Submitted:
29 December 2024
Posted:
31 December 2024
You are already at the latest version
Abstract
Continuous monitoring of drinking water quality is essential for safeguarding public health, particularly in densely populated urban areas like the National Capital Region (NCR) of Delhi. In this study, 47 water samples were randomly collected from various public sources across Delhi and its surrounding areas using a standardized sampling technique. An Arduino-based sensor system was employed to measure critical water quality parameters, including pH, total dissolved solids (TDS), and turbidity. While pH levels were consistently within the acceptable limits across all samples, approximately 14% of the samples exhibited elevated TDS and turbidity levels, raising concerns about potential contamination. In contrast, commercially packaged drinking water samples were found to have significantly lower TDS and turbidity levels, suggesting a higher level of quality control in packaged water compared to public sources. These findings emphasize the importance of continuous water quality monitoring to identify and mitigate potential health risks in real time. This study demonstrates the feasibility and effectiveness of Arduino-based systems as a cost-effective, scalable solution for real-time water quality assessment in urban environments. By leveraging sensor technology, this approach offers a practical means of ensuring safe drinking water in Delhi and similar densely populated regions.
Keywords:
1. Introduction
2. Design and Development
3. Samples Collection
4. Result and Discussion
5. Conclusions
Acknowledgement
References
- He, C.; Liu, Z.; Wu, J.; Pan, X.; Fang, Z.; Li, J.; Bryan, B.A. Future Global Urban Water Scarcity and Potential Solutions. Nat. Commun. 2021, 12, 4667. [Google Scholar] [CrossRef] [PubMed]
- Vörösmarty, C.J.; McIntyre, P.B.; Gessner, M.O.; Dudgeon, D.; Prusevich, A.; Green, P.; Glidden, S.; Bunn, S.E.; Sullivan, C.A.; Liermann, C.R.; et al. Global Threats to Human Water Security and River Biodiversity. Nature 2010, 467, 555–561. [Google Scholar] [CrossRef] [PubMed]
- Reid, A.J.; Carlson, A.K.; Creed, I.F.; Eliason, E.J.; Gell, P.A.; Johnson, P.T.J.; Kidd, K.A.; MacCormack, T.J.; Olden, J.D.; Ormerod, S.J. Emerging Threats and Persistent Conservation Challenges for Freshwater Biodiversity. Biol. Rev. 2019, 94, 849–873. [Google Scholar] [CrossRef] [PubMed]
- Akhtar, N.; Syakir Ishak, M.I.; Bhawani, S.A.; Umar, K. Various Natural and Anthropogenic Factors Responsible for Water Quality Degradation: A Review. Water 2021, 13, 2660. [Google Scholar] [CrossRef]
- WHO Water, Sanitation, Hygiene and Health: A Primer for Health Professionals. World Heal. Organ. 2019, 1–40.
- Kaur, B.J.; George, M.P.; Mishra, S. Groundwater Quality and Water Quality Index of Delhi City, India. 2014; 32, 865–871. [Google Scholar] [CrossRef]
- Bidhuri, S.; Khan, M.M.A. Assessment of Ground Water Quality of Central and Southeast Districts of NCT of Delhi. J. Geol. Soc. India 2020, 95, 95–103. [Google Scholar] [CrossRef]
- Gubbi, J.; Buyya, R.; Marusic, S.; Palaniswami, M. Internet of Things (IoT): A Vision, Architectural Elements, and Future Directions. Futur. Gener. Comput. Syst. 2013, 29, 1645–1660. [Google Scholar] [CrossRef]
- Khanh, Q.V.; Hoai, N.V.; Manh, L.D.; Le, A.N.; Jeon, G. Wireless Communication Technologies for IoT in 5G: Vision, Applications, and Challenges. Wirel. Commun. Mob. Comput. 2022, 2022, 3229294. [Google Scholar] [CrossRef]
- Geetha, S.; Gouthami, S. Internet of Things Enabled Real Time Water Quality Monitoring System. Smart Water 2016, 2, 1–19. [Google Scholar] [CrossRef]
- Adhikary, P.P.; Chandrasekharan, H.; Chakraborty, D.; Kamble, K. Assessment of Groundwater Pollution in West Delhi, India Using Geostatistical Approach. Environ. Monit. Assess. 2010, 167, 599–615. [Google Scholar] [CrossRef] [PubMed]
- Sarkar, A.; Ali, S.; Kumar, S.; Shekhar, S.; Rao, S.V.N. Groundwater Environment in Delhi, India. In Groundwater environment in Asian cities; Elsevier, 2016; pp. 77–108.
- Chatterjee, R.; Gupta, B.K.; Mohiddin, S.K.; Singh, P.N.; Shekhar, S.; Purohit, R. Dynamic Groundwater Resources of National Capital Territory, Delhi: Assessment, Development and Management Options. Environ. Earth Sci. 2009, 59, 669–686. [Google Scholar] [CrossRef]
- Kumar, A.; Biswas, R.; Modi, R.; Button, C. Place of Social, Cultural, and Ecological Water Values for Promoting Water Security in Delhi, India. Water (Switzerland) 2024, 16. [Google Scholar] [CrossRef]
- Pathak, S.; Jain, K.; Kumar, V.; Pant, R.P. Magnetic Fluid Based High Precision Temperature Sensor. IEEE Sens. J. 2017, 17, 2670–2675. [Google Scholar] [CrossRef]
- Singh, A.; Pathak, S.; Kumar, P.; Sharma, P.; Rathi, A.; Basheed, G.A.; Maurya, K.K.; Pant, R.P. Tuning the Magnetocrystalline Anisotropy and Spin Dynamics in CoxZn1-XFe2O4 (0 ≤ x ≤ 1) Nanoferrites. J. Magn. Magn. Mater. 2020, 493, 165737. [Google Scholar] [CrossRef]
- Kumar, P.; Pathak, S.; Singh, A.; Khanduri, H.; Basheed, G.A.; Wang, L.; Pant, R.P. Microwave Spin Resonance Investigation on the Effect of the Post-Processing Annealing of CoFe 2 O 4 Nanoparticles. Nanoscale Adv. 2020, 2, 1939–1948. [Google Scholar] [CrossRef] [PubMed]
- Singh, A.; Kumar, P.; Pathak, S.; Jain, K.; Garg, P.; Pant, M.; Mahapatro, A.K.; Rath, D.; Wang, L.; Kim, S.-K.; et al. A Threefold Increase in SAR Performance for Magnetic Hyperthermia by Compositional Tuning in Zinc-Substituted Iron Oxide Superparamagnetic Nanoparticles with Superior Biocompatibility. J. Alloys Compd. 2023, 968, 171868. [Google Scholar] [CrossRef]
- Singh, A.; Kumar, P.; Rajput, P.; Jain, K.; Pathak, S.; Puri, S.; Maurya, K.K.; Pant, R.P. Investigating the Impact of Zinc Ion Substitution on the Rheological Properties and Hyperthermia Potential of Cobalt Ferrite-Based Ferrofluids. Mater. Today Proc. 2023. [Google Scholar] [CrossRef]
- Singh, A.; Kumar, P.; Pathak, S.; Jain, K.; Garg, P.; Pant, M.; Mahapatro, A.K.; Singh, R.K.; Rajput, P.; Kim, S.-K.; et al. Tailored Nanoparticles for Magnetic Hyperthermia: Highly Stable Aqueous Dispersion of Mn-Substituted Magnetite Superparamagnetic Nanoparticles by Double Surfactant Coating for Improved Heating Efficiency. J. Alloys Compd. 2024, 976, 172999. [Google Scholar] [CrossRef]
- Bajaj, A.; Jamal, S.; Upadhyay, A.; Kumar, K.; Singh, M. Water Problems and Challenges: A Case Study of Delhi NCR. J. Water L. Use Manag. 17.
- Jain, S.K. Population Rise and Growing Water Scarcity in India–Revised Estimates and Required Initiatives. Curr. Sci. 2011, 101, 271–276. [Google Scholar]
- BUREAU OF INDIAN STANDARDS Product Manual for Drinking Water According To Is 10500 : 2012. 2020, 158, 626.e1-626.e2.






| Sample ID | Location | Type of sample | Category of Sample | District | State/UT | Type of locality | Longitude | Latitude | |||
| S1 | Sec 29 Ind Area HUDA Panipat | Public Water booth for drinking | Drinking water | Panipat | Haryana | City | 76.988 | 29.375 | |||
| S2 | Sec 29 Ind Area HUDA Panipat | Public Water booth for drinking | Drinking water | Panipat | Haryana | City | 77 | 29.357 | |||
| S3 | Ahuja Panjabi Dahaba, Toll Plaza Panipat | Normal Water for customer/guest | Drinking water | Panipat | Haryana | City | 76.97 | 29.436 | |||
| S4 | Petrol Pump Sc 29 Panipat | Public drinking water | Drinking water | Panipat | Haryana | City | 76.982 | 29.377 | |||
| S5 | Shiva Dhaba, Murthal | Normal Water for customer/guest | Drinking water | Sonepat | Haryana | City | 77.065 | 29.055 | |||
| S6 | Pappu Dhaba, Shankar Road, Delhi | Normal Water for customer/guest | Drinking water | Central District | NCT of Delhi | City | 77.181 | 28.637 | |||
| S7 | Shanakr Road, Hand pump | Hand pump | Ground water | Central District | NCT of Delhi | City | 77.181 | 28.637 | |||
| S8 | Umed garh, Village, sonepat | Drinking water Govt supply | Drinking water | Sonepat | Haryana | City | 77.111 | 29.113 | |||
| S9 | ARIES Guest House | Drinking water for guest | Drinking water | Nainital | Uttrakhand | Village (Hill) | 79.4583 | 29.36 | |||
| S10 | ARIES Securty gate | Hannd pump for village | Ground water | Nainital | Uttrakhand | Village (Hill) | 79.4609 | 29.3586 | |||
| S11 | Gappu Check Post | Hand pump for village | Ground water | Nainital | Uttrakhand | Village (Foot hill) | 79.3477 | 29.2852 | |||
| S12 | Singh Toursir Punjab Dhaba | Normal Water for customer/guest | Drinking water | Rampur | Uttar Pradesh | Village | 79.093 | 29.1128 | |||
| S13 | Baba Ilam Chowk, Rampur | Public Water booth for drinking | Drinking water | Rampur | Uttar Pradesh | City | 79.01634 | 28.8154 | |||
| S14 | DIET Gate, Rampur | Public Water booth for drinking | Drinking water | Rampur | Uttar Pradesh | City | 79.0148 | 28.7966 | |||
| S15 | Gajrola Bus stand | Hand pump | Ground water | J.P. Nagar | Uttar Pradesh | City | 78.247 | 28.8284 | |||
| S16 | Green Park, Delhi | Candle based RO | RO | South District | NCT of Delhi | City | 77.202 | 28.558 | |||
| S17 | Hastal Village | Drinking water | DJB Supply | West District | NCT of Delhi | City | 77.048 | 28.637 | |||
| S18 | Hastal Village | Drinking water | DJB Supply | West District | NCT of Delhi | City | 77.048 | 28.637 | |||
| S19 | JRF Hostel, RO | Drinking water | RO | Central District | NCT of Delhi | City | 77.17497 | 28.63464 | |||
| S20 | Crescent Appt. Dwarka | House hold supply water | Drinking water | South west District | NCT of Delhi | City | 77.046051 | 28.59214 | |||
| S21 | Farrukh Nagar Gurgaon | Drinking water | RO | Gurugram | Haryana | City | 77.026344. | 28.457523 | |||
| S22 | Farrukh Nagar Gurgaon | House hold supply water | Tap water | Gurugram | Haryana | City | 77.026344. | 28.457523 | |||
| S23 | Farrukh Nagar Gurgaon | House hold supply water | Hand pump | Gurugram | Haryana | City | 77.026344. | 28.457523 | |||
| S24 | Farrukh Nagar Gurgaon | Drinking water | Tap water | Gurugram | Haryana | City | 77.026344. | 28.457523 | |||
| S25 | Ashoka Road, Connaugt place | Drinking water | Drinking water | Central District | NCT of Delhi | City | 77.2185 | 28.6236 | |||
| S26 | Janak Puri | House hold supply water | Drinking water | West District | NCT of Delhi | City | 77.088 | 28.621 | |||
| S27 | Akhada Pandit wali gali | Drinking water Govt supply | Drinking water | West District | NCT of Delhi | City | 77.163 | 28.621 | |||
| S28 | Uttam Nagar | Drinking water Govt supply | RO | West District | NCT of Delhi | City | 77.054 | 28.619 | |||
| S29 | Faridkot | Drinking water | RO | Punjab | Panjab | City | |||||
| S30 | Ramesh Nagar | House hold supply water | Drinking water | West District | NCT of Delhi | City | 77.132 | 28.65 | |||
| S31 | Rajendra Nagar | House hold supply water | Drinking water | West District | NCT of Delhi | City | 77.175 | 28.634 | |||
| S32 | Patel Nagar | House hold supply water | Drinking water | West District | NCT of Delhi | City | 77.164 | 28.655 | |||
| S33 | Ramesh Nagar | Drinking water | RO | West District | NCT of Delhi | City | |||||
| S34 | NDLS, PF #16, railway station | Public Water booth for drinking | Drinking water | Central District | NCT of Delhi | City | 77.22 | 28.643 | |||
| S35 | NDLS, PF #10, railway station | Public Water booth for drinking | Drinking water | Central District | NCT of Delhi | City | |||||
| S36 | ISBT Kashmiri gate | Public Water booth for drinking | Tap water | Central District | NCT of Delhi | City | 77.231 | 28.668 | |||
| S37 | Delhi Secretariat (ITO) | Drinking water | RO | East District | NCT of Delhi | City | 77.25 | 28.63 | |||
| S38 | DPCC | Drinking water | tap water | Central District | NCT of Delhi | City | 77.229 | 28.668 | |||
| S39 | GTB nagar | Drinking water | tap water | North District | NCT of Delhi | City | 77.193 | 28.553 | |||
| S40 | Delhi university | Drinking water | RO | North District | NCT of Delhi | City | |||||
| S41 | Sharpur Gate | Drinking water | RO | South District | NCT of Delhi | City | |||||
| S42 | Hauz khaus | Drinking water | RO | South District | NCT of Delhi | City | |||||
| S43 | Patel Nagar | Drinking water | Supply | West District | NCT of Delhi | City | |||||
| S44 | Geeta Colony, Krishna Nagar | Drinking water | Supply | East District | NCT of Delhi | City | |||||
| S45 | Dashghra | Drinking water | supply | West District | NCT of Delhi | City | |||||
| S46 | Dashghra | Drinking water | RO | West District | NCT of Delhi | City | 77.203 | 28.547 | |||
| S47 | Kalka Ji | Drinking water | RO | South District | NCT of Delhi | City | 77.263 | 28.538 | |||
| Commercial packaged drinking water | |||||||||||
| S48 | Supreme Jal | ||||||||||
| S49 | Aquafina | ||||||||||
| S50 | Rail neer | ||||||||||
| S51 | Bisleri | ||||||||||
| S52 | Kinley | ||||||||||
| S53 | Bailey | ||||||||||
| Sample ID | pH | TDS (mg/l) | Turbidity (NTU) | Temp (C) | ||||||
| SR | AL | PL | AR | AL | PL | SR | AL | PL | ||
| S1 | 8.6 | 6.5-8.5 | No relaxation | 660 | 500 | 2000 | 1.5 | 1 | 5 | 27.9 |
| S2 | 8.4 | 6.5-8.5 | No relaxation | 267 | 500 | 2000 | 0.4 | 1 | 5 | 28 |
| S3 | 8 | 6.5-8.5 | No relaxation | 275 | 500 | 2000 | 0.4 | 1 | 5 | 27.9 |
| S4 | 8.2 | 6.5-8.5 | No relaxation | 647 | 500 | 2000 | 1.2 | 1 | 5 | 27.8 |
| S5 | 7.6 | 6.5-8.5 | No relaxation | 64 | 500 | 2000 | 0 | 1 | 5 | 28.1 |
| S6 | 8.2 | 6.5-8.5 | No relaxation | 170 | 500 | 2000 | 0.1 | 1 | 5 | 28 |
| S7 | 8.4 | 6.5-8.5 | No relaxation | 360 | 500 | 2000 | 0.5 | 1 | 5 | 27.9 |
| S8 | 7.7 | 6.5-8.5 | No relaxation | 654 | 500 | 2000 | 2 | 1 | 5 | 27.9 |
| S9 | 8.2 | 6.5-8.5 | No relaxation | 100 | 500 | 2000 | 0.5 | 1 | 5 | 28 |
| S10 | 7.1 | 6.5-8.5 | No relaxation | 136 | 500 | 2000 | 0.6 | 1 | 5 | 28 |
| S11 | 7.8 | 6.5-8.5 | No relaxation | 285 | 500 | 2000 | 0.8 | 1 | 5 | 28 |
| S12 | 8 | 6.5-8.5 | No relaxation | 350 | 500 | 2000 | 0.8 | 1 | 5 | 28 |
| S13 | 8.1 | 6.5-8.5 | No relaxation | 208 | 500 | 2000 | 0.7 | 1 | 5 | 27.9 |
| S14 | 7.9 | 6.5-8.5 | No relaxation | 251 | 500 | 2000 | 0.7 | 1 | 5 | 27.9 |
| S15 | 8.2 | 6.5-8.5 | No relaxation | 190 | 500 | 2000 | 0.4 | 1 | 5 | 27.9 |
| S16 | 8.4 | 6.5-8.5 | No relaxation | 113 | 500 | 2000 | 0.25 | 1 | 5 | 28 |
| S17 | 7.9 | 6.5-8.5 | No relaxation | 144 | 500 | 2000 | 0.3 | 1 | 5 | 28 |
| S18 | 8 | 6.5-8.5 | No relaxation | 145 | 500 | 2000 | 0.3 | 1 | 5 | 28.2 |
| S19 | 7.4 | 6.5-8.5 | No relaxation | 49 | 500 | 2000 | 0.2 | 1 | 5 | 28.2 |
| S20 | 8.1 | 6.5-8.5 | No relaxation | 480 | 500 | 2000 | 0.3 | 1 | 5 | 28 |
| S21 | 8.2 | 6.5-8.5 | No relaxation | 40 | 500 | 2000 | 0.1 | 1 | 5 | 30 |
| S22 | 8 | 6.5-8.5 | No relaxation | 205 | 500 | 2000 | 0.8 | 1 | 5 | 29.8 |
| S23 | 7.8 | 6.5-8.5 | No relaxation | 104 | 500 | 2000 | 0.5 | 1 | 5 | 29.8 |
| S24 | 7 | 6.5-8.5 | No relaxation | 126 | 500 | 2000 | 0.1 | 1 | 5 | 30 |
| S25 | 8 | 6.5-8.5 | No relaxation | 135 | 500 | 2000 | 0.5 | 1 | 5 | 31 |
| S26 | 8.6 | 6.5-8.5 | No relaxation | 106 | 500 | 2000 | 0.3 | 1 | 5 | 25.8 |
| S27 | 8 | 6.5-8.5 | No relaxation | 94 | 500 | 2000 | 0 | 1 | 5 | 26 |
| S28 | 8.1 | 6.5-8.5 | No relaxation | 173 | 500 | 2000 | 0.3 | 1 | 5 | 26.1 |
| S29 | 7.2 | 6.5-8.5 | No relaxation | 42 | 500 | 2000 | 0 | 1 | 5 | 26 |
| S30 | 8.1 | 6.5-8.5 | No relaxation | 153 | 500 | 2000 | 0.8 | 1 | 5 | 25.9 |
| S31 | 7.9 | 6.5-8.5 | No relaxation | 140 | 500 | 2000 | 0.6 | 1 | 5 | 25.8 |
| S32 | 7.6 | 6.5-8.5 | No relaxation | 120 | 500 | 2000 | 0.5 | 1 | 5 | 25.9 |
| S33 | 7 | 6.5-8.5 | No relaxation | 76 | 500 | 2000 | 0 | 1 | 5 | 26 |
| S34 | 8.4 | 6.5-8.5 | No relaxation | 659 | 500 | 2000 | 2.2 | 1 | 5 | 26 |
| S35 | 8.4 | 6.5-8.5 | No relaxation | 696 | 500 | 2000 | 2.4 | 1 | 5 | 26.1 |
| S36 | 8.2 | 6.5-8.5 | No relaxation | 608 | 500 | 2000 | 2 | 1 | 5 | 26 |
| S37 | 6.7 | 6.5-8.5 | No relaxation | 25 | 500 | 2000 | 0.1 | 1 | 5 | 26 |
| S38 | 7.5 | 6.5-8.5 | No relaxation | 100 | 500 | 2000 | 0.5 | 1 | 5 | 30 |
| S39 | 6.8 | 6.5-8.5 | No relaxation | 16 | 500 | 2000 | 0 | 1 | 5 | 30 |
| S40 | 7 | 6.5-8.5 | No relaxation | 23 | 500 | 2000 | 0 | 1 | 5 | 29.8 |
| S41 | 6.5 | 6.5-8.5 | No relaxation | 5 | 500 | 2000 | 0.1 | 1 | 5 | 29.9 |
| S42 | 6.9 | 6.5-8.5 | No relaxation | 26 | 500 | 2000 | 0.2 | 1 | 5 | 30 |
| S43 | 8 | 6.5-8.5 | No relaxation | 132 | 500 | 2000 | 0.5 | 1 | 5 | 29.9 |
| S44 | 8.5 | 6.5-8.5 | No relaxation | 774 | 500 | 2000 | 3 | 1 | 5 | 29.8 |
| S45 | 7 | 6.5-8.5 | No relaxation | 60 | 500 | 2000 | 0 | 1 | 5 | 29.8 |
| S46 | 6.6 | 6.5-8.5 | No relaxation | 20 | 500 | 2000 | 0.1 | 1 | 5 | 25.9 |
| S47 | 6.8 | 6.5-8.5 | No relaxation | 17 | 500 | 2000 | 0.2 | 1 | 5 | 26 |
| Commercial packaged drinking water | ||||||||||
| 1 | 6 | 6.5-8.5 | No relaxation | 39 | 500 | 2000 | 0 | 1 | 5 | 26 |
| 2 | 7 | 6.5-8.5 | No relaxation | 40 | 500 | 2000 | 0 | 1 | 5 | 26.2 |
| 3 | 7 | 6.5-8.5 | No relaxation | 38 | 500 | 2000 | 0 | 1 | 5 | 28 |
| 4 | 6.9 | 6.5-8.5 | No relaxation | 35 | 500 | 2000 | 0.1 | 1 | 5 | 29 |
| 5 | 7 | 6.5-8.5 | No relaxation | 30 | 500 | 2000 | 0.1 | 1 | 5 | 29 |
| 6 | 7 | 6.5-8.5 | No relaxation | 45 | 500 | 2000 | 0 | 1 | 5 | 29.1 |
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |