Submitted:
03 November 2026
Posted:
04 November 2026
You are already at the latest version
Abstract
Poly(glycidyl methacrylate) (PGMA) polymer composites loaded with 50 wt% metal oxides (ZnO, MoO₃, Cs₂O, HfO₂, and Bi₂O₃) were investigated computationally as lead-free gamma-ray and fast-neutron shielding over 0.015–15 MeV. Phy-X/PSD was used together with an independent Geant4 model of a narrow-beam transmission experiment to perform the calculations. The two approaches agree to 0.56% on average over 168 material–energy combinations, and the model reproduces the full NaI(Tl) pulse-height response. Above 0.1 MeV, the shielding performance improves in the order ZnO/PGMA < MoO₃/PGMA < Cs₂O/PGMA < HfO₂/PGMA < Bi₂O₃/PGMA, whereas below this energy the ranking is governed by the positions of the K absorption edges of the fillers. Bi₂O₃/PGMA is the most effective composite, with a half-value layer of 3.79 cm at 0.662 MeV and an effective atomic number reaching 72.1; it attenuates as effectively as ordinary concrete while requiring about 19% less mass per unit area, and it outperforms reported polyester composites loaded with WO₃ or HgO. The fast-neutron removal cross-sections ΣR lie between 0.0873 and 0.0977 cm⁻¹, above the value for unloaded PGMA in four of the five composites, and per unit mass, all five exceed ordinary concrete, so the neutron and photon rankings differ and HfO₂/PGMA emerges as the balanced choice for mixed fields. These results identify which oxides merit fabrication and provide a validated model against which future transmission measurements can be compared directly.
Keywords:
gamma-ray shielding
; poly(glycidyl methacrylate) (PGMA)
; metal oxides
; polymer composites
; radiation protection
; Geant4 Monte Carlo simulation
; exposure buildup factor
1. Introduction
Ionizing radiation from natural and artificial sources is widely used in medicine, industry, agriculture, space missions, nuclear power plants, and scientific research. Despite these indispensable uses, ionizing radiation can also cause deterministic or stochastic effects on human health (Balasubramanian et al., 2025; Little et al., 2024), so effective shielding materials are needed to protect people and the environment. Designing such material requires considering how the shield interacts with each type of radiation. Fast neutrons are first slowed by heavy elements through inelastic scattering(Khattari, 2025; Oraby et al., 2025; Saxena & Sharma, 2025)Intermediate-energy neutrons are then moderated by elastic scattering with light elements such as hydrogen, the property that makes a hydrogen-rich polymer such as PGMA, with ten hydrogen atoms per C₇H₁₀O₃ repeat unit (7.1 wt%), a natural matrix for a combined gamma–neutron shield. Thermal neutrons are absorbed by elements of high absorption cross-section, such as boron and cadmium (Özcan et al., 2022). Gamma rays and X-rays, in contrast, are attenuated most efficiently by dense, high-atomic-number materials such as lead, tungsten, and bismuth (Yavuzkanat et al., 2026) as also shown for glasses doped with these oxides (Alajerami et al., 2024)(Sayyed et al., 2021). Lead remains the reference shield, but its toxicity, its weight, and its lack of formability have driven a sustained search for lead-free alternatives (Şahmaran & Yavuzkanat, 2026). Polymer composites that combine a hydrogen-rich matrix with high-atomic-number fillers address both requirements at once and have attracted considerable interest as multifunctional shields over the last decade (Abualroos et al., 2024; Bagheri et al., 2024; Filak-Mędoń et al., 2024).
A wide range of matrices - high-density polyethylene, natural rubber, epoxy resin, polyester, polyimide, polystyrene, and poly(vinyl chloride) - has been examined for radiation shielding (Alotaibi et al., 2023; Chaiphaksa et al., 2023; Elsafi et al., 2024; Ghule et al., 2024; Gouda et al., 2024; Khalifa et al., 2024). Poly(glycidyl methacrylate) (PGMA) is a less common but attractive choice for three reasons. First, it is radiation stable in the sense required here: gamma irradiation cross-links the polymer, with formation of conjugated esters and consumption of epoxy groups, rather than degrading it (Borodinov et al., 2015). Second, its pendant epoxy group is chemically reactive and can be opened to graft functional groups or to bond the polymer to inorganic surfaces, as demonstrated for the anion-exchange resins used in radioiodine uptake (Othman et al., 2017) and for the PGMA-graphene oxide nanohybrids prepared by radiation-induced graft polymerization (Nasir et al., 2024). The same chemistry offers a route to coupling a metal oxide filler to the matrix, and hence to the high filler loadings that shielding demands. Third, PGMA is processable from solution and from the melt and self-assembles into films, capsules and particles (Li et al., 2014), so that formable and coatable shields are realistic. Panels of the centimeter thickness required for shielding are accessible by the conventional routes used for methacrylate composites (solvent casting followed by compression or melt molding) rather than by the self-assembly that produces those micro-scale forms. These properties, rather than any established shielding record, motivate the choice of PGMA here.
Many studies report the gamma-ray shielding properties of polymer composites, but most stop at the LAC and MAC. The effective atomic number (), effective electron density (), equivalent atomic number () and the exposure buildup factor are reported less systematically (Elsafi et al., 2024)(Alabsy et al., 2024; Alanazi et al., 2024). Monte Carlo codes such as Geant4, MCNP and FLUKA are widely used to model radiation transport (Agostinelli et al., 2003)(Allison et al., 2016), and offer a flexible and inexpensive route to screening candidate materials before they are synthesized, provided the model itself has been validated (Ahdida et al., 2022; Arce et al., 2021; Freire et al., 2023). The NIST XCOM database is the usual reference for mass attenuation coefficients (Kaşkaş & Şahmaran, 2022).It should be noted, however, that Phy-X/PSD is itself built on XCOM, so that agreement between the two is a consistency check rather than an independent validation, a distinction that several recent database-only studies do not draw (Al-Hadeethi & Sayyed, 2020a, 2020b).
Phy-X/PSD is a widely used implementation of these calculations for composite materials (Şakar et al., 2020)(Acevedo-Del-castillo et al., 2021). From the elemental composition and the density, it returns the LAC, the MAC, and Zeff (Afaneh et al., 2022; Al-Hadeethi & Sayyed, 2020a), and it has been applied to polymers loaded with heavy elements such as lead, tungsten, and barium (Rotkovich et al., 2024). Because the output is resolved in energy, composite formulations can be optimised before synthesis (Al-Hadeethi & Sayyed, 2020b; Mohammed et al., 2024). It also supplies Neff and the EBF needed to describe deep penetration (Alajerami et al., 2024)(Aygün et al., 2020). Together these capabilities make it a practical screening tool for heavy-metal/polymer shields.
The present work investigates PGMA composites loaded with 50 wt% of ZnO, MoO₃, Cs₂O, HfO₂ or Bi₂O₃. The mass attenuation coefficients were computed with Phy-X/PSD and cross-checked against XCOM, and the LAC, MFP, HVL and TVL were derived from them together with the composite densities. An independent Geant4 (v11.2) model of a narrow-beam transmission experiment was built to test those calculations against a different cross-section library and to reproduce the complete detector response. Finally, , , and the EBF were evaluated between 0.015 and 15 MeV, and the fast-neutron removal cross-sections were computed for the same compositions.
The gap addressed by this study is therefore twofold: filled-polymer surveys that stop at database values without an independent check, and rankings quoted at a single energy. Its novelty is threefold. First, the tabulated parameters are validated against an independent Monte Carlo calculation whose photon cross-section library (EPICS2017) is not the one underlying Phy-X/PSD, and the model reproduces the complete NaI(Tl) pulse-height response of a narrow-beam experiment, so future measurements can be compared with it directly. Second, the ranking of the composites is shown to be energy-dependent in a way that is usually overlooked: it follows the filler atomic number only above the K absorption edges, whereas below 0.1 MeV, the range relevant to diagnostic X-rays, it is governed by which K shells are energetically accessible. Third, the gamma-ray analysis is complemented by the fast-neutron removal cross-sections of the same composites, benchmarked against ordinary concrete and lead on an equal-mass basis, so that the multifunctional motivation is quantified rather than merely asserted.
2. Theory: Photon and Neutron Shielding Parameters
2.1. Attenuation Coefficients and Penetration Depths
Under narrow-beam (good-geometry) conditions, the attenuation of a monoenergetic photon beam by an absorbing material follows the Beer–Lambert law, Eq. (1), from which the linear attenuation coefficient (LAC) is obtained (Hannachi et al., 2022; Singh et al., 2022).
where I and I₀ are the transmitted and incident photon intensities, x is the absorber thickness, and is the linear attenuation coefficient.
To evaluate the effectiveness of PGMA composites as photon shielding materials, the mass attenuation coefficient (MAC), defined as the linear attenuation coefficient divided by the density (MAC = LAC/ρ), was obtained for each composite from the mixture rule of Eq. (2):
where represents the weight fraction of the constituent element and (MAC)i its mass attenuation coefficient. The mean free path (MFP), Eq. (3), is the average distance a photon travels between two successive interactions.
The half-value layer (HVL) and the tenth-value layer (TVL) are the absorber thicknesses required to reduce the incident photon intensity to 50% and 10% of its initial value, as determined by Eqs. (4) and (5) (Almuqrin et al., 2024):
2.2. Effective Atomic Number and Electron Density
The effective atomic number () is the atomic number of the single hypothetical element that would attenuate photons in the same way as the composite. It is energy dependent because the relative weight of the photoelectric, Compton, and pair-production channels change with energy. values can be determined using Eq. (6) for the proposed metal oxides/PGMA polymer composites (Akman et al., 2020):
where fi, Ai, and Zi are the fractional molar content, the atomic weight, and the atomic number of the ith element, and the indices i and j both run over all the constituent elements.
The effective electron density (), measured in electrons/g, represents the quantity of electrons per unit mass of the composite material and is calculated using Eq. (7).
where NA is Avogadro's number and is the combined material's mean atomic mass.
2.3. Equivalent Atomic Number and Exposure Buildup Factor
Beyond a few mean free paths, the Beer–Lambert law underestimates the detector response because photons that have been Compton scattered one or more times still reach the detector. The exposure buildup factor (EBF) corrects for this and is defined as the ratio of the total to the uncollided photon response at the point of interest. The EBF of the composites was obtained by the geometric-progression (G-P) fitting method, in three steps (Alabsy & Elzaher, 2023a). The first step is the equivalent atomic number (), the energy-dependent atomic number of the element whose Compton-to-total interaction ratio matches that of the metal oxide/PGMA composite; it is obtained by interpolation between the two neighbouring elements:
where and are the ratios of the elements with atomic numbers and , respectively, and R is the ratio of the composite at the same energy, which lies between R1 and R2.
The calculated values of the composites were then used, in the second step, to interpolate the five G-P exposure buildup factor coefficients (b, c, a, Xk and d) over 0.015–15 MeV with Eq. (9):
where and are the tabulated G-P coefficients of the ANSI/ANS-6.4.3 standard database (Trubey et al., 1991) corresponding to and , respectively, between which the selected composite's lies. Eqs. (8) and (9) are applied independently at each energy of the grid, with no smoothing across the K absorption edges of the fillers; where the equivalent atomic number varies rapidly near an edge, the interpolated coefficients carry their largest uncertainty, which is amplified at large penetration depths. In the third step, the EBF was evaluated from the interpolated geometric-progression (G-P) fitting parameters with Eqs. (10)–(12).
where E is the incident photon energy, x is the penetration depth expressed in mean free paths, b is the value of the buildup factor at one mean free path, and a, c, d, X, and k are the remaining G-P fitting parameters.
2.4. Fast-Neutron Removal Cross-Section
The attenuation of fast neutrons is described by the macroscopic removal cross-section ΣR, the probability per unit path length that a fast neutron is removed from a narrow beam by a first collision. For a mixture, it obeys the same additive rule as the mass attenuation coefficient, Eq. (13), in which (ΣR/ρ)i is the mass removal cross-section of the ith element and Wi its weight fraction. The mass removal cross-sections were taken from the compilation implemented in Phy-X/PSD, and the results are reported both as the macroscopic cross-section ΣR (cm⁻¹) and as the mass value ΣR/ρ (cm²/g), so that materials of different densities can be compared per unit thickness as well as on an equal-mass basis
3. Composite Design and Modeling
PGMA, whose repeat unit is C₇H₁₀O₃, was taken as the matrix and was loaded with ZnO, MoO₃, Cs₂O, HfO₂ or Bi₂O₃ at 50 wt%. Six formulations were considered (Table 1): the unloaded polymer, denoted PGMA, and five composites denoted XO/PGMA, where XO is the metal oxide. The density of each composite was estimated from the inverse rule of mixtures, 1/ρc = w₁/ρ₁ + w₂/ρ₂, using the densities of pure PGMA (1.07 g/cm³) and of the respective metal oxides (“CRC Handbook of Chemistry and Physics,” 2016). At equal weight fraction the composite density follows the density of the oxide rather than the atomic weight of the metal: HfO₂ (9.68 g/cm³) is denser than Bi₂O₃ (8.90 g/cm³), so HfO₂/PGMA is slightly denser than Bi₂O₃/PGMA (1.93 versus 1.91 g/cm³). No void fraction was included in the material definitions, because the porosity of a composite that has not yet been fabricated is unknown. Since porosity leaves the MAC unchanged and simply rescales the density, a porosity p raises the simulated transmission at optical thickness μx by approximately p·μx (about 6% for p = 3% at μx = 2). The tabulated values apply to a real sample once its measured density is inserted. A single, relatively high loading of 50 wt% was adopted for all fillers: it approaches the practical upper limit at which particulate-filled polymers retain acceptable mechanical integrity, and it permits a like-for-like comparison of the five oxides; the effect of graded filler fractions is left for future work.
For input to Phy-X/PSD and to Geant4, the oxide and polymer weight fractions were converted to elemental weight fractions using the PGMA repeat unit C₇H₁₀O₃ (M = 142.15 g/mol) and the stoichiometry of each oxide. Every 50 wt% composite therefore contains C 0.2957 and H 0.0355 by weight, together with O 0.2671 and Zn 0.4017 for ZnO/PGMA, O 0.3355 and Mo 0.3333 for MoO₃/PGMA, O 0.1972 and Cs 0.4716 for Cs₂O/PGMA, O 0.2448 and Hf 0.4240 for HfO₂/PGMA, and O 0.2203 and Bi 0.4485 for Bi₂O₃/PGMA. The same fractions and the densities of Table 1 were used in both codes, so that the two calculations describe identical materials.
4. Geant4 Monte Carlo Model
An independent Monte Carlo model was developed with the Geant4 toolkit (version 11.2) using the emstandard_opt4 electromagnetic physics list, which draws its photon cross-sections from the EPICS2017 evaluation and is therefore independent of the EPDL/XCOM data underlying Phy-X/PSD, following the hybrid Phy-X/PSD–Geant4 methodology reported previously (Alharbi et al., 2026). A production threshold of 0.1 mm was applied to secondary electrons and photons. The narrow-beam geometry is shown in Figure 1: a monoenergetic pencil beam, two lead collimators, the composite absorber of 10 × 10 cm² cross-section, and a 3″×3″ NaI(Tl) scintillation detector. Both collimators are lead cylinders of 5 cm length, 5 cm outer radius, and 5 mm bore radius; the source-side collimator ends 2 cm before the absorber front face, the detector-side collimator 1 cm before the detector housing, and the absorber center lies 20 cm from the crystal front face. The detector-side collimator defines the acceptance angle of the crystal and excludes photons scattered in the absorber, and its stand-off prevents backscatter from the collimator body into the crystal. The energy deposited in the crystal was broadened by a Gaussian whose full width at half maximum follows R(%) = a + b/√(E/MeV) with a = 2.3 and b = 3.8, which gives 7.0% at 0.662 MeV, the value typical of a crystal of this size. For each energy of the XCOM grid between 0.015 and 15 MeV, the absorber thickness was adapted to an optical thickness μx ≈ 2, subject to a practical maximum of 5 cm; this choice minimizes the statistical uncertainty of a transmission measurement, because the relative error of ln(I₀/I) passes through its minimum near μx = 2. With 10⁶ primary photons per run, the statistical uncertainty of each transmission is below 0.3%. The MAC was extracted in two independent ways, from the uncollided-flux (geometric) estimator and from the photopeak-ratio method. Agreement with the database values is quantified throughout by the relative deviation of the mass attenuation coefficient,
5. Results
5.1. Linear and Mass Attenuation Coefficients
Figure 2 shows the LAC of the six materials between 0.015 and 15 MeV, calculated with Phy-X/PSD (a) and simulated with Geant4 (b). The LAC depends on both the photon energy and the metal oxide added: every filler raises it, and the enhancement is largest between 0.015 and 0.25 MeV, the range in which the LAC also falls most steeply with increasing energy. The reason is that photoelectric absorption dominates there, with a cross-section that varies as Z4/E3.5, where Z is the atomic number of the absorbing element, and E is the incident photon energy. (Beni et al., 2018) (Poirier et al., 2020). This is why the highest LAC values are found for Bi₂O₃/PGMA (Z = 83 for Bi) and the lowest for ZnO/PGMA (Z = 30 for Zn). It should be noted that this ordering holds only above the K absorption edges of all fillers (E ≳ 0.1 MeV).Between 0.015 and 0.1 MeV, the ranking depends on which K shells are energetically accessible — for example, at 0.015 MeV the HfO₂/PGMA composite exhibits the highest LAC, whereas below the Mo K-edge (0.020 MeV) MoO₃/PGMA shows the lowest LAC among the loaded composites. Superimposed on this trend are sudden steps in the LAC at 0.0200 MeV for MoO₃/PGMA, 0.0360 MeV for Cs₂O/PGMA, 0.0654 MeV for HfO₂/PGMA, and 0.0905 MeV for Bi₂O₃/PGMA, which are the K absorption edges of Mo, Cs, Hf, and Bi. The Phy-X/PSD and Geant4 curves are nearly indistinguishable over the whole range; the quantitative comparison follows in Section 5.2.
Figure 3 presents the MAC derived from (a) Phy-X/PSD and (b) Geant4, which exhibit the same decreasing trend with photon energy and, apart from the sub-30 keV region discussed below, are almost identical. Between 0.3 and 2 MeV, the MAC decreases gradually and becomes almost independent of the filler, because photoelectric absorption has given way to Compton scattering as the dominant interaction. Compton scattering depends on the electron density per unit mass, which is proportional to the Z/M ratio, where Z represents the atomic number, and M denotes the mass number (Echeweozo et al., 2024)(Hanson et al., 2024). At photon energies where the Compton effect is predominant, the MAC values for all elements are generally similar. Thus, altering the filler type in the PGMA polymer matrix within this energy range does not significantly impact the MAC values. At energies exceeding 2 MeV, the disparity between the MAC values widens again as the photon energy increases, because pair production becomes significant; its cross-section scales approximately as Z² and grows logarithmically with energy well above the 1.022 MeV threshold (Hubbell, 1999).
5.2. Validation Against the Geant4 Model
Figure 2 and Figure 3 compare the LAC and MAC values obtained from Phy-X/PSD (panels a) with those computed by the Geant4 model (panels b) over the entire 0.015–15 MeV range. The agreement between the two independent approaches is excellent: over the 168 material–energy combinations of the scan, the mean absolute relative deviation defined in Eq. (14) is 0.56% (median 0.38%), and at the radionuclide energies of practical interest (0.662, 1.173 and 1.332 MeV) all deviations remain below 0.8% (Table 2). The only systematic departure appears at the lowest energies (15–20 keV), where Geant4 yields MAC values approximately 3% higher than Phy-X/PSD for all six materials (Table 2). This reflects the difference between the EPICS2017 photon cross-section library employed by the emstandard_opt4 physics list and the older EPDL/XCOM data underlying Phy-X/PSD and is consistent with the magnitude of the library differences reported in the literature at sub-30 keV energies.
A second, independent estimate of the attenuation coefficients was obtained from the photopeak-ratio method, which emulates a real NaI(Tl) transmission measurement including the finite energy resolution of the detector. Averaged over all material–energy combinations, this estimator reproduces the database values with a mean |RD| of 0.75%, only marginally larger than the uncollided-flux estimator even though it relies on the full detector response rather than on a direct particle count. These runs also provide a quantitative test of the beam geometry: the ratio of the total crystal response to its uncollided component remains between 0.994 and 1.013 for every material and energy examined, i.e. unity within statistical uncertainty. The collimated arrangement therefore behaves as a true good-geometry experiment, in which scattered photons are effectively excluded from the full-energy peak, and no correction for multiple scattering is required,which is the prerequisite for the attenuation coefficients reported above. The corresponding pulse-height spectra are shown in Figure 4.
Figure 4 shows the simulated NaI(Tl) pulse-height spectra at 0.662 MeV. All characteristic spectroscopic features are faithfully reproduced: the full-energy peak at 662 keV, broadened by the ≈7% energy resolution typical of a 3″×3″ NaI(Tl) crystal, the Compton continuum, its edge at 478 keV, and the valley separating the two. The ordering of the transmitted photopeak intensities follows the attenuation hierarchy established above, Bi₂O₃/PGMA transmitting the fewest primary photons. This complete detector response also accounts for the only two energies at which the photopeak-ratio method departs appreciably from the database values. At 0.020 MeV, exactly at the Mo K absorption edge, the finite resolution smears the discontinuity of the attenuation coefficient over a finite energy window, so that the extracted transmission underestimates the MAC of MoO₃/PGMA by 6%. Above ≈5 MeV, a fraction of the 511 keV annihilation quanta created by pair production inside the crystal escapes before being absorbed, removing counts from the full-energy peak and depressing the photopeak ratio by 2–3%. Both effects are properties of the detector rather than of the shielding material, and both would be present in an equivalent laboratory measurement. The ability to reproduce the complete detector response—rather than integral attenuation coefficients alone—distinguishes the present model from purely database-driven approaches and enables a direct comparison with future experimental spectra.
5.3. Mean Free Path and Half-Value Layer
The MFP, HVL, and TVL translate the attenuation coefficients into thicknesses, which is what a shield designer needs. A smaller MFP means more interactions per unit path and therefore stronger attenuation, while the HVL and TVL are the thicknesses that reduce the incident photon intensity to 50% and 10% of its initial value. A good shielding material has low MFP, HVL, and TVL values (Tekin et al., 2020)(Aşkın, 2020)(Hamad, 2023). Figure 5 shows the MFP (panel a) and HVL (panel b) values as a function of incoming photon energy for the present metal oxide/PGMA composites; the TVL, equal to 3.32 × HVL, exhibits identical behavior and is therefore not plotted. The three quantities differ only by constant factors and therefore behave identically: all increase with photon energy and, at a fixed energy, decrease as the atomic number of the filler increases. PGMA exhibits the highest MFP values, which extend from 0.83 to 51.50 cm. In contrast, the Bi₂O₃/PGMA polymer composite demonstrates the lowest MFP values, ranging from 0.0099 to 14.67 cm at 0.015 MeV and 15 MeV, respectively. At a given photon energy, the three thicknesses decrease in the order PGMA > ZnO/PGMA > MoO₃/PGMA > Cs₂O/PGMA > HfO₂/PGMA > Bi₂O₃/PGMA, with abrupt drops at 0.0200 MeV for MoO₃/PGMA, 0.0360 MeV for Cs₂O/PGMA, 0.0654 MeV for HfO₂/PGMA and 0.0905 MeV for Bi₂O₃/PGMA. These drops are the K absorption edges of Mo, Cs, Hf and Bi, and mirror the steps already seen in the LAC (Alsaab & Zeghib, 2023). Loading the PGMA matrix with a metal oxide therefore reduces all three thicknesses, which is the practical statement of improved shielding.
5.4. Effective Atomic Number and Electron Density
The effective atomic number () and electron density () of the composites were calculated between 0.015 and 15 MeV and are shown in Figure 6(a and b). and were obtained from the MAC of the constituent elements through Eqs. (6) and (7). and depend on both the filler and the photon energy, as seen in Figure 6(a and b). Figure 6(a) shows that for all metal oxide/PGMA composites, decreases sharply as the photon energy increases in the 0.015 to 0.2 MeV energy range. The three regimes mirror the interaction channels already discussed for the attenuation coefficients. The steep fall follows the photoelectric dominance at low energy; between 0.3 and 3 MeV the values remain nearly constant under Compton dominance, and above 3 MeV the gradual rise in the Z_eff values reflects the growth of pair production. . Figure 6(a) also shows that values increase in the following order: PGMA < ZnO/PGMA < MoO₃/PGMA < Cs₂O/PGMA < HfO₂/PGMA < Bi₂O₃/PGMA, at the same photon energy. The maximum is achieved for the Bi₂O₃/PGMA composite, with values ranging from 72.11 to 13.94. The lowest is observed for PGMA, varying from 6.12 to 4.26 within the energy range of 0.015 to 15 MeV, respectively. Figure 6(b) illustrates that is likewise dependent on the energy of the incident photons. The relationship between and the incident photon energy, as well as the type of incorporated metal oxide, follows the same mechanisms discussed above for .
The Geant4 model provides an independent check of these values. Because Zeff is derived from the same photon cross-sections as the MAC, its agreement with the Phy-X/PSD interpolation mirrors that of the attenuation coefficients: the mean absolute deviation over the whole energy grid is 0.65%, and 95% of the points above 0.02 MeV agree to better than 1%. The largest differences, 3.1–3.3%, occur at 0.015 MeV for all six composites and coincide in both sign and magnitude with the sub-30 keV MAC differences discussed above, which confirms that they originate from the cross-section libraries rather than from the Zeff formalism itself. Deviations of this order are typical of Monte-Carlo-versus-database comparisons of shielding materials, (Alabsy & Elzaher, 2023b) the largest deviations are systematically found at the low-energy end of the tabulations and near absorption edges.
5.5. Equivalent Atomic Number
Because the photon interaction cross-sections depend on the atomic number of the medium (Hubbell, 1999), a composite is conveniently characterized by Zeq (Section 2.3). The higher the , the more closely the composite behaves like a high-Z element and the better it shields (Liu et al., 2021). Figure 7 shows as a function of photon energy. The rises to its peak value for all composites at 1 MeV, attributable to the Compton scattering process. The decrease occurs rapidly when photon energy surpasses 1 MeV, attributed to the pair production process. Adding a metal oxide raises at equivalent photon energy levels. The Bi₂O₃/PGMA composite exhibited the highest , whereas the PGMA composite recorded the lowest . The K absorption edges of Cs, Hf, and Bi yield three distinct peaks in the values: 0.0360 MeV for Cs₂O/PGMA, 0.0654 MeV for HfO₂/PGMA, and 0.0905 MeV for Bi₂O₃/PGMA composites. The Bi₂O₃/PGMA composite therefore ranks first on this measure as well, in agreement with its LAC, MFP, and Zeff behavior.
5.6. Exposure Buildup Factor
A shield more than a few mean free paths thick cannot be designed from the attenuation coefficients alone, because repeatedly scattered photons add to the response; this is what the exposure buildup factor (EBF) accounts for (Basu et al., 2021)(Turhan et al., 2022). Because scattered photons can only add to the uncollided response, the EBF is always greater than unity (Harima, 1993). It was evaluated from Eqs. (10)–(12) between 0.015 and 15 MeV at penetration depths of 1, 5, 10, 20, 30, and 40 MFP (1, 5, 10, and 15 MFP in panels d and f), as shown in Figure 8 (a, b, c, d, e, and f). PGMA, ZnO/PGMA and MoO₃/PGMA follow the same pattern with photon energy, Figure 8 (a, b, and c). At moderate photon energies between 0.08 and 1.9 MeV, where secondary photons are produced by Compton scattering without being fully absorbed, the EBF values reach their maximum, and they continue to grow with depth owing to multiple scattering (Lokhande et al., 2021). Conversely, for both low and high photon energies, the EBF values are much lower than those at intermediate energies. This pattern arises from the dominance of the photoelectric effect and pair-production processes, whereby photons are either completely absorbed or strongly degraded in energy in the low- and high-energy regions (Bantan et al., 2020)(Kolavekar et al., 2022). Contrary to the previous trend, the EBF values for Cs₂O/PGMA, HfO₂/PGMA, and Bi₂O₃/PGMA exhibit additional structure at low energies. At depths of up to 10 MFP, this structure follows the K absorption edges of Cs, Hf, and Bi, respectively, and remains modest in magnitude (EBF ≤ 4.4 at 5 MFP). For every composite, the EBF rises with penetration depth from 1 to 40 MFP, because more interactions generate more secondary photons.
Beyond about 15 MFP the G-P output for Cs₂O/PGMA and Bi₂O₃/PGMA develops narrow, unphysical spikes; panels (d) and (f) of Figure 8 are therefore truncated at 15 mfp, and the origin of these spikes deserves comment, because they are frequently reproduced without discussion. They do not coincide with any absorption edge—for Cs₂O/PGMA the spike lies at 0.06 MeV whereas the Cs K edge is at 0.036 MeV, and for Bi₂O₃/PGMA the two spikes lie at 0.02 and 0.06 MeV whereas the Bi K edge is at 0.0905 MeV—and they are absent at moderate depths. For Cs₂O/PGMA at 0.06 MeV the EBF grows smoothly from 1.95 at 0.5 MFP to 4.18 at 10 MFP, then to 2.6 × 10² at 20 MFP and 1.2 × 10¹⁴ at 40 MFP. This runaway behavior is a property of the G-P function itself, Eq. (10): when the interpolated parameters yield K(E, x) > 1, the term Kx grows exponentially with depth, so that small uncertainties in the fitted coefficients—largest where Z_eq varies rapidly between the tabulated elements—are amplified without bound. The G-P values for the Cs- and Bi-loaded composites should therefore be regarded as quantitative only up to roughly 15 MFP, which comfortably covers the range of practical shield thicknesses and the range validated against Geant4 below.
5.7. Fast-Neutron Removal Cross-Section
The fast-neutron removal cross-sections computed from Eq. (13) are shown in Figure 9, per unit thickness in panel (a) and per unit mass in panel (b). Per unit mass, the unloaded polymer is by far the best fast-neutron attenuator of the series (ΣR/ρ = 0.0858 cm²/g), because the removal power resides almost entirely in its hydrogen. Replacing half of the matrix by a heavy oxide, whose own mass removal cross-section is small (0.0134–0.0236 cm²/g for the pure oxides), lowers ΣR/ρ of every composite to 0.0496–0.0547 cm²/g. Per unit thickness, the higher density of the composites almost exactly compensates this dilution, so four of the five composites slightly exceed the unloaded polymer: HfO₂/PGMA (0.0977 cm⁻¹) and ZnO/PGMA (0.0974 cm⁻¹) give the largest values against 0.0918 cm⁻¹ for PGMA. The best gamma-ray absorber, Bi₂O₃/PGMA (0.0947 cm⁻¹), ranks only fourth and Cs₂O/PGMA is lowest (0.0873 cm⁻¹), its oxide combining the lowest density of the series with a very small mass removal cross-section. For reference, ordinary concrete gives ΣR = 0.0936 cm⁻¹ and ΣR/ρ = 0.0407 cm²/g, so on an equal-mass basis every composite exceeds concrete for fast neutrons as well (Table 3). The gamma-ray and fast-neutron rankings therefore do not coincide, which is taken up in the Discussion.
6. Discussion
The combined results allow a consistent picture of the shielding hierarchy. Above ≈0.1 MeV, where the K shells of all fillers are accessible, the attenuation ranking follows the filler atomic number, and Bi₂O₃/PGMA is uniformly the best performer: at 0.662 MeV its HVL (3.79 cm) is roughly half that of pure PGMA (7.84 cm), and similar factors hold for the MFP and TVL. Below 0.1 MeV the ranking is instead governed by the positions of the K absorption edges, so HfO₂/PGMA locally outperforms Bi₂O₃/PGMA between the Hf and Bi K-edges, and ZnO/PGMA outperforms the Mo- and Cs-loaded composites below 0.020 MeV. For applications dominated by diagnostic X-ray energies, this sub-edge behavior, rather than the high-energy ranking, dictates the optimum filler.
To place the present composites in a broader context, Table 3 compares their HVL at 0.662 MeV, together with their fast-neutron mass removal cross-sections, with recently reported filled polymers and with reference materials evaluated with the same computational approach. Bi₂O₃/PGMA (HVL = 3.79 cm at 1.91 g/cm³) attenuates as effectively as ordinary concrete (3.87 cm at 2.30 g/cm³) while requiring about 19% less mass per unit area (7.2 vs 8.9 g/cm² per HVL), it also attenuates more strongly than recently reported polyester composites loaded with 15 wt% WO₃ (5.63 cm) (Isazadeh & Saray, 2025) or 15 wt% HgO (5.17 cm) (Zebardast & Saray, 2025). Both composites have a much lower filler loading (15 vs. 50 wt%), so the comparison concerns the thickness achieved rather than the filler's efficiency. Lead remains about seven times thinner (0.55 cm), but the PGMA composites offer the usual advantages of a lead-free, light and formable shield.
Taken together, the photon and neutron results point in different directions, and this is the practical message of the comparison. Bi₂O₃/PGMA is the best gamma-ray shield of the series on every photon metric, yet it ranks only fourth for fast-neutron removal, whereas HfO₂/PGMA is close to the best on both counts and is therefore the more balanced choice for a mixed field. Because the removal power per unit mass resides almost entirely in the hydrogen of the matrix, raising the filler fraction beyond 50 wt% would improve the photon performance at the expense of the neutron performance; at 50 wt% the composites already give up some 40% of the polymer’s ΣR/ρ, although their higher density restores the balance per unit thickness. Under the weight additivity of Eq. (13), ΣR/ρ falls linearly with filler fraction and reaches half of the unloaded-polymer value near 60 wt% (0.043 cm²/g for Bi₂O₃/PGMA); per unit thickness, ideal void-free densification continues to compensate, so in practice the loading limit is set by porosity and mechanical integrity rather than by ΣR itself. The data reported here allow that trade-off to be quantified rather than guessed. The equal-mass comparison with concrete also extends to neutrons: with ΣR/ρ = 0.0496–0.0547 cm²/g against 0.0407 cm²/g for ordinary concrete, the composites keep their mass advantage in a mixed gamma–neutron field.
Finally, some limitations should be kept in mind. The densities adopted here follow the inverse rule of mixtures and therefore assume fully dense, agglomerate-free composites; real filled polymers typically exhibit a few percent porosity, which would reduce the LAC proportionally while leaving the MAC unchanged. Cs₂O is included as a representative intermediate-Z oxide, although its strong hygroscopicity makes practical processing difficult. A practical mitigation would exploit the epoxy groups of PGMA itself: ring-opening at the particle surface can graft the matrix onto the filler and cross-link a moisture-barrier shell around it, and pre-coating the oxide with a thin silane or polymer layer before compounding would serve the same purpose.The Geant4 model was validated against evaluated cross-section data rather than against measurements, so that the agreement reported here establishes the internal consistency of the transport calculation rather than its experimental accuracy. The G-P buildup factors are quoted in their tabulated form, which refers to a point isotropic source in an infinite medium; transferring them to a finite slab viewed by a finite detector is not straightforward and is left to a dedicated study. Experimental transmission measurements on fabricated samples, following the narrow-beam geometry of Figure 1, are the next natural step and can be compared directly with the present predictions.
7. Conclusions
PGMA composites loaded with 50 wt% ZnO, MoO₃, Cs₂O, HfO₂ or Bi₂O₃ were evaluated as lead-free gamma-ray and fast-neutron shields, with three main outcomes. First, the methodology is validated: the Geant4 model reproduces the Phy-X/PSD values to 0.56% on average over 168 material–energy combinations (the only systematic departure, a 3% offset below 30 keV, follows from the cross-section libraries, not from the model). It also reproduces the full NaI(Tl) pulse-height response, so measured spectra can be compared with it directly once the composites are made. Second, the ranking is energy dependent: above the K absorption edges Bi₂O₃/PGMA is the best photon shield, with an HVL at 0.662 MeV of 3.79 cm against 7.84 cm for the unloaded polymer, while below 0.1 MeV the edges reverse the order. For fast neutrons ΣR lies between 0.0873 and 0.0977 cm⁻¹ with HfO₂/PGMA and ZnO/PGMA leading and Bi₂O₃/PGMA only fourth, so a shield for a mixed field must balance the two rankings, and HfO₂/PGMA is the better compromise. Third, the practical case: on an equal-mass basis Bi₂O₃/PGMA matches ordinary concrete at 0.662 MeV with about 19% less mass per unit area, and per unit mass every composite also exceeds concrete for fast-neutron removal. The main limitations are the ideal void-free densities and the G-P buildup factors, which diverge beyond about 15 mfp for the Cs- and Bi-loaded composites; deeper penetrations call for discrete-ordinates or Monte Carlo transport. Fabricating the composites and measuring their transmission in the geometry modelled here is the natural next step, and achieving a uniform 50 wt% loading will itself demand attention to particle dispersion, agglomeration and the mechanical integrity of the highly filled matrix.
Data Availability Statement
The datasets generated and analyzed during the current study (Phy-X/PSD exports, Geant4 input macros, and simulation outputs) are available from the corresponding author upon reasonable request.
Acknowledgments
The authors would like to extend their sincere appreciation to the Ongoing Research Funding Program (ORF-2026-1608), King Saud University, Riyadh, Saudi Arabia, for funding this work.
Conflicts of Interest
The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
References
- Abualroos, N. J.; Idris, M. I.; Ibrahim, H.; Kamaruzaman, M. I.; Zainon, R. Physical, mechanical, and microstructural characterization of tungsten carbide-based polymeric composites for radiation shielding application. Sci. Rep. 2024, 14(1), 1–17. [Google Scholar] [CrossRef] [PubMed]
- Acevedo-Del-castillo, A.; Águila-Toledo, E.; Maldonado-Magnere, S.; Aguilar-Bolados, H. A Brief Review on the High-Energy Electromagnetic Radiation-Shielding Materials Based on Polymer Nanocomposites. Int. J. Mol. Sci. 2021, Vol. 22(Page 9079, 22(16)), 9079. [Google Scholar] [CrossRef] [PubMed]
- Afaneh, F.; Khattari, Z. Y.; Al-Buriahi, M. S. Monte Carlo simulations and phy-X/PSD study of radiation shielding and elastic effects of molybdenum and tungsten in phosphate glasses. J. Mater. Res. Technol. 2022, 19, 3788–3802. [Google Scholar] [CrossRef]
- Agostinelli, S.; Allison, J.; Amako, K.; Apostolakis, J.; Araujo, H.; Arce, P.; Asai, M.; Axen, D.; Banerjee, S.; Barrand, G.; Behner, F.; Bellagamba, L.; Boudreau, J.; Broglia, L.; Brunengo, A.; Burkhardt, H.; Chauvie, S.; Chuma, J.; Chytracek, R.; …; Zschiesche, D. Geant4—a simulation toolkit. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 2003, 506(3), 250–303. [Google Scholar] [CrossRef]
- Ahdida, C.; Bozzato, D.; Calzolari, D.; Cerutti, F.; Charitonidis, N.; Cimmino, A.; Coronetti, A.; D’Alessandro, G. L.; Donadon Servelle, A.; Esposito, L. S.; Froeschl, R.; García Alía, R.; Gerbershagen, A.; Gilardoni, S.; Horváth, D.; Hugo, G.; Infantino, A.; Kouskoura, V.; Lechner, A.; …; Widorski, M. New Capabilities of the FLUKA Multi-Purpose Code. Front. Phys. 2022, 9, 788253. [Google Scholar] [CrossRef]
- Akman, F.; Kaçal, M. R.; Almousa, N.; Sayyed, M. I.; Polat, H. Gamma-ray attenuation parameters for polymer composites reinforced with BaTiO3 and CaWO4 compounds. Prog. Nucl. Energy 2020, 121, 103257. [Google Scholar] [CrossRef]
- Alabsy, M. T.; Abbas, M. I.; El-khatib, A. Y.; El-Khatib, A. M. Attenuation properties of poly methyl methacrylate reinforced with micro/nano ZrO2 as gamma-ray shields. Sci. Rep. 2024, 14(1), 1–18. [Google Scholar] [CrossRef] [PubMed]
- Alabsy, M. T.; Elzaher, M. A. Radiation shielding performance of metal oxides/EPDM rubber composites using Geant4 simulation and computational study. Sci. Rep. 2023a, 13(1), 1–13. [Google Scholar] [CrossRef] [PubMed]
- Alabsy, M. T.; Elzaher, M. A. Radiation shielding performance of metal oxides/EPDM rubber composites using Geant4 simulation and computational study. Sci. Rep. 2023b, 13(1). [Google Scholar] [CrossRef] [PubMed]
- Alajerami, Y. S.; Mhareb, M. H. A.; Sayyed, M. I.; Hamad, M. K.; Kodeh, F.; Rashad, M.; Mitwalli, M. Comprehensive study for radiation shielding features for Bi2O3–B2O3–ZnO composite using computational radioanalytical Phy-X/PSD, MCNP5, and SRIM software. Sci. Rep. 2024, 14:1(14(1)), 1–13. [Google Scholar] [CrossRef] [PubMed]
- Alanazi, S. F.; Alotaibi, N. M.; Alsuhybani, M.; Alnassar, N.; Almasoud, F. I.; Almurayshid, M. Fabrication, Structural Characterization, and Photon Attenuation Efficiency Investigation of Polymer-Based Composites. Polymers 2024, Vol. 16(Page 1212, 16(9)), 1212. [Google Scholar] [CrossRef] [PubMed]
- Al-Hadeethi, Y.; Sayyed, M. I. Evaluation of gamma ray shielding characteristics of CaF2–BaO –P2O5 glass system using Phy-X / PSD computer program. Prog. Nucl. Energy 2020a, 126, 103397. [Google Scholar] [CrossRef]
- Al-Hadeethi, Y.; Sayyed, M. I. Using Phy-X/PSD to investigate gamma photons in SeO2–Ag2O–TeO2 glass systems for shielding applications. Ceram. Int. 2020b, 46(8), 12416–12421. [Google Scholar] [CrossRef]
- Alharbi, A.; Asemi, N. N.; Alnagran, H. Hybrid Phy-X/PSD–Geant4 Assessment of Gamma and Neutron Shielding in Lead-Free HDPE Composites Reinforced with High-Z Oxides. Polymers 2026, Vol. 18(Page 179, 18(2)), 179. [Google Scholar] [CrossRef] [PubMed]
- Allison, J.; Amako, K.; Apostolakis, J.; Arce, P.; Asai, M.; Aso, T.; Bagli, E.; Bagulya, A.; Banerjee, S.; Barrand, G.; Beck, B. R.; Bogdanov, A. G.; Brandt, D.; Brown, J. M. C.; Burkhardt, H.; Canal, P.; Cano-Ott, D.; Chauvie, S.; Cho, K.; …; Yoshida, H. Recent developments in Geant4. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 2016, 835, 186–225. [Google Scholar] [CrossRef]
- Almuqrin, A. H.; Sayyed, M. I.; Alorain, D. A.; Elsafi, M. Multilayer radiation shields for nuclear and radiological centers using free-lead materials and nanoparticles. Ann. Nucl. Energy 2024, 200, 110404. [Google Scholar] [CrossRef]
- Alotaibi, R.; Cerdà, J. J.; Akhdar, H.; Alotaibi, R. Geant4 Simulation of the Effect of Different Composites on Polyimide Photon and Neutron Shielding Properties. Polymers 2023, Vol. 15(Page 1973, 15(8)), 1973. [Google Scholar] [CrossRef] [PubMed]
- Alsaab, A. H.; Zeghib, S. Study of Prepared Lead-Free Polymer Nanocomposites for X- and Gamma-ray Shielding in Healthcare Applications. Polymers 2023, 15(9), 2142. [Google Scholar] [CrossRef]
- Arce, P.; Bolst, D.; Bordage, M. C.; Brown, J. M. C.; Cirrone, P.; Cortés-Giraldo, M. A.; Cutajar, D.; Cuttone, G.; Desorgher, L.; Dondero, P.; Dotti, A.; Faddegon, B.; Fedon, C.; Guatelli, S.; Incerti, S.; Ivanchenko, V.; Konstantinov, D.; Kyriakou, I.; Latyshev, G.; …; Wright, D. H. Report on G4-Med, a Geant4 benchmarking system for medical physics applications developed by the Geant4 Medical Simulation Benchmarking Group. Med. Phys. 2021, 48(1), 19–56. [Google Scholar] [CrossRef] [PubMed]
- Aşkın, A. Evaluation of the radiation shielding capabilities of the Na2B4O7–SiO2–MoO3-Dy2O3 glass quaternary using Geant4 simulation code and Phy-X/PSD database. Ceram. Int. 2020, 46(7), 9096–9102. [Google Scholar] [CrossRef]
- Aygün, B.; Şakar, E.; Singh, V. P.; Sayyed, M. I.; Korkut, T.; Karabulut, A. Experimental and Monte Carlo simulation study on potential new composite materials to moderate neutron-gamma radiation. Prog. Nucl. Energy 2020, 130, 103538. [Google Scholar] [CrossRef]
- Bagheri, S.; Khalafi, H.; Tohidifar, M. R.; Bagheri, S. Thermoplastic and thermoset polymer matrix composites reinforced with bismuth oxide as radiation shielding materials. Compos. Part B Eng. 2024, 278, 111443. [Google Scholar] [CrossRef]
- Balasubramanian, D.; Agraharam, G.; Girigoswami, A.; Girigoswami, K. Multiple radiations and its effect on biological system–a review on in vitro and in vivo mechanisms. Ann. Med. 2025, 57(1), 2486595. [Google Scholar] [CrossRef] [PubMed]
- Bantan, R. A. R.; Sayyed, M. I.; Mahmoud, K. A.; Al-Hadeethi, Y. Application of experimental measurements, Monte Carlo simulation and theoretical calculation to estimate the gamma ray shielding capacity of various natural rocks. Prog. Nucl. Energy 2020, 126, 103405. [Google Scholar] [CrossRef]
- Basu, P.; Sarangapani, R.; Venkatraman, B. An improvement to the Kalos’ formula for double layer gamma ray exposure buildup factors for shielding materials of nuclear and radiological facilities. Ann. Nucl. Energy 2021, 151, 107944. [Google Scholar] [CrossRef]
- Beni, M. S.; Krstic, D.; Nikezic, D.; Yu, K. N. Monte Carlo studies on photon interactions in radiobiological experiments. PLoS ONE 2018, 13(3), e0193575. [Google Scholar] [CrossRef] [PubMed]
- Borodinov, N.; Giammarco, J.; Patel, N.; Agarwal, A.; O’Donnell, K. R.; Kucera, C. J.; Jacobsohn, L. G.; Luzinov, I. Stability of Grafted Polymer Nanoscale Films toward Gamma Irradiation. ACS Appl. Mater. Interfaces 2015, 7(34), 19455–19465. [Google Scholar] [CrossRef]
- Chaiphaksa, W.; Yonphan, S.; Kalkornsurapranee, E.; Tuljittraporn, A.; Kothan, S.; Kaewjaeng, S.; Kedkaew, C.; Kaewkhao, J. Photon, charged particles, and neutron shielding properties of natural rubber/ SnO2 composites. Radiat. Phys. Chem. 2023, 203, 110622. [Google Scholar] [CrossRef]
- Echeweozo, E. O.; Alomairy, S.; Alsaiari, N. S.; Al-Buriahi, M. S. Effect of lead oxide addition on gamma radiation shielding properties of newly developed geopolymers: theoretical and simulation studies. Sci. Rep. 2024, 14(1), 1–13. [Google Scholar] [CrossRef] [PubMed]
- Elsafi, M.; Abdel-Gawad, E. H.; El-Nahal, M. A.; Sayyed, M. I. Effect of tin oxide particle size on epoxy resin to form new composites against gamma radiation. Sci. Rep. 2024, 14(1), 1–10. [Google Scholar] [CrossRef] [PubMed]
- Filak-Mędoń, K.; Fornalski, K. W.; Bonczyk, M.; Jakubowska, A.; Kempny, K.; Wołoszczuk, K.; Filipczak, K.; Żerańska, K.; Zdrojek, M. Graphene-based nanocomposites as gamma- and X-ray radiation shield. Sci. Rep. 2024, 14(1), 1–8. [Google Scholar] [CrossRef] [PubMed]
- Freire, J. J.; Vlahos, C. H.; Akhdar, H.; Alshehri, M. Geant4 Simulation of Photon- and Neutron-Shielding Capabilities of Biopolymer Blends of Poly(lactic acid) and Poly(hydroxybutyrate). Polymers 2023, Vol. 15(Page 4257, 15(21)), 4257. [Google Scholar] [CrossRef] [PubMed]
- Ghule, P. G.; Bholane, G. T.; Joshi, R. P.; Dahiwale, S. S.; Shelke, P. N.; Dhole, S. D. Gamma radiation shielding properties of unsaturated polyester /Bi2O3 composites: An experimental, theoretical and simulation approach. Radiat. Phys. Chem. 2024, 216, 111452. [Google Scholar] [CrossRef]
- Gouda, M. M.; Osman, A. F.; Awad, R.; Badawi, M. S. Enhanced radiation shielding efficiency of polystyrene nanocomposites with tailored lead oxide nanoparticles. Sci. Rep. 2024, 14(1), 1–13. [Google Scholar] [CrossRef] [PubMed]
- Hamad, M. K. Evaluation of photon shielding properties for new refractory tantalum-rich sulfides Ta9(XS3)2 alloys: A study with the MCNP-5. Ann. Nucl. Energy 2023, 184, 109687. [Google Scholar] [CrossRef]
- Hannachi, E.; Sayyed, M. I.; Slimani, Y.; Almessiere, M. A.; Baykal, A.; Elsafi, M. Synthesis, characterization, and performance assessment of new composite ceramics towards radiation shielding applications. J. Alloys Compd. 2022, 899, 163173. [Google Scholar] [CrossRef]
- Hanson, S. C.; Xiao, Y.; Charrette, R.; Hayes, R. B. A preliminary NASA compliant conformal coating for optimized space radiation shielding configurations and its mass attenuation coefficients. Prog. Nucl. Energy 2024, 169, 105089. [Google Scholar] [CrossRef]
- Harima, Y. An historical review and current status of buildup factor calculations and applications. Radiat. Phys. Chem. 1993, 41(4–5), 631–672. [Google Scholar] [CrossRef]
- Hubbell, J. H. Review of photon interaction cross section data in the medical and biological context. Phys. Med. Biol. 1999, 44(1), R1. [Google Scholar] [CrossRef] [PubMed]
- Isazadeh, F.; Saray, A. A. Experimental and simulation assessment of gamma-radiation shielding properties of the polyester polymer reinforced with WO3. Sci. Rep. 2025, 2025 15:1(15(1)), 37145. [Google Scholar] [CrossRef] [PubMed]
- Kaşkaş, A.; Şahmaran, T. Determination of the radiological properties of materials: A new approximation method for calculation of the mass attenuation coefficients. Appl. Radiat. Isot. 2022, 187, 110340. [Google Scholar] [CrossRef] [PubMed]
- Kebaili, I.; Boukhris, I.; Sayyed, M. I. Gamma-ray shielding properties of lead borovanadate glasses. Ceram. Int. 2020, 46(11), 19624–19628. [Google Scholar] [CrossRef]
- Khalifa, M.; El Sayed, A. M.; Kassem, S. M.; Tarek, E. Synthesis, structural, optical, and thermal properties of LaFeO3/Poly(methyl methacrylate)/Poly(vinyl acetate) nanocomposites for radiation shielding. Sci. Rep. 2024, 14(1), 1–17. [Google Scholar] [CrossRef] [PubMed]
- Khattari, Z. Y. Tailoring structural and compositional influence on γ-ray shielding efficiency of Zeolite frameworks. J. Am. Ceram. Soc. 2025, 108(8), e20560. [Google Scholar] [CrossRef]
- Kolavekar, S. B.; Hiremath, G. B.; Patil, P. N.; Badiger, N. M.; Ayachit, N. H. Investigation of gamma-ray shielding parameters of bismuth phospho-tellurite glasses doped with varying Sm2O3. Heliyon 2022, 8(11), e11788. [Google Scholar] [CrossRef] [PubMed]
- Li, Q. L.; Gu, W. X.; Gao, H.; Yang, Y. W. Self-assembly and applications of poly(glycidyl methacrylate)s and their derivatives. Chem. Commun. 2014, 50(87), 13201–13215. [Google Scholar] [CrossRef] [PubMed]
- Little, M. P.; Bazyka, D.; de Gonzalez, A. B.; Brenner, A. V.; Chumak, V. V.; Cullings, H. M.; Daniels, R. D.; French, B.; Grant, E.; Hamada, N.; Hauptmann, M.; Kendall, G. M.; Laurier, D.; Lee, C.; Lee, W. J.; Linet, M. S.; Mabuchi, K.; Morton, L. M.; Muirhead, C. R.; …; Zablotska, L. B. A Historical Survey of Key Epidemiological Studies of Ionizing Radiation Exposure. Https //Doi.Org/10.1667/RADE-24-00021.1 2024, 202(2), 432–487. [Google Scholar] [CrossRef] [PubMed]
- Liu, T.; Hong, G.; Cai, W. A comparative study of effective atomic number calculations for dual-energy CT. Med. Phys. 2021, 48(10), 5908–5923. [Google Scholar] [CrossRef] [PubMed]
- Lokhande, R. M.; Vinayak, V.; Mukhamale, S. V.; Khirade, P. P. Gamma radiation shielding characteristics of various spinel ferrite nanocrystals: a combined experimental and theoretical investigation. RSC Adv. 2021, 11(14), 7925–7937. [Google Scholar] [CrossRef] [PubMed]
- Mohammed, M. I.; Yahia, I. S.; Zahran, H. Y. Radiation attenuation parameters of Ti3SiC2 MAX phase and their binary compounds using Phy-X/PSD software. Mater. Sci. Semicond. Process. 2024, 169, 107916. [Google Scholar] [CrossRef]
- Nasir, A.; Sadiq, A.; Saleem, F.; Mumtaz, S.; Yasin, T. Radiation Induced Graft Polymerization of Glycidyl Methacrylate on Graphene Oxide. Int. J. Phys. Mater. Sci. 2024, 1(02). [Google Scholar] [CrossRef]
- Oraby, H.; Hegazy, G. E.; ElTalawy, S. M.; Nabil, I. M. Polyurethane-based foam composites: synthesis, structural characteristics, and radiation shielding properties. Sci. Rep. 2025, 15(1), 1–16. [Google Scholar] [CrossRef] [PubMed]
- Othman, S. H.; Elbarbary, A. M.; Rashad, G.; Fasih, T. W. Radio-iodide uptake by modified poly (glycidyl methacrylate) as anion exchange resin. Radiochim. Acta 2017, 105(1), 75–84. [Google Scholar] [CrossRef]
- Özcan, M.; Kam, E.; Kaya, C.; Kaya, F. Boron-containing nonwoven polymeric nanofiber mats as neutron shields in compact nuclear fusion reactors. Int. J. Energy Res. 2022, 46(6), 7441–7450. [Google Scholar] [CrossRef]
- Poirier, Y.; Belley, M. D.; Dewhirst, M. W.; Yoshizumic, T. T.; Down, J. D. Transitioning from Gamma Rays to X Rays for Comparable Biomedical Research Irradiations: Energy Matters. 2020, 193(6), 506–511. [Google Scholar] [CrossRef] [PubMed]
- Poltabtim, W.; Toyen, D.; Saenboonruang, K. Theoretical Determination of High-Energy Photon Attenuation and Recommended Protective Filler Contents for Flexible and Enhanced Dimensionally Stable Wood/NR and NR Composites. Polymers 2021, Vol. 13(Page 869, 13(6)), 869. [Google Scholar] [CrossRef] [PubMed]
- Romanelli, G.; Capuani, S.; Onorati, D.; Ulpiani, P.; Preziosi, E.; Andreani, C.; Senesi, R. Fluorinated borono-phenylalanine for optimizing BNCT: Enhancing boron absorption against hydrogen scattering for thermal neutrons. Med. Phys. 2024, 51(1), 439–446. [Google Scholar] [CrossRef] [PubMed]
- Rotkovich, A. A.; Tishkevich, D. I.; Razanau, I. U.; Vershinina, T. N.; Bondaruk, A. A.; German, S. A.; Zubar, T. I.; Sayyed, M. I.; Dong, M.; Yao, Y.; Mahmoud, K. A.; Silibin, M. V.; Trukhanov, A. V. Development and study of lightweight recycled composite materials based on linear low-density polyethylene and W for radiation application. J. Mater. Res. Technol. 2024, 30, 1310–1318. [Google Scholar] [CrossRef]
- Şahmaran, T.; Yavuzkanat, N. Effect of Fe2O3 on the radiation shielding efficiency of B2O3-SiO2-Li2O glasses. Radiat. Phys. Chem. 2026, 239, 113354. [Google Scholar] [CrossRef]
- Şakar, E.; Özpolat, Ö. F.; Alım, B.; Sayyed, M. I.; Kurudirek, M. Phy-X / PSD: Development of a user friendly online software for calculation of parameters relevant to radiation shielding and dosimetry. Radiat. Phys. Chem. 2020, 166, 108496. [Google Scholar] [CrossRef]
- Saxena, S.; Sharma, H. Prediction and assessment of optimal concrete compositions for overall radiation protection and reduced global warming potential. Sci. Rep. 2025, 15(1), 1–25. [Google Scholar] [CrossRef] [PubMed]
- Sayyed, M. I.; Mahmoud, K. A.; Lacomme, E.; AlShammari, M. M.; Dwaikat, N.; Alajerami, Y. S. M.; Alqahtani, M.; El-bashir, B. O.; Mhareb, M. H. A. Development of a novel MoO3-doped borate glass network for gamma-ray shielding applications. Eur. Phys. J. Plus 2021, 136:1(136(1)), 108. [Google Scholar] [CrossRef]
- Singh, S.; Kaur, R.; Rani, S.; Sidhu, B. S. Physical, structural and nuclear radiation shielding behaviour of xBaO-(0.30-x)MgO-0.10Na2O-0.10Al2O3-0.50B2O3 glass matrix. Mater. Chem. Phys. 2022, 276, 125415. [Google Scholar] [CrossRef]
- Stamatopoulos, A.; Koehler, P. E.; Digiovine, B.; Mocko, V.; Matyskin, A.; Vermeulen, C.; Couture, A.; Cooper, A.; Morrell, J.; O’Brien, E. Discovery of the Origin of the Enormous Zr 88 Neutron-Capture Cross Section and Quantifying Its Impact on Applications. Phys. Rev. Lett. 2025, 134(11), 112702. [Google Scholar] [CrossRef]
- Tekin, H. O.; Kaçal, M. R.; Issa, S. A. M.; Polat, H.; Susoy, G.; Akman, F.; Kilicoglu, O.; Gillette, V. H. Sodium dodecatungstophosphate hydrate-filled polymer composites for nuclear radiation shielding. Mater. Chem. Phys. 2020, 256, 123667. [Google Scholar] [CrossRef]
- Trubey, D. K.; Eisenhauer, C. M.; Foderaro, A.; Gopinath, D. V.; Harima, Y.; Hubbell, J. H.; Shure, K.; Su, S. ANSI/ANS-6.4. 3-1991; Gamma-Ray Attenuation Coefficients and Buildup Factors for Engineering Materials; American Nuclear Society: La Grange Park, IL, USA, 1991. [Google Scholar]
- Turhan, M. F.; Akman, F.; Taşer, A.; Dilsiz, K.; Oğul, H.; Kaçal, M. R.; Agar, O. Gamma radiation shielding performance of CuxAg(1-x)-alloys: Experimental, theoretical and simulation results. Prog. Nucl. Energy 2022, 143, 104036. [Google Scholar] [CrossRef]
- Yavuzkanat, N.; Şahmaran, T.; Özbey, N. S.; Celik, F. A. Radiation shielding performance of PbO–B2O3–SiO2 glass–ceramics: insights from molecular dynamics, theoretical analyses, and Monte Carlo simulations. J. Mater. Sci. 2026, 2026 61:22(61(22)), 15484–15506. [Google Scholar] [CrossRef]
- Zebardast, V.; Saray, A. A. Experimental and simulation study of shielding features of polyester/HgO composites against photons using GEANT4 and MCNP codes. Sci. Rep. 2025, 2025 15:1(15(1)), 33112. [Google Scholar] [CrossRef] [PubMed]
Figure 1.
Geant4 visualization of the narrow-beam geometry used in this work, with simulated photon tracks shown in green.
Figure 1.
Geant4 visualization of the narrow-beam geometry used in this work, with simulated photon tracks shown in green.

Figure 2.
LAC as a function of photon energy for PGMA, ZnO/PGMA, MoO₃/PGMA, Cs₂O/PGMA, HfO₂/PGMA, and Bi₂O₃/PGMA composites; comparison of Geant4 simulations with Phy-X/PSD calculations: (a) Phy-X/PSD, (b) Geant4.
Figure 2.
LAC as a function of photon energy for PGMA, ZnO/PGMA, MoO₃/PGMA, Cs₂O/PGMA, HfO₂/PGMA, and Bi₂O₃/PGMA composites; comparison of Geant4 simulations with Phy-X/PSD calculations: (a) Phy-X/PSD, (b) Geant4.

Figure 3.
MAC as a function of photon energy for PGMA, ZnO/PGMA, MoO₃/PGMA, Cs₂O/PGMA, HfO₂/PGMA, and Bi₂O₃/PGMA composites; comparison of Geant4 simulations with Phy-X/PSD calculations: (a) Phy-X/PSD, (b) Geant4.
Figure 3.
MAC as a function of photon energy for PGMA, ZnO/PGMA, MoO₃/PGMA, Cs₂O/PGMA, HfO₂/PGMA, and Bi₂O₃/PGMA composites; comparison of Geant4 simulations with Phy-X/PSD calculations: (a) Phy-X/PSD, (b) Geant4.

Figure 4.
Simulated NaI(Tl) pulse-height spectra at 0.662 MeV for the metal oxide/PGMA composites, and the no-absorber reference (I₀); each absorber is at the thickness used in the attenuation scan. Shaded bands: ±1σ statistical uncertainty (below 1.5% at the full-energy peak).
Figure 4.
Simulated NaI(Tl) pulse-height spectra at 0.662 MeV for the metal oxide/PGMA composites, and the no-absorber reference (I₀); each absorber is at the thickness used in the attenuation scan. Shaded bands: ±1σ statistical uncertainty (below 1.5% at the full-energy peak).

Figure 5.
Variation of (a) the MFP and (b) the HVL with photon energy for the metal oxide/PGMA composites, calculated with Phy-X/PSD (curves and solid symbols) and simulated with Geant4 (× symbols).
Figure 5.
Variation of (a) the MFP and (b) the HVL with photon energy for the metal oxide/PGMA composites, calculated with Phy-X/PSD (curves and solid symbols) and simulated with Geant4 (× symbols).

Figure 6.
Variation of (a) Zeff and (b) Neff of the metal oxide/PGMA composites with photon energy.

Figure 7.
Variations of the equivalent atomic number for the metal oxide/PGMA composites with photon energy.
Figure 7.
Variations of the equivalent atomic number for the metal oxide/PGMA composites with photon energy.

Figure 8.
EBF versus photon energy at 1–40 mfp (G-P method, Phy-X/PSD); panels (d) and (f) are truncated at 15 mfp, where the fit diverges.
Figure 8.
EBF versus photon energy at 1–40 mfp (G-P method, Phy-X/PSD); panels (d) and (f) are truncated at 15 mfp, where the fit diverges.

Figure 9.
Fast-neutron removal cross-sections of the PGMA composites calculated with Phy-X/PSD: (a) ΣR; (b) ΣR/ρ. Ordinary concrete is shown for reference.
Figure 9.
Fast-neutron removal cross-sections of the PGMA composites calculated with Phy-X/PSD: (a) ΣR; (b) ΣR/ρ. Ordinary concrete is shown for reference.

Table 1.
Composition, density, and fractions of metal oxide/PGMA materials.
| Composite identifier |
Density (g/cm³) |
Metal oxide content (wt.%) | PGMA content (wt.%) |
| PGMA | 1.07 | 0 | 100 |
| ZnO/PGMA | 1.80 | 50 | 50 |
| MoO3/PGMA | 1.74 | 50 | 50 |
| Cs2O/PGMA | 1.74 | 50 | 50 |
| HfO2/PGMA | 1.93 | 50 | 50 |
| Bi2O3/PGMA | 1.91 | 50 | 50 |
Table 2.
Mass attenuation coefficients (cm²/g) of the composites obtained from Phy-X/PSD and Geant4 at 0.015, 0.020, 0.030, 0.662, 1.173 and 1.332 MeV, with the corresponding relative deviations RD (%).
Table 2.
Mass attenuation coefficients (cm²/g) of the composites obtained from Phy-X/PSD and Geant4 at 0.015, 0.020, 0.030, 0.662, 1.173 and 1.332 MeV, with the corresponding relative deviations RD (%).
| Composite | 0.015 MeV | 0.020 MeV | 0.030 MeV | 0.662 MeV | 1.173 MeV | 1.332 MeV | ||||||||||||
| Phy-X | Geant4 | RD (%) | Phy-X | Geant4 | RD (%) | Phy-X | Geant4 | RD (%) | Phy-X | Geant4 | RD (%) | Phy-X | Geant4 | RD (%) | Phy-X | Geant4 | RD (%) | |
| PGMA | 1.124 | 1.161 | 3.30 | 0.580 | 0.591 | 1.96 | 0.304 | 0.308 | 1.10 | 0.0826 | 0.0829 | 0.37 | 0.0629 | 0.0634 | 0.78 | 0.0589 | 0.0592 | 0.40 |
| ZnO/PGMA | 33.35 | 34.33 | 2.93 | 15.31 | 15.51 | 1.25 | 5.036 | 5.116 | 1.58 | 0.0783 | 0.0785 | 0.26 | 0.0592 | 0.0593 | 0.20 | 0.0555 | 0.0556 | 0.33 |
| MoO3/PGMA | 10.38 | 10.68 | 2.91 | 26.95 | 27.79 | 3.13 | 9.580 | 9.638 | 0.61 | 0.0788 | 0.0792 | 0.43 | 0.0591 | 0.0594 | 0.56 | 0.0553 | 0.0555 | 0.34 |
| Cs2O/PGMA | 29.41 | 30.33 | 3.12 | 13.62 | 13.82 | 1.44 | 4.647 | 4.634 | −0.29 | 0.0803 | 0.0802 | −0.03 | 0.0581 | 0.0581 | −0.08 | 0.0543 | 0.0544 | 0.26 |
| HfO2/PGMA | 55.38 | 57.05 | 3.02 | 26.16 | 26.62 | 1.75 | 9.077 | 9.139 | 0.68 | 0.0875 | 0.0872 | −0.26 | 0.0603 | 0.0604 | 0.23 | 0.0560 | 0.0560 | −0.09 |
| Bi2O3/PGMA | 52.66 | 54.28 | 3.06 | 40.48 | 40.97 | 1.22 | 14.31 | 14.43 | 0.85 | 0.0958 | 0.0958 | 0.00 | 0.0626 | 0.0625 | −0.03 | 0.0578 | 0.0578 | −0.06 |
Table 3.
Comparison of the HVL at 0.662 MeV and the fast-neutron mass removal cross-section ΣR/ρ of the metal oxide/PGMA composites with recently reported polymer composites and reference materials.
Table 3.
Comparison of the HVL at 0.662 MeV and the fast-neutron mass removal cross-section ΣR/ρ of the metal oxide/PGMA composites with recently reported polymer composites and reference materials.
| Material | ρ (g/cm³) | HVL at 0.662 MeV (cm) | ΣR/ρ (cm²/g) | Source |
| PGMA (this work) | 1.07 | 7.84 | 0.0858 | Phy-X/Geant4 |
| ZnO/PGMA (this work) | 1.80 | 4.93 | 0.0542 | Phy-X/Geant4 |
| MoO3/PGMA (this work) | 1.74 | 5.05 | 0.0547 | Phy-X/Geant4 |
| Cs2O/PGMA (this work) | 1.74 | 4.96 | 0.0502 | Phy-X/Geant4 |
| HfO2/PGMA (this work) | 1.93 | 4.11 | 0.0507 | Phy-X/Geant4 |
| Bi2O3/PGMA (this work) | 1.91 | 3.79 | 0.0496 | Phy-X/Geant4 |
| Polyester + 15 wt% WO3 | 1.57 | 5.63 | — | Experimental (Isazadeh & Saray, 2025) |
| Polyester + 15 wt% HgO | 1.59 | 5.17 | — | Experimental (Zebardast & Saray, 2025) |
| Ordinary concrete (NIST) | 2.30 | 3.87 | 0.0407 | Calculated (this work) |
| Lead | 11.35 | 0.55 | 0.0104 | Calculated (this work) |
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.
Copyright: This open access article is published under a Creative Commons CC BY 4.0 license, which permit the free download, distribution, and reuse, provided that the author and preprint are cited in any reuse.