Preprint Article Version 1 Preserved in Portico This version is not peer-reviewed

Dentinal Hypersensitivity Treatment with 1064 nm and 980 nm Diode Laser

Version 1 : Received: 28 October 2023 / Approved: 30 October 2023 / Online: 30 October 2023 (09:54:51 CET)

How to cite: El Mobadder, M.; Nammour, S. Dentinal Hypersensitivity Treatment with 1064 nm and 980 nm Diode Laser. Preprints 2023, 2023101854. https://doi.org/10.20944/preprints202310.1854.v1 El Mobadder, M.; Nammour, S. Dentinal Hypersensitivity Treatment with 1064 nm and 980 nm Diode Laser. Preprints 2023, 2023101854. https://doi.org/10.20944/preprints202310.1854.v1

Abstract

Dentinal Hypersensitivity (DH), a prevalent oral health issue affecting approximately one-third of adults. In this six-months retrospective study, a comparison was made to assess the effectiveness of two diode lasers with different wavelengths (980 nm and 1064 nm) in the treatment of tooth affected by DH. In total, 160 patients were divided into two treatment groups: one receiving treatment with a 980 nm diode laser (n=80) and the other with a 1064 nm diode laser (n=80). Pain was assessed using the Visual Analogue Scale (VAS) at baseline, immediately post-treatment, and at 3- and 6-months follow-up. Both groups followed the same treatment protocol, involving the application of a graphite paste to the exposed dentin before laser irradiation. Both lasers operated at an output power of 0.5 W in continuous and non-contact mode, with a 320 µm spot size. A significant reduction in mean VAS scores at all follow-up intervals compared to baseline was noted. 980 nm group had mean VAS scores of 7.9, 2.36, 2.31, and 2.38, while the 1064 nm group had scores of 8.01, 1.01, 1.16, and 1.13 at baseline, immediately post-treatment, and at 3 and 6 months, respectively. At all times of follow-up, the 1064 nm wavelengths showed a statistically significant reduction in mean values of VAS compared to the 980 nm. The findings may inform future research on optimizing laser-based treatments for DH.

Keywords

laser dentistry; restorative dentistry; dentinal tubular occlusion; diode laser; dentinal hypersensibility; pain management

Subject

Medicine and Pharmacology, Dentistry and Oral Surgery

Comments (0)

We encourage comments and feedback from a broad range of readers. See criteria for comments and our Diversity statement.

Leave a public comment
Send a private comment to the author(s)
* All users must log in before leaving a comment
Views 0
Downloads 0
Comments 0
Metrics 0


×
Alerts
Notify me about updates to this article or when a peer-reviewed version is published.
We use cookies on our website to ensure you get the best experience.
Read more about our cookies here.