Preprint
Article

This version is not peer-reviewed.

Advanced Control Techniques for Wide-Speed-Range Sensorless Permanent Magnet Motor Drives

Submitted:

29 October 2026

Posted:

30 October 2026

You are already at the latest version

Abstract
Permanent Magnet Synchronous Motor (PMSM) drives employing sensorless control offer reduced cost, improved reliability and increased power density by eliminating mechanical position sensors. However, reliable operation from standstill to the field-weakening region remains challenging because of startup synchronization difficulties, electromechanical oscillations, and rotor position estimation errors at high speeds. This paper proposes an Integrated Wide-Speed Sensorless Control Framework (IWSSCF) for wide-speed-range PMSM drives combining a low-loss closed-loop startup algorithm, an Electromechanical Oscillation Angle Compensation (EOAC) technique, a flux-observer-based Field-Oriented Control (FOC) scheme, and a stable field-weakening algorithm. During startup, the proposed controller minimizes the torque-producing current according to the estimated mechanical power demand while maintaining synchronization. The EOAC algorithm suppresses torque-angle oscillations and enables a smooth transition from open-loop to closed-loop sensorless operation, whereas the field-weakening strategy improves high-speed stability by mitigating the effects of transient rotor angle estimation errors. The proposed methodology is evaluated through detailed discrete-time simulations and validated experimentally using a laboratory PMSM drive. The obtained results demonstrate improved startup reliability, reduced power consumption, lower electromechanical oscillations and stable operation over the entire operating speed range. The proposed control framework therefore provides an efficient and robust sensorless solution for high-performance PMSM drive applications.
Keywords: 
;  ;  ;  ;  ;  ;  ;  ;  ;  

1. Introduction

The increasing electrification of transportation, industrial automation, renewable energy conversion systems, and marine propulsion has significantly accelerated the adoption of PMSMs in variable-speed drive applications. Owing to their high-power density, superior efficiency, fast dynamic response, and compact construction, PMSMs have gradually replaced conventional induction motor drives in numerous high-performance applications requiring precise torque and speed regulation. Their widespread utilization in electric vehicles, marine propulsion systems, robotics, compressors, pumps and servo drives has consequently stimulated extensive research on advanced control techniques capable of maximizing system performance while maintaining high reliability and energy efficiency [1,2,3,4,5].
FOC has become the dominant control strategy for high-performance PMSM drives because it enables the independent regulation of torque- and flux-producing current components, allowing the machine to exhibit dynamic characteristics comparable to separately excited dc motors [6,7,8]. The successful implementation of FOC, however, requires accurate knowledge of the rotor electrical position and speed. Traditionally, this information is obtained using mechanical position sensors, such as optical encoders or resolvers. Although these devices provide high measurement accuracy, they inevitably increase the overall system cost, installation complexity and maintenance requirements while reducing reliability in harsh operating environments characterized by vibration, humidity, dust or elevated temperatures [9,10]. Consequently, sensorless control techniques have attracted considerable attention during the last two decades as an attractive alternative for eliminating mechanical position sensors without compromising the dynamic performance of the drive system.
Several sensorless PMSM control techniques have been proposed in the literature, each exhibiting different advantages depending on the operating speed range and application requirements. High-frequency signal injection methods exploit the magnetic saliency of the machine and provide excellent position estimation capability at zero and very low speeds; however, they increase acoustic noise, torque ripple and computational complexity while their effectiveness depends strongly on machine saliency characteristics [11,12,13]. Model-based approaches, including back-electromotive-force (Back-EMF) observers, stator-flux observers, Model Reference Adaptive Systems (MRAS), sliding-mode observers and Extended Kalman Filters (EKF), estimate the rotor position from the measured stator voltages and currents without requiring additional signal injection [14,15,16,17,18,19]. These techniques generally provide excellent performance at medium and high speeds and therefore constitute the preferred solution for numerous industrial applications because of their relatively simple implementation and low computational burden. Among them, stator-flux observers have gained particular attention owing to their robustness, fast dynamic response and suitability for implementation in embedded digital controllers.
Despite the considerable progress achieved in sensorless PMSM control, reliable operation over the complete speed range, extending from standstill to the maximum operating speed in the field-weakening region, remains a challenging research problem. The principal limitation originates from the absence of measurable back-EMF at zero or very low rotor speeds, where conventional observer-based estimation techniques cannot accurately determine the rotor electrical position [20,21]. As a consequence, practical sensorless drives commonly employ an open-loop startup procedure that aligns the rotor and subsequently accelerates the machine using an externally generated electrical angle until sufficient back-EMF is developed for the observer to operate reliably. Although this methodology is widely adopted in commercial drives because of its simplicity, it generally requires conservative current references to guarantee synchronization under unknown loading conditions. The excessive startup current increases copper losses, converter losses and battery energy consumption, while simultaneously generating significant torque pulsations and electromechanical oscillations that may deteriorate the dynamic performance of the drive system.
The transition from open-loop startup to closed-loop sensorless operation represents another critical operating condition. During this transition, the estimated electrical angle generated by the observer gradually replaces the imposed open-loop electrical angle. Any discrepancy between these two quantities may produce abrupt torque variations, transient current overshoots and mechanical oscillations, particularly in applications characterized by large inertial loads or rapidly varying torque demands [22,23,24,25]. In severe operating conditions, the resulting angle mismatch may even lead to loss of synchronization, startup failure or activation of the converter protection functions. Consequently, ensuring a smooth and reliable transition between open-loop and closed-loop operation has become one of the key challenges in the development of high-performance sensorless PMSM drives.
Additional challenges arise when PMSMs operate above their base speed in the field-weakening region. In this operating mode, the controller intentionally applies negative d-axis current to reduce the resultant stator flux, thereby allowing the motor to operate beyond the rated voltage limit imposed by the inverter. Under these conditions, the sensitivity of the torque control loop to rotor angle estimation errors increases considerably, making the overall sensorless control system more susceptible to oscillatory behaviour and instability [26,27,28]. Recent studies have demonstrated that transient rotor angle estimation errors directly affect the produced electromagnetic torque, modifying the closed-loop dynamics and reducing the stability margins of the complete drive system [29]. Consequently, stable field-weakening operation has become an essential requirement for modern high-speed sensorless PMSM applications.
Although numerous studies have investigated startup strategies, sensorless observers, transition algorithms or field-weakening control individually, relatively few contributions have addressed the complete operating range using a unified sensorless control architecture. In many practical implementations, these functions are designed independently, resulting in limited coordination between the startup controller, the observer, the transition logic and the high-speed control strategy. Such an approach may compromise overall system robustness, increase implementation complexity and reduce operating efficiency under varying load and speed conditions. Therefore, the development of an integrated sensorless control methodology capable of ensuring reliable operation from standstill to maximum speed remains an important research objective.
Our previous research has progressively addressed several of these individual challenges. Initially, a low-loss startup strategy based on closed-loop output power regulation was proposed to minimize the startup current while maintaining reliable synchronization under variable loading conditions [30]. Subsequently, an EOAC technique was developed to suppress startup oscillations and improve the transition between open-loop and closed-loop sensorless operation by compensating the rotor angle deviations associated with the mechanical dynamics of the drive system [31]. Furthermore, the instability mechanism of sensorless PMSM drives operating in the field-weakening region has been extensively investigated in [29], where the influence of transient rotor angle estimation errors on torque regulation and closed-loop stability was analytically demonstrated. These studies constitute complementary contributions that individually improve specific operating regions of the sensorless drive but do not provide a unified solution covering the entire operating speed range.
Building upon these developments, this paper proposes an IWSSCF for PMSM drives that extends the above methodologies within a single coordinated control architecture. The proposed framework incorporates a closed-loop low-loss startup controller, an EOAC algorithm, a stator-flux-observer-based sensorless FOC strategy including a stable field-weakening controller into a unified implementation that ensures smooth operation from standstill to maximum speed, employing constant torque and constant power operating regions. Compared with existing approaches, the proposed framework coordinates the interaction between the individual control functions, thereby improving startup efficiency, reducing electromechanical oscillations, enabling seamless transition to closed-loop sensorless operation and extending the stable operating region under field-weakening conditions.
The effectiveness of the proposed control framework is evaluated using a detailed discrete-time simulation model and experimentally validated on a laboratory PMSM drive prototype representative of high-performance propulsion applications. The obtained results demonstrate significant improvements in startup reliability, reduction of power consumption and torque oscillations, smoother transition to closed-loop operation and enhanced stability throughout the complete operating speed range. The proposed methodology therefore constitutes a practical and computationally efficient solution for wide-speed-range sensorless PMSM drives requiring high efficiency, robustness and reliable operation.
The remainder of this paper is organized as follows. Section 2 presents the mathematical model of the PMSM and describes the characteristics of the target sensorless drive application. Section 3 introduces the proposed IWSSCF, including the low-loss startup strategy, seamless transition methodology, flux-observer-based sensorless field-oriented control, and stable field-weakening controller. Section 4 describes the simulation methodology, parameter selection, simulation and experimental validation results. Finally, Section 5 summarizes the main conclusions of this paper.

2. PMSM Modeling and Application Characteristics

2.1. Mathematical Model of PMSM

The stator voltage equations of the PMSM expressed in the synchronous dq-reference frame are expressed as follows:
V d = R s i d + L d di d dt - ω e L q i q
V q = R s i q + L q di q dt + ω e L d i d + ω e ψ mag
where V d , V q are d-q stator voltages, i d , i q are the d-q stator currents, L d , L q are the d-q inductances, R s is the stator resistance, ω e is the electrical angular speed and ψ mag expresses Permanent Magnet (PM) flux linkage.
The relationship of the produced electromagnetic torque for the PMSM is expressed by the following equation:
T e = 3 2 p ψ mag i q + L d - L q i d i q
where T e is the produced electromagnetic torque, and p represents the number of pole pairs of the machine. Typically, in a surface mounted PMSM, L d is almost equal to L q , so reluctance torque term is almost zero. Therefore, in this case (3) can be simplified as follows:
T e = 3 2 p ψ mag i q
The mechanical dynamics of the PMSM drive are described by:
J d ω m dt = T e - T L - B ω m
where J is the rotor inertia, B   is the viscous friction coefficient, ω m is the mechanical rotor angular speed and T L is the load torque. The electrical rotor position θ e and angular speed ω e are related to the mechanical quantities by:
θ e = p θ m
ω e = p ω m
The above relationships (1)-(7) constitute the mathematical foundation for the startup methodology, flux observer and the sensorless field-oriented control strategy developed in the following section.

2.2. Target Drive System and Application Requirements

The proposed control framework has been developed for a variable-speed electric propulsion system intended for watercraft applications. Such systems require a robust sensorless startup strategy capable of producing high starting torque, particularly under adverse operating conditions, such as increased propeller loading caused by aquatic vegetation or debris. In addition, the controller must enable rapid acceleration to the rated operating speed while ensuring a smooth and reliable transition from open-loop startup to closed-loop sensorless FOC. Although these requirements are motivated by marine propulsion, similar operating conditions are encountered in many variable-speed fan and pump drive applications.
The main specifications of the PMSM and the corresponding controller are summarized in Table 1, while the rated and temporary overload torque-speed characteristics of the selected PMSM are illustrated in Figure 1. More specifically, Figure 1 shows that the manufacturer's torque-speed characteristic is limited to the rated operating region and does not consider operation in the field-weakening (constant-power) region. Consequently, one of the primary objectives of the proposed control framework is to maximize the usable speed range beyond the rated speed through stable sensorless field-weakening control. As listed in Table 1, the target propulsion system utilizes a surface-mounted PMSM with a 10-pole/12-slot Fractional-Slot Concentrated Winding (FSCW) configuration, which provides a compact and high-torque solution suitable for variable-speed propulsion applications [2].
Table 1 also summarizes the principal control parameters adopted throughout this work. The Pulse Width Modulated (PWM) inverter, current controller, sensorless angle estimator, and speed observer are all executed at a sampling frequency of 16 kHz to provide accurate current regulation and rotor position estimation. In contrast, the speed controller, field-weakening controller, open-loop torque estimator, and EOAC operate at 1 kHz, which is sufficient for the slower mechanical dynamics while reducing the computational burden. The design and implementation of these control modules are presented in detail in Section 3.

3. Proposed Integrated Wide-Speed Sensorless Control Framework

3.1. Overall Control Architecture

The proposed IWSSCF is designed to achieve reliable motor operation from standstill to speeds above the rated value. The control system combines an open-loop high efficiency startup strategy, an EOAC controller, a transition mechanism, flux-observer-based sensorless field-oriented control, and field-weakening operation within a unified architecture. An overall block diagram of the proposed methodology is illustrated in Figure 2.
The overall control structure consists of a high-bandwidth inner current-control loop implemented in the synchronous d - q reference frame, an outer speed-control loop, and a sensorless estimation layer that provides the rotor electrical position and speed required for closed-loop operation. The field-weakening controller modifies the d-axis current reference when the maximum stator voltage based on the available dc-link voltage and PWM strategy becomes insufficient to maintain the commanded operating point above the base speed.
The motor drive operation is divided into three principal regions. During the first region, the motor is accelerated using the open-loop startup algorithm, while the open-loop torque estimator and EOAC algorithm improve the motor drive efficiency, transient response and suppress electromechanical oscillations. In the second region, the transition algorithm evaluates the required switching conditions and synchronizes the open-loop reference variables with the estimated rotor position and speed. Once the transition criteria are satisfied, the drive enters the third region, in which closed-loop sensorless FOC regulates the speed throughout the rated-speed and field-weakening operating ranges.
To accommodate the different dynamic characteristics of the control functions, the proposed framework employs a multirate digital implementation. The PWM generation, current controller, sensorless angle estimator, and speed observer operate at 16 kHz, compensating between low current harmonic content, torque ripple and motor drive losses [32] whereas the speed controller, field-weakening controller, open-loop torque estimator, and EOAC are executed at 1 kHz. The individual control modules and their operating principles are described in the following subsections.

3.2. Integrated Low-Loss and Reliable Sensorless Startup Strategy

Reliable startup remains one of the principal challenges in sensorless PMSM drives because accurate rotor position information cannot be obtained from conventional back-EMF or flux-observer techniques at standstill and very low rotational speeds. Consequently, the drive must initially operate in an open-loop mode until sufficient rotor speed is developed for stable sensorless estimation. Conventional startup methods typically employ a constant torque-current reference selected according to the rated motor current to guarantee synchronization under worst-case loading conditions. Although robust, this approach introduces excessive copper and converter losses under light-load conditions and may excite electromechanical oscillations during aggressive acceleration or rapidly varying mechanical loads.
To overcome these limitations, the proposed IWSSCF incorporates an integrated startup strategy consisting of three coordinated functions: (i) an open-loop sensorless startup algorithm, (ii) a loss-minimization current regulation scheme, and (iii) an EOAC algorithm. The interaction of these control modules enables efficient startup with reduced current demand, improved dynamic stability, and reliable preparation for the subsequent transition to closed-loop sensorless FOC.

3.2.1. Open-Loop Startup Principle

Following a startup command, the controller first performs rotor alignment in d-axis by injecting a stationary stator current to establish a known electrical rotor position. After the alignment interval, the synchronous rotating reference frame is advanced by 90 ∘ electrical and accelerated according to a predefined configured acceleration profile. During this operating stage, the d-axis current reference is maintained equal to zero, while the q-axis current generates the required electromagnetic torque. Since the rotor position estimation for flux observer is not yet reliable, the electrical angle supplied to the current controller is obtained by integrating the commanded electrical speed.
The commanded referenced mechanical speed ω m , OL * is calculated as follows:
ω m , OL * t = ω m , 0 * + a OL t
where a OL denotes the configured startup acceleration. The corresponding electrical angle θ e , OL * is calculated as follows:
θ e , OL * t = mod θ e , 0 , + ∫ 0 t p ω m , OL * d τ , 2 π
where p   is the number of pole pairs and θ e , 0 is the electrical angle established during rotor alignment. Because the controller operates in the imposed rotating reference frame, a torque-angle displacement θ L naturally develops between the imposed electrical angle and the actual rotor position,
θ L = θ e , OL - θ e
For the surface-mounted PMSM considered in this work, the reluctance torque is negligible, and the produced electromagnetic torque, following (4) can be approximated by:
T e = K t i q , OL * cos θ L
where K t denotes the motor torque constant. Equation (11) demonstrates that any variation of the torque angle directly affects the produced torque and consequently the mechanical speed during startup. Figure 3 illustrates the relationship between the synchronous rotating d q reference frame and the actual rotor d ′ q ′ reference frame during open-loop startup.

3.2.2. Loss-Minimization Current Regulation

Unlike conventional open-loop startup techniques employing a constant current reference, the proposed methodology continuously adapts the commanded q-axis current according to the instantaneous mechanical power demand. As a result, the startup current remains sufficiently high to preserve synchronization while avoiding unnecessary copper and converter losses under reduced loading conditions. In order to overcome this issue, a torque current estimator has been developed, based on the actual output motor power and the commanded one. Moreover, in order to enhance the fastness and stability of the estimator, the required acceleration torque is estimated through a feedforward term derived from the mechanical dynamics,
i q , FF * = J   d ω m , OL * dt + B ω m , OL * K t
where J   and B   denote the equivalent inertia and viscous-friction coefficient, respectively.
The actual motor output power is estimated from the measured dc-link input power after subtracting the calculated converter P ^ conv and copper P ^ cu losses,
P ^ m = V dc I dc - P ^ conv - P ^ cu
The converter losses consist primarily of conduction and switching losses. Since these losses are difficult to calculate analytically in real time, they can be represented by an experimentally identified polynomial function of the dc-link current,
P ^ conv = k 1 V dc I dc + k 2 I dc 2
where k 1 and k 2 are experimentally identified coefficients that account for the combined switching and conduction losses of the inverter. The copper losses are calculated as follows, considering that in the startup strategy the d-axis current is equal to zero:
P ^ cu = 3 2 R s i q 2
where R s expresses the phase stator resistance. The corresponding reference output power is:
P m * = K t i q * ω m , OL *
Based on the above motor output power parameters, a Proportional-Integral (PI) regulator is utilized in order to match the reference commanded output power with the estimated one, generating the corrective current component i q , PI * .
The PI gains of the startup power regulator were selected considering the nonlinear characteristics of the startup process. Unlike conventional linear control systems, the relationship between the commanded q-axis current and the estimated mechanical output power varies continuously during startup because the mechanical power depends simultaneously on both the developed torque and the instantaneous rotor speed, according to (16). Consequently, an analytical controller design based on a fixed plant transfer function is not directly applicable. To ensure robust operation, the power regulation loop was designed with a significantly lower bandwidth than the inner current controller, allowing the current loop to be regarded as substantially faster than the outer power loop. Under this assumption, the proportional gain was initially selected to obtain a rapid but non-oscillatory response of the estimated output power to variations in the q-axis current command. The integral gain was subsequently increased to eliminate steady-state power regulation errors while maintaining stable synchronization throughout the acceleration interval. The controller gains were finally refined experimentally over the complete startup operating range, including no-load and rated-load conditions, until a satisfactory compromise was achieved between power tracking accuracy, startup-current reduction, oscillation suppression, and reliable synchronization.
Finally, the startup current reference is calculated as follows:
i q , OL * = i q , FF * + i q , PI * + i q , off
where i q , off   denotes a small stabilizing current offset, equal to 10% of the rated motor current, that guarantees sufficient synchronizing torque throughout the startup interval. The block diagram of the proposed low speed range loss minimization algorithm is illustrated in Figure 4.

3.2.3. Electromechanical Oscillation Attenuation

During rapid acceleration or highly variable mechanical loading, fluctuations of the torque angle may excite low-frequency electromechanical oscillations. These oscillations increase speed ripple, degrade transition performance, and may eventually result in startup failure. To improve startup robustness, the proposed controller incorporates an EOAC technique, which estimates the oscillatory component of the torque angle from the measured motor output power.
Assuming the ideal startup condition corresponds to zero oscillatory torque-angle deviation, the ideal motor output power is expressed as follows:
P m , ideal * = K t i q , OL * ω m , OL *
The estimated oscillation angle is then obtained from the following equation, analogous to the power-angle relationship in electrical and mechanical oscillatory systems [31,33].
θ ^ L = cos - 1 P ^ m P m , ideal *
Only the oscillatory component is required for angle compensation. Consequently, the estimated angle is processed through cascaded first order high-pass and low-pass filters,
θ e , comp = G LPF s G HPF s θ ^ L
where the high-pass filter G HPF s removes the steady-state torque-angle component, while the low-pass filter G LPF s suppresses high-frequency estimation noise. The low-pass filter bandwidth is set proportional to the commanded speed. In contrast, the high-pass filter employs a 1.6 Hz cut-off frequency to reject the steady-state DC component. It should be noted that the steady-state torque-angle component is required for the open-loop sensorless self-stabilization mechanism described in 3.2.1. Finally, the compensated electrical angle applied to the drive during startup becomes:
θ e , OL = mod θ e , OL * +   θ e , comp ,   2 π
which actively suppresses electromechanical oscillations without affecting the inherent stability of the open-loop startup process. The block diagram of the proposed EOAC methodology is illustrated in Figure 5.

3.3. Open-Loop to Closed-Loop Transition Methodology

The transition from open-loop startup to closed-loop sensorless control represents one of the most critical operating stages of the proposed IWSSCF, since an unsuccessful transfer may lead to torque disturbances, current transients, or complete loss of synchronism. Although the open-loop startup strategy guarantees stable acceleration from standstill, the electrical angle applied to the current controller is generated independently of the estimated rotor position. Consequently, the transition can only be performed after the sensorless observer has converged sufficiently to provide a reliable estimation of the rotor electrical angle and speed. To ensure a robust transfer, the proposed methodology evaluates three transition conditions. More specifically, the transition is initiated when the following conditions are simultaneously satisfied:
ω m * ≥ ω tr
Δ θ = min   θ ^ e - θ e , OL , 2 π -   θ ^ e - θ e , OL < Δ θ max
Δ ω = ω ^ m - ω m , OL * < Δ ω max
where ω tr denotes the predefined transition speed, θ ^ e and ω ^ m are the electrical angle and mechanical speed estimated by the flux observer. The limits Δ θ max and Δ ω max define the maximum allowable estimation errors for enabling the transition and are selected according to the observer convergence characteristics and the dynamic requirements of the application. These conditions ensure that the observer has converged to the actual rotor position before the feedback loop is closed, thereby minimizing the possibility of synchronization loss.
Once the transition criteria are satisfied, a short synchronization interval of approximately 1 ms is executed. During this interval, the startup current reference is maintained while the integral state of the speed controller is initialized according to the existing operating conditions. This initialization ensures continuity of the control action, preventing abrupt variations in the commanded q-axis current immediately after the closed loop PI speed controller is enabled. Following the synchronization interval, the control authority is transferred to the closed-loop sensorless speed controller. Figure 6 summarizes the proposed startup and transition methodology, illustrating the successive operating stages from rotor alignment to open-loop acceleration and the subsequent transition to closed-loop sensorless operation.

3.4. Closed Loop Wide Speed Range Sensorless FOC

Following the transition methodology presented in the previous section, the proposed IWSSCF enters the closed-loop sensorless operating mode, where the rotor electrical angle is continuously estimated using a voltage-model stator flux observer implemented in the stationary α β   reference frame. The observer calculates the stator flux components from the measured phase currents and the commanded inverter voltages according to the following equations:
ψ ^ α =   ∫ V α - R s i α dt - L s i α
ψ ^ β = ∫ V β - R s i β dt - L s i β
where V α and V β denote the applied stator voltages, i α and i β   are the measured motor currents and L s is the stator inductance, which is equal to Ld and Lq in our application. The estimated stator flux vector is subsequently converted into polar coordinates, providing the instantaneous electrical angle utilizing the following equation:
θ f = tan - 1 ψ ^ β ψ ^ α
which represents the raw output of the flux estimator. Although the estimated flux angle accurately follows the rotor position, it inherently contains high-frequency disturbances originating from inverter switching, current measurement noise and numerical integration errors. Consequently, the raw flux angle is not directly supplied to the field-oriented controller but is processed by the proposed dual-phase locked loop (PLL) estimation structure combined with a feedforward correction for high speeds, which is derived from the conventional PLL-based observer framework commonly employed in sensorless PMSM drives [29,34].
The first stage consists of a speed PLL, which estimates the electrical angular velocity from the phase error between the instantaneous flux angle and the internally estimated electrical angle. The phase error is processed by a PI regulator to generate the estimated electrical speed, as shown in Figure 7. Since the electrical speed is obtained directly from the PLL rather than through numerical differentiation of the estimated flux angle, the proposed approach inherently suppresses quantization noise and high-frequency ripple, resulting in smoother speed estimation and improved robustness of the outer speed-control loop.
The estimated electrical speed is subsequently employed by a second angle PLL, which generates the electrical angle utilized by the Park and inverse Park transformations. In addition to the estimated electrical speed, this angle PLL employs a proportional correction term acting on the instantaneous phase error. The proportional correction accelerates the convergence of the estimated electrical angle while preserving a smooth observer response. Consequently, the generated electrical angle simultaneously exhibits low ripple and rapid dynamic tracking, making it suitable for high-performance sensorless field-oriented control.
The proportional gain of the angle PLL directly determines the observer bandwidth and therefore represents one of the most influential tuning parameters of the proposed controller. Low values of K p , PLL provide superior attenuation of switching noise and measurement disturbances but introduce additional phase lag between the estimated and actual rotor positions. Conversely, increasing the proportional gain improves the observer dynamic response and reduces angle tracking error during rapid speed transients, although excessive gain amplifies high-frequency disturbances. Consequently, the PLL gain represents a compromise between estimation bandwidth and noise rejection and therefore constitutes one of the most influential parameters of the proposed sensorless controller.
Following the sensorless estimation stage, the outer speed controller regulates the motor mechanical speed by generating the torque-producing current reference supplied to the inner current control loop. A PI regulator operating at 1 kHz continuously compares the commanded and estimated motor speeds, producing the q -axis current reference required to compensate load disturbances and speed variations, as illustrated in Figure 8. Throughout the constant-torque operating region, the d -axis current reference remains zero, thereby maximizing the torque-per-ampere characteristic of the surface-mounted PMSM. The resulting current references are subsequently regulated by the high-bandwidth current controllers operating at the PWM frequency of 16 kHz, providing fast electromagnetic torque response while maintaining decoupled control of the d- and q-axis current components.
During flux-weakening operation in sensorless operation, transient angle estimation errors between the actual and estimated rotor positions introduce torque discrepancies that create an undesired feedback path within the control loop, which can shift the control system poles toward instability. This additional feedback can reduce the system's stability margin and, under certain operating conditions, lead to oscillatory or unstable behavior. Increasing the observer bandwidth could alleviate this issue but often comes at the expense of reduced noise immunity, making it an impractical solution for many applications.
To overcome this issue without increasing the position estimator gains and sacrificing noise immunity, a torque feedforward strategy is proposed [29,34] which was adapted and implemented within the developed sensorless control system. The compensation term was derived from the angle difference between the PLL-estimated angle and the flux observer angle, representing the transient angle estimation error. This quantity was converted into an equivalent speed correction and injected into the PLL to compensate the estimation error. In addition, the PLL proportional gain was scheduled during field-weakening operation to further improve stability and eliminate undesired torque transients. The overall PLL adaptations implemented for field weakening operation stability are shown in Figure 7.
When the motor speed exceeds the base operating speed, the increasing back-electromotive force gradually drives the commanded stator voltage towards the inverter voltage limit, requiring operation in the field-weakening region. To extend the achievable speed range while preserving stable sensorless operation, the proposed controller employs a hybrid field-weakening strategy consisting of a feedforward voltage model and a feedback voltage regulator, as depicted in Figure 8. The feedforward component predicts the negative d -axis current required to satisfy the steady-state voltage constraint according to the machine electrical model, while the feedback PI controller compensates parameter uncertainties, dc-link voltage variations, and modelling inaccuracies by regulating the stator voltage utilization. Accordingly, the feedforward current reference is calculated as follows:
i d , FF * = - V s , max 2 -   ω ^ e L q i q 2   - ω ^ e ψ mag ω ^ e L d
where V s , max   is the maximum available stator voltage. The feedforward estimate is subsequently corrected by a voltage PI regulator that compares the maximum available stator voltage with the unsaturated stator voltage command calculated by the current controller, yielding the final d-axis current reference.

4. Results and Discussion

4.1. Simulation Results of the Proposed IWSSCF

A discrete transient simulation model in Simulink has been developed with a sampling frequency of 1.6 MHz, for analysis and evaluation purposes of the proposed controller technique. The supported sampling rates of each control loop, that is current control, speed control, sensorless control are similar to the tabulated ones in Table I. The considered model incorporates an additional encoder sensor running in parallel, for actual motor speed and electric angle evaluation. The following sections present a series of tests, including open-loop evaluations demonstrating the loss minimization technique and angle compensation method, as well as closed-loop tests that highlight significant improvements in angle estimation accuracy and overall control performance achieved through the proposed approach.
Figure 9 presents two distinct scenarios for evaluating the open-loop performance of the conventional and proposed startup methods. The first scenario considers a startup failure of the conventional method following a step increase in the applied torque load from 0 to 1.2 Nm at t = 0.4 sec, while the proposed method successfully achieves startup. Under this demanding load condition, the conventional method is unable to maintain stable operation due to the pronounced electromechanical oscillations that arise during the startup transient. In contrast, the proposed method compensates for these oscillations, allowing the system to successfully complete the startup process.
The second scenario provides a comparison of the dynamic behavior of the two methods under conditions where both achieve successful startup with a constant torque load of 0.2 Nm. In this case, the proposed method exhibits a significantly improved speed response, characterized by substantially reduced oscillations compared with the conventional method. Similar improvements can also be observed in the I q current and error-angle responses, where the proposed method results in smoother and less oscillatory behavior. These results demonstrate the ability of the proposed method to improve the dynamic response of the system while maintaining stable open-loop operation under both demanding and low-load startup conditions.
Figure 10 compares the conventional and proposed methods under open-loop operation with a step change in torque load. The initial loading is 0.2 Nm, which is increased to 1 Nm at t = 0.8 s. During the initial low-load interval, the proposed method progressively reduces the I q current as the applied load does not require the initially higher current level. By reducing I q under these light-load conditions, the proposed method avoids unnecessary current and consequently reduces the associated copper losses, contributing to improved operating efficiency. When the torque load is increased from 0.2 Nm to 1 Nm at t = 0.8 s, a corresponding increase in electromagnetic torque is required to maintain the reference speed. The proposed method therefore increases I q to provide the additional torque demanded by the higher load. A corresponding increase in AC power is also observed following the load transition. Compared with the conventional method, the proposed method exhibits reduced oscillations in the speed and AC power responses, while effectively adapting its operating point to the applied load conditions.
Next a transition test from open-loop to closed-loop has been performed, and the speed, current and transition states of the controller with time are presented in Figure 11. During the open-loop interval, the proposed method exhibits a smoother speed response with significantly reduced oscillations compared with the conventional method. The I q current generated by the proposed method also gradually decreases in accordance with the applied low torque load. As the system approaches the transition point, the predicted I q converges toward the current level required by the actual operating condition. Consequently, only a small variation in I q is observed when the control system transitions to closed-loop operation and the PI controller becomes active. This behavior indicates that the I q predicted by the proposed method is closely matched to the current demanded by the system under closed-loop operation.
The reduced I q discontinuity at the open-loop-to-closed-loop transition contributes to a smoother transfer between the two operating modes and reduces the excitation of transient oscillations, thereby improving overall system stability and robustness. Furthermore, this behavior indicates that the rotor position estimated by the proposed sensorless method is more closely aligned with the actual rotor position than that obtained using the conventional method. The Finite State Machine states associated with this transition are also presented in the third scheme of Figure 11. The numerical state values correspond to the following operating states: state 2 represents the Ramp Up stage, state 3 represents the Decreasing Iq stage, state 5 represents the PI initialization stage, and state 4 represents the Closed Loop FOC stage. Thus, the sequence observed in Figure 11, from states 2 → 3 → 5 → 4, represents the progression from the open-loop ramp-up operation, through I q   reduction, to PI initialization and finally to closed-loop FOC operation, as shown also in Figure 6. The open-loop-to-closed-loop transition occurs at approximately t=0.8 s.
The wide speed range capability of the proposed IWSSCF is evaluated in Figure 12, which presents the closed-loop responses of speed, torque and angle for the conventional and proposed startup methods, shown in (a) and (b), respectively, under identical I d step variations at nominal speed. During the initial interval, up to t = 1.5 s, the I d reference is maintained at zero. Nevertheless, for the proposed IWSSCF the torque feedforward term in the supplied angle remains active, thereby compensating for the angle error introduced by the sensorless flux observer and PLL in the conventional method. This improvement is reflected in the error-angle response, where the conventional method exhibits an angle error of approximately 0.25 rad, whereas the proposed technique maintains a lower value of approximately 0.17 rad. This indicates improved alignment between the estimated and actual d q   reference frames with the proposed method.
At t = 1.5 s, the I d reference is stepped from − 10 A up to -30A every 0.5 sec to evaluate field-weakening operation. Following this transition, the angle error decreases for both methods; however, a clear difference remains in their corresponding torque and speed responses. The application of negative I d changes the operating point and the orientation of the stator current vector, such that the remaining angular estimation error affects the d q -axis current decomposition and, consequently, the electromagnetic torque response. This effect is particularly evident in the conventional method, where the developed electromagnetic torque exhibits a larger deviation from its reference during field-weakening operation. The observed deviation indicates that the torque-producing current component is not maintained at the required level due to the remaining misalignment between the estimated and actual d q   reference frames. In contrast, the proposed method maintains improved d q -frame alignment and consequently achieves substantially better torque tracking, with the developed electromagnetic torque remaining considerably closer to its reference value. The improved torque regulation is also reflected in the speed response, where the proposed method exhibits more stable dynamic behavior during and after the field-weakening transition. Overall, the results demonstrate that the proposed sensorless method provides improved reference-frame alignment and torque control over the operating range considered. In particular, the lower angle error during normal operation and the improved torque tracking under field-weakening conditions indicate that the proposed method maintains a closer correspondence between the estimated and actual rotor reference frames, resulting in enhanced robustness and more accurate closed-loop operation.

4.2. Experimental Results of the Proposed IWSSCF

Following the simulation results presented in the previous section, the proposed model and control strategy were implemented on a real-time embedded system and experimentally evaluated using a motor dynamometer test bench. The experimental setup comprises a battery simulator NHR 9200, a motor drive FBLG2360T, a PMSM under test, with its characteristics tabulated in Table 1, and a second PMSM controlled by a four quadrant 400V back-to-back grid connected converter acting as the mechanical load. A power analyzer Zimmer LMG-671, together with dedicated voltage, current and torque measurement equipment, was used to monitor the electrical and mechanical quantities and assess the performance of the implemented control strategy.
The experimental evaluation was conducted under a set of operating conditions designed to assess the effectiveness of the proposed improvements and their impact on the system performance. First, open-loop operation was investigated under both no-load and loaded conditions, considering cases with and without the proposed improvements enabled during the startup. Subsequently, the torque-speed curve of the PMSM was experimentally evaluated for both cases, with and without field weakening enabled. The experimental results obtained are presented in the following sections in order to validate the proposed approach under real operating scenarios.
Figure 13. Experimental test bench consisting of a battery simulator, two PMSMs, motor drives, a torque meter and a power analyzer.
Figure 13. Experimental test bench consisting of a battery simulator, two PMSMs, motor drives, a torque meter and a power analyzer.
Preprints 241156 g013
The objective of the first test performed is to investigate the system’s behavior during startup, with and without the proposed open-loop techniques, that is loss minimization and angle compensator which are enabled during the startup process and the open-loop stage. The test is conducted under free shaft, where the PMSM under test is disconnected from the load. Figure 14 illustrates the experimental speed response during the startup of the PMSM in open-loop speed mode operation for both conventional and proposed IWSSCF. As observed with the conventional startup methodology, the motor successfully reaches the reference speed of 600 rpm; however, pronounced speed oscillations are evident during the initial startup transient. The oscillation amplitude increases progressively as the motor accelerates and becomes particularly noticeable within the intermediate speed range. As the motor approaches the reference speed, these oscillations gradually diminish, and the speed eventually settles around the commanded value. In contrast, when the proposed method is applied, a significant reduction in startup oscillations is observed, especially during the initial transient period. Although minor oscillatory behavior remains during acceleration, the speed response exhibits improved damping characteristics and converges more smoothly toward the reference speed, verifying the effectiveness of the developed EOAC technique. Once steady-state operation is reached, the motor speed remains closely regulated around the 600-rpm command. These results clearly demonstrate the effectiveness of the proposed optimization techniques in improving the transient startup performance of the drive system by reducing oscillations, enhancing damping, and facilitating smoother convergence to the desired operating speed.
The q-axis current responses during open-loop stage are presented in Figure 14. With the proposed IWSSCF, a reduction in the q-axis current can be observed throughout the acceleration process compared with the conventional startup method, verifying the effectiveness of the developed loss minimization algorithm. This reduction is particularly evident in the steady state region, where the current decreases from approximately 24 A to 12 A after reaching the target speed. However, a slightly increased current ripple can be observed at the proposed IWSSCF, attributed to the torque estimator regulating the current command. This behavior represents a trade-off between the reduction of the current magnitude and the increased ripple introduced during the optimized operation.
The startup response under a light mechanical load is shown in Figure 15. The experimental speed responses with and without the proposed optimization methods are compared against the reference trajectory. In both cases, the PMSM successfully reaches the commanded speed of 600 rpm. However, a clear difference can be observed in terms of speed fluctuations, where the proposed IWSSCF employing the EOAC technique exhibits significantly lower speed oscillations during startup around the reference speed after reaching the steady state operating region. These results demonstrate that the proposed IWSSCF improve the transient and steady state speed behavior of the PMSM under loaded operation, resulting in reduced oscillations and lower steady state speed ripple.
Next, the closed loop speed mode operating area is experimentally evaluated. The torque–speed characteristics were experimentally obtained for two different current levels, 40 Arms and 60 Arms. The measurements were performed with and without the field weakening controller enabled in order to evaluate the capability of the drive to maintain stable motor operation at high speed and under increased load conditions. Particular emphasis is placed on the operation in the vicinity of the rated speed, where the available voltage margin becomes limited and field weakening is required to extend the operating speed range. Figure 16a presents the torque vs speed curve at a current level of 40 Arms with and without the field weakening algorithm enabled. When field weakening is enabled, the motor maintains a higher torque level at high speeds, reaching approximately 4.5 Nm at 3000 rpm. In contrast, when the field weakening algorithm is disabled, the available torque decreases at high speeds, reaching approximately 4 Nm at 3000 rpm. This demonstrates the capability of the field weakening strategy to extend the high-speed operating region and maintain higher torque levels as the motor approaches the rated speed. Figure 16b and Figure 16c presents the q and d axis currents as a function of motor speed for both operating configurations. Without field weakening, the d axis current remains approximately zero throughout the operating range. When field weakening is enabled, the d axis current starts to decrease, i.e., becomes increasingly negative, as the motor speed approaches the voltage limit. The injection of negative d-axis current reduces the effective air-gap flux, thereby providing the required voltage margin for continued operation at higher speeds, according to Equation (2).
Figure 17 presents the experimental results obtained at a current level of 60 Arms. In both operating conditions, the available torque decreases as the motor speed increases, which is consistent with the voltage limitations encountered at higher speeds. However, when the proposed field-weakening algorithm is enabled, a substantially higher torque capability is maintained in the high-speed region, reaching approximately 4.9 Nm compared to 3.9 Nm when field weakening is disabled. Furthermore, the activation of the field-weakening strategy results in a significant reduction of the d-axis current as the motor speed increases, confirming the effective regulation of the machine flux under voltage-constrained operating conditions. The TVS characteristics obtained at both 40 Arms and 60 Arms current levels further validate the effectiveness of the proposed flux-weakening methodology. In both cases, the experimental results demonstrate a considerable extension of the achievable speed range while simultaneously preserving higher torque capability in the field-weakening region. These findings experimentally verify that the proposed flux-weakening approach can successfully extend the operating speed and load range of the drive system while maintaining robust performance of the sensorless control scheme.
Finally, a water-load test was conducted, representative of the considered motor-drive application, which exhibits a quadratic torque-speed relationship. Figure 18 presents the experimental comparison between the conventional and the proposed sensorless techniques during a water-load test performed at a speed slightly above the nominal operating speed and under a high-load condition. As the machine enters the field-weakening region and negative I d current is applied, the conventional method initially approaches the reference speed. However, despite the speed reaching a value close to its reference, the I q current continues to increase gradually until reaching the inverter current limit. This increase in I q is not consistent with the required steady-state operating condition. Since the applied water load is speed-dependent, the load torque becomes approximately constant once the machine speed has stabilized. Furthermore, as the speed approaches its reference and d ω / d t   approaches zero, the electromagnetic torque required from the machine should also reach a steady-state value. Therefore, a continued increase in the torque-producing I q current is not expected under these conditions. The simultaneous increase in I q and continued decrease in I d , despite the speed and load having reached an approximately steady state, indicates a progressive misalignment between the estimated and actual rotor d q reference frames. As the angular estimation error accumulates, the controller increasingly modifies the current components in an attempt to maintain the requested operating condition, resulting in excessive current demand and eventually driving the system toward instability. This behavior demonstrates the difficulty of maintaining accurate rotor-position estimation with the conventional method under high-load field-weakening operation.
In contrast, the proposed method exhibits a different response. Following the field-weakening transition and the subsequent acceleration to the steady-state operating point, both I d and I q converge to stable values without the continuous increase observed with the conventional method. The estimated rotor reference frame effectively remains locked to a consistent rotor position, allowing the current components to settle once the required electromagnetic torque and flux conditions are established. Consequently, the proposed method avoids the excessive current demand observed with the conventional PLL angle approach and maintains stable operation under the high-load field-weakening condition. These experimental results further demonstrate the improved robustness of the proposed sensorless method in maintaining d q -frame alignment and stable current regulation under demanding field-weakening high load operation.

5. Conclusions

This paper presented a sensorless PMSM control methodology addressing three key challenges encountered in wide-speed-range operation: startup efficiency, electromechanical oscillations during acceleration, and stable high-speed field-weakening operation. The proposed startup strategy adapts the torque-producing current according to the estimated mechanical power demand, preventing excessive current injection and reducing startup losses without compromising synchronization capability. In parallel, the proposed EOAC method mitigates the oscillatory behavior typically observed during open-loop acceleration and transition to closed-loop sensorless operation.
Both simulation and experimental results demonstrated the effectiveness of the proposed approach. During startup, the optimized methodology achieved approximately 50% lower steady-state current demand compared to the conventional approach at free shaft startup, while simultaneously reducing speed oscillations and providing a smoother acceleration profile. The effectiveness of the EOAC technique was further demonstrated by its ability to maintain stable acceleration and synchronization under increased load conditions, enabling successful startup in operating scenarios where the conventional approach exhibited pronounced oscillatory behavior and reduced robustness. To extend the operating range beyond base speed, a sensorless field-weakening strategy incorporating rotor-angle compensation was developed. Experimental evaluation verified stable operation in the field-weakening region and improved torque capability at high speed, achieving approximately 4.9 Nm compared to 3.9 Nm with the conventional implementation at 60 A. Furthermore, water-load tests representative of the target application confirmed robust sensorless operation under increasing load demand. Overall, the proposed methods provide an experimentally validated and robust solution for enhancing efficiency, dynamic performance, and wide-speed range operation in sensorless PMSM drives.

6. Patents

The patents resulting from the work reported in this manuscript are the following:
  • Sarigiannidis Athanasios et al., SYSTEM AND METHOD FOR COMPENSATING FOR ELECTROMECHANICAL OSCILLATION ANGLE IN A MOTOR DRIVE, US-2026/0230015-A1, United States Patent Application Publication, Aug. 6, 2026.
  • Karakasis Nektarios et al., SYSTEM AND METHOD FOR HIGH EFFICIENCYCLOSED-LOOP STARTUP FOR SENSORLESS MOTOR DRIVE, US-2025/0357878-A1, United States Patent Application Publication, Nov. 20, 2025.

Author Contributions

Conceptualization, A.S. and Ne.K.; methodology, A.S., Ne.K and Ni.K.; software, Ni.K., Ne.K. and A.S.; validation, J.L. and Ni.K.; writing—original draft preparation, A.S., Ni.K and J.L.; writing—review and editing, A.S, Ne.K., N.T.; project administration, N.T. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Data Availability Statement

Not applicable.

Conflicts of Interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

References

  1. Bose, B. K. Power Electronics and Motor Drives: Recent Progress and Perspective. IEEE Trans. Ind. Electron. 2009, 56(2), 581–588. [Google Scholar] [CrossRef]
  2. Vlachou, V.I.; Sakkas, G.K.; Xintaropoulos, F.P.; Pechlivanidou, M.S.C.; Kefalas, T.D.; Tsili, M.A.; Kladas, A.G. Overview on Permanent Magnet Motor Trends and Developments. Energies 2024, 17, 538. [Google Scholar] [CrossRef]
  3. Rafaq, M. S.; Jung, J.-W. A Comprehensive Review of State-of-the-Art Parameter Estimation Techniques for Permanent Magnet Synchronous Motors in Wide Speed Range. IEEE Trans. Ind. Inform. 2020, 16(7), 4747–4758. [Google Scholar] [CrossRef]
  4. Pillay, P.; Krishnan, R. Modeling, simulation, and analysis of permanent-magnet motor drives. II. The brushless DC motor drive. IEEE Trans. Ind. Appl. 1989, 25(2), 274–279. [Google Scholar] [CrossRef]
  5. Elkholy, M.M.; Algendy, M.M.; El-Hay, E.A. Modern Control Techniques and Operational Challenges in Permanent Magnet Synchronous Motors: A Comprehensive Review. Automation 2025, 6, 49. [Google Scholar] [CrossRef]
  6. Busarello, T. D. C.; Bubshait, A.; Varaprasad, O. V. S. R.; Alsaleem, A.; Simões, M. G. A Comprehensive Methodology of Field-Oriented Control Design With Parameter Variation Analysis for Interior Permanent Magnet Synchronous Machine Drives. IEEE Access 2025, 13, 89524–89541. [Google Scholar] [CrossRef]
  7. Morimoto, S.; Sanada, M.; Takeda, Y. Wide-speed operation of interior permanent magnet synchronous motors with high-performance current regulator. IEEE Trans. Ind. Appl. 1994, 30(4), 920–926. [Google Scholar] [CrossRef]
  8. Ghanayem, H.; Alathamneh, M.; Nelms, R.M. Decoupled Speed and Flux Control of Three-Phase PMSM Based on the Proportional-Resonant Control Method. Energies 2023, 16, 1053. [Google Scholar] [CrossRef]
  9. Wang, G.; Valla, M.I.; Solsona, J.A. Position Sensorless Permanent Magnet Synchronous Machine Drives: A Review. IEEE Trans. Ind. Electron. 2020, 67(7), 5830–5842. [Google Scholar] [CrossRef]
  10. He, W.; Wu, X.; Chen, J.; Wang, Y. Comparative study of sensorless control of Permanent magnet synchronous motor realised by sliding-mode observer. IET Power Electron. 2020, 13, 1191–1199. [Google Scholar] [CrossRef]
  11. Zhang, K.; et al. Nonlinear Flux Observer for Sensorless Control of IPMSM Based on a Novel Regression Model. IEEE Trans. Power Electron. 2025, 40(3), 3916–3926. [Google Scholar] [CrossRef]
  12. Wang, G.; Yang, L.; Yuan, B.; Wang, B.; Xu, D. Pseudo-Random High-Frequency Square-Wave Voltage Injection Based Sensorless Control of IPMSM Drives for Audible Noise Reduction. IEEE Trans. Ind. Electron. 2016, 63(12), 7413–7423. [Google Scholar] [CrossRef]
  13. Sun, J.; Zhao, J.; Tian, L.; Song, Y.; Liu, Y. Bandwidth and Audible Noise Improvement of Sensorless IPMSM Drives Based on Amplitude-Modulation Multi-Random Frequency Injection. IEEE Trans. Power Electron. 2022, 37(12), 14126–14140. [Google Scholar] [CrossRef]
  14. Wu, T.; Zhu, H.; Wu, X.; Huang, S.; Yu, X.; Tan, Z.; Gao, F.; Tong, X. Enhanced Sequential High-Frequency Voltage Injection Method for Low-Speed Sensorless Control of IPMSM. IEEE Trans. Power Electron. 2025, 40(8), 10836–10845. [Google Scholar] [CrossRef]
  15. Pan, A.; Su, M.; Lin, J.; et al. Adaptive Back-EMF Observer Based on Filtered Transformation for Sensorless SPMSM Control. IEEE Trans. Power Electron. 2025, 40(11), 16231–16242. [Google Scholar] [CrossRef]
  16. Xu, A.-F.; Zhu, X.; Yuan, L. Hybrid Model Flux Observer for PMSM Sensorless Control System Considering Parameter Disturbances and Measurement Noise. IEEE Access 2025, 13, 33049–33061. [Google Scholar] [CrossRef]
  17. Kivanc, O. C.; Ozturk, S. B. Sensorless PMSM Drive Based on Stator Feedforward Voltage Estimation Improved With MRAS Multiparameter Estimation. IEEE/ASME Trans. Mechatron. 2018, 23(3), 1326–1337. [Google Scholar] [CrossRef]
  18. Zhang, L.; Tao, R.; Bai, J.; Zeng, D. An Improved Sliding-Mode Model Reference Adaptive System Observer for PMSM Applications. Expert Syst. With Appl. 2024, 250, 123907. [Google Scholar] [CrossRef]
  19. Gopinath, G. R.; Das, S. P. An Extended Kalman Filter based Sensorless Permanent Magnet Synchronous Motor Drive with Improved Dynamic Performance. Proceedings of IEEE International Conference on Power Electronics, Drives and Energy Systems (PEDES), Chennai, India, 18-21 December 2018. [Google Scholar] [CrossRef]
  20. He, W.; Wu, X.; Chen, J.; Wang, Y. Comparative Study of Sensorless Control of Permanent Magnet Synchronous Motor Realised by Sliding-Mode Observer. IET Power Electron. 2020, 13(6), 1191–1199. [Google Scholar] [CrossRef]
  21. Xing, J.; Qin, Z.; Lin, C.; Jiang, X. Research on Startup Process for Sensorless Control of PMSMs Based on I-F Method Combined with an Adaptive Compensator. IEEE Access 2020, 8, 70812–70821. [Google Scholar] [CrossRef]
  22. Chen, D.; Lu, K.; Wang, D. An I-f Startup Method with Compensation Loops for PMSM with Smooth Transition. IEEJ J. Ind. Appl. 2020, 9(3), 263–270. [Google Scholar] [CrossRef]
  23. Nair, S. V.; Hatua, K.; Prasad, N. V. P. R.; Reddy, D. K. Quick and Seamless Transition Method for I-f to Sensorless Vector Control Changeover and On-the-Fly Start of PMSM Drives. IET Electr. Power Appl. 2020, 14, 2231–2242. [Google Scholar] [CrossRef]
  24. Chen, B.; Shen, A.; Li, P.; Luo, X.; Xu, S.; Xu, J. Restart Strategy for Sensorless PMSM Drive System Based on Zero-Voltage Vector. IET Electr. Power Appl. 2020, 14, 2362–2369. [Google Scholar] [CrossRef]
  25. Wang, J.; Ma, J.; Zhao, X.; Meng, D.; Xu, K.; Guo, D. Sensorless Control Strategy for Interior Permanent Magnet Synchronous Motors in the Full-Speed Section. Energies 2023, 16, 7701. [Google Scholar] [CrossRef]
  26. Ning, B.; Zhao, Y.; Cheng, S. An Improved Sensorless Hybrid Control Method of Permanent Magnet Synchronous Motor Based on I/F Startup. Sensors 2023, 23, 635. [Google Scholar] [CrossRef] [PubMed]
  27. Wang, L.; Yu, Y.; Wang, B.; Xu, D. Bandwidth-Based Tuning Method for PMSM Field-Weakening Control With Speed Adaptation. IEEE Trans. Ind. Electron. 2025, 72(11), 10986–10997. [Google Scholar] [CrossRef]
  28. Zhang, W.; Zhai, Y.; Zhu, P.; Xu, Y.; Zou, J.; Vazquez, S. Power Regulated Field-Weakening Control Strategy with Adaptive Observers for Permanent Magnet Synchronous Motors. IEEE Trans. Transp. Electrif. in press. [Google Scholar] [CrossRef]
  29. Carpaneto, M.; Marchesoni, M.; Parodi, G. A sensorless PMSM drive operating in the field weakening region using only one current sensor. Proceedings of IEEE International Symposium on Industrial Electronics, Bari, Italy, 4-7 July 2010. [Google Scholar] [CrossRef]
  30. Yoo, J.; Lee, J.; Sul, S. -K. Analysis of Instability in Torque Control of Sensorless PMSM Drives in Flux Weakening Region. IEEE Trans. Power Electron. 2021, 36(9), 10815–10826. [Google Scholar] [CrossRef]
  31. Karakasis, N.; Sarigiannidis, A.; Tsakalakis, N.; Bartz, S. High Efficiency Closed-Loop Startup Strategy for Sensorless Permanent Magnet Motor Drive. Proceedings of International Conference on Electrical Machines (ICEM), Torino, Italy, 01-04 September 2024. [Google Scholar] [CrossRef]
  32. Sarigiannidis, A.; Kampouroglou, N.; Karakasis, N.; Tsakalakis, N. Electromechanical Oscillations Angle Compensation Technique for Sensorless Permanent Magnet Motor Drive. Proceedings of IEEE Workshop on Electrical Machines Design, Control and Diagnosis (WEMDCD), Valletta, Malta, 09-10 April 2025. [Google Scholar] [CrossRef]
  33. Sarigiannidis, A. G.; Kladas, A. G. Switching Frequency Impact on Permanent Magnet Motors Drive System for Electric Actuation Applications. IEEE Trans. Magn. 2015, 51(3), 8202204. [Google Scholar] [CrossRef]
  34. Szabat, K.; Orlowska-Kowalska, T. Vibration Suppression in a Two-Mass Drive System Using PI Speed Controller and Additional Feedbacks. IEEE Trans. Ind. Electron. 2007, 54(2), 1193–1206. [Google Scholar] [CrossRef]
  35. Liu, S.; Ma, Z.; Jin, Y. Hybrid Sensorless Control Phase-Locked Loop Transition Strategy for PMSM Drives. Proceedings of IEEE 9th International Power Electronics and Motion Control Conference (IPEMC2020-ECCE Asia), Nanjing, China, 29 November - 02 December 2020. [Google Scholar] [CrossRef]
Figure 1. PMSM manufacturer’s torque-speed curve for continuous and overload operation.
Figure 1. PMSM manufacturer’s torque-speed curve for continuous and overload operation.
Preprints 241156 g001
Figure 2. Block diagram of the proposed IWSSCF.
Figure 2. Block diagram of the proposed IWSSCF.
Preprints 241156 g002
Figure 3. Phasor representation of the d q and d ′ q ′ reference frames during open-loop startup.
Figure 3. Phasor representation of the d q and d ′ q ′ reference frames during open-loop startup.
Preprints 241156 g003
Figure 4. Block diagram of the proposed low speed range loss minimization algorithm.
Figure 4. Block diagram of the proposed low speed range loss minimization algorithm.
Preprints 241156 g004
Figure 5. Block diagram of the proposed EOAC technique.
Figure 5. Block diagram of the proposed EOAC technique.
Preprints 241156 g005
Figure 6. Sequence of the proposed sensorless startup and transition to closed-loop speed operation.
Figure 6. Sequence of the proposed sensorless startup and transition to closed-loop speed operation.
Preprints 241156 g006
Figure 7. Block diagram of the sensorless speed and angle PLL estimator.
Figure 7. Block diagram of the sensorless speed and angle PLL estimator.
Preprints 241156 g007
Figure 8. Block diagram of the speed and field weakening controllers.
Figure 8. Block diagram of the speed and field weakening controllers.
Preprints 241156 g008
Figure 9. Speed, Iq and angle error for open loop startup performance tests for both conventional and proposed methods. (a) startup failure of the conventional method test (b) successful startup of both methods test.
Figure 9. Speed, Iq and angle error for open loop startup performance tests for both conventional and proposed methods. (a) startup failure of the conventional method test (b) successful startup of both methods test.
Preprints 241156 g009
Figure 10. Conventional versus proposed method speed, Iq and AC power for Open Loop Operation Under Torque Load Transitions Test.
Figure 10. Conventional versus proposed method speed, Iq and AC power for Open Loop Operation Under Torque Load Transitions Test.
Preprints 241156 g010
Figure 11. Conventional versus proposed method speed, Iq and AC power for Transition from Open Loop to Closed Loop Test.
Figure 11. Conventional versus proposed method speed, Iq and AC power for Transition from Open Loop to Closed Loop Test.
Preprints 241156 g011
Figure 12. (a) Conventional versus (b) proposed method speed, Torque, Id and angle error for Closed Loop Operation under   I d   Variations Test.
Figure 12. (a) Conventional versus (b) proposed method speed, Torque, Id and angle error for Closed Loop Operation under   I d   Variations Test.
Preprints 241156 g012
Figure 14. Conventional versus proposed method speed (top) and q axis (bottom) current for open loop startup performance test without load.
Figure 14. Conventional versus proposed method speed (top) and q axis (bottom) current for open loop startup performance test without load.
Preprints 241156 g014
Figure 15. Speed Response during startup under load: comparison results with and without the proposed methods.
Figure 15. Speed Response during startup under load: comparison results with and without the proposed methods.
Preprints 241156 g015
Figure 16. Torque versus Speed test at 40Arms with and without field weakening control. (a) Torque vs Speed (b) Iq vs Speed (c) Id vs Speed.
Figure 16. Torque versus Speed test at 40Arms with and without field weakening control. (a) Torque vs Speed (b) Iq vs Speed (c) Id vs Speed.
Preprints 241156 g016
Figure 17. Torque versus Speed test at 60Arms with and without Field Weakening: (a) Torque vs Speed (b) Iq vs Speed (c) Id vs Speed.
Figure 17. Torque versus Speed test at 60Arms with and without Field Weakening: (a) Torque vs Speed (b) Iq vs Speed (c) Id vs Speed.
Preprints 241156 g017
Figure 18. Conventional versus proposed methodology speed, Iq and Id for Water Load Test in the Field Weakening Region.
Figure 18. Conventional versus proposed methodology speed, Iq and Id for Water Load Test in the Field Weakening Region.
Preprints 241156 g018
Table 1. Sensorless Motor Drive Specifications.
Table 1. Sensorless Motor Drive Specifications.
Quantity Value
Rated rms Current, I (A) 21.6
Rated Speed, n (rpm) 3000
Torque Constant, Kt (Nm/Arms) 0.14
Voltage Constant, Ke (V/krpm) 8.5
Pole pairs, p 5
Number of slots 12
D axis inductance, Ld (mH) 0.215
Q axis inductance, Lq (mH) 0.215
Stator resistance, Rs (mOhm) 0.04
Input DC battery voltage, Vdc (V) 48
PWM frequency, fc (kHz) 16
Rotor Position Estimator frequency, fa (kHz) 16
Speed observer frequency, fobv (kHz) 16
Current Controller frequency, fcc (kHz) 16
Speed Controller frequency, fsc (kHz) 1
Field Weakening Controller frequency, ffw (kHz) 1
Open-Loop Torque estimation frequency, ft (kHz) 1
Open loop EOAC update frequency, fac (kHz) 1
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.
Copyright: This open access article is published under a Creative Commons CC BY 4.0 license, which permit the free download, distribution, and reuse, provided that the author and preprint are cited in any reuse.