Preprint
Article

This version is not peer-reviewed.

Ground-Based Thermal Infrared Imaging of Hyperthermal Springs in a Built Heritage Environment: Radiometric Challenges and Thermal Anomaly Mapping at As Burgas (Ourense, Spain)

Submitted:

21 October 2026

Posted:

22 October 2026

You are already at the latest version

Abstract
Urban hyperthermal springs embedded in historic ensembles are a demanding setting for thermal remote sensing: extreme temperature contrasts, materials of different emissivity within a few metres and vapour along the optical path. This study applies ground-based radiometric infrared thermography to the two monumental fountains of As Burgas (Ourense, Spain), a site protected as a Property of Cultural Interest. The raw sensor values of 67 thermograms acquired with a low-cost smartphone-attached camera were processed with a custom radiometric model, RGB–TIR co-registration, regions of interest, line profiles, anomaly classification and sensitivity analysis. The water reached radiometric temperatures of 61.9 °C at Burga de Arriba and 68.5 °C at Burga de Abaixo (67.4 °C with water emissivity and field conditions, within 0.4–1.1 °C of published spring temperatures). The adjacent masonry was heated by up to 6.8 °C, and anomalies without visible water, such as the drainage network, were detected. Radiometric parameterisation introduced little uncertainty (≤2.5 °C), compared with an underestimation of 6–19 °C caused by spatial resolution in overview images. A replicable protocol for monitoring built hydrothermal heritage is proposed.
Keywords: 
;  ;  ;  ;  ;  ;  ;  ;  
Subject: 
Engineering  -   Other

1. Introduction

Thermal remote sensing is a well-established tool for studying hydrothermal systems. At airborne and satellite scales, thermal infrared (TIR) radiation makes it possible to map the surface temperature anomalies associated with springs and to estimate physical quantities such as heat flux or outflow rate [1]. The advent of unmanned aircraft systems (UAS) has reduced pixel sizes to the decimetre scale and enabled the georeferenced mapping of geothermal fields at a level of detail unattainable from crewed platforms [2]. Between this scale and that of the contact thermometer lies ground-based thermography, which can resolve centimetre-sized features but has been far less studied as a quantitative tool in hydrothermal settings.
In built heritage, infrared thermography has been used for decades as a non-destructive technique to detect moisture, hidden defects, discontinuities and decay in historic masonry [3,4,5]. Previous work has applied ground-based and aerial thermography to the diagnosis of old masonry constructions [6,7]. However, most of these applications are qualitative: they look for thermal patterns rather than absolute temperatures and usually treat water as a decay agent, not as the dominant heat source in the scene.
Moving from qualitative interpretation to quantitative measurement requires controlling several factors: the emissivity of each material, the reflected apparent temperature, atmospheric transmission, the viewing angle and the relationship between the size of the target and the instantaneous field of view of the detector [8,9,10]. ASTM E1933 sets out procedures for measuring and compensating for emissivity [11], but wet surfaces, water films and vapour complicate their application outdoors. In addition, low-cost cameras attached to smartphones are increasingly used for inspection, yet their quantitative limits in high-contrast scenes are poorly documented.
The hydrothermal and heritage literatures rarely intersect. Built hydrothermal environments combine water–masonry thermal contrasts of more than 40 °C, heterogeneous materials within a few metres, moving water films and vapour plumes, and they are often legally protected, which requires non-contact techniques [12]. Studies are lacking that assess, under these conditions, how much of the uncertainty of radiometric measurements arises from parameterisation and how much from acquisition geometry.
This study addresses that gap at As Burgas (Ourense, Spain), an ensemble of urban thermal springs protected as a Property of Cultural Interest (Bien de Interés Cultural, BIC). Its objectives are: (i) to map and quantify the thermal field of two spring outlets with different architectures, Burga de Arriba and Burga de Abaixo; (ii) to assess the uncertainty associated with radiometric parameterisation and compare it with that caused by spatial resolution; and (iii) to propose a replicable protocol for the thermographic monitoring of built hydrothermal heritage. Section 2 describes the study area, equipment and processing; Section 3 presents the results; Section 4 discusses them and proposes the protocol; and Section 5 summarises the conclusions.

2. Materials and Methods

2.1. Study Area

As Burgas is located in the historic centre of Ourense (42°20′05″ N, 7°51′53″ W), about 400 m from the Plaza Mayor [13]. The ensemble of thermal springs and its surroundings was declared a Property of Cultural Interest, in the category of historic site, by Decree 17/2007 [12]. This protection constrains the methodology: any diagnostic technique must be non-invasive and, preferably, free of contact with the masonry.
The springs belong to the Ourense-city geothermal field, a medium-enthalpy, fracture-controlled system developed in fractured granites. A total of 39 outcrops with temperatures of 18–66.3 °C and sodium-bicarbonate waters have been inventoried in the municipality [14,15]. Their composition and behaviour are explained by deep circulation through granite fractures and by the residence time of water in the aquifer [16,17]. The two fountains studied are the hottest in the city: 64.8–65.3 °C at Burga de Arriba and 66.3–67 °C at Burga de Abaixo, located at 119 and 115 m a.s.l., respectively [14,18,19]. The discharge of Burga de Abaixo is much higher than that of Burga de Arriba (of the order of 1–3 L s⁻¹ versus 0.23 L s⁻¹) [14].
Burga de Arriba is a granite masonry body built against a wall, with two spouts about 0.40 m apart (axis to axis) that discharge into ground-level basins. Burga de Abaixo, in neoclassical style, has a 6.85 m wide monumental front of three bodies: the central one houses a niche with a carved column down which the water flows into a stepped basin, and each lateral body has a spout with its own basin. Both are built of granite ashlar with encrustations and oxide stains associated with the water (Figure 2).
The use of the site for bathing is documented at least since the mid-first century BC, including a Roman-period sanctuary devoted to the waters [20,21]. The present monumental configuration dates from the early modern period and the nineteenth century, and the surroundings were redeveloped between the late twentieth and early twenty-first centuries [20]. The thermal pool of the site has remained closed since 2020 [13].
Figure 1. Location of the study area: from the Iberian Peninsula and Galicia to the city of Ourense and, on the orthophoto, the two spring outlets studied within the historic centre: (1) Burga de Abaixo; (2) Burga de Arriba. Base maps adapted from Wikimedia Commons (File:Ourense_in_Spain_(plus_Canarias).svg and File:Situacion_Ourense.PNG; licences as stated on each file page) and Instituto Geográfico Nacional (PNOA orthophoto and base map, CC BY 4.0, © Instituto Geográfico Nacional, scne.es).
Figure 1. Location of the study area: from the Iberian Peninsula and Galicia to the city of Ourense and, on the orthophoto, the two spring outlets studied within the historic centre: (1) Burga de Abaixo; (2) Burga de Arriba. Base maps adapted from Wikimedia Commons (File:Ourense_in_Spain_(plus_Canarias).svg and File:Situacion_Ourense.PNG; licences as stated on each file page) and Instituto Geográfico Nacional (PNOA orthophoto and base map, CC BY 4.0, © Instituto Geográfico Nacional, scne.es).
Preprints 239720 g001
Figure 2. General view of the two spring outlets studied: (a) Burga de Arriba; (b) Burga de Abaixo.
Figure 2. General view of the two spring outlets studied: (a) Burga de Arriba; (b) Burga de Abaixo.
Preprints 239720 g002

2.2. Thermal Imaging Equipment

Thermograms were acquired with a FLIR ONE Gen 3 camera (FLIR Systems, Wilsonville, OR, USA), in its iOS version, connected to a smartphone running that operating system [23]. It is a smartphone-attached thermal module that integrates an uncooled microbolometer and a visible camera. It is an entry-level device: its native thermal resolution is 80 × 60 pixels, with a 17 µm pixel pitch, a spectral range of 8–14 µm and an NETD of 150 mK [23], although the application exports the radiometric matrix interpolated to 640 × 480 pixels together with a 1440 × 1080 pixel visible image (Table 1).
Files were stored as radiometric JPEGs. Besides the displayed image, their APP1 segments contain the raw detector values (encoded as 16-bit PNG), the Planck calibration constants (R1, R2, B, F, O), the atmospheric transmission coefficients, the object parameters in force at acquisition and the alignment parameters between the visible and thermal channels. With a 50° × 38° field of view, the native IFOV is 12 mrad according to the manufacturer [23], equivalent to a pixel of about 1.2 cm on the object per metre of distance. The nominal accuracy is ±3 °C or 5% of the difference between ambient and scene temperature, with the device between 15 and 35 °C [23]. This limitation constrains the measurement of narrow features such as water jets and is explicitly assessed in Section 2.7, Section 3.6 and Section 4.3.

2.3. Data Acquisition

Both springs were surveyed in a single session on 12 April 2025: Burga de Arriba between 17:23:43 and 17:24:24 and Burga de Abaixo between 17:25:23 and 17:27:53 (local time, CEST; UTC + 2). A total of 67 thermograms were acquired, 12 at Burga de Arriba and 55 at Burga de Abaixo. The difference reflects the larger number of spouts and the larger monumental front of Burga de Abaixo, which required more views to cover it. Since both series were acquired less than four minutes apart, ambient conditions can be considered equivalent. All images were taken hand-held, without a tripod, from the paving of each square.
Images were taken in bursts of 2 to 7 consecutive frames with approximately the same framing. Three view types are distinguished at Burga de Arriba: frontal overview, oblique overview and oblique close-up. Seven are distinguished at Burga de Abaixo: frontal overview, vertical overview and vertical closer view of the central fountain, intermediate or oblique views of the central fountain, detail of the crown of the central outlet, and close-ups of each lateral spout. The full classification is given in Section 3.3. All files share the same GNSS position of the paired smartphone (42°20′4.9″ N, 7°51′53.1″ W; 123 m a.s.l.) and record no orientation, so the geotag identifies the site but not the individual position of each image.
All 67 thermograms were processed to obtain maxima by view type and repeatability between consecutive frames. For the region-of-interest analysis, profiles and anomaly maps, a single image was selected at each spring with an objective criterion: within the frontal burst covering all elements (spouts, basins and paving), the frame with the highest RGB–TIR registration correlation (Section 2.5). Frames 20250412T172343 (Burga de Arriba) and 20250412T172608 (Burga de Abaixo) were selected.
Meteorological conditions were obtained from the ten-minute records of the Ourense-Estacións station (ID 10155) of MeteoGalicia [24] (42.3530° N, 7.8779° W; 139 m a.s.l.), located about 2.3 km in a straight line NNW of As Burgas at a similar elevation. It was a rainy day, but rain fell only in the morning, so there was no precipitation during the survey and it had stopped hours before. Between 17:20 and 17:30, air temperature at 1.5 m was about 16.9 °C, relative humidity 85–87% and dew point about 14.6 °C. Wind at 10 m was nearly calm, with a mean speed of about 0.4 m s⁻¹ (1.5 km h⁻¹), gusts of about 1.3 m s⁻¹ and a S–SSE direction; it had dropped shortly before the survey, since until 17:00 it had blown at 1.7–2.2 m s⁻¹ with gusts of up to 4.7 m s⁻¹. Calm conditions reduce convective cooling of surfaces and the dispersion of the vapour plume, and wind at ground level in two sheltered squares would be even lower. The afternoon was aximizinged by progressive cooling, from 24 °C at 14:00, and a rapid rise in humidity, from 60% to 85% between 16:00 and 17:00. These conditions favour thermal contrast, with a water–air difference of about 50 °C, but they also make the vapour plume above the spouts more visible and probably left stone and paving still damp from the morning rain. There was no direct sunlight during the survey: sunshine duration was zero from 14:10 and global solar radiation remained at about 15–20 W m⁻². The last episode of appreciable radiation (up to about 600 W m⁻² around 13:50 and about 200 W m⁻² around 15:00) occurred two to three hours earlier, and after 16:00 radiation did not exceed 50 W m⁻². Solar loading on the fronts was therefore negligible, and the recorded gradients should be attributed to the thermal water. Residual heat from early-afternoon insolation on the most exposed walls cannot be ruled out and could partly explain why the reference masonry is warmer at Burga de Arriba (28.9 °C) than at Burga de Abaixo (24.4 °C); the orientation and degree of shelter of each front, which were not assessed, may also play a role.
Table 2. Acquisition conditions for each spring outlet.
Table 2. Acquisition conditions for each spring outlet.
Parameter Burga de Arriba Burga de Abaixo
Date and time (local) 12 April 2025, 17:23:43–17:24:24 CEST 12 April 2025, 17:25:23–17:27:53 CEST
Air temperature (°C) 16.9 (dew point ≈ 14.6) 16.9 (dew point ≈ 14.6)
Relative humidity (%) ≈ 85–87 ≈ 85–87
Wind speed (m/s) ≈ 0.4 (gusts ≈ 1.3), S–SSE; at 10 m ≈ 0.4 (gusts ≈ 1.3), S–SSE; at 10 m
Sky / solar exposure Overcast; no sunshine; global solar radiation ≈ 15–20 W m⁻². Rain in the morning only Overcast; no sunshine; global solar radiation ≈ 15–20 W m⁻². Rain in the morning only
Camera–object distance (m) ≈ 1.1 (frontal view; estimated from spout spacing, Eq. 8) ≈ 5.5 (frontal view; estimated from front width, Eq. 8)
Viewing angle (°) ≈0–45 (frontal and oblique views) ≈0–45 (frontal, oblique and close-up views)
Number of thermograms (acquired / analysed) 12 / 12 (ROI analysis on 172343) 55 / 55 (ROI analysis on 172608)
Data source for ambient values MeteoGalicia, Ourense-Estacións station (ID 10155), 10-min records

2.4. Radiometric Correction

Raw detector values (S) were converted to temperature not with the manufacturer’s software but with custom Python code that reads the FLIR records of the radiometric JPEG directly, whose structure is documented in ExifTool [25]. The standard FLIR radiometric model was applied, in the formulation implemented in the Thermimage package [26]. The signal corresponding to a blackbody at temperature T (K) is:
S T = R 1 R 2 e B / T − F − O
Atmospheric transmittance τ over distance d is computed from the water vapour content H, which depends on relative humidity RH and air temperature Ta (°C):
H = RH ⋅ e 1.5587 + 0.06939   T a − 2.7816 × 10 − 4   T a 2 + 6.8455 × 10 − 7   T a 3
τ = X   e − d 2   α 1 + β 1 H + 1 − X   e − d 2   α 2 + β 2 H
The signal emitted by the object is obtained by subtracting from the measured signal the contributions of the atmosphere, the optical window (transmittance τw, temperature Tw) and the reflected radiation (Trefl), weighted by emissivity ε:
S obj = S ε   τ 2   τ w − 1 − τ ε   τ   S T a − 1 − τ ε   τ 2   τ w   S T a − 1 − τ w ε   τ   τ w   S T w − 1 − ε ε   S T refl
T obj = B ln ​ R 1 R 2   S obj + O + F − 273.15
The constants R1, R2, B, F, O, X, α1, α2, β1 and β2 were read from the file itself and are identical in all 67 thermograms. The implementation was validated against the values displayed by the camera on a sample of 13 thermograms from Burga de Abaixo: the centre-spot reading (Sp1) was reproduced in all of them with differences ≤ 0.1 °C, and the colour-scale limits also matched within 0.1 °C in 12 of them; in the remaining one, the displayed scale did not correspond to the full range of the image.
All 67 files retain the default object parameters of the application: ε = 0.95; d = 1 m; Trefl = 22 °C; Ta = 20 °C; RH = 50%; τw = 0.80 at 25 °C. The reflected apparent temperature was not measured in the field. These values were taken as the reference case, and their effect on the results was quantified in the sensitivity analysis (Section 2.7) instead of replacing them with assumed values. Reference emissivities of 0.98 for water and 0.90–0.95 for granite were considered [10]. Replacing Ta and RH with the values recorded by MeteoGalicia (16.9 °C and 86%) and assuming Trefl = Ta, an approximation justified by the overcast sky and the absence of direct sunlight during the survey, raises all temperatures almost uniformly by 0.27–0.30 °C. The increments ΔT relative to the reference do not change, so the default parameters were kept as the reference case. The vapour rising from the spouts reduces the transmittance of the optical path and adds its own emission; its effect was bounded with an unfavourable atmospheric case (RH = 95%, d = 4 m, ε = 0.98).

2.5. Spatial Referencing and RGB–TIR Co-Registration

The embedded visible image (1440 × 1080 pixels) was registered to the thermal matrix by a similarity transformation (scale and translation, without rotation), since both sensors share the same mount and orientation. The factory alignment parameters stored in the file (Real2IR = 1.397; offsets of 25 and −6 pixels in landscape) are calibrated for a specific distance and, at the working distance, produced a noticeable vertical offset due to parallax. Scale and translation were therefore re-estimated by aximizing the cross-correlation between the gradient magnitudes (Sobel operator) of both images, previously smoothed with a Gaussian filter (σ = 2 px).
For the selected frontal views, a scale of 1.49 was obtained at both springs, with gradient correlation coefficients of 0.38 at Burga de Arriba and 0.22 at Burga de Abaixo. The isotherms match the spouts, basins and drain grate well (Figure 3). To quantify the residual error, six homologous points were identified visually in both images: the spout mouths (two at Arriba and three at Abaixo) and the centre of the drain grate at Abaixo. The root-mean-square error was 5.5 exported pixels at Burga de Arriba (about 9 mm on the object) and 8.4 pixels at Burga de Abaixo (about 7 cm), i.e., of the order of one native pixel of the thermal sensor (0.7 and 1.05 native pixels, respectively). The largest residual (14 pixels, at the right lateral spout of Abaixo) is attributed to the combination of the low native thermal resolution, which blurs the position of the mouth, and parallax between features at different depths, which a similarity transformation cannot correct. Since the GNSS position is the same for the whole session, the products are described as spatially referenced thermograms rather than orthomosaics.

2.6. Thermal Anomaly Analysis

In each selected frontal view, rectangular regions of interest (ROIs) were defined on the thermal matrix, guided by the registered visible image (Figure 4 and Figure 5), following the same logic at both springs. W regions correspond to water (jets, basins, basin overflow), M regions to masonry, including a reference far from the water (M2), and P regions to paving, distinguishing paving away from the thermal water from paving receiving runoff or drainage. Nine ROIs were defined at Burga de Arriba: the jets of the left (W1) and right (W2) spouts, the water surface in the right (W3) and left (W4) basins, the masonry between the spouts (M1), the upper masonry above the spouts (M3), the reference (M2), paving away from the thermal water (P1) and paving wetted by runoff (P2). Eight were defined at Burga de Abaixo: the jet on the central column (W1), the basin overflow (W2), the right (W3) and left (W4) lateral jets, the niche masonry (M1), a pilaster as reference (M2), paving away from the thermal water (P1) and the drain grate (P2). For each ROI, the mean, maximum, minimum, standard deviation and increment relative to the reference of its own spring were computed:
Δ T ROI = T ¯ ROI − μ ref
where μref is the mean temperature of the reference region M2. A pixel was considered anomalous when its ΔT exceeded twice the standard deviation of that same region (σref) i.e., when ΔT > 2σref. Anomalies were further classified into three intensity levels (ΔT > 5, > 15 and > 25 °C) to distinguish heating of the masonry from the water itself. Since the masonry references differ between springs owing to orientation and exposure, the comparison between springs also relies on paving away from the thermal water (P1), whose temperature turned out to be identical at both.
Two line profiles were drawn at each spring: a vertical one (A), along the main jet from the wall to the paving, and a horizontal one (B), crossing the jet and the masonry on either side. The area of each class is expressed as a fraction of the frame; converting it to square metres requires the acquisition distance:
p = d ⋅ IFOV ; A = N k 2   p 2
where p is the native pixel size on the object, N the number of pixels of the exported matrix and k = 8 the interpolation factor (640/80).
Since the distance stored in the files is the default value (1 m) and was not measured in the field, the distance of each frontal view was estimated from a known dimension of the monument. If s is the actual separation between two features lying in a plane approximately normal to the optical axis and Δx their separation in the thermal matrix (in pixels), then:
d = s   f px Δ x ; f px = W 2 tan HFOV 2
where W = 640 pixels is the width of the matrix and HFOV the horizontal field of view. At Burga de Arriba, the spacing between the two spouts (s = 0.40 m, measured in situ and checked against IGN mapping) corresponds to Δx = 256 pixels measured between the thermal maxima of the mouths, giving d ≈ 1.07 m (1.05–1.10 m for an HFOV of 50 ± 1°). At that distance, the frame covers about 1.00 × 0.75 m in the plane of the spouts, the exported pixel measures about 1.6 mm and the native pixel about 1.25 cm. At Burga de Abaixo, the reference was the total width of the monumental front measured in plan at the cornice: s = 6.85 m on the orthophoto, a value corroborated in the Spanish Cadastre viewer. Since the front does not fit entirely within the thermal frame of the frontal view, its ends were located in the visible image (1287 pixels) and transformed to the thermal scale with the registration parameters (Δx ≈ 852 pixels). This gives d ≈ 5.5 m (5.4–5.6 m for an assumed HFOV tolerance of ±1°; 5.4–5.6 m for a registration scale of 1.49 ± 0.03). At that distance, the thermal frame covers about 5.1 × 3.9 m, the exported pixel measures about 8 mm and the native pixel about 6.4 cm, five times more than in the frontal view of Burga de Arriba.

2.7. Uncertainty and Sensitivity Analysis

The mean temperatures of each ROI were recomputed from the raw values by varying one parameter at a time. Emissivity was varied between 0.90 and 0.98 in steps of 0.02, with Trefl = 22 °C, and reflected temperature between 17 and 27 °C (±5 °C) in steps of 1 °C, with ε = 0.95. In addition, the unfavourable atmospheric case described in Section 2.4 was evaluated.
Two non-radiometric sources of uncertainty were also analysed. The first is repeatability: the range of the maximum was computed within each burst of consecutive frames, defined as images ≤3 s apart with the same orientation (18 bursts, 63 thermograms). Since images were taken hand-held, this range includes both sensor noise and small framing variations between frames and is therefore a conservative estimate of field repeatability. The second is spatial resolution: maxima of the same feature were compared between overview images and close-ups. As an indirect validation, the maximum radiometric water temperature was compared with published spring temperatures, without treating them as simultaneous measurements.

2.8. Use of Generative AI

During the preparation of this work, the author used ChatGPT (OpenAI) to compile preliminary background information on the study site and on infrared thermography methods, and Claude (Anthropic) to assist in developing the Python scripts for radiometric processing and RGB–TIR co-registration, in structuring and drafting the manuscript, in searching for and checking references, and in translating the text into English. All content was subsequently verified against primary sources and the original data, reviewed and edited by the author, who takes full responsibility for the content of this publication.

3. Results

3.1. Thermal Field of Burga de Arriba

Heat at Burga de Arriba is concentrated in its two spouts and in the basins that collect the water at ground level (Figure 4; Table 3). In the frontal view, the jet of the left spout (W1) has a mean of 51.2 °C and a maximum of 57.0 °C. The right jet (W2), much thinner in the image, reaches only 41.7 and 50.6 °C. The water surface of the right basin (W3) is the hottest surface in the frame (mean 55.3 °C; maximum 60.7 °C), followed by the left basin (W4: 48.1 and 57.6 °C).
The masonry between the spouts (M1) is at 32.8 °C, 3.9 °C above the reference (M2: 28.9 ± 1.6 °C). More striking is the upper band of the fountain body (M3), at 35.5 °C (+6.6 °C), warmer than the masonry between the spouts despite being further from visible water. Paving wetted by runoff (P2: 32.4 °C) is 5.5 °C warmer than paving away from the thermal water (P1: 26.9 °C).
Across the 12 thermograms, the maximum ranges from 59.6 to 61.9 °C depending on the view type (Table 4), the highest value corresponding to the right basin in the frontal series. None of the Burga de Arriba images is a close-up of a spout, so these maxima should be read as overview values.

3.2. Thermal Field of Burga de Abaixo

The thermal field of Burga de Abaixo is dominated by the three water outlets and by the film overflowing the central basin (Figure 5; Table 3). In the frontal view, the jet on the central column (W1) has a mean of 52.5 °C and a maximum of 55.9 °C. The right lateral spout (W3) reaches a mean of 50.3 °C and a maximum of 55.5 °C, and the left one (W4) 43.2 and 49.1 °C. The water overflowing the front of the basin (W2) remains at a mean of 42.3 °C, with greater dispersion (σ = 4.0 °C), consistent with a film of variable thickness over the ashlar.
The masonry responds very differently depending on its proximity to the water. The niche masonry next to the central outlet (M1) is at 31.2 °C, 6.8 °C above the reference pilaster (M2: 24.4 ± 0.8 °C). Paving away from the thermal water (P1) is at 26.9 °C, the same value as at Burga de Arriba, whereas the drain grate in front of the basin (P2) reaches 42.7 °C, 15.8 °C more than the surrounding paving.
Considering all 55 thermograms, the maximum clearly depends on the view type (Table 4). It ranges from 55.9–57.4 °C in frontal overviews to 62.0–63.1 °C in details of the crown of the central outlet, 62.8–64.0 °C in close-ups of the right spout and 68.5 °C in those of the left spout, where the maximum corresponds to the water surface of its basin. The difference of about 7 °C between the means of the two lateral spouts in the frontal view therefore does not reflect a real difference in water temperature. At the distance of this view (about 5.5 m), the native pixel measures about 6.4 cm on the object, twice the width of a 2–3 cm jet such as those measured at Burga de Arriba. Each jet thus fills less than half of a native pixel, and its temperature is averaged with that of the colder surrounding masonry (Section 3.6).

3.3. Statistical Characterisation by Material and Element

Table 3. Temperature statistics by region of interest (°C).
Table 3. Temperature statistics by region of interest (°C).
Outlet ROI/element Mean Max Min SD ΔT vs. background
Arriba W1 Left spout jet 51.2 57.0 43.2 3.4 +22.3
Arriba W2 Right spout jet 41.7 50.6 34.0 4.5 +12.9
Arriba W3 Right basin pool 55.3 60.7 40.9 4.2 +26.4
Arriba W4 Left basin pool 48.1 57.6 34.0 5.0 +19.2
Arriba M1 Masonry between spouts 32.8 37.2 30.8 1.5 +3.9
Arriba M3 Upper masonry above spouts 35.5 37.9 29.7 1.7 +6.6
Arriba M2 Reference masonry 28.9 32.4 26.0 1.6 +0.0
Arriba P1 Paving (away from thermal water) 26.9 29.4 25.8 0.7 -2.0
Arriba P2 Paving (wet, runoff) 32.4 33.3 30.5 0.6 +3.5
Abaixo W1 Central jet (water on column) 52.5 55.9 40.0 2.4 +28.1
Abaixo W2 Basin overflow (wet ashlar) 42.3 49.1 37.3 4.0 +17.9
Abaixo W3 Right lateral spout jet 50.3 55.5 40.4 3.8 +25.9
Abaixo W4 Left lateral spout jet 43.2 49.1 38.0 3.1 +18.8
Abaixo M1 Niche masonry near outlet 31.2 36.0 28.2 1.5 +6.8
Abaixo M2 Reference masonry (pilaster) 24.4 26.1 22.7 0.8 +0.0
Abaixo P1 Paving (away from thermal water) 26.9 29.0 25.2 0.8 +2.5
Abaixo P2 Drain grate 42.7 46.4 36.4 1.4 +18.3
Table 4. Maximum radiometric temperature (°C) by view type for the 67 thermograms (default object parameters).
Table 4. Maximum radiometric temperature (°C) by view type for the 67 thermograms (default object parameters).
Outlet View type n Min of max Max of max Mean of max Max P99
Arriba Frontal general 5 60.7 61.9 61.2 54.4
Arriba Oblique general 5 59.6 60.5 59.9 51.8
Arriba Oblique close-up 2 61.1 61.4 61.3 50.3
Abaixo Frontal general 5 55.9 57.4 56.3 52.8
Abaixo Central fountain, vertical (general) 5 56.2 58.0 57.2 54.4
Abaixo Central fountain, vertical (closer) 7 60.1 60.8 60.5 57.1
Abaixo Central fountain, medium/oblique 10 58.3 61.2 59.9 59.2
Abaixo Central outlet crown, detail 12 62.0 63.1 62.6 62.2
Abaixo Right lateral spout, close-up 5 62.8 64.0 63.4 57.7
Abaixo Left lateral spout, close-up 11 58.3 68.5 65.8 67.4

3.4. Thermal Profiles Across the Water–Masonry Interface

Burga de Arriba. The vertical profile A, drawn along the left spout (Figure 6a), rises from 32.9 °C on the wall above the spout to 53–54 °C at the mouth. Unlike at Burga de Abaixo, it does not cool along the fall: it peaks (56.9 °C) halfway down the jet and remains at 50.5–52.6 °C down to the basin. At the basin rim it drops sharply to 37.6 °C and on the paving it stays at 29–31 °C. The horizontal profile B records 56.3 °C on the left jet and only 39.6 °C on the right one, which in this view occupies less than two native pixels. Between them, the masonry remains at 31–36 °C.
Burga de Abaixo. The vertical profile A (Figure 6b) rises from 27.8 °C on the wall above the spout to 55.7 °C at the outlet of the jet. It decreases steadily along the fall (52.8 °C halfway; 43.1 °C on reaching the basin) and shows a second peak of 48.2 °C at the basin rim, where the water overflows. It drops to 37.6 °C at the plinth, rises again to 43.5 °C over the drain grate and ends at 31.1 °C on the paving. The horizontal profile B reaches 54.1 °C on the jet and falls sharply on either side, but the masonry stays above 30 °C over 9–16 native pixels on each side; the halo is wider towards the basin.

3.5. Thermal Anomaly Mapping

Burga de Arriba. With μref = 28.9 °C and σref = 1.6 °C, the anomaly threshold is 32.1 °C. It is exceeded by 44.1% of the frame; 28.2% exceeds ΔT > 5 °C, 3.7% ΔT > 15 °C and 0.9% ΔT > 25 °C, the latter restricted to the jets and basins (Figure 7a). Outside the water, two anomalies stand out. The first is the upper band of the fountain body (M3, +6.6 °C), whose position, above the spouts and away from wet surfaces, admits several explanations that these data cannot discriminate: heat conduction from the internal path of the water to the spouts, heating by the moist air and vapour rising from the basins and trapped under the cornice, or residual heat from early-afternoon insolation. The second is the runoff patch on the paving in front of the basins (P2). With the estimated scale (Section 2.6), the area exceeding the threshold amounts to about 0.33 m² in the plane of the spouts; that with ΔT > 5 °C to 0.21 m²; with ΔT > 15 °C to 0.028 m²; and with ΔT > 25 °C to 0.007 m². These figures are approximate, because the frame combines the vertical wall with foreshortened paving. μref
Burga de Abaixo. With μref = 24.4 °C and σref = 0.82 °C, the threshold is 26.0 °C. It is exceeded by 67.3% of the frame, indicating that the whole front, and not only the spouts, is thermally influenced by the water (Figure 7b). 43.1% exceeds ΔT > 5 °C, 10.4% ΔT > 15 °C and 1.8% ΔT > 25 °C. Two anomalies not corresponding to visible water stand out: the halo of heated masonry in the niche around the central outlet (M1, +6.8 °C) and the drain grate in the paving (P2, +18.3 °C relative to the reference), most probably caused by thermal water flowing through the drainage network. With the estimated scale (Section 2.6), the area exceeding the threshold amounts to about 13.4 m²; that with ΔT > 5 °C to 8.6 m²; with ΔT > 15 °C to 2.1 m²; and with ΔT > 25 °C to 0.36 m². These values are approximate, because a significant part of the frame is foreshortened paving, whose actual area is larger than the projected one.

3.6. Sensitivity to Emissivity and Reflected Temperature

Increasing emissivity from 0.90 to 0.98 lowers the mean temperature of the water ROIs by 1.6–2.5 °C at both springs and that of masonry and paving ROIs by 0.2–1.1 °C (Figure 8a; Table 5). Varying the reflected temperature by ±5 °C changes all ROIs by ≤0.5 °C (Figure 8b), and the unfavourable atmospheric case by ≤0.5 °C. Repeatability between consecutive frames is of the same order: across the 18 bursts, the median range of the maximum is 0.4 °C, with a maximum of 1.2 °C.
Spatial resolution, by contrast, has an effect one order of magnitude larger (Table 4; Figure 9). At Burga de Abaixo, the maximum of the right lateral spout rises from 55.5 °C in the frontal view to 64.0 °C in the close-up (+8.5 °C), and that of the left spout from 49.1 to 68.5 °C (+19.4 °C). The crown of the central outlet rises from 55.9 °C to 62.0–63.1 °C (+6.1 to +7.2 °C). These maxima can be compared with the published spring temperatures of each fountain: 64.8–65.3 °C at Burga de Arriba and 66.3–67 °C at Burga de Abaixo according to recent determinations [14,17,18,19], with 66.5 and 67 °C, respectively, in the description by Taboada Leal (1877) [19,22] and 67 °C on the information plaque installed by the City Council next to Burga de Abaixo in 1991. At Burga de Abaixo, the close-up maximum (68.5 °C with ε = 0.95) drops to 67.3 °C when the emissivity of water (ε = 0.98) is applied and to 67.4 °C with the conditions recorded in the field (Ta = 16.9 °C; RH = 86%; Trefl = Ta), i.e., only 0.4–1.1 °C above the published spring values and well within the nominal accuracy of the device (±3 °C). This agreement indicates that, when the feature is recorded with enough pixels, the procedure retrieves the water temperature with an error of the order of the nominal accuracy of the device. At Burga de Arriba, the maximum (61.9 °C; 60.8 °C with ε = 0.98) lies 3.8–4.5 °C below recent values for its spring (61.0 °C with field conditions). Although the frontal view was taken at only 1.1 m, the jets have an apparent width of about 2–3 cm in it, i.e., barely 2 native pixels of 1.25 cm, and the maximum was recorded on the more extensive water surface of the basin. This difference is therefore compatible with the same resolution effect, attenuated relative to the overviews of Abaixo.

4. Discussion

4.1. Comparison Between the Two Spring Outlets

For the same view type, both springs show thermal fields of comparable intensity: overview maxima are 59.6–61.9 °C at Burga de Arriba and 55.9–61.2 °C at Burga de Abaixo. Their organisation, however, differs. At Burga de Arriba, the water leaves through two low spouts and collects in ground-level basins, so heat is concentrated in the lower plane and spreads over the paving through runoff (P2). At Burga de Abaixo, the water falls down a column and overflows a stepped basin, which distributes heat vertically and warms a much larger area of masonry (67% of the frame exceeds the threshold, versus 44%).
The jet at Burga de Arriba does not cool along its fall, whereas the column jet at Abaixo loses about 12 °C between the outlet and the basin. One explanation is that at Abaixo the water runs down as a film over the stone and gives up heat to the masonry, while at Arriba it falls freely. The anomalies not associated with visible water, the upper band at Arriba and the drain grate at Abaixo, show that thermography also detects hidden water paths. Absolute maxima (61.9 versus 68.5 °C) should not be compared directly, because no close-ups were taken at Burga de Arriba. Even so, their order matches that of the published spring temperatures (64.8–65.3 °C at Arriba and 66.3–67 °C at Abaixo): water emerges hotter at the lower spring (115 versus 119 m a.s.l.), which also has a much higher discharge (between about 1 and 3.05 L s⁻¹, according to different passages of the same work, versus 0.23 L s⁻¹, i.e., 4 to 13 times more) [14,18]. A higher discharge reduces the residence time of the water in the conduit [16] and, with it, its cooling before emergence, which is consistent with the temperature difference and with the greater heating of the masonry observed at Burga de Abaixo. Thermography therefore distinguishes the two springs when equivalent views are compared; quantifying the difference precisely would require repeating at Arriba the close-ups taken at Abaixo.

4.2. Comparison with Previous Studies

Airborne and UAS thermal remote sensing studies of hydrothermal systems stress that pixel size constrains both the detection of springs and the quantities derived from them [1,2]. This study quantifies that effect at ground scale with a sensor of very low native resolution: when the jet occupies less than one native pixel, the maximum is underestimated by 6–19 °C, whereas with 1.25 cm pixels the difference from the spring temperature drops to about 4 °C. The result is consistent with the general principle that radiometric measurement is only reliable when the target fills several instantaneous fields of view [8,10], but it provides specific values for a scenario that is common in practice and poorly documented.
In the heritage literature, thermography is mainly used to locate moisture and infiltration from contrasts of a few degrees [3,4,5]. At As Burgas the water itself is the heat source, and contrasts exceed 40 °C. Even so, the method reproduces the logic of those studies: the halo of heated masonry (+3.9 to +6.8 °C) and the anomalies without visible water, the drain grate at Abaixo and the upper band at Arriba, reveal hidden water paths just as thermography reveals infiltration in masonry. The validation against spring temperatures, with differences of 0.4–1.1 °C when the feature is recorded with enough pixels, also shows that a low-cost module can provide quantitative data if acquisition geometry is controlled.

4.3. Radiometric Challenges in Built Hydrothermal Environments

The main methodological result is that, with a low-resolution device, the dominant uncertainty is geometric rather than radiometric. A variation in ε of 0.08, which covers the plausible range for water and wet stone, shifts water temperatures by 1.6–2.5 °C, and reflected temperature, atmosphere and repeatability do not exceed 0.5 °C for typical values. By contrast, in the frontal view of Abaixo, taken at about 5.5 m, the native pixel measures 6.4 cm: a 2–3 cm jet fills less than half of the pixel, which integrates water and colder masonry, and maxima are underestimated by 6–19 °C. At Arriba, taken at 1.1 m with 1.25 cm pixels, the underestimation relative to the spring temperature is only about 4 °C. Three recommendations follow: (i) set the distance so that each feature of interest occupies at least 3 × 3 native pixels (jets have an apparent width of about 2–3 cm in the frontal view of Arriba); (ii) always complement each overview with close-ups of all outlets; (iii) to estimate water temperature, measure on the basin water surfaces, which are more extensive than the jets. The acquisition conditions add two nuances. The 85–87% humidity and cool air make the vapour plume above the spouts denser, although its measured radiometric effect is small (≤0.5 °C). In addition, the morning rain probably left stone and paving damp, which raises their emissivity but also cools them by evaporation and may lower the reference temperatures (in the visible images, much of the paving still appears wet).

4.4. Limitations

This study has several limitations. Object parameters were not adjusted in the field (default application values), and neither reflected temperature nor air temperature was measured in situ. The native resolution of the sensor is 80 × 60 pixels. The survey consisted of a single session of about four minutes on one date and at one time of day, and all images share the same GNSS position. Images were taken hand-held, without a tripod, with uncontrolled framing and distance, and no close-ups were taken at Burga de Arriba. No simultaneous contact probe was used to validate water temperature. Only two of the spring outlets of the ensemble were studied (the Fervedoiro and the pool of Burga do Medio were not). Thermography observes surface temperatures and does not directly inform about discharge or the subsurface. Finally, anomalous areas were computed on the frontal plane and are approximate in the foreshortened paving areas.

4.5. Proposed Monitoring Protocol

Based on the results, a six-step monitoring protocol is proposed (Figure 10). (1) Planning: seasonal campaigns at several time windows (dawn, shade and night, to minimise solar loading), fixed and marked acquisition stations, permanent ROIs and access permits. (2) Geometric design: set the distance so that each feature of interest occupies at least 3 × 3 native pixels and always combine an overview with close-ups of all outlets, with scale references in the frame. (3) Acquisition: record distance and angle, measure reflected temperature with a diffuse reflector, note ambient conditions and measure the water with a simultaneous contact probe; where possible, add time-lapse recording. (4) Radiometric processing: convert raw values with field parameters and per-material emissivities, and accompany each result with its sensitivity analysis. (5) Co-registration: align RGB and TIR with control points and, in future campaigns, merge with 3D photogrammetry and, if authorised, with UAS. (6) Analysis: ROI statistics, profiles, anomaly classes in square metres, comparison with the probe and change detection between campaigns. Extending the protocol to the Fervedoiro and the pool would complete the characterisation of the ensemble.

5. Conclusions

This study has applied ground-based radiometric infrared thermography to the two monumental fountains of As Burgas by processing the raw values of 67 thermograms acquired with a low-cost camera. The procedure, which combines a custom radiometric model, RGB–TIR co-registration, regions of interest, profiles and anomaly classification, made it possible to map and quantify the thermal field of two spring outlets of different architecture without contact with a protected property.
Maximum radiometric water temperatures were 61.9 °C at Burga de Arriba and 68.5 °C at Burga de Abaixo. With the emissivity of water and the meteorological conditions of the survey, the Abaixo value becomes 67.4 °C, within 0.4–1.1 °C of the published spring temperatures. The adjacent masonry is heated by 3.9–6.8 °C above the reference masonry, and thermography reveals water paths that are not visible: the drainage network at Abaixo and, at Arriba, a warm band of masonry above the spouts whose origin remains to be confirmed.
The main methodological contribution is the hierarchy of uncertainties. Radiometric parameterisation (emissivity, reflected temperature, atmosphere) and repeatability contribute 0.5–2.5 °C, whereas spatial resolution causes maximum water temperatures to be underestimated by 6–19 °C when jets occupy less than one native pixel. In built hydrothermal environments, acquisition distance matters more than emissivity.
These results support the use of thermography as a preventive conservation tool for hydrothermal heritage: detecting leaks and hidden water paths, monitoring heating of the masonry and tracking the thermal stability of the springs. Future work should apply the proposed protocol in seasonal campaigns with simultaneous contact measurements and extend it to the remaining spring outlets of the ensemble.

Author Contributions

The author was solely responsible for the conceptualization, methodology, data acquisition, software, formal analysis, writing and visualization of this study, and has read and agreed to the published version of the manuscript.

Funding

This research received no external funding. This article forms part of the research project “Spanish Urban Narrative” (LaNUbE), funded under the 12th Research Call of Camilo José Cela University.

Data Availability Statement

The thermographic data presented in this study are available on request from the corresponding author.

Conflicts of Interest

The author declares no conflicts of interest.

Abbreviations

The following abbreviations are used in this manuscript:
BIC Bien de Interés Cultural (Spanish heritage designation)
GNSS Global Navigation Satellite System
HFOV Horizontal field of view
IFOV Instantaneous field of view
NETD Noise-equivalent temperature difference
ROI Region of interest
RH Relative humidity
TIR Thermal infrared
UAS Unmanned aircraft system

References

  1. Haselwimmer, C.; Prakash, A.; Holdmann, G. Quantifying the heat flux and outflow rate of hot springs using airborne thermal imagery: Case study from Pilgrim Hot Springs, Alaska. Remote Sens. Environ. 2013, 136, 37–46. [CrossRef]
  2. Harvey, M.C.; Rowland, J.V.; Luketina, K.M. Drone with thermal infrared camera provides high resolution georeferenced imagery of the Waikite geothermal area, New Zealand. J. Volcanol. Geotherm. Res. 2016, 325, 61–69. [CrossRef]
  3. Avdelidis, N.P.; Moropoulou, A. Applications of infrared thermography for the investigation of historic structures. J. Cult. Herit. 2004, 5, 119–127. [CrossRef]
  4. Kylili, A.; Fokaides, P.A.; Christou, P.; Kalogirou, S.A. Infrared thermography (IRT) applications for building diagnostics: A review. Appl. Energy 2014, 134, 531–549. [CrossRef]
  5. Barreira, E.; Almeida, R.M.S.F.; Delgado, J.M.P.Q. Infrared thermography for assessing moisture related phenomena in building components. Constr. Build. Mater. 2016, 110, 251–269. [CrossRef]
  6. Rodríguez Elizalde, R. Assessment of Architectural Heritage and Historic Structures Through Aerial Thermography. Rev. Gest. Soc. Ambient. 2024, 18, e08761. [CrossRef]
  7. Rodríguez Elizalde, R. Thermography Applied to Old Masonry Constructions. In Modern Masonry Construction—The Fusion of Tradition, Technology, and Sustainability; Yilmaz, S., Ed.; IntechOpen: London, UK, 2025; ISBN 978-1-83634-666-1. [CrossRef]
  8. Usamentiaga, R.; Venegas, P.; Guerediaga, J.; Vega, L.; Molleda, J.; Bulnes, F.G. Infrared thermography for temperature measurement and non-destructive testing. Sensors 2014, 14, 12305–12348. [CrossRef]
  9. Minkina, W.; Dudzik, S. Infrared Thermography: Errors and Uncertainties; John Wiley & Sons: Chichester, UK, 2009.
  10. Vollmer, M.; Möllmann, K.-P. Infrared Thermal Imaging: Fundamentals, Research and Applications, 2nd ed.; Wiley-VCH: Weinheim, Germany, 2018.
  11. ASTM E1933-14(2018); Standard Practice for Measuring and Compensating for Emissivity Using Infrared Imaging Radiometers. ASTM International: West Conshohocken, PA, USA, 2018. Available online: https://store.astm.org/e1933-14r18.html (accessed on 4 October 2026).
  12. Decreto 17/2007, de 8 de febrero, por el que se declara bien de interés cultural, con la categoría de sitio histórico, el conjunto de fuentes termales de As Burgas y su entorno delimitado, en el Ayuntamiento de Ourense. Boletín Oficial del Estado, no. 89, 13 April 2007. Available online: https://www.boe.es/diario_boe/txt.php?id=BOE-A-2007-7856 (accessed on 4 October 2026).
  13. Braña Rey, F. Patrimonio, usos sociales y agua termal en Ourense. Rev. PH 2026, 118, 162–183. [CrossRef]
  14. Araujo Nespereira, P.A.; Cid Fernández, J.A.; Delgado Outeiriño, I.; Güezmes Barriuso, A.L. Inventario y caracterización del yacimiento termal de Ourense ciudad (Galicia, España); Technical Report; Universidade de Vigo–Xeoaquis: Ourense, Spain, n.d. Available online: https://www.xeoaquis.com/admin/docs/070501 YACIMIENTO GEOTERMICO OURENSE-CIUDAD.pdf (accessed on 4 October 2026).
  15. López, D.L.; Araujo, P.A.; Delgado Outeiriño, I.; Cid, J.A.; Astray, G. Geochemical signatures of the groundwaters from Ourense thermal springs, Galicia, Spain. Sustain. Water Resour. Manag. 2019, 5, 103–116. [CrossRef]
  16. Delgado-Outeiriño, I.; Araujo-Nespereira, P.; Cid-Fernández, J.A.; Mejuto, J.C.; Martínez-Carballo, E.; Simal-Gándara, J. Behaviour of thermal waters through granite rocks based on residence time and inorganic pattern. J. Hydrol. 2009, 373, 329–336. [CrossRef]
  17. Cid Fernández, J.A. Estudio de la Potencialidad del Yacimiento Geotérmico Ourense-Ciudad. Ph.D. Thesis, Universidade de Vigo, Ourense, Spain, 2024. Available online: https://hdl.handle.net/11093/6268 (accessed on 4 October 2026).
  18. Fernández Marcos, M.D. Caracterización de Productos Derivados de las Aguas Termales del Balneario de Laias para Usos Termoterapéuticos. Ph.D. Thesis, Universidade de Vigo, Ourense, Spain, 2024. Available online: https://www.investigo.biblioteca.uvigo.es/xmlui/handle/11093/7787 (accessed on 4 October 2026).
  19. Souto Figueroa, M.G. Las Aguas Misteriosas en la Galicia Interior: Ourense; Real Academia Europea de Doctores: Barcelona, Spain, 2025. Available online: https://raed.academy/wp-content/uploads/2025/02/Las-aguas-misteriosas-en-la-Galicia-interior-Ourense-por-Maria-Generosa-Souto-Figueroa.pdf (accessed on 4 October 2026).
  20. Rodríguez González, M. Las augas termales en Ourense. Fuente de desarrollo urbanístico y renovación urbana. Rev. Galega Adm. Pública 2013, 45, 461–514.
  21. Eguileta Franco, J.M. Ourense, sucesión de ciudades estratificadas por el tiempo: El entramado romano. Porta Aira 2008, 12, 51–106.
  22. Taboada Leal, N. Hidrología Médica de Galicia, o sea, Noticia de las Aguas Minero-Medicinales de las Cuatro Provincias de este Antiguo Reino; Establecimiento Tipográfico de Pedro Núñez: Madrid, Spain, 1877.
  23. FLIR Systems. FLIR ONE Gen 3, iOS: Technical Datasheet; Publ. No. 435-0004-03; FLIR Systems, Inc.: Wilsonville, OR, USA, 2021.
  24. MeteoGalicia. Rede de Estacións Meteorolóxicas: Ourense-Estacións (ID 10155), Ten-Minute Records for 12 April 2025. Xunta de Galicia. Available online: https://www.meteogalicia.gal (accessed on 4 October 2026).
  25. Harvey, P. ExifTool: Read, Write and Edit Meta Information, FLIR Tags. Available online: https://exiftool.org/TagNames/FLIR.html (accessed on 4 October 2026).
  26. Tattersall, G.J. Thermimage: Thermal Image Analysis, R Package Version 4.1.3; 2021. Available online: https://CRAN.R-project.org/package=Thermimage (accessed on 4 October 2026). [CrossRef]
Figure 3. Example of RGB–TIR co-registration at Burga de Abaixo: (a) visible image with the footprint of the thermal frame; (b) radiometric thermogram; (c) fused product with the 30, 40 and 50 °C isotherms.
Figure 3. Example of RGB–TIR co-registration at Burga de Abaixo: (a) visible image with the footprint of the thermal frame; (b) radiometric thermogram; (c) fused product with the 30, 40 and 50 °C isotherms.
Preprints 239720 g003
Figure 4. Burga de Arriba: (a) visible image; (b) corrected thermogram with regions of interest (ROIs).
Figure 4. Burga de Arriba: (a) visible image; (b) corrected thermogram with regions of interest (ROIs).
Preprints 239720 g004
Figure 5. Burga de Abaixo: (a) visible image; (b) corrected thermogram with regions of interest (ROIs).
Figure 5. Burga de Abaixo: (a) visible image; (b) corrected thermogram with regions of interest (ROIs).
Preprints 239720 g005
Figure 6. Temperature profiles across the water–masonry interface: (a) Burga de Arriba; (b) Burga de Abaixo.
Figure 6. Temperature profiles across the water–masonry interface: (a) Burga de Arriba; (b) Burga de Abaixo.
Preprints 239720 g006
Figure 7. Thermal anomaly maps overlaid on the visible images: (a) Burga de Arriba; (b) Burga de Abaixo.
Figure 7. Thermal anomaly maps overlaid on the visible images: (a) Burga de Arriba; (b) Burga de Abaixo.
Preprints 239720 g007
Figure 8. Sensitivity of retrieved ROI mean temperatures to (a) emissivity and (b) reflected apparent temperature, for Burga de Arriba (top) and Burga de Abaixo (bottom).
Figure 8. Sensitivity of retrieved ROI mean temperatures to (a) emissivity and (b) reflected apparent temperature, for Burga de Arriba (top) and Burga de Abaixo (bottom).
Preprints 239720 g008
Figure 9. Effect of acquisition distance on retrieved maximum water temperatures at Burga de Abaixo: (a) frontal overview; (b) close-up of the right lateral spout; (c) close-up of the left lateral spout (same colour scale, 22–69 °C).
Figure 9. Effect of acquisition distance on retrieved maximum water temperatures at Burga de Abaixo: (a) frontal overview; (b) close-up of the right lateral spout; (c) close-up of the left lateral spout (same colour scale, 22–69 °C).
Preprints 239720 g009
Figure 10. Proposed workflow for the thermographic monitoring of built hydrothermal heritage.
Figure 10. Proposed workflow for the thermographic monitoring of built hydrothermal heritage.
Preprints 239720 g010
Table 1. Technical specifications of the thermal imaging camera.
Table 1. Technical specifications of the thermal imaging camera.
Parameter Value
Camera model FLIR ONE Gen 3 for iOS, FLIR Systems (smartphone module)
Detector type and resolution (pixels) Uncooled microbolometer, 17 µm pitch; 80 × 60 native; radiometric matrix exported at 640 × 480 (interpolated)
Spectral range (µm) 8–14
Thermal sensitivity (NETD, mK) 150
Accuracy (°C or %) ±3 °C or 5% of the ambient–scene difference
Field of view / IFOV (mrad) 50° × 38°; IFOV 12 mrad
Temperature range (°C) −20 to 120
Integrated visible camera / GPS Visible camera 1440 × 1080 px; GNSS position from paired smartphone (EXIF)
Output format (radiometric JPEG, SEQ, etc.) Radiometric JPEG (FLIR FFF records in APP1 segments)
Table 5. Sensitivity of ROI mean temperatures (°C) to emissivity (ε) and reflected apparent temperature (Trefl). Δ = absolute change over the tested range (ε from 0.90 to 0.98 in steps of 0.02; Trefl from 17 to 27 °C in steps of 1 °C).
Table 5. Sensitivity of ROI mean temperatures (°C) to emissivity (ε) and reflected apparent temperature (Trefl). Δ = absolute change over the tested range (ε from 0.90 to 0.98 in steps of 0.02; Trefl from 17 to 27 °C in steps of 1 °C).
Outlet – ROI T (ε = 0.90) T (ε = 0.98) Δε T (Trefl = 17) T (Trefl = 27) ΔTrefl
Arriba – W1 Left spout jet 52.6 50.4 2.2 51.4 51.0 0.4
Arriba – W2 Right spout jet 42.7 41.2 1.6 42.0 41.5 0.4
Arriba – W3 Right basin pool 56.9 54.4 2.5 55.5 55.1 0.4
Arriba – W4 Left basin pool 49.4 47.4 2.0 48.3 47.9 0.4
Arriba – M1 Masonry between spouts 33.3 32.5 0.9 33.0 32.5 0.5
Arriba – M3 Upper masonry above spouts 36.2 35.1 1.1 35.7 35.3 0.5
Arriba – M2 Reference masonry 29.3 28.7 0.6 29.1 28.6 0.5
Arriba – P1 Paving (away from thermal water) 27.2 26.8 0.4 27.2 26.7 0.5
Arriba – P2 Paving (wet, runoff) 32.9 32.1 0.8 32.6 32.1 0.5
Abaixo – W1 Central jet (water on column) 54.0 51.7 2.3 52.7 52.3 0.4
Abaixo – W2 Basin overflow (wet ashlar) 43.3 41.7 1.6 42.5 42.1 0.4
Abaixo – W3 Right lateral spout jet 51.7 49.5 2.2 50.5 50.1 0.4
Abaixo – W4 Left lateral spout jet 44.3 42.6 1.7 43.4 43.0 0.4
Abaixo – M1 Niche masonry near outlet 31.7 31.0 0.8 31.5 31.0 0.5
Abaixo – M2 Reference masonry (pilaster) 24.5 24.3 0.2 24.6 24.1 0.5
Abaixo – P1 Paving (away from thermal water) 27.1 26.7 0.4 27.1 26.6 0.5
Abaixo – P2 Drain grate 43.7 42.1 1.6 42.9 42.5 0.4
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.
Copyright: This open access article is published under a Creative Commons CC BY 4.0 license, which permit the free download, distribution, and reuse, provided that the author and preprint are cited in any reuse.