Abstract
Checking maximum pile force can conceal relative uncertainty in drag because the head load dilutes its contribution. In 500 frozen synthetic cases, 29 of 105 joint total-force/settlement outer-envelope certificates at 10% are lost when drag increment replaces total force. We develop a procedure for deciding whether one constant compression coefficient meets both response tolerances. Ordered strain bounds are propagated through a finite-stiffness pile model with fixed monotone shaft and toe laws. Inverse-response intervals and a dimensionless tolerance-normalized index distinguish adequate simplification, insufficient information and incompatible response targets. A refined synthetic reference requires 16.124% minimum joint error; another case admits a 5.172% outer-envelope bound despite a 7.27 slope ratio. Nine published laboratory curves provide fit, shape and withheld-stress checks. AJOP reduces full-window and blocked RMSE relative to a constant logarithmic slope in all six Haihe specimens, while comparator and shape tests delimit that advantage. A Bangkok reconstruction tests transfer between monitored stages. The synthetic AJOP references are prescribed numerical benchmarks. The practical outcome is a shared admissible coefficient or a quantified reason to improve information or use a richer compression representation.
Keywords: 
;  ;  ;  ;  ;  ;  ;  

1. Introduction

Pile-supported buildings on compressible ground require assessment of axial force and serviceability throughout construction and subsequent ground movement. Relative soil–pile settlement mobilizes negative skin friction, while pile stiffness, toe restraint and foundation interaction determine the resulting movement. Capacity, structural force demand and settlement are distinct design questions in the unified pile-design framework and the National Cooperative Highway Research Program (NCHRP) downdrag guidance [1,2,3]. A smaller calculated drag force does not necessarily imply smaller settlement. In centrifuge tests, Leung et al. found that reducing the socket into dense sand could reduce dragload while increasing pile settlement [4]. This experimentally observed trade-off motivates evaluating a compression approximation against both outputs.
The building context extends beyond an isolated pile. Tsuchiya and Kishida already analysed differential building settlement caused by pile downdrag and identified the importance of the subgrade below the toes [5]. Piled-raft design uses piles partly to control overall and differential settlement [6]; comparisons of three monitored piled rafts examined settlement, differential settlement and load sharing together [7]. More recently, Zhu et al. monitored these interacting quantities for a 120 m residential piled-raft building equipped with deformation adjustors [8]. These studies establish multi-output foundation assessment as prior art. They also delimit the present single-pile analysis: a force–settlement criterion for one pile cannot establish the performance of an interacting building foundation.
Long-term observations show why the relevant loading stage and observation window must be explicit. A Shanghai database contains 195 building-settlement records, although some final settlements and stabilization times were obtained by extrapolation rather than observed completion [9]. Buttling et al. reported nine-year monitoring of a foundation comprising 399 bored piles supporting three 70-storey Bangkok towers, with load records from fifteen instrumented piles and settlement records at forty mat locations [10]. Mean mat settlement increased from approximately 90 mm near completion of construction to 140 mm at the end of monitoring. Missing site oedometer tests, free-field settlement and below-toe displacement prevent that case from validating a compression law. Earlier instrumented-pile observations likewise showed negative friction returning after a head-loading stage as regional settlement continued [11]. Thus a successful fit to one laboratory or construction stage is not sufficient evidence for long-term foundation prediction.
Shaft transfer and group interaction provide additional reasons to distinguish constitutive effects from changes elsewhere in the model. Model tests of individual, grouped and treated piles demonstrate sensitivity to arrangement and interface conditions [12]. Numerical group analyses explicitly include soil–pile slip [13], while recent single-pile and 3 × 3 group experiments show spacing- and position-dependent response [14]. The latter experiments concern model piles in sand, not a field clay foundation. Construction-stage monitoring of a 76.7 m bored pile also illustrates that head load and shaft resistance can be inferred through an assumed transfer model rather than measured directly [15]. Consequently, an apparent improvement obtained by changing compression, shaft transfer and toe stiffness together cannot be attributed uniquely to the compression law.
Movement-compatible downdrag calculations already incorporate substantial constitutive and hydraulic detail. Kim and Mission coupled finite-strain consolidation with nonlinear load transfer [16]; Wang and Brandenberg examined drainage and loading-history effects within a beam-on-nonlinear-foundation framework [17]. Russo et al. compared boundary- and finite-element approaches [18], and Jiang et al. linked consolidation to a modulus-dependent transfer formulation [19]. Wu et al. examined effective-stress and finite-element calculations while varying interface, drainage, time and loading assumptions [20]. Their Bangkok comparison reuses the same historical field programme considered here, so it is methodological precedent rather than an additional independent experiment.
Ashour and Abbas couple soil and pile movement with mobilized shaft and toe resistance [21], and Shu uses deformation-compatible load-transfer curves to estimate drilled-shaft drag and settlement [22]. Recent consolidation–pile models additionally address nonlinear creep and hydraulic boundary conditions [23,24]. A long/short-pile formulation for immersed loess evaluates axial force, shaft friction and movement using relative-displacement-dependent transfer [25]. These established capabilities motivate a different assessment question: within a specified forward model, can the same constant compression coefficient satisfy the selected tolerances for drag increment and settlement over a declared compression and transfer domain?
There is substantial prior evidence that the laboratory compression relationship itself can depend on structure and stress interval. Intrinsic reconstituted-clay behaviour provides a reference for natural fabric and bonding effects [26]; structured-clay frameworks describe changes associated with yielding and destructuration [27]. Liu and Carter represent virgin compression through an intrinsic contribution plus an additional structure-related void ratio that decreases with stress [28]. Alternative interpretations of natural-clay oedometer data address curvature, sample disturbance and the choice of plotting coordinates [29]. A disturbed-state model for high-water-content reconstituted clay permits the logarithmic compression index to decrease after yield [30]. A candidate family with an everywhere nondecreasing logarithmic slope therefore requires a shape test rather than an assumption of universal applicability.
Compression curvature must also be distinguished from other sources of nonlinearity. Nonlinear consolidation can retain a constant logarithmic compression index while permeability and geometry evolve, as in García-Ros and Alhama’s oedometer-based identification method [31]. Load–unload–reload models introduce explicit branch dependence [32], and long-duration natural-clay tests near yield reveal time-sensitive behaviour [33]. Rheological consolidation experiments and analyses require hydraulic, loading-history and constitutive parameters to be specified [34]. Four-specimen Nanjing oedometer tests likewise report stress-dependent secondary compression under a stated deformation-rate criterion [35]. These mechanisms cannot be represented merely by replacing one constant with a more flexible terminal loading curve.
The square-root joining expression used in the present family can be traced to the 2023 Simplified Silty Sand model of Kaewhanam and Chaimoon, where it described a curved critical-state relation in mean-effective-stress coordinates before the name Arc Joint via Optimum Parameters (AJOP) was used [36]. Subsequent work applied an AJOP formulation to oedometer-based consolidation settlement [37] and used the related AJOP-T map as a hardening law [38]. These applications establish the equation lineage, not equivalence between mean stress, vertical stress and a hardening coordinate. Here the generalized family includes a nonnegative low-stress slope and is tested on explicitly identified one-dimensional laboratory coordinates.
A separate geological CO₂-storage application is publicly available as a non-peer-reviewed preprint [39]. It reports useful complete-window approximation by AJOP, including selected improvements over a log-linear law, while also documenting lower errors from competing curves and failures under blocked prediction. Its relevance is the separation of approximation, parameter identification and engineering-output assessment; it is not independent evidence for a foundation model. Even within oedometer testing, inferred preconsolidation stress depends on interpretation method and the largest included stress [40]. A fitted transition coordinate should therefore not automatically be identified with an independently measured yield stress.
The evidence used to evaluate a simplification must match the question being asked. Published Manitoba and Randers programmes supply reconstructed compression curves together with pile-related observations [41,42]. Su et al. provide six additional tabulated compression curves from deep Haihe cohesive soils, while their field-equivalent modulus calculation also depends on reconstructed stresses and regional corrections [43]. Bayesian updating of embankment settlement offers another route for combining prior and monitoring information [44]. These approaches differ in what is observed, inferred or imposed. A smaller calibration residual cannot by itself determine whether an extra parameter changes the engineering decision, and agreement between numerical implementations is distinct from validation for an intended use [45].
This study formulates that decision as an intersection of output-specific coefficient intervals and a dimensionless tolerance-normalized index. The finite-stiffness comparison result propagates ordered strain envelopes through fixed monotone shaft and toe laws. Its practical motivation is the masking effect of head load: acceptance based on total maximum force can conceal excessive relative error in the drag increment. Synthetic cases quantify this effect and distinguish an adequate simplification from an unresolved envelope or an incompatible reference response. Nine laboratory curves test compression approximation, prediction over withheld stress levels and shape restrictions; the Bangkok reconstruction tests a transfer premise across monitored stages. The complete fit diagnostics are retained in Appendix A, with extended applicability and provenance analyses in S1.

2. Materials and Methods

2.1. Evidence Structure and Scope

Table 1 organizes the core evidence around the decision sequence. Published Manitoba and Randers programmes supply three reconstructed laboratory curves with 25 loading markers [41,42]. Six tabulated Haihe curves add 66 positive-pressure entries [43]. The nine curves span three programmes with different reporting conditions. Five hundred frozen synthetic configurations test the coupled response decision, and two Bangkok piles provide a monitored stage-transfer check [46]. Extended analyses of Tokyo monitoring [47], open static-load-test data [48,49,50], a sand–aluminum interface experiment [51], composite-foundation and groundwater-rise studies [52,53], and the Cai Mep building history [54] are retained in S1. They document applicability and provenance rather than enlarge the core prediction sample.
Figure-reading tolerances are deterministic analyst-selected reconstruction bounds. Instrument accuracy, specimen variability and statistical confidence require different evidence. The numerical audit reuses the recorded observations to verify calculation and optimization. S1 separates source measurements, reconstructed coordinates, assumptions and computed outputs, and supplies a portable headline-reproduction command.

2.2. Compression Variables and the AJOP Candidate Family

Let z increase downward, let vertical engineering compression be positive, and let σ₀′(z) and σ₁′(z) denote the initial and final effective vertical stresses on a specified monotone loading path. For void ratio e and its local natural-logarithmic slope λₜ, the strain relative to the initial state is
λ t = − de d ln σ ′ ,     ε z = e 0 z − e 1 z 1 + e 0 z = 1 1 + e 0 z ∫ ln σ 0 ′ z ln σ 1 ′ z λ t   d ln σ ′ .
Here the prime denotes effective stress, not differentiation. When the published ordinate is engineering strain F relative to the original laboratory height, a new increment beginning at F₀ requires a different denominator. A slope reported per base-10 logarithm must also be converted consistently:
ε = F 1 − F 0 1 − F 0 ,     λ = 1 + e ref C ε , 10 ln 10 .
Cε,10 denotes a strain slope per log₁₀ stress at the same reference state. For a void-ratio compression index Cc, λ = Cc/ln 10. A strain slope is not a void-ratio slope unless the reference void ratio is known. This distinction is essential for Randers, whose plotted ordinate is strain; no unreported void ratio is assigned to that specimen.
The square-root transition appears in Equation (3) of the Simplified Silty Sand model [36], where the stress variable is mean effective stress. Phonchamni et al. subsequently applied an AJOP formulation to oedometer-based consolidation settlement [37]. The present centered generalized family adds a nonnegative low-stress baseline slope. With u = ln(σ′/pᵣ), λ∞ ≥ λ₀ ≥ 0, and θ > 0,
e σ ′ = e r − λ 0 u − λ ∞ − λ 0 2 u + θ + u 2 − θ .
λ t u = λ 0 + λ ∞ − λ 0 2 1 + u θ + u 2 ,     λ 0 ≤ λ t ≤ λ ∞ .
For a positive SSS slope parameter α and θSSS > 0, the earlier square-root expression is recovered algebraically with λ₀ = 0, λ∞ = 2α, θ = θSSS/α² and eᵣ = Γ − √θSSS [36]. The curvature parameters have different scaling; the mean-effective-stress and vertical-effective-stress coordinates are not physically interchangeable. This lineage statement does not assert global priority for square-root smoothing functions.
The square-root transition has a nondecreasing logarithmic compression slope, a restriction tested against each observed stress window. The algebraic form of the published AJOP-T map is recovered with λ₀ = 0, λ∞ = 2ac, and eᵣ = Γ − ac√θ [38]. AJOP-T uses a hardening-pressure coordinate; Equation (3) applies the generalized shape to a one-dimensional vertical-stress loading path. AJOP in the figures denotes this defined family. The transition stress pᵣ is a fitting coordinate; identifying it with preconsolidation stress or interpreting fitted asymptotes physically requires additional evidence. Controlled tests show that the included stress range affects interpreted preconsolidation pressure [40]. Bound-hitting optima are reported explicitly and are not treated as proof that the parameters are physically identified.

2.3. Reconstruction, Fitting, and Independent Numerical Audit

The Manitoba reconstruction uses vector marker coordinates from the published compression plot, with eight initial-loading markers per specimen. Six unloading/reloading markers per specimen are retained separately. The initial-loading range is approximately 16.5–2936 kPa. Assigned reading bounds are ±0.0015 in void ratio and ±0.01 in log₁₀ stress. The Randers reconstruction uses nine initial-loading marker centres over approximately 4.97–1190 kPa, with bounds of ±0.003 strain and ±0.015 in log₁₀ stress. Branch connectivity and ordinate units are preserved in the supplied extraction records.
For fitting, x = ln(σ′/kPa) and compression-positive F is −e for Manitoba and laboratory engineering strain for Randers. The fitted expression is algebraically equivalent to Equation (3), with a free ordinate at a reference x₀:
F x = a + c 0 x − x 0 + Δ c 2 x − x 0 + θ + x − q 2 − θ + x 0 − q 2 .
Here q = ln(pᵣ/kPa), Δc ≥ 0, and c∞ = c₀ + Δc. The original fit minimizes unweighted vertical squared residuals at the reconstructed stresses using 16 starts. Parameter bounds for (a, c₀, Δc, q, ln θ) are (−2, 0, 0, −12, −14) to (2, 2, 4, 22, 16). These bounds define a numerical search domain, not a physical prior. Constant and bilinear compression fits provide reference families with two and four parameters; AJOP has five. No information criterion or statistical significance test is inferred from these small digitized samples.
An independent implementation rationalizes the square-root difference and separates two nonlinear parameters from three bounded linear coefficients. Differential-evolution searches using three seeds, followed by least-squares polishing, check the original least-squares objective. A separate minimax search uses linear programming for the largest absolute ordinate residual and two nonlinear search seeds. Agreement between implementations is numerical verification; neither search proves global optimality. Horizontal reading uncertainty is displayed and used in the secant shape test, but the fitting objectives hold reconstructed stresses fixed. Thus the fits are not errors-in-variables likelihood analyses.
A retrospective Randers stress-window holdout fits the first seven markers and predicts the last two. These are withheld stress levels from one specimen, not independent specimens or a blind field validation. All four original parameterizations are retained: Manitoba 11 m, Manitoba 23 m, the full Randers curve, and its seven-point fit. All original fit views, including residuals, branch diagnostics, and the independent objective comparison, appear in the main text or Appendix A.

2.4. Finite-Stiffness Pile Model and Conditional Ordering

For a pile of length L, let N(z) be positive compressive axial force, w(z) downward pile displacement, S(z) free-field soil settlement, p(z) perimeter, and EA(z) axial rigidity. The shaft shear stress T is positive when the soil moves downward relative to the pile; pT is force per unit pile length. The base datum is S(L); soil settlement at depth z equals this base settlement plus the integrated strain below z. The equilibrium and compatibility problem is
dN dz = p z T z , S − w ,     dw dz = − N EA z , N 0 = P ,     N L = B w L − S L .
The applied head load P, rigidity, geometry, shaft law T, toe law B, and settlement datum S(L) are held fixed within each compression comparison. T and B are memoryless, single-valued, monotone increasing functions of their relative movements; the demonstrated smooth model uses a tanh shaft law and a linear toe spring. Comparisons involving a changed effective-stress capacity, interface stiffness, residual state, or loading history are outside this fixed-law statement. Existence and sufficient regularity of the compared solutions are assumed, with strictly positive tangent response for the elementary comparison proof; limiting plateau cases require a suitable well-posed limit.
If ε₋(z) ≤ ε(z) ≤ ε₊(z), and settlement is integrated from the same base datum, the finite-stiffness comparison gives pointwise force and pile-displacement ordering:
N−(z) ≤ N(z) ≤ N+(z),  w−(z) ≤ w(z) ≤ w+(z).
A proof using force differences and a negative-part test is given in Appendix B. Ordered soil displacement profiles alone are insufficient for the stated proof; the ordering is in strain, or equivalently in the derivative of the soil-settlement profile. The theorem does not order the location of the maximum force or the depth where S = w. Those locations can change non-monotonically even when force and displacement are ordered pointwise.
The response targets are the drag increment D and pile-head settlement W, not two definitions of the same quantity:
D = max   0 , max 0 ≤ z ≤ L N z − P ,     W = w 0 .
Testing total maximum force instead of D can conceal substantial relative drag error when P is large. Each response is therefore reported separately. The numerical examples use positive head settlement and compression loading. Their 10% tolerance is an illustrative analyst choice and is not attributed to a design code.

2.5. Joint Adequacy of One Constant Coefficient

Consider an unknown nonnegative response Q in an outer interval [A, B], with 0 ≤ A ≤ B, and a constant-law prediction Qc. For 0 ≤ τ < 1 and an absolute allowance δ ≥ 0, requiring |Qc − Q| ≤ τQ + δ for every Q in the interval is equivalent to
(1 − τ)B − δ ≤ Qc ≤ (1 + τ)A + δ.
Monotone response to the constant coefficient converts this target interval into a feasible coefficient interval for each output. One coefficient is adequate for drag and settlement together only if those intervals intersect. If several transfer scenarios are enumerated, the same coefficient must lie in the intersection over both outputs and all those scenarios:
C joint = ⋂ s ∈ S C D , s ∩ C W , s .
Within each scenario, the reference and constant models use identical transfer parameters. For the void-ratio examples, the scalar surrogate has εc(z) = λc ln[σ₁′(z)/σ₀′(z)]/[1 + e₀(z)] with fixed local initial states. The inverse search retains the rightmost feasible endpoint on zero-drag plateaux. The inequality |Qc − Q| ≤ τQ with δ = 0 requires zero predicted drag when Q = 0; no division by zero is used. Practical applications should specify a meaningful absolute allowance near zero. All quoted 500-case counts use strict relative tolerance so that the numerical rule is fully reproducible.
A nonempty common interval certifies the stated tolerance for the declared response box within the model and numerical accuracy. An empty intersection for a conservative outer box means that this information cannot certify the simplification. For a prescribed nonlinear reference, disjoint intervals instead demonstrate incompatibility of the constant-law class with that reference. Section 4.1 gives a dimensionless form and the corresponding action in each case. The interval algebra is elementary; the engineering decision requires the same coefficient to satisfy both coupled outputs and every declared transfer scenario.

2.6. Laboratory Point Envelopes and Numerical Experiments

For a monotone laboratory strain curve F, point-reading rectangles give lower and upper functions Fₗ and Fᵤ within the measured stress support. Incremental strain relative to the initial state is bounded by
ε − = max   0 , F l σ 1 ′ − F u σ 0 ′ 1 − F u σ 0 ′ ,     ε + = F u σ 1 ′ − F l σ 0 ′ 1 − F l σ 0 ′ .
The construction requires ordered, admissible observation boxes and 0 ≤ Fₗ ≤ Fᵤ < 1. It does not extrapolate beyond measured support. A second construction adds piecewise-linear interpolation in log stress between uncertain nodes. The latter is an additional shape assumption, not information supplied by more observations. Pointwise extreme strains may not be jointly realizable by one common laboratory curve; the resulting response box can consequently be conservative.
The numerical collection contains 500 frozen parameter sets, with sampling domain and seed reported in Table A2. These are prescribed synthetic benchmarks, so the acceptance counts describe this domain rather than a frequency of successful field designs. The base mesh has 201 nodes; selected conclusions are checked on finer meshes. Transfer tests enumerate 27 combinations of shaft-capacity multipliers (0.5, 1, 1.5), mobilization-slip multipliers (0.5, 1, 2), and toe-stiffness multipliers (0.5, 1, 2). These deliberate stress tests describe the enumerated scenarios, not extrema over the continuous parameter box.
Five existing synthetic pile configurations are also subjected to the Randers laboratory envelopes. They are not reconstructions of the Randers pile geometry. In these examples the surrogate coefficient c multiplies ln(σ₁′/σ₀′) in engineering strain; it is not relabelled Cc. Fixed depth, stress profiles, and geometry are retained, so cases with large calculated strains illustrate the algorithm rather than validate a small-strain physical approximation.
AJOP is used in the synthetic collection because its prescribed slope bounds, transition location and width give a controllable nonlinear benchmark. The parameter draws in Table A2 are independent of the laboratory calibrations in Table A1. The synthetic reference is known by construction within this model; it is not selected as a validated soil law. The interval procedure also accepts laboratory point envelopes and does not require an AJOP reference. Each synthetic case uses a homogeneous slope function with locally anchored initial states, rather than imposing one global e(σ′) curve at all depths. Frozen inputs, mesh checks and executable analyses are supplied in S1.

2.7. Tabulated Haihe Curves and Blocked Prediction

The two-page supplement of Su et al. contains specimens D2-18–D2-23, each with eleven positive nominal pressures of 50, 100, 200, 300, 400, 500, 600, 800, 1000, 1200 and 1600 kPa and void ratios printed to three decimal places [43]. All 66 entries were transcribed and independently checked against both source pages. Duplicate zero-pressure entries are retained once as reference states and excluded from logarithmic fitting. The D2-20 table has a different printed identifier from its adjacent graph, and D2-22 has a depth typographical ambiguity; both are recorded in S1 and neither affects fitting. Test duration, drainage completion, specimen height and pore pressure are not reported in the inspected source material. Consequently, p is treated as nominal applied pressure, not independently verified equilibrium effective stress.
The same generalized algebraic family is fitted to void ratio against x = ln(p/kPa), anchored at x₀ = ln 50. The parameter vector is (a, c₀, Δc, q, ln θ), where a is the fitted void ratio at 50 kPa. Bounds remain (−2, 0, 0, −12, −14) to (2, 2, 4, 22, 16). Each least-squares search uses 32 starts and is checked with a separate two-dimensional variable-projection search: bounded linear coefficients are solved at each (q, ln θ), which are searched by differential evolution. S1 gives seeds, solver tolerances, all parameter sets and predictions. These checks establish numerical agreement within the searched domain, not global optimality or physical identification of asymptotes.
Comparators are a two-parameter constant logarithmic slope and a continuous four-parameter bilinear law with nonnegative low slope and nonnegative slope increment. The bilinear breakpoint is searched within the calibration stress range. Full-window fits use eleven points. A separate retrospective blocked test fits only the first nine points, 50–1000 kPa, and evaluates the two withheld observations at 1200 and 1600 kPa. No withheld ordinate enters an optimizer. Errors are unweighted void-ratio RMSE and maximum absolute residual; the six pairs of held-out points are not twelve independent specimens. The comparator restrictions and parameter counts are reported because improved calibration with added flexibility is not, on its own, validation [45].
A separate shape test minimizes the largest ordinate residual over every nonincreasing concave sequence in log pressure, using linear programming. Successive void-ratio secants must therefore be nonincreasing. Because every admissible AJOP curve has this property, the relaxed optimum is a lower bound on the AJOP minimax residual, independent of the nonlinear optimizer. Three-point chord defects provide a separate analytical check of the active lower bounds. The bound is compared with ±0.0005 only as an assumed nearest-rounding band for the printed values. That band is neither measurement uncertainty nor a confidence interval. A lower bound exceeding it rejects exact compatibility with the declared shape and rounding assumptions; it does not reject approximate use over a narrower pressure interval.

3. Results

3.1. What the Laboratory Fits Establish

Figure 1 compares the full initial-loading fits and residuals; Table 2 gives their errors. An independent least-squares implementation reproduces the original objectives to within 5 × 10⁻¹⁴ relative difference in summed squared residuals. The Manitoba 11 m fit lies within its selected ordinate-reading band; Manitoba 23 m and the full Randers fit exceed theirs. Both Manitoba fits approach the zero lower-slope bound, and the full Randers fit reaches the lower transition-width bound. These solutions support assessment of approximation over the observed window. They do not establish physical identification of the unobserved asymptotes or transition parameters.
Least-squares and minimax fitting answer different questions. The seven-point Randers least-squares maximum residual slightly exceeds ±0.003 strain, while the independently searched minimax fit lies inside that ordinate band at the fixed reconstructed stresses. Thus a least-squares miss is not proof that no AJOP curve can fit within the band. For Manitoba 23 m and full Randers, the searched minimax residuals remain above their selected bands. These optimization results remain numerical searches, not global nonexistence proofs.
The seven-point Randers fit misses its two withheld high-stress markers by up to 4.631 percentage points of strain (Figure 2). The minimax calibration gives a comparable held-out maximum of 4.604 percentage points. The additional flexibility of the fit therefore does not remove the observed stress-window extrapolation problem. The training/holdout split tests transfer along one specimen curve and cannot be counted as a new field or laboratory experiment.
The shape check is independent of optimization. Consecutive Randers secant slopes over approximately 79–295 and 295–1190 kPa are 0.30528 and 0.23430 strain per log₁₀ stress. Allowing the stated horizontal and vertical reading boxes gives intervals [0.28010, 0.33325] and [0.21378, 0.25695]. Their strict separation excludes a globally nondecreasing logarithmic slope over this measured window at the stated reading level. It does not exclude approximation over a narrower field stress path. Figure 3 separates analytical tangent slopes from observed secants; secants must not be treated as measured asymptotic bounds.
The separate Manitoba unloading/reloading plot in Appendix A shows why a single memoryless function of stress cannot be used for both branches. These points were never included in the initial-loading objective. A field loading path involving unloading, reloading, or creep needs an appropriate state or branch description before the compression envelope is propagated.

3.2. Joint Force and Settlement Decisions

Head-load masking changes outer-envelope certification. At the same joint 10% tolerance, 105 of the 500 frozen cases certify the total-maximum-force and settlement envelopes, whereas 76 certify the drag-increment and settlement envelopes. All 76 drag-based certificates are contained in the total-force set. The difference is 29 cases, or 27.62% of the 105 total-force certificates, within this selected numerical collection. For a positive reference drag D, define relative prediction errors EΣ for total maximum force P + D and ED for drag alone. With the same head load P in both compared solutions, the exact relation is
E Σ = E D 1 + μ ,     μ = P D ,     D > 0 .
Equivalently, a relative total-force allowance τ permits |Dc − D| ≤ τD + τP: the head load supplies an additional absolute allowance τP for drag error. This inequality also avoids division by zero. The 29 cases lose certification against the outer response box when the output definition changes; all 29 still admit a constant matching their particular synthetic AJOP reference within 10%. They must therefore not be counted as 29 demonstrated prediction failures. In the full collection, 496 cases match their prescribed synthetic reference. Thirty-one reference responses and 58 lower-envelope responses have zero drag. Table 3 separates these decisions.
Figure 4 summarizes selected comparisons. Case 31 has a slope ratio of 7.27464, yet its drag envelope is 273.802–303.672 kN and its head-settlement envelope is 2.88862–2.96761 mm. A common coefficient of 0.07037594 gives a worst joint error of 5.17242%; the approximate 10% feasible interval is [0.04112941, 0.19817807]. A large constitutive slope ratio is therefore not, by itself, evidence that one constant gives unacceptable pile-response error.
Case 100 provides a contrasting response decision. On the 1601-node mesh, the prescribed synthetic nonlinear reference gives drag 163.5861 kN and head settlement 139.3502 mm. Matching drag within 10% requires λc approximately in [0.01309, 0.01392], while settlement requires [0.01575, 0.02159]. Their disjointness prevents a shared coefficient. The best common coefficient, 0.014173974, has joint error 16.12426%. Refinement from 201 to 401, 801 and 1601 nodes gives 16.11909%, 16.12349%, 16.12410% and 16.12426%; the incompatibility is much larger than the observed mesh change. Its slope range, 0.00471035–0.02924981, is part of the declared Table A2 domain.
Case 9 separates masking from lack of information. With head load 702.1873 kN, its total-force/settlement certificate passes but the best drag/settlement outer-envelope error is 17.2046%. A constant nevertheless matches its prescribed synthetic AJOP response with about 0.1101% joint error. Thus the outer box is insufficient for certification even though the particular synthetic curve can be approximated.
A separate location check illustrates why Equation (7) is not a neutral-plane theorem. In Case 372 on 1601 nodes, the low-bound, AJOP, and high-bound crossings are 7.29861, 13.77638, and 13.11994 m, respectively. The AJOP crossing lies 0.65644 m deeper than the high-bound crossing, while peak forces remain ordered at 111.093, 168.347, and 495.388 kN.

3.3. Sensitivity to Transfer Assumptions and Laboratory Information

For Case 31, 26 of the 27 selected transfer scenarios individually admit a joint 10% outer-envelope certificate, but there is no single coefficient certifying all 27. A constant matching the synthetic AJOP reference response across all 27 still exists, approximately over [0.07120, 0.29920]. The nuisance-only AJOP response width is 10.35 times the compression-only drag width and 40.49 times the compression-only settlement width. Case 477 retains a common coefficient interval, approximately [0.04140624, 0.15862844], across all 27 scenarios; its corresponding width ratios are 20.35 and 69.02. These comparisons show when more compression detail alone cannot remove the dominant response spread. They do not establish site uncertainty magnitudes.
The laboratory-envelope experiment makes the information assumption visible. For synthetic Case 31, five Randers markers with monotonicity alone give a drag envelope of 0–307.7079 kN; all nine markers give 0–306.8998 kN. Neither admits a strict 10% certificate. Adding log-linear interpolation between the same nine uncertain points narrows the drag envelope to 301.0565–305.5789 kN and the settlement envelope to 2.96178–2.97174 mm. A coefficient of approximately 0.07244264 then gives conditional error bounds of 2.323% for drag and 0.536% for settlement. The conclusion changes because the admissible shape class changes, not because new measurements were added. All five selected synthetic configurations show this distinction.
The zero lower-strain corner in the monotonicity-only construction need not correspond to one jointly realizable laboratory curve. This explains part of the conservatism and reinforces the distinction between lack of certification and actual surrogate failure. Refining the step-envelope calculation through 6401 nodes leaves the no-certificate conclusion unchanged; the upper drag converges to approximately 306.894 kN. These are finite-grid numerical bounds, not interval-arithmetic guarantees against every discretization error.

3.4. Bangkok Stage-Transfer Check

The Bangkok reconstruction contains 67 plotted force coordinates across five times and two piles, including ten head-boundary anchors and 57 interior markers. Twenty-one shallow soil-settlement markers are resolved individually; fourteen deep entries are common overlap intervals. Figure 5 shows a simple stage-shape test. Scaling the day-25 profile to match the day-265 surface settlement predicts 104.67 mm at 4 m, compared with 157.04 mm reconstructed from the later profile. Propagating ±5 mm reading bounds leaves a minimum gap of 27.64 mm. At 10 m the corresponding reading intervals overlap. The result challenges a fixed depth shape scaled by one amplitude, without identifying which physical mechanism changed the shape.
A separate reduced forward test fits three shaft-capacity zones, a toe spring, and one unresolved deep-settlement parameter to six nonboundary day-25 force markers per pile. The tanh slip scale is 3 mm; it is not an exact reproduction of the source interface law. Training RMSE is 4.392 kN for T1 and 3.606 kN for T2, and both fitted deep-settlement parameters reach their imposed 12 mm upper bound. This is a weakly identified calibration, not independent measurement of transfer properties.
Using the day-265 shallow settlement profile with the frozen transfer parameters and scanning 49 selected deep-settlement states gives withheld force-profile RMSE of 117.04–132.83 kN for T1 and 22.52–38.52 kN for T2 (Figure 6). None of the eleven withheld interior reading intervals intersects the resulting model envelope. Refinement from 271 to 1081 nodes changes the checked predictions by at most 0.287 and 0.191 kN. The large disagreement is therefore not explained by the tested mesh spacing. It rejects this selected reduced surrogate across stages; it does not reject every monotone transfer law or isolate compression-law error. Parameter nonuniqueness, evolving capacity, residual state, and unresolved deep movement are outside the scanned envelope.

3.5. Tabulated Compression Comparisons

Table 4 and Figure 7 report the six Haihe curves without graph digitization. AJOP gives smaller full-window RMSE than the constant-log-slope comparator for all six specimens: 0.000321–0.002501 versus 0.002152–0.010704 in void ratio. Its held-out RMSE in the 9 + 2 blocked tests is also smaller in all six: 0.000877–0.009558 versus 0.003869–0.019222. This improvement is demonstrated for the specified nominal-pressure curves and withheld levels within one source programme.
Against the constrained bilinear model, AJOP has smaller blocked error in four specimens, is numerically indistinguishable for D2-22, and has larger error for D2-20: 0.009558 versus 0.004668. Four full-window fits approach the zero lower-slope bound, and D2-22 reaches the lower transition-width bound. Direct and variable-projection searches agree within 3.4 × 10⁻¹² relative summed-squared-residual difference across the twelve AJOP calibrations. This establishes numerical agreement between the searches, rather than a proof of global optimality or physical parameter identification. Figure A6, Figure A7, Figure A8, Figure A9, Figure A10 and Figure A11 preserve every fit, residual and blocked prediction.
Shape compatibility is a separate test. The relaxed minimax lower bounds are 0.003750 for D2-20 and 0.000772 for D2-22, exceeding the assumed ±0.0005 printed-rounding band. Chord defects of 0.007500 and 0.001544 at pressure triplets (400, 800, 1600) and (200, 500, 1200) kPa reproduce these bounds analytically. Both curves therefore conflict with an everywhere nondecreasing logarithmic slope at that declared precision. Their useful approximation by AJOP and their stricter shape failure can coexist. Selection for a field stress interval requires the loading path, pressure interpretation and test protocol to be specified.

4. Discussion

4.1. A Dimensionless Decision for One Shared Coefficient

The design question has a dimensionless, response-based answer. Let Q denote drag D or settlement W in scenario s, with nonnegative reference interval [AQ,s, BQ,s], relative allowance 0 ≤ τQ < 1 and absolute allowance δQ ≥ 0. The interval has a scalar width screen
κ Q , s = B Q , s − A Q , s τ Q A Q , s + B Q , s + 2 δ Q .
A single unrestricted output value can satisfy the entire interval exactly when κQ,s ≤ 1. This screen follows directly from Equation (9): the target interval must have nonnegative width. It is necessary for a constant compression model, but separate passes for drag and settlement do not ensure a common coefficient. With Λ a declared nonempty compact coefficient range and continuous constant-model responses, the joint dimensionless index is
R * = min λ c ∈ Λ max Q , s max q ∈ { A Q , s , B Q , s } Q c , s λ c − q τ Q q + δ Q .
Here Qc,s is the constant-law response and the maximum is over Q ∈ {D, W} and the declared scenarios. In both Equations (13) and (14), set 0/0 = 0 and a positive number divided by zero to infinity; an absolute allowance is preferable near zero in applications. The largest normalized error over a nonnegative interval occurs at an endpoint, so R* ≤ 1 is equivalent to a nonempty joint coefficient intersection. A value above one against an outer box means insufficient certification; against a known reference, obtained by setting A = B, it demonstrates incompatibility with that reference. For the reported τD = τW = 0.10 and δD = δW = 0, the Case 31 outer envelope has R* = 0.51724 and the refined Case 100 known reference has R* = 1.61243. These values are computed from the already reported joint errors. A global material slope ratio cannot replace this response-dependent index.
The storage application provides a useful comparison of assessment levels [39]. Its P13 complete-window normalized RMSE decreases from 0.48% for a log-linear law to 0.17% for AJOP, while a quadratic has lower full-data error in 14 of 19 trajectories and blocked tests expose extrapolation failures. These results are reported in a non-peer-reviewed preprint. Here the additional decision is whether one coefficient meets simultaneous force and settlement tolerances under the same transfer assumptions.

4.2. What Additional Evidence Can Change

The laboratory experiment shows why acquisition and modelling assumptions should be separated. Additional observations within a relevant transition interval can constrain the compression path, but smooth interpolation can also narrow an envelope without adding data. Neither a plotted endpoint secant nor a fitted asymptote should be presented as a measured global tangent bound. Tests should cover the actual field stress interval and relevant unloading, reloading, and time dependence. Replicate depths and specimens are needed to assess variability that figure-reading bounds cannot represent.
The transfer-scenario results identify where investigation can be more valuable than a more flexible compression fit. If the transfer-induced response spread dominates the compression-induced spread, independent shaft/toe information, residual stress and monitored construction stages deserve priority. The Bangkok check exposes a cross-stage discrepancy even with the prescribed settlement scan. The extended Tokyo and open-database audits in S1 identify displacement-reference and branch-history requirements that should be checked before applying the same procedure.
The added data also clarify what should be measured next. Nanjing tests report a deformation-rate stopping criterion and stress-dependent secondary compression [35], whereas those protocol details are absent for the tabulated Haihe curves. Interpretation tests show that maximum applied stress changes the inferred preconsolidation pressure [40]. Time records, drainage conditions, stress support and raw branch labels are therefore useful additions to a laboratory programme. A nonlinear consolidation model with constant Cc may already address variable permeability and geometry [31]; evidence is needed to decide whether compression curvature, hydraulic parameters or transfer uncertainty controls the target output.

4.3. Application to Building Foundations

For a building-foundation assessment, first specify the construction stage, effective-stress path and relevant loading history. Use the drag increment and pile-head settlement as separate response targets, with tolerances and an absolute allowance near zero. Obtain admissible compression bounds over that path, declare the transfer scenarios and compute the common coefficient interval. Table 5 gives the resulting action. Loading reversals and time-dependent response require suitable branch or state descriptions [24,32,33,34]; the fixed-law comparison applies only within its stated history and transfer domain.

4.4. Evidence Limits and Relation to Existing Methods

The procedure evaluates compression simplification within a single-pile forward model. A building-level extension must also represent raft contact, pile-group interaction, differential settlement and construction-stage load redistribution, as illustrated by monitored piled rafts [7,8]. The Tokyo, database, composite-foundation and drainage examples in S1 retain the broader applicability evidence without treating their different observables as extra tests of the core prediction chain.
Deformation-compatible pile analyses evaluate soil–pile movement with mobilized shaft and toe resistance [21,22], and consolidation–pile models include nonlinear creep and drainage effects [23,24]. The present procedure evaluates a specified simplification within a declared forward model: whether one constant coefficient meets both response tolerances. Its contribution is the operational joint decision and the tests that establish where its premises apply. Source-access and reading-coverage records are supplied in S1. The current laboratory and field checks support approximation and applicability assessment; an independently calibrated, held-out prediction of the complete compression-to-drag-and-settlement chain remains outside the demonstrated evidence.

5. Conclusions

Checking drag increment separately from total maximum force changes outer-envelope certification. In the 500 frozen synthetic configurations, 29 of 105 joint total-force/settlement certificates are lost under the drag/settlement requirement at the same illustrative 10% tolerance. The head load acts as an additional drag-error allowance when total force is used. These are losses of certification over a response box; each of the 29 cases still admits a constant matching its prescribed synthetic reference within 10%. The count describes the declared sampling domain. The additional allowance τP applies under identical head loads, including zero drag; the normalized identity in Equation (12) requires D > 0.
One constant is adequate for the declared response box when the common coefficient interval is nonempty, equivalently when the tolerance-normalized index R* is at most one. The Case 31 outer envelope gives R* = 0.51724 despite a 7.27 slope ratio; the refined Case 100 known reference gives R* = 1.61243. Seventy-six cases certify the outer drag/settlement box, whereas 496 match their prescribed synthetic nonlinear reference. These tests distinguish a conservative information limit from incompatibility with a specified response.
The nine laboratory curves provide complementary evidence on approximation, shape and prediction. Independent computation reproduces the four original AJOP least-squares fits. Randers fails the declared nondecreasing-slope shape test over its observed window, and its seven-point fit misses withheld stresses by up to 4.63 percentage points of strain. Boundary parameter estimates are retained as numerical results rather than interpreted as identified physical asymptotes.
For the six tabulated Haihe curves, AJOP reduces full-window and blocked-test RMSE relative to a constant logarithmic slope in every specimen. Against the constrained bilinear comparator, the blocked comparisons comprise four improvements, one numerical tie and one adverse result. Two specimens fail the assumed printed-precision shape test. Together these outcomes support evaluating the approximation needed over the actual stress interval rather than selecting a nonlinear law from calibration error alone.
The practical sequence is to specify drag and serviceability tolerances, screen the response widths, find one coefficient shared by both outputs and all declared scenarios, and direct further investigation to the information preventing that decision. Compression-path measurements, transfer characterization or a history-dependent model may be needed in different cases. Under the theorem’s fixed-law hypotheses, ordered strain bounds provide force and displacement bounds; neutral-plane locations require a separate check.

Supplementary Materials

The following supporting information can be downloaded at the website of this paper posted on Preprints.org. S1 contains supporting applicability analyses (Figures S1–S3 and Tables S1–S2), a portable numerical reproduction package, frozen inputs and reference outputs, source-reading and provenance records, complete numerical tables and figure-generation code. It is self-contained and does not require an earlier archive.

Author Contributions

Conceptualization, C.C., N.K. and T.C.; methodology, N.K.; formal analysis, C.C., N.K. and T.C.; software, N.K.; validation, C.C., N.K., A.K., S.E.-a. and S.S.; investigation, S.I.; resources, T.C., S.I. and S.S.; data curation, T.C., S.I. and S.S.; writing—original draft preparation, C.C. and N.K.; writing—review and editing, N.K., T.C., S.I., A.K., S.E.-a. and S.S.; visualization, A.K. and S.E.-a.; supervision, A.K., S.E.-a. and S.S.; project administration, N.K.; funding acquisition, N.K.

Funding

This research project was financially supported by Mahasarakham University.

Institutional Review Board Statement

Not applicable.

Data Availability Statement

No new physical experiments were performed. Supplementary Material S1 contains the recorded observations, assumptions, executable code and calculated results used in this study. Primary observations are attributed to their publications. The open pile-test database is available from DesignSafe-CI, version 2, https://doi.org/10.17603/ds2-bez6-4812, under the Open Data Commons Attribution License. S1 documents the retrieved subset, exclusions and source-reading coverage.

Acknowledgments

During the preparation of this work, the authors used Claude (Anthropic) and ChatGPT (OpenAI) to assist with manuscript editing and language refinement and with drafting scripts for figure preparation and numerical cross-checking. All scientific content, mathematical formulations, calculations, results, interpretations, and conclusions were independently developed, reviewed, and verified by the authors. The authors subsequently reviewed and edited all AI-assisted content and take full responsibility for the content of the published article.

Conflicts of Interest

The authors declare no conflicts of interest.

Abbreviations

AJOP Generalized AJOP compression family defined by Equation (3)
BVP Boundary-value problem
EA Pile axial rigidity
LS Least squares
NSF Negative skin friction
RMSE Root mean square error

Appendix A. Complete Fit Diagnostics

Figure A1, Figure A2 and Figure A3 show each full initial-loading fit at a larger scale than the overview. Figure A4 retains every reconstructed Manitoba unloading/reloading marker separately from the fitted loading branch. Figure A5 compares the original least-squares solution, the independent least-squares implementation, and the independently searched minimax objective for all four parameterizations. Parameter records and marker-level residuals are supplied in Supplementary Material S1. Table A1 lists all four frozen parameterizations.
Table A1. Frozen least-squares parameters. Slopes are per natural-log stress. The reference ordinate is eᵣ for Manitoba and Fᵣ for Randers; strain values are fractions. These fit values are not independently identified physical asymptotes.
Table A1. Frozen least-squares parameters. Slopes are per natural-log stress. The reference ordinate is eᵣ for Manitoba and Fᵣ for Randers; strain values are fractions. These fit values are not independently identified physical asymptotes.
Fit Ordinate Low slope High slope pᵣ (kPa) θ Reference ordinate
Manitoba 11m e 1.4978e-20 0.0655919 174.313 2.25371 0.444851
Manitoba 23m e 2.1378e-29 0.0513515 193.859 2.47489 0.434862
Randers 2p6m strain 0.027149 0.116561 35.2439 8.31529e-07 0.0706341
Randers 2p6m first7 holdout strain 0.02617 0.134328 43.9013 0.102747 0.0904178
Figure A1. Manitoba 11 m initial-loading fit and residuals. The fitted low-stress slope approaches its zero lower bound; this numerical result is not a physical assertion of zero low-stress compressibility. Source observations: [41]. (a) Loading fit; (b) residuals.
Figure A1. Manitoba 11 m initial-loading fit and residuals. The fitted low-stress slope approaches its zero lower bound; this numerical result is not a physical assertion of zero low-stress compressibility. Source observations: [41]. (a) Loading fit; (b) residuals.
Preprints 239163 g0a1
Figure A2. Manitoba 23 m initial-loading fit and residuals. The maximum least-squares residual exceeds the selected ±0.0015 void-ratio reading band. Changing the triangle-marker centre convention is too small to explain the residual pattern after the free intercept adjusts. Source observations: [41]. (a) Loading fit; (b) residuals.
Figure A2. Manitoba 23 m initial-loading fit and residuals. The maximum least-squares residual exceeds the selected ±0.0015 void-ratio reading band. Changing the triangle-marker centre convention is too small to explain the residual pattern after the free intercept adjusts. Source observations: [41]. (a) Loading fit; (b) residuals.
Preprints 239163 g0a2
Figure A3. Randers full initial-loading fit and residuals. The least-squares transition width reaches its numerical lower bound and approximates a bilinear transition. The ordinate is engineering strain, not void ratio. Source observations: [42]. (a) Loading fit; (b) residuals.
Figure A3. Randers full initial-loading fit and residuals. The least-squares transition width reaches its numerical lower bound and approximates a bilinear transition. The ordinate is engineering strain, not void ratio. Source observations: [42]. (a) Loading fit; (b) residuals.
Preprints 239163 g0a3
Figure A4. All twelve reconstructed Manitoba unloading/reloading markers, separated from the sixteen initial-loading markers. The loading fits were not calibrated to these branch points. Connectivity follows the published plot; raw stage times are unavailable. Source observations: [41]. (a) Manitoba 11 m; (b) Manitoba 23 m.
Figure A4. All twelve reconstructed Manitoba unloading/reloading markers, separated from the sixteen initial-loading markers. The loading fits were not calibrated to these branch points. Connectivity follows the published plot; raw stage times are unavailable. Source observations: [41]. (a) Manitoba 11 m; (b) Manitoba 23 m.
Preprints 239163 g0a4
Figure A5. Original and independently computed least-squares fits, and independently searched minimax fits, for all four parameterizations. Least-squares coincidence checks numerical implementation. Minimax minimizes the largest ordinate error at fixed reconstructed stresses. Neither search certifies a global nonlinear optimum; the Randers holdout points remain excluded from seven-point calibration. Source observations: [41,42]. (a) Manitoba 11 m; (b) Manitoba 23 m; (c) full Randers; (d) seven-point Randers with holdout.
Figure A5. Original and independently computed least-squares fits, and independently searched minimax fits, for all four parameterizations. Least-squares coincidence checks numerical implementation. Minimax minimizes the largest ordinate error at fixed reconstructed stresses. Neither search certifies a global nonlinear optimum; the Randers holdout points remain excluded from seven-point calibration. Source observations: [41,42]. (a) Manitoba 11 m; (b) Manitoba 23 m; (c) full Randers; (d) seven-point Randers with holdout.
Preprints 239163 g0a5
Figure A6, Figure A7, Figure A8, Figure A9, Figure A10 and Figure A11 show the six tabulated Haihe specimens. Every full-window fit, residual and blocked 9 + 2 prediction is retained. The ±0.0005 band indicates assumed nearest-rounding precision of published void ratios, not experimental uncertainty. All curves use nominal applied pressure because drainage completion and pore pressure were not reported [43].
Figure A6. D2-18 tabulated compression diagnostics. (a) Eleven-point full-window fits; (b) full-window residuals; (c) nine-point calibration and predictions at the two withheld high-pressure levels; (d) blocked-test residuals, with the withheld errors distinguished. Residuals are predicted minus tabulated void ratio. Constant and constrained-bilinear comparators use the same calibration points. Source: [43].
Figure A6. D2-18 tabulated compression diagnostics. (a) Eleven-point full-window fits; (b) full-window residuals; (c) nine-point calibration and predictions at the two withheld high-pressure levels; (d) blocked-test residuals, with the withheld errors distinguished. Residuals are predicted minus tabulated void ratio. Constant and constrained-bilinear comparators use the same calibration points. Source: [43].
Preprints 239163 g0a6
Figure A7. D2-19 tabulated compression diagnostics. (a) Eleven-point full-window fits; (b) full-window residuals; (c) nine-point calibration and predictions at the two withheld high-pressure levels; (d) blocked-test residuals, with the withheld errors distinguished. Residuals are predicted minus tabulated void ratio. Constant and constrained-bilinear comparators use the same calibration points. Source: [43].
Figure A7. D2-19 tabulated compression diagnostics. (a) Eleven-point full-window fits; (b) full-window residuals; (c) nine-point calibration and predictions at the two withheld high-pressure levels; (d) blocked-test residuals, with the withheld errors distinguished. Residuals are predicted minus tabulated void ratio. Constant and constrained-bilinear comparators use the same calibration points. Source: [43].
Preprints 239163 g0a7
Figure A8. D2-20 tabulated compression diagnostics. (a) Eleven-point full-window fits; (b) full-window residuals; (c) nine-point calibration and predictions at the two withheld high-pressure levels; (d) blocked-test residuals, with the withheld errors distinguished. Residuals are predicted minus tabulated void ratio. Constant and constrained-bilinear comparators use the same calibration points. Source: [43].
Figure A8. D2-20 tabulated compression diagnostics. (a) Eleven-point full-window fits; (b) full-window residuals; (c) nine-point calibration and predictions at the two withheld high-pressure levels; (d) blocked-test residuals, with the withheld errors distinguished. Residuals are predicted minus tabulated void ratio. Constant and constrained-bilinear comparators use the same calibration points. Source: [43].
Preprints 239163 g0a8
Figure A9. D2-21 tabulated compression diagnostics. (a) Eleven-point full-window fits; (b) full-window residuals; (c) nine-point calibration and predictions at the two withheld high-pressure levels; (d) blocked-test residuals, with the withheld errors distinguished. Residuals are predicted minus tabulated void ratio. Constant and constrained-bilinear comparators use the same calibration points. Source: [43].
Figure A9. D2-21 tabulated compression diagnostics. (a) Eleven-point full-window fits; (b) full-window residuals; (c) nine-point calibration and predictions at the two withheld high-pressure levels; (d) blocked-test residuals, with the withheld errors distinguished. Residuals are predicted minus tabulated void ratio. Constant and constrained-bilinear comparators use the same calibration points. Source: [43].
Preprints 239163 g0a9
Figure A10. D2-22 tabulated compression diagnostics. (a) Eleven-point full-window fits; (b) full-window residuals; (c) nine-point calibration and predictions at the two withheld high-pressure levels; (d) blocked-test residuals, with the withheld errors distinguished. Residuals are predicted minus tabulated void ratio. Constant and constrained-bilinear comparators use the same calibration points. Source: [43].
Figure A10. D2-22 tabulated compression diagnostics. (a) Eleven-point full-window fits; (b) full-window residuals; (c) nine-point calibration and predictions at the two withheld high-pressure levels; (d) blocked-test residuals, with the withheld errors distinguished. Residuals are predicted minus tabulated void ratio. Constant and constrained-bilinear comparators use the same calibration points. Source: [43].
Preprints 239163 g0a10
Figure A11. D2-23 tabulated compression diagnostics. (a) Eleven-point full-window fits; (b) full-window residuals; (c) nine-point calibration and predictions at the two withheld high-pressure levels; (d) blocked-test residuals, with the withheld errors distinguished. Residuals are predicted minus tabulated void ratio. Constant and constrained-bilinear comparators use the same calibration points. Source: [43].
Figure A11. D2-23 tabulated compression diagnostics. (a) Eleven-point full-window fits; (b) full-window residuals; (c) nine-point calibration and predictions at the two withheld high-pressure levels; (d) blocked-test residuals, with the withheld errors distinguished. Residuals are predicted minus tabulated void ratio. Constant and constrained-bilinear comparators use the same calibration points. Source: [43].
Preprints 239163 g0a11

Appendix B. Comparison Proof and Imposed-Displacement Special Case

For two existing sufficiently regular solutions of Equation (6), use the same head load, positive bounded rigidity, base settlement, geometry, shaft law, toe law, and fixed material-history state. Suppose the shaft and toe laws vanish at zero relative movement and are strictly increasing on the attained branches, with positive sufficiently bounded secants. Let Δε = ε₂ − ε₁ ≥ 0, ΔS = S₂ − S₁, V = N₂ − N₁, U = w₂ − w₁, and A = EA. The positive shaft secant a includes pile perimeter, and b is the positive toe secant.
V′ = a(ΔS − U),  U′ = −V/A,  V(0) = 0,  V(L) = bU(L).
Because ΔS′ = −Δε and ΔS(L) = 0, elimination of U yields
− V ′ a ′ + V A = Δ ε ,     V ′ L a L + V L b = 0 .
Set V₋ = min(V, 0). Multiplication by V₋, integration by parts, and the boundary conditions give
∫ 0 L V − ′ 2 a + V − 2 A dz + V − 2 L b = ∫ 0 L Δ ε V −   dz ≤ 0 .
The left side is nonnegative, so V₋ = 0 and V ≥ 0. The pile-displacement difference is consequently nonnegative:
U z = V L b + ∫ z L V t A t   dt ≥ 0 .
This establishes pointwise force and displacement ordering. Applying the result twice gives Equation (7). The proof requires ordered strain and common transfer laws; it does not compare arbitrary pointwise-ordered settlement profiles. Perfect-plastic plateaux are outside this positive-secant proof unless a well-posed limiting argument is supplied. At most one equilibrium exists under these hypotheses: subtracting two solutions with identical S and testing their displacement difference gives an integral of A(U′)² + aU² plus bU(L)² equal to zero. This uniqueness statement does not imply a unique zero-slip depth. □
For the implemented tanh shaft law and positive linear toe stiffness, existence follows from a coercive strictly convex energy. For a general non-odd shaft law the potential derivative must preserve the sign convention:
Π w = ∫ 0 L A w ′ 2 2 + Φ z w − S dz + Ψ w L − s b − Pw 0 .
Here sb = S(L), Φ′z(v) = −p(z)T(z, −v) and Ψ′(u) = B(u). For the implemented odd tanh law, −T(z, −v) = T(z, v). The positive linear toe term and rod energy control rigid translation and strain, respectively. A bounded ultimate toe law would require a separate attainable-capacity and existence check. The derivative of relative movement is (S − w)′ = N/A − ε, whose sign need not be fixed; force ordering therefore does not determine crossing locations.
The imposed-displacement special case has uniform e₀, a uniform constant λ, constant stress ratio R > 1, zero base soil settlement, and imposed pile displacement sₚ. Then
ε c = λ ln R 1 + e 0 ,     S c z = ε c H − z ,     z n = H − s p 1 + e 0 λ ln R .
An interior crossing requires λ > 0 and 0 < sₚ < εcH. A missing root must not be replaced by a boundary and called a neutral plane. Under the same imposed displacement, admissible strain envelopes bound a crossing when the endpoint crossing conditions hold. Constant R does not make nonlinear AJOP strain uniform when initial effective stress varies with depth. Only the endpoint constant-law profiles are uniform under the stated conditions. If the admissible class includes the endpoint laws, their response bounds are attained; a strictly transitioning AJOP family approaches its asymptotic slopes rather than attaining them at finite stress.
For reproducibility, Table A2 gives the domain used to generate the frozen synthetic inputs. Uniform draws and uniform draws in logarithmic coordinates are distinguished. Initial stress is σ₀′ = σoff + γ′z, final stress is σ₁′ = σ₀′ + Δσ′, and distributed shaft capacity is C(z) = (pβ)σ₁′. The head load is P = fP∫C(z)dz. The shaft law is pT = C tanh[(S − w)/d], with toe law B = Kb[w(L) − S(L)].
Table A2. Frozen synthetic sampling domain (seed 182018; 500 cases). U denotes a uniform draw in the displayed coordinate.
Table A2. Frozen synthetic sampling domain (seed 182018; 500 cases). U denotes a uniform draw in the displayed coordinate.
Quantity Sampling domain Units
Pile length H U(10, 40) m
Initial stress offset σoff U(5, 30) kPa
Effective unit weight γ′ U(5, 11) kN/m³
Surcharge Δσ′ U(2, 150) kPa
Lower slope λ₀ 10^U(−3, −1.3) void ratio per ln stress
Slope ratio λ∞/λ₀ U(1.1, 8) —
Local initial e₀ U(0.7, 2) —
Transition stress pᵣ 10^U(1, 3) kPa
Transition width θ 10^U(−1, 1) —
Perimeter × β U(0.2, 0.6) m
Axial rigidity EA 10^U(5.5, 7.5) kN
Slip scale d 10^U(−3, −1.5) m
Toe stiffness Kb 10^U(4, 6) kN/m
Head-load fraction fP U(0, 0.7) —

References

  1. Fellenius, B.H. Unified Design of Piled Foundations with Emphasis on Settlement Analysis. In Current Practices and Future Trends in Deep Foundations, Proceedings of the Geo-TRANS Conference, Los Angeles, CA, USA, 27–30 July 2004; DiMaggio, J.A., Hussein, M.H., Eds.; Geotechnical Special Publication 125; ASCE, 2004; pp. 253–275. [Google Scholar] [CrossRef]
  2. National Academies of Sciences; Engineering; and Medicine. Design of Piles for Downdrag. NCHRP Research Report 1112; The National Academies Press: Washington, DC, USA, 2024. [Google Scholar] [CrossRef] [PubMed]
  3. National Academies of Sciences; Engineering; and Medicine. Pile Design for Downdrag: Examples and Supporting Materials; NCHRP Web-Only Document 398; The National Academies Press: Washington, DC, USA, 2024. [Google Scholar] [CrossRef] [PubMed]
  4. Leung, C.F.; Liao, B.K.; Chow, Y.K.; Shen, R.F.; Kog, Y.C. Behavior of Pile Subject to Negative Skin Friction and Axial Load. Soils Found. 2004, 44, 17–26. [Google Scholar] [CrossRef] [PubMed]
  5. Tsuchiya, T.; Kishida, S. Finite Element Analysis on Settlement Process of Buildings due to Pile Downdrag. J. Struct. Constr. Eng. 1990, 416, 135–143. [Google Scholar] [CrossRef] [PubMed]
  6. Poulos, H.G. Piled raft foundations: design and applications. Géotechnique 2001, 51, 95–113. [Google Scholar] [CrossRef]
  7. Reul, O.; Randolph, M.F. Piled rafts in overconsolidated clay: comparison of in situ measurements and numerical analyses. Géotechnique 2003, 53, 301–315. [Google Scholar] [CrossRef]
  8. Zhu, R.; Zhou, F.; Wan, Z.; Deng, S.; Dong, X.; Zhou, Z.; Xing, W. Improving the Performance of Piled Raft Foundations Using Deformation Adjustors: A Case Study. Buildings 2022, 12, 1903. [Google Scholar] [CrossRef]
  9. Wang, Q.; Li, J.; Fang, T.; Yu, S. Database Analysis of Long-Term Settlement Behavior of Pile Foundations in Shanghai Soft Coastal Clays. Buildings 2024, 14, 3334. [Google Scholar] [CrossRef]
  10. Buttling, S.; Fellenius, B.H.; Pinijpol, N. A nine-year case history of monitoring a wide pile group part I. Proc. Inst. Civ. Eng. Geotech. Eng. 2024, 177, 435–447. [Google Scholar] [CrossRef]
  11. Fellenius, B.H. Down-drag on Piles in Clay due to Negative Skin Friction. Can. Geotech. J. 1972, 9, 323–337. [Google Scholar] [CrossRef]
  12. Shibata, T.; Sekiguchi, H.; Yukitomo, H. Model Test and Analysis of Negative Friction Acting on Piles. Soils Found. 1982, 22, 29–39. [Google Scholar] [CrossRef] [PubMed]
  13. Lee, C.J.; Ng, C.W.W. Development of Downdrag on Piles and Pile Groups in Consolidating Soil. J. Geotech. Geoenviron. Eng. 2004, 130, 905–914. [Google Scholar] [CrossRef]
  14. Yan, Y.; Dai, G.; Chen, Z.; Hu, T.; Gong, W.; Shi, C. Experimental Study of Negative Skin Friction of Pile Group Foundations for Offshore Wind Turbines on Artificial Islands. J. Mar. Sci. Eng. 2024, 12, 1386. [Google Scholar] [CrossRef]
  15. Li, D.; Ma, D.; Su, D.; Rao, S.; Wang, W.; Hong, C. Monitoring Axial Force Development in a Super-Long Pile during Construction Using BOFDA and Data Interpretation Approaches: A Case Study. Buildings 2022, 12, 1462. [Google Scholar] [CrossRef]
  16. Kim, H.J.; Mission, J.L.C. Development of negative skin friction on single piles: uncoupled analysis based on nonlinear consolidation theory with finite strain and the load-transfer method. Can. Geotech. J. 2011, 48, 905–914. [Google Scholar] [CrossRef]
  17. Wang, R.; Brandenberg, S.J. Beam on Nonlinear Winkler Foundation and Modified Neutral Plane Solution for Calculating Downdrag Settlement. J. Geotech. Geoenviron. Eng. 2013, 139, 1433–1442. [Google Scholar] [CrossRef]
  18. Russo, G.; Di Girolamo, L.; Marone, G. BEM and FEM Approaches to the Analysis of Negative Skin Friction on Piles. Geotech. Eng. J. SEAGS AGSSEA 2020, 51, 103–110. [Google Scholar] [CrossRef]
  19. Jiang, C.; Shi, Z.; Pang, L. Analytical Solution for Negative Skin Friction in Offshore Wind Power Pile Foundations on Artificial Islands under the Influence of Soil Consolidation. J. Mar. Sci. Eng. 2023, 11, 1071. [Google Scholar] [CrossRef]
  20. Wu, Y.; Ren, Y.; Liu, J.; Ma, L. Analysis of Negative Skin Friction on a Single Pile Based on the Effective Stress Method and the Finite Element Method. Appl. Sci. 2022, 12, 4125. [Google Scholar] [CrossRef]
  21. Ashour, M.; Abbas, A. Mobilized Response of Piles Subjected to Downdrag. Int. J. Geomech. 2021, 21, 06021019. [Google Scholar] [CrossRef]
  22. Shu, S. Deformation-compatible downdrag estimate method of drilled shafts. Transp. Geotech. 2026, 62, 102130. [Google Scholar] [CrossRef]
  23. Wang, J.; Wang, C.; Hu, Z. Response of a loaded pile in soft soils under one-dimensional nonlinear creep consolidation with non-Darcian flow and continuous drainage boundaries. Ocean Eng. 2026, 354, 124820. [Google Scholar] [CrossRef]
  24. Liang, R.; Yin, Z.-Y.; Yin, J.-H.; Wu, P.-C. Numerical analysis of time-dependent negative skin friction on pile in soft soils. Comput. Geotech. 2023, 155, 105218. [Google Scholar] [CrossRef]
  25. Wang, G.; Wang, Y.; Zhang, M.; Jiang, B.; Yang, J. Study on Negative Friction of Long Short Pile Foundations in Loess Regions Considering Immersion. Buildings 2026, 16, 3730. [Google Scholar] [CrossRef]
  26. Burland, J.B. On the compressibility and shear strength of natural clays. Géotechnique 1990, 40, 329–378. [Google Scholar] [CrossRef]
  27. Cotecchia, F.; Chandler, R.J. A general framework for the mechanical behaviour of clays. Géotechnique 2000, 50, 431–447. [Google Scholar] [CrossRef]
  28. Liu, M.D.; Carter, J.P. Virgin compression of structured soils. Géotechnique 1999, 49, 43–57. [Google Scholar] [CrossRef]
  29. Onitsuka, K.; Hong, Z.; Hara, Y.; Yoshitake, S. Interpretation of Oedometer Test Data for Natural Clays. Soils Found. 1995, 35, 61–70. [Google Scholar] [CrossRef]
  30. Liu, J.; Hu, S.; Liu, G.; Zhang, J.; Lu, Z. Study of Constitutive Models of Reconstituted Clay with High Initial Water Content. Sustainability 2023, 15, 12618. [Google Scholar] [CrossRef]
  31. García-Ros, G.; Alhama, I. Method to Determine the Constitutive Permeability Parameters of Non-Linear Consolidation Models by Means of the Oedometer Test. Mathematics 2020, 8, 2237. [Google Scholar] [CrossRef]
  32. Butterfield, R. An Improved Model of Soil Response to Load, Unload and Re-load Cycles in an Oedometer. Soils Found. 2011, 51, 253–263. [Google Scholar] [CrossRef]
  33. Tanaka, H. Consolidation Behavior of Natural Soils around pc Value—Long Term Consolidation Test. Soils Found. 2005, 45, 83–95. [Google Scholar] [CrossRef] [PubMed]
  34. Liu, Z.; Xia, Y.; Shi, M.; Zhang, J.; Zhu, X. Numerical Simulation and Experiment Study on the Characteristics of Non-Darcian Flow and Rheological Consolidation of Saturated Clay. Water 2019, 11, 1385. [Google Scholar] [CrossRef]
  35. Liu, Y.; Ma, R.; Zhu, Y.; Yi, X.; Satyanaga, A.; Dai, G.; Gao, P.; Zhai, Q. Oedometer Study Regarding the Consolidation Behavior of Nanjing Soft Clay. Appl. Sci. 2024, 14, 7339. [Google Scholar] [CrossRef]
  36. Kaewhanam, N.; Chaimoon, K. A Simplified Silty Sand Model. Appl. Sci. 2023, 13, 8241. [Google Scholar] [CrossRef]
  37. Phonchamni, N.; Chatwong, T.; Udomchai, A.; Sultornsanee, S.; Angkawisittpan, N.; Sangiamsak, N.; Kaewhanam, N. Refined Consolidation Settlement Calculation Based on the Oedometer Tests for Normally and Overconsolidated Clays. Appl. Sci. 2025, 15, 5777. [Google Scholar] [CrossRef]
  38. Chatwong, T.; Kaewhanam, N.; Kampala, A.; Eua-apiwatch, S.; Sultornsanee, S. AJOP-T: A High-Order Hardening Law for Continuous Teardrop Bounding Surface Plasticity. Mathematics 2026, 14, 2975. [Google Scholar] [CrossRef]
  39. Chaiduangsri, N.; Kaewhanam, N.; Chatwong, T.; Inthidech, S.; Kampala, A.; Eua-apiwatch, S.; Sultornsanee, S. Evaluating Compressibility Assumptions for Geological CO₂ Storage Using Linear and Nonlinear Compression Evidence. Preprints 2026, 2026101596, [Preprint; not peer reviewed]. [Google Scholar] [CrossRef]
  40. Gwak, D.-J.; Park, K.; Jo, B.-H.; Baek, S.-H. Interpretation of the Preconsolidation Stress in Soft Clay Using the One-Dimensional Consolidation Test. J. Mar. Sci. Eng. 2026, 14, 740. [Google Scholar] [CrossRef]
  41. Chalajour, S.; Blatz, J.A. Prediction of drag force on piles subjected to negative skin friction induced by bridge embankment construction based on measured field data. Transp. Geotech. 2025, 51, 101507. [Google Scholar] [CrossRef]
  42. Kania, J.G.; Sørensen, K.K.; Fellenius, B.H. The development of unit shaft resistance along driven piles in subsiding soil. Can. Geotech. J. 2024, 61, 1035–1050. [Google Scholar] [CrossRef]
  43. Su, C.; Pan, H.; Hou, Q.; Zhang, L.; Cao, J.; Wang, L.; Yuan, X. Correction of Compression Modulus of Deep Cohesive Soil and Settlement Calculation Based on Field Tests in the Haihe Alluvial Plain. Buildings 2026, 16, 3829. [Google Scholar] [CrossRef]
  44. Wan, X.; Doherty, J. From data to decision: combining Bayesian updating with a data-driven prior to forecast the settlement of embankments on soft soils. Can. Geotech. J. 2024, 61, 885–895. [Google Scholar] [CrossRef]
  45. Sargent, R.G. Verification and Validation of Simulation Models: An Advanced Tutorial. In Proceedings of the 2020 Winter Simulation Conference, Virtual Conference, 14–18 December 2020; pp. 16–29. [Google Scholar] [CrossRef]
  46. Indraratna, B.; Balasubramaniam, A.S.; Phamvan, P.; Wong, Y.K. Development of negative skin friction on driven piles in soft Bangkok clay. Can. Geotech. J. 1992, 29, 393–404. [Google Scholar] [CrossRef]
  47. Endo, M.; Minou, A.; Kawasaki, T.; Shibata, T. Negative Skin Friction Acting on Steel Pipe Pile in Clay. In Proceedings of the 7th International Conference on Soil Mechanics and Foundation Engineering, Mexico City, Mexico, 1969; Mexico City, Mexico; Vol. 2, pp. 85–92. Available online: https://www.issmge.org/uploads/publications/1/38/1969_02_0012.pdf (accessed on 18 October 2026).
  48. Blanchard, J.; Jana, A.; Coffman, R.; Stuedlein, A.; Budge, A. NCHRP Research Report 1112: Design of Piles for Downdrag, Database of Instrumented Static Load Test Data on Driven Piles. Version 2; DesignSafe-CI, 2025. [Google Scholar] [CrossRef]
  49. Fellenius, B.H.; Edvardsson, F.; Pettersson, J.; Sabattini, M.; Wallgren, J. Prediction, Testing, and Analysis of a 50 m Long Pile in Soft Marine Clay. DFI J. 2019, 13, 1–7. Available online: https://www.fellenius.net/papers/406%20Test%20and%20analysis%20of%20a%20long%20pile%20in%20soft%20marine%20clay.pdf (accessed on 18 October 2026). [CrossRef]
  50. Fellenius, B.H. Revisiting Tavenas (1971): Tests on Piles in Sand. DFI J. 2025, 19, 1–9. [Google Scholar] [CrossRef]
  51. Lin, H.; Chen, S.; Alqrinawi, H. Calculating Pile Downdrag: Experimental and Numerical Investigations. Report 20GTLSU10; Transportation Consortium of South-Central States, Louisiana State University. Baton Rouge, LA, USA, 2021. Available online: https://rosap.ntl.bts.gov/view/dot/61738 (accessed on 18 October 2026).
  52. Cao, F.; Ye, C.; Wu, Z.; Zhao, Z.; Sun, H. Settlement Calculation of Semi-Rigid Pile Composite Foundation on Ultra-Soft Soil under Embankment Load. Buildings 2024, 14, 1954. [Google Scholar] [CrossRef]
  53. Rong, X.; Li, M.; Liao, H.; Zhang, A.; Dang, T.; Li, H.; Wu, Z. Influence of Groundwater Level Rising on Mechanical Properties of Pile Foundations Under a Metro Depot in Loess Areas. Buildings 2025, 15, 1341. [Google Scholar] [CrossRef]
  54. Fellenius, B.H. A case history on use of wick drains and unsuccessful piled foundation. Keynote lecture, 31st Symposium of the Vancouver Geotechnical Society, Vancouver, BC, Canada, 2025; pp. 1–17. Available online: https://www.fellenius.net/papers/441%20Wickdrains%20and%20piling.%20A%20case%20history.pdf (accessed on 18 October 2026).
Figure 1. Full initial-loading fits and residuals for the three specimens. Markers are reconstructed source observations; curves use the frozen AJOP least-squares parameters. Reading bars and shaded ordinate bands are deterministic digitization allowances, not confidence intervals. Randers strain and residuals are expressed as percent and percentage points, respectively. Sources: [41,42]. Panels (a,d), (b,e), and (c,f) show Manitoba 11 m, Manitoba 23 m, and Randers, respectively.
Figure 1. Full initial-loading fits and residuals for the three specimens. Markers are reconstructed source observations; curves use the frozen AJOP least-squares parameters. Reading bars and shaded ordinate bands are deterministic digitization allowances, not confidence intervals. Randers strain and residuals are expressed as percent and percentage points, respectively. Sources: [41,42]. Panels (a,d), (b,e), and (c,f) show Manitoba 11 m, Manitoba 23 m, and Randers, respectively.
Preprints 239163 g001
Figure 2. Randers stress-window holdout. The first seven initial-loading markers calibrate the curve; the final two markers are withheld from that fit. Residuals retain the training/holdout distinction. The plotted reading band is ±0.3 percentage points, while the largest held-out least-squares error is 4.63 percentage points. Source observations: [42]. (a) Fit and held-out markers; (b) residuals.
Figure 2. Randers stress-window holdout. The first seven initial-loading markers calibrate the curve; the final two markers are withheld from that fit. Residuals retain the training/holdout distinction. The plotted reading band is ±0.3 percentage points, while the largest held-out least-squares error is 4.63 percentage points. Source observations: [42]. (a) Fit and held-out markers; (b) residuals.
Preprints 239163 g002
Figure 3. Analytical AJOP logarithmic slopes and observed adjacent secants. Tangents and secants are different quantities. Manitoba uses void-ratio slopes; Randers uses strain slopes. The high-stress Randers decrease challenges the nondecreasing-slope family over the plotted window. Finite-window secants do not identify global asymptotes. Source observations: [41,42]. (a) Manitoba 11 m; (b) Manitoba 23 m; (c) Randers.
Figure 3. Analytical AJOP logarithmic slopes and observed adjacent secants. Tangents and secants are different quantities. Manitoba uses void-ratio slopes; Randers uses strain slopes. The high-stress Randers decrease challenges the nondecreasing-slope family over the plotted window. Finite-window secants do not identify global asymptotes. Source observations: [41,42]. (a) Manitoba 11 m; (b) Manitoba 23 m; (c) Randers.
Preprints 239163 g003
Figure 4. Joint response decisions in selected synthetic examples: incompatible output targets, transfer-versus-compression response widths, laboratory interpolation sensitivity, and common-coefficient feasibility. Cases and scenario multipliers are numerical tests, not field datasets or probability distributions. Empty outer-envelope intersections denote a lack of certification; only the known-reference comparison establishes failure to match that particular nonlinear response. The laboratory panel uses reconstructed observations from [42]. (a) Case 100 feasible intervals; (b) response-width ratios; (c) interpolation effect; (d) Case 477 common interval.
Figure 4. Joint response decisions in selected synthetic examples: incompatible output targets, transfer-versus-compression response widths, laboratory interpolation sensitivity, and common-coefficient feasibility. Cases and scenario multipliers are numerical tests, not field datasets or probability distributions. Empty outer-envelope intersections denote a lack of certification; only the known-reference comparison establishes failure to match that particular nonlinear response. The laboratory panel uses reconstructed observations from [42]. (a) Case 100 feasible intervals; (b) response-width ratios; (c) interpolation effect; (d) Case 477 common interval.
Preprints 239163 g004
Figure 5. Bangkok measured-profile reconstruction and the fixed-shape scaling test. Force coordinates include explicitly identified head anchors; deep settlement overlaps are intervals rather than separate measured time series. The robust shape discrepancy is at 4 m; the 10 m reading intervals overlap. Reconstructed from [46]. (a) Soil-settlement profiles and scaling test; (b) T1 force profiles; (c) T2 force profiles.
Figure 5. Bangkok measured-profile reconstruction and the fixed-shape scaling test. Force coordinates include explicitly identified head anchors; deep settlement overlaps are intervals rather than separate measured time series. The robust shape discrepancy is at 4 m; the 10 m reading intervals overlap. Reconstructed from [46]. (a) Soil-settlement profiles and scaling test; (b) T1 force profiles; (c) T2 force profiles.
Preprints 239163 g005aPreprints 239163 g005b
Figure 6. Retrospective Bangkok day-25 calibration and day-265 transfer test. The prediction band spans only the selected deep-settlement scan with fitted transfer parameters frozen. It is not a complete uncertainty envelope. Withheld force observations were not used in calibration, but the exercise was retrospective. Source force and settlement charts: [46]. (a) T1; (b) T2.
Figure 6. Retrospective Bangkok day-25 calibration and day-265 transfer test. The prediction band spans only the selected deep-settlement scan with fitted transfer parameters frozen. It is not a complete uncertainty envelope. Withheld force observations were not used in calibration, but the exercise was retrospective. Source force and settlement charts: [46]. (a) T1; (b) T2.
Preprints 239163 g006
Figure 7. Six tabulated Haihe nominal-pressure–void-ratio curves and full-window comparator fits. Markers are published table entries. Panels (a)–(f) correspond to D2-18–D2-23 from one programme with unreported drainage and duration details. Source: [43].
Figure 7. Six tabulated Haihe nominal-pressure–void-ratio curves and full-window comparator fits. Markers are published table entries. Panels (a)–(f) correspond to D2-18–D2-23 from one programme with unreported drainage and duration details. Source: [43].
Preprints 239163 g007
Table 1. Evidence units and the questions they can support.
Table 1. Evidence units and the questions they can support.
Evidence Available material Role in this study Principal limit
Digitized compression 25 loading markers; 3 specimens; 2 programmes Curve fit, shape, stress-window transfer Digitized figures; no raw stage histories
Tabulated compression 66 points; 6 specimens; 1 Haihe programme Fit, blocked prediction, shape test Nominal pressure; duration and drainage unreported
Unloading/
reloading
12 Manitoba markers Branch and history diagnostic Excluded from initial-loading fits
Synthetic piles 500 frozen cases Joint response feasibility Selected model cases, not field frequencies
Bangkok monitoring 2 piles; 5 force-profile times Cross-stage transfer challenge Deep settlement and capacity history unresolved
Table 2. AJOP fitting errors: least squares (LS), root-mean-square error (RMSE), and the distinct minimax objective. Randers errors are percentage points (pp) of engineering strain.
Table 2. AJOP fitting errors: least squares (LS), root-mean-square error (RMSE), and the distinct minimax objective. Randers errors are percentage points (pp) of engineering strain.
Dataset n fitted LS RMSE LS max. Minimax max. Reading band
Manitoba 11 m 8 0.000577 e 0.000880 e 0.000689 e ±0.0015 e
Manitoba 23 m 8 0.002429 e 0.004586 e 0.003184 e ±0.0015 e
Randers full 9 0.6386 pp 1.0682 pp 1.0437 pp ±0.3000 pp
Randers first 7 7 0.1714 pp 0.3425 pp 0.2380 pp ±0.3000 pp
Table 3. Selected numerical decisions at 10% relative tolerance.
Table 3. Selected numerical decisions at 10% relative tolerance.
Case or test Response examined Result Interpretation
500 frozen cases Outer total-force and W envelopes 105 joint passes Head load enters the tolerance
Subset of 105 passes Switch total force to drag 29 certificates lost All 29 still match their synthetic reference
500 frozen cases Outer D and W envelope 76 joint passes Conditional envelope adequacy
Same 500 cases Synthetic-reference D and W 496 matches One reference curve only
Case 31 Outer D and W envelope Best error 5.172% A constant can suffice despite broad slope range
Case 100 Synthetic-reference D and W Best error 16.124% No common 10% constant in this model
Case 9 Outer D and W envelope Best error 17.205% Outer failure; synthetic reference match remains possible
Case 477 All 27 transfer scenarios Common interval exists Adequacy persists over the selected scenarios
Table 4. Haihe void-ratio RMSE. Full-window calibration uses 11 points; blocked calibration uses 9 points and evaluates the final 2. C, A and B denote constant logarithmic slope, generalized AJOP and constrained bilinear models, respectively. Values are dimensionless; smaller errors do not establish field validity.
Table 4. Haihe void-ratio RMSE. Full-window calibration uses 11 points; blocked calibration uses 9 points and evaluates the final 2. C, A and B denote constant logarithmic slope, generalized AJOP and constrained bilinear models, respectively. Values are dimensionless; smaller errors do not establish field validity.
Specimen Full C Full A Full B Held-out C Held-out A Held-out B
D2-18 0.007807 0.000913 0.002121 0.018001 0.005635 0.007181
D2-19 0.009220 0.000841 0.002181 0.019222 0.002526 0.007484
D2-20 0.010704 0.002501 0.002605 0.013161 0.009558 0.004668
D2-21 0.005411 0.000505 0.001269 0.012163 0.002361 0.003913
D2-22 0.002152 0.000769 0.000769 0.003869 0.001598 0.001598
D2-23 0.003437 0.000321 0.000767 0.006952 0.000877 0.002449
Table 5. Actions from the joint coefficient decision within the declared model and information class.
Table 5. Actions from the joint coefficient decision within the declared model and information class.
Decision Meaning Action
R* ≤ 1; common interval nonempty One coefficient meets both tolerances over the stated scenarios. Select from the common interval and report the tolerances and domain.
R* > 1 for an outer box The current envelope cannot certify the simplification. Improve relevant compression or transfer information; retain a conservative assessment meanwhile.
R* > 1 for a prescribed reference No constant in the stated domain meets both targets for that reference. Use a richer compression description or explicitly revise the modelling requirements.
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.
Copyright: This open access article is published under a Creative Commons CC BY 4.0 license, which permit the free download, distribution, and reuse, provided that the author and preprint are cited in any reuse.