Preprint
Article

This version is not peer-reviewed.

A Fringe-Shift Measurement of the Photon Circulation Radius: A Test of the Helical Identity mcrγ = ħ

Submitted:

02 November 2026

Posted:

04 November 2026

Read the latest preprint version here

Abstract
We propose a test of the postulate that a photon carrying kinetic mass m = E/c2 circulates about its propagation axis, implying mcrγ = ħ. Because this identity follows from E = mc2 and E = hν, it is empirical only if rγ is measured independently of λ. We show that circulation coupling to slit edges imprints a helicity-odd phase ramp that rigidly shifts the far field by Δx/X = Crγ/a. The shift scales as λ and 1/a, preserves all fringe spacings, and vanishes for linear polarization. Phase metrology at 10−3–10−4 rad tests order-unity C at a fractional precision of 0.27–2.7% on rγ per frame-equivalent, reaching 0.04–0.39% after 50-frame averaging; failure of the helicity, scaling, or classical/quantum criterion falsifies the postulate.
Keywords: 
;  ;  ;  ;  ;  

1. Introduction

We propose a decisive test of whether a photon carries internal transverse kinematics. Detection is pointlike [1,2,3], yet standard optics assigns the quantum no trajectory between emission and absorption, and even its position operator is nonstandard [4].
The spiral structure model (SSM) gives a definite answer [5,6,7]: a photon carries kinetic mass m = E/c2, advances at c along an axis, and circulates at c about that axis. At the kinematic level the picture reproduces the photon energy, momentum, angular momentum, and polarization structure [6]. What it has lacked is a measurement that can decide it.
The obstacle is circularity. The central identity mcrγ = ħ follows from E = mc2 and E = hν and is guaranteed if the circulation radius is inferred from rγ = λ/2π. We therefore seek an observable that measures rγ without passing through λ. We show that circulation coupling to the two edges of a slit predicts a helicity-odd, rigid translation of the far-field pattern by Δx/X = Crγ/a. The translation preserves all fringe spacings, scales as λ and 1/a, and vanishes for linear polarization. If confirmed, the experiment converts a kinematic identity that normally serves as a consistency relation into a direct measurement of the photon's internal transverse structure, a test of whether the photon carries measurable circulation, orthogonal to spin expectation values. Statements are labeled [P] postulate, [T] theorem within the postulate, [M] model estimate, and [F] falsifiable prediction.

2. Helical Hypothesis

Postulate [P]. A photon of energy E is a pointlike quantum of zero rest mass carrying kinetic mass m = E/c2 [6,8]. Its motion is uniform translation at speed c along an axis together with uniform circulation at speed c about that axis,
r ( t ) = ( r γ cos ω t , r γ sin   ω t ,   ct )
where rγ and ω are the circulation radius and angular frequency. The composite speed √2 c belongs to the kinematic image, not to propagation: the axial advance is c, no energy or signal is transported at √2 c, and the relativistic mass–velocity relation does not apply to a quantum of zero rest mass. The helix is therefore not proposed as a Minkowski worldline.
The axial momentum pz = mc carries the energy transport, while the transverse momentum p⊥ = mc carries the circulation angular momentum and adds no energy [6]; the kinetic mass variable is familiar from Compton kinematics [9],
p total = ( p z 2 + p ⊥ 2 ) 1 / 2 = 2 mc ,     E = p z c = mc 2 .
The circulation completes one turn while the axis advances by one wavelength, so ν = c/(2πrγ). The relations E = mc2 [8] and E = hν then give
mc 2 = hc 2 π r γ ⇒     mc r γ = ħ , r γ = ħ mc = λ 2 π .
The circulation angular momentum is L = mcrγ = ħ, which the framework identifies with photon spin [5]; matter absorbs angular momentum ħ together with energy ħω per photon [10]. The two senses of circulation are identified with the two photon helicities [5]: switching from σ+ to σ− reverses the circulation. Linear polarization is an equal superposition of the two helicities, so any circulation-odd observable cancels in that ensemble (Appendix A.6).
Equation (3) is a consistency theorem, not an empirical result [T]: the identity follows from E = mc2 and E = hν only once the helical motion of Equation (1) is postulated — a quantum of zero rest mass but nonzero kinetic mass m = E/c2 completing one circulation turn per wavelength of axial advance — and it is empty without that motion. It becomes testable only when rγ is measured independently of λ. Within the model the product mcrγ is invariant under longitudinal boosts [6]. The postulate is trajectory-like in the spirit of de Broglie–Bohm mechanics [11], but the present test uses only the circulation kinematics and boundary coupling; it does not rely on the Bohmian guidance law or a hidden-variable interpretation.

3. Slit-Edge Fringe Shift

Rotational-angle coupling [P]. In the helical picture the photon carries a real internal phase φ = ωt [5]. A slit of finite width samples the transverse phase structure, and its two edges are mirror-image boundaries with respect to the circulation; reversing the circulation interchanges their roles. The coupling is geometric and non-dissipative: it exchanges no energy with the mask [5]. Momentum bookkeeping follows ordinary diffraction. The aperture phase ramp tilts the transmitted wavefront, so each transmitted photon carries the mean transverse momentum ⟨px⟩ = ħκ = ±C(2πħrγ/a2), a deflection of κ/k = Crγλ/a2 ≈ 16 mrad at the reference configuration of Table 4, and the mask takes up the balancing recoil, whose direction follows the circulation sense.
Edge phase [M]. The phase–boundary coupling was introduced for slit pairs in [5], with the geometric scale δφ ∼ 2πrγ/a. Applied to the two edges of one slit of width a, mirror symmetry gives equal and opposite edge imprints and hence the differential phase
δ φ = C · 2 π r γ a ,
whose sign follows the circulation sense. The edge pair therefore impresses a linear aperture phase φ(x) = ±C(2πrγ/a2)x. Two elements of this step should be distinguished. The per-edge imprints (equal in magnitude, opposite in sign, helicity-odd, and entering as a phase rather than an amplitude) are fixed by mirror symmetry (Appendix A.5). The interpolation of the two edge imprints into a linear profile across the aperture interior is the minimal constant-gradient completion and constitutes the central dynamical ansatz of the model: edge-localized alternatives satisfying the same symmetries predict only an O((rγ/a)2) reshaping of the pattern, without a rigid translation, and are discriminated from Equation (4) by the scaling tests of Sec. 7 (Appendix A.7). Scalar diffraction contains no such circulation term: its boundary waves carry phases fixed by geometric path lengths [12]. The order-unity prefactor C is the single free parameter; the Φ–w coupling that would derive it remains open in the dynamical program [7], and the experiment measures the combination C(2πrγ/λ).
Fringe shift [F]. A linear phase across an aperture translates its far-field pattern rigidly by the Fourier shift theorem: all spacings remain unchanged and only the absolute position moves. The shift is a fraction
Δ x X = δ φ 2 π = ± C · r γ a = ± C · λ 2 π a
of the characteristic pattern scale X (X = λf/a for a single slit and X = λf/d for a double slit), with the sign fixed by helicity. The only free parameter is C: the measurement determines the combination C(2πrγ/λ), not a value of rγ inferred from λ. In absolute units the measurement is purely geometric: the shift ratio and the slit width give Crγ = a·Δx/X with no spectroscopic input, and the comparison of this optically measured length with λ/2π is the content of criterion K6. Unlike a path-difference phase, it grows as λ at fixed geometry and falls as 1/a at fixed wavelength. At λ = 633 nm, a = 2 μm, and C = 1, the displacement is 5.0% of the pattern scale, approximately 4.0 mm at f = 0.25 m (Fig. 1).
The prediction survives averaging over the initial rotational angle [T, conditional]. The initial angle is uniformly distributed, g(φ) = 1/2π, while the edge imprint is referenced to the fixed edge orientation [5]. A circularly polarized ensemble has one circulation sense and shows the full shift. Linearly polarized or unpolarized light superposes I0(x − Δx) and I0(x + Δx), whose centroid vanishes identically. Linear polarization is thus the built-in null, not the working point.

4. Discriminating Power and Signal Budget

The signature is discriminating because of its joint structure: helicity-odd, linear in λ, inverse in a, and a rigid translation with unchanged fringe spacings. Table 1 compares the standard candidates. No candidate satisfies all four conditions.
The closest mimics are edge spin–orbit coupling, Pancharatnam–Berry (PB) phases, and orbital-angular-momentum beams; the last can displace double-slit fringes [15], but only through a nonzero incident ℓ spectrum. Surface-plasmon spin–momentum locking is helicity-dependent, but its phases scale as 1/λ, remain localized near the rim, and depend strongly on material; chromium, gold, and dielectric-membrane variants bound this contribution. PB elements do produce helicity-odd rigid shifts, but they require a spatially varying anisotropy that an isotropic slit does not possess, and they are achromatic [13,14]. A calibrated PB element therefore serves as a positive control, not as a mimic.
Table 2 gives the signal budget. At C = 1 the predicted translations span 0.64–10.1% of the pattern scale. The three wavelengths fix the radius ratio 1: 1.314 : 1.563; each wavelength supplies an independent 1/a scan.
Figure 1. (a) Standard and helicity-resolved far-field patterns at λ = 633 nm and a = 2 μm. The translation is helicity-odd, preserves all fringe spacings, and vanishes for linear polarization; the inset resolves the first minimum on a logarithmic scale. (b) Predicted |Δx|/X versus λ for a = 1, 2, 5, and 10 μm, compared with the ordinary 1/λ phase scaling.
Figure 1. (a) Standard and helicity-resolved far-field patterns at λ = 633 nm and a = 2 μm. The translation is helicity-odd, preserves all fringe spacings, and vanishes for linear polarization; the inset resolves the first minimum on a logarithmic scale. (b) Predicted |Δx|/X versus λ for a = 1, 2, 5, and 10 μm, compared with the ordinary 1/λ phase scaling.
Preprints 242027 g001

5. Protocol and Error Budget

Measure the absolute far-field position against fiducials ruled on the mask, switching rapidly between σ+ and σ− illumination. The primary observable is the helicity difference: helicity-independent offsets, drift, tilt, and static edge asymmetry cancel, while the helicity-averaged channel is a continuous null monitor. Scan λ = 405, 532, and 633 nm and a = 1, 2, 5, and 10 μm at otherwise fixed geometry. Stabilized lasers provide the ensemble measurement; heralded parametric down-conversion repeats the measurement photon by photon [18,19]. All components are existing technologies; the twelve-configuration scan requires no new device development.
Table 3. Protocol and systematics budget. One frame-equivalent means N = 106 detected photons; at a heralded rate of 105 s−1 it requires about 10 s.
Table 3. Protocol and systematics budget. One frame-equivalent means N = 106 detected photons; at a heralded rate of 105 s−1 it requires about 10 s.
Element Specification Role/Suppression
Sources Stabilized 405/532/633 nm CW lasers with photoelastic helicity switching; heralded SPDC, g2(0) < 0.5 [18,19] Helicity-resolved ensemble and single-photon comparison
Masks E-beam slits, a = 1, 2, 5, 10 μm; Cr/SiO2, SiN membrane, and Au variants 1/a scan and material-systematics bound
Readout Heterodyne position readout referenced to mask fiducials, 10−3–10−4 rad [16,17] Absolute translation rather than fringe spacing
Detectors EMCCD/SPAD array or superconducting nanowire detectors [18] Photon-counting verification
Positive control Calibrated PB element with known helicity-odd shift [13,14] End-to-end metrology and sign validation
Null controls Linear polarization; defocused/aberrated reference; roughened and material-variant masks Internal veto and classical-edge bound
Photon statistics N = 106 detected photons per frame-equivalent; 50-frame averaging 21.8 μm → 3.1 μm at the reference point
Smooth gain/roughness 2% rms injected distortion; median 1.9% (worst 7.1% of 40 realizations) single-channel spurious shift Static: cancels in the helicity difference; joint λ, 1/a fit suppresses the remainder
Static edge asymmetry Lithographic or penetration-depth differences between edges Cancels differentially; nonzero linear-pol result vetoes the run
Instrument drift Mask–camera and fiducial drift Fast helicity switching and common fiducials
Readout noise 3 counts rms per 4 μm pixel Included in weighted estimator
For N detected photons in one frame-equivalent, the Fisher information for a rigid translation of the single-slit pattern gives (Appendix B)
σ ( Δ x ) = λ f 2 π a · 3 N .
The focal length cancels from the fractional precision, σ(rγ)/rγ = (√3/2π)(a/rγ)N−1/2. The helicity-differential readout keeps this precision at fixed total photon number: the two channels' noises add in quadrature against a doubled signal (Appendix B). Table 4 lists the resulting budget at f = 0.25 m. The end-to-end simulation includes the aperture phase, propagation, Poisson noise, 3-count readout noise, and 2% rms smooth gain or edge-roughness distortion. Its truncated matched-filter estimator reaches 1.4× the on-support Fisher bound; 800 null realizations give sub-μm bias and scatter statistically consistent with the signal run, the largest deviation being 3.1σ (Appendices C–E).
Table 4. Photon-counting error budget at λ = 633 nm, f = 0.25 m, N = 106, and C = 1. The final column averages 50 frame-equivalents.
Table 4. Photon-counting error budget at λ = 633 nm, f = 0.25 m, N = 106, and C = 1. The final column averages 50 frame-equivalents.
a (μm) Shift Δx (mm) σ(Δx) per Frame-Equivalent (μm) σ(rγ)/rγ per Frame 50-Frame Average
1 15.9 43.6 0.27% 0.04%
2 3.99 21.8 0.55% 0.08%
5 0.64 8.7 1.4% 0.19%
10 0.16 4.4 2.7% 0.39%

6. Compatibility with Existing Data

The predicted effect is not excluded by the existing record because the required observable has not been measured. Diffraction experiments ordinarily extract spacings and widths, both invariant under rigid translation. They do not normally record the absolute pattern centroid relative to mask fiducials, resolved by helicity, across independent λ and 1/a scans. Linear-polarization data are also uninformative because the predicted centroid is exactly zero.
Two structural features explain why an order-unity coupling could escape detection despite the macroscopic size of the reference shift (4.0 mm at f = 0.25 m). First, the observables of routine optical practice (spatial-filter throughput, fiber-coupling efficiency, mode matching) are even in the spot displacement: the mode-overlap integral is quadratic in Δx/X, so a translation of 5% of the pattern scale degrades coupling only at the 10−3 level, within ordinary alignment and drift tolerances. The first-order observable is the absolute, mask-referenced, helicity-resolved centroid, which routine practice does not record. Second, precision beam-deflection metrology, including photonic spin-Hall and weak-value measurements with sub-nanometer sensitivity, probes interface-induced, near-field spin–orbit shifts at material boundaries, an observable class distinct from the free-space far-field translation of a slit pattern proposed here. The proposed measurement therefore occupies an untested region rather than contradicting established diffraction results.

7. Kill Criteria and Outlook

K1 (Null). A null result — no helicity-odd, mask-referenced translation at the stated sensitivity — bounds C ≪ 1 and excludes order-unity coupling.
K2 (Sign). A translation that does not reverse between σ+ and σ− is not circulation-coupled.
K3 (λ scaling). A shift that does not grow linearly with λ at fixed geometry is not the helical term.
K4 (a scaling). A shift that does not scale as 1/a at fixed wavelength is not the proposed edge coupling.
K5 (Classical/quantum). Disagreement between classical-light and heralded-single-photon measurements falsifies the stated single-photon mechanism.
K6 (Magnitude). If both scalings hold but the measured C(2πrγ/λ) differs from unity, the conjunction of the geometric locking rγ = λ/2π and the order-unity coupling C = 1 is falsified; the observable fixes the product, and the model predicts the two factors jointly.
K7 (Classical edge electrodynamics). If material variants or full-vector FDTD reproduce the joint signature, the signal is classical edge physics rather than circulation.
A confirmed joint signature would measure the circulation radius without inferring it from λ and would turn the helical identity from a consistency relation into an empirical result. A null or inconsistent result would close the model in its stated order-unity form.

CRediT Authorship Contribution Statement

Jinjun Cheng: Conceptualization, Methodology, Formal analysis, Writing – original draft. Dian Cheng: Validation, Investigation, Writing – review & editing.

Declaration of Competing Interest

The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Data Availability

No new experimental data were generated. The Python source SSM_fringe_shift_simulation_v8.py reproduces Fig. 1, Table 2 and Table 4, the Fisher analysis, the Monte Carlo validation, the smooth-distortion ensemble, and the linear-polarization null; it is reproduced in full as Listing E1 in Appendix E and provided as a separate file. All simulation values reported in the text and tables are the verbatim output of this script with its fixed random seeds.

Funding

This research did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors.

Acknowledgments

The authors thank the developers of the open numerical tools used for the verification calculations.

Appendix A. Standard Diffraction Produces No Rigid Translation; Symmetry and Helicity Structure

A.1. The Shift Condition in the Fourier Plane

In Helmholtz–Kirchhoff (or Rayleigh–Sommerfeld) scalar diffraction the far field is the Fourier transform of the aperture transmission t(x): a rigid translation Δxf of the whole pattern occurs if and only if t(x) acquires a phase factor exp(iκx) linear in the aperture coordinate, with κ = 2πΔxf/(λf) (the shift theorem). For a single slit, t(x) = rect(x/a) and the amplitude U(kx) ∝ a sinc(kxa/2), with kx = 2πxf/(λf), has its minima at xf = mλf/a; because t(x) is even, the origin never moves and changing a only rescales the pattern about a fixed center. For a double slit of separation d ≫ a, I(kx) ∝ sinc2(kxa/2) cos2(kxd/2): the comb positions xf = nλf/d are independent of a at leading order, and the slit width modulates only the sinc2 envelope.

A.2. Boundary-Diffraction-Wave Analysis

In the Maggi–Rubinowicz formulation [12,13,14,15,16,17,18,19,20,21] the diffracted field splits into a geometrical-optics term and an edge wave, a line integral along the aperture rim whose phase at each edge point is set by the geometric path length kR. For two symmetric edges the edge wave reduces to exp(ikL) × [exp(ikxa/2)F+ + exp(−ikxa/2)F−] ∝ exp(ikL) cos(kxa/2) × (a slowly varying envelope): a symmetric modulation with no component linear in x across the aperture interior. A real absorptive edge modifies amplitudes; the boundary wave carries phases set by geometric path lengths, scaling as 1/λ at fixed geometry, not a circulation-coupled phase linear in x.
The exclusion extends from the scalar kernel to full vector diffraction by symmetry and by mechanism. For illumination that is invariant under the slit mirror (any linear polarization, parallel or perpendicular to the edges, at normal incidence), the boundary-value problem is invariant under x → −x and the exact vector intensity is even. For helicity-resolved illumination the mirror maps σ+ ↔ σ−, so Iσ+(x) = Iσ−(−x). Two comments are in order. First, this mirror relation is exactly what a helicity-odd rigid translation satisfies, since I0(x ∓ Δx) obeys it for even I0: mirror symmetry therefore constrains the transformation law of any translation but does not by itself exclude one. Second, what excludes the effect in standard electromagnetism is the absence of a mechanism: a passive, achiral, isotropic absorptive mask possesses no anisotropy axis and no optical activity, and reciprocity forbids a helicity-dependent phase gradient across its aperture. Helicity-dependent edge phases enter only through near-field spin–orbit coupling localized within a wavelength of the rim (with phases that scale as 1/λ, a strength that depends on the material, and a reshaping rather than a translation of the pattern) or through symmetry-breaking edge asymmetries, which are static and cancel in the helicity-differential readout (Appendix D). The material-variant control and the FDTD control computations of Section 4 and Section 5 of the main text bound both channels.

A.3. Angular-Spectrum Formulation

The aperture field decomposes into plane waves with spectrum A(kx) = (1/2π) ∫ t(x) exp(−ikxx) dx. A slit gives a sinc spectrum centered at kx = 0; translating the pattern means re-centering the spectrum at kx = K0, which requires t(x) → t(x) exp(iK0x). No passive absorptive structure supplies such a factor; only active or periodically structured elements (spatial light modulators, gratings, gradient-index components) do so, by construction, and the masks considered here are none of these.

A.4. Contrast with the Helical Term

The circulation phase of Section 3 of the main text is just such a ramp:
t helical ( x )   =   t ( x )   exp ( ± iC 2 π r γ a 2 x ) ,
of slope ±C·2πrγ/a2 and total differential phase ±C·2πrγ/a between the edges, the sign following the illumination helicity. Consequently, any observed pattern translation that (i) reverses sign between σ+ and σ− illumination, (ii) grows linearly with λ at fixed geometry, (iii) scales as 1/a at fixed λ, and (iv) leaves all spacings invariant cannot be accounted for by standard scalar diffraction and isolates the circulation-phase contribution of Equation (4).

A.5. Geometric Structure of the Edge Prefactor

Three properties of Equation (4) are fixed by symmetry rather than by the unfinished edge dynamics (Ref. [7] of the main text). First, the two edges of the slit are mirror images with respect to the circulation sense; their phase imprints on the transmitted circulation are therefore equal in magnitude and opposite in sign, and the observable differential phase is twice the per-edge imprint. The factor of two in Equation (4) is a symmetry statement, not a fit. Second, reversing the circulation sense interchanges the roles of the two edges, so the differential phase is odd under helicity reversal, δφ(σ+) = −δφ(σ−). This is what ties the sign of the translation to a measured property of the illumination rather than to a convention. Third, the imprint is a phase, not an amplitude modulation: by the shift theorem, only a phase factor linear in the aperture coordinate produces a rigid translation with invariant spacings; a purely real, absorptive edge modulation reshapes the pattern and cannot translate it. The directional character of the coupling of Section 3 therefore enters the transmitted field as a phase referenced to the fixed orientation of each edge, the phase–boundary coupling of Ref. [5] of the main text, restricted here to the two edges of a single slit. Since the imprint is referenced to the edge orientation and not to the arrival angle φ, the uniform ensemble g(φ) = 1/2π retains the full differential phase. The per-edge imprint must vanish with rγ/a and must be odd under interchange of the edges; the leading geometric term is the ratio rγ/a times the phase scale 2π of one circulation turn. What remains genuinely open is the order-unity constant C multiplying this geometric scale, which the completed edge dynamics must supply and which the experiment measures in the combination C(2πrγ/λ); the test and the kill criteria of Section 7 of the main text rest on the scaling laws, the helicity structure, and the dimensionless value, not on C. We stress that symmetry constrains only the imprint structure at the two edges; the spatial profile of the phase across the aperture interior is an ansatz, analyzed in Sec. A.7, not a symmetry theorem.

A.6. Helicity Resolution of the Ensemble Prediction

Let I0(x) denote the standard far-field intensity and Δx = C(rγ/a)x1 the single-helicity shift, with x1 = λf/a. A σ+ ensemble carries one circulation sense and yields I+(x) = I0(x − Δx); a σ− ensemble yields I−(x) = I0(x + Δx). Linearly polarized light is the equal superposition (σ+ + σ−)/√2; the two helicity components are orthogonally polarized and do not interfere, so the recorded intensity is
I lin ( x ) = 1 2 I 0 ( x − Δ x ) + 1 2 I 0 ( x + Δ x ) ,
which is even: its centroid vanishes identically, and no matched-filter translation estimator can extract a systematic shift from it. (The superposition is slightly broadened relative to I0, but the broadening enters only at order (Δx/x1)2 and is not a competitive readout.) The same holds a fortiori for unpolarized light. The measurement therefore works with circular polarization, and linear polarization provides the internal null: any nonzero translation measured with linearly polarized illumination is instrumental and vetoes the run (Section 5 of the main text). Numerically, at λ = 633 nm, a = 2 μm, C = 1, the linear-polarization centroid vanishes to machine precision while the single-helicity shift is 3.99 mm (Appendix E).

A.7. Aperture Phase Profile: Ramp Ansatz Versus Edge-Localized Alternatives

Write the transmitted field behind the slit as t(x) = rect(x/a) exp[iφ(x)], with the edge values φ(±a/2) = ±δφ/2 fixed by the imprints of Sec. A.5. Symmetry does not determine φ(x) in the interior; two completions illustrate what the experiment actually tests.
(i) Constant-gradient (ramp) completion, φ(x) = (δφ/a)x, the unique linear profile through the edge values. By the shift theorem it translates the far field rigidly by Δx/X = δφ/2π = Crγ/a: first order in rγ/a, linear in λ, inverse in a. This is the ansatz of Equation (4).
(ii) Boundary-layer completion, with the imprints confined to layers of width w ∼ rγ at the two edges. The overlap of such a profile with a uniform ramp carries the filling factor ∼ w/a, so the effective translation is of order Δx/X ∼ C(rγ/a)·(w/a) ≈ C(rγ/a)2 ≈ 2.5 × 10−3 at the reference configuration, appearing as a weak reshaping of the pattern rather than a clean translation. Its wavelength and slit-width scalings, (rγ/a)2 ∝ λ2/a2, differ from Equation (5) on both counts.
The completions are therefore discriminated by the experiment itself: kill criteria K3 and K4 (linear-in-λ and 1/a scaling) select the ramp form, while K1 bounds any completion whose translation falls below the order-unity prediction. The ansatz tested here is the strongest, and the minimal, member of the symmetry-allowed family; should the experiment return a null, the boundary-layer class remains as a weaker, already nearly excluded fallback, with an expected signal below the stated sensitivity by a factor ∼ rγ/a.

Appendix B. Derivation of the Photon-Counting Fisher Bound (Equation (6))

The far-field single-slit intensity for a slit of width a, wavelength λ and effective focal length f is, in the normalized coordinate u = π(x − Δx)/x1 with x1 = λf/a,
p ( x ;   Δ x ) = 1 x 1 sinc 2 ( u ) ,     sinc ( u ) = sin ( u ) / u , ∫ sinc 2 ( u )   du = π ,
so p is a normalized probability density for the arrival position of a single photon, and Δx is the (possibly zero) rigid translation to be estimated. For N independent detected photons the total Fisher information is Ftotal = NFsingle, with per-photon information Fsingle = ∫ (p′)2/p dx, since ∂p/∂Δx = −∂p/∂x. The integrand (g′)2/g with g(u) = sinc2(u) looks singular at the zeros of the pattern, but writing g = h2 with h(u) = sinc(u) gives the exact identity (g′)2/g = 4(h′)2, regular everywhere: the zeros of a sinc2 pattern carry no information divergence. Changing variables to u and using ∫ (sinc′(u))2 du = π/3 (a Parseval evaluation: sinc is the Fourier transform of the unit rectangle, so the squared-derivative integral equals the second moment of the rectangle), one obtains
F single = 4 π 2 3 x 1 2 = 4 π 2 a 2 3 ( λ f ) 2 ,
and the Cramér–Rao bound per frame of N photons is
σ ( Δ x ) = 1 / N F single = x 1 2 π 3 N ,
which is Equation (6). Two consequences follow. First, the fractional precision on the circulation radius, σ(rγ)/rγ = (√3/2π)(a/rγ)N−1/2, is independent of the focal length: increasing f magnifies the shift and the noise by the same factor. Second, the signal-to-noise ratio per frame is SNR = Δx/σ(Δx) = 2π(rγ/a)√(N/3); at a = 2 μm and λ = 633 nm (rγ/a ≈ 0.050) with N = 106, the single-frame SNR is ≈ 183, and fifty frames give a fractional precision near 0.08% on rγ.
Helicity-differential readout. The experiment estimates the difference of two frames of N photons each, taken at opposite helicities. The differential signal is 2Δx and the two channels' independent photon noise adds in quadrature, so σ(2Δx) = √2·σ(Δx) per frame pair, and at fixed total photon number 2N the fractional precision on rγ is unchanged. All statements of Equation (6) and Table 4 therefore apply to the single-helicity shift at the quoted per-frame photon number.
A finite detection window weakens the bound slightly. The estimator of Appendix C works on a window of ±1.5 x1 about the pattern center; restricting the Fisher integral to this support and normalizing p on the window gives σ(Δx) = 23.7 μm at the reference configuration (λ = 633 nm, f = 0.25 m, a = 2 μm, N = 106), against 21.8 μm for the full pattern. The windowed value, evaluated by direct numerical quadrature of the same integral, is the relevant benchmark for the simulation of Appendix C. (The full-pattern values of Table 4 come from Equation (6); the windowed benchmark applies only to the Monte Carlo comparison of Appendix C, and the two should not be mixed.)

Appendix C. Translation Estimator and Monte Carlo Validation

The translation is estimated by an iterative matched filter (Fisher scoring). Starting from Δx̂ = 0, each iteration evaluates the weighted score with Poisson weights w = 1/max(μ, μ0), where μ(x; Δx̂) is the current model prediction and the truncation floor μ0 = 10 counts keeps the near-zero pixels in the pattern minima from acquiring divergent leverage (an untruncated 1/μ weighting amplifies single-count fluctuations by two orders of magnitude and destabilizes the iteration). The update step is clipped at ±0.3 x1 per iteration, which makes the estimator insensitive to initialization while converging in fewer than ten iterations. Simulated frames contain N = 106 photons with Poisson arrival noise plus a Gaussian readout of 3 counts rms per 4 μm pixel; the model family is the exact sinc2 pattern with the aperture phase ramp of Equation (4). The estimator is applied per helicity channel; the experimental observable is the difference of the two channels (Appendix B).
Table C1. End-to-end Monte Carlo validation at λ = 633 nm, f = 0.25 m, a = 2 μm, N = 106 photons per frame-equivalent (C = 1). All values are the verbatim output of SSM_fringe_shift_simulation_v8.py with its fixed random seeds. "Full-pattern bound" is Equation (6); "on-support bound" is the Fisher bound restricted to the simulated window ±1.5 x1 (Appendix B).
Table C1. End-to-end Monte Carlo validation at λ = 633 nm, f = 0.25 m, a = 2 μm, N = 106 photons per frame-equivalent (C = 1). All values are the verbatim output of SSM_fringe_shift_simulation_v8.py with its fixed random seeds. "Full-pattern bound" is Equation (6); "on-support bound" is the Fisher bound restricted to the simulated window ±1.5 x1 (Appendix B).
Quantity Full-Pattern Bound On-Support Bound Monte Carlo (Signal) Monte Carlo (Null, rγ = 0)
σ(Δx) per frame 21.8 μm 23.7 μm 32.3 μm (1.4 × on-support bound) 35.0 μm (statistically consistent; see text)
Estimator bias — — +3.5 μm (0.09% of shift; 1.3 standard errors of the mean) +0.3 μm (consistent with zero)
Largest |estimate| — — — 3.11σ; 0 of 800 beyond 5σ (Gaussian expectation 5 × 10−4)
The realized scatter is 1.4 times the on-support Fisher bound, the price of the truncated weights and step clipping, which cost a factor 1.36 (< √2) in standard deviation, i.e. 1.9 in variance, in exchange for numerical robustness. The null scatter (35.0 μm) exceeds the signal scatter (32.3 μm) by 8%; with the sampling errors of the scatter estimates (5.8% at n = 150 and 2.5% at n = 800) the two are statistically consistent (1.3σ), the sign of the difference itself lying within sampling variation, and nothing in the estimator distinguishes the two modes. The null test is the operative one for a falsification experiment, and its interpretation should be stated precisely: with 800 realizations the Gaussian expectation beyond 5σ is 5 × 10−4 events, so the run probes the tails only to about 3σ (one event observed beyond 3σ against 2.2 expected). The supported conclusion is that the estimator introduces no spurious translation and that its scatter is consistent with Gaussianity over the range probed, not that the 5σ tail itself has been measured. As a direct check of the differential readout, a paired Monte Carlo of 150 frame pairs (one σ+ and one σ− frame per pair, 106 photons each) gives a per-pair scatter on Δx of 24.5 μm, matching the √2/2 reduction of the single-channel scatter expected when the two channel noises add in quadrature against a doubled signal, so the fractional precision of Table 4 is unchanged at fixed total photon number. The signal-mode bias is seed-dependent but bounded: repeating the 150-realization signal run at five independent seeds gives biases from +1.4 to +7.5 μm, and a single 800-realization run gives +1.8 μm (1.5 standard errors of the mean), so the residual bias never exceeds 0.2σ(Δx) and adds at most 2% in quadrature to the error budget.

Appendix D. Smooth-Distortion Systematics and Their Suppression

The dominant instrumental systematic is a smooth, multiplicative distortion of the pattern (pixel-to-pixel gain variation, vignetting, or edge roughness of the mask), which an unguarded matched filter can read as a translation. Injecting a random smooth gain field of 2% rms (correlation length one fringe spacing, 31 knots across the window) into the simulated frames and repeating over an ensemble of 40 independent distortion realizations (20 estimator repetitions each, so that photon noise contributes less than 0.2% of the shift to each per-realization value) yields per-realization spurious translations of median 1.9% and mean 2.4% of the predicted shift, reaching 7.1% in the worst realization; the sign varies randomly from realization to realization (26 positive, 14 negative; ensemble mean +0.3% ± 0.4% SEM, consistent with zero). These figures characterize a single helicity channel. Three properties of the protocol suppress this class below the photon noise in the reported observable. (i) All such distortions are static and helicity-independent: they cancel in the helicity-differential readout Δx(σ+) − Δx(σ−), which is formed from frames recorded on the same mask within one drift period of each other, so that the two channels share the same realization of any static distortion. (ii) The analysis never fits a single pattern in isolation but performs a joint fit of the scaling laws Δx ∝ λ at fixed a and Δx ∝ 1/a at fixed λ across the twelve configurations, in which a zero-mean random-sign per-mask contribution of rms ≈ 2.4% of the shift averages down in ensemble expectation to ≈ 0.7%. (iii) The roughened-mask control of Section 5, a deliberately abraded replica of each mask, bounds the residual distortion directly.
A further class deserves explicit mention: spatially correlated edge asymmetries, meaning systematic differences between the profiles of the two edges of a slit, whether from lithography or from wavelength-dependent penetration into the absorber. Such asymmetry breaks the mirror protection established in Appendix A.2 and can imprint a static phase gradient that mimics a ramp. It is nonetheless helicity-independent: the edge geometry does not change when the illumination helicity flips, so the spurious translation is the same in both channels and cancels in the differential readout. What remains is the class of helicity-correlated distortion (polarization-dependent transmission asymmetry of the mask), and this is bounded twice over: by the linear-polarization null of Section 5 of the main text, where any static asymmetry shows up as a nonzero translation and vetoes the run, and by the material variants, since a polarization-dependent edge effect is strongly material-dependent while the prediction is material-independent.

Appendix E. Reproduction Script

The script SSM_fringe_shift_simulation_v8.py (Python 3.10+; NumPy for the numerical pipeline, matplotlib only for the optional fig1() function; reproduced in full as Listing E1 below for archival completeness) reproduces every numerical element of the paper: (1) Fig. 1, via fig1(), which evaluates the exact aperture pattern with and without the circulation-phase ramp κ = ±C·2πrγ/a2 for the two helicity channels; (2) Table 2 and Table 4, from rγ = λ/2π and Equation (6); (3) the Monte Carlo validation of Appendix C, via mc_screen(a_um, N, nrep, mode) with mode = 'signal' and mode = 'null'; (4) the smooth-distortion ensemble of Appendix D, via rough_ensemble(), which reports per-realization spurious-shift statistics over 40 independent 31-knot gain-field realizations; (5) the linear-polarization null of Appendix A.6, via linpol_null_demo(). All random seeds are fixed; running the script end-to-end takes a few minutes on a desktop machine. All quantities are SI; r_gamma() returns metres. Every simulation value quoted in the text and in Table C1 is the verbatim output of this script.
# Supplementary simulation script for "A fringe-shift measurement of the photon circulation
# radius: a test of the helical identity mcr_gamma = hbar" (J. Cheng & D. Cheng), version 8.
# Contents: (1) Fig. 1 pattern engine (helicity-resolved) plus an optional fig1()
# reproduction of Fig. 1; (2) Fisher error budget (Table 2 and Table 4 of the main text);
# (3) Monte Carlo end-to-end validation (Appendix C) and the smooth-distortion
# ENSEMBLE (Appendix D, statistics over 40 independent distortion realizations);
# (4) linear-polarization null demonstration ( Appendix A.6 ).
# Python 3.10+; numpy for the numerical pipeline, matplotlib only for the optional
# fig1(). All random seeds are fixed.
#
# v6 -> v7 changes:
# * added rough_ensemble(): spurious-shift statistics over 40 independent smooth-gain
# realizations (the v6 single-realization run could not support the "per mask, random
# sign" claim; the ensemble gives median 1.9%, mean 2.4%, worst 7.1% of the shift).
# * __main__ reports the Monte Carlo summary exactly as quoted in Appendix Table C1
# (signal: sigma = 32.3 um, bias = +3.5 um; null: sigma = 35.0 um, bias = +0.3 um,
# largest deviation 3.11 sigma, 0/800 beyond 5 sigma).
# v7 -> v8 changes:
# * renamed for the Optics Communications submission package; appendix-style
# cross-references (Appendix A-E) replace the PRL-style section references.
# Numerical content, seeds, and outputs are identical to v7, plus one added
# check: paired_differential_demo() (Appendix C, helicity-difference precision).
# v8 review changes (numerics unchanged):
# * fig1() added: regenerates Fig. 1 directly (matplotlib, optional; the numerical
# pipeline itself remains numpy-only).
# * seed robustness of the signal-mode estimator bias documented in Appendix C:
# five independent seeds (nrep = 150) give biases +1.4 to +7.5 um and an
# nrep = 800 run gives +1.8 um (1.5 SEM); residual bias <= 0.2 sigma worst case.
import numpy as np
import numpy.fft as fft
.
# ---------------- physical constants and configuration ----------------
lam = 633e-9 # wavelength (m)
f = 0.25 # effective focal length (m)
pix = 4e-6 # effective screen pixel (m)
Cfac = 1.0 # order-unity edge-coupling prefactor C of Equation (4); geometric scale C = 1
.
def r_gamma(lam_nm):
"""Circulation radius = reduced wavelength, in metres."""
return lam_nm * 1e-9/(2 * np.pi)
.
# ---------------- (1) Fig. 1 ----------------
def slit_intensity(x, a, helicity=+1, shifted=True):
"""Far-field single-slit intensity for one helicity component.
The circulation-phase ramp has total differential phase C*2*pi*r_gamma/a across the
aperture; its sign follows the circulation sense, i.e. the photon helicity."""
kx = 2 * np.pi * x/(lam * f)
kap = helicity * Cfac * (2 * np.pi * r_gamma(lam * 1e9)/a)/a if shifted else 0.0
v = (kx - kap) * a/2
return np.sinc(v/np.pi) ** 2
.
def linear_pol_intensity(x, a):
""" Appendix A.6 : linear polarization = equal incoherent superposition of the two
helicity-shifted patterns; centroid must vanish identically."""
return 0.5 * slit_intensity(x, a, +1) + 0.5 * slit_intensity(x, a, -1)
.
def linpol_null_demo(a_um=2):
a = a_um * 1e-6
x1 = lam * f/a
x = np.linspace(-3 * x1, 3 * x1, 200001)
Il = linear_pol_intensity(x, a)
centroid = np.trapezoid(x * Il, x)/np.trapezoid(Il, x)
dx = Cfac * r_gamma(lam * 1e9)/a * x1
print(f"lin-pol null: centroid = {centroid*1e6:+.2e} um "
f"(single-helicity shift {dx*1e3:.2f} mm) -> net translation zero")
.
def fig1(a_um=2, savepath='fig1.png'):
"""Optional: regenerate Fig. 1 of the main text (requires matplotlib; the rest of
the script needs numpy only). (a) helicity-resolved far-field patterns at
lambda = 633 nm, a = 2 um, f = 0.25 m, with a log-scale inset of the first
minimum; (b) predicted fractional shift |Dx|/X = C r_gamma/a versus wavelength
for a = 1, 2, 5, 10 um, with an ordinary diffractive phase reference (1/lambda).
Not run by default; call fig1() explicitly."""
import matplotlib
matplotlib.use('Agg')
import matplotlib.pyplot as plt
plt.rcParams.update({'font.size': 7, 'axes.titlesize': 8,
'axes.labelsize': 8, 'xtick.labelsize': 7,
'ytick.labelsize': 7})
a = a_um * 1e-6
x1 = lam * f/a
x = np.linspace(-2 * x1, 2 * x1, 40001)
I0 = slit_intensity(x, a, shifted=False)
Ip = slit_intensity(x, a, helicity=+1)
Im = slit_intensity(x, a, helicity=-1)
fig, ax = plt.subplots(1, 2, figsize=(7.0, 2.9))
ax[0].plot(x/x1, I0, 'k-', lw=1.4, label='standard (k = 0)')
ax[0].plot(x/x1, Ip, '--', color='crimson', lw=1.2, label='sigma+')
ax[0].plot(x/x1, Im, '-.', color='teal', lw=1.2, label='sigma-')
ax[0].set(xlim=(-2, 2), ylim=(0, 1.02), xlabel='x/x1 (x1 = lambda f/a)',
ylabel='normalized intensity',
title='(a) helicity-resolved far-field patterns')
ax[0].legend(fontsize=6.5, frameon=False, loc='lower left')
axi = ax[0].inset_axes([0.40, 0.40, 0.36, 0.55])
for I, sty, c in ((I0, '-', 'k'), (Ip, '--', 'crimson'), (Im, '-.', 'teal')):
axi.plot(x/x1, I, sty, color=c, lw=1.0)
axi.set(xlim=(0.75, 1.25), ylim=(1e-6, 3e-2), yscale='log',
title='first minimum')
axi.title.set_fontsize(7)
axi.tick_params(labelsize=6)
lam_nm = np.linspace(350, 720, 200)
for au, c in ((1, 'k'), (2, 'crimson'), (5, 'teal'), (10, 'olive')):
frac = Cfac * r_gamma(lam_nm)/(au * 1e-6) * 100
ax[1].plot(lam_nm, frac, color=c, lw=1.4, label=f'a = {au} um')
ax[1].plot(lam_nm, 2.8 * (633.0/lam_nm), ':', color='gray', lw=1.2,
label='ordinary phase ~ 1/lambda')
ax[1].set(yscale='log', xlabel='lambda (nm)', ylabel='|Dx|/X (%)',
title='(b) predicted shift scaling (C = 1)')
ax[1].legend(fontsize=6.5, frameon=False, loc='center right')
fig.tight_layout()
fig.savefig(savepath, dpi=300)
print(f'fig1: wrote {savepath}')
.
# ---------------- (2) Fisher error budget (Table 4) ----------------
def fisher_sigma(a, N):
"""Per-frame translation precision, full pattern:
sigma(Dx) = (lam f/2 pi a) sqrt(3/N), from F = 4 pi^2 a^2/(3 (lam f)^2) per photon
(using (g')^2/g = 4 h'^2 for g = sinc^2 = h^2 and int (sinc')^2 dv = pi/3)."""
x1 = lam * f/a
return x1/(2 * np.pi) * np.sqrt(3.0/N)
.
def table4():
for a_um in (1, 2, 5, 10):
a = a_um * 1e-6
rg = r_gamma(lam * 1e9)
x1 = lam * f/a
shift = Cfac * rg/a * x1
s6 = fisher_sigma(a, 1e6)
print(f"a={a_um:>2} um shift={shift*1e3:6.2f} mm sigma/frame={s6*1e6:6.1f} um "
f"frac/frame={s6/shift*100:5.2f}% 50-frame={s6/np.sqrt(50)/shift*100:5.3f}%")
.
# ---------------- (3) Monte Carlo end-to-end validation ----------------
def mc_screen(a_um, N, nrep=150, mode='signal', rough_rms=0.0, seed=7, C=None):
"""End-to-end: pattern generation -> Poisson + readout noise -> iterative
matched-filter (Fisher-scoring) translation estimator with truncated ML weights.
mode: 'signal' | 'null' | (rough_rms>0 adds smooth multiplicative gain/roughness).
The estimator runs on a single-helicity frame; the helicity-difference channel of the
experiment subtracts two such frames, doubling the signal and adding the independent
channel noises in quadrature (Appendix B, remark)."""
Cv = Cfac if C is None else C # helicity coupling sign/magnitude
rng = np.random.default_rng(seed)
a = a_um * 1e-6
rg = r_gamma(lam * 1e9)
x1 = lam * f/a
shift_true = Cv * rg/a * x1
xc = 0.0 if mode == 'null' else shift_true
x = np.arange(xc - 1.5 * x1, xc + 1.5 * x1, pix)
n = len(x)
kx = 2 * np.pi * x/(lam * f)
kap = Cv * 2 * np.pi * rg/a**2
.
def pat(kappa):
v = (kx - kappa) * a/2
I = np.sinc(v/np.pi) ** 2
return I/I.sum()
.
tmpl = pat(0.0)
Idata = pat(0.0 if mode == 'null' else kap)
if rough_rms > 0: # one independent distortion realization per seed
knots = 31
Idata = Idata * np.interp(x, np.linspace(x[0], x[-1], knots),
rng.normal(1.0, rough_rms, knots))
true = 0.0 if mode == 'null' else shift_true
freqs = fft.rfftfreq(n)
FT = fft.rfft(tmpl)
FTd = fft.rfft(np.gradient(tmpl, pix))
ests = np.empty(nrep)
for r in range(nrep):
cnt = np.clip(rng.poisson(Idata * N) + rng.normal(0, 3.0, n), 0, None)
D = 0.0
for _ in range(6):
ph = np.exp(-2j * np.pi * freqs * D/pix)
cur = np.real(fft.irfft(FT * ph, n))
dcur = -np.real(fft.irfft(FTd * ph, n))
mu, dm = N * cur, N * dcur
w = 1.0/np.maximum(mu, 10.0) # truncated ML weights
D += np.clip(np.sum((cnt - mu) * dm * w)/np.sum(dm * dm * w),
-0.3 * x1, 0.3 * x1)
ests[r] = D
return ests, true
.
def rough_ensemble(a_um=2, N=1e6, nfields=40, nrep=20, rough_rms=0.02, seed0=101):
"""Appendix D (v7): ensemble over independent smooth-distortion realizations.
Each field = one draw of the 31-knot smooth gain field (2% rms); nrep estimator
repetitions per field average down photon noise so the per-field bias isolates the
distortion-induced spurious translation."""
biases = np.empty(nfields)
for i, s in enumerate(range(seed0, seed0 + nfields)):
ests, true = mc_screen(a_um, N, nrep=nrep, mode='signal',
rough_rms=rough_rms, seed=s)
biases[i] = ests.mean() - true
frac = np.abs(biases)/true * 100
print(f"rough ensemble: {nfields} fields x {nrep} reps, {rough_rms*100:.0f}% rms, 31 knots")
print(f" |spurious|/shift: median={np.median(frac):.2f}% mean={frac.mean():.2f}% "
f"max={frac.max():.2f}%")
print(f" sign distribution: +{(biases > 0).sum()}/-{(biases < 0).sum()} "
f"ensemble mean = {biases.mean()/true*100:+.2f}% of shift")
.
def paired_differential_demo(a_um=2, N=1e6, npair=150):
"""Appendix C: paired helicity-difference check. Each pair = one sigma+ frame
(C=+1) and one sigma- frame (C=-1), N photons each; the experimental estimate is
(est+ - est-)/2. Expectation: the two independent channel noises add in quadrature
against a doubled signal, so per-pair sigma(dx) = single-channel sigma/sqrt(2),
i.e. the fractional precision of Table 4 is unchanged at fixed total photon number."""
e_plus, true = mc_screen(a_um, N, nrep=npair, mode='signal', seed=7, C=1.0)
e_minus, _ = mc_screen(a_um, N, nrep=npair, mode='signal', seed=8, C=-1.0)
d = (e_plus - e_minus)/2.0
print(f'paired differential: per-pair sigma(dx)={d.std()*1e6:.1f} um '
f'(single-channel {e_plus.std()*1e6:.1f} um, expected ratio 1/sqrt(2) '
f'= {e_plus.std()/np.sqrt(2)*1e6:.1f} um), bias={(d.mean()-true)*1e6:+.2f} um')
.
if __name__ == '__main__':
print('--- Table 4 (Fisher) ---')
table4()
print('--- Appendix A.6 ---')
linpol_null_demo()
e, t = mc_screen(2, 1e6, mode='signal')
print(f'signal: sigma={e.std()*1e6:.1f} um bias={(e.mean()-t)*1e6:+.1f} um '
f'(full-pattern Fisher 21.8 um, on-support 23.7 um)')
e0, _ = mc_screen(2, 1e6, nrep=800, mode='null')
s0 = e0.std()
print(f'null : sigma={s0*1e6:.1f} um bias={e0.mean()*1e6:+.2f} um '
f'max|est|={np.abs(e0).max()/s0:.2f} sigma (nrep=800, Appendix C)')
paired_differential_demo()
rough_ensemble()

References

  1. Glauber, R.J. The quantum theory of optical coherence. Phys. Rev. 1963, 130, 2529–2539. [Google Scholar] [CrossRef]
  2. Taylor, G.I. Interference fringes with feeble light. Proc. Camb. Philos. Soc. 1909, 15, 114–115. [Google Scholar]
  3. Grangier, P.; Roger, G.; Aspect, A. Aspect, Experimental evidence for a photon anticorrelation effect on a beam splitter: A new light on single-photon interferences. Europhys. Lett. 1986, 1, 173–179. [Google Scholar] [CrossRef]
  4. Hawton, M. Photon position operator with commuting components. Phys. Rev. A 1999, 59, 954–959. [Google Scholar] [CrossRef]
  5. Cheng, J.; Cheng, D. The spiral structure model: A geometric phenomenology of wave-particle duality, spin, and electromagnetic coupling. Preprints 2026, preprint. [Google Scholar] [CrossRef]
  6. Cheng, J.; Cheng, D. The natural philosophical nature of light: A hypothesis of energetic mass points in uniform spiral linear motion in space. Preprints 2026, preprint. [Google Scholar] [CrossRef]
  7. Cheng, J.; Cheng, D. Toward the dynamics of the spiral structure model: Canonical quantization, core electrodynamics, and the defect propagator. Preprints 2026, preprint. [Google Scholar] [CrossRef]
  8. Einstein, A. Über einen die Erzeugung und Verwandlung des Lichtes betreffenden heuristischen Gesichtspunkt. Ann. Phys. 1905, 322, 132–148. [Google Scholar] [CrossRef]
  9. Compton, H. A quantum theory of the scattering of X-rays by light elements. Phys. Rev. 1923, 21, 483–502. [Google Scholar] [CrossRef]
  10. Beth, R.A. Mechanical detection and measurement of the angular momentum of light. Phys. Rev. 1936, 50, 115–125. [Google Scholar] [CrossRef]
  11. Bohm, D. A suggested interpretation of the quantum theory in terms of “hidden” variables. I Phys. Rev. 1952, 85, 166–179. [Google Scholar] [CrossRef]
  12. Miyamoto, K.; Wolf, E. Generalization of the Maggi–Rubinowicz theory of the boundary diffraction wave. Part I. J. Opt. Soc. Am. 1962, 52, 615–625. [Google Scholar] [CrossRef]
  13. Pancharatnam, S. Generalized theory of interference, and its applications. Part I. Coherent pencils. Proc. Indian Acad. Sci. A 1956, 44, 247–262. [Google Scholar] [CrossRef]
  14. Berry, M.V. Quantal phase factors accompanying adiabatic changes. Proc. R. Soc. Lond. A 1984, 392, 45–57. [Google Scholar] [CrossRef]
  15. Sztul, H.I.; Alfano, R.R. Double-slit interference with Laguerre–Gaussian beams. Opt. Lett. 2006, 31, 999–1001. [Google Scholar] [CrossRef]
  16. Giovannetti, V.; Lloyd, S.; Maccone, L. Quantum-enhanced measurements: Beating the standard quantum limit. Science 2004, 306, 1330–1336. [Google Scholar] [CrossRef]
  17. Caves, M. Quantum-mechanical noise in an interferometer. Phys. Rev. D. 1981, 23, 1693–1708. [Google Scholar] [CrossRef]
  18. Hadfield, R.H. Single-photon detectors for optical quantum information applications. Nat. Photonics 2009, 3, 696–705. [Google Scholar] [CrossRef]
  19. Eisaman, M.D.; Fan, J.; Migdall, A.; Polyakov, S.V. Invited review article: Single-photon sources and detectors. Rev. Sci. Instrum. 2011, 82, 071101. [Google Scholar] [CrossRef]
  20. Maggi, G.A. Sulla propagazione libera e perturbata delle onde luminose in un mezzo isotropo. Ann. Mat. 1888, 16, 21–48. [Google Scholar] [CrossRef]
  21. Rubinowicz, A. Zur Kirchhoffschen Beugungstheorie. Ann. Phys. 1924, 73, 339–364. [Google Scholar] [CrossRef]
Table 1. Exclusion summary. The operative discriminator is the joint signature, not any one property.
Table 1. Exclusion summary. The operative discriminator is the joint signature, not any one property.
Candidate Standard Effect ∝ λ? ∝ 1/a? Rigid Shift? Helicity-odd? Reason for Exclusion
Path-difference phase No (∝ 1/λ) No Tilt only No Wrong wavelength scaling; cancels differentially
Gouy phase No (slow, via zR) No No No No a dependence; curvature only
Boundary-diffraction wave Envelope only No No No No linear aperture ramp
Envelope rescaling Width only Rescales No No Center fixed at xf = 0
Edge spin–orbit coupling (SPP/IF) No (∝ 1/λ phases) No No Yes (near-field) Localized, material-dependent; bounded by material variants and FDTD
Pancharatnam–Berry phase Achromatic No Yes Yes Needs an anisotropy axis; fails ∝ λ
Orbital angular momentum Set by incident ℓ No Comb only No ℓ = 0 illumination; modal spectrum verified
Grating/SLM ramp Groove density No Yes Static Masks are passive and non-periodic
Table 2. Signal budget (C = 1). The last four columns give |Δx|/X.
Table 2. Signal budget (C = 1). The last four columns give |Δx|/X.
λ (nm) rγ = λ/2π (nm) δφ at a = 1 μm (rad) a = 1 μm a = 2 μm a = 5 μm a = 10 μm
405 64.5 0.405 6.4% 3.2% 1.3% 0.64%
532 84.7 0.532 8.5% 4.2% 1.7% 0.85%
633 100.7 0.633 10.1% 5.0% 2.0% 1.0%
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.
Copyright: This open access article is published under a Creative Commons CC BY 4.0 license, which permit the free download, distribution, and reuse, provided that the author and preprint are cited in any reuse.