient, integrated cross-section, Einstein A-coefficient… The favorite and most widely-used quantity for absorption spectra is the integrated line cross-section expressed in the so-called “HITRAN unit”, that is cm−1 / ( molecule  cm−2) as defined in the HITRAN database [2]. Concerning Raman scattering spectra, the absolute experimental line intensity is in general extremely difficult, if not impossible, to measure, and the values given are usually relative line strengths (peak area) in an arbitrary unit.
  • The line assignment which consists of a set of quantum numbers characterising the initial and final quantum states of the considered transition is of great importance to fully and uniquely identify the line. It is also used for some further calculations, like line-mixing effects on the line profile.
  • The lower state wavenumber or energy is a quantity which is used to recalculate the line intensity at a different thermal equilibrium temperature (the line list itself being generally given at 296  K ), using Boltzmann’s law.
  • The line-broadening coefficients are a series of coefficients characterising the pressure effects in diluted gas mixtures containing the considered molecules. Although this is optional and not always measured, it is essential for calculating, for instance, atmospheric opacities. It consists in broadening coefficients and line shift coefficients due to the gas itself (self-broadening) or to foreign perturbers (N2, O2, air, H2, He…) as well as their temperature dependence expressed as a temperature exponent. We provide explanations about these quantities and their use in subsection 2.4.
When possible, it is also good to have uncertainty values for the above quantities. The HITRAN database [2], for instance, provides this in the form of codes that specify the uncertainty range (see the HITRAN 2012 format specifications in Ref. [3]).

2.2. Partition Functions

The correct calculation of line intensities at a specific thermal equilibrium temperature requires the evaluation of the rovibrational partition function Q, also called the Total Internal Partition Sum (TIPS). Its calculation, especially at high temperatures, requires the knowledge of a large number of excited energy levels. These ones can be extrapolated using simple low-order models or even polynomial expressions for very high energies, as shown by Champion et al. [4]. The Dijon group has set-up a specific Web page for the calculation of the CH4 partition function1. TIPS are regularly re-evaluated by Gamache et al. for the HITRAN database, for instance, including newly available energy level data [5].

2.3. The Case of Cross-Sections and Super-Lines

For many molecular systems, especially large polyatomic species, a complete line-by-line description may become impractical due to spectral congestion, storage space and computational cost. In such cases, experimentally measured absorption cross sections provide an alternative representation that remains particularly useful for radiative-transfer applications and atmospheric modeling.
Consequently, some databases, or sections of some databases, provide only such absorption cross-sections, which are integrated absorption intensities over defined bins of wavenumber or frequency. These cross-sections can be either experimental or calculated. They are provided for a given temperature and cannot be recalculated at another one. For instance, the HITRAN database [2] has a cross-section section including several hydrocarbon molecules. The PNNL database [6,7] also includes cross-sections for a large number of molecules; this is now included in the cross-section part of the HITRAN database [2].
In the case of huge calculated line lists that include a very large number of very weak lines, a similar notion that is used is called super-lines. It consists of providing sums of line intensities, viewed as single super-lines, over a grid of temperatures and wavenumbers. This is used for instance in TheoReTS [8,9] and ExoMol [10,11].

2.4. Specific Features of Dilute Media

When dealing with dilute media, either in laboratory experiments (e.g. a gas in a spectroscopic cell) or in a natural environment (e.g. an atmosphere), one should take into account the gas’ physical parameters and the interactions between molecules to correctly reproduce the line profiles or line shapes. This one requires a more or less sophisticated model, depending on the physical and observing conditions.

2.4.1. Line-Shape Models

It is well-known that the effect of the gas temperature broadens individual spectral line giving them a Gaussian shape; this type of line profile only depends on the gas temperature and the molecule’s mass. Thus, it does not require any specific entry in spectroscopic databases. It is, however, usually insufficient in practice, since collisional effects due to the gas pressure also present a strong effect. Pressure alone leads to a Lorentzian line shape. The combination of both temperature and pressure leads to the Voigt line profile, which is the convolution of a Gaussian and a Lorentzian function. However, depending on the specific physical conditions, some more specific effects like Dicke narrowing or speed-dependence may appear and significantly modify the line shape. Various line profile functions have been developed to account for these effects and a recent review is given in a book chapter [12]. The most complete up-to-date of such functions is the so-called Hartmann-Tran Profile (HTP) [13]. A modified version, the mHT profile has been developed recently to account for practical implementation problems [14] and is recommended by the HITRAN database [2].

2.4.2. Importance of Collisional Parameters

The pressure effects can be caused by the gas under consideration itself (e.g. when studying a pure gas in a spectroscopic cell when performing a laboratory experiment) or by one or more foreign perturbers in case of gas mixtures like Earth or planetary atmospheres, for instance. The corresponding self- and/or foreign-broadening parameters (line-broadening γ , line-shift δ and temperature exponents n that reflect the temperature dependence of the previous ones) should be specified for each spectroscopic transition in the databases. As a matter of fact, they may depend on the rovibrational quantum numbers. It is however, a huge task to experimentally measure these parameters; in general, it is not possible to obtain experimental values for all transitions and all possible perturbers. Thus, calculated (from semi-classical [15] or quantum chemistry [16] computations when possible), extrapolated (using for instance simple polynomial approximations derived from a limited set of measured values) or even mean values may be provided. This is often the case since, despite considerable experimental efforts about line broadening measurements, experimental data only exist for a small portion of the spectroscopic transitions. This is also why, as discussed in the previous section, the specification of parameter uncertainties is of great importance. We will come back to the challenge of obtaining accurate collisional data in Subsection 7.2.
Details about these profiles and their database implementation are given in Ref. [1,12,14]. Clearly, the HITRAN database [2] is at present the most advanced one for providing these quantities.

2.4.3. Line-Mixing Effects

Another important effect on spectroscopic absorption profiles which arises when relatively important pressures are implied is the line interference or line-mixing effect. It results from energy exchanges during molecular collisions between closely-lying energy levels implied in different rovibrational transitions, whose quantum numbers should thus be known. Its evaluation requires sophisticated models and calculations as described in a recent review chapter [17]. Data concerning this effect are even more sparse than for isolated line broadening parameters. The HITRAN database [2] provides a line-mixing package dedicated to the CO2 molecule. As a matter of fact, the high CO2 pressure in Venus’ atmosphere renders line-mixing effects very important in this case. For other molecules, these effects are usually included for atmospheric applications by using empirical effective values for the γ air line broadening coefficient.

2.5. Data Sources

The different line parameters described above can be of three different origins. As we explain in the next section, some databases (especially the theoretical ones) use only one type of data, some other mix the different types. It is always very important to read the database documentation to know the origin of the data, since this influences the accuracy and the completeness.
  • Experimental measurements provide the most accurate values and, in principle, the accuracy can be carefully assessed. Nevertheless, it is not possible to accurately record all possible transitions. In particular, very weak and/or blended lines may be difficult to obtain experimentally. One must also keep in mind that the raw spectroscopic data correspond to point-by-point cross-section curves. The spectroscopic parameters should be extracted as secondary data through a data treatment: either a simple peak-fitting procedure if only line positions are required, or more complex line profile fits to extract line intensities and line broadening coefficients. This second case may use a multispectrum fit procedure that requires several spectra recorded at different pressures and/or temperatures. When available, the HITRAN database [2] includes preferably experimental values.
  • Effective Hamiltonian and transition moment models provide a semi-empirical determination of line parameters through a well-known procedure. It requires building parametrized effective Hamiltonian and transition moment (dipole moment or polarizability) operators. An initial approximate set of parameters allows a first spectrum calculation that is compared to the experimental data, leading to the assignment (attribution of quantum numbers) of a set of transitions. Then a non-linear least-squares fit provides new Hamiltonian (from line positions) or transition moment (from line intensities) parameter values that permit a new spectrum simulation. Then the process may be iterated with new assignments and so on. The effective operator parameter sets are generally ill-defined and some values cannot be determined and have to be fixed either to zero or to some theoretical value. It is in this sense that the method is partly empirical. It has been very successful for the study of many molecules [18,19]. It provides calculated line lists with the advantage of completeness, but with a limited extrapolation power outside the experimental measurement range. As a matter of fact, since the method amounts to fit coefficients of polynomial functions, these can quickly diverge when trying calculations for quantum numbers well beyond the values for experimentally assigned lines. In case of complex spectra with many interacting rovibrational bands, the assignment and fit procedure may become very difficult, limiting the accuracy of the results. For too complex spectra implying many very excited levels, this kind of method may become intractable. An example of a database resulting from fit of effective models is CaSDa [20].
  • Ab initioand variational calculations can provide extensive and very complete line lists. Ab initio potential energy and transition moment surfaces are combined with a variational approach to calculate line positions and line intensities (and line broadening parameters can also be obtained using intermolecular potentials, see above). The advantage here is really the completeness. Accuracy can be lower, especially for molecular systems with many atoms, but the computing techniques in this domain progress quite fast. It should be noticed that the accuracy of such methods is usually better for line intensities than for line positions. Several databases provide spectroscopic lines exclusively obtained through such methods, like TheoReTS [8] or ExoMol [10]. They are usually huge databases with up to tens of billions of lines or more.
Some hybrid approaches are also sometimes adopted. The HITRAN [2] database mixes experimental and theoretical values (see below). But it is also possible to use experimental data to correct theoretical line lists. There are two ways to do this. The first one is an a posteriori approach, as illustrated by the MARVEL method [21]. In this case, all existing line assignments found from the literature are collected; through differences, a set of empirical energy levels are extracted and used to recalculate line positions. These line positions are used to replace calculated ones in the database. Of course, this gives accurate data, but only over a partial set of transitions, since there never exist enough experimental data allowing to recover all possible energy levels (see Figure 1). The result is an inhomogeneous line position accuracy across the database, with strong lines more accurate (because better studied experimentally) than the weak ones. Although, this does not allow to correct line intensities, but these ones are usually quite good from quantum chemistry / variational calculations, as stated above.
Another possibility is to use a hybrid variational/effective approach that has been derived recently [22]. This one is more complex. It consists in starting with an ab initio potential energy surface, plus a kinetic energy operator, that is transformed into an effective Hamiltonian by performing contact (perturbative) transformations. This effective Hamiltonian has thus calculated parameters, but some of them can be made adjustable and fitted against experimental data (the interaction parameters, which are crucial to obtain reliable wavefunctions and difficult to determine experimentally being kept fixed to their calculated value). This allows a global improvement of calculated line positions over the whole spectrum. This very promising approach is currently under development.

3. Typology of Spectroscopic Databases

In the field of high-resolution molecular spectroscopy, databases can be classified according to the nature and the homogeneity of their underlying data. Experimental, accuracy-oriented compilations select each parameter from the best available laboratory measurement, and generally provide highly reliable values at the cost of limited spectral coverage. Calculated databases, in contrast, derive every transition from a single theoretical framework. This framework may be an effective Hamiltonian whose parameters are fitted to laboratory spectra, as in the CaSDa databases or the Lille Spectroscopic Database, in which case the accuracy is close to experimental within the range of the fitted data but degrades upon extrapolation; or it may rely on ab initio or variational calculations, which can yield billions of transitions and are designed for completeness rather than accuracy. Finally, hybrid databases combine data of different origins, so that the provenance of the parameters varies from one band, or even one line, to the next. HITRAN, initially a predominantly experimental compilation, has progressively evolved into such a hybrid product, and the JPL and CDMS catalogs for rotational spectroscopy combine model predictions with measured frequencies.
Another possible classification of spectroscopic databases is based on their intended applications. Some databases are primarily designed for atmospheric and remote-sensing applications, where accurate line positions, intensities, and collisional parameters are essential. Others are optimized for astrophysical or exoplanetary studies, which require extremely large and complete line lists capable of describing high-temperature environments. Additional databases are dedicated to laboratory spectroscopy, molecular identification, or plasma diagnostics, where specific spectroscopic features or molecular systems are targeted. Consequently, the structure and content of a database strongly depend on the scientific objectives for which it was developed.

3.1. Experimental and Accuracy-Oriented Databases

The HITRAN project was initiated in the late 1960s by the U.S. Air Force Cambridge Research Laboratories (AFCRL) to address the growing demand for comprehensive data on the infrared properties of the Earth’s atmosphere. This effort emerged during an era marked by the early deployment of satellites and the expansion of atmospheric remote sensing capabilities. Since its first public release in 1973, HITRAN has evolved into a quadrennially updated compilation, now maintained at the Harvard–Smithsonian Center for Astrophysics. The most recent edition, HITRAN2024 [2], provides line-by-line parameters for 60 molecules and their isotopologues (one excluded species is the O atom), complemented by experimental absorption cross-sections for species not yet amenable to a line-by-line representation, collision-induced absorption (CIA) data, aerosol refractive indices, partition sums, and, for the first time, a water-vapour continuum model [23]. A comparable effort was launched in France in 1974 with GEISA (Gestion et Étude des Informations Spectroscopiques Atmosphériques), developed and maintained at the Laboratoire de Météorologie Dynamique [24]. GEISA-2020 archives about 6.7 × 10 6 transitions for 58 molecules (145 isotopologues) between 10−6 and 35877 cm−1, and serves as the reference compilation for several European missions, including IASI, IASI-NG, MicroCarb and MERLIN.
What these compilations share is a philosophy of critical evaluation rather than exhaustiveness: each parameter (line position, intensity, lower-state energy, air- and self-broadened half-width, temperature-dependence exponent and pressure-induced shift) is selected from the best available laboratory measurement or from a semi-empirical calculation that has been benchmarked against experiment, and is accompanied by an uncertainty code and a bibliographic reference. This traceability, however, is only effective if it propagates downstream: in practice, users tend to cite the compilation rather than the original measurements or calculations it relies on, an issue discussed in Section 7.
Dedicated validation procedures, such as the SPARTE (Spectroscopic Parameters And Radiative Transfer Evaluation) algorithm used for GEISA, further assess candidate line lists against atmospheric spectra before inclusion. This accuracy-driven approach is dictated by the requirements of atmospheric radiative transfer and remote sensing, where the retrieval of greenhouse-gas column abundances at the sub-percent level makes spectroscopic uncertainty a leading contributor to the total error budget: a systematic bias of a few percent on line intensities or broadening coefficients propagates directly into retrieved mixing ratios, and hence into trend estimates and flux inversions.
The strengths of these databases therefore lie in the reliability and traceability of their content, in the availability of well-characterized collisional parameters for the atmospherically relevant N2/O2 perturbers (see for example [25]), and increasingly in the support of line-shape models beyond the Voigt profile [13] that are required to reproduce high signal-to-noise laboratory spectra. Their limitations follow from the same design choices. Coverage is incomplete by construction, since transitions are retained on the basis of an intensity threshold tied to detectability in remote-sensing applications rather than to any exhaustive enumeration of the spectrum; the vast number of weak lines and hot bands that become significant at elevated temperatures is largely absent, which leads to a severe underestimation of the opacity above roughly 500–1000 K and motivates dedicated high-temperature compilations such as HITEMP [26]. The obstacle is not merely one of experimental effort: much of the missing opacity resides in a quasi-continuum of individually negligible transitions, whose collective contribution to the absorption in a given spectral region can reach the tens of percent and which no empirical line-by-line model can reproduce [9]. Similarly, collisional parameters remain weighted towards air and self-perturbation. Broadening coefficients, temperature-dependence exponents and, in some cases, shifts induced by H2, He, CO2 and H2O have been progressively introduced since HITRAN2016 [27,28,29], but they cover only a subset of molecules of planetary interest and are largely generated from semi-empirical models constrained by a sparse body of measurements and extrapolated over entire line lists. Their power-law temperature dependence, calibrated near 296 K, offers no guarantee at the 1000–2000 K conditions of hot Jupiters and brown dwarfs, so that applications to H2/He-dominated atmospheres still rely on complementary datasets or approximate scaling relations. These constraints define the domain in which purely ab initio and theoretical line lists, discussed in the next section, become indispensable.
HITRAN itself illustrates that this boundary is no longer sharp. Successive editions have drawn increasingly on calculated data wherever laboratory measurements are absent or insufficient, so that the provenance of the parameters now varies not only from one molecule to the next within a single compilation, but frequently from one band to the next within a given species. Methane is a good example (Figure 2): while the strong bands of the lower polyads are fully assigned and modeled with effective Hamiltonians, a large fraction of the transitions at higher wavenumbers is listed with partial or no quantum assignment, their parameters being retrieved directly from laboratory spectra. These transitions represent 41% of the 12CH4 lines, but only 1.3% of the total intensity at 296 K . However, this does not mean that the data assignments have not been made; rather, it means that the databases are not updated in real time. This is even more true for large hybrid projects like HITRAN (see  Sect. 3.3), which require careful consideration of each decision regarding whether or not to include data. References [8,30,31,32,33,34,35,36,37] are illustrative examples of recent analyses not yet incorporated.
Two cases, chosen among many, illustrate the range. Of the six species newly introduced in HITRAN2024 [2], CH3 lies close to the calculated end: measured intensities being unavailable, its line list rests on variational calculations over ab initio potential energy and dipole moment surfaces, themselves adjusted to the few experimentally determined band centers [38]. H2CO is representative of the numerous intermediate cases, combining empirically determined line positions with computed intensities. What was conceived as a measurement-based compilation has therefore become a hybrid product in practice, and the threefold classification introduced above is best read as a continuum rather than a partition. The implications of this convergence are examined in Section 3.3.
No new edition of the GEISA line-parameter dataset has appeared since GEISA-2020, and dedicated support for its curation has since ended (R. Armante, private communication, 2026). The decision to discontinue development of the GEISA database and its consequences will be discussed in Section 7.

3.2. Calculated Databases

The advent of computer science and its application to molecular spectroscopy in the late 1950s and early 1960s [39,40] paved the way for the development of computer databases. Calculated databases derive every transition from a single theoretical framework, and fall into two families depending on whether this framework is an effective Hamiltonian fitted to laboratory spectra or a set of ab initio or variational calculations.

3.2.1. Effective-Hamiltonian Databases

The Calculated Spectroscopic Databases (CaSDa) developed in Dijon are representative of this category. The current release, CaSDa24 [20], gathers ten independent databases, each dedicated to a single molecule (CH4, CH3Cl, SF6, C2H4, CF4, GeH4, RuO4, SiF4, UF6 and SiH4), whose line lists are computed with the XTDS/SPVIEW software from effective Hamiltonian and transition moment operators expressed in a tensorial formalism and fitted to assigned laboratory spectra. Besides the transitions, they store energy levels and full eigenvector decompositions, so that every line is completely characterized by its quantum numbers, and predictions are not extrapolated far beyond the range of the fitted data. Several HITRAN line lists, such as those of GeH4, C2H4 and SF6, are taken directly from them.
The Lille Spectroscopic Database (LSD) [41] belongs to this category. Although distributed in the same format as the JPL and CDMS catalogs (see Section 3.3), and conceived as a complement to them, it only contains predictions computed from the effective Hamiltonian models fitted by a single group, at the PhLAM laboratory, over the past fifteen years. These data had until then been largely absent from CDMS and JPL and scattered across the supplementary material of individual publications. Its content is dominated by molecules exhibiting large-amplitude motions, such as internal rotation or torsion-inversion, whose spectra require dedicated Hamiltonians (e.g. BELGI [42], RAM36 [43], ERHAM [44] or XIAM [45]) beyond the scope of SPFIT/SPCAT [46]. Predictions can be retrieved with user-selectable frequency and intensity units and temperature, together with the corresponding partition functions, and an application programming interface allows their integration into external analysis and radiative-transfer workflows.

3.2.2. Ab Initio and Variational Line Lists

Theoretical and completeness-oriented databases are essentially based on large-scale ab initio or variational calculations in order to produce exhaustive line lists. Such databases, among which ExoMol and its related variational counterparts constitute typical examples, respond to the pressing need, in astrophysical and exoplanetary contexts, for highly complete spectral coverage, with billions of transitions and applicability at high temperatures. Their main assets reside in their large spectral coverage and their capacity to treat extreme conditions, but one must not overlook their limitations, notably in terms of spectroscopic accuracy, in particular for rovibrational energies and line positions, which can be of variable quality.
It is interesting to note, in this respect, that ExoMol, which was at its origin a purely ab initio project, has progressively evolved towards a hybrid approach, thanks in particular to the integration of experimental data via the MARVEL tool [21,47]. This evolution mirrors that of HITRAN from the opposite direction: a database conceived as purely calculated has become, in practice, a hybrid product, which further supports reading the classification introduced above as a continuum rather than a strict partition. The implications of this convergence are examined in Section 3.3.
The field is evolving rapidly, and new projects are emerging, such as ExomAll [48], which aims to provide a unified, comprehensive database of high-accuracy molecular and atomic spectroscopic data across all wavelengths, including temperature-dependent photodissociation cross-sections and non-LTE data, with on-demand tools for tailored opacity generation and analysis.

3.3. Hybrid Databases

As mentioned earlier, databases originally built on laboratory measurements are increasingly becoming hybrid, in order to take advantage of the best of both approaches: the accuracy of laboratory measurements and the completeness of theoretical line lists, the latter being indispensable at high temperature and in spectral regions where no measurements are available.
The two reference catalogs for radio astronomy, the JPL Molecular Spectroscopy Catalog [49] and the Cologne Database for Molecular Spectroscopy (CDMS) [50,51,52], illustrate a first limited form of hybridization. Their entries are essentially predictions: laboratory transitions (microwave, millimeter, submillimeter, and occasionally far-infrared) are fitted with an effective Hamiltonian, usually with the SPFIT/SPCAT suite [46], and the resulting parameters are used to compute a complete line list up to given quantum number and intensity limits. Two features, however, make them hybrid rather than purely calculated. First, whenever a transition has been measured, its experimental frequency and uncertainty may replace the predicted values, the substitution being flagged in the catalog. Second, each catalog gathers entries contributed by many groups, derived from different data sets, Hamiltonian models and fitting codes, so that the provenance, and hence the reliability, of the predictions varies from one species to the next.
Nevertheless, the term “hybrid” covers very different realities, depending on which quantities (line positions, intensities, line-shape parameters) are taken from experiment and which are computed, and on how the two are combined. Sources may be combined per species, as for GeH4 in HITRAN, taken entirely from GeCaSDa [20], per band, as for methane (Figure 2), or per line, as for H2CO. In practice, existing databases lie on a continuum between two extremes: purely measured line lists, which are accurate but necessarily incomplete, and purely calculated ones, which are complete but whose absolute accuracy is limited.

3.4. Application-Specific Databases

All of these different databases support various projects. Historically, HITRAN was exclusively dedicated to the study of Earth’s atmosphere and the molecules that compose it. That is why, in fact, the line-by-line data are provided for terrestrial isotopic abundances. Then, little by little, the database shifted its focus to molecules with extraterrestrial applications, such as the planets in the solar system, and finally exoplanets.
But some other databases have been developed for very specific applications. For instance, CDSD [53] and S&MPO [54] only target one molecule each, that are CO2 and O3, respectively. Their aim is to be as complete and accurate as possible for these key atmospheric species. CDSD also targets applications to Venus’ atmosphere which is very CO2-rich. PAHdb [55] is dedicated to polycyclic aromatic hydrocarbons for the search of this family of molecules in the interstellar medium, in particular (PAHs being candidates to explain the so-called diffuse interstellar bands, also known as DIBs).

3.5. Summary of Existing Databases

In Table 1, we provide a synthetic overview of the molecular spectroscopy databases that are available as of November 2026, with their main characteristics.
We tried to correctly count species (neutrals and ions) included in each case (but not the isotopologues), which is not an easy task for large databases. For instance, in the case of PAHdb [55], the count of more than 10,000 molecules with many isomers is tricky and we used a Python script for this task. Concerning W@DIS [56], this one was offline at the time of the writing of the present review and we thus used a webarchive version.
We did not mention all these databases in the previous subsections, but we rather only focused on the most commonly used and on the most emblematic examples of each database type. This list aims to be as complete as possible. We have excluded simple compilations that just collect data from other databases, like the Splatalogue2 [57]. The VAMDC portal, which is presented in the next Section, is also not included in this table.

4. Data Infrastructures and Interoperability

4.1. The VAMDC Consortium

The Virtual Atomic and Molecular Data Centre (VAMDC) was developed to link atomic and molecular databases together [66,67]. Rather than a central repository, it is a distributed e-infrastructure: each database remains hosted and curated by its producers, while VAMDC provides a common layer through which these heterogeneous resources can be queried. In practice, each database is connected to this layer through a node, a web service that implements the VAMDC standards described in Section 4.2. Nodes are declared in a central registry, which allows clients to discover them and the queries each one supports, while a species database provides unique identifiers so that the same molecule can be recognized across nodes. The VAMDC project originated from European funding that began in 2009 and ended in 2012, and was subsequently extended for two more years. Although it is no longer supported by its own funds, it continues to operate thanks to the research groups who initiated it. Today, 39 databases, or nodes, are accessible through the portal at the following address: https://portal.vamdc.eu/vamdc_portal/home.seam.
One of VAMDC’s goals is to unify data by providing a single protocol and a versatile, comprehensive file format.

4.2. Standards and Protocols

  • The XSAMS data format (XML Schema for Atomic, Molecular, and Solid Data) is an XML-based data format designed to store and exchange atomic, molecular, particle, and surface interaction (AMPSI) data. It was initially developed under the auspices of the International Atomic Energy Agency (IAEA) and later adapted by the Virtual Atomic and Molecular Data Center (VAMDC) under the name VAMDC-XSAMS.
  • The VAMDC-TAP query protocol is a communication protocol that enables users to query scientific databases dedicated to atomic and molecular physics via the Web in a standardized manner. It is based on the TAP (Table Access Protocol) of the International Virtual Observatory (IVOA), to which it adds rules tailored to atomic and molecular data. Its primary objective is to enable various software programs and researchers to access data from multiple databases without needing to know their internal structure.

4.3. Services and Tools

  • The VAMDC portal is the common entry point for all databases. It is a web interface that allows users to run queries to extract data. (See Section 4.1)
  • The VAMDC Client software is an application that receives the user’s request, queries the registries to determine which data nodes are available, sends the request to each of them, and then aggregates the resulting XSAMS files to provide a unified result.
  • The VALDC Query store records every query sent to the databases and assigns it a unique, persistent identifier, which allows the data to be referenced as it existed at the time of the query. (See Section 7.3)

5. Critical Comparison of Databases

Clearly, there exists no universal molecular spectroscopic database corresponding to any application need. Users should be aware of database contents, accuracy, and data origin. Depending on the exact needs, some choices should be made.

5.1. Accuracy Versus Completeness Trade-Off

As outlined in Section 2 and Section 3 when describing database contents, it appears that accuracy and completeness may be mutually exclusive and the users should be aware of this, depending on the application that is targeted.
By essence, experimental data are generally accurate but not complete, since it is never possible to record all possible molecular transitions under all possible physical (temperature, pressure…) conditions. Effective models producing calculated line lists through fits of molecular parameters using experimental line assignments have limited extrapolation capabilities outside the experimental data range (see subsection 5.2).
Completeness in molecular databases has been made possible quite recently, thanks to the rapid improvement of quantum chemistry methods. These have allowed global calculations over extremely wide wavenumber and temperature ranges. Generally speaking, such purely theoretical data have limited accuracy for line positions (although this improves rapidly, but depends on the molecular size), but very good accuracy for line intensities. At present, such databases are an excellent choice for applications that do not require high-resolution (observation of individual rovibrational lines), but rather reliable band profiles, such as modelling of exoplanetary atmospheres, for instance.
Figure 3 illustrates this topic in the case of C2H2, a molecule for which extensive spectroscopic data exist.

5.2. Validity of Extrapolations (Temperature, Pressure)

All data are given for given wavenumber ranges and for given temperature values or ranges. Extrapolating outside these values is always risky.
It is possible, within some limits, to recalculate line lists at temperatures different from the reference values (usually 296 K) if (i) lower-state energy level positions are given for each transition in order to exploit Boltzmann’s law and (ii) if a sufficient number of hot band lines (for transitions originating from other vibrational states than the ground one) are present in the database. Extrapolation to low temperatures is always possible, subject to the collision parameters. Extrapolation to high temperatures is limited by this number of hot band lines.
Theoretical line lists are calculated within some quantum number ranges which are determined by the experimental data used to produce them. Usually some reasonable extrapolation is made beyond the quantum number range of experimentally assigned lines, but in a limited way. In particular, effective Hamiltonian models are quite restricted in this sense, since they indeed rely on polynomial expressions for line positions, whose coefficients are fitted against experimental line data; thus extrapolating to much higher rotational quantum number values, for instance, may lead to completely wrong values. Figure 4 illustrates this problem with an example for the SiF4 molecule. It also shows that hot band transitions may be missing in the calculated spectrum. Purely ab initio data depend less on this kind of problem since they are more global, as discussed above when dealing with the completeness question.

5.3. Treatment of Uncertainties

Uncertainty values on spectroscopic parameters are absolutely mandatory for applications. Since molecular spectroscopic data are at the core of radiative transfer calculations, their uncertainties are propagated through the atmospheric models, for instance. Assessing and reducing spectroscopic uncertainties is absolutely necessary to lower the resulting uncertainties on concentration, abundance profiles and temperature etc. retrievals.
Line position uncertainties are usually much lower than the intensity ones, since experimental intensities are more difficult to measure experimentally (and line broadening parameter uncertainties are even bigger).
Figure 5 illustrate line position and intensity uncertainties for a small part of the methane spectrum. Of course, weak lines feature bigger uncertainty values, especially for intensities.

5.4. Data Formats and Accessibility

The question of defining a universal format for molecular spectroscopic data is complex. Historically, the VAMDC/XSAMS initiative is the only advanced step towards this aim as it has been discussed in Section 4.
Nevertheless, individual databases often use their own output format. The mostly used format for atmospheric and astrophysical applications is the 160 character HITRAN2012 [3] fixed format. However, from the HITRANonline web site (https://hitran.org), it is now possible to fully customise the output format, as illustrated in Figure 6. This makes the databases very flexible and adaptable to the user’s need.
The Harvard-Smithsonian Center for Astrophysics has also developed HAPI, a Python library that allows users to download data from HITRANonline [70], including non-standard parameters, and then calculate spectra (absorption coefficients, transmittance, radiance) for various line profiles, temperatures, and gas mixtures.
In the microwave and THz regions, the de facto standard is the 80-character .cat format generated by SPCAT [46], which is the native format of the JPL, CDMS and LSD catalogs (see Section 3.3).
ExoMol, for its part, has introduced two main types of files: state files .states and transition files .trans, which describe, respectively, the list of energy levels of the molecule or atom and the possible transitions between energy levels. It should be noted that, for large datasets, .trans files are often split into several parts based on wavenumber ranges.
Converting between all these formats is not easy and therefore requires some caution.

6. Applications of Spectroscopic Databases

Molecular spectroscopic database are at the roots of many applied research domains. Let us just briefly present here some key examples.

6.1. Laboratory Spectroscopy

Although experimental laboratory spectroscopy provide data, it sometimes requires calculated line lists in order to search for lines to measure. This is especially the case for high-precision and ultra-high resolution experimental techniques, such as in the microwave or THz domains, that can only scan very narrow spectral ranges at once. This generally requires a first good estimate of line positions and strength in order to be sure to find the lines and remeasure them with high accuracy. Calculated line lists resulting from global models are usually good sources for this purpose.
Wide-range spectroscopic techniques, such as Fourier-transform infrared (FTIR) spectroscopy also require highly accurate line lists to be used for wavenumber calibration. H2O, CO, CO2 and OCS are generally used for this purpose and taken from the HITRAN database [2] which contains highly accurate data for these common species.

6.2. Atmospheric Modeling and Remote Sensing

Spectroscopy of Earth’s atmosphere and the measurement of its composition was the initial purpose of developing infrared molecular spectroscopic databases starting in the 1970’s, such as HITRAN [2] or GEISA [24]. Nowadays, radiative transfer calculations, concentration measurements of pollutants and other trace species (hydrocarbons, VOC, transient species…), as well as climate predictions using ground-based, balloon and satellite measurements fully rely on such databases (along with other ingredients, such as aerosol absorption and scattering data, for instance) [71,72]. As techniques and instruments constantly evolve, this implies continuous updates and improvements of molecular line lists dedicated to this purpose.

6.3. Astrophysics and Exoplanet Atmospheres

The same techniques are also applied to planetary atmospheres in the Solar System, using telescope and spacecraft data [73]. Venus, Mars, giant planets, Titan and Pluto have all been (and are still) widely studied during the past decades and will be the subject of future investigations. The case of Titan should be mentioned for the complexity of its methane-rich atmospheric chemistry [74]. This has required laboratory-spectroscopic data and thus new database entries, for many organic species. A very important tool for planetary spectroscopy is PSG, Planetary Spectrum Generator3 [75]. This online tool relies on several databases (HITRAN, JPL, CDMS…) to simulate absorption, emission or reflection spectra for most of Solar System Objects and a large variety of observatories, instruments, spacecrafts, for different viewing geometries, etc. However, users should not only use such great tools as black boxes but should be aware that they entirely rely on the underlying molecular spectroscopic data from the different databases. These should continue to be maintained and updated to ensure the reliability and accuracy of the calculations made using them. We discuss this issue in the next section.
Some other astrophysical observations also rely on different spectral ranges. Cometary atmospheres (coma and tail) contain molecular ions and radicals whose spectrum extends into the visible and UV regions. These species and regions are much less studied with fewer existing data, still requiring a lot of laboratory data.
The interstellar medium (and also, to some extent, some upper planetary and stellar atmospheres) contains a lot of molecules at low temperature that are usually identified through their rotational spectrum in the microwave and THz (far-infrared regions). The number of identified molecules, from 2 to 70 atoms is rapidly growing, as shown by Figure 7, also requiring more and more laboratory studies. The JPL [49], CDMS [52] and LSD [41] databases are dedicated to this topic.

6.4. Industrial Applications

Molecular spectroscopic data are also of use in industry. The main uses are quality control (food and pharmaceutical industries) and the detection of impurities, dangerous materials [77] or pollutants [78,79]. It can also be used for health diagnosis, for instance to detect molecules that are characteristic of diabetes in exhaled air [80]. All this requires molecular infrared spectroscopic databases for a variety of compounds.
Another potential, but elusive, application that requires accurate knowledge of infrared line positions is molecular laser isotope separation. Processes have been elaborated for this [81], especially for nuclear industry, but it has never been applied at large-scale.

7. Current Challenges and Perspectives

Given the rapid growth of spectroscopic data (mainly ab initio), the spectroscopy community must address numerous challenges. The following list, while not exhaustive, provides an overview of the main issues it faces, and how we could solve them.

7.1. Inconsistencies Between Databases

As we discussed earlier, there are a multitude of databases, whose design and structural choices depend on the specific needs of their developers and the scientific objectives being pursued. Consequently, there is no universal standardization of the output data: their format, organization, and the available information vary from one database to another. Thus, a database dedicated to experimental microwave observations may serve different purposes than one devoted to infrared (IR) observations, resulting in design choices and output formats specific to each.
It is primarily to address this lack of consistency that the VAMDC proposes an approach aimed at standardizing the exchange of spectroscopic data. Nevertheless, adoption of the XSAMS format remains limited in certain applications, particularly in molecular physics. In fact, many computational codes, particularly those dedicated to radiative transfer, do not directly support this format and rely on pre-existing data formats widely used in the community, such as the HITRAN format. This dependence on formats already integrated into existing tools therefore hinders the adoption of XSAMS in computational workflows.
Furthermore, managing very large volumes of data remains a challenge for the VAMDC, as asynchronous queries, currently under development, are not yet available. This limitation is particularly significant in the case of computed spectroscopic databases, which can contain several hundred billion transitions. Extracting and transferring such large volumes of data therefore poses a major challenge, both in terms of processing time and the computational resources required.
Partial solutions already exist. The VAMDC portal, for example, allows XSAMS results to be converted into HITRAN-format files for a subset of molecules, which facilitates the integration of VAMDC data into existing radiative transfer codes. Extending these conversion tools to all species and other formats commonly used by the scientific community would help remove one of the main obstacles to the adoption of XSAMS.
In terms of data volume, the implementation of asynchronous queries, currently under development, will allow large output files to be prepared on the server side before they are retrieved by the user. These files could also be compressed once generated: thanks to its highly repetitive structure, the XML format generally allows for high compression ratios, which would significantly reduce transfer times and storage requirements. Compression alone, however, does not reduce the cost of generating the files or of analyzing them once they are decompressed; therefore, further development will likely be necessary for the largest lists of calculated lines.
Finally, users should be aware of the different conventions used by each database. For example, as we have already mentioned, HITRAN provides intensities weighted by natural isotopic abundance, unlike ExoMol and CaSDa, for example. Furthermore, the statistical weightings of the nuclear spin differ between HITRAN, ExoMol, and JPL/CDMS, and the intensities are expressed either in line strength S or as the Einstein coefficient A. All of these differences can lead users to make errors when processing data and underscore the need for a standard.

7.2. Lack of Accurate Collisional Parameters

Collisional parameters presented in Subsection 2.4.2 constitute a huge challenge for both experimentalists and theoreticians. Most of the environments described in Section 6, like atmospheres, are gas mixtures. Thus, simulating their absorption spectra requires one to take into account collisions between molecules that broaden the lines. Collisional parameters described in Subsection 2.4.2 are thus necessary for each molecule and for a variety of collisional partners (O2, N2, Air, He, H2, CO2…). As these quantities are difficult and long to measure accurately, this represents a considerable experimental effort, coupled to a huge fitting work to extract the necessary parameters from the experimental data. Clearly, collisional parameters can only be measured for a small portion of the spectrum for a given molecule.
Thus, many collisional parameters in current databases are either extrapolated values, using empirical polynomial formulas to account for rotational quantum number dependence (numerous papers exist that present such empirical extrapolations, see for instance a good example for the CH3Cl molecule in [82]), or simply values from a given rovibrational band that has been measured and which are copied to other unmeasured bands. The second solution ignores a possible vibrational dependence, but this is often the only option available, in the absence of measurements. Figure 8 illustrates this with the case of the air-broadening coefficient for 12CH4 in the HITRAN database [2]. We can clearly distinguish measured values that follow a smooth wavenumber dependence in the case of the main rovibrational bands and extrapolated values forming horizontal lines. The latter values are clearly rough ones that will not provide very accurate results when calculating spectra. This shows how much work is still needed for measuring/calculating γ air coefficients; the situation is even worse for other collisional partners.
Then, collisional parameters can also be calculated using quantum chemistry methods. But this is also a huge task involving large computing resources, since it requires accurate intermolecular potential energy surfaces and dynamical calculations on them. It is likely that, in the near future, AI/deep learning methods may be of considerable help for this topic [83].

7.3. Attribution of Original Data

A less visible but nonetheless important issue concerns the attribution of the data itself. Once a line list, a set of broadening coefficients, or a cross-section is incorporated into a major compilation such as HITRAN, the vast majority of subsequent users cite the compilation rather than the original publications from which these parameters were derived. The bibliographic references associated with each entry remain available, but they are rarely cited in articles that use this data. As a result, the laboratory and theoretical research groups that produce the primary data receive only very limited recognition given their actual impact on atmospheric and astrophysical applications.
Tools that address this issue already exist. Thanks to its Query Store [84,85], VAMDC can assign a DOI to each data extraction, which ensures data traceability and the reproducibility of extractions, and allows for the systematic citation of the authors who originally measured or calculated the data. Similarly, HITRANonline automatically generates a bibliography of original sources for each extraction [86,87]. These approaches are fully in line with the FAIR principles [88], which advocate, among other things, the assignment of persistent identifiers to data and the detailed documentation of their provenance. However, it remains much simpler to cite only the compilation, and there is currently no requirement for users to do otherwise. Encouraging journals to require citation of primary sources, or the DOI of the corresponding extraction, would go a long way toward giving data producers the recognition their work deserves.

7.4. Funding Support Issues

As mentioned earlier, the GEISA database has not been updated since 2020 and its development has been definitely stopped in 2024. And no further updates are planned following the discontinuation of funding. The loss of this redundancy matters because HITRAN and GEISA made independent choices when arbitrating between competing laboratory datasets, and relied on separate validation chains. Discrepancies between the two compilations thus provided an empirical lower bound on the actual uncertainty of the underlying parameters, and repeatedly exposed errors that internal validation alone had missed. With a single curated compilation left standing, such residual systematics become common-mode across all retrieval codes and effectively invisible. The community’s work now rests on a single sustained effort, and therefore on continued support within a single jurisdiction. That support is renewed annually and tied to shifting programmatic priorities, whereas the missions relying on these data are designed to operate for decades.
Generally speaking, funding agencies are reluctant to support work on databases since this is viewed as “incremental research” and not innovative. On the other hand, researchers are reluctant to work on such developments on their research time, since this appears time-consuming with small career valorization. However, we have seen above that many applications crucially depend on high-quality and up-to-date databases and also many data are still missing. Thus, it is absolutely necessary that research funders realize this fact and accept to support such long-term research and service task. Permanent positions in this domain are necessary to ensure continuous maintenance of databases.
Also, mechanisms should be found so that authors of original spectroscopic studies do not disappear behind the databases. In this sense, traceability of data is essential. The VAMDC consortium, in particular, has made efforts in this direction with its portal, by attaching citations to each data, increasing visibility and recognition of experimental and theoretical works behind the databases [89].

8. Conclusion

This review paper intends to provide a rather comprehensive overview of molecular spectroscopic databases at the end of 2026, in order to help users to navigate this rich but complex labyrinth. With the advent of many new and upcoming observational means (instruments, observatories, satellites, spacecrafts…) of both the Earth’s atmosphere and astrophysical objects, there is a rapidly growing need for molecular spectroscopic data. This also implies an increasing demand about the accuracy, completeness and traceability of such data.
It is thus now necessary for molecular spectroscopic databases to switch to a new era, by shifting from a collection of small, dedicated projects developed by single research groups or even individuals, to a more global data system in which reliable data can be found quickly. It is mandatory that such data respect the FAIR (Findable, Accessible, Interoperable and Reusable) principles. The citation of original works should also be facilitated and encouraged. Some efforts have been realized in this direction, as in the case of the VAMDC portal that we have presented, but there is still a lot of work to perform in this domain.
There is thus also a necessity for sustainable database work to be funded by research institutions. Researchers spending a part of their time on this topic should also gain recognition. Spectroscopic databases are so important for many key applications for climate science, astrophysics, industry…, that it has to be considered as such and should not be simply discarded by funding agencies as non-innovative incremental research.

Author Contributions

Conceptualization, C.R. and V.B.; methodology, C.R. and V.B.; software, C.R.; investigation, C.R. and V.B.; data curation, C.R. and V.B.; writing—original draft preparation, C.R. and V.B.; writing—review and editing, C.R. and V.B.; visualization, C.R. and V.B.. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Acknowledgments

The authors thank Dr R. A. Motiyenko and Dr M. Rey for helpful discussions. During the preparation of this manuscript, the authors used Claude (Anthropic, Claude Opus 5.5) for the purposes of counting molecular species in some database catalogs, writing the associated data-retrieval scripts.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Boudon, V.; Richard, C. Quantities and Units in Spectroscopy. In High-Resolution Molecular Spectroscopy 1A; John Wiley & Sons, Ltd, 2026; Volume chapter 1, pp. 1–9. Available online: https://onlinelibrary.wiley.com/doi/pdf/10.1002/. [CrossRef]
  2. Gordon, I.; Rothman, L.; Hargreaves, R.; Gomez, F.; Bertin, T.; Hill, C.; Kochanov, R.; Tan, Y.; Wcisło, P.; Makhnev, V.Y.; et al. The HITRAN2024 molecular spectroscopic database. J. Quant. Spectrosc. Radiat. Transf. 2026, 109807. [Google Scholar] [CrossRef]
  3. Rothman, L.; Gordon, I.; Babikov, Y.; Barbe, A.; Chris Benner, D.; Bernath, P.; Birk, M.; Bizzocchi, L.; Boudon, V.; Brown, L.; et al. The HITRAN2012 molecular spectroscopic database. J. Quant. Spectrosc. Radiat. Transf. HITRAN2012 special issue. 2013, 130, 4–50. [Google Scholar] [CrossRef]
  4. Wenger, C.; Champion, J.; Boudon, V. The partition sum of methane at high temperature. J. Quant. Spectrosc. Radiat. Transf. 2008, 109, 2697–2706. [Google Scholar] [CrossRef]
  5. Gamache, R.R.; Vispoel, B.; Tennyson, J.; Yurchenko, S.N.; Polyansky, O.L.; Gordon, I.E.; Hargreaves, R.J.; Huang, X. Partition sums for molecules and their isotopologues for HITRAN2024. J. Quant. Spectrosc. Radiat. Transf. 2025, 345, 109568. [Google Scholar] [CrossRef]
  6. Sharpe, S.W.; Johnson, T.J.; Sams, R.L.; Chu, P.M.; Rhoderick, G.C.; Johnson, P.A. Gas-Phase Databases for Quantitative Infrared Spectroscopy. Appl. Spectrosc. 2004, 58, 1452–1461. [Google Scholar] [CrossRef] [PubMed]
  7. Johnson, T.J.; Profeta, L.T.; Sams, R.L.; Griffith, D.W.; Yokelson, R.L. An infrared spectral database for detection of gases emitted by biomass burning. Vib. Spectrosc.;Adv. Vib. Spectrosc. (ICAVS 2009) 2010, 53, 97–102. [Google Scholar] [CrossRef]
  8. Rey, M.; Nikitin, A.V.; Campargue, A.; Kassi, S.; Mondelain, D.; Tyuterev, V.G. Ab initio variational predictions for understanding highly congested spectra: rovibrational assignment of 108 new methane sub-bands in the icosad range (6280–7800 cm-1). Phys. Chem. Chem. Phys. 2016, 18, 176–189. [Google Scholar] [CrossRef] [PubMed]
  9. Rey, M.; Nikitin, A.V.; Tyuterev, V.G. Accurate theoretical methane line lists in the infrared up to 3000 K and quasi-continuum absorption/emission modeling for astrophysical applications. Astrophys. J. 2017, 847, 105. [Google Scholar] [CrossRef]
  10. Tennyson, J.; Yurchenko, S.N. ExoMol: molecular line lists for exoplanet and other atmospheres. Mon. Not. R. Astron. Soc. 2012, 425, 21–33. Available online: https://academic.oup.com/mnras/article-pdf/425/1/21/3182616/425-1-21.pdf. [CrossRef]
  11. Yurchenko, Sergei N.; Amundsen, David S.; Tennyson, Jonathan.; Waldmann, Ingo P. A hybrid line list for CH04 and hot methane continuum. A&A 2017, 605, A95. [Google Scholar] [CrossRef] [PubMed]
  12. TRAN, H.; NGO, N.H.; WCISŁO, P. Isolated Line Shape Theory. In High-Resolution Molecular Spectroscopy 1B; John Wiley & Sons, Ltd, 2026; Volume chapter 3, pp. 65–94. Available online: https://onlinelibrary.wiley.com/doi/pdf/10.1002/. [CrossRef]
  13. Ngo, N.; Lisak, D.; Tran, H.; Hartmann, J.M. An isolated line-shape model to go beyond the Voigt profile in spectroscopic databases and radiative transfer codes. J. Quant. Spectrosc. Radiat. Transf. 2013, 129, 89–100. [Google Scholar] [CrossRef]
  14. Wcisło, P.; Stolarczyk, N.; Słowiński, M.; Jóźwiak, H.; Lisak, D.; Ciuryło, R.; Cygan, A.; Schreier, F.; Boone, C.; Castrillo, A.; et al. New beyond-Voigt line-shape profile recommended for the HITRAN database. J. Quant. Spectrosc. Radiat. Transf. 2025, 347, 109596. [Google Scholar] [CrossRef]
  15. GAMACHE, R.R. Semi-Classical Line-shape Theory. In High-Resolution Molecular Spectroscopy 1B; John Wiley & Sons, Ltd, 2026; Volume chapter 4, pp. 95–151. Available online: https://onlinelibrary.wiley.com/doi/pdf/10.1002/9781394474455. [CrossRef]
  16. JÓŹWIAK, H.; WCISŁO, P. Ab Initio Calculations of Line-Shape Parameters. In High-Resolution Molecular Spectroscopy 1B; John Wiley & Sons, Ltd, 2026; Volume chapter 5, pp. 153–198. Available online: https://onlinelibrary.wiley.com/doi/pdf/10.1002/9781394474455.ch5. [CrossRef]
  17. BOULET, C.; TRAN, H. Line Mixing Within and Beyond the Impact Approximation. In High-Resolution Molecular Spectroscopy 1B; John Wiley & Sons, Ltd, 2026; Volume chapter 6, pp. 199–241. Available online: https://onlinelibrary.wiley.com/doi/pdf/10.1002/9781394474455.ch6. [CrossRef]
  18. Papoušek, D.; Aliev, M. Molecular vibrational-rotational spectra; Elsevier: New York, 1982. [Google Scholar]
  19. Boudon, V.; Champion, J.P.; Gabard, T.; Loëte, M.; Rotger, M.; Wenger, C. Spherical Top Theory and Molecular Spectra. In Handbook of High-Resolution Spectroscopy; Quack, M., Merkt, F., Eds.; Wiley: Chichester, West Sussex, United Kingdom, 2011; Vol. 3, pp. 1437–1460. [Google Scholar]
  20. Richard, C.; Fathallah, O.B.; Hardy, P.; Kamel, R.; Merkulova, M.; Rotger, M.; Ulenikov, O.; Boudon, V. CaSDa24: Latest updates to the Dijon calculated spectroscopic databases. J. Quant. Spectrosc. Radiat. Transf. 2024, 327, 109127. [Google Scholar] [CrossRef]
  21. Furtenbacher, T.; Császár, A.G.; Tennyson, J. MARVEL: measured active rotational–vibrational energy levels. J. Mol. Spectrosc. 2007, 245, 115–125. [Google Scholar] [CrossRef]
  22. Rey, M. Novel methodology for systematically constructing global effective models from ab initio-based surfaces: A new insight into high-resolution molecular spectra analysis. J. Chem. Phys. 2022, 156, 224103. [Google Scholar] [CrossRef] [PubMed]
  23. Mlawer, E.; Cady-Pereira, K.; Mascio, J.; Gordon, I. The inclusion of the MT_CKD water vapor continuum model in the HITRAN molecular spectroscopic database. J. Quant. Spectrosc. Radiat. Transf. 2023, 306, 108645. [Google Scholar] [CrossRef]
  24. Delahaye, T.; Armante, R.; Scott, N.; Jacquinet-Husson, N.; Chédin, A.; Crépeau, L.; Crevoisier, C.; Douet, V.; Perrin, A.; Barbe, A.; et al. The 2020 edition of the GEISA spectroscopic database. J. Mol. Spectrosc. 2021, 380, 111510. [Google Scholar] [CrossRef]
  25. Richard, C.; Boudon, V.; Manceron, L.; Vander Auwera, J.; Vinatier, S.; Bézard, B.; Houelle, M. Self and N2 collisional broadening of far-infrared methane lines at low-temperature with application to Titan. Icarus 2023, 404, 115692. [Google Scholar] [CrossRef]
  26. Rothman, L.S.; Gordon, I.; Barber, R.; Dothe, H.; Gamache, R.R.; Goldman, A.; Perevalov, V.; Tashkun, S.; Tennyson, J. HITEMP, the high-temperature molecular spectroscopic database. J. Quant. Spectrosc. Radiat. Transf. 2010, 111, 2139–2150. [Google Scholar] [CrossRef]
  27. Wilzewski, J.S.; Gordon, I.E.; Kochanov, R.V.; Hill, C.; Rothman, L.S. H2, He, and CO2 line-broadening coefficients, pressure shifts and temperature-dependence exponents for the HITRAN database. Part 1: SO2, NH3, HF, HCl, OCS and C2H2. J. Quant. Spectrosc. Radiat. Transf. 2016, 168, 193–206. [Google Scholar]
  28. Tan, Y.; Kochanov, R.; Rothman, L.; Gordon, I. Introduction of water-vapor broadening parameters and their temperature-dependent exponents into the HITRAN database: Part I—CO2, N2O, CO, CH4, O2, NH3, and H2S. J. Geophys. Res. Atmos. 2019, 124, 11580–11594. [Google Scholar] [CrossRef] [PubMed]
  29. Tan, Y.; Skinner, F.M.; Samuels, S.; Hargreaves, R.J.; Hashemi, R.; Gordon, I.E. H2, He, and CO2 Pressure-induced Parameters for the HITRAN Database. II. Line Lists of CO2, N2O, CO, SO2, OH, OCS, H2CO, HCN, PH3, H2S, and GeH4. Astrophys. J. Suppl. Ser. 2022, 262, 40. [Google Scholar] [CrossRef]
  30. Nikitin, A.V.; Rey, M.; Campargue, A.; Tyuterev, V.G. First assignments of the 6ν4, ν2+5ν4, and ν1+4ν4 Triacontad band system of 12CH4 in the 7606–7919 cm-1 region. J. Quant. Spectrosc. Radiat. Transf. 2024, 325, 109098. [Google Scholar] [CrossRef]
  31. Nikitin, A.V.; Rodina, A.A.; Thomas, X.; Manceron, L.; Daumont, L.; Rey, M.; Sung, K.; Protasevich, A.E.; Tashkun, S.A.; Chizhmakova, I.S.; et al. Line list of 12CH4 in the 4300–4600 cm-1 region. J. Quant. Spectrosc. Radiat. Transf. 2020, 253, 107061. [Google Scholar] [CrossRef]
  32. Nikitin, A.V.; Protasevich, A.E.; Rey, M.; Serdyukov, V.I.; Sinitsa, L.N.; Lugovskoy, A.; Tyuterev, V.G. Improved line list of 12CH4 in the 8850–9180 cm-1 region. J. Quant. Spectrosc. Radiat. Transf. 2019, 239, 106646. [Google Scholar] [CrossRef]
  33. Rodina, A.A.; Nikitin, A.V.; Thomas, X.; Manceron, L.; Daumont, L.; Rey, M.; Sung, K.; Tashkun, S.A.; Tyuterev, V.G. Improved line list of 12CH4 in the 3760–4100 cm-1 region. J. Quant. Spectrosc. Radiat. Transf. 2019, 225, 351–362. [Google Scholar] [CrossRef]
  34. Nikitin, A.V.; Thomas, X.; Daumont, L.; Rey, M.; Sung, K.; Toon, G.C.; Smith, M.A.H.; Mantz, A.W.; Protasevich, A.E.; Tashkun, S.A.; et al. Assignment and modelling of 12CH4 spectra in the 5550–5695, 5718–5725 and 5792–5814 cm-1 regions. J. Quant. Spectrosc. Radiat. Transf. 2018, 219, 323–332. [Google Scholar] [CrossRef]
  35. Hjältén, A.; Silva de Oliveira, V.; Silander, I.; Rosina, A.; Rey, M.; Rutkowski, L.; Soboń, G.; Lehmann, K.K.; Foltynowicz, A. Measurement and assignment of J=5 to 9 rotational energy levels in the 9070–9370 cm-1 range of methane using optical frequency comb double-resonance spectroscopy. J. Chem. Phys. 2024, 161, 124311. [Google Scholar] [CrossRef] [PubMed]
  36. Silva de Oliveira, V.; Hjältén, A.; Silander, I.; Rosina, A.; Rey, M.; Lehmann, K.K.; Foltynowicz, A. Combined frequency comb and continuous wave cavity-enhanced optical-optical double-resonance spectrometer in the 1.7 μm range. Opt. Express 2025, 33, 38776–38802. [Google Scholar] [CrossRef] [PubMed]
  37. Lehmann, K.K.; Hjältén, A.; Silander, I.; Rey, M.; Foltynowicz, A. Assignment of collision-induced four-level double-resonance transitions in the 3ν3←ν3 spectral region of methane. J. Chem. Phys. 2025, 163, 144304. [Google Scholar] [CrossRef] [PubMed]
  38. Adam, A.Y.; Yachmenev, A.; Yurchenko, S.N.; Jensen, P. Variationally computed IR line list for the methyl radical CH3. J. Phys. Chem. A 2019, 123, 4755–4763. [Google Scholar] [CrossRef] [PubMed]
  39. Rotenberg, M.; Bivins, R.; Metropolis, N.; Wooten; John K., J. The 3-j and 6-j Symbols; The Technology Press, Massachusetts Institute of Technology: Cambridge, MA, USA, 1959. [Google Scholar]
  40. Brodersen, S.; Richardson, E. Computer analysis of infrared and Raman bands of symmetric top molecules. J. Mol. Spectrosc. 1961, 6, 265–271. [Google Scholar] [CrossRef]
  41. Motiyenko, R.A.; Margulès, L. Lille spectroscopic database for astrophysically and atmospherically relevant molecules. Astron. Astrophys.-A&A 2025, 699, A348. [Google Scholar]
  42. Hougen, J.T.; Kleiner, I.; Godefroid, M. Selection rules and intensity calculations for a Cs asymmetric top molecule containing a methyl group internal rotor. J. Mol. Spectrosc. 1994, 163, 559–586. [Google Scholar] [CrossRef]
  43. Ilyushin, V.V.; Kisiel, Z.; Pszczólkowski, L.; Mäder, H.; Hougen, J.T. A new torsion–rotation fitting program for molecules with a sixfold barrier: Application to the microwave spectrum of toluene. J. Mol. Spectrosc. 2010, 259, 26–38. [Google Scholar] [CrossRef]
  44. Groner, P. Effective rotational Hamiltonian for molecules with internal rotors: Principles, theory, applications and experiences. J. Mol. Spectrosc. 2012, 278, 52–67. [Google Scholar] [CrossRef]
  45. Hartwig, H.; Dreizler, H. The microwave spectrum of trans-2, 3-dimethyloxirane in torsional excited states. Z. Für Naturforschung A 1996, 51, 923–932. [Google Scholar] [CrossRef]
  46. Pickett, H.M. The fitting and prediction of vibration-rotation spectra with spin interactions. J. Mol. Spectrosc. 1991, 148, 371–377. [Google Scholar] [CrossRef]
  47. McKemmish, L.K.; Syme, A.M.; Borsovszky, J.; Yurchenko, S.N.; Tennyson, J.; Furtenbacher, T.; Császár, A.G. An update to the MARVEL data set and ExoMol line list for 12C2. Mon. Not. R. Astron. Soc. 2020, 497, 1081–1097. [Google Scholar] [CrossRef]
  48. ExomAll Consortium. ExomAll: Spectroscopy of exoplanets over the all wavelength. Horizon Europe project, Grant Agreement No. 101267678. Accessed. 2026; (accessed on 2026-11-04). [Google Scholar]
  49. Pickett, H.; Poynter, R.; Cohen, E.; Delitsky, M.; Pearson, J.; Müller, H. Submillimeter, millimeter, and microwave spectral line catalog. J. Quant. Spectrosc. Radiat. Transf. 1998, 60, 883–890. [Google Scholar] [CrossRef]
  50. Müller, H.S.; Thorwirth, S.; Roth, D.; Winnewisser, G. The Cologne database for molecular spectroscopy, CDMS. Astron. Astrophys. 2001, 370, L49–L52. [Google Scholar] [CrossRef]
  51. Müller, H.S.; Schlöder, F.; Stutzki, J.; Winnewisser, G. The Cologne Database for Molecular Spectroscopy, CDMS: a useful tool for astronomers and spectroscopists. J. Mol. Struct. 2005, 742, 215–227. [Google Scholar] [CrossRef]
  52. Endres, C.P.; Schlemmer, S.; Schilke, P.; Stutzki, J.; Müller, H.S. The Cologne Database for Molecular Spectroscopy, CDMS, in the Virtual Atomic and Molecular Data Centre, VAMDC. J. Mol. Spectrosc.;New Vis. Spectrosc. Databases Vol. II 2016, 327, 95–104. [Google Scholar] [CrossRef]
  53. Kochanov, R.; Perevalov, V. CDSD-2024-PI: The update of the CDSD databank for the principal isotopologue of carbon dioxide. J. Quant. Spectrosc. Radiat. Transf. 2025, 341, 109428. [Google Scholar] [CrossRef]
  54. Babikov, Y.L.; Mikhailenko, S.N.; Barbe, A.; Tyuterev, V.G. S&MPO–an information system for ozone spectroscopy on the WEB. J. Quant. Spectrosc. Radiat. Transf. 2014, 145, 169–196. [Google Scholar] [CrossRef]
  55. Ricca, A.; Boersma, C.; Maragkoudakis, A.; Roser, J.; Shannon, M.J.; Allamandola, L.; Bauschlicher, C.W., Jr. The NASA Ames PAH IR Spectroscopic Database: Computational version 4.00, software tools, website, and documentation. Astrophys. J. Suppl. Ser. 2026, 282, 7. [Google Scholar] [CrossRef]
  56. Tennyson, J.; Bernath, P.F.; Brown, L.R.; Campargue, A.; Császár, A.G.; Daumont, L.; Gamache, R.R.; Hodges, J.T.; Naumenko, O.V.; Polyansky, O.L.; et al. IUPAC critical evaluation of the rotational–vibrational spectra of water vapor, Part III: Energy levels and transition wavenumbers for H216O. J. Quant. Spectrosc. Radiat. Transf. 2013, 117, 29–58. [Google Scholar] [CrossRef]
  57. Remijan, A.J.; Markwick-Kemper, A.; et al. Splatalogue: database for astronomical spectroscopy. Proc. Am. Astron. Soc. Meet. Abstr. 2007, Vol. 211, 132–11. [Google Scholar]
  58. Keller-Rudek, H.; Moortgat, G.K.; Sander, R.; Sörensen, R. The MPI-Mainz UV/VIS spectral atlas of gaseous molecules of atmospheric interest. Earth Syst. Sci. Data 2013, 5, 365–373. [Google Scholar] [CrossRef]
  59. Bernath, P.F. MoLLIST: Molecular Line Lists, Intensities and Spectra. J. Quant. Spectrosc. Radiat. Transf. 2020, 240, 106687. [Google Scholar] [CrossRef]
  60. Roueff, E.; Sahal-Bréchot, S.; Dimitrijević, M.S.; Moreau, N.; Abgrall, H. The spectroscopic atomic and molecular databases at the paris observatory. atoms 2020, 8, 36. [Google Scholar] [CrossRef]
  61. Kurucz, R.L. Including all the lines. Can. J. Phys. 2011, 89, 417–428. [Google Scholar]
  62. Ryabchikova, T.; Piskunov, N.; Kurucz, R.; Stempels, H.; Heiter, U.; Pakhomov, Y.; Barklem, P.S. A major upgrade of the VALD database. Physica Scr. 2015, 90, 054005. [Google Scholar] [CrossRef]
  63. Huang, X.; Schwenke, D.; Lee, T. Ames Molecular Spectroscopic Data for Astrophysical and Atmospheric Studies; 2024. [Google Scholar]
  64. Mikhailenko, S.; Babikov, Y.L.; Golovko, V. Information-calculating system spectroscopy of atmospheric gases. The structure and main functions. Atmos. Ocean. Opt. 2005, 18, 685–695. [Google Scholar]
  65. Malloci, G.; Joblin, C.; Mulas, G. On-line database of the spectral properties of polycyclic aromatic hydrocarbons. Chem. Phys. 2007, 332, 353–359. [Google Scholar] [CrossRef]
  66. Dubernet, M.L.; Boudon, V.; Culhane, J.; Dimitrijevic, M.; Fazliev, A.; Joblin, C.; Kupka, F.; Leto, G.; Le Sidaner, P.; Loboda, P.; et al. Virtual atomic and molecular data centre. J. Quant. Spectrosc. Radiat. Transf. 2010, 111, 2151–2159. [Google Scholar] [CrossRef]
  67. Dubernet, M.L.; Antony, B.; Ba, Y.A.; Babikov, Y.L.; Bartschat, K.; Boudon, V.; Braams, B.; Chung, H.K.; Daniel, F.; Delahaye, F.; et al. The virtual atomic and molecular data centre (VAMDC) consortium. J. Phys. B At. Mol. Opt. Phys. 2016, 49, 074003. [Google Scholar] [CrossRef]
  68. Boudon, V.; Manceron, L.; Richard, C. High-resolution spectroscopy and analysis of the ν3, ν4 and 2ν4 bands of SiF4 in natural isotopic abundance. J. Quant. Spectrosc. Radiat. Transf. 2020, 253, 107114. [Google Scholar] [CrossRef]
  69. Rothman, L.; Jacquemart, D.; Barbe, A.; Chris Benner, D.; Birk, M.; Brown, L.; Carleer, M.; Chackerian, C.; Chance, K.; Coudert, L.; et al. The HITRAN 2004 molecular spectroscopic database. J. Quant. Spectrosc. Radiat. Transf. 2005, 96, 139–204. [Google Scholar] [CrossRef]
  70. Kochanov, R.V.; Gordon, I.E.; Rothman, L.S.; Wcisło, P.; Hill, C.; Wilzewski, J.S. HITRAN Application Programming Interface (HAPI): A comprehensive approach to working with spectroscopic data. J. Quant. Spectrosc. Radiat. Transf. 2016, 177, 15–30. [Google Scholar] [CrossRef]
  71. Raychaudhuri, B. Spectroscopic techniques conceptualized with the remote sensing of atmospheric carbon dioxide and other greenhouse gases. Appl. Spectrosc. Rev. 2024, 59, 1344–1372. [Google Scholar] [CrossRef]
  72. Bernath, P.F. Atmospheric Spectroscopy. In Spectra of Atoms and Molecules; Oxford University Press, 2025. [Google Scholar] [CrossRef]
  73. Tinetti, G.; Encrenaz, T.; Coustenis, A. Spectroscopy of planetary atmospheres in our Galaxy. Astron. Astrophys. Rev. 2013, 21, 63. [Google Scholar] [CrossRef]
  74. Nixon, C.A. The Composition and Chemistry of Titan’s Atmosphere. ACS Earth Space Chem. 2024, 8, 406–456. Available online: https://pubs.acs.org/aesccq/article-pdf/8/3/406/3009149/sp2c00041.pdf. [CrossRef] [PubMed]
  75. Villanueva, G.; Smith, M.; Protopapa, S.; Faggi, S.; Mandell, A. Planetary Spectrum Generator: An accurate online radiative transfer suite for atmospheres, comets, small bodies and exoplanets. J. Quant. Spectrosc. Radiat. Transf. 2018, 217, 86–104. [Google Scholar] [CrossRef]
  76. McGuire, B.A. bmcguir2/astromol: Added n-methyl formamide detection. 2021. [Google Scholar] [CrossRef]
  77. Roucou, A.; Kleiner, I.; Goubet, M.; Bteich, S.; Mouret, G.; Bocquet, R.; Hindle, F.; Meerts, W.L.; Cuisset, A. Towards the Detection of Explosive Taggants: Microwave and Millimetre-Wave Gas-Phase Spectroscopies of 3-Nitrotoluene. ChemPhysChem 2018, 19, 1056–1067. [Google Scholar]
  78. Venables, D. Chapter 12 - Spectroscopic Measurement of Pollutant Gases. In The Quality of Air;Comprehensive Analytical Chemistry; de la Guardia, M., Armenta, S., Eds.; Elsevier, 2016; Vol. 73, pp. 295–319. [Google Scholar] [CrossRef]
  79. Chen, W.; Venables, D.S.; Sigrist, M.W. (Eds.) Advances in Spectroscopic Monitoring of the Atmosphere, 1 ed.; Elsevier: Amsterdam, 2021. [Google Scholar]
  80. Kistenev, Y.V.; Teteneva, A.V.; Sorokina, T.V.; Knyazkova, A.I.; Zakharova, O.A.; Cuisset, A.; Vaks, V.L.; Domracheva, E.G.; Chernyaeva, M.B.; Anfertev, V.A.; et al. Diagnosis of diabetes based on analysis of exhaled air by terahertz spectroscopy and machine learning. Opt. Spectrosc. 2020, 128, 805–810. [Google Scholar] [CrossRef]
  81. Makarov, G.N. Low energy methods of molecular laser isotope separation. Phys. Usp. 2015, 58, 670–700. [Google Scholar] [CrossRef]
  82. Dridi, N.; Maaroufi, N.; Manceron, L.; Rotger, M.; Aroui, H. Measurement and modeling of self-broadening coefficients of the ν3 and 2ν3-ν3 bands of methyl chloride. J. Quant. Spectrosc. Radiat. Transf. 2019, 235, 108–119. [Google Scholar] [CrossRef]
  83. Dral, P.O. (Ed.) Quantum Chemistry in the Age of Machine Learning; Elsevier: Amsterdam, 2022. [Google Scholar]
  84. Zwölf, C.M.; Moreau, N.; Dubernet, M.L. New model for datasets citation and extraction reproducibility in VAMDC. J. Mol. Spectrosc. 2016, 327, 122–137. [Google Scholar] [CrossRef]
  85. Zwölf, C.M.; Moreau, N.; Ba, Y.A.; Dubernet, M.L. Implementing in the VAMDC the new paradigms for data citation from the research data alliance. Data Sci. J. 2019, 18, 4–4. [Google Scholar] [CrossRef]
  86. Hill, C.; Gordon, I.E.; Kochanov, R.V.; Barrett, L.; Wilzewski, J.S.; Rothman, L.S. HITRANonline: An online interface and the flexible representation of spectroscopic data in the HITRAN database. J. Quant. Spectrosc. Radiat. Transf. 2016, 177, 4–14. [Google Scholar] [CrossRef]
  87. Skinner, F.M.; Gordon, I.E.; Hill, C.; Hargreaves, R.J.; Lockhart, K.E.; Rothman, L.S. Referencing sources of molecular spectroscopic data in the era of data science: application to the HITRAN and AMBDAS databases. Atoms 2020, 8, 16. [Google Scholar] [CrossRef]
  88. Wilkinson, M.D.; Dumontier, M.; Aalbersberg, I.J.; Appleton, G.; Axton, M.; Baak, A.; Blomberg, N.; Boiten, J.W.; da Silva Santos, L.B.; Bourne, P.E.; et al. The FAIR Guiding Principles for scientific data management and stewardship. Sci. Data 2016, 3, 160018. [Google Scholar] [CrossRef] [PubMed]
  89. Moreau, N.; Zwolf, C.M.; Ba, Y.A.; Richard, C.; Boudon, V.; Dubernet, M.L. The VAMDC Portal as a Major Enabler of Atomic and Molecular Data Citation. Galaxies 2018, 6. [Google Scholar] [CrossRef]
Figure 1. Illustration of the portion of calculated CH4 energy levels (as a function of the rotational quantum number J) that can be corrected (“marvelized”) through the MARVEL procedure. Of course this portion may increase in the future, as more spectroscopic lines are assigned.
Figure 1. Illustration of the portion of calculated CH4 energy levels (as a function of the rotational quantum number J) that can be corrected (“marvelized”) through the MARVEL procedure. Of course this portion may increase in the future, as more spectroscopic lines are assigned.
Preprints 242810 g001
Figure 2. Assignment status of the 12CH4 line list in HITRAN2024. Top: line intensities at 296 K of all transitions, on a logarithmic scale (intensities scaled by natural isotopic abundance, as in HITRAN). Each transition is colored according to its quantum-number assignment: fully assigned (blue; upper and lower global and local quanta all given), partially assigned (orange; at least one of these four fields missing, e.g. only the lower-state vibrational label), or unassigned (red; no quantum numbers given). Unassigned transitions are drawn on top for visibility. Bottom: line intensities summed per Δ ν ≃ 46 cm − 1 bin for each category (the 0 − 14 , 000 cm − 1 range being divided in 300 bins), on a logarithmic scale.
Figure 2. Assignment status of the 12CH4 line list in HITRAN2024. Top: line intensities at 296 K of all transitions, on a logarithmic scale (intensities scaled by natural isotopic abundance, as in HITRAN). Each transition is colored according to its quantum-number assignment: fully assigned (blue; upper and lower global and local quanta all given), partially assigned (orange; at least one of these four fields missing, e.g. only the lower-state vibrational label), or unassigned (red; no quantum numbers given). Unassigned transitions are drawn on top for visibility. Bottom: line intensities summed per Δ ν ≃ 46 cm − 1 bin for each category (the 0 − 14 , 000 cm − 1 range being divided in 300 bins), on a logarithmic scale.
Preprints 242810 g002
Figure 3. Comparison of (accurate) experimental data from the HITRAN database [2] and (complete) calculated data from the ExoMol database [10] for the acetylene (C2H2) molecule. For ExoMol data, we used the so-called super-lines (see subSection 2.3), since the number of individual lines is extremely huge. We can see that theoretical data are much more complete than the experimental ones. The insert shows that, however, theoretical lines may differ from experimental ones in some spectral regions.
Figure 3. Comparison of (accurate) experimental data from the HITRAN database [2] and (complete) calculated data from the ExoMol database [10] for the acetylene (C2H2) molecule. For ExoMol data, we used the so-called super-lines (see subSection 2.3), since the number of individual lines is extremely huge. We can see that theoretical data are much more complete than the experimental ones. The insert shows that, however, theoretical lines may differ from experimental ones in some spectral regions.
Preprints 242810 g003
Figure 4. Effective Hamiltonian model extrapolation illustrated with the case of the ν 3 band of SiF4 at 296 K. Green plots correspond to an effective Hamiltonian fitted using full assignments up to J = 80 as in Ref. [68]. Blue plots correspond to a fit restricted to J ≤ 20 . (a) Comparison of both cases with the experiment (in red) for a small portion of the P branch around J = 52 : extrapolation from the low-J fit is bad. (b) Same comparison for the overview of the whole band: the inaccuracy of the blue plot is less visible at this scale; but we can see that hot bands are missing in the simulation. (c) Rovibrational energy levels: extrapolation well above the maximum assigned J value are unreliable, with an erratic polynomial behavior.
Figure 4. Effective Hamiltonian model extrapolation illustrated with the case of the ν 3 band of SiF4 at 296 K. Green plots correspond to an effective Hamiltonian fitted using full assignments up to J = 80 as in Ref. [68]. Blue plots correspond to a fit restricted to J ≤ 20 . (a) Comparison of both cases with the experiment (in red) for a small portion of the P branch around J = 52 : extrapolation from the low-J fit is bad. (b) Same comparison for the overview of the whole band: the inaccuracy of the blue plot is less visible at this scale; but we can see that hot bands are missing in the simulation. (c) Rovibrational energy levels: extrapolation well above the maximum assigned J value are unreliable, with an erratic polynomial behavior.
Preprints 242810 g004
Figure 5. Plot of HITRAN2024 [2] data for 12CH4. Uncertainty boxes are plotted in blue. The wavenumber uncertainty has been multiplied by 1000 for visibility. For each line, the HITRAN uncertainty code was converted to the lower bound value of the corresponding range (see Table 5 of Ref. [69] for uncertainty code definition).
Figure 5. Plot of HITRAN2024 [2] data for 12CH4. Uncertainty boxes are plotted in blue. The wavenumber uncertainty has been multiplied by 1000 for visibility. For each line, the HITRAN uncertainty code was converted to the lower bound value of the corresponding range (see Table 5 of Ref. [69] for uncertainty code definition).
Preprints 242810 g005
Figure 6. An example of custom line list output format building using HITRANonline.
Figure 6. An example of custom line list output format building using HITRANonline.
Preprints 242810 g006
Figure 7. Cumulative number of interstellar molecules, as a function of year. This plot was generated using the astromol tool [76].
Figure 7. Cumulative number of interstellar molecules, as a function of year. This plot was generated using the astromol tool [76].
Preprints 242810 g007
Figure 8. Air-broadening ( γ air ) coefficient for 12CH4 in the HITRAN database.
Figure 8. Air-broadening ( γ air ) coefficient for 12CH4 in the HITRAN database.
Preprints 242810 g008
Table 1. The different databases for molecular spectroscopy and their main characteristics (as of November 2026). Only databases providing spectroscopic parameters of gas-phase molecules are listed; atomic, collisional, kinetic and solid-phase databases are not included. The # molecules column counts the number of distinct molecular species, regardless of the number of isotopologues included; ions and structural isomers are counted separately. Atomic data are present in some databases (HITRAN, JPL, for instance), but are not counted here.
Table 1. The different databases for molecular spectroscopy and their main characteristics (as of November 2026). Only databases providing spectroscopic parameters of gas-phase molecules are listed; atomic, collisional, kinetic and solid-phase databases are not included. The # molecules column counts the number of distinct molecular species, regardless of the number of isotopologues included; ions and structural isomers are counted separately. Atomic data are present in some databases (HITRAN, JPL, for instance), but are not counted here.
Name Type Datab # molecules Range Accessc Main applications Comments
HITRAN [2] Hybrid L, X 60 MW–IR Q, A Earth, planets
HITEMP [26] Hybrid L 8 MW–IR F Combustion, exoplanets Dedicated to high temperatures
PNNLa [6] Experimental X 625 IR Q Low-resolution analysis Fixed temperatures and pressures
MPI-Mainz [58] Experimental X 1326 Vis–UV F Earth Also includes photolysis rates
GEISA [24] Hybrid L, X 58 MW–UV Q, F Earth, planets Development stopped in Dec. 2024
MoLLIST [59] Hybrid L, X 38 IR–Vis–UV F Astrophysics Many diatomics; partly in ExoMol
SESAM [60] Calculated L 2 VUV Q, F Interstellar medium Electronic spectra of diatomic molecules
Kurucz [61] Hybrid L 47 IR–UV F Astrophysics Mostly diatomics
VALD3 [62] Hybrid L 8 IR–UV Q Astrophysics Mainly atomic; molecular data from Kurucz, except TiO
JPL [49] Hybrid L 180 MW–THz Q, F, Ad Earth, interstellar medium
CDMS [52] Hybrid L 572 MW–THz Q, F, Ad Earth, interstellar medium
LSD [41] Calculated L 21 MW–THz Q Interstellar medium
CaSDa [20] Calculated L, X 10 MW–IR Q Earth, planets, industry Full eigenvector description provided
CDSD [53] Calculated L 1 IR F Earth, planets Dedicated to carbon dioxide
S&MPO [54] Calculated L 1 MW–IR Q Earth Dedicated to ozone
TheoReTS [8] Calculated L, SL 9 MW–IR Q Earth, planets
ExoMol [10] Calculated L, SL, X 101 MW–IR–Vis F, A Exoplanets
NASA-Ames [63] Calculated L 6 IR F Earth, astrophysics Spectroscopic constants to come
Spectra [64] Hybrid L 65 MW–UV Q Earth, planets Union of HITRAN & GEISA, plus original IAO data
W@DIS [56] Hybrid L, X 28 MW–UV Q Earth, astrophysics Compilation & quality assessment of published data
PAHdb [55] Hybrid I ∼10,000e IR Q Interstellar medium Separate theoretical and experimental libraries
PAH (Cagliari) [65] Calculated I, X 160 IR–UV F Interstellar medium 40 molecules in four charge states
a Included in the cross-section part of HITRAN. b L = individual spectral lines, SL = super-lines (see text), X = cross-sections, I = integrated band intensities. c Q = online query (on-demand extraction by species, spectral range, intensity threshold, etc.), F = static file download, A = programmatic API. d Third-party Python client, developed by the Astropy community. e Approximate count: PAHdb lists 10 749 species, each charge state being counted separately; some entries correspond to the same molecule in different spin multiplicities.
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.
Copyright: This open access article is published under a Creative Commons CC BY 4.0 license, which permit the free download, distribution, and reuse, provided that the author and preprint are cited in any reuse.