Magnetic Field–Driven Carrier Transport in a Stenosed Bifurcating Artery

Submitted:

02 November 2026

Posted:

04 November 2026

You are already at the latest version

Abstract
Magnetic drug targeting in stenosed arteries is affected by the local magnetic field distribution and the unsteady nature of blood flow. In this work, a two-dimensional finite element model was developed for a bifurcating artery with a 40% stenosis to examine the transport of 100 nm paramagnetic Fe2O3 carriers under pulsatile flow. The model couples the blood flow field, an externally applied magnetic field, and convection-diffusion transport with magnetophoretic migration. Pulsation frequencies of 1 and 2 Hz and magnetic fields of 0-0.50 T were considered. At 0.50 T, the maximum value of (B·∇)B in the target region was approximately 0.62×103T2/m. The carrier concentration at the stenosis increased from 0.63 to approximately 0.89 mol/m3 after 10 s at 1 Hz, whereas a final concentration of only about 0.65 mol/m3 was obtained at 2 Hz. The corresponding concentration enhancements were approximately 41% and 3%, respectively. Increasing the magnetic field also increased carrier accumulation: the concentration remained close to 0.63 mol/m3 at 0 T and reached approximately 0.695 and 0.89 mol/m3 at 0.25 and 0.50 T, respectively. The results indicate that magnetic carrier localization in a stenosed bifurcation is controlled by the competition between flow-induced convection and magnetophoretic migration, with stronger accumulation obtained at lower pulsation frequency and higher magnetic field strength.
Keywords: 
;  ;  ;  
Subject: 
Physical Sciences  -   Biophysics
Targeted drug delivery is intended to increase the concentration of a therapeutic agent at a diseased site while reducing unnecessary exposure of healthy tissues. The development of nano and microscale carriers has considerably expanded this approach because carrier size, composition, surface properties, and functionalization can be tailored for different therapeutic applications [1,2]. However, intravascular delivery remains challenging. Once introduced into the bloodstream, carriers must remain stable in circulation, avoid rapid clearance, reach the intended vascular region, migrate toward the vessel wall, and remain there sufficiently long for deposition, adhesion, or drug release [3,4]. Consequently, the success of vascular drug delivery is determined not only by carrier properties but also by the local hemodynamic environment.
Blood velocity, wall shear rate, arterial curvature, stenosis, and bifurcation can strongly alter carrier transport. These geometric features modify the local velocity field and may generate flow separation, recirculation, and regions of increased residence time, thereby influencing particle margination and deposition. Decuzzi et al. demonstrated the importance of particle geometry for vascular delivery [5], while Korin et al. showed that the elevated shear associated with obstructed vessels can itself be exploited for site selective drug delivery [6]. Computational studies of stenosed carotid bifurcations have further demonstrated that carrier size, release position, and vascular geometry strongly influence particle trajectories and residence time [7]. Patient specific modeling has similarly shown that nanoparticle deposition can be highly nonuniform because of the complex interaction between arterial geometry and local hemodynamics [8,9].
Because carriers transported by the bloodstream tend to follow convective flow, passive transport alone may provide insufficient accumulation at a selected vascular location. Magnetic drug targeting (MDT) provides an additional mechanism by attaching therapeutic agents into magnetically responsive carriers and applying an external magnetic field to redirect them toward the target. Experimental studies have demonstrated magnetic capture in relatively large arteries [10], magnetically assisted thrombolytic delivery [11], and delivery of superparamagnetic iron oxide nanoparticles to atherosclerotic plaques [12]. These studies support the feasibility of magnetic targeting for vascular applications, but they also show that successful localization depends on the ability of magnetic forces to compete with blood flow driven transport.
The underlying physics of MDT is therefore governed by the balance between magnetic migration and hydrodynamic forces. The magnetic response depends on both the magnetic field strength and its spatial gradient, whereas the opposing hydrodynamic transport depends on blood velocity, viscosity, carrier size, and local vessel geometry. Haverkort et al. showed computationally that magnetic particle capture in coronary and carotid arteries is closely related to the ratio between magnetic and drag forces and that curvature and branching cause substantial departures from predictions based on a straight vessel [13]. Gitter and Odenbach subsequently considered magnetic targeting in a branched artery with non-Newtonian blood behavior [14], while Larimi et al. investigated magnetic nanoparticle targeting directly in a bifurcated vessel [15].
Carrier size introduces an additional constraint because particles suitable for biomedical circulation are not necessarily the easiest to manipulate magnetically. Lunnoo and Puangmali reported a strong reduction in capture efficiency as magnetic particles became smaller and showed that particles in the superparamagnetic size range can be particularly difficult to retain under arterial flow conditions [16]. They further noted that targeting becomes more favorable when the magnet is closer to the vessel and the blood velocity is lower because the magnetic field gradient decreases rapidly with distance. Mahmoodpour et al. investigated the trajectory and capture of magnetic drug carriers following injection into a vessel [17], and Lee et al. showed that magnetic moment, magnet to vessel distance, release position, and blood rheology jointly influence superparamagnetic nanoparticle motion [18].
More recent studies have moved toward physiologically realistic and patient specific arterial geometries. Shamloo et al. investigated magnetic targeting of an atherosclerotic plaque in a patient specific coronary artery [19], while Hewlin et al. developed a two way coupled Eulerian–Lagrangian model for magnetic nanoparticle targeting under pulsatile flow in a diseased carotid bifurcation [20]. Lindemann et al. examined magnetic targeting in a three-dimensional multibranched vessel network and showed that magnetic configuration, carrier diameter, magnetic moment, and magnet distance all affect targeting efficiency [21]. Manshadi et al. likewise demonstrated the coupled influence of particle size, blood flow, and magnetic forcing on arterial delivery [22]. In studies of magnetic microbubbles, Shamloo et al. showed that magnetic enhancement of wall adhesion is closely connected to local flow reversal and carrier residence time, indicating that a stronger magnetic action does not necessarily lead to improved deposition if the carrier is rapidly convected away from the target [23].
Most arterial MDT studies describe the carrier phase using a Lagrangian formulation, in which individual particle trajectories are calculated from force balances involving magnetic, drag, Brownian, lift, gravitational, or other relevant forces [13–23]. Such an approach is particularly useful for determining individual trajectories and capture efficiency. A different description is obtained using an Eulerian based approach, in which the transported therapeutic phase is represented as a continuous concentration field. Buchete et al. clearly distinguish these approaches: Lagrangian methods follow individual particles, whereas Eulerian methods describe the dispersed material as a concentration distributed throughout the computational domain.
Concentration based models have already been used successfully for vascular drug transport. Calo et al. coupled blood flow with an advection–diffusion description of therapeutic transport in patient specific coronary arteries [24]. Hossain et al. subsequently developed a coupled model for free drug and drug encapsulated nanoparticle transport in coronary artery walls, accounting for convection, diffusion, and drug release [25]. Xu and Kleinstreuer included both Brownian diffusion and red blood cell-induced shear diffusion in their concentration based nanoparticle transport model and showed that shear enhanced dispersion can influence delivery even in relatively large arteries [26]. More recently, Eulerian modeling has also been applied to Fe3O4-containing blood flow in diseased arteries, although such studies have generally employed simplified arterial geometries and idealized magnetic field descriptions [27].
Despite these developments, a gap remains between the large body of MDT studies based on individual particle trajectories and continuum approaches describing the spatial concentration of the transported therapeutic phase. This distinction is particularly important in a bifurcated artery, where the incoming magnetic carrier concentration is redistributed between outlet branches by convection, while diffusion and magnetically induced transport can modify that natural distribution. A concentration-based formulation can therefore provide information complementary to discrete particle tracking by directly resolving local enrichment, depletion, concentration gradients, and downstream redistribution.
In the present study, a coupled multiphysics model is developed in COMSOL Multiphysics using the Laminar Flow, Magnetic Fields, and Transport of Diluted Species interfaces to investigate magnetically guided carrier transport in a bifurcated arterial geometry. The blood flow field, externally imposed magnetic field, and magnetic carrier concentration are resolved within the same computational framework. Particular attention is given to the competition among flow-driven convection, diffusion, vascular geometry, and magnetophoretic migration, with the objective of determining whether an applied magnetic field can modify the natural carrier distribution and enhance localization of the magnetic carriers within the intended vascular region.

1. Problem Description

The computational domain consists of a two-dimensional bifurcating arterial segment containing a localized stenosis in one of the outlet branches, as shown in Figure 1. The geometry was designed to examine the redistribution of blood and a magnetically responsive carrier as the flow passes through a vascular bifurcation and a locally narrowed region. The parent vessel has a width of 7 mm and extends 70 mm upstream of the bifurcation. The vessel divides into two outlet branches separated by an angle of 56 ∘ , with each branch having a nominal width of 6.3 mm. The upper branch extends approximately 55 mm downstream. A smooth enlargement with a characteristic junction radius of 5.6 mm is incorporated near the bifurcation to provide a gradual geometric transition. A localized 40% stenosis is introduced in the upper outlet branch, reducing the vessel width from 6.3 mm to a minimum of 3.78 mm over a stenotic length of approximately 18 mm.
Two permanent magnets are positioned externally around the bifurcation and stenosed region to generate a spatially nonuniform magnetic field. The resulting field gradient produces magnetophoretic migration of the magnetic carriers in addition to their transport by the underlying blood flow. The model therefore resolves the combined effects of vascular geometry, convection, diffusion, and magnetic migration on the spatial distribution of the carrier concentration.
A mesh independence study was performed to ensure that the numerical solution was not sensitive to further mesh refinement, Figure 1 (b). Based on this analysis, the final computational mesh consisted of 181 , 136 elements, including 164 , 222 triangular elements and 16 , 914 quadrilateral elements. The minimum and average element qualities were 0.1843 and 0.7706 , respectively. This mesh was therefore selected for all subsequent simulations as a suitable compromise between numerical accuracy and computational cost.

2. Governing Equations

2.1. Magnetic Field

The magnetic field used for particle targeting is produced by a permanent magnet and is evaluated assuming magnetostatic conditions. Since no free electric current is present within the computational domain, the magnetic field is governed by
∇ · B = 0 , ∇ × H = 0 ,
together with the constitutive relation
B = μ 0 ( H + M ) ,
where B and H denote the magnetic flux density and magnetic field intensity, respectively, μ 0 is the permeability of free space, and M represents the magnetization of the permanent magnet. Because the magnetic field varies spatially within the vascular domain, a non-zero magnetic field gradient term, ( B · ∇ ) B , is generated. This term provides the driving force responsible for the magnetophoretic migration of the magnetic particles.

2.2. Mass and Momentum Balance

Blood is treated as an incompressible Newtonian fluid with constant density and dynamic viscosity. Blood is inherently non-Newtonian because of the presence of red blood cells; however, for vessels with characteristic dimensions on the millimeter scale and Reynolds numbers of Re = O ( 10 2 ) , the associated shear rates are sufficiently high for the Newtonian approximation to provide a reasonable representation of the flow.
The conservation equations for mass and momentum are written as[28,29]
∇ · u f = 0 ,
ρ ∂ u f ∂ t + u f · ∇ u f = − ∇ p + μ ∇ 2 u f + F mag ,
where u f denotes the fluid velocity, ρ is the effective density of the particle containing suspension, μ is the dynamic viscosity, and p represents the pressure. The contribution of the magnetic field to the momentum equation is described using the Kelvin magnetic body force,
F mag = χ f μ 0 ( B · ∇ ) B ,
where χ f is the effective volumetric magnetic susceptibility of the particle laden fluid. This force represents the bulk response of the suspension to the imposed non-uniform magnetic field.

2.3. Particle Transport

The spatial and temporal evolution of the magnetic particle concentration is described using a convection-diffusion formulation [30],
∂ c ∂ t + ∇ · N = 0 ,
where c is the magnetic carrier and N represents the total particle flux. The flux contains contributions from Brownian diffusion, fluid convection, and magnetically induced particle migration,
N = − D ∇ c + c u f + v mig ,
where D is the diffusion coefficient and v mig is the particle migration velocity relative to the carrier fluid.
For a spherical magnetic particle, the magnetophoretic force generated by the non-uniform magnetic field is expressed as
F mag , p = 4 3 π R p 3 Δ χ v μ 0 ( B · ∇ ) B ,
where R p is the particle radius and Δ χ represents the magnetic susceptibility difference between the particle and the surrounding fluid,
Δ χ v = χ p − χ f .
For sufficiently small particles moving at a low particle Reynolds number, the hydrodynamic resistance can be described using Stokes drag,
F drag = − 6 π μ R p ( v p − u f ) ,
where v p is the particle velocity.
Because the particle relaxation time is small, particle inertia is neglected and the magnetic force is assumed to be balanced by viscous drag,
F mag , p + F drag = 0 .
The resulting particle velocity relative to the surrounding fluid gives the magnetophoretic migration velocity,
v mig = 2 R p 2 Δ χ v 9 μ 0 μ ( B · ∇ ) B .
Accordingly, the imposed magnetic field affects the transport process in two distinct ways. First, it contributes a magnetic body force to the momentum balance of the particle laden suspension. Second, the magnetic field gradient produces a relative migration of the magnetic particles with respect to the underlying blood flow.

2.4. Boundary Conditions

A time-dependent normal inflow velocity was prescribed at the inlet to represent pulsatile blood flow. The imposed waveform was defined as [31]
u in ( t ) = 0.7 τ 2 exp ( − τ 2 ) sin π τ 2 + 0.05 sin ( π τ ) + 0.06 ,
where u in is expressed in m / s and τ = s f t is a dimensionless time variable. The scaling parameter s f was set to 2 s − 1 and 4 s − 1 to obtain pulsation frequencies of 1 and 2 Hz, respectively. The first term introduces the initial transient response, whereas the remaining sinusoidal term represents the sustained periodic component of the inlet flow.
A no-slip condition was imposed along all arterial walls,
u f = 0 .
For the magnetic carrier transport, a no flux boundary condition was applied at the arterial walls,
n · N = 0 ,
where n denotes the outward unit normal vector and N is the total carrier flux. This condition prevents transport of the magnetic carriers across the vessel wall, while allowing their concentration to redistribute within the fluid domain through convection, diffusion, and magnetophoretic migration.

3. Material Properties and Model Parameters

The magnetic carriers were represented as paramagnetic Fe2O3 nanoparticles with a characteristic diameter of 100 nm. The volumetric magnetic susceptibility contrast between the particles and the surrounding fluid was taken as
Δ χ v = χ v , p − χ v , f = 5.05 × 10 − 3 .
Blood was modeled as an incompressible Newtonian fluid with a density of ρ = 1060 kg / m 3 and a dynamic viscosity of μ = 3.5 × 10 − 3 Pa s . The initial concentration of the magnetic carrier was set to 100 mg / L . Using the molar mass of Fe2O3 ( 159.69 g / mol ), this corresponds to c = 0.626 mol / m 3 , which was approximated as 0.63 mol / m 3 in the simulations. Here, c represents the molar concentration of Fe2O3 contained in the dispersed nanoparticle phase rather than the molar concentration of individual nanoparticles.

4. Magnetic Field Distribution

Figure 2 shows the magnetic field generated by the two permanent magnets positioned around the stenosed bifurcation. The magnetic flux density is concentrated near the magnet pole faces and decreases with increasing distance from the magnets, reaching a maximum value of approximately 0.5 T in the stenosis region, while the field lines indicate that the selected magnet arrangement directs the magnetic flux through the bifurcation toward the stenosed branch. The corresponding magnetic field gradient term, ( B · ∇ ) B , is strongly localized near the magnet edges and pole tips and reaches a maximum of approximately 2.99 × 10 3 T 2 / m and 0.62 × 10 3 T 2 / m in the stenosis region. Since the magnetophoretic force acting on the paramagnetic carriers is proportional to this field gradient term, these high gradient regions are primarily responsible for driving particle migration rather than the magnetic flux density alone. Consequently, the localized magnetic field gradient near the stenosis is expected to promote transverse migration of the carriers toward the target region, where the magnetic transport competes with convection imposed by the blood flow.

5. Results and Discussion

5.1. Effect of Pulsation Frequency on the Hemodynamic Response

Figure 3 shows the temporal evolution of the velocity field for the two pulsatile inlet conditions corresponding to frequencies of 1 and 2 Hz. In both cases, the flow remains predominantly aligned with the parent vessel before undergoing substantial redistribution at the bifurcation. Pronounced spatial variations develop near the junction and within the stenosed branch, where the combined effects of flow division, change in flow direction, and local reduction in vessel width generate strong velocity gradients. Local acceleration is clearly observed near the stenosis throat, whereas lower velocity regions develop close to the arterial walls and around the enlarged bifurcation region. These features are consistent with the momentum balance described earlier, where spatial acceleration becomes increasingly important in regions of rapid geometric variation [32–36].
The influence of pulsation frequency is also evident from the instantaneous velocity contours. For the 1 Hz condition, corresponding to a cycle period of 1 s, the velocity field evolves comparatively gradually. Increasing the pulsation frequency to 2 Hz decreases the cycle period to 0.5 s and therefore doubles the rate at which the imposed inlet velocity varies. Consequently, the velocity field shown in Figure 3(b) undergoes more rapid temporal changes than that in Figure 3(a), particularly near the bifurcation and stenosed region. This behavior reflects the increased influence of unsteady inertia at the higher pulsation frequency.
The temporal velocity profiles in Figure 4 provide a quantitative comparison between the velocity measured at the inlet and within the stenosed branch. For the 1 Hz condition [Figure 4(a)], the initial transient produces a maximum inlet velocity of approximately 0.40 m / s at t ≈ 1.8 s , whereas the corresponding velocity within the stenosed region is approximately 0.36 m / s , representing a difference of about 10 % . Following this initial peak, the velocity decreases significantly before another maximum develops near t ≈ 5.2 s . At this stage, the inlet and stenosis velocities are approximately 0.145 and 0.115 m / s , respectively, corresponding to a difference of approximately 21 % . A further oscillation produces an inlet velocity of approximately 0.15 m / s near t ≈ 9 s , while the corresponding velocity within the stenosed region remains approximately 0.12 - 0.13 m / s .
In comparison, the 2 Hz condition [Figure 4(b)] exhibits a considerably more rapid oscillatory response. Following the initial transient, approximately two complete velocity oscillations occur every second, which agrees with the prescribed 2 Hz inlet condition. The successive velocity maxima are approximately 0.13 – 0.14 m / s , while the minimum values approach 0.01 – 0.02 m / s . The inlet and stenosis velocity profiles remain nearly synchronized throughout the established periodic regime, indicating only a small phase difference between the two monitoring locations. However, the velocity magnitude within the stenosed branch generally remains slightly below the inlet value because the incoming flow has already been redistributed between the two outlet branches.
The flow characteristics can be further interpreted in terms of the Reynolds number. Using the parent vessel width of 7 mm , blood density of 1060 kg / m 3 , dynamic viscosity of 3.5 × 10 − 3 Pa s , and a long time mean inlet velocity of approximately 0.06 m / s , the characteristic Reynolds number is approximately Re = 127 . During the established periodic portion of the waveform, the inlet velocity varies approximately between 0.01 and 0.11 m / s , corresponding to instantaneous Reynolds numbers ranging from approximately 21 to 233. During the initial transient, when the velocity reaches approximately 0.40 m / s , the instantaneous Reynolds number increases temporarily to approximately 848. These values remain consistent with the laminar flow formulation adopted in the present simulations, while also indicating that inertial effects are appreciable during the initial transient and in regions of strong geometric variation.
The two pulsation frequency cases have essentially the same characteristic Reynolds number range because the amplitude and mean value of the prescribed inlet waveform are unchanged. The main difference between the two conditions is therefore the rate of acceleration and deceleration rather than the characteristic ratio of inertial to viscous forces. The effect of pulsation frequency can be further characterized using the Womersley number, defined as
α = L c ω ρ μ ,
where L c is the characteristic length scale, ω = 2 π f is the angular frequency, ρ is the fluid density, and μ is the dynamic viscosity. The Womersley number represents the relative importance of unsteady inertial effects to viscous effects in pulsatile flow. Using the parent characteristic length of R = 3.5 mm , ρ = 1060 kg / m 3 , and μ = 3.5 × 10 − 3 Pa s , the Womersley number is approximately 4.83 at 1 Hz and 6.83 at 2 Hz. The larger value at 2 Hz indicates a stronger influence of unsteady inertia relative to viscous momentum diffusion, consistent with the more rapid temporal variations observed in Figure 3(b) and Figure 4(b).
It should also be noted that the lower velocity measured within the stenosed branch in Figure 4 does not imply that the constriction itself produces a local deceleration. The velocity contours in Figure 3 clearly indicate local acceleration near the stenosis throat as the available flow area decreases. However, the monitoring location used for Figure 4 is positioned downstream of the bifurcation, where only a fraction of the total inlet flow enters the stenosed branch. The difference between the inlet and stenosis velocities therefore results from the combined effects of flow division, local vessel geometry, and pulsatile forcing.
These hemodynamic characteristics are directly relevant to the subsequent magnetic carrier transport behavior. As established in the particle transport formulation, magnetic carriers are simultaneously subjected to convection by the blood flow, diffusion, and magnetophoretic migration. During the high velocity portion of each pulsation cycle, convective transport becomes stronger and the carriers pass more rapidly through the bifurcation, thereby reducing the time available for magnetic deflection. In contrast, during the low velocity portion of the cycle, the residence time of the carriers within the high gradient magnetic region increases, allowing magnetophoretic migration to compete more effectively with convection. The 2 Hz condition therefore provides more frequent but shorter low velocity intervals, whereas the 1 Hz condition provides comparatively longer intervals for magnetically driven migration. These differences are expected to influence the subsequent temporal evolution and accumulation of the magnetic carriers near the stenosed target region.

5.2. Magnetic Carrier Transport and Accumulation

Figure 5 shows the temporal evolution of the magnetic-carrier concentration for pulsatile inlet frequencies of 1 and 2 Hz. At the initial stage ( t = 0.01 s ), the concentration distribution remains nearly uniform throughout the vascular domain, with only a small variation near the bifurcation. As time progresses, the carriers are transported downstream by the blood flow while simultaneously undergoing diffusion and magnetophoretic migration. A localized region of increased concentration gradually develops along the stenosed branch, where the magnetic field gradient is strongest. This enrichment becomes clearly visible at t = 0.1 s and is substantially intensified at t = 1 and 10 s for the 1 Hz condition. In contrast, the 2 Hz case exhibits a weaker and more spatially distributed concentration enhancement, indicating that increasing the pulsation frequency reduces the extent of carrier localization within the magnetically targeted region.
The difference between the two cases can be understood from the competition between convective and magnetophoretic transport. The magnetic properties of the particles and the applied magnetic field distribution remain unchanged; therefore, the difference in carrier accumulation originates primarily from the change in the temporal characteristics of the flow. At 1 Hz, each pulsation cycle lasts approximately 1 s , whereas the cycle duration decreases to approximately 0.5 s at 2 Hz. The lower frequency condition consequently provides longer time intervals during which the local fluid velocity remains relatively low, increasing the residence time of the carriers in the high gradient magnetic region. This allows magnetophoretic migration to compete more effectively with downstream convection. At 2 Hz, the flow accelerates and decelerates more rapidly, shortening the available migration time during each cycle and promoting more frequent convective redistribution of the carriers through the bifurcation.
Figure 6 provides a quantitative comparison of this behavior. The monitored concentration initially remains close to 0.63 mol / m 3 for both pulsation frequencies. For the 1 Hz condition, the concentration increases rapidly during the early stages of transport, reaching approximately 0.74 mol / m 3 at t ≈ 1 s and about 0.78 mol / m 3 at t ≈ 2 s . The rate of accumulation subsequently decreases, although the concentration continues to rise throughout the simulation, reaching approximately 0.89 mol / m 3 at t = 10 s . Relative to the initial concentration, this corresponds to an enrichment of approximately 41 % .
In comparison, the 2 Hz condition produces only a small increase in concentration over the same time interval. The concentration rises from approximately 0.63 mol / m 3 initially to only about 0.65 mol / m 3 at t = 10 s , corresponding to an increase of approximately 3 % . At the end of the simulation, the concentration obtained at 1 Hz is therefore approximately 0.24 mol / m 3 higher than that obtained at 2 Hz and is about 37 % greater relative to the 2 Hz value. This marked difference demonstrates that carrier accumulation is highly sensitive to the time scale of the pulsatile flow even when the mean inlet velocity, magnetic field strength, particle properties, and vascular geometry are unchanged.
This behavior is also consistent with the hemodynamic characteristics discussed earlier. The two flow conditions have approximately the same characteristic Reynolds number range because the amplitude and mean value of the inlet waveform are unchanged. The major difference instead arises from the increased unsteady inertia at the higher pulsation frequency, as reflected by the increase in Womersley number from approximately 4.83 at 1 Hz to 6.83 at 2 Hz. The stronger unsteady response at 2 Hz increases the frequency of convective renewal near the stenosed region and reduces the duration over which the magnetic migration velocity can act effectively on the carriers. Conversely, the longer cycle at 1 Hz increases the residence time available for magnetic migration and leads to substantially greater concentration enhancement near the target region.
The observed frequency dependence is consistent with previous computational studies showing that magnetic targeting efficiency is governed by the competition between magnetic migration and hydrodynamic transport. Haverkort et al. [13] demonstrated that magnetic particle capture in arterial flow depends strongly on the relative magnitudes of magnetic and hydrodynamic forces, while Larimi et al. [15] showed that the bifurcation geometry and flow conditions significantly influence magnetic nanoparticle targeting. Similar observations were reported by Hewlin et al. [20], who found that increased convective transport can reduce the time available for magnetic particle capture under pulsatile arterial flow conditions. The present results extend this physical picture by showing that, even at comparable characteristic Reynolds numbers, changing the pulsation frequency alone can substantially alter the temporal accumulation of magnetic carriers within a stenosed bifurcating artery. It should be noted that different concentration ranges are used for the color scales in Figure 5(a) and Figure 5(b). Therefore, the contour colors should be interpreted primarily in terms of the spatial distribution within each case, whereas the direct quantitative comparison between the two pulsation frequencies is more appropriately obtained from Figure 6.

5.3. Effect of Magnetic Field

Figure 7 illustrates the effect of the applied magnetic field on both the velocity field and the spatial distribution of the magnetic carriers for B = 0 , 0.25 , and 0.50 T . In the absence of a magnetic field, the velocity field is governed by the imposed pulsatile inlet condition and the bifurcating arterial geometry. The incoming flow accelerates through the junction and is redistributed between the two outlet branches, with the highest velocities occurring along the central flow path and through the locally narrowed region. When the magnetic field is increased to 0.25 T , the overall velocity distribution remains largely comparable to the zero field condition, indicating that the magnetic contribution to the bulk momentum balance is still relatively weak compared with the dominant hydrodynamic effects. At 0.50 T , however, the velocity vectors show a more noticeable spatial irregularity in the vicinity of the bifurcation and stenosed branch. This disturbance remains localized and does not substantially alter the overall flow structure, suggesting that the magnetic field modifies the local momentum distribution without fundamentally changing the overall pulsatile flow pattern.
The stronger local disturbance observed at 0.50 T is consistent with the increase in the magnetic field-gradient term within the target region. The maximum value of ( B · ∇ ) B is zero at B = 0 , approximately 0.24 × 10 3 T 2 / m at 0.25 T , and 0.62 × 10 3 T 2 / m at 0.50 T in the stenosis region. Thus, increasing the applied field from 0.25 to 0.50 T increases the maximum magnetic field gradient term by approximately 33 % . Since the magnetic contribution to the momentum balance and the magnetophoretic migration of the carriers both depend on this field gradient term in the present formulation, the stronger and more spatially nonuniform forcing at 0.50 T can produce a localized perturbation of the velocity field near the bifurcation. This behavior is therefore described here as a magnetically induced flow disturbance rather than a formal hydrodynamic instability.
The influence of magnetic field strength is considerably more pronounced in the carrier concentration distributions shown in Figure 7(b). At B = 0 , the concentration remains at its initial value of approximately 0.63 mol / m 3 , and no distinct preferential accumulation is observed within the stenosed region. Introducing a magnetic field of 0.25 T produces a localized concentration enhancement near the stenosis, indicating that the magnetic carriers begin to deviate from purely flow following transport. A substantially stronger enrichment develops at 0.50 T , where the concentration approaches 0.90 mol / m 3 in the target region. The location of this enrichment coincides with the region of elevated magnetic field gradient identified previously, supporting the interpretation that the accumulation is driven primarily by magnetophoretic migration toward the high gradient region. The concentration field therefore responds much more strongly to increasing magnetic field strength than the bulk velocity field.
Figure 8 quantifies the temporal development of the carrier accumulation within the stenosed target region. In the absence of a magnetic field, the concentration remains essentially constant at approximately 0.63 mol / m 3 throughout the simulation, confirming that the hydrodynamic field alone does not generate sustained local enrichment. At 0.25 T , the concentration increases gradually and reaches approximately 0.695 mol / m 3 at t = 10 s , corresponding to an increase of approximately 10 % relative to the zero field concentration. The strongest response is obtained at 0.50 T , where the concentration increases rapidly during the early stage and continues to rise more gradually at later times, reaching approximately 0.89 mol / m 3 at t = 10 s . This corresponds to an enrichment of approximately 41 % relative to the zero field condition.
The temporal evolution at 0.50 T also indicates that the accumulation process is not uniform in time. The concentration initially rises rapidly, whereas the rate of increase progressively decreases as the simulation proceeds. This behavior suggests that the magnetic field initially drives a strong net carrier flux toward the target region, while the subsequent accumulation rate becomes increasingly moderated by the competing effects of downstream convection and diffusion away from the enriched region. At t = 10 s , the concentration at 0.50 T is approximately 0.194 mol / m 3 higher than that at 0.25 T . Taken together, Figure 7 and Figure 8 demonstrate that increasing the magnetic field strength substantially enhances magnetic carrier localization within the stenosed branch, while producing only a comparatively localized modification of the underlying hemodynamic field. At the highest field considered, the increased magnetic forcing is therefore sufficient to generate both a pronounced carrier enrichment zone and a measurable local disturbance of the flow near the bifurcation and stenosis.

6. Conclusions

The present study shows that the hemodynamic time scale plays a central role in determining whether magnetic carriers can accumulate within the stenosed region. The lower frequency condition provides longer low velocity intervals during each cycle, allowing the carriers to remain within the high gradient region for a longer period. Magnetophoretic migration can therefore compete more effectively with downstream convection at 1 Hz. At 2 Hz, the more rapid acceleration and deceleration of the flow shorten these intervals and promote repeated convective redistribution through the bifurcation. This explains the large difference in the final concentrations observed between the two frequencies. The corresponding increase in Womersley number from 4.83 to 6.83 further reflects the greater importance of unsteady inertia at the higher frequency.
In the absence of a magnetic field, the carriers remain predominantly governed by the underlying convective transport and no sustained enrichment develops at the stenosis region. As the magnetic field is increased, the concentration becomes progressively localized near the stenosis, where the field gradient term is largest. The increase in ( B · ∇ ) B from approximately 0.24 × 10 3 to 0.62 × 10 3 T 2 / m between 0.25 and 0.50 T, strengthens the magnetophoretic migration and produces a pronounced concentration zone within the stenosed branch. In contrast, the global velocity field is much less sensitive to magnetic field strength. Only at 0.50 T does a noticeable localized flow disturbance appear near the bifurcation, while the overall flow pattern remains largely preserved. These findings indicate that magnetic targeting is most effective when the magnetic field is sufficiently strong and the pulsatile flow provides adequate residence time for transverse carrier migration.

Author Contributions

Conceptualization, M.B.K. and M.M.; methodology, M.B.K. and M.M.; investigation, M.B.K. and M.M.; formal analysis, M.B.K. and M.M.; writing—original draft preparation, M.B.K.; writing—review and editing, M.B.K. All authors have read and agreed to the published version of the manuscript.

Data Availability Statement

All relevant data that support the findings of this study are provided within the article.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Mitchell, M.J.; Billingsley, M.M.; Haley, R.M.; Wechsler, M.E.; Peppas, N.A.; Langer, R. Engineering precision nanoparticles for drug delivery. Nat. Rev. Drug Discov. 2021, 20, 101–124. [Google Scholar] [CrossRef] [PubMed]
  2. Cheng, X.; Xie, Q.; Sun, Y. Advances in nanomaterial-based targeted drug delivery systems. Front. Bioeng. Biotechnol. 2023, 11, 1177151. [Google Scholar] [CrossRef] [PubMed]
  3. Haroon, H.; Hunter, A.; Farhangrazi, Z.; Moghimi, S. A brief history of long circulating nanoparticles. Adv. Drug Deliv. Rev. 2022, 188, 114396. [Google Scholar] [CrossRef] [PubMed]
  4. Buchete, N.-V.; Cicha, I.; Dutta, S.; Neofytou, P. Multiscale physics-based in silico modelling of nanocarrier-assisted intravascular drug delivery. Front. Drug Deliv. 2024, 4, 1362660. [Google Scholar] [CrossRef] [PubMed]
  5. Decuzzi, P.; Pasqualini, R.; Arap, W.; Ferrari, M. Intravascular delivery of particulate systems: does geometry really matter? Pharm. Res. 2009, 26, 235–243. [Google Scholar] [CrossRef] [PubMed]
  6. Korin, N.; Kanapathipillai, M.; Matthews, B.D.; Crescente, M.; Brill, A.; Mammoto, T.; Ghosh, K.; Jurek, S.; Bencherif, S.A.; Bhatta, D.; et al. Shear-activated nanotherapeutics for drug targeting to obstructed blood vessels. Science 2012, 337, 738–742. [Google Scholar] [CrossRef] [PubMed]
  7. Doig, G.; Yeoh, G.H.; Timchenko, V.; Rosengarten, G.; Barber, T.J.; Cheung, S.C. Simulation of blood flow and nanoparticle transport in a stenosed carotid bifurcation and pseudo-arteriole. J. Comput. Multiph. Flows 2012, 4, 85–101. [Google Scholar] [CrossRef]
  8. Hossain, S.S.; Zhang, Y.; Liang, X.; Hussain, F.; Ferrari, M.; Hughes, T.J.; Decuzzi, P. In silico vascular modeling for personalized nanoparticle delivery. Nanomedicine 2013, 8, 343–357. [Google Scholar] [CrossRef] [PubMed]
  9. Hossain, S.S.; Hughes, T.J.; Decuzzi, P. Vascular deposition patterns for nanoparticles in an inflamed patient-specific arterial tree. Biomech. Model. Mechanobiol. 2014, 13, 585–597. [Google Scholar] [CrossRef] [PubMed]
  10. Chen, H.; Kaminski, M.D.; Pytel, P.; Macdonald, L.; Rosengart, A.J. Capture of magnetic carriers within large arteries using external magnetic fields. J. Drug Target. 2008, 16, 262–268. [Google Scholar] [CrossRef] [PubMed]
  11. Ma, Y.-H.; Wu, S.-Y.; Wu, T.; Chang, Y.-J.; Hua, M.-Y.; Chen, J.-P. Magnetically targeted thrombolysis with recombinant tissue plasminogen activator bound to polyacrylic acid-coated nanoparticles. Biomaterials 2009, 30, 3343–3351. [Google Scholar] [CrossRef] [PubMed]
  12. Matuszak, J.; Lutz, B.; Sekita, A.; Zaloga, J.; Alexiou, C.; Lyer, S.; Cicha, I. Drug delivery to atherosclerotic plaques using superparamagnetic iron oxide nanoparticles. Int. J. Nanomed. 2018, 13, 8443–8460. [Google Scholar] [CrossRef] [PubMed]
  13. Haverkort, J.; Kenjereš, S.; Kleijn, C. Computational simulations of magnetic particle capture in arterial flows. Ann. Biomed. Eng. 2009, 37, 2436–2448. [Google Scholar] [CrossRef] [PubMed]
  14. Gitter, K.; Odenbach, S. Simulation of magnetic drug targeting for a branched artery-model with non-Newtonian flow behaviour of blood. Magnetohydrodynamics 2013, 49, 541–545. [Google Scholar] [CrossRef]
  15. Larimi, M.; Ramiar, A.; Ranjbar, A. Numerical simulation of magnetic nanoparticles targeting in a bifurcation vessel. J. Magn. Magn. Mater. 2014, 362, 58–71. [Google Scholar] [CrossRef]
  16. Lunnoo, T.; Puangmali, T. Capture efficiency of biocompatible magnetic nanoparticles in arterial flow: a computer simulation for magnetic drug targeting. Nanoscale Res. Lett. 2015, 10, 426. [Google Scholar] [CrossRef] [PubMed]
  17. Mahmoodpour, M.; Goharkhah, M.; Ashjaee, M. Investigation on trajectories and capture of magnetic drug carrier nanoparticles after injection into a direct vessel. J. Magn. Magn. Mater. 2020, 497, 166065. [Google Scholar] [CrossRef]
  18. Lee, M.; Shelke, A.; Singh, S.; Fan, J.; Zaleski, P.; Afkhami, S. Numerical simulation of superparamagnetic nanoparticle motion in blood vessels for magnetic drug delivery. Phys. Rev. E 2022, 106, 015104. [Google Scholar] [CrossRef] [PubMed]
  19. Shamloo, A.; Amani, A.; Forouzandehmehr, M.; Ghoytasi, I. In silico study of patient-specific magnetic drug targeting for a coronary LAD atherosclerotic plaque. Int. J. Pharm. 2019, 559, 113–129. [Google Scholar] [CrossRef] [PubMed]
  20. Hewlin, R.L., Jr.; Ciero, A.; Kizito, J.P. Development of a two-way coupled Eulerian–Lagrangian computational magnetic nanoparticle targeting model for pulsatile flow in a patient-specific diseased left carotid bifurcation artery. Cardiovasc. Eng. Technol. 2019, 10, 299–313. [Google Scholar] [CrossRef] [PubMed]
  21. Lindemann, M.C.; Luttke, T.; Nottrodt, N.; Schmitz-Rode, T.; Slabu, I. FEM based simulation of magnetic drug targeting in a multibranched vessel model. Comput. Methods Programs Biomed. 2021, 210, 106354. [Google Scholar] [CrossRef] [PubMed]
  22. Manshadi, M.K.; Saadat, M.; Mohammadi, M.; Shamsi, M.; Dejam, M.; Kamali, R.; Sanati-Nezhad, A. Delivery of magnetic micro/nanoparticles and magnetic-based drug/cargo into arterial flow for targeted therapy. Drug Deliv. 2018, 25, 1963–1973. [Google Scholar] [CrossRef] [PubMed]
  23. Shamloo, A.; Ebrahimi, S.; Ghorbani, G.; Alishiri, M. Targeted drug delivery of magnetic microbubble for abdominal aortic aneurysm: an in silico study. Biomech. Model. Mechanobiol. 2022, 21, 735–753. [Google Scholar] [CrossRef] [PubMed]
  24. Calo, V.; Brasher, N.; Bazilevs, Y.; Hughes, T. Multiphysics model for blood flow and drug transport with application to patient-specific coronary artery flow. Comput. Mech. 2008, 43, 161–177. [Google Scholar] [CrossRef]
  25. Hossain, S.S.; Hossainy, S.F.; Bazilevs, Y.; Calo, V.M.; Hughes, T.J. Mathematical modeling of coupled drug and drug-encapsulated nanoparticle transport in patient-specific coronary artery walls. Comput. Mech. 2012, 49, 213–242. [Google Scholar] [CrossRef]
  26. Xu, Z.; Kleinstreuer, C. Direct nanodrug delivery for tumor targeting subject to shear-augmented diffusion in blood flow. Med. Biol. Eng. Comput. 2018, 56, 1949–1958. [Google Scholar] [CrossRef] [PubMed]
  27. Poonam; Sharma, B.K.; Gandhi, R.; Laroze, D. Simulation of Fe3O4 nanoparticle transport in a diseased curved artery under thermal influence: Implications for targeted drug delivery. Nanomaterials 2026, 16, 677. [Google Scholar] [CrossRef] [PubMed]
  28. Fanelli, C.; Kaouri, K.; Phillips, T.N.; Myers, T.G.; Font, F. Magnetic nanodrug delivery in non-Newtonian blood flows. Microfluid. Nanofluid. 2022, 26, 74. [Google Scholar] [CrossRef]
  29. Lahonian, M.; Khedri, S.; Aminian, S.; Ranjbari, L.; Ardalan, A. Effect of particle–particle and RBC–particle interactions on capture efficiency of magnetic nanocarriers under the influence of a nonuniform magnetic field. Iran. J. Sci. Technol. Trans. Mech. Eng. 2024, 48, 461–474. [Google Scholar] [CrossRef]
  30. Stine, C.A.; Munson, J.M. Convection-enhanced delivery: connection to and impact of interstitial fluid flow. Front. Oncol. 2019, 9, 966. [Google Scholar] [CrossRef] [PubMed]
  31. Sarkar, N.; Roy, S. Periodic flow features in a planar sudden expansion with pulsatile inflow velocity. J. Fluid Mech. 2024, 980, A43. [Google Scholar] [CrossRef]
  32. Khan, M.B.; Sasmal, C. Electro-elastic instability in electroosmotic flows of viscoelastic fluids through a model porous system. Eur. J. Mech. B Fluids 2023, 97, 173–186. [Google Scholar] [CrossRef]
  33. Khan, M.B.; Sasmal, C. Effect of micelle breakage rate on flows of wormlike micellar solutions through pore throats. J. Non-Newton. Fluid Mech. 2022, 307, 104853. [Google Scholar] [CrossRef]
  34. Khan, M.B.; Sasmal, C. Bifurcation in flows of wormlike micellar solutions past three vertically aligned microcylinders in a channel. Phys. Fluids 2022, 34, 054107. [Google Scholar] [CrossRef]
  35. Khan, M.B.; Sasmal, C. Elastic instabilities and bifurcations in flows of wormlike micellar solutions past single and two vertically aligned microcylinders: Effect of blockage and gap ratios. Phys. Fluids 2021, 33, 033109. [Google Scholar] [CrossRef]
  36. Khan, M.B.; Sasmal, C. Effect of chain scission on flow characteristics of wormlike micellar solutions past a confined microfluidic cylinder: A numerical analysis. Soft Matter 2020, 16, 5261–5272. [Google Scholar] [CrossRef] [PubMed]
Figure 1. (a) Two-dimensional geometry of the bifurcating channel with a localized stenosis used in the numerical simulations. All the dimensions are in mm. (b) Computational mesh of the bifurcating channel with localized stenosis. The mesh is refined near the bifurcation and stenosed region to accurately resolve velocity and concentration gradients.
Figure 1. (a) Two-dimensional geometry of the bifurcating channel with a localized stenosis used in the numerical simulations. All the dimensions are in mm. (b) Computational mesh of the bifurcating channel with localized stenosis. The mesh is refined near the bifurcation and stenosed region to accurately resolve velocity and concentration gradients.
Preprints 242100 g001
Figure 2. (a) Magnetic flux density distribution B (T), and (b) corresponding magnetic field gradient ( B · ∇ ) B ( T 2 / m ) profile. The applied magnetic field is 0.5 T in a stenosis region.
Figure 2. (a) Magnetic flux density distribution B (T), and (b) corresponding magnetic field gradient ( B · ∇ ) B ( T 2 / m ) profile. The applied magnetic field is 0.5 T in a stenosis region.
Preprints 242100 g002
Figure 3. Temporal evolution of the velocity magnitude and velocity vectors in the stenosed bifurcating artery under two pulsatile inlet conditions: (a) 1 Hz and (b) 2 Hz. The velocity fields are shown at t = 0.01 , 0.1 , 1, and 10 s .
Figure 3. Temporal evolution of the velocity magnitude and velocity vectors in the stenosed bifurcating artery under two pulsatile inlet conditions: (a) 1 Hz and (b) 2 Hz. The velocity fields are shown at t = 0.01 , 0.1 , 1, and 10 s .
Preprints 242100 g003
Figure 4. Temporal variation of the velocity measured at the center of the inlet and within the stenosed branch (blue dot in inset) for pulsatile inlet frequencies of (a) 1 Hz and (b) 2 Hz.
Figure 4. Temporal variation of the velocity measured at the center of the inlet and within the stenosed branch (blue dot in inset) for pulsatile inlet frequencies of (a) 1 Hz and (b) 2 Hz.
Preprints 242100 g004
Figure 5. Temporal evolution of the magnetic-carrier concentration in the stenosed bifurcating artery for pulsatile inlet frequencies of (a) 1 Hz and (b) 2 Hz at B = 0.50 T .
Figure 5. Temporal evolution of the magnetic-carrier concentration in the stenosed bifurcating artery for pulsatile inlet frequencies of (a) 1 Hz and (b) 2 Hz at B = 0.50 T .
Preprints 242100 g005
Figure 6. Temporal variation of the magnetic carrier concentration within the stenosed target region (blue dot in inset) for pulsatile inlet frequencies of 1 and 2 Hz at B = 0.50 T .
Figure 6. Temporal variation of the magnetic carrier concentration within the stenosed target region (blue dot in inset) for pulsatile inlet frequencies of 1 and 2 Hz at B = 0.50 T .
Preprints 242100 g006
Figure 7. Effect of magnetic field strength on the hemodynamic and carrier concentration fields in the stenosed bifurcating artery for B = 0 , 0.25 , and 0.50 T after 10 s e c at the frequencies of 1 Hz. (a) Velocity magnitude and velocity vectors and (b) corresponding carrier concentration distributions, showing progressively enhanced localization near the stenosed target region with increasing magnetic field strength.
Figure 7. Effect of magnetic field strength on the hemodynamic and carrier concentration fields in the stenosed bifurcating artery for B = 0 , 0.25 , and 0.50 T after 10 s e c at the frequencies of 1 Hz. (a) Velocity magnitude and velocity vectors and (b) corresponding carrier concentration distributions, showing progressively enhanced localization near the stenosed target region with increasing magnetic field strength.
Preprints 242100 g007
Figure 8. Temporal evolution of the magnetic carrier concentration within the stenosed target region for applied magnetic fields of 0, 0.25 , and 0.50 T at the frequencies of 1 Hz.
Figure 8. Temporal evolution of the magnetic carrier concentration within the stenosed target region for applied magnetic fields of 0, 0.25 , and 0.50 T at the frequencies of 1 Hz.
Preprints 242100 g008
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.