Submitted:
24 October 2026
Posted:
27 October 2026
You are already at the latest version
Abstract
Magnetic treatment of injection water has been proposed as a low-cost, chemical-free means of improving waterflooding, but laboratory evidence that links field intensity, pressure, electrokinetic behaviour and oil displacement remains limited. This study investigates the effect of a constant transverse magnetic field (40–150 mT) applied to injection water upstream of a linear sand–clay (75:25) porous-medium model, 120.4 cm long and 4.2 cm in internal diameter. First, single-phase water flow was examined at 1.6–30.4 atm, recording the potential difference, electrical resistance and outflow rate. Second, three oils with kinematic viscosities of 24.9 mm²/s (paraffin oil), 47.49 mm²/s (machine oil) and 198 mm²/s (refined transformer oil) were displaced by untreated and magnetically treated water at pressures up to 35.2 atm. Magnetic treatment lowered the potential difference and resistance of the water-saturated medium and increased the water outflow rate. In oil displacement, the final oil displacement coefficient increased from 47.38% to 60.64% for machine oil, from 42.30% to 54.32% for paraffin oil and from 37.08% to 50.36% for transformer oil at the most effective intensity of 125 mT, while the water displacement coefficient decreased. Magnetic treatment also stabilised the electrokinetic response during displacement. A generalised filtration law that includes electromagnetic forces is presented.
Keywords:
magnetic water treatment
; enhanced oil recovery
; waterflooding
; electrokinetic phenomena
; porous media
; displacement efficiency
; oil viscosity
; streaming potential
1. Introduction
Improving the development efficiency of oil fields is of major importance for the effective use of energy resources. Conventional production methods recover only part of the oil in place, and the volume of residual oil remaining in reservoirs is commonly reported to be 50–60% [1,2]. Enhanced oil recovery (EOR) methods are traditionally divided into primary, secondary and tertiary stages that follow the chronological sequence of reservoir production [1,2]. Primary recovery relies on the natural energy of the reservoir, secondary recovery is today largely synonymous with waterflooding, and tertiary methods—thermal, physicochemical and physical-hydrodynamic—are applied when waterflooding becomes uneconomic [1,2,3].
EOR processes can be classified into mobility-control, chemical, miscible, thermal and other (for example, microbial) processes [4,5,6,7]. Polymer flooding improves macroscopic sweep by reducing the mobility of the displacing water [4]; surfactant-based processes reduce interfacial tension between the displacing fluid and oil [5,6]; and thermal processes reduce oil viscosity and are preferred for heavy, low-API oils [7,8]. Each of these approaches has limitations related to cost, reservoir conditions or environmental impact, which motivates continued research on alternative technologies [9].
Although waterflooding is the most widely applied recovery technique, it is affected by low displacement efficiency, high water cut and problems caused by reservoir heterogeneity [10,11,12]. These limitations have directed researchers towards methods based on physical fields—magnetic, electric or ultrasonic. Among them, electromagnetic heating of heavy oil has received considerable attention [13], whereas the magnetic treatment of injection water, which does not rely on heating, has been studied much less.
Exposure of water to a magnetic field can change its structural and dynamic properties, including viscosity, ion mobility and surface tension, and can reduce scale formation [14]. These changes may alter the interaction between the injected fluid and the reservoir rock and thereby improve the displacement of trapped oil. The effectiveness of magnetic treatment depends on the correct choice of field intensity: several earlier attempts to increase oil recovery by magnetically treated water gave unsatisfactory or even negative results, which has been attributed to the use of an alternating field or to an incorrectly chosen field intensity [14]. Laboratory and field studies carried out at the Department of Oil and Gas Engineering of the Azerbaijan State Oil and Industry University since the 1970s showed that treating injection water with a constant transverse magnetic field increased the injectivity of injection wells by about 30% and increased the production of surrounding wells, while reducing corrosion of field equipment [14,15].
The interaction of a magnetic field with reservoir fluids is explained by electrokinetic theory. When a liquid moves through a porous medium, a streaming potential (the Quincke effect) is generated and the pore surface becomes electrically charged; this excess potential is considered to oppose fluid motion and to reduce the permeability of the rock [14,16]. Darcy’s law, and its generalisation by A.Kh. Mirzajanzade, who introduced the initial pressure gradient for the flow of non-Newtonian oils [16,17], take into account the properties of the saturating fluids and rocks but not the electromagnetic interactions that arise during flow.
The authors have previously reported parts of this research programme in journal and conference publications [18,19,20,21,22,23,24,25]. The present article brings together, in one consistent framework, (i) a generalised filtration law that includes electromagnetic forces, (ii) laboratory measurements of the potential difference, electrical resistance and outflow rate of water flowing through a sand–clay porous medium under magnetic fields of 40–150 mT and pressures of 1.6–30.4 atm, and (iii) water-displacement experiments with three oils of different physicochemical properties using untreated and magnetically treated water. The objective is to determine how the magnetic field intensity and pressure affect the flow and electrokinetic behaviour of water and the oil displacement efficiency, and to identify the most effective field intensity for oils of different viscosity.
2. Theoretical Background: Generalised Filtration Law Including Electromagnetic Forces
Darcy’s law, in the form used in oil production, is written as [26]
where Q is the flow rate of the liquid through the porous medium, k0 is the initial permeability of the porous medium, P1 and P2 are the pressures at the inlet and outlet of the sample, S is the filtration area, μ is the viscosity of the filtered liquid and l is the length of the porous medium.
Before development, the surface of the porous reservoir medium possesses an initial magnetic field strength determined by the adsorption layer on the rock surface, which depends on the rock composition, the properties of the saturating fluid (mainly viscosity), the depth and the coordinates of the reservoir. At the start of flow, the rock has an initial permeability k0 and an initial production rate Q0. Once the fluid moves, a streaming potential is generated, and the pore surface is charged to a potential that depends on the electrical capacitance of the rock, in the manner of a capacitor. The excess potential is radiated by the pore surface as an electromagnetic field that hinders fluid motion and reduces permeability. Laboratory filtration of gas-free Devonian oil through sandstone showed a high initial production rate followed by a significant decline [14,16]. These observations make it necessary to account for electromagnetic forces in Darcy’s law.
A charge q moving with velocity v experiences, in addition to the electric force qE, a magnetic force, so that the total electromagnetic force is
F = qE + q v × B
For a charge moving along the Ox axis with the field directed perpendicular to that axis, and with B replaced by the field intensity H as in the original derivation, the projection of the electromagnetic force is
FEM = qE + qυH
To introduce the electromagnetic forces into Equation (1), the flow rate and pressures are expressed through the filtration velocity υ and the forces F1 and F2 acting on the inlet and outlet faces:
Substituting Equation (4) into Equation (1) and rearranging gives
Adding the streaming-potential (Quincke) contribution and the electromagnetic force (3) to the right-hand side yields
Collecting the terms in υ, dividing by S, using P = F/S and multiplying by S, the generalised law of liquid filtration in a porous medium is obtained:
For E = 0 and H = 0, Equation (7) reduces to Darcy’s law (1). The values of E, q and H entering Equation (7) are to be determined experimentally during filtration. Equation (7) shows that, within this framework, the filtration rate and therefore the amount of oil recovered can be changed by adjusting the strength of the applied magnetic field.
3. Materials and Methods
3.1. Porous Medium
A linear reservoir model consisting of a high-pressure column with an internal diameter of 4.2 cm and a length of 120.4 cm was used. The inner wall of the column was coated with epoxy adhesive, which was distributed uniformly by periodically rotating the tube and allowed to cure fully at room temperature for several days. The coating electrically insulated the porous medium from the column body and prevented fluid bypass along the wall. The column was filled with a mixture of 75% quartz sand and 25% clay (mass ratio 3:1). To obtain a compact medium, each new portion of the mixture was added and compacted by vertical vibration and tamping, after which the upper flange was tightened to apply an overburden load; filling continued until vibration and load no longer changed the degree of compaction, so that a pressure-independent permeability was obtained. The mass of the empty column was 6.075 kg and that of the filled column 7.245 kg. Both ends of the column were closed with metal heads sealed with rubber rings and equipped with pressure gauges and high-pressure valves. The tightness of the system was checked at 1–2 atm before each experiment. The sand component consisted of quartz (SiO2), in which each silicon atom is tetrahedrally coordinated by four oxygen atoms (Si–O bond length about 1.60 Å). The clay component was illite, a layered aluminosilicate whose SiO2 tetrahedral and Al2O3 octahedral sheets are held together by interlayer potassium (K⁺) ions; on contact with water, the clay swells as water enters the interlayer space, and an electrical double layer and zeta potential form on the negatively charged clay surfaces, which affect the filtration and permeability of clay-bearing rocks. The air permeability of the porous medium was determined by a standard method, and the pore volume was determined both gravimetrically and by filling the medium with air to a given pressure and applying the gas equation of state; the grain-size distribution, porosity and pore volume values are not reported in this study. For reference, the gas permeability of a sand–clay model of the same composition and dimensions, packed by the same procedure (packed mass 1665 g), was measured with nitrogen, methane and carbon dioxide at pressure differences of 1.25, 2.5 and 5 atm [27]. At a pressure difference of 1.25 atm, the initial permeability was 4.88 mD (N2), 3.78 mD (CH4) and 3.06 mD (CO2); it decreased sharply during the first 100 s of flow and with increasing pressure difference, reaching 0.25, 0.17 and 0.20 mD, respectively, at 5 atm.
To measure the potential difference across the porous medium, high-resistance nichrome wire electrodes were used. Each wire was in contact with the porous medium at one end and was surrounded by a fluoroplastic layer that insulated it from the rock while remaining conductive with respect to the liquid.
3.2. Fluids
Tap water was used as the displacing agent. Its physicochemical properties were analysed before and after magnetic treatment (Table 1).
Three oils with different physicochemical properties were used as model oils representing crude oils of different rheology: refined transformer oil, machine oil and paraffin oil. Their kinematic viscosities were measured with an Engler capillary viscometer and their densities with a hydrometer (Table 2).
3.3. Experimental Setup
The experimental setup is shown in Figure 1 and Figure 2. It consists of a УСА-4А regulator (1), a SUNTEK 2000 VA voltage regulator (2), a volt-ammeter (3), an electromagnet (4), a measuring cylinder (5), valves (6, 10, 13, 15, 17), pressure gauges (7, 9, 16), the high-pressure column (8), a URV-2M high-input-impedance potentiometer (11), a thermostat (12), a PVT-type high-pressure bomb (14), a liquid tank (18) and a measuring press (19).
The PVT bomb has a volume of 800 mL, a diameter of 8 cm and a height of 20 cm. It was filled with water and connected to the column through a copper tube passing through the field of the electromagnet. The tubing must be made of a non-magnetic material that does not screen the magnetic field; copper was used in this study. Machine oil, used as the pressure-transmitting agent, was supplied from the tank to the bomb by the measuring press; the oil entering the bomb from below moved the piston, which displaced the water from the bomb into the porous medium.
The electromagnet was installed on the line near the column inlet (Figure 3); its power is 1.3 kW, its operating current 4.2 A and its voltage 220 V. The electromagnet was intended to expose the water to the magnetic field before it entered the column. Because the electromagnet operates with a constant magnetic field but is fed from an alternating-current source, a voltage regulator with a built-in rectifier was used to convert and regulate the current. Different magnetic induction values were obtained by changing the voltage U of the regulator, and the resulting field intensity H was measured with a magnetometer (Table 3). The device for magnetic treatment of injection water is protected as a utility model [28].
3.4. Procedure for Water Flow Experiments
The porous medium and the test liquid were evacuated beforehand, and the medium was then saturated from the PVT bomb; about ten pore volumes of liquid were passed through it. To remove air completely, the pressure in the system was periodically raised and the liquid was then sharply released.
Before each experiment, the initial potential difference and resistance were recorded. Oil was then pumped into the bomb by the measuring press at 1.6 atm, displacing the water from the bomb into the porous medium, and the pressure was held constant. After a 2 min waiting period to allow complete saturation of the medium with water, the column outlet was opened, the volume of outflowing water was measured with the measuring cylinder, and the resistance and potential difference were recorded simultaneously. The procedure was repeated at pressure steps of 3.2 atm up to 30.4 atm, without a magnetic field and at field intensities of 40, 80, 107, 125, 140 and 150 mT. These intensities were selected on the basis of the literature, preliminary experimental results and practical feasibility under field conditions.
3.5. Procedure for Oil Displacement Experiments
The porous medium was saturated with the oil under study using the PVT bomb, after the oil and the medium had been evacuated with a vacuum pump; the pressure was periodically raised and the oil sharply released to remove residual air. The oil was transferred in a single-phase state from the bomb into the medium by means of the press. For each oil, 800 mL were injected, and the oil volume collected at the outlet at the end of injection was recorded: 355 mL (44.3%) for transformer oil, 380 mL (47.5%) for machine oil and 365 mL (45.6%) for paraffin oil.
The oil remaining in the medium was then displaced by water. The bomb piston was lowered by applying 4–5 atm of gas (nitrogen or carbon dioxide), the bomb was evacuated for 10–15 min, and 800 mL of water was admitted through a funnel while preventing air entry. The water was then displaced from the bomb into the porous medium by the press. The pressure was increased stepwise by 1.6 atm every 5 min, from 1.6 atm to 35.2 atm. At each 5 min interval, the volume of water entering the system, the potential difference, the resistance and the volumes of oil and water leaving the column were recorded. The oil displacement coefficient ηoil and the water displacement coefficient ηw are reported as percentages, ηoil relative to the oil volume retained in the medium after saturation and ηw relative to the 800 mL of water in the bomb.
The displacement experiments with magnetically treated water followed the same procedure, with the electromagnet operating at 40, 80, 107, 125, 140 or 150 mT. In these experiments, results were recorded every 10 min (every 3.2 atm).
3.6. Flow of the Oils Under Normal Conditions
To determine the flow behaviour of the oils outside the porous medium, a separate setup consisting of a liquid tank, pressure gauge, valve, measuring press and measuring cylinder was used. The flow rate of each oil, and of water for comparison, was measured as a function of time and pressure; the experiments were repeated several times.
3.7. Control of Geomagnetic Activity
Geomagnetic storms are disturbances of the Earth’s magnetic field that can affect electromagnets, systems based on electromagnetic fields and sensitive experimental equipment, causing measurement errors [29,30,31,32]. The geomagnetic activity level in Baku during October 2024, when the experiments were conducted, was evaluated on an eight-level scale (1—no significant disturbance; 2—minor disturbances; 3—weak storm; 4—small storm; 5—moderate storm; 6—strong storm; 7—severe storm; 8—extreme storm) [29]. Experiments were carried out on days with “minor disturbances”, and the geomagnetic activity was monitored in real time on each day of the magnetic experiments; any sudden changes were recorded and taken into account in the interpretation.
4. Results
4.1. Water Flow Through the Porous Medium Under Magnetic Treatment
The potential difference, resistance and water outflow rate measured as functions of pressure are shown in Figure 4.
Without a magnetic field, the potential difference decreased from 92.2 mV at 1.6 atm to 45.4 mV at 20.8 atm and then increased slightly to 48.5 mV at 30.4 atm (Figure 4a). The resistance followed the same pattern, decreasing from 140.8 kΩ to a minimum of 74.6 kΩ at 20.8 atm and then increasing to 90.4 kΩ at 30.4 atm (Figure 4b). The water outflow rate increased from 0.1 cm³/min at 1.6 atm to a maximum of 6.2 cm³/min at 20.8 atm and decreased to 3.8 cm³/min at 30.4 atm (Figure 4c).
With magnetic treatment, the potential difference and resistance decreased more steeply as pressure increased and stabilised at lower values than in the untreated case. For all field intensities, the minima of the potential difference and resistance occurred at 20.8 atm. The lowest values were obtained at 125 mT: 20.2 mV and 40.3 kΩ at 20.8 atm, compared with 45.4 mV and 74.6 kΩ without the field. Above 20.8 atm, the resistance under magnetic treatment remained below the untreated values at all pressures; at 30.4 atm, it was 59.1 kΩ at 125 mT and 62.2 kΩ at 107 mT, compared with 90.4 kΩ without the field. At the lowest pressure (1.6 atm), the effect of the field on the potential difference was not uniform: values both above (97.7 mV at 107 mT) and below (74.6 mV at 125 mT) the untreated value were recorded.
Magnetic treatment increased the water outflow rate at all pressures. Up to 20.8 atm, the outflow rate increased with field intensity, reaching a maximum of 9.2 cm³/min at 150 mT and 20.8 atm. Above 20.8 atm, the outflow rate decreased for all conditions, but remained above the untreated values; at 27.2 atm and 30.4 atm, the highest outflow rates were obtained at 107 mT (6.8 and 6.0 cm³/min, respectively).
4.2. Water Displacement of Oils Without Magnetic Treatment
The results of displacing the three oils with untreated water are shown in Figure 5. Oil first appeared at the outlet after 10 min (3.2 atm) for machine oil and after 20 min (6.4 atm) for paraffin and transformer oils, and water first appeared after 35 min (11.2 atm) in all three experiments. At the end of displacement (110 min, 35.2 atm), 199 mL of oil and 340 mL of water were produced for machine oil (ηoil = 47.38%, ηw = 42.50%), 184 mL of oil and 400 mL of water for paraffin oil (ηoil = 42.30%, ηw = 50.00%), and 165 mL of oil and 435 mL of water for transformer oil (ηoil = 37.08%, ηw = 54.38%). Machine oil thus showed the highest oil displacement and the lowest water production, and transformer oil the lowest oil displacement and the highest water production (Figure 5a,b).
During the first 60 min, the resistance changed only slightly for all oils (Figure 5c), indicating a relatively weak interaction with the rock during this period. After about 1 h, the resistance changed noticeably. For paraffin oil, the resistance decreased from 190 kΩ at the start to 120 kΩ at 85 min and 110 kΩ at the end; for transformer oil, it decreased gradually from 170 kΩ to about 100 kΩ; and for machine oil, it decreased from 140 kΩ to 80–100 kΩ, with smaller variations. The potential difference was highest for paraffin oil (78.6 mV initially and 60.4 mV at the end), intermediate for transformer oil (70.6 to 52.9 mV) and lowest for machine oil (57.8 to 42.4 mV) (Figure 5d).
The flow rate of each oil as a function of pressure during displacement indicated viscoplastic behaviour of all three oils inside the porous medium: the oil flow rate remained very low up to about 14 atm and increased sharply above 16 atm. In contrast, under normal conditions outside the porous medium, the flow rates of the oils increased with pressure in the manner of viscous liquids, and water behaved as a Newtonian liquid (Table 4).
4.3. Water Displacement of Oils with Magnetically Treated Water
The oil and water displacement coefficients obtained with untreated and magnetically treated water are shown in Figure 6 as functions of pressure, and the final values are summarised in Table 5 and Figure 7.
For all three oils, the oil displacement coefficient increased with pressure, and magnetic treatment gave higher final oil displacement than untreated water (Figure 6a–c). For paraffin and transformer oils, the oil displacement coefficient with treated water exceeded the untreated values from 6.4 atm onwards. For machine oil, the treated-water values were mostly below or close to the untreated values up to 25.6 atm and exceeded them at all intensities from 28.8 atm onwards. The highest final oil displacement coefficient was obtained at 125 mT for all three oils: 60.64% for machine oil, 54.32% for paraffin oil and 50.36% for transformer oil, compared with 47.38%, 42.30% and 37.08%, respectively, without the field. At 140 and 150 mT, the final oil displacement coefficient was lower than at 125 mT but remained higher than without the field (Table 5).
Magnetic treatment reduced water production (Figure 6d–f). For machine oil, water first appeared at the outlet at 12.8 atm without the field, but only at 22.4 atm with treated water at all intensities. For paraffin and transformer oils, water first appeared at 12.8 atm in all cases, but the water displacement coefficient at high pressures was lower with treated water. The final water displacement coefficient was lowest at 125 mT for all three oils: 30.00% for machine oil, 40.00% for paraffin oil and 44.75% for transformer oil, compared with 42.50%, 50.00% and 54.38% without the field. At higher intensities, water production increased again (Table 5, Figure 7b).
Magnetic treatment also changed the electrokinetic response of the medium during displacement. Without the field, the resistance and potential difference fluctuated and decreased during the experiments: from 120 to 90 kΩ and from 52.2 to 42.4 mV for machine oil, from 180 to 110 kΩ and from 73.2 to 60.4 mV for paraffin oil, and from 160 to 100 kΩ and from 67.8 to 52.9 mV for transformer oil. With magnetically treated water, these parameters remained nearly constant at all intensities: 90–100 kΩ and 42.1–44.1 mV for machine oil, 110–120 kΩ and 50.1–53.7 mV for paraffin oil, and 120–130 kΩ and 57.3–61.1 mV for transformer oil.
5. Discussion
5.1. Effect of Pressure and Magnetic Field on Water Flow
The non-linear dependence of the potential difference and resistance on pressure in the untreated case (Figure 4a,b) can be attributed to the complex response of electrokinetic processes in the porous medium to pressure. Initially, increasing pressure facilitated the penetration of water into the porous structure, ion transport became more ordered and the electrokinetic potential decreased, so that the flow of water and ions stabilised as the resistance decreased. With further increases in pressure, electrostatic interactions with the pore walls became stronger, which may explain the renewed increase in potential; the non-uniform distribution of ion concentration in the pore structure may also contribute. The decrease in outflow rate above 20.8 atm (Figure 4c) is consistent with a progressive reduction in the transmissibility of the medium at higher pressures, for example by compaction of the clay-bearing medium or reorganisation of the conductive pathways after contact with water.
The lower potential difference and resistance obtained with magnetically treated water are explained by the interaction of the magnetic field with the charged particles and ions in the water. By acting on ion motion, the field can increase ion mobility or redistribute ions, thereby changing the electrochemical properties of the liquid [14]. The occurrence of all minima at about 20.8 atm suggests that, at this pressure, the pressure-induced changes in the system reach a saturation point and that the combined effects of pressure and magnetic field produce a dynamic equilibrium in which the electrochemical properties of the fluid stabilise. The fact that the resistance under magnetic treatment remained below the untreated values above 20.8 atm indicates that magnetic treatment reduced the effect of pressure-related compaction or reorganisation on the conductive properties of the medium.
The most effective intensity depended on the parameter considered: the lowest potential difference and resistance were obtained at 125 mT, the highest outflow rate up to 20.8 atm at 150 mT, and the highest outflow rate at 27.2–30.4 atm at 107 mT. The water flow experiments therefore show that the magnetic effect is pressure-dependent and does not increase monotonically with intensity at all pressures.
5.2. Effect of Oil Properties on Displacement
The oil with the highest viscosity (transformer oil, 198 mm²/s) showed the lowest oil displacement and the highest water production, which is consistent with the strong influence of viscosity on displacement in porous media. However, machine oil (47.49 mm²/s) was displaced more effectively than paraffin oil, which had the lowest viscosity (24.9 mm²/s). Viscosity alone therefore does not determine the ranking; density and the physicochemical interaction of each oil with the sand–clay rock also affect its displacement and electrokinetic behaviour. The higher and more strongly varying potential difference and resistance recorded for paraffin oil indicate lower electrokinetic stability, whereas machine oil showed the lowest and most stable values (Figure 5c,d). The viscoplastic behaviour of all three oils inside the porous medium, in contrast to their viscous behaviour under normal conditions (Table 4), confirms that the interaction of the oils with the porous medium changes their flow behaviour. The adsorption of oil components and the hydration layers formed on the negatively charged clay surfaces are likely contributors to this interaction.
5.3. Effect of Magnetic Treatment on Oil Displacement
The consistent increase in the oil displacement coefficient and decrease in the water displacement coefficient with treated water (Table 5) indicate that magnetic treatment improved the net displacement of oil by water for all three oils. The effect increased with field intensity up to 125 mT and decreased at 140 and 150 mT, which suggests that above an optimal intensity the structural changes in the water reach saturation or that an opposite effect arises. This is consistent with earlier observations that the effectiveness of magnetic treatment depends on the correct choice of field intensity [14].
Several mechanisms proposed in the literature may contribute to the observed effect. After magnetic treatment, a number of physicochemical effects arise in heterogeneous water systems: scale formation decreases, the coagulation rate of suspended solids increases, the wetting ability of surfaces changes, and the dissolution of solids, particularly salts, is intensified [14]. Consistent with this, the water analysis showed lower hardness, calcium, magnesium and turbidity after magnetic treatment (Table 1), which can be explained by the separation of hardness ions as precipitate and by flocculation of colloidal particles; the total dissolved solids, however, increased slightly (from 759 to 767 mg/L). Weakly conducting water systems are diamagnetic and only weakly sensitive to magnetic fields, but they are sensitive to electric fields: an electric field arises in water moving through a magnetic field, which orients molecular dipoles and aggregates and activates the water [14]. Because the activity of the water does not disappear immediately after it leaves the field, a relaxation time exists, which depends on the field strength [14]. Within the framework of Equation (7), the magnetic term modifies the effective flow resistance of the medium, which provides a qualitative basis for the observed increase in filtration and displacement.
The stabilisation of the resistance and potential difference during displacement with treated water indicates that the magnetic field moderated the electrokinetic fluctuations that occurred in the untreated case. The improved displacement of oil was also accompanied by a delay in water breakthrough for machine oil (from 12.8 to 22.4 atm). For machine oil, the lower or similar oil displacement at low pressures with treated water shows that the beneficial effect became evident only at higher pressures.
5.4. Limitations
The results should be interpreted within the following limitations. The experiments used refined model oils and tap water at laboratory conditions rather than crude oil and formation brine at reservoir pressure and temperature. A single porous-medium composition (75% sand, 25% clay) was used, and each field intensity was tested in a separate experiment; replicate runs and measurement uncertainties are not reported. The interfacial tension, contact angle and zeta potential were not measured, so the mechanisms discussed in Section 5.3 are not directly verified. The generalised filtration law (Equation (7)) was not fitted to the experimental data. Further work should address these aspects, as well as the long-term effects of magnetic treatment and its interaction with different fluid compositions and geological conditions.
6. Conclusions
- A constant transverse magnetic field of 40–150 mT applied to injection water reduced the potential difference and electrical resistance of a water-saturated sand–clay porous medium and increased the water outflow rate at pressures of 1.6–30.4 atm. The minima of potential difference and resistance occurred at 20.8 atm for all conditions, with the lowest values at 125 mT (20.2 mV and 40.3 kΩ, compared with 45.4 mV and 74.6 kΩ without the field).
- Without magnetic treatment, the final oil displacement coefficient was 47.38% for machine oil, 42.30% for paraffin oil and 37.08% for transformer oil, with water displacement coefficients of 42.50%, 50.00% and 54.38%, respectively. All three oils showed viscoplastic behaviour inside the porous medium and viscous behaviour under normal conditions.
- Displacement with magnetically treated water increased the oil displacement coefficient and decreased the water displacement coefficient for all three oils. The most effective intensity was 125 mT, at which the final oil displacement coefficient reached 60.64% (machine oil), 54.32% (paraffin oil) and 50.36% (transformer oil), and the water displacement coefficient decreased to 30.00%, 40.00% and 44.75%, respectively. Above 125 mT, the effect decreased.
- Magnetic treatment stabilised the resistance and potential difference of the porous medium during displacement, which fluctuated in the absence of the field.
- A generalised filtration law including electric and magnetic forces was presented; it reduces to Darcy’s law in the absence of these forces.
- Geomagnetic activity should be monitored during laboratory experiments involving magnetic fields to ensure the reliability of the results.
Author Contributions
Conceptualization, methodology, investigation, formal analysis, writing—original draft preparation, writing—review and editing, supervision, E.A. All authors have read and agreed to the published version of the manuscript.
Funding
This research was funded by Azerbaijan State Oil and Industry University through the internal grant under Contract No. ED-15/2025.
Data Availability Statement
The original contributions presented in this study are included in the article. Further inquiries can be directed to the corresponding author.
Conflicts of Interest
The authors declare no conflicts of interest.
References
- Sheng, J. Enhanced Oil Recovery Field Case Studies; Gulf Professional Publishing: Oxford, UK, 2013.
- Blunt, M.J. Multiphase Flow in Permeable Media: A Pore-Scale Perspective; Cambridge University Press: Cambridge, UK, 2017.
- Koottungal, L. 2014 Worldwide EOR survey. Oil Gas J. 2014, 112, 79–91.
- Sheng, J.J.; Leonhardt, B.; Azri, N. Status of polymer-flooding technology. J. Can. Pet. Technol. 2015, 54, 116–126.
- Sheng, J.J. Status of surfactant EOR technology. Petroleum 2015, 1, 97–105.
- Raffa, P.; Broekhuis, A.A.; Picchioni, F. Polymeric surfactants for enhanced oil recovery: A review. J. Pet. Sci. Eng. 2016, 145, 723–733.
- Safarov, F.E.; Lobanova, S.Y.; Elubaev, B.U.; et al. Effective methods of enhanced oil recovery in fields with high-viscosity oil: Technologies of cyclic gel-polymer flooding and ASP treatment. Vestn. Neftegaz. Otrasli Kazakhstana 2021, 3, 61–74. (In Russian).
- Santos, R.; Loh, W.; Bannwart, A.; et al. An overview of heavy oil properties and its recovery and transportation methods. Braz. J. Chem. Eng. 2014, 31, 571–590.
- Kang, W.L.; Zhou, B.; Issakhov, M.; et al. Advances in enhanced oil recovery technologies for low permeability reservoirs. Pet. Sci. 2022, 19, 1622–1640.
- Abbasov, A.A. Monitoring and determination of the efficiency of waterflooding on the basis of the capacitance–resistance model. Azerb. Oil Ind. 2019, 6–7, 33–37. (In Azerbaijani).
- Kerimov, N.S. Current state of waterflooding of production objects of the Neft Dashlari field and optimization of the waterflooding system. Azerb. Oil Ind. 2015, 6, 19–25. (In Azerbaijani).
- Asadollahi, M. Waterflooding Optimization for Improved Reservoir Management. Ph.D. Thesis, Norwegian University of Science and Technology (NTNU), Trondheim, Norway, 2012.
- Bera, A.; Babadagli, T. Status of electromagnetic heating for enhanced heavy oil/bitumen recovery and future prospects: A review. Appl. Energy 2015, 151, 206–226.
- Mammadzade, A.M. Nanotechnological Foundations of the Application of Non-Equilibrium Effects of Physical Fields in Oil and Gas Production; Azerbaijan State Oil and Industry University: Baku, Azerbaijan, 2021. (In Azerbaijani).
- Mamedzade, A.M.; Alizade, E.F.; Melikov, T.G.; et al. Determination of the final oil recovery factor when treating water with an external constant transverse magnetic field of low intensity. Vestn. KazUTB 2025, 26, 452–463. (In Russian).
- Mirzajanzade, A.Kh.; et al. Exploitation and Development of Oil and Gas Fields; Azerneftneshr: Baku, Azerbaijan, 1960. (In Azerbaijani).
- Mirzajanzade, A.; Ahmadov, Z.; Gurbanov, R. Physics of the Oil Reservoir; Maarif: Baku, Azerbaijan, 1983. (In Azerbaijani).
- Alizade, E.F. Comprehensive experimental analysis of electromagnetic field effects on enhanced oil recovery through optimized magnetic field-induced fluid dynamics. Kazakhstan J. Oil Gas Ind. 2025, 7, 41–51.
- Alizade, E.F. Investigation of magnetic field effects on fluid mobility and enhanced oil recovery optimization. J. Adv. Eng. Forum 2025, 57, 39–50.
- Mammad-zade, A.M.; Alizade, E.F. Investigation of fluid dynamics impact with magnetic field applications on enhanced oil recovery in porous media. SOCAR Proc. 2025, 2, 61–67.
- Mammad-zade, A.M.; Aliyev, E.N.; Alizade, E.F.; et al. Pore-scale evaluation of oil samples with distinct physicochemical properties for enhanced oil recovery efficiency. Proc. Sci.-Res. Inst. Geotechnol. Probl. Oil Gas Chem. 2025, 25, 68–80.
- Mammad-zade, A.M.; Aliyev, E.N.; Alizade, E.F.; et al. The effect of electrokinetic phenomena on the flow of reservoir fluids in a porous medium. Proc. Sci.-Res. Inst. Geotechnol. Probl. Oil Gas Chem. 2024, 24, 5–16.
- Alizade, E.F. Investigation of changes in electrokinetic and rheological properties during the displacement of oils under the effect of a magnetic field. In Proceedings of the II Republican Scientific Conference of Young Researchers “Scientific Development: Successes and Challenges”, Nakhchivan, Azerbaijan, 3–4 April 2025; pp. 806–811. (In Azerbaijani).
- Alizade, E.F. Investigation of the effect of displacement of oils with different physicochemical properties in a porous medium on enhanced oil recovery. In Proceedings of the XII International Eurasian Congress of Applied Sciences, Mingachevir, Azerbaijan, 17–18 February 2025; pp. 345–355. (In Azerbaijani).
- Alizade, E.F. Investigation of the displacement dynamics of oils of different viscosity in a porous medium. In Proceedings of the VIII Republican Scientific Conference of Young Researchers, Baku, Azerbaijan, 14 March 2025; pp. 122–125. (In Azerbaijani).
- Das, M.K.; Mukherjee, P.P.; Muralidhar, K. Modeling Transport Phenomena in Porous Media with Applications; Springer: Berlin, Germany, 2018.
- Alizade, E.F. Investigation of injection pressure optimization effect in oil production on the permeability of the reservoir rock. Proc. Azerb. High Tech. Educ. Inst. 2025, 27, 14–20.
- Suleymanov, A.A.; Mammad-zade, A.M.; Melikov, H.K.; Aliyev, E.N.; et al. Device for Magnetic Treatment of Water Injected into Oil Reservoirs. Utility Model F 2025 0029, Republic of Azerbaijan, 2025.
- Magnetic Storms in Baku. Available online: https://time-in.ru/magnitnye-buri/baku (accessed on 10.08.2026). (In Russian).
- Mamedzade, A.M.; Nazarov, F.B.; Alizade, E.F.; et al. Effect of a magnetic storm caused by a solar flare on magnetic field measurements of a system on the Earth. Caucasus Econ. Soc. Anal. J. South. Caucasus 2024, 2, 81–86. (In Russian).
- Mammad-zade, A.M.; Alizade, E.F. Influence of solar flare-generated magnetic storms on geomagnetic field measurements and their implications for the petroleum industry. In Proceedings of the Meetcon-Europe International Congress on Scientific Research, Munich, Germany, 13–17 October 2025; pp. 5–10.
- Alizade, E.F.; Mammadzade, A.M. Geomagnetic variability effects on reservoir-scale magnetic investigations. In Proceedings of the 3rd International Yeditepe Scientific Research Congress, Istanbul, Türkiye, 11–12 October 2025; pp. 136–143.
Figure 1.
Schematic diagram of the experimental setup for displacement with magnetically treated water: 1—УСА-4А regulator; 2—SUNTEK 2000 VA voltage regulator; 3—volt-ammeter; 4—electromagnet; 5—measuring cylinder; 6, 10, 13, 15, 17—valves; 7, 9, 16—pressure gauges; 8—high-pressure column; 11—URV-2M potentiometer; 12—thermostat; 14—PVT-type high-pressure bomb; 18—liquid tank; 19—measuring press.
Figure 1.
Schematic diagram of the experimental setup for displacement with magnetically treated water: 1—УСА-4А regulator; 2—SUNTEK 2000 VA voltage regulator; 3—volt-ammeter; 4—electromagnet; 5—measuring cylinder; 6, 10, 13, 15, 17—valves; 7, 9, 16—pressure gauges; 8—high-pressure column; 11—URV-2M potentiometer; 12—thermostat; 14—PVT-type high-pressure bomb; 18—liquid tank; 19—measuring press.

Figure 2.
Photograph of the experimental setup.

Figure 3.
Schematic of the magnetic treatment device: 1—copper tube carrying the liquid; 2—electromagnet core; 3—copper windings; 4—step-down transformer; 5—voltage regulator.
Figure 3.
Schematic of the magnetic treatment device: 1—copper tube carrying the liquid; 2—electromagnet core; 3—copper windings; 4—step-down transformer; 5—voltage regulator.

Figure 4.
Effect of pressure and magnetic field intensity on water flow through the porous medium: (a) potential difference; (b) electrical resistance; (c) water outflow rate.
Figure 4.
Effect of pressure and magnetic field intensity on water flow through the porous medium: (a) potential difference; (b) electrical resistance; (c) water outflow rate.

Figure 5.
Displacement of the three oils by untreated water as a function of time (pressure increased by 1.6 atm every 5 min from 1.6 to 35.2 atm): (a) oil displacement coefficient; (b) water displacement coefficient; (c) electrical resistance; (d) potential difference.
Figure 5.
Displacement of the three oils by untreated water as a function of time (pressure increased by 1.6 atm every 5 min from 1.6 to 35.2 atm): (a) oil displacement coefficient; (b) water displacement coefficient; (c) electrical resistance; (d) potential difference.

Figure 6.
Oil displacement coefficient (a–c) and water displacement coefficient (d–f) as functions of pressure for displacement with untreated water and water treated at 40–150 mT: (a,d) machine oil; (b,e) paraffin oil; (c,f) transformer oil.
Figure 6.
Oil displacement coefficient (a–c) and water displacement coefficient (d–f) as functions of pressure for displacement with untreated water and water treated at 40–150 mT: (a,d) machine oil; (b,e) paraffin oil; (c,f) transformer oil.

Figure 7.
Final displacement coefficients at 35.2 atm as functions of magnetic field intensity (0 = untreated water; categories are evenly spaced): (a) oil displacement coefficient; (b) water displacement coefficient.
Figure 7.
Final displacement coefficients at 35.2 atm as functions of magnetic field intensity (0 = untreated water; categories are evenly spaced): (a) oil displacement coefficient; (b) water displacement coefficient.

Table 1.
Physicochemical properties of the tap water before and after magnetic treatment.
| Parameter | Before magnetic treatment | After magnetic treatment |
| pH | 7.3 | 7.1 |
| Total dissolved solids, mg/L | 759 | 767 |
| Hardness, mg/L | 241 | 232 |
| Alkalinity, mg/L | 175 | 171 |
| Turbidity | 0.56 | 0.4 |
| Chloride (Cl), mg/L | <0.02 | <0.02 |
| Calcium (Ca), mg/L | 30 | 27.5 |
| Magnesium (Mg), mg/L | 41 | 36 |
| Iron (Fe), mg/L | <0.01 | 0.008 |
| Manganese (Mn), mg/L | <0.005 | 0.004 |
Table 2.
Properties of the oils used in the experiments.
| Property | Machine oil | Paraffin oil | Transformer oil |
| Density at 20 °C, kg/m³ | 850 | 840 | 971 |
| Kinematic viscosity, mm²/s | 47.49 | 24.9 | 198 |
| Coking value, % | 0.49 | 0.46 | 0.55 |
| Acid number, mg KOH/g | 0.038 | 0.037 | 0.035 |
| Ash content, % (mass) | 0.008 | 0.007 | 0.026 |
| Water-soluble acids and alkalis | None | None | None |
| Mechanical impurities, % (mass) | 0.013 | 0.017 | 0.040 |
| Flash point (open cup), °C | 260 | 275 | 290 |
| Water content, % | 0.03 | 0.05 | 0.08 |
| Pour point, °C | −8 | −8 | −10 |
| Sulphur content, % (mass) | 0.2 | 0.1 | 0.5 |
Table 3.
Calibration of the magnetic field intensity against the regulator voltage.
| Regulator voltage U, V | 5 | 10 | 15 | 20 | 25 | 30 |
| Magnetic field intensity H, mT | 40 | 80 | 107 | 125 | 140 | 150 |
Table 4.
Flow rates of water and oils under normal conditions (outside the porous medium).
| Time, min | Pressure, atm | Water, cm³/min | Machine oil, cm³/min | Paraffin oil, cm³/min | Transformer oil, cm³/min |
| 2 | 0.5 | 0.00 | 0.00 | 0.00 | 0.00 |
| 4 | 1.0 | 8.00 | 6.50 | 4.50 | 2.50 |
| 6 | 1.5 | 15.75 | 13.75 | 10.75 | 7.50 |
| 8 | 2.0 | 23.33 | 21.67 | 18.33 | 15.00 |
Table 5.
Final oil and water displacement coefficients (%) at 35.2 atm for displacement with untreated and magnetically treated water.
Table 5.
Final oil and water displacement coefficients (%) at 35.2 atm for displacement with untreated and magnetically treated water.
| Oil | No field | 40 mT | 80 mT | 107 mT | 125 mT | 140 mT | 150 mT | |
| Machine oil | ηoil | 47.38 | 51.46 | 54.34 | 57.89 | 60.64 | 59.74 | 56.15 |
| ηw | 42.50 | 38.75 | 36.25 | 32.50 | 30.00 | 31.25 | 33.75 | |
| Paraffin oil | ηoil | 42.30 | 46.35 | 48.09 | 50.73 | 54.32 | 52.68 | 51.19 |
| ηw | 50.00 | 48.75 | 45.38 | 42.50 | 40.00 | 41.88 | 44.38 | |
| Transformer oil | ηoil | 37.08 | 40.91 | 42.79 | 46.12 | 50.36 | 48.33 | 47.06 |
| ηw | 54.38 | 51.25 | 48.75 | 46.88 | 44.75 | 45.63 | 47.50 |
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |