Abstract
Optical fiber sensors have experienced remarkable development due to their advantages in sensitivity, immunity to electromagnetic interference, compact size, and remote monitoring capability. Among them, devices operating in the visible spectral region have gained particular attention because of their low cost, ease of implementation, and potential for biomedical, chemical, and environmental applications. This review presents the fundamentals and recent advances in visible-light-based optical fiber sensors, covering the main interferometric configurations, including Michelson, Mach–Zehnder, Fabry–Pérot, and Sagnac interferometers. In addition, different sensing platforms, such as single-mode, multimode, plastic, and photonic optical fibers, are analyzed, highlighting their characteristics and advantages for specific applications. Various sensing mechanisms are reviewed, including optical absorption, fluorescence, surface plasmon resonance, and evanescent field sensing. Furthermore, applications focused on the measurement of pH, glucose, pressure, humidity, and other parameters of biomedical and environmental interest are discussed. The studies analyzed demonstrate that the combination of optical fibers with functional materials and spectroscopic techniques in the visible region enables the development of highly sensitive, selective, and real-time monitoring sensors. Finally, the current challenges and future perspectives of this technology for scientific and industrial applications are presented.
Keywords: 
;  ;  ;  ;  ;  ;  ;  

1. Introduction

In today’s technological era, sensors play a fundamental role in detecting and quantifying physical or chemical quantities in a range of environments (1). They include everything from basic devices, such as light (2-5) or temperature detectors (6-10), to sophisticated biometric units capable of integrating multiple parameters in advanced applications (11-14). This versatility is reflected in their use in industry (15), medicine (16-20) and the environment (5, 6, 9, 10, 22), transforming physical quantities into meaningful data for the efficient monitoring and control of processes. The growing importance of sensors is driving the ongoing search for improvements in the accuracy and efficiency of real-time data collection (23).
Within this landscape, fibre-optic sensors stand out as a significant innovation in detection and measurement (24). Using optical fibres as a transmission medium, they harness the unique properties of light to detect variations in physical (18–21) or chemical (22–24) quantities. Optical fibres consist of a glass or plastic core surrounded by a cladding that reflects light and enables it to propagate through total internal reflection (25). These sensors offer advantages such as immunity to electromagnetic interference and the ability to monitor hard-to-reach areas, thereby improving accuracy and efficiency in identifying key variables across different contexts (26). Fibre-optic sensors operate across different regions of the light spectrum, and studies have been reported in the IR (27–31), NIR (32, 33), UV (34–37) and VIS (38–40) ranges.
The visible spectrum (VIS) is particularly relevant to the development of fibre-optic sensors, as it enables the use of widely available, low-cost light sources such as LEDs and solid-state lasers, while also facilitating integration with conventional optical systems (41–43). The use of visible light offers practical advantages in biomedical and environmental applications, where interaction with transparent or semi-transparent materials enables precise detection without the need for specialised high-power equipment. In addition, compatibility with imaging and spectroscopy techniques in the visible range broadens the potential of these sensors for real-time monitoring of physical and chemical parameters (44), consolidating their role as versatile and accessible tools in today’s technological landscape (45).

2. Materials and Methods

Optical interferometry is based on the wave nature of light, in which electromagnetic waves can superpose to produce interference patterns (46). According to the principle of superposition, when two or more coherent waves combine, the result is a wave whose amplitude is the vector sum of the individual amplitudes. This can lead to constructive interference (an increase in intensity) or destructive interference (a decrease or cancellation of intensity) (46). As shown in Figure 1: (D) direction of propagation; (A) resultant amplitude ( A W + A W 1 = A R ); and (C) direction of vibration.
For interference to occur, the waves must be coherent; that is, they must maintain a constant phase difference over time and space (47). The optical path difference (OPD) between the waves determines the type of interference: if it is an integer multiple of the wavelength (λ), the interference is constructive; if it is an odd multiple, it is destructive (48,49). These principles are applied in interferometers to measure minute displacements, changes in refractive index or rotations with high sensitivity (50). In the context of optical fibres, light propagates through single-mode, multimode and plastic fibres, where phenomena such as dispersion and attenuation must be taken into account to maintain coherence (51).

2.1. Types of fibre-optic interferometers

Fibre-optic interferometers are widely used in sensing applications because of their high sensitivity. The most commonly used configurations include Michelson, Mach-Zehnder, Fabry-Pérot and Sagnac interferometers (52). Although they all operate by splitting and recombining light beams to produce interference, their structural characteristics make them suitable for different measurement scenarios (53).

2.1.1. Michelson interferometer

The fibre-optic Michelson interferometer is an implementation of the classical interferometric scheme in a guided-wave medium. As shown in Figure 2 (61), the light beam from the laser, with an input power of P I N is split into two arms by a 3 dB coupler, usually with a 50:50 split ratio (59). One arm acts as the reference, while the other is the sensing arm (60).
In the sensing arm, of length L S , the light propagates through an optical coil (sensing element), which acts as the element sensitive to the quantity being measured, and is then reflected by a mirror, usually a Faraday mirror or a reflector at the end of the fibre (61). In the reference arm, of length L R , the light travels through a similar optical coil, controlled by a piezoelectric actuator that allows the optical length of this branch to be finely adjusted, and is also reflected by a mirror (61).
The reflected beams return to the 3 dB coupler, where they recombine to generate an interferometric signal that is directed to the photodetector and recorded as the output powe P O U T . The phase difference between the two arms depends on the discrepancy in the optical path lengths. When an external perturbation, such as pressure, strain or temperature, changes the optical path length of the sensing arm, it causes a phase shift that alters the recorded intensity (61). The phase difference is expressed as follows:
Δ ϕ = 4 π n e f λ L S − L R 1
where n e f is the effective refractive index of the optical fibre, λ is the wavelength of the light source, L S represents the length of the sensing arm and L R the length of the reference arm. The output power depends directly on this phase difference and can be written as:
P O U T = P I N 2 1 + c o s Δ ϕ 2
where P I N represents the average power of the input signal.

2.1.2. Mach-Zehnder Interferometer

In this configuration, known as a fibre-optic Mach-Zehnder interferometer and shown in Figure 3 (59), the laser beam is split into two parallel paths by a first 3 dB coupler (generally 50:50). The light then travels along two separate optical fibres: a reference arm, which remains stable and is not intentionally altered, and a sensing arm, in which the fibre is exposed or designed to be affected by the quantity to be measured.
Both arms terminate at a second 3 dB coupler, where the beams are recombined. The resulting interference depends on the variations introduced in the sensing arm, whether due to changes in the fibre’s optical path length or its refractive index (59). This configuration is widely used in phase sensors, which can detect environmental variations such as temperature, strain, pressure or vibrations (60). The phase difference between the two arms is expressed as:
Δ ϕ = 2 π λ n S L S − n R L R
where n S and n R are the effective refractive indices, and L S and L R represent the lengths of the sensor and reference arms. The output intensity is given by:
I = I 1 + I 2 + 2 I 1 I 2 c o s Δ ϕ ( 4 )
where I 1 and I 2 correspond to the optical intensities of each arm.

2.1.3. Fabry-Perot Interferometer

In this interferometer, illustrated in Figure 4 (62), a resonant cavity is formed between two reflective surfaces in the fibre, such as cleaved ends or Bragg gratings (53). It can be intrinsic (within the fibre) or extrinsic (with an air cavity) (55).
The multiple interference generated within the cavity produces a well-defined fringe spectrum that is highly sensitive to changes in its length. This makes the configuration particularly suitable for pressure and temperature sensing. When the cavity length changes due to external perturbations such as pressure, strain or temperature, the resonance condition changes and the interference pattern shifts. The phase difference between successive reflections is expressed as follows:
Δ ϕ = 4 π n L λ
where L represents the cavity length, n is the effective refractive index of the medium inside the cavity, and λ corresponds to the wavelength of the light source. The transmitted intensity can be described by the Airy equation:
I t = I 0 ⋅ 1 1 + F s i n 2 Δ ϕ 2
where I 0 represents the incident optical intensity, F = 4 R 1 − R 2 is the cavity finesse coefficient, and R corresponds to the reflectivity of the reflecting surfaces.

2.1.4. Sagnac Interferometer

Based on a fibre loop, as shown in Figure 5 (59), in which the light is split and travels in opposite directions (clockwise and anticlockwise), recombining at the point of origin (56). Rotation induces a non-reciprocal phase difference (the Sagnac effect), making this type ideal for optical gyroscopes and rotation sensors (53). It requires no mirrors, making it robust for inertial applications.
When the system undergoes angular rotation, a difference arises in the propagation time of the two beams, a phenomenon known as the Sagnac effect. This effect produces a non-reciprocal phase difference that is readily detectable in the output signal. As it does not require mirrors, this configuration is particularly robust and is widely used in optical gyroscopes and rotation sensors for inertial applications (53). The phase difference induced by rotation is expressed as:
Δ ϕ = 8 π A Ω λ c
where start equation cap A represents the area enclosed by the fibre-optic loop, start equation cap omega is the angular velocity of rotation, start equation c is the speed of light in a vacuum, and start equation lambda is the operating wavelength. The output intensity is described by:
I = I 0 1 + c o s ( Δ ϕ )
where I 0 corresponds to the average signal intensity.

2.2. Surface Plasmon Resonance (SPR) Sensors

Surface Plasmon Resonance (SPR) sensors are based on the interaction between light and the free electrons in a metal layer, usually gold. When the resonance condition is met, the light’s energy is transferred to the surface plasmons, resulting in a decrease in the detected optical intensity (57).
The resonance condition occurs when the propagation constant of the surface plasmon matches the tangential component of the incident wave vector (58):
k s p ​ = k x ​
where kₛₚ is the propagation constant of the surface plasmon and kₓ is the tangential component of the incident wave. The propagation constant of the surface plasmon is expressed as:
k s p ​ = 2 π λ ε m ε d ε m + ε d
where λ is the operating wavelength, ε m is the dielectric permittivity of the metal and ε d is the permittivity of the medium under analysis. SPR sensors are highly sensitive to variations in the refractive index near the metal surface. Their sensitivity can be defined as follows:
S = ∆ λ r e s ∆ n
where S is the sensor sensitivity, Δ λ r e s is the shift in the resonance wavelength, and ∆ n is the change in the refractive index of the medium. Owing to this characteristic, SPR sensors have applications in chemical detection, environmental monitoring and biosensing (59).

3. Sensors

3.1. Photonic Optical Fibre

Photonic crystal fibre is characterised by a periodic photonic-crystal structure in its core or cladding, which makes it possible to manipulate light propagation by creating photonic band gaps (60,61). This design enables precise control of dispersion, modal confinement and group velocity, offering substantial advantages over conventional fibres (62). Thanks to its ability to guide light even through hollow cores and to tune its properties through the geometry of the microstructure.
Thanks to these characteristics, photonic crystal fibres have been widely investigated for sensing physical, chemical and biological parameters (63). Their microstructured design promotes greater interaction between the optical field and the external medium, enabling higher sensitivities than those achieved with conventional fibres (63).
In this context, in 2016 Hafeez developed an optical fibre sensor with a 35 mm-long CPC tip, as shown in Figure 6 (65), which markedly improved fluorescence collection. This advance resulted in an average increase of 1.7-fold compared with standard flat-tip sensors. As detailed in the figure, the design comprises (a) the physical structure of the sensor, showing the optical fibre connected to the sensor head and the length of the compartment coated with a permeable membrane; (b) the FRET-based detection mechanism (Förster resonance energy transfer) under low and high glucose concentrations, illustrating the interaction between the fluorophore-labelled protein, the glucose analogue and the reference dye; and (c) the emission intensity spectrum as a function of wavelength, comparing the responses at concentrations of 40 mg/dL and 400 mg/dL. It is important to note that, up to that point, neither silica-fibre nor POF-based glucose sensors with optimised tip geometry had been used (65).
In 2019, Ayyanar proposed an innovative device for monitoring blood glucose levels using a trinuclear photonic glass fibre. In this device, a hollow channel filled with the sample of interest acts as the liquid core, accompanied by two additional cores. The silicon substrate was shown to have a notable sensitivity of 23,267.3 nm/RIU. Analysis of the transmission spectrum identified a maximum wavelength shift for polarisation at 470 and 440 nm (66).

3.2. Single-Mode Optical Fibre

Single-mode optical fibre is characterised by its small-diameter core, typically between 8 and 10 μm, which allows only the fundamental mode of light to propagate (67). This property eliminates modal dispersion and significantly reduces transmission losses, enabling optical signals to propagate over long distances with high stability and broad bandwidth (68). In addition, its high sensitivity to environmental variations and compatibility with various sensing configurations make it one of the most widely used platforms in the development of fibre-optic sensors.
Thanks to these characteristics, single-mode fibres have been widely used to detect physical, chemical and biological parameters (68). Their ability to modify the phase, intensity, wavelength or polarisation state of light in response to external stimuli enables the design of highly precise sensors for measuring temperature, strain, pressure, refractive index and biomolecules (68).
In 1993, Kopelman reported one of the first demonstrations of submicrometre- and nanometre-scale optical fibre-based pH sensors, fabricated using nanofabricated fibre tips combined with near-field photoinitiated polymerisation. By tapering conventional optical fibres to diameters below 0.1 μm and immobilising a fluorescein-containing acrylamide copolymer on the fibre core, the authors achieved unprecedented miniaturisation, producing sensors measuring 0.1–1 μm with ultrafast response times of less than 100 ms. The sensor also exhibited high fluorescence intensity, approximately 10⁶ cps, and could detect pH changes in extremely small volumes, corresponding to fewer than 3,000 H⁺ ions at pH 8, demonstrating its high detection capability in microvolumes. The sensor size was shown to be governed by the diameter of the optical core, confirming that polymer growth is confined to the near-field region of the emitted light. These sensors exhibited high fluorescence efficiency, good resistance to photobleaching and reliable pH measurements in confined microenvironments, including biological samples such as individual cells and embryos (69).
In 2010, Yunliang developed a single-mode optical fibre sensor coated with silicon and quartz, using gold as a dopant to achieve a sensitivity of 13.09 nm/RIU at a wavelength of 559.0 nm in the visible range, as shown in Figure 7 (39). The sensor was used to detect changes in the refractive index and in antibody assays, with specific sensitivities observed for different gold particle sizes (39).
In 2012, Breña introduced an innovative optical-fibre current sensor configuration based on the Faraday effect and the use of a Faraday mirror (OCR), designed to compensate for linear birefringence and improve the system’s sensitivity. The proposal was implemented in single-mode fibre using orthogonal polarisation conjugation with counter-propagating light, employing two 45° Faraday rotators and a 10 mW laser at 633 nm. The simulations included typical losses for connectors (0.3 dB), fibre (15 dB/km), NBS (3 dB) and OCR (2 dB). The results showed a linear response for polarisation rotations from −15° to +15°, with a measurement range of up to 50 kA and an accuracy of less than 0.2% (±2 kA), applicable to both direct and alternating current (70).
Figure 8. Diagram of the magneto-optical current sensor with linear birefringence suppression (70).
Figure 8. Diagram of the magneto-optical current sensor with linear birefringence suppression (70).
Preprints 240007 g008
In 2024, Lozano developed a low-coherence external Fabry–Perot interferometer (CLEFPI) using 630-HP fibre and a 200 µm capillary for temperature detection, as shown in Figure 9 (71). The devices achieved sensitivities of up to 5.77 nm/°C between 25 and 35 °C, with high linearity R² = 0.99; cumulative phase analysis extended the range to 41 °C. The sensor stands out for its low cost and potential applications in biomedicine and biotechnology (71).
In 2024, Jauregui proposed an optical fibre curvature sensor operating in the visible range, based on an all-fibre Mach–Zehnder interferometer (Figure 10) (72). The device was constructed using an in-line sandwich structure with fibres specifically designed for visible light (630HP and 460HP). A defective splice between fibres with different core diameters enabled the simultaneous excitation of core and cladding modes. Interference between these modes produced spectral modulation sensitive to the applied curvature. Experimentally, the sensor was characterised over the visible range from 460 nm to 630 nm, achieving a maximum sensitivity of −10.44 nm·m⁻¹, with high reproducibility and minimal hysteresis (72). The proposed experimental setup is shown in Figure 11 (72).
In 2024, Zongjie developed fibre-optic chemical pH sensors based on the surface modification of tapered optical fibres with carboxylated ZnCdSe/ZnS quantum dots (Figure 12) (73). The detection principle relies on changes in photoluminescence intensity as a function of pH, associated with the protonation and deprotonation of surface functional groups. The sensors showed a sensitivity of 0.139 pH⁻¹ over the pH range 6.00–9.01, a response time of less than 40 s and good stability, demonstrating their potential for rapid and accurate pH detection in chemical and environmental applications (73).
In 2025, Keyla developed a fibre-optic curvature detection system to monitor the angular position of the index finger of a robotic arm (Figure 13) (74). The sensor uses a standard single-mode optical fibre (630HP) in the visible spectrum, with its output signal processed using image analysis and machine-learning algorithms. Images of the output profile were analysed in the RGB, HSV and CIELab colour spaces, with green proving to be the most significant. The results showed that techniques such as Decision Tree achieved an accuracy of 58.33% across the full range (0°–85°), rising to 82.66% when the range was restricted (20°–65°). In addition, k-Nearest Neighbour combined with Neighbourhood Component Analysis achieved an accuracy of up to 92.88% in identifying angles between 0° and 85°. This approach, also validated using simulations in Ansys Lumerical, offers a versatile, low-cost alternative to traditional fibre-optic sensing techniques (74).

3.3. Multimode Optical Fibre

Multimode optical fibre is characterised by a larger core diameter, generally between 50 and 62.5 μm, which allows multiple modes of light to propagate simultaneously (67). This property facilitates the coupling of the optical signal and reduces the alignment requirements for the light source, making it well suited to short-range communication systems and various sensing applications. However, the coexistence of multiple optical paths causes modal dispersion, limiting the bandwidth and transmission distance compared with single-mode fibres (68).
Thanks to their ease of manufacture, low cost and large optical interaction area, multimode fibres have been widely used to detect physical, chemical and biological parameters (68). In particular, they have attracted considerable interest in the biomedical field because of their ability to be integrated into real-time diagnostic and monitoring devices. The distribution of multiple light paths within the core enables sensing configurations based on intensity, fluorescence, absorption and refractive index, making them attractive tools for environmental monitoring, chemical detection and biosensing applications (43). These include sensors designed to measure glucose, biomarkers and other clinically relevant analytes.
In 1987, Kawabata fabricated a fluorescence-based optical pH sensor using an indicator immobilised as a molecular monolayer on the end surface of an optical fibre. The sensor uses fluorescein isothiocyanate (FITC) covalently attached to the fibre tip, enabling rapid, reversible pH detection by monitoring fluorescence intensity at 520 nm. The device exhibits a reversible response over the pH range 4.0–6.9, with an accuracy of ±0.1 pH units. Thanks to its monolayer immobilisation, the sensor has an intrinsic response time of less than 10 ms, substantially outperforming conventional glass electrodes (75).
In 1992, Wolthuis presented a fibre-optic medical pH sensor based on the principle of optical absorption, designed specifically for physiological applications such as measuring blood pH. The sensor uses an absorbing colourimetric indicator with an absorption peak in the red region (625–630 nm), analysed using a pulsed LED and a ratiometric arrangement with a dichroic mirror, which improves stability against fluctuations in light intensity. The system showed an approximately linear response across the physiological pH range of 6.8–7.8, with a resolution and accuracy of around 0.01 pH units and response times of 30–40 s. Tests using heparinised human blood demonstrated excellent agreement with clinical analysers (76).
In 1997, Sotomayor developed a fibre-optic pH sensor using a pH-sensitive conducting polymer, poly(o-methoxyaniline) doped with p-toluenesulfonic acid, as the active phase (Figure 14) (77). The detection principle is based on measuring diffuse reflectance in the visible region, associated with colour changes in the polymer induced by protonation and deprotonation. Two optode configurations were evaluated, using different methods to immobilise the sensing material: entrapment in a polymer matrix and adsorption onto a polyethylene membrane. The sensors showed broad dynamic ranges (up to 8 pH units), good reversibility, accuracy of around 0.01 pH units, and response times of the order of minutes, demonstrating the potential of conducting polymers as active materials in fibre-optic pH sensors (77).
In 2006, Ganesh reported a fibre-optic pH sensor based on the principle of optical absorption, using pH indicators (Congo red and Neutral red) covalently immobilised on a cellulose acetate membrane. The sensor showed good reversibility, reproducibility and long-term stability, with response times of less than 20 s. Linear pH measurement ranges of 4.2–6.3 for Congo red and 4.1–9.0 for Neutral red were obtained, with the latter notable for its wide range (78).
In 2010, Sharma reported the fabrication and characterisation of an optical fibre pH sensor based on evanescent-field absorption, using the sol-gel technique to immobilise ethyl violet dye on the bare fibre core. The sensor exhibited an exceptionally broad operating range, covering pH values from 2 to 13 using a single dye, making it one of the widest ranges reported in the literature. The results showed that the sensor’s sensitivity increases with the length of the fibre’s active region. The sensor response was also found to depend significantly on the ionic strength and temperature of the medium, indicating that optimal performance is achieved under well-controlled measurement conditions (79).
In 2012, Sarika introduced an innovative optical fibre sensor that uses surface plasmon resonance (SPR) to detect low glucose levels in aqueous liquids. The sensor uses a probe made by coating the optical fibre core with layers of silver and silicon. It can measure glucose concentrations ranging from 0 to 260 mg/dL. Measurements using standard PMMA POF are carried out with a photon-counting OTDR device supplied by Sunrise Luciol, using a 650 nm light source in the visible spectrum (80).
In 2013, Mishra implemented an optical pH sensor based on surface plasmon resonance (SPR) and integrated into an optical fibre, using an unclad fibre core as the sensing platform. The device was functionalised with metallic and transparent conductive coatings, including silver, aluminium and ITO (In₂O₃:SnO₂), deposited by thermal evaporation, as well as a smart hydrogel layer prepared by dip coating. The detection principle is based on changes in the hydrogel’s refractive index caused by swelling and contraction in response to pH changes, which induce a spectral shift in the SPR resonance wavelength, observed through wavelength interrogation. In particular, h an increase in pH causes the hydrogel to swell, reducing its refractive index and producing a blue shift in the resonance in the transmitted spectra. It was also demonstrated that optimising the thickness of the ITO and aluminium layers significantly improves sensor performance: the ITO layer increases sensitivity, while the aluminium layer improves detection accuracy. The sensor achieved a sensitivity of over 12.5 nm/pH compared with other devices reported in the literature, and also showed low temperature dependence over the range of 25–45 °C (81).
In 2014, Raoufi developed a high-resolution optical pH sensor based on multimode optical fibre (Figure 15) (82), operating in the visible-light range using absorption spectroscopy. The device was fabricated on an unclad silica fibre, functionalised using the layer-by-layer technique with the indicator Brilliant Yellow and poly(allylamine hydrochloride). The detection principle is based on the spectral shift of the indicator’s absorption band, which has a maximum at around 497 nm, in response to changes in pH. The effects of the number of bilayers, indicator concentration, fibre geometry and core diameter were evaluated. The highest sensitivity, 148.7 nm/pH, was observed when low dye concentrations and highly curved U-shaped fibres were used (Figure 16) (82), increasing the interaction between the evanescent field and the sensing layer (82).
In 2014, Zhao proposed a pH optical fibre sensor based on CdSe/ZnS quantum dots (QDs) functionalised with carboxyl groups and immobilised on the tapered tip of a silica fibre by silanisation with APTES and activation with EDC/Sulfo-NHS. The sensor’s sensitivity was evaluated by measuring changes in photoluminescence (PL) intensity and shifts in the emission peak as a function of pH over a range of 3 to 11. The results showed a linear relationship between PL intensity and pH for all three types of QDs tested (green, yellow and red, with emission peaks at 530, 565 and 605 nm, respectively), accompanied by a slight red shift in the emission peak as pH increased: approximately 3 nm for the green and yellow QDs, and 4 nm for the red QDs, across the pH range studied. The red QDs exhibited the greatest sensitivity, defined as the steepest slope in the intensity–pH relationship, while the green QDs showed the best linearity, albeit with a shallower slope. This behaviour was attributed to the degree of ionisation of the carboxyl ligand: under alkaline conditions, deprotonation of the carboxyl groups promotes electron transfer from the negatively charged ligand to the QDs, increasing fluorescence intensity; under acidic conditions, the reverse process occurs, attenuating (quenching) the signal. These results demonstrate that the sensor sensitivity is 0.4–0.5 nm/a.u. (83).
In 2016, Zolkapli fabricated an optical pH sensor, as shown in Figure 17 (84). Based on optical fibre, it uses a plastic-clad silica fibre whose core was exposed and coated with a sol–gel matrix doped with bromophenol blue (BPB) as a chemical indicator. The detection principle is based on the interaction of the evanescent wave with the sensing coating, where changes in pH alter the optical absorbance of BPB in the visible region. The sensor showed a linear and reversible response over the pH range of 2–4, with a coefficient of determination of 0.996 and good coating stability, confirmed by FESEM and EDX analysis. In addition, statistical analysis using SPSS identified pH 2 as the most significant reference value (84).
In 2016, Mahdi developed an optical pH sensor based on evanescent-wave penetration. It was produced by removing the cladding from a multimode optical fibre, allowing the core to come into direct contact with the aqueous solution. The system operates through intensity modulation, whereby changes in pH alter optical absorption and transmission as a result of the interaction between the evanescent field and the analyte. Methyl red was used as an indicator to extend the detection range, achieving an almost linear response over the pH range 4–12 (85).
In 2017, Yinquan investigated a solid-state glucose sensor (GSM) that used a terminal-reflection optical fibre. The fabrication of the GSM is described, and the effects of variables such as thickness, GOD content, pH and temperature on the reflected spectrum are highlighted. The optimum parameters were identified as a thickness of 12 layers, a GOD content of 4 mg/mL, a pH of 7.0 and a temperature of 40 °C. The resonance wavelength decreased linearly with glucose concentration, with a sensitivity of 0.14 nm/(mg/dL). Experimentally, the resonance wavelength decreased from 679.50 nm to 656.9 nm in the visible range as the film’s refractive index decreased (86).
In 2017, Deng developed a fluorescence-based pH sensing system using optical fibre, specifically designed to measure very small-volume samples. The sensor uses bromocresol purple immobilised using sol–gel technology and deposited on the fibre tip by dip coating, enabling localised and efficient detection. The optical system incorporates an LED source, optical filters and a dichroic filter, allowing both the excitation light and the fluorescent signal to travel through a single fibre and improving the device’s collection efficiency and portability. In experiments, the sensor showed a linear response over the pH range of 5.3–8.7, with a correlation coefficient of 0.969 and response times on the order of tens of seconds (87).
In 2018, Gauthier-Manuel presented a calibration-free, fibre-optic pH sensor designed for clinical and physiological applications, using fluorescein grafted onto the end of an optical fibre. Unlike conventional approaches, the method is based on a comprehensive mathematical model of the fluorescence spectrum, enabling the simultaneous determination of pH and the effective pKa value and eliminating the need for prior calibration. The sensor exploits the multiple fluorescent prototropic forms of fluorescein, whose spectral contributions vary when the indicator is close to a solid surface, such as the tip of the fibre. The results demonstrate an accuracy of better than 0.1 pH units across the physiological range, positioning this strategy as a robust, minimally invasive solution for intracorporeal monitoring (88).
In 2020, Gutiérrez developed a micro-displacement sensor based on multimode optical fibre coupled to a Mylar® polymer film. The experimental configuration of the sensor was described (Figure 18) (89), and the influence of variables such as membrane displacement, temperature and system stability on the interference wavelength was highlighted. Optimal operating parameters were determined: a maximum sensitivity of 27.84 nm/μm, a resolution of 41.5 nm and low thermal dependence of 0.05 μm/°C. The wavelength of the interference peak centred at 552.1 nm showed a linear response to displacement, with consistent polynomial fits (R²₁ = 0.9899, R²₂ = 0.9626 and R²₃ = 0.9451). Experimentally, the sensor exhibited minimal fluctuations in power (0.4 dB) and wavelength (<2 nm), confirming its high stability and reliability for the precise detection of micro-displacements (89).
In 2020, Gutiérrez developed a low-pressure extrinsic Fabry-Perot fibre-optic sensor based on a 6 µm polyester thin film, analysed using the phase signal. The device operated over a range of 0–2 psi, showing a spectral shift towards the blue region with a sensitivity of approximately 10.5 nm/psi, a free spectral range variation of 15–25 nm, and a maximum visibility of 6 dB. Finite element analysis confirmed a linear response to stress, remaining below the material’s yield point. With a sensitivity of 3.5 rad/psi and the ability to overcome crosstalk effects and initial calibration, this sensor is presented as a versatile, highly sensitive alternative for detecting minimal pressure variations (90).
In 2020, Hameed Kareem presented the development of an optrode-type optical pH sensor based on transmittance measurements, designed for industrial applications and continuous monitoring, using the experimental setup shown in Figure 19 (91). The system uses a multimode glass (silica) optical fibre, whose cladding was removed at several sections along a 25 cm length to increase direct interaction between the guided light and the solution being analysed. Unlike sensors based on sensitive coatings, this approach relies on optical absorption and variations in the refractive index of the medium, avoiding problems associated with active layers, such as cracking or lack of homogeneity. The sensor showed a reproducible response over a wide pH range, from 2 to 10, with sensitivities between 0.015 and 0.2 pH⁻¹ (91).
In 2020, Islam reported an optical pH sensor based on an optical fibre coated with anatase (TiO₂) nanoparticles encapsulating the indicator dye phenol red, synthesised using a low-temperature sol–gel method. The mesoporous coating has a large surface area (~218 m²/g) and a highly porous morphology (Figure 20) (92), promoting efficient interaction between the fibre’s evanescent field and the external medium. The sensor exhibits a linear response over a wide pH range (1–12), with a sensitivity of approximately 1.83 counts/pH at 454 nm and an R 2 of 0.97, as well as fast response times (0.42–1.09 s) and good reversibility (92).
In 2021, Jauregui implemented a multimode optical fibre sensor coupled to a Mylar® membrane (Figure 21) (93) for the simultaneous detection of low pressure and liquid levels. The proposed experimental setup is shown in Figure 22 (93). The device exhibited a spectral shift towards the blue region, with sensitivities of 2.49 nm/kPa and 24.5 nm/m. Finite element analysis confirmed a linear response to stress, indicating that the material operates below its yield point. With a quadratic polynomial fit of R² = 0.9539, this sensor is emerging as a low-cost alternative for liquid-level and pressure-monitoring applications (93).
In 2021, Jáuregui developed a low-cost optical fibre sensor for monitoring respiration and humidity, based on silica optical fibres functionalised with (3-aminopropyl)triethoxysilane (APTES) and alginate. The device achieved a sensitivity of 3.1288 mV/RH, with a response time of 25 s and a recovery time of 8 s over a relative humidity range of 50–95%, making it a promising tool for studying human respiration (94). The sensor architecture is shown in Figure 23(a), which depicts a sandwich-type optical fibre structure formed by multimode fibre (MMF) sections interconnected by a no-core fibre (NCF), with the functionalised layer (F-layer) acting as the active sensing region. Figure 23(b), meanwhile, shows a simulation of the light-intensity propagation pattern along the NCF at a wavelength of 522 nm, illustrating how the optical field distribution varies between the MMF core and the NCF diameter. In the experimental system shown in Figure 24, a broadband LED (480-850 nm, λ = 522 nm, 132 µW) was used as the light source, coupling light through the functionalised structure, which was placed inside a test chamber exposed to controlled flows of humid air and hot air. Ambient humidity was monitored using a reference hygrometer, while a high-speed photodetector (400-1100 nm), connected to an oscilloscope, recorded the resulting fluctuations in optical power (94).
In 2021, Chen developed a fibre-optic pH sensor for the continuous monitoring of marine microenvironments, based on the evanescent-wave absorption principle. The sensing layer consists of a hybrid tetraethoxysilane (TEOS) and dimethyldiethoxysilane (DMDES) sol–gel matrix, optimised to improve retention of the indicator meta-cresol purple, thereby providing high stability and an extended service life. The sensor achieves an accuracy of approximately 0.02 pH units, meeting the climate-quality measurement criteria of the Global Ocean Acidification Observing Network (GOA-ON), and operates over a dynamic range of pHₜ 7.4–9.7 in seawater. It also offers response times of 2.5–6.5 minutes, a self-referencing design that requires no external electrodes, and straightforward spectrometric instrumentation. The sensor’s applicability was demonstrated through in situ, real-time measurements on the macroalga Ulva sp., showing its ability to monitor pH variations induced by metabolic activity at the microscale over several days (95).
In 2022, Wei proposed a visible-light spectral demodulation system for silicon carbide (SiC)-based fibre-optic Fabry–Pérot sensors (Figure 25) (96), intended for applications in extreme conditions. The experimental setup shown in Figure 26 (96) was used in this work. It comprised a broadband LED source in the visible range (470–850 nm), selected to minimise the inherent optical absorption of SiC, together with a miniature optical spectrum analyser to acquire the reflected spectrum from the interferometric cavity. The sensor consists of an air-filled Fabry–Pérot cavity formed between two SiC surfaces and optically coupled via a fibre collimator, allowing the fibre to be isolated from high-temperature environments. The absolute cavity length was interrogated using a quadratic cross-correlation algorithm, achieving a maximum relative error of 0.0437% in simulations for cavities between 15 and 25 µm. In experiments, a pressure sensor with an initial cavity length of approximately 16 µm showed a change in length from 15.911 to 15.840 µm over a pressure range of 100–500 kPa, with a sensitivity of 0.19357 nm/kPa (96).
In 2022, Kumar presented a portable, plug-and-play optical pH sensor based on optical fibre (Figure 27) (97), designed for in situ measurements in microfluidic systems. The device uses the fluorescent dye acrylamidofluorescein (AAF), immobilised at the tip of a multimode fibre, whose fluorescence intensity changes with pH, together with a reference dye (perylene red) that enables ratiometric detection and reduces errors caused by variations in temperature or source intensity. The sensor exhibits a sigmoidal response over the pH range 6.0–8.5, with maximum sensitivity near pH 7.5, and demonstrates stable operation in both static liquids and flowing microfluidic channels (97).

3.4. Plastic Optical Fibre

Plastic optical fibre (POF) is made from polymeric materials, such as polymethyl methacrylate (PMMA), rather than silica. It generally has a large core diameter, which makes it easier to couple light into the fibre and handle it, while also reducing alignment requirements during installation (67). Its high flexibility, low cost and mechanical strength also make it an attractive alternative for applications where silica fibres are less practical or more expensive (67).
Thanks to these characteristics, plastic optical fibres have been widely used in the development of sensors for detecting physical, chemical and biological parameters (68). Their high numerical aperture and the possibility of chemically modifying their surface promote interaction between the guided light and the external medium, enabling the design of sensors based on intensity, fluorescence, absorption and refractive index. In particular, POFs have attracted growing interest in biomedical applications, including the monitoring of glucose, oxygen, pH and other biomarkers of clinical interest, owing to their biocompatibility, ease of manufacture and ability to perform real-time measurements (68).
In 1980, Goldstein developed one of the first miniaturised optical pH sensors for in vivo physiological applications. It was based on detecting the colour change of an indicator dye (phenol red) contained in a cellulose hollow fibre permeable to H⁺ ions. The system uses visible light, with illumination in the green region (~558–560 nm), corresponding to the dye’s absorption maximum, and a reference signal in the red region (>610 nm) for ratiometric normalisation. The sensor is constructed from two separate plastic optical fibres (a polymer with a polystyrene core and PMMA cladding), each 0.125 mm in diameter: one for illumination and the other for detecting backscattered light. This configuration allows for a flexible, non-fragile design suitable for implantation. The device showed good agreement with conventional pH electrodes across the physiological range (pH 7.0–7.4) (98).
In 1993, Hao presented a fibre-optic pH sensor (Figure 28) (99), using phenol red as a colourimetric indicator immobilised inside a reaction chamber integrated into the optical path. The device uses a single-path configuration, which increases signal intensity and simplifies the processing and replacement of the dye. The sensor showed stable performance over the pH range 6.0–8.0, with good sensitivity and reproducibility, a response time of 2–5 minutes, and an operational lifetime of up to seven days with periodic calibration. However, the system’s main limitation was membrane degradation, associated with dye diffusion from the gel matrix, which affected its long-term stability (99).
In 2002, Lee developed an optical pH sensor based on a microbent optical fibre as an alternative to traditional evanescent-wave sensors using fibres with the cladding removed. In this work, a section of the fibre is permanently microbent and coated with a sol–gel film doped with pH indicator dyes (bromocresol purple, bromocresol green and cresol red), enabling a broad response over the pH range of 3 to 11. The operating principle is based on mode coupling induced by the microbends, whereby some of the power in the core modes is transferred to cladding modes, whose evanescent fields interact with the pH-sensitive coating. The system simultaneously uses bright-field detection (core modes) and dark-field detection (cladding modes), increasing measurement reliability (101). The experimental setup is shown in Figure 29 (100), where L denotes the diode laser (633 nm); C, the cell containing the pH solution; P, the pH electrode; F, the optical fibre; R, the refractive-index matching liquid; D1, detector 1 (Metrologic 45–545); and D2, detector 2 (Newport 1815-C).
In 2008, Binu conducted a series of experiments to detect the refractive index by varying the glucose concentration in distilled water across the visible range, at 660 nm. For this purpose, a sensor was designed comprising a plastic optical fibre probe, a reflective mirror, a temperature controller, a detector photodiode and a digital multimeter (Figure 30) (101). The results of this study show an impressive sensitivity of 0.0072 V/wt% for a concentration change from 0 to 25 g per 100 ml (101).
In 2009, Lomer developed a continuous liquid-level measurement sensor (Figure 31) (102), which uses two types of optical waveguides: optical fibres and hollow metal waveguides (HMWs). The optical fibre transmits light which, when coupled into the hollow waveguide, illuminates the liquid surface. The beams reflected from the surface are collected by another optical fibre. The detected optical intensity varies with distance. Coupling the transmitting optical fibre to the HMW increases the displacement measurement range considerably, as the light is concentrated within the metal tube without affecting the fibre’s numerical aperture, providing a sensitivity of 0.097 At. An LED with a wavelength of 660 nm was used as the light source, and a PIN diode as the detector (102).
In 2009, Sascha presented a distributed strain sensor based on polymer optical fibre (POF) and optical time-domain reflectometry (OTDR), evaluating both standard PMMA fibres and perfluorinated graded-index fibres (GI-POF, CYTOP type). The measurement principle is based on an increase in the level of Rayleigh backscatter in sections of fibre subjected to strain, compared with a reference signal. For standard PMMA fibre (Mitsubishi GH4001), sensitivity was characterised by a strain resolution of up to 0.1% under laboratory conditions, a spatial resolution of 0.1 m over short distances and 1 m over longer distances, and a measurement range of up to 100 m of fibre. This made it possible to detect medium and large strains of up to 40%, with negligible optical losses up to a strain of 15%. Cross-sensitivity to temperature was relatively low, with a slope of 15 × 10⁻⁶ K⁻¹ in the light transit time, equivalent to a backscatter change corresponding to just 0.2% strain for every 10 K change in temperature. By contrast, the perfluorinated GI-POF showed a non-linear backscatter response up to approximately 3% strain, but achieved a notably higher spatial resolution of 10 cm over fibre lengths of up to 500 m, thanks to its lower attenuation (30 dB/km) and graded-index structure. This fibre also exhibited considerably lower thermal sensitivity (a backscatter variation of less than 0.1 dB over a range of 100 K), making it more stable than standard POF in the face of environmental fluctuations. In field tests, the system proved capable of detecting crack openings up to 1 mm wide in masonry structures, as well as ground strains of up to 6%, validating its applicability to the structural monitoring of civil infrastructure and geotechnical structures (103).
In 2010, Souza led the development of passive devices for electromagnetic detection that transmit analogue signals via polymer optical fibres, using loop antennas, LEDs and PMMA plastic optical fibres. We demonstrated their operation in the high- and very-high-frequency bands (HF/VHF), detecting commercial AM and FM broadcasts transmitted in the far field. We used visible light at a wavelength of 650 nm and achieved a sensitivity of 5.6 mV/μW (104).
In 2012, Rovati reported the development of a pH sensor based on plastic optical fibre, in which a colourimetric indicator (phenol red) is immobilised in an organic–inorganic hybrid matrix prepared by the sol–gel method and deposited at the tip of the fibre. The sensing material consists of a PEO–silica hybrid, which improves adhesion to the plastic fibre, reduces indicator leaching and allows the response kinetics to be adjusted through swelling and contraction processes. The sensor operates on a colourimetric absorption principle in the visible region and has a pH measurement range of 5 to 8, high sensitivity, rapid response times (from seconds to minutes, depending on the direction of the pH change) and low cost (105).
In 2013, Bastien developed an innovative pH sensor using polymethyl methacrylate (PMMA) optical fibres in the visible-light range at 590 nm, designed specifically for bodily measurements. Detection is based on the absorption of evanescent waves in a thin film deposited on the fibre core. This sensitive film was produced using sol–gel technology, with a mixture of tetraethyl orthosilicate (TEOS) and methyltriethoxysilane (MTES) or phenyltriethoxysilane (PTES), resulting in a porous organic–inorganic hybrid layer upon drying. Test results demonstrated excellent sensitivity across a pH range of 3 to 9, with an optical signal variation of 3.5 dB (106). The experimental setup used is shown in Figure 32 (106) and consists of: (1) a 590 nm signal light source, (2) an 870 nm reference light source, (3) a photodiode and (4) a dichroic mirror. The sources are coupled to the fibre input using microlenses and the dichroic mirror, and are activated alternately. Light intensity is measured by the photodiode, and the optical signal is determined by the ratio of the intensities. Data are acquired using a USB-connected card.
In 2013, Roli introduced a revolutionary multi-analyte sensor design based on optical fibre and surface plasmon resonance (SPR), intended for the simultaneous detection of urea and glucose in biomedical applications. The sensor uses an innovative gel entrapment technique in a fluid, combining different metals and dielectric layers in two exposed areas of an optical fibre. It operates across a visible wavelength range of 500 to 800 nm, enabling the accurate and efficient detection of the aforementioned analytes (107). The experimental setup of the system is shown in Figure 33 (107).
In 2013, Ferreira designed and characterised an optical pH sensor based on plastic optical fibre (POF) and transmission-mode colourimetric detection. The device uses a silica sol–gel matrix (TEOS) to immobilise a universal pH indicator (Thymol Blue, Methyl Red, Bromothymol Blue and Phenolphthalein), positioned between two aligned plastic optical fibres that share the same optical axis. The sensor operates using visible white light from a superluminescent LED and a photodiode with a linear response across the visible range, recording changes in transmitted optical power associated with variations in pH (108).
In 2015, Qiu developed a tapered plastic optical fibre sensor coated with a graphene monolayer transferred onto a PMMA core, for glucose detection using the evanescent-field principle. The quality and uniformity of the graphene were confirmed by Raman spectroscopy, which revealed the characteristic D (~1360 cm⁻¹), G (~1570 cm⁻¹) and 2D (~2722 cm⁻¹) bands, with an intensity ratio I(2D)/I(G) ≈ 2.2, consistent with a high-quality monolayer structure with a low defect level. The sensor’s sensitivity was evaluated using a 628 nm LED source and glucose solutions with concentrations ranging from 1% to 40%. The results showed that the output light intensity decreases as the glucose concentration increases. This is attributed to the increase in the solution’s refractive index, which in turn increases the penetration depth of the evanescent field and, consequently, the loss of optical energy. Over the range studied, the output intensity fell from 295,000 to 27,500 a.u., showing an almost linear relationship at specific wavelengths close to 625–630 nm. Comparison with an identical fibre without a graphene coating showed that its output signal fluctuated more and had a notably poorer linear relationship between optical intensity and glucose concentration. This led to the conclusion that adding the graphene layer significantly improves the sensor’s sensitivity, stability and reliability. This improvement is attributed to graphene’s active π electrons, which enable it to adsorb glucose molecules firmly and uniformly onto the fibre’s sensing region (109).
In 2015, Islam developed an optical pH sensor based on optical fibre with a multilayer sol–gel coating, in which a mesoporous SiO₂–TiO₂ hybrid matrix encapsulates a mixture of pH indicators. The sensing material is deposited in multiple coatings onto an uncoated plastic-clad silica (PCS) optical fibre, improving sensitivity and preventing the formation of cracks observed in single-layer coatings. The sensor operates over a wide pH range (3–11), offers high transparency in the visible region and good stability, prevents dye leaching, and exhibits a pH-dependent optical response associated with the interaction of the analyte with the interconnected pores in the coating (111). Figure 34 (110) shows the microscopic images obtained at 5× magnification: (a) bare fibre, (b) fibre coated with a single layer, (c) fibre coated with two layers, and (d) fibre coated with three layers.
In 2016, Cristina implemented a system using a single-core plastic optical fibre with specific dimensions: 15 inches in length, an internal diameter of 1.96 mm and an external diameter of 3 mm. The fibre was supplied by Edmund Optics, based in Barrington, New Jersey, USA. The system operated in the visible-light range, from 366 to 540 nm, with glucose samples at concentrations of 4 to 20 μM. To improve the system’s sensitivity, a structure of Ni-NTA-doped agarose beads was used (Figure 35) (111), yielding a measured sensitivity of 2.888 ± 0.08085 (111). Figure 35(a) shows a schematic of the fibre-optic glucose biosensor, which incorporates a nylon tube containing GFP/Ni-NTA beads, secured to the end of the optical fibre with a nylon mesh. Figure 35(b), meanwhile, shows a photograph of the biosensor in operation, with light emitted from its tip and a penny beside it for scale.
In 2016, Obrovski reported the development of a fibre-optic pH sensor capable of measuring multiple parameters using a simple, low-cost colorimetric probe while maintaining a high level of accuracy. The proposal is based on the HSV colour model, which provides an intuitive, user-oriented approach to the quantitative analysis of colour changes associated with different chemical species. The sensor’s performance was validated by comparing the concentrations of orthophosphate, nitrite, sulphate, hexavalent chromium (Cr(VI)) and total chlorine obtained using conventional laboratory methods with those measured by the proposed system (Figure 36) (112). The results show relative differences ranging from 2.31% to 6.20%, demonstrating good agreement and confirming the device’s suitability for analytical applications (112).
In 2017, Yuniato designed a revolutionary sensor for the precise detection of blood glucose levels. The device uses a plastic optical fibre and relies on the emission of green LED light to take measurements. The proposed experimental setup is shown in Figure 37 (113). Evaluation is carried out using a UV–VIS spectrometer, which produces results at a wavelength of 581 nm. The linear regression coefficients obtained were 0.97 and 0.94, respectively, validating the accuracy of the system. The sensor has been meticulously calibrated and tested using samples covering a wide range of glucose concentrations, from 81.2 to 235.1 mg/dl (113).
In 2017, Zhao developed a sensor that uses acetic acid at an ultrasonic power of 130 W and a temperature of 25 °C. The sensor exhibits a high sensitivity of 9.10 RIU g/L−1 for glucose solutions with concentrations ranging from 10% to 80%. The results are obtained over a spectrum spanning 500 to 750 nm (114).
In 2018, Mikel presented a study in which two liquid-core microstructured polymer optical fibres (LC mPOFs) were used in a Raman spectroscopy-based sensing platform to detect glucose in aqueous solutions of clinical interest. The experimental setup is shown in Figure 38 (115). During the study, Raman spectra were recorded and compared using excitation in the visible range between 450 and 500 nm. The tests were carried out by immersing the sensor for 10 minutes in solutions with glucose concentrations ranging from 0 mmol/L to 25 mmol/L (115).
In 2019, Moradi presented a fluorescence-based pH sensor integrated into a microfluidic platform (Figure 39) (116), featuring fibre-optic detection and designed to cover a wide pH range. The system uses the fluorescent dye trisodium 8-hydroxypyrene-1,3,6-trisulphonate (HPTS) as its sole indicator. This is dynamically mixed with the sample inside a static micromixer, avoiding the problems associated with immobilising the dye. The fluorescence generated by exciting the HPTS with a blue laser (445 nm) is collected and guided to a photodiode via an optical fibre, establishing a direct correlation between fluorescence intensity and the pH of the solution. The sensor provides a reproducible response over the pH range 2.5–9.0, with linear relationships across different subranges and a response time of around 10 s (116).
In 2021, Gomes developed an absorber based on a metal/dielectric bilayer structure (Figure 40) (117). This planar absorber exploits Fabry-Pérot resonance and the inherent losses of metals to achieve maximum light absorption in the visible region of the electromagnetic spectrum, specifically at 694.8 nm, as well as in the near-infrared. The sensitivity achieved is ±2 nm (117).
In 2021, José developed a low-cost, high-sensitivity optoelectronic device based on a 20 cm-long U-shaped plastic optical fibre (Figure 41) (118) to detect adulteration in liquids. The device, comprising a 3 W white LED and an RGB photodiode array, achieved a resolution of 0.3% by weight in tequila–water mixtures, with sensitivities of 0.1, 0.6 and 0.4 8-bit units per % by weight for the red, green and blue channels, respectively. This system is emerging as an economical and efficient alternative for the automated detection of adulteration in alcoholic beverages (118).
In 2022, Arnaldo developed a fibre-optic sensor system capable of performing multiparametric measurements, specifically designed to assess the temperature and turbidity of liquid samples. The experimental setup is shown in Figure 42 (119). The sensors combine fibre Bragg gratings (FBGs), intensity-variation sensors and surface plasmon resonance (SPR) sensors. The SPR sensor is used as a complementary method to extend the dynamic range for turbidity assessment; over a range of 680 nm, it achieves 98.6% linearity and a sensitivity of 313.5 nm/RIU (119). The components of the experimental system are arranged as follows: (a) shows the configuration for intensity detection, illustrating the illuminated fibre connected to a laser, a container with a sphere, and the unilluminated fibre coupled to a spectrometer; (b) shows the setup with the fibre Bragg grating (FBG) integrated into a support block and connected to an optical interrogator; and (c) presents the surface plasmon resonance (SPR)-based configuration, which uses a halogen lamp as the light source, a central test cell containing a gold-coated D-shaped fibre, and a spectrometer to record the optical response (119).
In 2023, Lomer developed an innovative fibre-optic displacement sensor featuring a diffraction grating positioned at the angled end of a POF fibre. The device measures two diffraction orders: one as a reference and the other as a function of displacement. The sensor is constructed by inserting a multimode diffraction grating into the end faces of the optical fibre, using only the zeroth and first orders. A wavelength of 660 nm, within the visible range, was used to demonstrate the operation of the displacement sensor (120).
In 2023, Yunus presented a U-shaped optical fibre pH sensor (Figure 43) (121), designed to characterise aqueous solutions by measuring optical power losses. The sensor’s performance was evaluated by varying the length of the uncoated fibre, the bend diameter and the number of imperfections introduced into the fibre. The results show that greater optical losses lead to higher sensitivity and better sensor resolution. The best performance was achieved with three structural imperfections, a sensitivity of 3.2 µW/pH and a resolution of 0.3 × 10⁻³ pH (121).
In 2024, Elsherif presented a fibre-optic pH sensor in which detection is based on the interaction between guided light and the surrounding medium, exploiting the optical variations induced by changes in the solution’s pH. The sensor’s performance was evaluated using parameters such as sensitivity, measurement range and stability, and a reproducible, suitable response was demonstrated within the pH range studied. Figure 44 (122) shows the response of the neutral red dye at different pH values. (a) Chemical structure of neutral red in a basic medium (left) and an acidic medium (right). (b) Image of neutral red dye in deionised water at pH 5, 6, 7 and 8. (c) Absorption spectra of neutral red in aqueous solutions at different pH values. (d) Positions of the absorption maxima for solutions at pH 5, 6, 7 and 8. (e) Transmission spectra of neutral red in aqueous solutions at pH 5, 6, 7 and 8.
In 2025, Liang developed a polymer optical fibre microprobe doped with CdSe/ZnS quantum dots, fabricated by free-radical photopolymerisation at the end of an optical fibre. The sensor exhibits high flexibility, good biocompatibility, structural stability and ease of functionalisation, as well as precise control over probe size. Experimentally, a sensitivity of 0.18097 pH⁻¹ was achieved across the pH range of 4.5–9.0, with a highly linear response (R² = 0.99448). Liang developed a polymer optical fibre microprobe doped with CdSe/ZnS quantum dots, fabricated by free-radical photopolymerisation at the end of an optical fibre. The sensor exhibits high flexibility, good biocompatibility, structural stability and ease of functionalisation, as well as precise control over probe size. Experimentally, a sensitivity of 0.18097 pH⁻¹ was achieved across the pH range of 4.5–9.0, with a highly linear response (R² = 0.99448) (123). The experimental setup used is shown in Figure 45 (123): (a) Fabrication process for the polymer optical fibre microprobe (POF MP) doped with CdSe/ZnS quantum dots. (b) SEM image of the POF microprobe doped with CdSe/ZnS. (c) Experimental setup for pH detection.

4. Instrumentation and characterisation tools for sensor development

4.1. Optical and spectral characterisation instrumentation

In 2014, Alonso developed an automated system for the precise measurement of attenuation (Figure 46) (124) and dispersion (Figure 47) (124) in plastic optical fibres (POF). The system uses a mode scrambler to achieve rapid mode equilibration, thereby minimising insertion losses. It is also equipped with a monochromator and two lamps, which together cover both the visible and near-infrared spectra, spanning wavelengths from 350 nm to 1700 nm (124).
In 2015, Itxaso conducted a study on light amplification in plastic fibres doped with rhodamine 6G, with a core concentration of approximately 12 ppm by weight. The experimental setup is shown in Figure 48 (125). It included an Nd:YAG laser as the excitation source, a second-harmonic generator (SH), a beam splitter (S) and an iris (I) to control the beam. Adjustable filters (VF), a diverging lens (L1), a converging lens (L2) and a cylindrical lens (L3, f′ = +15 cm) were also used for optical conditioning. The system was complemented by a movable slide (SL), micropositioners (POSxy), a filter holder (FH) and a fibre-optic spectrometer (FOS) for spectral analysis. During the study, a blue shift and spectral narrowing were observed in the emission spectra as the excitation length increased. The fibre’s optical gains were also calculated for various emission wavelengths and three excitation intensities, with higher gains at higher intensities. The maximum values were found at λ = 565 nm in all three cases analysed (125).
In 2017, Alvarado compared and analysed the optical absorption spectra of blood from male Fisher rats using photoacoustic spectroscopy (PAS), with the experimental setup shown in Figure 49 (126). Commercial turmeric was used in the study. After anaesthesia with ethyl ether, blood was drawn and collected in tubes containing ethylenediaminetetraacetic acid (EDTA) as an anticoagulant. A 60 ml blood sample was analysed by PAS over a wavelength range of 350-650 nm. The characteristic α, β and γ absorption peaks of blood were expected to appear at around 575 nm, 540 nm and 412 nm, respectively, the last corresponding to the Soret band (126).
In 2018, Rubio created an alternative spectrometer using a Raspberry Pi 3 and open-source software (Figure 50) (127) to measure the wavelengths of different light sources and design single-mode fibre sensors in the visible range. Premium optical fibre and an LS-1 tungsten–halogen light source were used. The software was based on Ocean Optics® SpectraSuite, and LEDs ranging from 410 to 630 nm were tested. The results were compared with those from an Ocean Optics® USB4000 spectrophotometer and its OceanView software (127).

4.2. Synthesis and modification of materials

In 1999, Bartoli conducted a study in which thin PMMA films were treated with CF4+H2 plasma to alter their refractive index (R.I.) through fluorination, using a wavelength of 632 nm in the visible range. Characterisation revealed the formation of a polymeric hydrofluorocarbon layer, which reduced the R.I. from 1.49 to 1.43, with the fluorine concentration increasing gradually with depth. This technique proved effective in improving the surfaces of polymer optical waveguides and fibres, leading to reduced losses and increased data transmission speeds (128).
In 2023, Awras faced an environmental challenge due to the presence of methyl orange in industrial wastewater, which affects aquatic ecosystems and human health. A continuous wave of 60 watts and a high-power CO₂ laser were used to address this problem. A shift in the absorbance spectra of pure ZnO and ZnO nanoparticles (NPs) doped with 1% cerium (Ce), around 400 nm, towards the visible spectrum was observed using a 10.6 μm laser and the laser-assisted chemical bath synthesis (LACBS) technique. The nanostructures were characterised using UV–vis spectroscopy, field-emission scanning electron microscopy (FESEM) and X-ray diffraction (XRD) (130). Figure 51 (129) shows: (a) the experimental setup using the CO₂ laser; (b, c) digital photographs showing the synthesis of pure ZnO nanoparticles after irradiation with the CO₂ laser in the ceramic crucible, and the production of ZnO nanoparticles doped with 1% Ce, respectively. Further results are presented in Figure 52 (129).

4.3. Optical signal processing components and systems

In 2017, Marcello developed an innovative variable optical attenuator (VOA) designed specifically for plastic optical fibres (POFs), known as the POF-VOA. This device uses photochromic polymers (PFCs) to achieve precise control of optical attenuation. The experimental setup used is shown in Figure 53 (130). Controlled by photo-induced opacity from a low-power LED, the POF-VOA can produce up to approximately 10 dB of attenuation in a 525 nm optical carrier signal transmitted through the POF. It is also notable for its control optical power density of less than 0.5 mW/mm², ensuring safe and efficient operation (130).
In 2017, Rafaella fabricated WDM demultiplexers (DEMUXs), the layout of which is shown in Figure 54 (131), for use with PMMA optical fibres and diode lasers in the visible spectrum. The DEMUXs achieved an insertion loss of 1.50 dB or less, representing notable performance for this type of device. The results showed an insertion loss of less than 10 dB in each branch and a rejection of 44.2 dB at 633 nm, providing a signal-to-noise ratio of 34.4 dB.
In addition, the 520 nm signal was completely blocked using a red filter because of the limited sensitivity of the optical power meter. The multiplexers (MUXs) were constructed by combining splitters with plastic gel optical filters. The bidirectional communication system using plastic optical fibre (POF) and two wavelength-division multiplexing (WDM) channels is shown in Figure 55 (131).
In 2019, Antonio developed a visible light communications (VLC) receiver using an innovative plastic optical fibre antenna. This device (Figure 58) (40) is equipped with an integrated optical power meter (MPO) photodiode, specifically Thorlabs’ PM20A model, with an impressive sensitivity of 50 dBm. It also incorporates a high-efficiency LED from Diemount GmbH, which emits blue light (~460 nm). With a nominal optical output power of 4 mW at a current of 20 mA, this receiver ensures optimum performance in the transmission and reception of optical signals (40).
Figure 56. Schematic of the experimental setup for comparing different types of plastic optical antennas, highlighting the VLC receiver with a dotted rectangle (40).
Figure 56. Schematic of the experimental setup for comparing different types of plastic optical antennas, highlighting the VLC receiver with a dotted rectangle (40).
Preprints 240007 g056

4.4. Detection systems and specialised applications

In 2007, Lomer developed and validated an alarm system for flammable liquids based on the thermal sensitivity of poly(N-isopropylacrylamide) (PNIPAAm) hydrogel (132). Figure 57 shows (a) the structure of the telechelic polymer, (b) the amide group and (c, d and e) the structural components of the N-isopropylacrylamide (NIPAAm) monomer, as well as the formation of the hydrogel network. The lower critical solution temperature (LCST) of PNIPAAm was established at 32 °C; by incorporating different concentrations of 2-methyl-2-oxazoline (MeOXA), its thermal response can be adjusted up to 75 °C. Figure 58 shows the experimental set-up, in which the light source emits the optical signal, the optical fibre guides it towards the hydrogel, and the detector records the intensity variations generated by the material’s thermal response when in contact with the flammable liquid (132).
Figure 57. Chemical structure of Poly(NIPAAm) hydrogel and 2-methyl-2-oxazolines (132).
Figure 57. Chemical structure of Poly(NIPAAm) hydrogel and 2-methyl-2-oxazolines (132).
Preprints 240007 g057
Figure 58. Diagram of the sensor alarm (132).
Figure 58. Diagram of the sensor alarm (132).
Preprints 240007 g058
In 2010, Souza led the development of passive devices for electromagnetic detection that transmit analogue signals via polymer optical fibres, using loop antennas, LEDs and PMMA plastic optical fibres. We demonstrated their operation at high and very high frequencies (HF/VHF), detecting commercial AM and FM bands transmitted in the far field. We used visible light at a wavelength of 650 nm and achieved a sensitivity of 5.6 mV/μW (133).
In 2023, Jing developed an innovative method called Clear Air Turbulence Detection (CAT) (Figure 59) (133), which uses visible light at 532 nm to detect atmospheric turbulence. A laser radar (LiDAR) system was proposed to address a crucial challenge in aviation safety. The LiDAR was evaluated at different altitudes and turbulence levels, and demonstrated the ability to detect CAT at distances of up to 7 km in light to moderate turbulence conditions and up to 10 km when moderate turbulence was present ahead of the aircraft. This is significant because traditional ultraviolet LiDAR systems fail when the aerosol-to-molecular backscatter ratio reaches 10⁻¹ (133).

5. Discussions

The results of this review show that optical fibre sensors operating in the visible region have evolved from configurations based primarily on changes in intensity, absorption and fluorescence towards systems incorporating interferometry, surface plasmon resonance (SPR), functional materials and advanced signal-processing strategies (134-137). This evolution demonstrates that sensor performance depends not solely on the type of fibre, but on the interaction between the optical architecture, the transduction mechanism, the sensing material and the interrogation system (134, 135). The applications identified include the measurement of pH, glucose, temperature, curvature, humidity and other parameters, confirming the versatility of these platforms in chemical, physical and biomedical applications (134–136).
Regarding the platforms used, the review shows a greater prevalence of multimode fibres and plastic optical fibres in pH applications, whereas single-mode and photonic fibres are used in applications requiring greater control over optical propagation. This difference may be related to the characteristics of each type of fibre and the detection mechanism employed (134, 137). Multimode fibres, for example, facilitate light coupling and its interaction with the external medium, favouring strategies based on absorption, fluorescence and the evanescent field (134, 138, 139). By contrast, single-mode fibres allow greater modal control and are particularly suitable for interferometric configurations and applications in which small optical variations must be detected precisely (134, 140).
Table 1 presents the main advantages and disadvantages identified for each type of optical fibre sensor operating in the visible region. Sensors based on functionalisation with nanomaterials, such as those modified with carbon nanotubes, can achieve significantly higher sensitivities than conventional configurations, although this entails greater complexity and increased manufacturing costs. By contrast, sensors based on absorption and pH detection are notable for their relative ease of manufacture and low cost, features that are particularly relevant to their use in complex matrices. Sensors designed for structural and environmental applications, such as measuring curvature, temperature, humidity and turbulence, offer an intermediate balance between robustness and accuracy, with performance depending largely on the operating wavelength and calibration conditions. Overall, this comparative overview shows that selecting a sensor configuration requires consideration not only of the parameter of interest, but also of the balance between sensitivity, cost, manufacturing complexity and operational stability.
One of the main findings is the evolution of the sensing materials used for pH detection (75-79). The studies reviewed range from conventional colourimetric indicators and sol-gel coatings to polymers (77, 79), hydrogels (81) and quantum dots. The most recent developments based on ZnCdSe/ZnS (73) and CdSe/ZnS (83, 123) show how incorporating nanomaterials makes it possible to harness photoluminescence phenomena and modify the interaction between light and the analyte. For example, sensitivities of 0.139 pH⁻¹ and 0.18097 pH⁻¹ were reported for quantum-dot-based sensors (73, 123), highlighting a trend towards developing materials with greater functionalisation capacity and miniaturisation potential.
The performance of the sensors reviewed should be compared with caution. Table 2 presents results expressed in different units, including nm/pH, µW/pH and pH⁻¹, as well as parameters such as resolution and measurement range. For this reason, a direct comparison based solely on sensitivity is not possible (135, 136, 141). For example, the U-shaped fibre sensor reported a sensitivity of 3.2 µW/pH and a resolution of 0.3 × 10⁻³ pH; however, these parameters describe different aspects of analytical performance and are
not directly equivalent (121). Accordingly, future research should report parameters such as sensitivity, resolution, limit of detection, repeatability, stability and response time more consistently.
Another relevant finding is the concentration of the devices studied in the visible region, mainly between 400 and 700 nm. This range is compatible with various colorimetric indicators and photoluminescent materials identified in the review (75,83,87,116), and also allows the use of relatively accessible optical sources and detection systems. However, the choice of a particular wavelength should be determined by the optical properties of the sensing material and the spectral response of the analyte, rather than by the operating spectral region alone.
Despite the advances identified, limitations remain regarding the stability of sensitive materials, the reproducibility of coatings and the difficulty of directly comparing results obtained under different experimental conditions (135,137,138). In addition, many of the sensors reviewed have been evaluated primarily in controlled solutions, so validation in real matrices is still needed to demonstrate their practical applicability. In this respect, future development should not focus solely on increasing sensitivity, but also on improving stability, selectivity, reproducibility and the ability to operate under real-world conditions.
Overall, the results reviewed show that optical fibre sensors operating in the visible region offer a promising platform for pH sensing applications in fields such as biomedicine, environmental monitoring and industry (135,138). Advances in sensing materials, particularly through the incorporation of polymers, nanomaterials and photoluminescent structures, have broadened the design and functionalisation possibilities for these devices. Table 2 summarises the main characteristics of the sensors analysed, including the type of fibre, sensing configuration, sensing material, operating wavelength and performance parameters, providing a basis for identifying trends and development opportunities in this field.
Table 2 illustrates the diversity and significant progress of optical fibre sensors in the visible-light range, with a clear predominance of multimode (MMF) and plastic (POF) fibres used for pH measurement, compared with the smaller number of single-mode (SMF) and photonic fibres, which are mainly geared towards glucose detection. The transduction mechanisms employed are equally varied, ranging from classic colorimetric indicators such as phenol red, methyl red and bromocresol purple to more sophisticated approaches based on quantum dots (CdSe/ZnS, ZnCdSe/ZnS), doped sol-gel coatings and intrinsic RGB/HSV colourimetry. Sensitivity values varied considerably, from 0.01 pH to more than 150 nm/pH, demonstrating that performance depends strongly on both the substrate and the wavelength used, which is predominantly in the 400–700 nm range. The table also shows complementary applications, including the detection of pressure, curvature, temperature and humidity, confirming the versatility of these platforms beyond chemical sensing. The presence of fields marked N/A for some structural or sensitivity parameters points to limitations that future research could address. Overall, this overview highlights the potential of these technologies to continue evolving, particularly through integration with systems and devices to achieve greater sensitivity and versatility, as shown in Table 3, and to consolidate their relevance in scientific and industrial fields.
Table 3 presents devices which, although not directly related to fibre-optic sensors, play an important role as technological infrastructure for their development and characterisation. The studies included describe tools for spectral measurement, characterisation of optical sources, analysis of attenuation and dispersion, as well as automated systems for signal acquisition and processing. Their inclusion demonstrates that sensor development depends not solely on the sensing element, but also on an instrumentation chain capable of generating, controlling, measuring and interpreting the optical response. These devices therefore represent a complementary component of sensing technology and provide a basis for improving the reproducibility, characterisation and validation of sensors developed subsequently.
Finally, the review highlights a trend towards the integration of advanced materials, miniaturised optical systems and computational processing tools. The use of quantum dots, functionalised structures and machine-learning algorithms shows that visible-light optical fibre sensors are evolving into more integrated and intelligent systems. Taken together, the findings suggest that future research should seek a balance between sensitivity, stability, ease of manufacture and cost, while also establishing more consistent characterisation protocols. This will help move from devices demonstrated under laboratory conditions towards sensors with greater potential for use in biomedical, environmental and industrial settings.
Table 3 presents a summary of the non-sensing devices identified in the literature. Although they do not perform a sensing function, they are relevant as technological and methodological precursors to the development of optical fibre sensors. These devices reflect a gradual evolution: first in the characterisation and synthesis of optical materials, then in fibre-based signal processing, and finally in adapting this knowledge to more specialised detection applications. Advances in optical characterisation instrumentation, materials manufacturing processes and signal-processing components gradually enabled the development of the optical fibre sensors described in the preceding sections of this wo

6. Conclusions

This review highlights the remarkable advances in optical fibre sensors operating in the visible spectrum, emphasising their transformative impact on biomedical, industrial and environmental applications. The various interferometric configurations—Michelson, Mach-Zehnder, Fabry-Pérot and Sagnac—demonstrate exceptional sensitivity in detecting physical parameters such as displacement, temperature, pressure and rotation. Innovations in photonic, single-mode, multimode and plastic optical fibres have enabled precise measurements, particularly in glucose detection and structural health monitoring, with sensitivities of up to 23,267.3 nm/RIU and cost-effective designs that improve accessibility. The integration of advanced techniques, such as surface plasmon resonance and machine learning, and novel materials such as PNIPAAm and sol-gel films, has further expanded these sensors’ capabilities, enabling real-time, high-precision monitoring in complex environments.
Despite these achievements, challenges remain, including thermal stability, birefringence compensation and the need for standardised calibration protocols. Future developments should focus on improving spectral resolution, miniaturising components and integrating digital platforms to optimise sensor performance and reproducibility. Visible-spectrum optical fibre sensors are poised to play a crucial role in advancing precision measurement technologies, offering versatile and scalable solutions to emerging scientific and industrial demands.

Author Contributions

Methodology, A.J.-R., J.G.-G., L.L.H.-G. and J.L.C.-P.; Validation, M.V.-T. and C.P.-M.; Formal analysis, L.L.H.-G., E.I.G.-H, M.A.M.-C. and A.J.-R.; Investigation, A.J.R., L.G.-R and J.F.A.-A.; Writing—original draft, A.J.-R.,J.G.-G., J.-A. and J.L.C.-P.; Writing—review & editing, A.J.-R., J.G.-G., M.V.-T. and J.L.C.-P.; Visualization, A.J.-R.,C.P.-M. and E.I.G.-H.-; Supervision, A.J.-R. and E.I.G.-H.; Project administration, J.L.C.-P.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Data Availability Statement

Data are contained within the article.

Acknowledgments

The Secretariat of Science, Humanities, Technology and Innovation (SECIHTI) is acknowledged for providing the resources needed to carry out this project (grant number 2109189).

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Fernández-Ordóñez, J.M.; Jiménez, L.E.M.; Torres, P.; Barba-Guamán, L.; Rodríguez-Morales, G. y/o Recursos Digitales Accesibles: Una Revisión.
  2. Ormaza, A.M.; Saavedra, B.F.; Moreno, R.A.; Polo, R. Estudio de la Aceptación y la Respuesta del Usuario ante la Biometría y sus Diferentes Modalidades. [PubMed]
  3. Zanuy, M.F. Experimentos prácticos sobre la vulnerabilidad de sistemas biométricos. [PubMed]
  4. Escobar JAM. M. Sc FRANCISCO ALEJANDRO MEDINA AGUIRRE. (46).
  5. Rueda, J.S.; Talavera Portocarrero, J.M. Similitudes y diferencias entre Redes de Sensores Inalámbricas e Internet de las Cosas: Hacia una postura clarificadora. Rev. Colomb. Comput. 2017, 18(2), 58–74. [Google Scholar] [CrossRef]
  6. Cano Perez, J.L.; Gutiérrez-Gutiérrez, J.; Perezcampos Mayoral, C.; Pérez-Campos, E.L.; Pina Canseco, M.D.S.; Tepech Carrillo, L.; et al. Fiber Optic Sensors: A Review for Glucose Measurement. Biosensors 2021, 11(3), 61. [Google Scholar] [CrossRef] [PubMed]
  7. Leal Hernández, M.; Álvarez De Sotomayor, M.S.; Hernández Martín, A.; Román Garcia, C.; Miralles Jimenez, F. No estamos solos. Motivos de consulta al gabinete médico-jurídico del sindicato médico de Murcia. Aten. Primaria 2020, 52(10), 801–2. [Google Scholar] [CrossRef] [PubMed]
  8. Moreno, I.; Serracín, J. Matriz de sensores: fundamento de la nariz electrónica. [CrossRef]
  9. Bastidas, S.E.C.; Cabrera, A.A.; Meza, H.E.C. SISTEMA EN TIEMPO REAL PARA EL MONITOREO DE VARIABLES MÉDICAS EN PACIENTES HOSPITALIZADAS CON REDES WSN. Publicaciones E Investig. 2019. [Google Scholar] [CrossRef]
  10. Viloria Núñez, C.A.; Sanmartín Mendoza, P.; Avila Hernández, K.; Jabba Molinares, D. Internet de las cosas y la salud centrada en el hogar. Salud Uninorte 2022, 32(02), 337–51. [Google Scholar] [CrossRef]
  11. Toloza, J.; Leiva, L.; Riba, A.; Carmona, F.; Acosta, N. Desarrollo de un prototipo de sistema portátil para la detección en tiempo-real de la necesidad de riego en cultivos de producción intensiva. 2010. [Google Scholar] [PubMed]
  12. Perdigones, A.; Nolasco, J.; Muñoz, M.A.; Pascual, Y.V. Sensores para el control climático en invernadero. 2004. [Google Scholar] [CrossRef]
  13. Sánchez, J.C.R.; Calderón, A.E.; Medina, J.A.P.; Carmona, J.J.D. IMPLEMENTACIÓN EN FPGA DE SENSOR DE TEMPERATURA Y HUMEDAD RELATIVA PARA UNA FUTURA PLATAFORMA DE MONITOREO AMBIENTAL. 120. [PubMed]
  14. García Navarrete, G.; Rico Soto, K.G. SENSORES DE BAJO COSTO PARA EL MONITOREO DE CALIDAD DEL AIRE. EPISTEMUS 2020, 13(27), 30–7. [Google Scholar] [CrossRef]
  15. Atempa Camacho, J.A.; Díaz-Ramírez, A.; Ayala Figueroa, R.I.; Quintero Rosas, V. Red de sensores inalámbrica para la detección de incendios forestales. Res. Comput Sci. 2015, 107(1), 73–85. [Google Scholar] [CrossRef]
  16. Enciso Suárez, J.R.; Portilla Rodriguez, J.E.; Mendoza De Los Santos, A.C. Análisis integral de los sistemas de detección de intrusos y sus algoritmos asociados en la seguridad de la información. Ing. Investig. 2023, 5. [Google Scholar] [CrossRef]
  17. Bravo, J.A.F. Nuevos esquemas de sensores puntuales de fibra óptica para la detección simultánea de múltiples parámetros. [PubMed]
  18. Salgado, P.; Hernanz-Sanjuán, M.L. DESARROLLO DE UN MÉTODO DE CALIBRACIÓN DE INTERROGADORES DE REDES DE BRAGG EN FIBRA ÓPTICA. 2010. [Google Scholar] [PubMed]
  19. Lomer, M. Fenómeno speckle en fibra ópticas y sus aplicaciones en sensores. TECNIA 2012, 22(2), 5–16. [Google Scholar] [CrossRef]
  20. Salgado, P. Method of calibration for fiber Bragg grating interrogators. Opt. Pura Apl. 2012, 45(3), 361–8. [Google Scholar] [CrossRef]
  21. Rodríguez-Barrios, F.; Martín-López, S.; Carrasco-Sanz, A.; Corredera, P.; Fuentes-Hernández, E.; Hernanz, M.L.; et al. Sensor distribuido Brillouin de deformación y temperatura en fibra óptica asistido con Raman para aplicaciones de ingeniería civil. [PubMed]
  22. Alustiza, D.H.; López, A.; Mineo, M. Introducción a los sensores de fibra óptica para el monitoreo de salud de estructuras civiles. 2022, 4, 4. [Google Scholar]
  23. Alustiza, D.H.; Russo, N.A.; Villagrán Zaccardi, Y.A. Aplicación de Redes de Período Largo en Fibras Ópticas para la Sensorización de Materiales Cementíceos. AJEA 2020, (5). [Google Scholar] [CrossRef]
  24. Hense CR. Tiempo de vida de fibras ópticas de vidrio bajo fatiga. Modelos y predicciones. 1992.
  25. Villa DEO, 25; Escobar, G.J.G. CONTROL DE UN SISTEMA DE ILUMINACIÓN BASADO EN FIBRA ÓPTICA Y ENERGÍAS RENOVABLES. 2009. [Google Scholar]
  26. Rodriguez-Ramirez, D.A.; Martinez-Angulo, J.R.; Filoteo-Razo, J.D.; Elizondo-Leal, J.C.; Diaz-Manriquez, A.; Jauregui-Vazquez, D.; et al. Review of Optical Fiber Sensors: Principles, Classifications and Applications in Emerging Technologies. Photonics 2025, 13(1), 40. [Google Scholar] [CrossRef]
  27. Henríquez, F.N. P royecto eBridge 2.0 utiliza sensores de fibra óptica FBG para monitoreo de la salud estructural de puentes. [PubMed]
  28. Galindo, J.; Alcón, M.; Carrasco, A.; Martín, S.; Corredera, P. Desarrollo de patrones de frecuencia en el IR basados en láseres de diodo Development of IR frequency standards based on laser diodes. 2012. [Google Scholar] [PubMed]
  29. Duarte, J.E.; Morales, F.H.F.; Sereno, M.; Almerich, J.M.; Andrés, M.V. Metrología por fibra óptica para la detección de pequeños desplazamientos. 2010. [Google Scholar] [PubMed]
  30. Hongn, M. MEDIDAS DE REFLECTANCIA ESPECTRAL PARA ESPEJOS UTILIZADOS EN LA CAPTACIÓN DE ENERGÍA SOLAR. [PubMed]
  31. Uso de los sensores de fibra óptica en la detección de gases en el ambiente. Rev. Ing. 2000, (11), 41–5. [CrossRef]
  32. Pedro, D.; Luz, M. ESPECTROSCOPÍA DE INFRARROJO CERCANO (NIRS) EN EL ANÁLISIS CUANTITATIVO Y CUALITATIVO DE PRODUCTOS DERIVADOS DEL CERDO IBÉRICO. [PubMed]
  33. González-Fernández, J.V.; Díaz De León-Zapata, R.; Lara-Velázquez, I.; Ortega-Gallegos, J. Dispositivo láser semiconductor con puntos cuánticos para emisión en el cercano infrarrojo. Rev. Mex. Física 2018, 65, 43–8. [Google Scholar] [CrossRef]
  34. Russo, N.A.; Noriega, S.B.; Duchowicz, R. Implementación de Sistema Óptico para Grabado de Redes de Bragg en Fibra Óptica. Inf. Tecnológica 2011, 22(2), 121–30. [Google Scholar] [CrossRef]
  35. Garzón, G.; Santacoloma, C.; Galle, B.; Solarte, E. Estrategias De Medición De Gases Volcánicos En Colombia Utilizando Sensores Ópticos Remotos. [PubMed]
  36. Navarro-Henríquez, F. Sensores de fibra óptica FBG para el monitoreo de la salud estructural de los puentes. Rev. Tecnol. En. Marcha 2014, 27(4), 3. [Google Scholar] [CrossRef]
  37. Nunez, I.S.; Shlyagin, M.G. Cine´tica inicial de formacio´n de rejillas de Bragg en fibras o´pticas esta´ndar. Rev. Mex. Fis. 2017. [Google Scholar]
  38. Dávila, A.O. Simulación de un enlace óptico WDM (Wavelength Division Multiplexing) utilizando POFs (Polymer Optical Fiber) en el espectro de luz visible. 2014, 38. [Google Scholar]
  39. Shao, Y.; Xu, S.; Zheng, X.; Wang, Y.; Xu, W. Optical Fiber LSPR Biosensor Prepared by Gold Nanoparticle Assembly on Polyelectrolyte Multilayer. Sensors 2010, 10(4), 3585–96. [Google Scholar] [CrossRef] [PubMed]
  40. Batista, A.A.C.; Paula, J.O.; Marcondes, C.B. Receptor de Comunicações por Luz Visível (VLC) Usando Antena de Fibra Óptica Plástica. [PubMed]
  41. Tian, M.; Zhang, W.; Huang, W. Review of Random Fiber Lasers for Optical Fiber Sensors. Sensors 2023, 23(20), 8500. [Google Scholar] [CrossRef] [PubMed]
  42. Elsherif, M.; Salih, A.E.; Muñoz, M.G.; Alam, F.; AlQattan, B.; Antonysamy, D.S.; et al. Optical Fiber Sensors: Working Principle, Applications, and Limitations. Adv. Photonics Res. 2022, 3(11), 2100371. [Google Scholar] [CrossRef]
  43. Pospíšilová, M.; Kuncová, G.; Trögl, J. Fiber-Optic Chemical Sensors and Fiber-Optic Bio-Sensors. Sensors 2015, 15(10), 25208–59. [Google Scholar] [CrossRef] [PubMed]
  44. Butt, M.A.; Voronkov, G.S.; Grakhova, E.P.; Kutluyarov, R.V.; Kazanskiy, N.L.; Khonina, S.N. Environmental Monitoring: A Comprehensive Review on Optical Waveguide and Fiber-Based Sensors. Biosensors 2022, 12(11), 1038. [Google Scholar] [CrossRef] [PubMed]
  45. Pallarés-Aldeiturriaga, D.; Roldán-Varona, P.; Rodríguez-Cobo, L.; López-Higuera, J.M. Optical Fiber Sensors by Direct Laser Processing: A Review. Sensors 2020, 20(23), 6971. [Google Scholar] [CrossRef] [PubMed]
  46. Max Born, Emil Wolf. Principles of Optics: Electromagnetic Theory of Propagation, Interference and Diffraction of Light [Internet]. 6.a ed. Elsevier; 2013. 836 p. Available online: https://books.google.com.mx/books?id=HY-GDAAAQBAJ&dq=Born+M,+Wolf+E.+Principles+of+Optics.+Cambridge:+Cambridge+University+Press%3B+1999.&lr=&hl=es&source=gbs_navlinks_s.
  47. Karnieli, A.; Rivera, N.; Arie, A.; Kaminer, I. The coherence of light is fundamentally tied to the quantum coherence of the emitting particle. Sci. Adv. 2021, 47 7(18), eabf8096. [Google Scholar] [CrossRef] [PubMed]
  48. Manojlović, L.M.; Živanov, M.B.; Slankamenac, M.P.; Bajić, J.S.; Stupar, D.Z. High-speed and high-sensitivity displacement measurement with phase-locked low-coherence interferometry. Appl. Opt. 2012, 51(19), 4333. [Google Scholar] [CrossRef] [PubMed]
  49. Zheng, J. Coherence analysis of optical frequency-modulated continuous-wave interference. Appl. Opt. 2006, 45(16), 3681. [Google Scholar] [CrossRef] [PubMed]
  50. Yeh, H.C.; Goh, C.F.; Kong, T.F.; Chen, I.M. Fiber-Optic Vibration Measurement for Low Refractive-Index Media Using Wavefront Splitting Interferometry. Int. J. Optomechatronics 2008, 2(1), 32–41. [Google Scholar] [CrossRef]
  51. Volkov, P.; Bobrov, A.; Vyazankin, O.; Gorshkov, A.; Goryunov, A.; Lemeshevskaya, G.; et al. Low-Coherence Integrated Optical Interferometer for Fibre Optic Sensors. Sensors 2024, 25(1), 116. [Google Scholar] [CrossRef] [PubMed]
  52. Lee, B.H.; Kim, Y.H.; Park, K.S.; Eom, J.B.; Kim, M.J.; Rho, B.S.; et al. Interferometric Fiber Optic Sensors. Sensors 2012, 52 12(3), 2467–86. [Google Scholar] [CrossRef] [PubMed]
  53. Wang, J.; Yan, J.; Ding, Y.; Lu, Y.; Jiang, J.; Wan, H.; et al. Fiber-wireless sensor system based on a power-over-fiber technique. Opt. Eng. 2015, 55(3), 031104. [Google Scholar] [CrossRef]
  54. Duque, W.S.; Rodríguez Díaz, C.A.; Leal-Junior, A.G.; Frizera, A. Fiber-Optic Hydrophone Based on Michelson’s Interferometer with Active Stabilization for Liquid Volume Measurement. Sensors 2022, 22(12), 4404. [Google Scholar] [CrossRef] [PubMed]
  55. Chen, S.S.; Shiue, S.T. Theoretical analysis of the interfacial-shear-stress induced delamination of polymeric coatings from the glass fibers in double-coated optical fibers during temperature cycling. Opt. Fiber Technol. 2006, 12(3), 268–75. [Google Scholar] [CrossRef]
  56. Culshaw, B.; Kersey, A. Fiber-Optic Sensing: A Historical Perspective. J. Light Technol. 2008, 26(9), 1064–78. [Google Scholar] [CrossRef]
  57. Homola, J. Surface Plasmon Resonance Sensors for Detection of Chemical and Biological Species. Chem. Rev. 2008, 108(2), 462–93. [Google Scholar] [CrossRef] [PubMed]
  58. Lobry, M.; Fasseaux, H.; Loyez, M.; Chah, K.; Goormaghtigh, E.; Wattiez, R.; et al. Plasmonic Fiber Grating Biosensors Demodulated Through Spectral Envelopes Intersection. J. Light Technol. 2021, 39, 7288–95. [Google Scholar] [CrossRef]
  59. Klantsataya, E.; Jia, P.; Ebendorff-Heidepriem, H.; Monro, T.; François, A. Plasmonic Fiber Optic Refractometric Sensors: From Conventional Architectures to Recent Design Trends. Sensors 2016, 17(1), 12. [Google Scholar] [CrossRef] [PubMed]
  60. Andrés, M.V.; Cruz, J.L.; Díez, A.; Silvestre, E.; Andrés, P.; Cuadrado, C.; et al. Fibras de cristal fotónico y dispositivos de fibra óptica: fabricación, modelización y aplicaciones. [CrossRef]
  61. Russell, P. Photonic Crystal Fibers. Science 2003, 299(5605), 358–62. [Google Scholar] [CrossRef] [PubMed]
  62. Knight, J.C. Photonic crystal fibres. Nature 2003, 424(6950), 847–51. [Google Scholar] [CrossRef] [PubMed]
  63. Rindorf, L.; Bang, O. Highly sensitive refractometer with a photonic-crystal-fiber long-period grating. Opt. Lett. 2008, 33(6), 563. [Google Scholar] [CrossRef] [PubMed]
  64. Cordeiro, C.M.B.; Franco, M.A.R.; Chesini, G.; Barretto, E.C.S.; Lwin, R.; Brito Cruz, C.H.; et al. Microstructured-core optical fibre for evanescent sensing applications. Opt. Express 2006, 14(26), 13056. [Google Scholar] [CrossRef] [PubMed]
  65. Hassan, H.U.; Janting, J.; Aasmul, S.; Bang, O. Polymer Optical Fiber Compound Parabolic Concentrator fiber tip based glucose sensor: in-Vitro Testing. IEEE Sens. J. 2016, 1–1. [Google Scholar] [CrossRef]
  66. Natesan, A.; Govindasamy, K.P.; Gopal, T.R.; Dhasarathan, V.; Aly, A.H. Tricore photonic crystal fibre based refractive index sensor for glucose detection. IET Optoelectron 2019, 13(3), 118–23. [Google Scholar] [CrossRef]
  67. Keiser G. Fiber Optic Communications [Internet]. Singapore: Springer Singapore; 2021 [citado 19 de junio de 2026]. Available online: https://link.springer.com/10.1007/978-981-33-4665-9. [CrossRef]
  68. Saleh, B.E.A.; Teich, M.C. Fundamentals of Photonics [Internet], 1.a ed.; Wiley, 1991; Available online: https://onlinelibrary.wiley.com/doi/book/10.1002/0471213748.
  69. Kopelman, R.; Tan, W.; Shi, Z.Y. Nanometer optical fiber pH sensor; Lieberman, R.A., Ed.; Boston, MA, 1993 [citado 27 de diciembre de 2025; pp. 157–62. Available online: http://proceedings.spiedigitallibrary.org/proceeding.aspx?articleid=1001215. [CrossRef]
  70. Arroyo, J. Magneto-optic current sensor with Faraday mirror for linear birefringence compensation. Opt. Pura Apl. 2012, 45(4), 497–508. [Google Scholar] [CrossRef]
  71. Lozano-Hernández, T.; Jáuregui-Vázquez, D.; Estudillo-Ayala, J.M.; Diaz-Cervantes, E.; Álvarez-Chavez, J.A.; Sierra-Hernández, J.M.; et al. Phase signal analysis for high-sensitive temperature fiber-optic external Fabry-Perot-cavity sensor. Rev. Mex. Física 2024, 70. [Google Scholar] [CrossRef]
  72. Jauregui-Vazquez, D.; Herrera-Piad, L.A.; Tentori, D.; Castro-Toscano, J.D.; Escalante-Sanchez, K.C.; Gallegos-Arellano, E.; et al. “Visible range curvature fiber-optic sensor with low strain-temperature dependence”. Opt. Commun. 2024, 563, 130601. [Google Scholar] [CrossRef]
  73. Zhang, Z.; Zhang, H.; Hou, L.; Jia, D.; Yao, K.; Meng, Q.; et al. Highly sensitive fiber-optic chemical pH sensor based on surface modification of optical fiber with ZnCdSe/ZnS quantum dots. Anal. Chim. Acta 2024, 1294, 342281. [Google Scholar] [CrossRef] [PubMed]
  74. Ospino-Manjarres, K. Study of machine learning techniques for robotic finger monitoring using image based macro-bending fiber optic sensor. Opt. Pura Apl. 2025, 58(1). [Google Scholar] [CrossRef]
  75. Kawabata, Y.; Tsuchida, K.; Imasaka, T.; Ishibashi, N. Fiber-Optic pH Sensor with Monolayer Indicator. Anal. Sci. 1987, 3(1), 7–9. [Google Scholar] [CrossRef]
  76. Wolthuis, R.; McCrae, D.; Saaski, E.; Hartl, J.; Mitchell, G. Development of a medical fiber-optic pH sensor based on optical absorption. IEEE Trans. BioMed Eng. 1992, 39(5), 531–7. [Google Scholar] [CrossRef] [PubMed]
  77. Del Pilar Taboada Sotomayor, M.; De Paoli, M.A.; De Oliveira, W.A. Fiber-optic pH sensor based on Poly(o-methoxyaniline). Anal. Chim. Acta 1997, 353(2-3), 275–80. [Google Scholar] [CrossRef]
  78. Ganesh, A.B.; Radhakrishnan, T.K. Fiber-Optic pH Sensor. Fiber Integr. Opt. 2006, 25(6), 403–9. [Google Scholar] [CrossRef]
  79. Sharma, N.; Gupta, B.D. Fabrication and Characterization of a Fiber-Optic pH Sensor for the pH Range 2 to 13. Fiber Integr. Opt. 2004, 23(4), 327–35. [Google Scholar] [CrossRef]
  80. Singh, S.; Gupta, B.D. Fabrication and characterization of a surface plasmon resonance based fiber optic sensor using gel entrapment technique for the detection of low glucose concentration. Sens. Actuators B Chem. 2013, 177, 589–95. [Google Scholar] [CrossRef]
  81. Mishra, S.K.; Gupta, B.D. Surface plasmon resonance based fiber optic pH sensor utilizing Ag/ITO/Al/hydrogel layers. The Analyst 2013, 138(9), 2640. [Google Scholar] [CrossRef] [PubMed]
  82. Raoufi, N.; Surre, F.; Rajarajan, M.; Sun, T.; Grattan, K.T.V. Fiber Optic pH Sensor Using Optimized Layer-by-Layer Coating Approach. IEEE Sens. J. 2014, 14(1), 47–54. [Google Scholar] [CrossRef]
  83. Zhao, F.; Kim, I.; Kim, J. Fabrication of the Optical Fiber pH Sensor Based on CdSe/ZnS Quantum Dot. J. Nanosci. Nanotechnol. 2014, 14(8), 5650–3. [Google Scholar] [CrossRef] [PubMed]
  84. Zolkapli, M.; Saharudin, S.; Herman, S.H.; Abdullah, W.F.H. A Numerical Analysis of Various pH Level for Fiber Optic pH Sensor Based on Bromophenol Blue in Silica. Int. J. Electr. Electron Syst. Res. IEESR 2019, 9(1), 18. [Google Scholar] [CrossRef]
  85. Mahdi, B.R.; AL-Attabi, H.D.; Salman, S.D. MANUFACTURE OF FIBER OPTIC SENSORS TO MEASURE THE PH WATER. 2016, Vol. 5 5(9). [Google Scholar]
  86. Yuan, Y.; Yang, X.; Gong, D.; Liu, F.; Hu, W.; Cai, W.; et al. Investigation for terminal reflection optical fiber SPR glucose sensor and glucose sensitive membrane with immobilized GODs. Opt. Express 2017, 25(4), 3884. [Google Scholar] [CrossRef] [PubMed]
  87. Deng, S.; McAuliffe, M.A.P.; Salaj-Kosla, U.; Wolfe, R.; Lewis, L.; Huyet, G. A pH sensing system using fluorescence-based fibre optical sensor capable of small volume sample measurement; Soskind, Y.G., Olson, C., Eds.; San Francisco, California, United States, 2017 [citado 24 de diciembre de 2025; p. 101101C. Available online: http://proceedings.spiedigitallibrary.org/proceeding.aspx?doi=10.1117/12.2250163.
  88. Gauthier-Manuel, B.; Kateklum, R.; Wacogne, B. Calibration Free and Fluorescein Based Fiber Optic pH Sensor for Clinical Applications. In 2018 IEEE SENSORS [Internet]; IEEE: New Delhi, 2018 [citado 26 de diciembre de 2025; pp. 1–4. Available online: https://ieeexplore.ieee.org/document/8630296/.
  89. M. Gutierrez-Rivera. Fiber Optic Fabry-Perot Micro-Displacement Sensor Based on Low-Cost Polymer Film. En. 2020. Disponible en: file:///C:/Users/anaya/Downloads/483517850.pdf.
  90. Gutierrez-Rivera, M.; Jauregui-Vazquez, D.; Sierra-Hernandez, J.M.; Garcia-Mina, D.F.; Lopez-Dieguez, Y.; Estudillo-Ayala, J.M.; et al. Low-pressure fiber-optic sensor by polyester Fabry-Perot cavity and its phase signal processing analysis. Sens. Actuators Phys. 2020, 315, 112338. [Google Scholar] [CrossRef]
  91. Hameed Kareem Z. Development and characterization sensitivity of optical fibre pH sensor for industrial application. J. Phys. Conf. Ser. 2020, 1484(1), 012020. [CrossRef]
  92. Islam, S. Fast responsive anatase nanoparticles coated fiber optic pH sensor. J. Alloys Compd. 2021, 850, 156246. [Google Scholar] [CrossRef]
  93. Jauregui-Vazquez, D.; Gutierrez-Rivera, M.E.; Garcia-Mina, D.F.; Sierra-Hernandez, J.M.; Gallegos-Arellano, E.; Estudillo-Ayala, J.M.; et al. Low-pressure and liquid level fiber-optic sensor based on polymeric Fabry–Perot cavity. Opt. Quantum Electron 2021, 53(5), 237. [Google Scholar] [CrossRef] [PubMed]
  94. Jauregui-Vazquez, D.; Lozano-Sotomayor, P.; Mejía-Benavides, J.E.; Díaz-Cervantes, E. Binding Analysis of Functionalized Multimode Optical-Fiber Sandwich-like Structure with Organic Polymer and Its Sensing Application for Humidity and Breath Monitoring. Biosensors 2021, 11(9), 324. [Google Scholar] [CrossRef] [PubMed]
  95. Chen, W.H.; Dillon, W.D.N.; Armstrong, E.A.; Moratti, S.C.; McGraw, C.M. Self-referencing optical fiber pH sensor for marine microenvironments. Talanta 2021, 225, 121969. [Google Scholar] [CrossRef] [PubMed]
  96. Wei, X.; Yan, H.; Liao, N.; Ma, L.; He, L.; Hou, H.; et al. A visible-light spectral demodulation system for fiber-optic SiC Fabry-Perot sensors. Optik 2022, 251, 168441. [Google Scholar] [CrossRef]
  97. Kumar, R.; Nguyen, H.; Rente, B.; Tan, C.; Sun, T.; Grattan, K.T.V. A Portable ‘Plug-and-Play’ Fibre Optic Sensor for In-Situ Measurements of pH Values for Microfluidic Applications. Micromachines 2022, 13(8), 1224. [Google Scholar] [CrossRef] [PubMed]
  98. Goldstein, S.R.; Peterson, J.I.; Fitzgerald, R.V. A Miniature Fiber Optic pH Sensor for Physiological Use. J. Biomech. Eng. 1980, 102(2), 141–6. [Google Scholar] [CrossRef] [PubMed]
  99. Hao, T.; Xing, X.; Liu, C.C. A pH sensor constructed with two types the configuration and the initial results. [CrossRef]
  100. Thomas Lee, S.; Aneeshkumar, B.; Radhakrishnan, P.; Vallabhan, C.P.G.; Nampoori, V.P.N. A microbent fiber optic pH sensor. Opt. Commun. 2002, 205(4-6), 253–6. [Google Scholar] [CrossRef]
  101. Binu, S.; Mahadevan Pillai, V.P.; Pradeepkumar, V.; Padhy, B.B.; Joseph, C.S.; Chandrasekaran, N. Fibre optic glucose sensor. Mater. Sci. Eng. C 2009, 29(1), 183–6. [Google Scholar] [CrossRef]
  102. Lomer, M.; Lazaro, J.M.; Quintela, M.A.; Madruga, F.; Conde, O.; Mirapeix, J.; et al. Medida del nivel de líquidos basado guías de onda metálicas huecas y fibras ópticas plásticas. [PubMed]
  103. Liehr, S.; Lenke, P.; Wendt, M.; Krebber, K.; Seeger, M.; Thiele, E.; et al. Polymer Optical Fiber Sensors for Distributed Strain Measurement and Application in Structural Health Monitoring. IEEE Sens. J. 2009, 9(11), 1330–8. [Google Scholar] [CrossRef]
  104. Souza JAM, Ribeiro RM, Xavier OS, Barbero APL, Mosso MM. Dispositivos Optoeletrônicos para Detecção e Transmissão de Sinais em HF/VHF via Fibra Óptica Polimérica na Área de Defesa. 1983.
  105. Rovati, L.; Fabbri, P.; Ferrari, L.; Pilati, F. Plastic Optical Fiber pH Sensor Using a Sol-Gel Sensing Matrix. In Fiber Optic Sensors [Internet]. InTech; Moh, Yasin, Ed.; 2012 [citado 27 de diciembre de 2025; Available online: http://www.intechopen.com/books/fiber-optic-sensors/plastic-optical-fiber-ph-sensor-using-a-sol-gel-sensing-matrix.
  106. Schyrr, B.; Pasche, S.; Scolan, E.; Ischer, R.; Ferrario, D.; Porchet, J.A.; et al. Development of a polymer optical fiber pH sensor for on-body monitoring application. Sens. Actuators B Chem. 2014, 194, 238–48. [Google Scholar] [CrossRef]
  107. Verma, R.; Gupta, B.D. A novel approach for simultaneous sensing of urea and glucose by SPR based optical fiber multianalyte sensor. The Analyst 2014, 139(6), 1449. [Google Scholar] [CrossRef] [PubMed]
  108. Ferreira, L.; Simões, P.; Carvalho, R.S.; Lopes, P.; Ferreira, M. Design and characterization of a plastic optical fiber pH sensor; Martins Costa, M.F.P.C., Ed.; Porto, Portugal, 2013 [citado 5 de enero de 2026; p. 8785FA. Available online: http://proceedings.spiedigitallibrary.org/proceeding.aspx?doi=10.1117/12.2027505. [CrossRef]
  109. Qiu, H.W.; Xu, S.C.; Jiang, S.Z.; Li, Z.; Chen, P.X.; Gao, S.S.; et al. A novel graphene-based tapered optical fiber sensor for glucose detection. Appl. Surf. Sci. 2015, 329, 390–5. [Google Scholar] [CrossRef]
  110. Islam, S.; Rahman, R.A.; Othaman, Z.B.; Riaz, S.; Naseem, S. Synthesis and characterization of multilayered sol–gel based plastic-clad fiber optic pH sensor. J. Ind. Eng. Chem. 2015, 23, 140–4. [Google Scholar] [CrossRef]
  111. Tiangco, C.; Fon, D.; Sardesai, N.; Kostov, Y.; Sevilla, F.; Rao, G.; et al. Fiber optic biosensor for transdermal glucose based on the glucose binding protein. Sens. Actuators B Chem. 2017, 242, 569–76. [Google Scholar] [CrossRef]
  112. Obrovski, B.; Bajić, J.; Mihajlović, I.; Vojinović Miloradov, M.; Batinić, B.; Živanov, M. Colorimetric fiber optic probe for measurement of chemical parameters in surface water. Sens. Actuators B Chem. 2016, 228, 168–73. [Google Scholar] [CrossRef]
  113. Yunianto, M.; Eka, D.; Permata, A.N.; Ariningrum, D.; Wahyuningsih, S.; Marzuki, A. Development and Testing of a Plastic Optical Fiber Grating Biosensor for Detection of Glucose in the Blood. IOP Conf. Ser. Mater. Sci. Eng. 2017, 176, 012010. [Google Scholar] [CrossRef]
  114. Zhao, M.; Dai, L.; Zhong, N.; Wang, Z.; Chen, M.; Li, B.; et al. Wet etching technique for fabrication of a high-quality plastic optical fiber sensor. Appl. Opt. 2017, 56(31), 8845. [Google Scholar] [CrossRef] [PubMed]
  115. Azkune, M.; Frosch, T.; Arrospide, E.; Aldabaldetreku, G.; Bikandi, I.; Zubia, J.; et al. Liquid-Core Microstructured Polymer Optical Fiber as Fiber-Enhanced Raman Spectroscopy Probe for Glucose Sensing. J. Light Technol. 2019, 37(13), 2981–8. [Google Scholar] [CrossRef]
  116. Moradi, V.; Akbari, M.; Wild, P. A fluorescence-based pH sensor with microfluidic mixing and fiber optic detection for wide range pH measurements. Sens. Actuators Phys. 2019, 297, 111507. [Google Scholar] [CrossRef]
  117. Souza, I.L.G.D.; Rodriguez-Esquerre, V.F. Wavelength-Selective Near Unity Absorber Based on Fabry-Pérot Nanoresonators. J. Microw. Optoelectron Electromagn. Appl. 2021, 20(2), 219–27. [Google Scholar] [CrossRef]
  118. Filoteo-Razo, J.; Vera-Duarte, O.; Estudillo-Ayala, J.; Hernandez-Garcia, J.; Jauregui-Vazquez, D.; Martinez-Angulo, J.; et al. U-Shaped Plastic Fiber Optic Sensor for Measuring Adulteration in Liquids via RGB Color Changes. IEEE Sens. Lett. 2021, 5(12), 1–4. [Google Scholar] [CrossRef]
  119. Leal-Junior, A.; Lopes, G.; Macedo, L.C.; Duque, W.; Frizera, A.; Marques, C. Heterogeneous Optical Fiber Sensor System for Temperature and Turbidity Assessment in Wide Range. Biosensors 2022, 12(11), 1041. [Google Scholar] [CrossRef] [PubMed]
  120. Lomer, 120 M. NUEVO SENSOR DE DESPLAZAMIENTO BASADO EN REDES DE DIFRACCIÓN UTILIZANDO FIBRAS ÓPTICAS PLÁSTICAS. En. Available online: https://repositorio.unican.es/xmlui/bitstream/handle/10902/2522/Nuevo%20sensor.pdf?sequence=1&isAllowed=y.
  121. Yunus, M. U-bend Optical Fiber to Determine Characteristics of pH Sensor. J. Teor. Dan Apl. Fis. 2023, 11(01), 23–8. [Google Scholar] [CrossRef]
  122. Elsherif, M.; Alam, F.; Salih, A.E.; Wang, X.; Corridon, P.R.; Ramadi, K.B.; et al. Fiber-optic probes for real-time pH monitoring. Sens. Diagn. 2024, 3(5), 827–38. [Google Scholar] [CrossRef]
  123. Liang, J.; Yang, L.; Ye, Z.; Tang, Y.; Ouyang, H.; Yang, G.; et al. CdSe/ZnS quantum dots-doped polymer optical fiber microprobe for pH sensing. Opt. Express 2025, 33(2), 2475. [Google Scholar] [CrossRef] [PubMed]
  124. Alonso, A.; Aldabaldetreku, G.; Martínez, J. Diseño de un sistema automático para la caracterización de la atenuación y dispersión en fibras ópticas de plástico. [PubMed]
  125. Parola, I.; Ayesta, I.; Illarramendi, M.A. Amplificación de luz en fibras de plástico dopadas: cálculo de ganancias ópticas. [PubMed]
  126. Instituto Politécnico Nacional - SEPI-ESIME, Alvarado-Noguez ML, Cano-Europa E, Instituto Politécnico Nacional- ENCB, Franco-Colín M, Instituto Politécnico Nacional- ENCB, et al. Obtaining and Analysis of Optical Absorption Spectrum of Fisher Rat Blood with Hepatic Damage by Photoacoustic Spectroscopy. Rev. Mex. Ing. Bioméd 2017, 38(1), 357–62. [CrossRef]
  127. Rubio Sandoval, J.I. Sistema opto-electrónico para la adquisición de espectros ópticos en la región visible mediante el uso de una Raspberry Pi. 03 Julio 2018. 3 de julio de 2018, 9. [Google Scholar]
  128. Bartoli, 128. Julio R. Filmes Ópticos Poliméricos Fluorados com Índice de Refração Gradual. En. Available online: https://www.scielo.br/j/po/a/SM97gpvs4SSdvsNj5zzDW4C/?format=pdf&lang=pt.
  129. Ajil, A.H.; Ahmed, N.M.; Yam, F.K.; Zango, Z.U.; Wadi, I.A.; M. Binzowaimil, A.; et al. Enhancing Methyl Orange Degradation with Laser-Generated ZnO and Ce-Doped ZnO Nanoparticles. Appl. Sci. 2023, 13(21), 11857. [Google Scholar] [CrossRef]
  130. Machado M, Ribeiro R, Xavier O, Barbero A, Zanco W. Atenuador Óptico Variável Para Fibras Ópticas Plásticas (POF-VOA) com Controle Foto-Cromático. En: Anais de XXIX Simpósio Brasileiro de Telecomunicações [Internet]. Sociedade Brasileira de Telecomunicações; 2011 [citado 27 de agosto de 2025]. Available online: http://biblioteca.sbrt.org.br/articles/1838. [CrossRef]
  131. Oliveira R, Zanon M, Campos L, Ribeiro R, Silva V. Demultiplexadores para WDM sobre fibras ópticas plásticas com base em filtros gel. En: Anais de XXXV Simpósio Brasileiro de Telecomunicações e Processamento de Sinais [Internet]. Sociedade Brasileira de Telecomunicações; 2017 [citado 27 de agosto de 2025]. Available online: http://biblioteca.sbrt.org.br/articles/509. [CrossRef]
  132. Lomer, M.; Contreras, K.; Rueda, J.C.; Galindez, C.; Lopez-Higuera, J.M. Alarma de fibra óptica para líquidos inflamables basado en la sensibilidad termo-óptica del PNIPAAm. [PubMed]
  133. Souza JAM, Ribeiro RM, Xavier OS, Barbero APL, Mosso MM. Dispositivos Optoeletrônicos para Detecção e Transmissão de Sinais em HF/VHF via Fibra Óptica Polimérica na Área de Defesa. 1983.
  134. Zhao, J.; Luo, X.; Liu, H. An Airborne Visible Light Lidar’s Methodology for Clear Air Turbulence Detection Based on Weak Optical Signal. Photonics 2023, 10(11), 1185. [Google Scholar] [CrossRef]
  135. Wang, X.-D.; Wolfbeis, O.S. Fiber-Optic Chemical Sensors and Biosensors (2015–2019). Anal. Chem. 2020, vol. 92(no. 1), 397–430. [Google Scholar] [CrossRef] [PubMed]
  136. Wen, Z.; Guan, Z.; Dong, J.; Li, H.; Song, Y. C. A Review of Sensitivity Enhancement in Interferometer-Based Fiber Sensors. Sensors 2022, vol. 22(no. 7), Art. no. 2506. [Google Scholar] [CrossRef] [PubMed]
  137. Caucheteur, 137 C.; Guo, T.; Albert, J. Review of plasmonic fiber optic biochemical sensors: Improving the limit of detection. Anal. Bioanal. Chem. 2015, vol. 407(no. 14), 3883–3897. [Google Scholar] [CrossRef] [PubMed]
  138. Steinegger, 138; Wolfbeis, O. S.; Borisov, S. M. Optical Sensing and Imaging of pH Values: Spectroscopies, Materials, and Applications. Chem. Rev. 2020, vol. 120(no. 22), 12357–12489. [Google Scholar] [CrossRef] [PubMed]
  139. Wang, 139 K.; Dong, X.; Köhler, M. H.; Kienle, P.; Bian, Q.; Jakobi, M.; Koch, A. W. Advances in Optical Fiber Sensors Based on Multimode Interference (MMI): A Review. IEEE Sens. J. 2021, vol. 21(no. 1), 132–142. [Google Scholar] [CrossRef]
  140. Moradi, 140 V.; et al. A fluorescence-based pH sensor with microfluidic mixing and fiber optic detection for wide range pH measurements. Sens. Actuators A Phys. 2019, vol. 297, Art.(no. 111507). [Google Scholar] [CrossRef]
  141. Yu, 141 X.; Chung, Y. J.; Lee, J. H. In-Line Fiber Optic Interferometric Sensors in Single-Mode Fibers. Sensors 2012, vol. 12(no. 8), 10430–10449. [Google Scholar] [CrossRef] [PubMed]
Figure 1. Diagram of constructive interference of light waves (53).
Figure 1. Diagram of constructive interference of light waves (53).
Preprints 240007 g001
Figure 2. A fibre-optic hydrophone (FOH) based on a Michelson interferometer (61).
Figure 2. A fibre-optic hydrophone (FOH) based on a Michelson interferometer (61).
Preprints 240007 g002
Figure 3. Schematic diagram of a fibre-optic Mach-Zehnder interferometer (53).
Figure 3. Schematic diagram of a fibre-optic Mach-Zehnder interferometer (53).
Preprints 240007 g003
Figure 4. Schematic of a fibre-optic Fabry-Pérot interferometer, with a detailed view of the cavity (55).
Figure 4. Schematic of a fibre-optic Fabry-Pérot interferometer, with a detailed view of the cavity (55).
Preprints 240007 g004
Figure 5. Experimental configuration of a fibre-optic Sagnac interferometer (53).
Figure 5. Experimental configuration of a fibre-optic Sagnac interferometer (53).
Preprints 240007 g005
Figure 6. (a) Glucose sensor in operation. (b) Illustration of the assay’s chemical process and FRET detection principle, showing (c) low and high intensities associated with 40 mg/dL and 400 mg/dL, respectively (65).
Figure 6. (a) Glucose sensor in operation. (b) Illustration of the assay’s chemical process and FRET detection principle, showing (c) low and high intensities associated with 40 mg/dL and 400 mg/dL, respectively (65).
Preprints 240007 g006
Figure 7. Diagram of the optical fibre at different stages (39).
Figure 7. Diagram of the optical fibre at different stages (39).
Preprints 240007 g007
Figure 9. Diagram of the Low-Coherence External Fabry–Perot Interferometer with Capillary (71).
Figure 9. Diagram of the Low-Coherence External Fabry–Perot Interferometer with Capillary (71).
Preprints 240007 g009
Figure 10. Mach–Zehnder interferometric structure in optical fibre and operating principle based on a defective splice that introduces a mismatch in the cross-section between the 630HP and 460HP fibres (72).
Figure 10. Mach–Zehnder interferometric structure in optical fibre and operating principle based on a defective splice that introduces a mismatch in the cross-section between the 630HP and 460HP fibres (72).
Preprints 240007 g010
Figure 11. Diagram of the experimental system, comprising a broadband LED source, a fibre-optic MZI, a translation stage and a spectrometer (72).
Figure 11. Diagram of the experimental system, comprising a broadband LED source, a fibre-optic MZI, a translation stage and a spectrometer (72).
Preprints 240007 g011
Figure 12. Schematic of the optical fibre pH sensor based on ZnCdSe/ZnS quantum dots and evanescent-wave detection (73).
Figure 12. Schematic of the optical fibre pH sensor based on ZnCdSe/ZnS quantum dots and evanescent-wave detection (73).
Preprints 240007 g012
Figure 13. Schematic representation of the curvature detection setup, used to study variations in wavelength and spectral intensity when curvature is applied. (74).
Figure 13. Schematic representation of the curvature detection setup, used to study variations in wavelength and spectral intensity when curvature is applied. (74).
Preprints 240007 g013
Figure 14. Schematic of the pH optode based on PoAnis/TSA adsorbed onto polyethylene (77).
Figure 14. Schematic of the pH optode based on PoAnis/TSA adsorbed onto polyethylene (77).
Preprints 240007 g014
Figure 15. Diagram of the optical fibre probes in straight and U-shaped configurations (82).
Figure 15. Diagram of the optical fibre probes in straight and U-shaped configurations (82).
Preprints 240007 g015
Figure 16. Diagram of the straight and U-shaped curved probes (82).
Figure 16. Diagram of the straight and U-shaped curved probes (82).
Preprints 240007 g016
Figure 17. Optical fibre probe for pH sensing (84).
Figure 17. Optical fibre probe for pH sensing (84).
Preprints 240007 g017
Figure 18. Experimental setup of the photoacoustic spectrometer (89).
Figure 18. Experimental setup of the photoacoustic spectrometer (89).
Preprints 240007 g018
Figure 19. Schematic of the experimental setup for the measurements (91).
Figure 19. Schematic of the experimental setup for the measurements (91).
Preprints 240007 g019
Figure 20. FESEM images of (a) the NPs matrix and (b) the PR/NPs matrix (92).
Figure 20. FESEM images of (a) the NPs matrix and (b) the PR/NPs matrix (92).
Preprints 240007 g020
Figure 21. Schematic of the interface between the Mylar® polymer film and the multimode optical fibre (93).
Figure 21. Schematic of the interface between the Mylar® polymer film and the multimode optical fibre (93).
Preprints 240007 g021
Figure 22. Experimental setup (93).
Figure 22. Experimental setup (93).
Preprints 240007 g022
Figure 23. (a) Structure of the optical fibre formed by MMF and NCF, with layer F as the active region. (b) Light intensity propagation pattern in the NCF at a wavelength of 522 nm (94).
Figure 23. (a) Structure of the optical fibre formed by MMF and NCF, with layer F as the active region. (b) Light intensity propagation pattern in the NCF at a wavelength of 522 nm (94).
Preprints 240007 g023
Figure 24. Schematic of the experimental setup for evaluating the humidity response of the functionalised optical fibre sandwich structure (94).
Figure 24. Schematic of the experimental setup for evaluating the humidity response of the functionalised optical fibre sandwich structure (94).
Preprints 240007 g024
Figure 25. Schematic diagram of a Fabry–Pérot pressure sensor based entirely on SiC (96).
Figure 25. Schematic diagram of a Fabry–Pérot pressure sensor based entirely on SiC (96).
Preprints 240007 g025
Figure 26. Schematic diagram of the visible-light spectral demodulation system for SiC Fabry–Pérot sensors (96).
Figure 26. Schematic diagram of the visible-light spectral demodulation system for SiC Fabry–Pérot sensors (96).
Preprints 240007 g026
Figure 27. (a) Coated multimode fibre (core diameter ≈ 1 mm), with an enlarged view of the functionalised area located inside the sensing chamber. (b) Fibres integrated into the microfluidic channel. (c) Top and side views of the system schematics (97).
Figure 27. (a) Coated multimode fibre (core diameter ≈ 1 mm), with an enlarged view of the functionalised area located inside the sensing chamber. (b) Fibres integrated into the microfluidic channel. (c) Top and side views of the system schematics (97).
Preprints 240007 g027
Figure 28. Configurations of two fibre-optic pH sensors (99).
Figure 28. Configurations of two fibre-optic pH sensors (99).
Preprints 240007 g028
Figure 29. Schematic diagram of the experimental setup (100).
Figure 29. Schematic diagram of the experimental setup (100).
Preprints 240007 g029
Figure 30. Diagram of the experimental setup for measuring changes in the refractive index according to concentration (101).
Figure 30. Diagram of the experimental setup for measuring changes in the refractive index according to concentration (101).
Preprints 240007 g030
Figure 31. Liquid level sensor with intensity modulation (102).
Figure 31. Liquid level sensor with intensity modulation (102).
Preprints 240007 g031
Figure 32. Diagram of the fibre-optic pH sensor and its experimental setup (106).
Figure 32. Diagram of the fibre-optic pH sensor and its experimental setup (106).
Preprints 240007 g032
Figure 33. Diagram of the experimental setup used to acquire surface plasmon resonance (SPR) spectra and evaluate the sensor’s performance (107).
Figure 33. Diagram of the experimental setup used to acquire surface plasmon resonance (SPR) spectra and evaluate the sensor’s performance (107).
Preprints 240007 g033
Figure 34. Microscopic images of the indicator-functionalised hybrid matrix, obtained at 5× magnification (110).
Figure 34. Microscopic images of the indicator-functionalised hybrid matrix, obtained at 5× magnification (110).
Preprints 240007 g034
Figure 35. a) Schematic of the glucose biosensor based on an optical fibre, with GBP-BADAN immobilised on Ni-NTA agarose beads. b) Photograph of the optical fibre biosensor (111).
Figure 35. a) Schematic of the glucose biosensor based on an optical fibre, with GBP-BADAN immobilised on Ni-NTA agarose beads. b) Photograph of the optical fibre biosensor (111).
Preprints 240007 g035
Figure 36. Block diagram of the developed sensor (112).
Figure 36. Block diagram of the developed sensor (112).
Preprints 240007 g036
Figure 37. Diagram of the light spectrometer configuration (113).
Figure 37. Diagram of the light spectrometer configuration (113).
Preprints 240007 g037
Figure 38. Experimental setup and immersion of the modified end face of the LC-mPOF, with an inset showing the top face focused using Raman microscopy (115).
Figure 38. Experimental setup and immersion of the modified end face of the LC-mPOF, with an inset showing the top face focused using Raman microscopy (115).
Preprints 240007 g038
Figure 39. (a) Schematic illustration of the microfluidic system for pH sensing. (b) Photograph of the microfluidic pH system (116).
Figure 39. (a) Schematic illustration of the microfluidic system for pH sensing. (b) Photograph of the microfluidic pH system (116).
Preprints 240007 g039
Figure 40. Structure of a planar metal–dielectric Fabry-Pérot absorber (117).
Figure 40. Structure of a planar metal–dielectric Fabry-Pérot absorber (117).
Preprints 240007 g040
Figure 41. Diagram showing how a U-shaped plastic optical fibre works, where α represents the acceptance angle, θi the angle of incidence and θc the critical angle (118).
Figure 41. Diagram showing how a U-shaped plastic optical fibre works, where α represents the acceptance angle, θi the angle of incidence and θc the critical angle (118).
Preprints 240007 g041
Figure 42. Experimental configuration for (a) intensity detection, (b) fibre Bragg grating (FBG) and (c) surface plasmon resonance (SPR) (119).
Figure 42. Experimental configuration for (a) intensity detection, (b) fibre Bragg grating (FBG) and (c) surface plasmon resonance (SPR) (119).
Preprints 240007 g042
Figure 43. Schematic of the U-shaped optical fibre-based pH sensor design (121).
Figure 43. Schematic of the U-shaped optical fibre-based pH sensor design (121).
Preprints 240007 g043
Figure 44. Response of neutral red dye dissolved in deionised water at different pH values (122).
Figure 44. Response of neutral red dye dissolved in deionised water at different pH values (122).
Preprints 240007 g044
Figure 45. Schematic diagram of the experimental principle (123).
Figure 45. Schematic diagram of the experimental principle (123).
Preprints 240007 g045
Figure 46. Attenuation measurement system (124).
Figure 46. Attenuation measurement system (124).
Preprints 240007 g046
Figure 47. Dispersion measurement system (124).
Figure 47. Dispersion measurement system (124).
Preprints 240007 g047
Figure 48. Experimental setup for measuring gain using the VSL method (125).
Figure 48. Experimental setup for measuring gain using the VSL method (125).
Preprints 240007 g048
Figure 49. Experimental setup of the photoacoustic spectrometer (126).
Figure 49. Experimental setup of the photoacoustic spectrometer (126).
Preprints 240007 g049
Figure 50. Model of the experimental physical system (127).
Figure 50. Model of the experimental physical system (127).
Preprints 240007 g050
Figure 51. Schematic representation (129).
Figure 51. Schematic representation (129).
Preprints 240007 g051
Figure 52. (a) Experimental setup for the degradation of MO using photocatalysts under UV and solar light; (b) absorption curve of the MO dye (129).
Figure 52. (a) Experimental setup for the degradation of MO using photocatalysts under UV and solar light; (b) absorption curve of the MO dye (129).
Preprints 240007 g052
Figure 53. Experimental setup of the photochromic plastic optical fibre variable optical attenuator (POF-VOA) (130).
Figure 53. Experimental setup of the photochromic plastic optical fibre variable optical attenuator (POF-VOA) (130).
Preprints 240007 g053
Figure 54. Diagram of the demultiplexing system (DEMUX)(131).
Figure 54. Diagram of the demultiplexing system (DEMUX)(131).
Preprints 240007 g054
Figure 55. Diagram of a bidirectional communication system with POF and two wavelengthdivision multiplexing (WDM) channels (131).
Figure 55. Diagram of a bidirectional communication system with POF and two wavelengthdivision multiplexing (WDM) channels (131).
Preprints 240007 g055
Figure 59. Simplified overview of the CAT detection system using airborne LiDAR (133).
Figure 59. Simplified overview of the CAT detection system using airborne LiDAR (133).
Preprints 240007 g059
Table 1. Advantages and disadvantages of types of optical fibre sensors in visible light.
Table 1. Advantages and disadvantages of types of optical fibre sensors in visible light.
Sensor Advantages Disadvantages
Glucose
High precision in biomedical detection; broad visible range
Sensitivity limited to certain wavelengths
Sensor functionalized with carbon nanotubes (CNTs) High sensitivity to nanomaterials; sensitivity significantly improved through doping
Manufacturing cost and difficulty
Turbulence detector
Precision in fluids; industrial use
Limitation to 523 nm; constant calibration
Curvature
Flexibility to accommodate deformation; robustness
Lower accuracy for specific lengths
Temperature
Adequate thermal response; structural monitoring
Reduced sensitivity across a wide range
Absorbent
Basic chemical detection; easy to manufacture Low resolution; limited range
Liquid adulteration
Simple detection of contaminants
Limited sensitivity; frequent adjustments
Capillarity and Damp
Cost-effective environmental monitoring
Reduced accuracy in extreme humidity
pH
Basic response to pH changes; low cost
Narrow range; less effective for complex solutions
Table 2. Comparison of optical fibre sensors in visible ligh.
Table 2. Comparison of optical fibre sensors in visible ligh.
Fibre Type Sensing
Range detection Structure
Sensitivity Ref.
Photonics Glucose 600–750 nm Fluorescence
40 mg/dL y 400 mg/dL (65)
Glucose 440–470 nm Silicon substrate 23,267.3 nm/RIU (66)
SMF pH 488 nm Acrylamide 0.1 pH (69)
Glucose 625-700 nm Gold 13,09 nm/RIU (39)
Measure DC and AC current and magnetic fields 633 nm Linear birefringence SMNQ (70)
Temperature 625 nm Polímero adhesivo UV 5.77 nm/°C (71)
Curvature 460 nm y 630 nm Sandwich-type structure −10.44 nm·m⁻¹ (72)
pH 500-650 nm Carboxylated ZnCdSe/ZnS quantum dots 0.139 pH-1 (73)
Curvature 470-750 nm N/A N/A (74)
MMF pH 520 nm Fluorescein isothiocyanate (FITC) 4.0–6.9 pH (75)
pH 625–630 nm Sangre 0.01 pH (76)
pH 400-600 nm p-Toluenesulfonic acid 8 pH (77)
pH 300-1100 nm Congo red and Neutral red 4.2-6.3 y 4.1-9.0 pH (78)
pH 600 nm Ethyl violet dye with sol-gel 2 y 13 pH (79)
Glucose 656.9-679.50 nm Silver and silicon films 0,14 nm/(mg/dL) (80)
pH 550-800 nm Metal coatings 12.5 nm/pH. (81)
pH 497 nm Layer by layer (bright yellow indicator and poly(allylamine hydrochloride)) 148.7nm/pH (82)
pH 467–605 nm Carboxylated CdSe/ZnS quantum dots 0.4-0.5 nm/a.u. (83)
pH 470-850 nm Bromophenol blue (BPB)-doped sol–gel 2.4 pH (84)
pH 655.4 nm Methyl red 4-12 pH (85)
Glucose 550-700 nm Polyacrylamide gel 0,14 nm/(mg/dL). (86)
pH 465 nm Bromocresol purple 5.3- 8.7 pH (87)
pH 450-700 nm Fluorescence 0.1 pH (88)
Microdisplacements
552.1 nm Mylar® polymer film 27.84 nm/μm (89)
Pressure 545-565 nm Thin polyester film 3.5 rad/psi (90)
pH 519-523 nm Distilled water containing HCl and NaOH 0.015 y 0.2 pH⁻¹ (91)
pH 454 nm Anatase nanoparticles (TiO₂) 1.83 counts/pH (92)
Low pressure and fluid levels 555-568.78 nm Mylar® membrane 2.49 nm/kPa y 24.5 nm/m (93)
Breathing and Humidity 522 nm (3-aminopropyl)triethoxysilane (APTES) and alginate 3.1288 mV/RH
(94)
pH 460-480 nm Hybrid sol–gel of tetraethoxysilane (TEOS) and dimethyldiethoxysilane (DMDES) ±0.02 pH (95)
Pressure
470-850 nm Silicon carbide (SiC) 0.19357 nm/kPa (96)
pH 4750-770 nm Acrylamidofluorescein fluorescent dye (AAF) 7.5 pH
(97)
POF pH 500-660 nm Phenol red 0.02 pH (98)
pH 558-560 nm Dye (phenol red) 6.0-8.0 pH (99)
pH 589-633 nm Sol-gel (bromocresol purple, bromocresol green and cresol red) 3-11 pH (100)
GlucosE 660 nm N/A 0,0072 V/% (101)
Liquids 660 nm HMW 0.097 At (102)
Deformation 650 Nm POF, OTDR 15×10⁻⁶ K⁻¹. (103)
Electromagnetic Detection 650 nm N/A 5.6 mV/μW (104)
pH 400-800 nm Red phenol with sol–gel 5-8 pH (105)
pH 590 nm Sol-gel (tetraethyl orthosilicate (TEOS) and methyltriethoxysilane (MTES)) 3-9 pH (106)
Glucose 500-800 nm Copper and tin oxide 0–260 mg/dL (107)
pH 565 nm Silica sol–gel (TEOS) N/A (108)
Glucose 628 nm Graphene
29500- 27500 a.u (109)
pH 200-800 nm SiO₂–TiO₂ 3-11 pH (110)
Glucose 366 y 540 nm Ni-NTA agarose beads 2.888 ± 0.08085 (111)
pH 466–634 nm Intrinsic colourimetry of the sample (RGB/HSV). 0.98–0.999 error relativo 2.3–6.2% vs (112)
Glucose 581 nm N/A 81,2 - 235,1 mg/dl (113)
Temperature 500–750 nm Acetic acid 9.10 RIU g/L−1 (114)
Glucose 450 y 500 nm Methyl methacrylate 0 mmol/L- 25 mmol/L (115)
pH 445 nm Trisodium 8-hydroxypyrene-1,3,6-trisulfonate (HPTS) 2.5–9.0 pH (116)
Absorbent 694.8 nm Metal-dieléctrico ±2 nm (117)
Adulteration in liquids 450 y 500 nm RGB photodiodes 0.1, 0.6 y 0.4 bits de 8 bits/% (118)
Temperature and turbidity in liquid samples 680 nm Surface plasmon resonance (SPR) 98,6% y 313,5 nm/RIU (119)
Displacement
660 nm Self-Reference Mechanism 4 mm a 10 mm (120)
pH 450 nm RGB 3.2 µW/pH (121)
pH 400-700 nm Biocompatible synthetic hydrogel 17 nm pH−1 (122)
pH 400-800 nm CdSe/ZnS quantum dots 0.18097 pH⁻¹ (123)
Table 3. Non-sensory support devices in the development of optical fibre sensors.
Table 3. Non-sensory support devices in the development of optical fibre sensors.
Device Technique/Platform Operation Ref.
Alternative spectrometer
Raspberry Pi 3 + SpectraSuite
Wavelength measurement of light sources for single-mode sensor design (124)
Automated measurement system
Mode encoder, monochromator (350–1700)
Measurement of attenuation and scattering in POF (125)
Gain measurement system (VSL) Nd:YAG laser with FOS spectrum
Characterisation of optical amplification in rhodamine-doped fibre -6 (126)
Photoacoustic spectrometer
Photoacoustic spectroscopy (PAS)
Characterisation of optical absorption spectra in blood (127)
Plasma fluorination system
CF₄ + H₂ plasma on PMMA
Modification of the refractive index of thin films (128)
LACBS System Laser CO2 Synthesis of Ce-doped ZnO nanoparticles (129)
POF-VOA Photochromic polymers
LED-controlled variable optical attenuation (130)
WDM demultiplexers (DEMUXs) Diode lasers, gel filters
Wavelength-division multiplexing/demultiplexing in POF (131)
VLC receiver MPO photodiode + blue LED
Visible light communications reception (40)
Electromagnetic detection system Loop antennas with LED and POF
AM/FM band detection in HF/VHF (132)
Thermal alarm system PNIPAAm hydrogel
LCST-based alarm for flammable liquids (133)
LIDAR (CAT) Visible light, 532 nm
Atmospheric turbulence detection (134)
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.
Copyright: This open access article is published under a Creative Commons CC BY 4.0 license, which permit the free download, distribution, and reuse, provided that the author and preprint are cited in any reuse.