Preprint
Article

This version is not peer-reviewed.

Uncertainty-Aware Adaptive Control of Metro-Induced Environmental Vibration Under Unknown Excitation

Submitted:

28 October 2026

Posted:

29 October 2026

You are already at the latest version

Abstract
Metro-induced environmental vibrations impair the serviceability of adjacent vibra-tion-sensitive buildings and their durability through long-term accumulation, posing a challenge to the sustainable use of existing buildings. Due to uncertainty in the struc-tural model and an unknown, non-stationary vibration source, structural vibration control remains challenging. To address these problems, this paper proposes an uncer-tainty-aware method that combines system identification by a generalized extended Kalman filter with unknown input and the linear-quadratic-Gaussian (LQG) active control, for buildings under metro-induced excitation. First, the time-varying structur-al parameters are augmented into the state vector and identified with the state and the base excitation, the latter being recovered under an adaptive weight driven by the posterior covariance to suppress noise amplification. The identified state is then fed back, while the parameters enter the gain synthesis in proportion to their posterior confidence, to keep the control force smooth and maintain the control performance under uncertain parameter estimates. Finally, the noise covariances and the regulator weighting matrices are fixed by a two-stage salp swarm search, thereby improving the identification accuracy and the control performance. The proposed method is exam-ined on a nine-story frame structure under unknown metro excitation, with model mismatch and measurement noise, to verify its effectiveness.
Keywords: 
;  ;  ;  ;  ;  ;  

1. Introduction

The expansion of urban rail transit has brought a growing number of buildings into the immediate vicinity of metro lines. Trains running in tunnels radiate ground-borne waves into the adjacent structures [1,2], producing foundation accelerations of the order of milli-g [3,4]. Modest as it is, such excitation acts throughout the service life of the building: it degrades the serviceability of vibration-sensitive buildings such as precision laboratories, hospitals and residences [5], and its accumulation is a recognized concern for durability [6]. Controlling it is therefore essential to the sustainable use of buildings along metro lines.
A variety of passive strategies has been developed for vibration control [7,8], including base isolation [9], tuned mass and tuned viscous mass dampers [10,11] and inerter-based absorbers [12,13]. However, the excitation varies with train speed, axle load and track condition, while the structure is subject to modeling error and its properties change during service, so that a device tuned to the nominal configuration becomes detuned. Active and semi-active control, in which the force is computed online by optimal algorithms such as the linear quadratic regulator (LQR) and its linear-quadratic-Gaussian (LQG) extension [14], can overcome this limitation, but it must be integrated with the identification of the structural state in real time.
Numerous studies have accordingly been conducted on the identification of structural systems from measured responses [15,16,17,18] and on its integration with vibration control in real time. Xu and Chen [19,20] combined semi-active friction dampers with health monitoring, Lei et al. integrated decentralized control with unknown-input identification [21] and with online damage detection [22], He et al. [23] derived the control law from a structure identified under unknown ground excitation, and Su et al. [24] treated an ATMD–structure coupling system under unknown wind loads. Schemes of this kind rest on an estimator whose formulation depends on how the unknown input enters the observation equation. Pan et al. [25] removed the requirement that its coefficient matrix be of full column rank, and Lei et al. [26] dispensed with collocated acceleration measurements by data fusion. Under base excitation, however, the measured absolute accelerations carry no feedthrough term, and the current excitation cannot be recovered by these formulations. Lei et al. [27] proposed a generalized extended Kalman filter with unknown input (GEKF-UI), and integrated the structural identification with vibration control. The formulation has since been extended to the identification of earthquake input [28] and to the unscented Kalman filter [29].
These formulations have been developed largely under seismic and wind excitation, whereas metro-induced environmental vibration is a weak, non-stationary random process with a low signal-to-noise ratio. Recovery of the excitation from such a response is ill-posed. Jacquelin et al. [30] analysed force reconstruction as a deconvolution whose least-squares solution amplifies the measurement noise without bound and must therefore be regularized, the regularization parameter being chosen in advance from a global criterion such as the L-curve [31]. In the filter formulations the same quantity appears as the process-noise covariance of the unknown input, which is likewise assigned by the user [32,33]. Vettori et al. [34] showed that it need not be held constant and adjusted it online. Because the conditioning of the inversion follows the current response, a weight fixed once is either too loose to suppress the noise or too tight to follow the excitation. The weight must instead be revised at each step from the reliability of the current estimate.
In addition to the challenges above, the structural model from which the gain is computed is known only approximately, differing from the actual building at the outset and changing further during service. Its error therefore passes directly into the control law. Yuen et al. [35] met this by a clipped robust reliability-based control, the uncertainty being described by a probability model assigned before the run, and Xu et al. [36] absorbed it into the robustness of an adaptive sliding-mode law. In the integration schemes of He et al. [23] and Lei et al. [27], by contrast, the parameters identified at each step are substituted into the gain as they stand, in accordance with certainty equivalence [37]. The robust designs forgo the information that the identification accumulates as the record proceeds, whereas the certainty-equivalent designs exploit that information but credit it in full at every step. Their validity rests on the rate at which the parameters are determined, and under weak excitation that rate is low: the measurements inform them only in proportion to the response they produce, the attainable precision being bounded below accordingly [38], and the damping least well determined of all [39]. The identified parameters accordingly carry an uncertainty of their own, which the estimator itself quantifies but which takes no part in the design of the gain. It is therefore necessary to carry this uncertainty into the control design.
Both the estimator and the controller contain quantities that must be fixed before either can run and that neither the structure nor the measurements determine. The process and measurement noise covariances of the filter have been estimated from data by subspace methods [40] and tuned by Bayesian optimization [41]. The weighting matrices of the performance index, whose selection usually requires considerable experimentation, have been determined automatically [42] and by search, using particle swarm optimization [43], genetic algorithms [44] and the salp swarm algorithm [45,46]. Searches of this kind are effective but need many evaluations of the objective, which becomes prohibitive when each candidate is assessed by closed-loop simulation; they are therefore increasingly combined with Gaussian-process surrogates [47], whose predictive variance indicates where a further evaluation is most informative [48,49].
This paper proposes an integrated identification and control method for buildings under unknown metro-induced excitation, in which the uncertainty of the identification is quantified and carried into the control design. The structural parameters are augmented into the state vector, and the excitation, the state and the parameters are identified by a GEKF-UI from a sparse set of fused acceleration and drift measurements. The inversion for the excitation is regularized by a weight taken from the posterior variance of the input estimate, which the filter already propagates, so that the regularization relaxes while the estimate is uncertain and tightens as it is determined. A confidence weight formed from the posterior covariance of the parameters blends the nominal and the identified parameters in the model entering the gain synthesis, so that the design rests on the nominal model while the identification is uninformative and follows the identified one as it becomes reliable. The noise covariances of the estimator and the weighting matrices of the regulator are determined offline by a surrogate-assisted salp swarm search, the estimator first and the controller on the estimates it produces. The method is examined on the nine-story SAC benchmark building under a measured metro base-acceleration record, over eighteen cases of model mismatch, time variation and measurement noise.
The remainder of the paper is organized as follows. Section 2 presents the joint identification of the unknown excitation, the structural state and the structural parameters. Section 3 synthesizes the adaptive LQG control with the online identification and describes the two-stage offline tuning. Section 4 presents the numerical model, the uncertainty cases and the design optimization, and examines the identification and control performance. Conclusions are given in Section 5.

2. Structural Identification under Unknown Base Excitation

The building is modeled as an n-story shear structure in the horizontal direction. Let q t , q ˙ t , q ¨ ( t ) denote the floor displacement, velocity, and acceleration vectors relative to the moving base. The motion equation of a controlled n-DOF structure under unknown excitations can be expressed as
M q ¨ ( t ) + C q ˙ ( t ) + Kq ( t ) = η u u ( t ) + η s s ( t )  
where, M,C and K denote the mass, damping and stiffness of the controlled structure, respectively. u(t) and s(t) denote the control force and the unknown external excitation; ηu and ηs are their localization matrix, respectively.
The identification is performed recursively on the basis of the extended Kalman filter. The state and observation equations are established in Section 2.1. At each time step, the augmented state is first predicted (Section 2.2), the unknown excitation is then identified from the innovation of the prediction (Section 2.3), and the augmented state is finally updated with the remaining innovation (Section 2.4).

2.1. The State and Observation Equations

In this paper, the mass of controlled structure is assumed to be known. To account for modeling uncertainty caused by discrepancies between the actual and nominal structural models, the structural parameters are augmented into the state vector. The extended state vector is defined as Z = [ q t T , q ˙ t T , θ ( t ) T ] T , where θ is a vector of structural damping and stiffness parameters.
The structural parameters may vary during service in a manner not known in advance, and their evolution is modeled as a random walk driven by a process noise:
θk+1 = θk + ωθ,k
where, ωθ is a zero-mean Gaussian white noise with covariance Qθ.
Then the state-space representation of Equation (1) can be given by
Z ˙ = q ˙ M − 1 [ − C q ˙ − Kq + η u u + η s s ] 0 = g ( Z ) + B u u + B s s
where,
g ( Z ) = q ˙ − M − 1 [ C q ˙ + Kq ] 0 ,   B u = 0 M − 1 η u 0 ,   B s = 0 M − 1 η s 0
The continuous nonlinear state transition function is linearized about the current posterior estimate Z k = Z ^ k | k as
Z ˙ = G k | k Z + B u u + B s s + b k ,   b k = g Z ^ k | k − G k | k Z ^ k | k
where, the Jacobian matrix Gk|k is defined as
G k | k = ∂ g ∂ Z Z k = Z ^ k | k = 0 − M − 1 K ( θ ^ k | k ) 0 I − M − 1 C ( θ ^ k | k ) 0 0 G θ , k 0
G θ , k ∈ R n × n θ represents the sensitivity matrix of the dynamic equation to the structure parameter θ , with its ith column given by
G θ , k ( i ) = − M − 1 ∂ C ∂ θ i q ˙ ^ k | k + ∂ K ∂ θ i q ^ k | k
To prevent the low-frequency drift caused by the insensitivity of accelerometers to quasi-static components [26], the measurement vector y ( t ) ∈ R n y is formed by fusing inter-story displacement and acceleration responses, and the observation equation is
y k + 1 = y a , k + 1 y d , k + 1 = L a a k + 1 + υ a , k + 1 L d T d q k + 1 + υ d , k + 1 = h ( Z k + 1 ) + D u u k + 1 + D s s k + 1 + υ k + 1
where,
h ( Z ) = − L a M − 1 [ C q ˙ + Kq ] L d T d q , D u = L a M − 1 η u 0 , D s = L a ( M − 1 η s + r ) 0 = 0
La and Ld denote sensor placement matrix of limited acceleration and inter-story displacement, respectively; Td denote the transform matrix between inter-story displacement and displacement; υa,k+1 and υd,k+1 are the measurement noises with covariance matrix R = blkdiag(Ra,Rd).
The state equation, Equation (3) is written in relative coordinates, whereas the accelerometers measure the absolute response, a k + 1 = q ¨ k + 1 + r a s , k + 1 , with r ∈ ℝn the influence vector mapping the base motion to each degree of freedom. For base excitation the location matrix satisfies ηs = −Mr, so that
M−1ηs + r = 0
and the base acceleration cancels from the observation equation. The feedthrough matrix of the unknown excitation therefore vanishes, Ds = 0, and the system has no direct feedthrough.
Similarly, the nonlinear observation equation is locally linearized around the predicted prior state Z ¯ k + 1 | k as
y k + 1 = H k + 1 | k Z k + 1 + D u u k + 1 + h ¯ k + 1 | k + υ k + 1
where ,   h ¯ k + 1 | k = h ( Z ¯ k + 1 | k ) − H k + 1 | k Z ¯ k + 1 | k
H k + 1 | k = ∂ h ∂ Z Z k = Z ¯ k + 1 | k = H x , k + 1 | k H θ , k + 1 | k = − L a M − 1 K − L a M − 1 C L a G θ L d T d 0 0
with K,C and Gθ evaluated at Z ¯ k + 1 | k .
Unlike current EKF-UI approaches that require the unknown input to appear explicitly in the observation equation [17], the metro-induced vibration considered here has no direct feedthrough, and the current excitation can be identified only through its effect on the augmented state. The state equation is therefore discretized in such a way that the excitation at tk+1 enters the augmented state at the same instant.

2.2. Time Update of the Augmented State

In the existing EKF-UI approaches, the unknown excitation is discretized with a zero-order hold, i.e., it is assumed constant within a sampling interval [33]. The current excitation sk+1 then does not enter Zk+1 and, with Ds = 0, can be identified only with a one-step delay. Therefore, a first-order hold [28] is adopted, in which the excitation varies linearly within the sampling interval ∆t,
s ( t k + τ ) = ( 1 − τ ∆ t ) s k + τ ∆ t s k + 1 ,   0 ≤ τ ≤ ∆ t
where, ∆t = tk+1 − tk is the sampling interval.
Integrating Equation (4) yields the discrete recursive equation for the augmented state:
Z k + 1 = A k Z k + B k u u k + B k s , − s k + B k s , + s k + 1 + c k + ω k
where, A k = e G k | k ∆ t , [ B k u , B k s , − , B k s , + , c k ] = ∫ 0 ∆ t e G k | k ( ∆ t − τ ) [ B u , B s ( 1 − τ ∆ t ) , B s τ ∆ t , b k ] d τ ; and ωk is the process noise, which is a zero-mean Gaussian white noise with covariance matrix Qk = blkdiag(Qx,Qθ).
As sk+1 is not yet known, the prior estimate of the augmented state is obtained from Equation (10) without the current excitation:
Z ¯ k + 1 | k = A k Z ^ k | k + B k u u k + B k s , − s ^ k | k + c k
and its error covariance, which includes the error of s ^ k | k , and its correlation with the state error, is
P ¯ k + 1 | k = A k B k s , − P ^ k | k P Zs , k | k P sZ , k | k P s , k | k A k T ( B k s , − ) T + Q k
where Ps,k|k is the error variance of s ^ k | k , and P Zs , k | k = P sZ , k | k T is the cross-covariance between the errors of Z ^ k | k and s ^ k | k .

2.3. Regularized Estimation of Unknown Excitation

With the predicted measurement y ¯ k + 1 | k = h ( Z ¯ k + 1 | k ) + D u u k + 1 , the innovation is defined as e k + 1 = y k + 1 − y ¯ k + 1 | k . Substituting Equations (10) and (11) into Equation (8) yields
e k + 1 = J k + 1 s k + 1 + ε k + 1 ,   J k + 1 = H k + 1 | k B k s , +
where Jk+1 is the equivalent input sensitivity matrix and εk+1, which comprises the prediction error and the measurement noise, has the covariance R e , k + 1 = H k + 1 | k P ¯ k + 1 | k H k + 1 | k T + R .
Equation (13) is an inverse problem for sk+1. When the excitation is observable from the sensors, Jk+1 has full column rank; it is, however, severely ill-conditioned, since the low-pass behavior of the structure causes its singular values to decay rapidly. The least-squares solution of Equation (13) therefore amplifies the measurement noise into non-physical high-frequency oscillations, increasingly so as the signal-to-noise ratio decreases.
To regularize the inversion, the excitation is modeled as a random walk, sk+1 = sk + ωs,k with ωs,k~N(0,Qs), which constrains only its continuity between adjacent samples. The prior mean and variance of sk+1 are then s ¯ k + 1 | k = s ^ k | k and Ps,k+1|k = Ps,k|k + qs, and combining this prior with Equation (13) gives the regularized estimate:
s ^ k + 1 | k + 1 = argmin s ( e k + 1 − J k + 1 s ) T R e , k + 1 − 1 ( e k + 1 − J k + 1 s ) + λ s , k + 1 s − s ¯ k + 1 | k 2 ,   λ s , k + 1 = 1 P s , k | k + q s
where the regularization weight λs,k+1 is the inverse of the prior variance. It decreases when the previous estimate is uncertain, placing more weight on the current measurement.
The solution of Equation (14) and its error variance are
s ^ k + 1 | k + 1 = P s , k + 1 | k + 1 J k + 1 T R e , k + 1 − 1 e k + 1 + λ s , k + 1 s ¯ k + 1 | k ,   P s , k + 1 | k + 1 = ( J k + 1 T R e , k + 1 − 1 J k + 1 + λ s , k + 1 I ) − 1
In implementation, Equation (14) is solved by QR factorization of the stacked weighted system instead of the normal equations, which avoids squaring the condition number.
The identified excitation is then compensated into the prior estimate and its covariance:
Z ¯ k + 1 | k * = Z ¯ k + 1 | k + B k s , + s ^ k + 1 | k + 1
P ¯ k + 1 | k * = P ¯ k + 1 | k + B k s , + P s , k + 1 ( B k s , + ) T + P Zs , k + 1 ( B k s , + ) T + B k s , + P Zs , k + 1 T
where P Zs , k + 1 = − P ¯ k + 1 | k H k + 1 | k T ( P s , k + 1 J k + 1 T R e , k + 1 − 1 ) T is the cross covariance between the errors of Z ¯ k + 1 | k and s ^ k + 1 | k + 1 .
Finally, the contribution of the identified excitation is removed from the innovation,
e r , k + 1 = e k + 1 − J k + 1 s ^ k + 1 | k + 1
The remaining innovation er,k+1 is used to update the augmented state in Section 2.4. The excitation at tk+1 is thus identified from the measurement without delay.

2.4. Estimation of Structural State

After the compensation, the measurement residual with respect to Z ¯ k + 1 | k * equals the remaining innovation er,k+1, and the augmented state is updated as in the conventional extended Kalman filter:
S r , k + 1 = H k + 1 | k P ¯ k + 1 | k * H k + 1 | k T + R ,   K k + 1 KF = P ¯ k + 1 | k * H k + 1 | k T S r , k + 1 − 1
Z ^ k + 1 | k + 1 = Z ¯ k + 1 | k * + K k + 1 KF e r , k + 1
where KKF distinguishes the Kalman gain from the stiffness matrix. Equation (20) provides the estimates of the structural state and parameters at tk+1.
The error covariance and the cross covariance between the state and input errors are updated in the Joseph-stabilized form:
P ^ k + 1 | k + 1 = ( I − K k + 1 KF H k + 1 | k ) P ¯ k + 1 | k * ( I − K k + 1 KF H k + 1 | k ) T + K k + 1 KF R k + 1 ( K k + 1 KF ) T
P Zs , k + 1 | k + 1 = ( I − K k + 1 KF H k + 1 | k ) P Zs , k + 1 + K k + 1 KF R k + 1 ( P s , k + 1 J k + 1 T R e , k + 1 − 1 ) T
The complete procedure is summarized in Figure 1.

3. Synthesis of Adaptive LQG Control with the Online Estimation

The estimator of Section 2 provides, at each time step, the state and parameter estimates together with their error covariance. These are synthesized here with LQG control: the control model is reconstructed from the identified parameters and the gain is re-synthesized accordingly, which constitutes an indirect self-tuning regulator [27]. The identified parameters are, however, weighted by their posterior confidence before entering the gain synthesis, so that the gain follows the identification only as far as the identification is reliable. The overall framework is shown in Figure 2.

3.1. Confidence-Weighted Adaptive Control Model

The control acts on the structural state x = q T , q ˙ T T , whose estimate x ^ k + 1 | k + 1 consists of the first 2n components of Z ^ k + 1 | k + 1 in Equation (20). In the existing synthesis approaches, the identified parameters are used directly in the gain synthesis [23,27], i.e., the principle of certainty equivalence is adopted.
Certainty equivalence holds only when the parameter error is small enough to be neglected in the gain, a condition not met under weak excitation. The measurements inform the parameter block of the extended state only through the sensitivity Gθ of Equation (5), which is proportional to the structural response and is therefore small, so that the parameter block of Pk+1|k+1 decays slowly. The parameter estimation error must accordingly be taken into account in the gain synthesis [36].
That uncertainty is already quantified in the posterior covariance, and a confidence weight is formed from it,
γ k + 1 = e − tr P θ , k + 1 | k + 1 n θ τ P
where τP is a confidence scale and nθ is the number of identified parameters, the trace being normalized so that the exponent is the mean posterior variance per parameter.
The parameters used in the gain synthesis are
θ c , k + 1 = 1 − γ k + 1 θ 0 + γ k + 1 θ ^ k + 1 | k + 1
which approach the identified parameters as the posterior covariance decreases, and remain close to the nominal model θ0 while it is large.
Equation (24) is applied only after the confidence weight has first risen above a prescribed threshold, the gain being held at its nominal value until then.
With θc the controlled structure is described in relative coordinates by the continuous state-space model
x ˙ = A c ( θ c ) x + B c u u + B c s s
where,
A c ( θ c ) = 0 I − M − 1 K ( θ c ) − M − 1 C ( θ c ) , B c u = 0 M − 1 η u , B c s = 0 M − 1 η s

3.2. Acceleration-Weighted Control Law and Gain Update

With the control model of Equation (25) established, the control law is now specified. As the vibration concerned affects serviceability, the floor absolute acceleration is included in the performance index [42]. By Equation (7), the absolute acceleration is
a = Λ a x + Λ u u ,   Λ a = − M − 1 K ( θ c ) − M − 1 C ( θ c ) , Λ u = M − 1 η u
which does not involve the unknown excitation.
The performance index is
J c = ∫ 0 ∞ x T Q x x + a T Q a q ¨ abs + u T Ru dt
where Q x = diag ( ω q / q ref 2 , ω v / v ref 2 ) , Q a = diag ( ω a / a ref 2 ) , R = ( ω u / u max 2 ) I are normalized by the reference levels qref,vref,aref and umax following Bryson’s rule. Since a common scaling of the index does not change the optimal gain, the response weights are parameterized by the acceleration share ρa as ωa = ρa and ωq = ωv = 1 − ρa.
Substituting Equation (26) into Equation (27) introduces a cross term between the state and the control, and the index takes standard form with the weighting matrices: Q ' = Q x + Λ a T Q a Λ a , N ' = Λ a T Q a Λ u , R ' = R + Λ u T Q a Λ u .
Discretizing Equation (25) with the control force held constant over the sampling intervals gives xk+1 = Adxk + Bduk, and the optimal control law is u = −KLQRx with
K LQR = ( R ' + B d T P c B d ) − 1 ( B d T P c A d + ( N ' ) T )
where Pc is the stabilizing solution of the generalized discrete time algebraic Riccati equation
P c = A d T P c A d − ( A d T P c B d + N ' ) ( R ' + B d T P c B d ) − 1 ( B d T P c A d + ( N ' ) T ) + Q '
The gain is updated at most once every Nc time steps, and only if θc has changed by more than a prescribed threshold since the last update. Each update reassembles Ad and Bd from the current θc and solves Equation (29) anew. If Equation (29) has no stabilizing solution, the previous gain is retained.
The applied command is the feedback law limited in amplitude and rate,
u k = sat ( − K LQR x ^ k | k ) , u k ≤ u max , u k − u k − 1 ≤ u ˙ max Δ t
with sat(∙) the saturation at ±umax and a constant actuator delay imposed on the applied force.

3.3. Two-Stage Hyperparameter Tuning

Several quantities above remain undetermined by the structure and the measurements. The noise covariances of the estimator are ordinarily adjusted heuristically [34,40] and the weighting matrices of the regulator selected by rule of thumb or exhaustive search, so that a prescribed performance is difficult to attain; automated and search-based determination has accordingly been investigated for structural control [42,43,44]. The two are coupled, the covariances governing the model that reaches the controller while the controller acts on the estimator only through the structural response. They are therefore tuned in sequence by the salp swarm algorithm [45,46], the estimator first and then the controller on the estimates it produces.
The decision variables and their search range are listed in Table 1. Stage 1 determines the process noise parameters q s , γ q , γ q ˙ , q θ K and q θ C of the estimators, and Stage 2 the controller parameters ρa, ωu, Nc and τP.
In both stages, a candidate solution is represented by the position of a salp within the search bounds, and the population is updated by the leader–follower rule in [45]: the leader moves around the best solution found so far with an exploration coefficient that decreases over the iterations, and each follower moves to the midpoint between its own position and that of the preceding salp. The procedure, shown in Figure 3, is repeated until the iteration limit or a stagnation criterion is reached.
In Stage 1, the objective combines the errors of the identified excitation, state and parameters with the consistency of the innovation, the latter because the posterior covariance sets the weights of Equations (14) and (23) and must therefore agree with the actual error.
With the accepted estimator fixed, the controller stage minimizes the worst case, over the controller training set, of the frequency-weighted acceleration level of the controlled response,
min p ∈ P max m ∈ M L ¯ a , w ( p , m ) , with   L ¯ a , w ( p , m ) = 1 N s ∑ s = 1 N s L a , w , max ( p , m , s )
where p = [ρa,ωu,Nc,τp] is the controller design vector, while 𝒫 is the admissible set, ℳ the controller training set. The admissible set collects four constraints: (1) a spectral-radius margin, (2) saturation and rate-limit bounds, (3) absence of Riccati failure and (4) floors on the displacement and drift reduction rates.
Figure 3. Flowchart of the salp swarm algorithm.
Figure 3. Flowchart of the salp swarm algorithm.
Preprints 240865 g003
Since each evaluation is costly, the candidates are screened by a Gaussian-process surrogate [47]. Given the evaluated designs (pi,yi) , the surrogate predicts at a new design p* the mean and variance
μ p * = k * T ( K + σ n 2 I ) − 1 y ,   σ 2 p * = k p * , p * − k * T ( K + σ n 2 I ) − 1 k *
where K is the n × n kernel matrix, [K]ij = k(pi,pj) and k* = [k(p*,p1),…,k(p*,pn)].
A Matérn-5/2 kernel with automatic relevance determination is adopted [47], in which each design variable has its own length scale and a large length scale indicates an insensitive variable; the kernel hyperparameters are estimated by maximizing the log marginal likelihood and refitted after each new evaluation. The objective is regressed on the feasible designs only, and Gaussian-process models of the same form are fitted to the constraint margins, from which the probability of feasibility Pf(p*) is obtained.
In each generation the candidates proposed by the swarm are scored by the product of expected improvement and probability of feasibility,
a(p*) = EI(p*)Pf(p*), EI(p*) = 𝔼[max(y* − y(p*),0)]
with y* the current best objective. The highest-scoring candidates are evaluated in the closed loop, with one place reserved for the largest σ2∙Pf to keep learning the feasible boundary; the rest carry their surrogate means into the swarm update but never refresh the incumbent, which advances only on a real, feasible evaluation. Since the objective process is fitted on feasible points alone, the score reduces to Pf while these remain scarce.

4. Numerical Verification of the Proposed Method

To verify the feasibility and accuracy of the proposed estimator for the unknown excitation, structural state and parameters, as well as the effectiveness of the integration with the uncertainty-aware adaptive LQG controller, numerical simulations are conducted on a nine-story shear building subjected to a measured metro-induced base acceleration. Model mismatch, time-varying parameters and measurement noise are then introduced to assess robustness under imperfect structural knowledge.

4.1. Numerical Model and Validation Cases

The structural configuration follows the 9-story, 5-bay steel moment-resisting frame of the SAC Phase II/III benchmark [50] and is reduced here to an equivalent 9-DOF linear shear model. The first story is 5.49 m high and each of the remaining stories is 3.96 m high, giving a total structural height of 37.17 m. The lumped masses and equivalent inter-story stiffnesses fully define the simulation model. The nominal damping matrix is constructed as C0 = αM + βK0, where the Rayleigh coefficients are determined by assigning a 2% damping ratio to the first two modes. The corresponding natural frequencies are 0.773 and 2.071 Hz, respectively.
The sparse heterogeneous sensing layout in Figure 4 is selected to support the fused observation model introduced in Section 2. Absolute accelerations are measured at floors 1, 3, 6 and 9, thereby sampling the dynamic response over the lower, middle and upper portions of the structure. Inter-story drifts are measured at stories 1, 5 and 9 to provide low-frequency displacement constraints that cannot be obtained reliably by direct integration of noisy acceleration records.
Independent control forces are applied at floors 3, 6 and 9 to distribute control authority over the building height; the corresponding nominal controllability matrix also has rank 18. The same sensing and actuation configuration is used in every comparison.
Figure 4. The 9-DOF model and locations of accelerometers and inter-story drift sensors.
Figure 4. The 9-DOF model and locations of accelerometers and inter-story drift sensors.
Preprints 240865 g004
The excitation is a base acceleration record measured at the foundation of a building adjacent to a metro line during the passage of a train, shown in Figure 5. The record is 78 s long and is sampled at 50 Hz, with a peak acceleration of about 0.0041 g.
A set of validation cases are defined in Table 2, through the stiffness factors αK(nominal αK = 1), ranging from distributed mild mismatch to localized extreme mismatch. Every case is run at the nominal measurement noise level, at which zero-mean white noise is added to the acceleration channels at a 10% noise-to-signal ratio in RMS. The structural parameters are identified in the normalized form θ = α k 1 , α k 2 , … , α k 9 , α R , β R T , in which each factor scales the corresponding nominal quantity: α k i the inter-story stiffness of the i-th story, and αR,βR the mass and stiffness proportional Rayleigh coefficients. A factor of unity denotes agreement with the nominal model.
Throughout the numerical study, the recorded acceleration is treated as an unmeasured base excitation. It is introduced exclusively into the forward structural model, whereas the estimator and controller operate causally using only the available structural measurements and previously applied control commands. The exact excitation history neither enters the recursive estimation equations nor contributes to the online control law; it is retained solely as a reference for offline calibration and quantitative assessment of the reconstructed input.
Figure 5. Measured base acceleration record.
Figure 5. Measured base acceleration record.
Preprints 240865 g005
Table 2. Validation cases.
Table 2. Validation cases.
Case Validation condition Affected stories and αK Noise
C1 Nominal baseline All 1.00 1.0
C2,C3 Mild C2:2,3,4=0.92,0.88,0.94;
C3:1-9=0.85-1.00
1.0
C4,C5 Moderate C4:1,3,6=0.85,0.78,0.88
C5:7,8,9=0.78,0.82,0.72
1.0
C6 Global softening 1-9=0.85 1.0
C7,C8 As C4, noise scaled 1,3,6=0.85,0.78,0.88 0.5,2.0
C9,C10 Time-varying, 34-52s C9:3->0.60;C10:2->0.75,5->0.80 1.0
C11-C13 Localized, 1 story C11:1=0.82;C12:5=0.80;C13:8=0.85 1.0
C14-C16 Localized, 4-6 stories C14:3-6,C15:1,2,4,7,9 with αR = βR = 1.15
C16:2-7 αR = βR 0.82-0.90
1.0
C17,C18 Extreme localized C17:5=0.50;C18:3,4=0.55,0.52 1.0

4.2. Two-stage Design Optimization

The two hyperparameter sets are calibrated in sequence by the salp swarm algorithm of Section 3.3, on the scenario split of Table 3. The estimator stage is calibrated on five scenarios and the controller stage on six; the latter add the upper cluster, the four-story local mismatch and the extreme adjacent pair, so a severe mismatch enters the design set. The objective is evaluated on the training scenarios only, whereas every safety constraint is evaluated over all eighteen cases, and the remaining scenarios are withheld so the reported performance rests on a genuine hold-out.
The estimator stage returns the covariance setting of Table 4 and is thereafter frozen.
The controller stage employs the surrogate-assisted constrained search. As shown in Figure 6, the incumbent remains unchanged during the feasibility-driven cold start and then decreases stepwise after activation of the objective surrogate, reaching a budget-limited reduction of approximately 1.2 dB over 16 generations. Surrogate pre-screening required only 77 closed-loop evaluations and avoided 83 others, reducing the evaluation cost by 51.8%.
The objective surrogate is accurate over its feasible training set, with a leave-one-out coefficient of determination of 0.996, as shown in Figure 7. The relevance analysis of Figure 8 resolves the control-effort weight and the response split as the influential variables; the gain-refresh interval and the confidence scale saturate the length-scale ceiling and are unidentified within the search box, and their values are fixed instead on the independent evidence of Section 4.3.
The return design is listed in Table 5 and verified on ten noise seeds over all 18 cases, where it is feasible over the full envelope with a maximum closed-loop spectral radius of 0.965 and displacement and drift reduction rates within one percent of the reference.
Figure 8. ARD-based relevance of the controller-stage decision variables.
Figure 8. ARD-based relevance of the controller-stage decision variables.
Preprints 240865 g008
Table 5. Controller hyperparameters setting returned by Stage 2.
Table 5. Controller hyperparameters setting returned by Stage 2.
Parameter Symbol Value
Response split ρa 0.543
Control-effort weight ωu 77.3
Gain-refresh interval Nc 6
Confidence scale τp 0.086
Max. spectral radius (gate 0.97) - 0.965
Min. drift / disp. ratio (gate 0.98) - 0.98

4.3. Integration of Identification and Control Under Structural Uncertainty

This section evaluates the joint estimation–control framework over 18 uncertainty cases. For cases introduced above, the acceleration response at the base where the unknown external force acts is not measured.
Three representative mismatch patterns are considered in detail: C4, C9, and C10. To avoid presenting an excessive number of similar curves, Figure 9 shows four stiffness factors. The identified factors follow both the constant and time-varying target values closely.
The corresponding Rayleigh damping factors are presented in Figure 10. Compared with the stiffness factors, the damping estimates exhibit slightly larger fluctuations and slower convergence. This is mainly because damping contributes through the velocity-dependent term and produces a weaker response sensitivity under the low-amplitude excitation. In addition, the two Rayleigh factors are correlated through the damping matrix, making their independent identification more difficult than that of the story stiffness factors. Nevertheless, the identified damping factors remain close to true values. The representative numerical results are summarized in Table 6.
Figure 11 summarizes the identification errors over the complete uncertainty set. The story stiffness factors remain consistently identifiable, with a mean error of 0.74% and a maximum error of 2.65%. The Rayleigh factors, particularly αR, are less accurately determined, confirming their lower sensitivity under the present low-amplitude excitation and sensing arrangement.
C9 is then used to illustrate input and state reconstruction under a time-varying mismatch. As shown in Figure 12, the reconstructed excitation reproduces the dominant temporal and spectral characteristics while retaining visible discrepancies around local peaks. Unlike previous studies employing relatively strong earthquake excitation, the small amplitude of metro-induced vibration results in a lower signal-to-noise ratio and makes unknown-input reconstruction more sensitive to measurement noise.
Figure 13 compares the estimated and reference responses at the fifth floor, where absolute acceleration is not directly measured. The displacement is reconstructed accurately, whereas the velocity is more sensitive to measurement noise. These estimates, together with the identified stiffness factors, provide the feedback information required for gain adaptation.
Figure 11. Steady-state relative errors of the structural factors over the 18 cases.
Figure 11. Steady-state relative errors of the structural factors over the 18 cases.
Preprints 240865 g011
Figure 12. Reconstruction of the unknown excitation in C9.
Figure 12. Reconstruction of the unknown excitation in C9.
Preprints 240865 g012
Figure 13. Reconstruction of the state of the fifth floor in C9.
Figure 13. Reconstruction of the state of the fifth floor in C9.
Preprints 240865 g013
Four controlled configurations are compared, distinguished by the model on which the state estimation and the gain synthesis are respectively based. The nominal-model LQG combines a Kalman filter with an LQR gain, both formed on the nominal model, the structural parameters being held at their nominal values throughout. The proposed design re-synthesizes the gain from the identified parameters admitted through the confidence weight of Equation (23). The true-model LQG is granted the true structural model of each case, and its performance is that attainable when the structure is known exactly; it therefore serves as the reference against which the proposed design is assessed. A further configuration is reported as an ablation rather than as a design: it runs the full joint estimator of Section 2, so that the state estimate reflects the identified structure, but determines the control gain by parameters identified in real time, and therefore isolates the contribution of the gain adaptation alone. All four are given the same sensing, actuation and control-effort budget.
The resulting control performance is shown in Figure 14 and Figure 15. The proposed design and the ablation both reduce the roof acceleration substantially relative to the uncontrolled response, and the two are close to each other. Figure 15 compares the height-wise profiles, where the proposed design lies close to that obtained with the true structural parameters, particularly for displacement and inter-story drift, indicating that the identified model is sufficiently accurate for online gain updating.
Figure 16 compares the RMS response reductions of the four control configurations over the 18 cases, each evaluated against the uncontrolled response of the same case. As summarized in Table 7, the proposed method reduces the displacement and the inter-story drift by 70.8% and 71.8%, against 70.9% and 71.9% for the true-model LQG, and the absolute acceleration by 51.5% against 53.2%. Relative to the nominal-model design it exceeds the displacement and drift reductions in every case. That design attains a higher median acceleration reduction, 54.3%, but its performance is far less consistent: its reduction varies with a standard deviation of 6.30% and falls to 29.3% in the worst case, whereas the proposed design varies by 2.14% and does not fall below 46.4%.
The agreement with the true-model LQG is quantified in Figure 17. The proposed design departs from the reference by 0.07 and 0.10 percentage points on average in displacement and inter-story drift, and by no more than 0.17 in any case; for the ablation the corresponding figures are 1.56 and 0.97 on average and 4.64 at worst. Every one of the eighteen cases places the proposed design within half a percentage point of the reference in both quantities; the ablation achieves this in seven. The cross-case correlations are 1.000, 1.000 and 0.993 for the three response quantities, the largest single shortfall being 2.49 percentage points in absolute acceleration. The noise in the estimated velocity introduces a small high-frequency component into the control force, which the structure attenuates in the displacement and the inter-story drift but transmits undiminished to the floor accelerations, where the residual shortfall therefore appears.
The control effort required by the proposed design is comparable to that of the true-model LQG in both RMS and peak, as shown in Table 8. Retaining the nominal gain raises the peak demand, which grows with the severity of the mismatch.
Figure 18 presents the control force time history of the top floor actuator in C9. Without gain adaptation, the control force becomes erratic and exhibits pronounced peaks while the parameter estimates remain unsettled. By contrast, the proposed design produces a steadier control force at a lower level, thereby reducing the control effort. No configuration saturated the actuator, engaged the rate limiter, or failed to return a stabilizing solution of Equation (29).
Figure 18. Comparison of the time history of the roof control force in C9.
Figure 18. Comparison of the time history of the roof control force in C9.
Preprints 240865 g018
Table 8. Control effort over the 18 cases.
Table 8. Control effort over the 18 cases.
Configuration Force (kN) Peak force (kN) Peak capacity (%)
Nominal-model 0.98(0.95-1.38) 3.98(3.58-6.03) 12.1
Ablation 1.58(1.52-2.65) 7.00(6.53-16.78) 33.6
Proposed 1.54(1.52-1.57) 6.75(6.24-7.09) 14.2
True-model 1.49(1.47-1.51) 6.46(5.96-6.89) 13.8
Note: Values are reported as average (minimum-maximum).

5. Conclusions

This paper proposed an integrated identification and control method for buildings under unknown metro-induced excitation, aimed at sustaining the serviceability of buildings adjacent to metro lines. A GEKF-UI estimated the structural states, story-wise parameters and base excitation from sparse acceleration and drift measurements. To mitigate the ill-posedness of recovering the excitation from weak, low-SNR responses, the input regularization was updated at each step from its posterior variance. The estimated states were fed back through an LQG controller whose gain was governed by a confidence index built from the posterior uncertainty of the identified parameters, so that the identification uncertainty entered the control design. The estimator and controller hyperparameters were tuned offline in two stages. Numerical verification on the nine-story SAC benchmark building under a measured metro record and 18 uncertainty cases leads to the following conclusions.
(1) With the story-wise stiffness factors and Rayleigh damping factors augmented into the state vector, the estimator identified the time-varying and biased structural parameters together with the structural states and the base excitation from sparse acceleration and drift measurements. The mean and maximum errors of the identified stiffness factors over the 18 cases were 0.74% and 2.65%. The posterior-variance-driven regularization yielded a stable reconstruction of the excitation under low-amplitude metro-induced vibration. The damping factors and local excitation peaks remained more sensitive to noise, although their principal characteristics were retained.
(2) The proposed controller reduced the RMS displacement, inter-story drift and absolute acceleration by 70.8%, 71.8% and 51.5% on average, differing from the true-model LQG by less than 0.1 percentage points in displacement and drift and correlating with it at 0.993 in acceleration. Relative to the nominal-model LQG, the displacement and drift reductions increased by 6.3 and 6.8 percentage points, and the worst-case acceleration reduction rose from 29.3% to 46.4%. Without gain adaptation, the peak control force reached 16.8 kN and the RMS force varied between 1.52 and 2.65 kN across the cases. The proposed controller kept the peak force below 7.1 kN, close to that of the true-model LQG, and the RMS force within 1.52–1.57 kN, achieving comparable vibration suppression at a lower and more consistent control effort.
(3) The noise covariances of the estimator and the weights of the controller are determined neither by the structure nor by the measurements and would otherwise have to be specified manually in advance. The two-stage salp swarm search provided a unified design that improved the frequency-weighted control objective by about 1.2 dB and applied to all cases without case-by-case tuning. Meanwhile, the Gaussian-process surrogate reduced the number of closed-loop simulations, saving computational time and cost.
The proposed framework has been demonstrated numerically. Future work will further validate the method through experimental studies and long-term field monitoring. In addition, the parameters of the estimation and control stages are currently optimized using multiple representative cases. Deep learning may be introduced to enable the online adaptive updating of covariance-related and control parameters, thereby reducing the dependence on extensive training.

Author Contributions

Conceptualization, Y.K. and H.T.; methodology, Y.K. and Y.D.; software, Y.K.; validation, Y.K. and Y.D.; formal analysis, Y.K.; investigation, Y.D.; resources, Y.K.; data curation, Y.D.; writing—original draft preparation, Y.K. and Y.D.; writing—review and editing, Y.K. and H.T.; visualization, Y.K.; supervision, Y.K. and H.T.; project administration, Y.K.; funding acquisition, H.T. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by National Natural Science Foundation of China (Grant No. 52378184).

Data Availability Statement

The original contributions presented in this study are included in the article. Further inquiries can be directed to the corresponding author.

Conflicts of Interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

References

  1. Connolly, D.P.; Marecki, G.P.; Kouroussis, G.; Thalassinakis, I.; Woodward, P.K. The growth of railway ground vibration problems: A review. Sci. Total Environ. 2016, 568, 1276–1282. [CrossRef]
  2. Kouroussis, G.; Connolly, D.P.; Verlinden, O. Railway-induced ground vibrations: a review of vehicle effects. Int. J. Rail Transp. 2014, 2, 69–110. [CrossRef]
  3. Sanayei, M.; Maurya, P.; Moore, J.A. Measurement of building foundation and ground-borne vibrations due to surface trains and subways. Eng. Struct. 2013, 53, 102–111. [CrossRef]
  4. Qiu, Y.; Zou, C.; Hu, J.; Chen, J. Prediction and mitigation of building vibrations caused by train operations on concrete floors. Appl. Acoust. 2024, 219, 109941. [CrossRef]
  5. Xie, W.; Hua, Y. Structural vibration comfort: A review of recent developments. Buildings 2024, 14, 1592. [CrossRef]
  6. Zini, G.; Betti, M.; Bartoli, G. Experimental analysis of the traffic-induced-vibration on an ancient lodge. Struct. Control Health Monit. 2022, 29, e2900. [CrossRef]
  7. Spencer, B.F., Jr.; Nagarajaiah, S. State of the art of structural control. J. Struct. Eng. 2003, 129, 845–856.
  8. Casciati, F.; Rodellar, J.; Yildirim, U. Active and semi-active control of structures, theory and applications: A review of recent advances. J. Intell. Mater. Syst. Struct. 2012, 23, 1181–1195. [CrossRef]
  9. Warn, G.P.; Ryan, K.L. A review of seismic isolation for buildings: historical development and research needs. Buildings 2012, 2, 300–325. [CrossRef]
  10. Elias, S.; Matsagar, V. Research developments in vibration control of structures using passive tuned mass dampers. Annu. Rev. Control 2017, 44, 129–156. [CrossRef]
  11. Kang, J.; Zhao, Z.; Xie, L.; Wan, C.; Xue, S. Proportional distribution pattern and modal principle of tuned viscous mass dampers for multi-degree-of-freedom structures. Eng. Struct. 2025, 322, 119175. [CrossRef]
  12. Zhang, L.; Xue, S.; Chen, T.; Yang, Z.; Zhang, R.; Xie, L. A nonlinear inertia-enabled vibration absorber using a yoke-type inerter. Nonlinear Dyn. 2026, 114, 560. [CrossRef]
  13. Zhang, L.; Xue, S.; Chen, T.; Xie, L.; Zhang, R.; Yang, Z. Performance assessment of crank inerters integrated into base-isolated structures for multi-level seismic protection. Eng. Struct. 2026, 357, 122490. [CrossRef]
  14. Soong, T.T. Active Structural Control: Theory and Practice; Longman Scientific and Technical: New York, NY, USA, 1990.
  15. Lei, Y.; Wu, Y.; Li, T. Identification of non-linear structural parameters under limited input and output measurements. Int. J. Non-Linear Mech. 2012, 47, 1141–1146. [CrossRef]
  16. Yang, J.N.; Lin, S.; Huang, H.; Zhou, L. An adaptive extended Kalman filter for structural damage identification. Struct. Control Health Monit. 2006, 13, 849–867. [CrossRef]
  17. Yang, J.N.; Pan, S.; Huang, H. An adaptive extended Kalman filter for structural damage identifications II: Unknown inputs. Struct. Control Health Monit. 2007, 14, 497–521. [CrossRef]
  18. Gillijns, S.; De Moor, B. Unbiased minimum-variance input and state estimation for linear discrete-time systems with direct feedthrough. Automatica 2007, 43, 934–937.
  19. Xu, Y.L.; Chen, B. Integrated vibration control and health monitoring of building structures using semi-active friction dampers: Part I, Methodology. Eng. Struct. 2008, 30, 1789–1801. [CrossRef]
  20. Chen, B.; Xu, Y.L. Integrated vibration control and health monitoring of building structures using semi-active friction dampers: Part II, Numerical investigation. Eng. Struct. 2008, 30, 573–587. [CrossRef]
  21. Lei, Y.; Liu, C.; Wu, S.Z. Integration of decentralized structural control and the identification of unknown inputs for tall shear building models under unknown earthquake excitation. Eng. Struct. 2013, 52, 306–316.
  22. Lei, Y.; Zhou, H.; Liu, L. An on-line integration technique for structural damage detection and active optimal vibration control. Int. J. Struct. Stab. Dyn. 2014, 14, 1440003. [CrossRef]
  23. He, J.; Xu, Y.L.; Zhan, S.; Huang, Q. Structural control and health monitoring of building structures with unknown ground excitations: Experimental investigation. J. Sound Vib. 2017, 390, 23–38. [CrossRef]
  24. Su, H.; Liu, L.; Wang, S.; Wang, Y.; Lei, Y. Integration of ATMD-structure coupling system identification with semi-active vibration control of high-rise buildings under unknown wind loads. Mech. Syst. Signal Process. 2026, 248, 113993. [CrossRef]
  25. Pan, S.; Xiao, D.; Xing, S.; Law, S.S.; Du, P.; Li, Y. A general extended Kalman filter for simultaneous estimation of system and unknown inputs. Eng. Struct. 2016, 109, 85–98. [CrossRef]
  26. Lei, Y.; Luo, S.J.; Su, Y. Data fusion based improved Kalman filter with unknown inputs and without collocated acceleration measurements. Smart Struct. Syst. 2016, 18, 375–387. [CrossRef]
  27. Lei, Y.; Lu, J.; Huang, J.; Chen, S. A general synthesis of identification and vibration control of building structures under unknown excitations. Mech. Syst. Signal Process. 2020, 143, 106803. [CrossRef]
  28. Huang, J.S.; Li, X.Z.; Zhang, F.; Lei, Y. Identification of joint structural state and earthquake input based on a generalized Kalman filter with unknown input. Mech. Syst. Signal Process. 2021, 151, 107362. [CrossRef]
  29. Wang, S.; Lei, Y. An unscented Kalman filter under unknown input without direct feedthrough for joint input and system identification of structural systems. Mech. Syst. Signal Process. 2024, 208, 110951. [CrossRef]
  30. Jacquelin, E.; Bennani, A.; Hamelin, P. Force reconstruction: analysis and regularization of a deconvolution problem. J. Sound Vib. 2003, 265, 81–107. [CrossRef]
  31. Hansen, P.C. Analysis of discrete ill-posed problems by means of the L-curve. SIAM Rev. 1992, 34, 561–580. [CrossRef]
  32. Huang, J.; Lei, Y.; Yang, X.; Li, X.; Xu, K.; Wang, F.; Chen, X. Robust identification of distributed dynamic loads acting on multi-degree-of-freedom structures based on sparse measurement. Mech. Syst. Signal Process. 2025, 228, 112417. [CrossRef]
  33. Lourens, E.; Reynders, E.; De Roeck, G.; Degrande, G.; Lombaert, G. An augmented Kalman filter for force identification in structural dynamics. Mech. Syst. Signal Process. 2012, 27, 446–460. [CrossRef]
  34. Vettori, S.; Di Lorenzo, E.; Peeters, B.; Luczak, M.M.; Chatzi, E. An adaptive-noise Augmented Kalman Filter approach for input-state estimation in structural dynamics. Mech. Syst. Signal Process. 2023, 184, 109654. [CrossRef]
  35. Yuen, K.V.; Shi, Y.F.; Beck, J.L.; Lam, H.F. Structural protection using MR dampers with clipped robust reliability-based control. Struct. Multidiscip. Optim. 2007, 34, 431–443. [CrossRef]
  36. Xu, K.; Chen, L.; Che, Q.; Lopes, A.M.; Hu, Q.; Zhu, K. A novel adaptive fuzzy variable fractional-order sliding mode controller for vibration control of building structures under unknown earthquakes. Structures 2026, 92, 112858. [CrossRef]
  37. Astrom, K.J.; Wittenmark, B. Adaptive Control, 2nd ed.; Addison-Wesley: Reading, MA, USA, 1995.
  38. Cramer, H. Mathematical Methods of Statistics; Princeton University Press: Princeton, NJ, USA, 1946.
  39. Feng, Z.; Zhang, J.; Katafygiotis, L.; Hua, X.; Chen, Z. Bayesian spectral decomposition for efficient modal identification using ambient vibration. Struct. Control Health Monit. 2024, 1, 5137641. [CrossRef]
  40. Greś, S.; Döhler, M.; Dertimanis, V.K.; Chatzi, E.N. Subspace-based noise covariance estimation for the Kalman filter in virtual sensing applications. Mech. Syst. Signal Process. 2024, 222, 111772. [CrossRef]
  41. Chen, Z.; Biggie, H.; Ahmed, N.; Julier, S.; Heckman, C. Kalman filter auto-tuning with consistent and robust Bayesian optimization. IEEE Trans. Aerosp. Electron. Syst. 2024, 60, 2236–2250. [CrossRef]
  42. Miyamoto, K.; She, J.; Sato, D.; Yasuo, N. Automatic determination of LQR weighting matrices for active structural control. Eng. Struct. 2018, 174, 308–321. [CrossRef]
  43. Kumar, G.; Kumar, A.; Jakka, R.S. An adaptive LQR controller based on PSO and maximum predominant frequency approach for semi-active control scheme using MR damper. Mech. Ind. 2018, 19, 109. [CrossRef]
  44. Chha, H.; Peng, Y. Adaptive linear quadratic regulator for optimal structural control based on wavelet transform and genetic algorithm. Eng. Comput. 2023, 40, 1016–1039. [CrossRef]
  45. Mirjalili, S.; Gandomi, A.H.; Mirjalili, S.Z.; Saremi, S.; Faris, H.; Mirjalili, S.M. Salp Swarm Algorithm: A bio-inspired optimizer for engineering design problems. Adv. Eng. Softw. 2017, 114, 163–191.
  46. Baygi, S.M.H.; Karsaz, A. A hybrid optimal PID-LQR control of structural system: A case study of salp swarm optimization. In Proceedings of the 3rd Conference on Swarm Intelligence and Evolutionary Computation (CSIEC), Bam, Iran, 2018.
  47. Rasmussen, C.E.; Williams, C.K.I. Gaussian Processes for Machine Learning; MIT Press: Cambridge, MA, USA, 2006.
  48. Jones, D.R.; Schonlau, M.; Welch, W.J. Efficient global optimization of expensive black-box functions. J. Glob. Optim. 1998, 13, 455–492. [CrossRef]
  49. He, C.; Zhang, Y.; Gong, D.; Ji, X. A review of surrogate-assisted evolutionary algorithms for expensive optimization problems. Expert Syst. Appl. 2023, 217, 119495. [CrossRef]
  50. Ohtori, Y.; Christenson, R.E.; Spencer, B.F., Jr.; Dyke, S.J. Benchmark control problems for seismically excited nonlinear buildings. J. Eng. Mech. 2004, 130, 366–385. [CrossRef]
Figure 1. Recursive procedure of the proposed approach of structural identification.
Figure 1. Recursive procedure of the proposed approach of structural identification.
Preprints 240865 g001
Figure 2. Framework of the integrated estimation and adaptive control, with the two-stage offline tuning of the hyperparameters.
Figure 2. Framework of the integrated estimation and adaptive control, with the two-stage offline tuning of the hyperparameters.
Preprints 240865 g002
Figure 6. Convergence of the surrogate-assisted search over the generations.
Figure 6. Convergence of the surrogate-assisted search over the generations.
Preprints 240865 g006
Figure 7. Leave-one-out predictive accuracy of the objective surrogate.
Figure 7. Leave-one-out predictive accuracy of the objective surrogate.
Preprints 240865 g007
Figure 9. Convergence of the stiffness factors.
Figure 9. Convergence of the stiffness factors.
Preprints 240865 g009
Figure 10. Convergence of the damping factors.
Figure 10. Convergence of the damping factors.
Preprints 240865 g010
Figure 14. Comparison of the time history of the roof absolute acceleration in C9.
Figure 14. Comparison of the time history of the roof absolute acceleration in C9.
Preprints 240865 g014
Figure 15. Comparisons of control performance in C9: (a) max displacement responses, (b) max inter-story drift, (c) max absolute acceleration.
Figure 15. Comparisons of control performance in C9: (a) max displacement responses, (b) max inter-story drift, (c) max absolute acceleration.
Preprints 240865 g015
Figure 16. RMS response reduction of four control configurations over the 18 cases.
Figure 16. RMS response reduction of four control configurations over the 18 cases.
Preprints 240865 g016
Figure 17. Agreement between the proposed method and the true-model LQG over the 18 cases.
Figure 17. Agreement between the proposed method and the true-model LQG over the 18 cases.
Preprints 240865 g017
Table 1. Decision variables and search domains of the two-stage design optimization.
Table 1. Decision variables and search domains of the two-stage design optimization.
Stage Parameter Search interval Role
1 qs 10−8 − 10−1 Random-walk process variance of the unknown excitation
1 γ q , γ q ˙ γq ∈ 10−6 − 10−2
γ q ˙ ∈ 10 − 5 − 10 − 1
State-process noise scales on the displacement and velocity partitions
1 q θ K , q θ C 10−10 − 10−4 Random-walk intensity of the nine per-story stiffness factors and of the two Rayleigh factor
2 ρa,ωu ρa ∈ [0.1,0.9]
ωu ∈ 100.5 − 103
Set response penalties relative to control effort weight
2 Nc,τP Nc ∈ 20 − 26
τP ∈ 10−2 − 100.3
Set the rate and the confidence at which the identified model is allowed to enter the gain
Table 3. Training and hold-out partition of cases.
Table 3. Training and hold-out partition of cases.
Stage Objective on Constraint on
1/Estimator C1, C3, C4, C8, C10 -
2/Controller C1, C4, C5, C8, C14,C18 all cases
Hold-out the other cases -
Table 4. Estimator hyperparameters setting returned by Stage 1.
Table 4. Estimator hyperparameters setting returned by Stage 1.
Parameter Symbol Value
Unknown-input process variance qs 3.36 × 10−4
State-process scale, displacement γq 1.11 × 10−4
State-process scale, velocity γ q ˙ 3.39 × 10−4
Stiffness random-walk intensity q θ K 8.34 × 10−6
Rayleigh random-walk intensity q θ C 1.77 × 10−7
Table 6. Identified structural parameters and error.
Table 6. Identified structural parameters and error.
Parameter C4 true/identified error (%) C9 true/identified error (%) C10 true/identified error (%)
α K 2 1.000/0.998 0.21 1.000/1.003 0.29 0.750/0.756 0.81
α K 3 0.780/0.783 0.38 0.600/0.607 1.16 1.000/1.003 0.34
α K 5 1.000/1.005 0.48 1.000/1.003 0.32 0.800/0.809 1.13
α K 6 0.880/0.860 2.27 1.000/0.984 1.63 1.000/0.979 2.03
αR 1.000/0.998 0.04 1.000/1.005 0.56 1.000/0.976 2.37
βR 1.000/1.026 2.66 1.000/1.023 2.32 1.000/1.025 2.48
Note: For constant parameters, the identified value is the average over the final 10 s. For a time-varying stiffness factor, the identified value is averaged over the maximum-mismatch plateau.
Table 7. RMS response reduction rate over the 18 cases.
Table 7. RMS response reduction rate over the 18 cases.
Configuration Displacement (%) Inter-story drift (%) Acceleration (%)
Nominal-model 64.7(53.9-71.1) 64.8(56.1-71.0) 54.3(29.3-60.5)
Ablation 69.3(64.7-74.5) 71.9(64.3-75.1) 51.7(48.0-54.8)
Proposed 70.8(65.0-74.5) 71.8(66.9-75.1) 51.5(46.4-54.4)
True-model 70.9(65.1-74.5) 71.9(67.1-75.2) 53.2(48.7-56.5)
Note: Values are reported as average (minimum-maximum).
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.
Copyright: This open access article is published under a Creative Commons CC BY 4.0 license, which permit the free download, distribution, and reuse, provided that the author and preprint are cited in any reuse.