Influence of the Volute Design Parameters on the Flow Phenomena and Performance of the Centrifugal Compressor

Version 1 : Received: 18 February 2022 / Approved: 21 February 2022 / Online: 21 February 2022 (14:52:08 CET)

How to cite: hassan, A.S.; Hadidi,, H.; Tharwan, M. Influence of the Volute Design Parameters on the Flow Phenomena and Performance of the Centrifugal Compressor. Preprints 2022, 2022020256. https://doi.org/10.20944/preprints202202.0256.v1 hassan, A.S.; Hadidi,, H.; Tharwan, M. Influence of the Volute Design Parameters on the Flow Phenomena and Performance of the Centrifugal Compressor. Preprints 2022, 2022020256. https://doi.org/10.20944/preprints202202.0256.v1

Abstract

Influence of the volute design parameters on the stable operating range and the performance of a centrifugal compressor was investigated experimentally for the following design conditions. The volute casing surface roughness was changed from 0 to 200 µm in five steps and tested. The axial distance between the casing and the diffuser cascades (clearance) was varied in five steps as C/b2 = 1.2, 2.4%, 3.6%, 4.8%, and 6% relative to the impeller exit width. The radial distance from the impeller blade exit to the diffuser vane inlet in (vaneless space radius) in six steps as C/r2 = 1.03, 1.05, 1.07, 1.09, 1.11, and 1. 13 relatives to the rotor outlet radius. The volute outlet geometry of a symmetric and tangent with different area ratios from 0.4 to 0.9. Finally, the compressor has been tested experimentally with different pinched vaned diffuser distances relative to the impeller exit width of bp/b2 =1, 0.98, 0.96, 0.94, 0.92, and 0.9. These testes were carried at different compressor operating conditions, and the time variations of the static pressure were recorded using five high-frequency response pressure transducers. A hot-wire anemometer is used to measure the compressor flow rate. The rotating stall and surge at the vaneless zone after the impeller exit can be detected by analyzing the fluctuations of pressure signals and the power spectrum density by using the Fast Fourier Transformation analysis. The experimental results indicated that the compressor with volute casing surface roughness of 100mm gives about 10.9% enhancements in the stable operating and 1% in pressure rise coefficient. The best axial distance between the diffuser vanes and the casing is 2.4% of the impeller blade height and the compressor in this design gives about 12.4% improvements in the stable working range. The compressor with radial vaneless distance of 1.056 gives improvements of about 16.6% in the surge margin, 2% in the pressure recovery and 4% in pressure rise coefficients. The compressor with a pinched diffuser of b/bp of 0.98 gives an improvement of 20.8% in surge point.

Keywords

Casing treatment; Surge margin; Rotating stall; surface roughness; flow instability

Subject

Engineering, Mechanical Engineering

Comments (0)

We encourage comments and feedback from a broad range of readers. See criteria for comments and our Diversity statement.

Leave a public comment
Send a private comment to the author(s)
* All users must log in before leaving a comment
Views 0
Downloads 0
Comments 0
Metrics 0


×
Alerts
Notify me about updates to this article or when a peer-reviewed version is published.
We use cookies on our website to ensure you get the best experience.
Read more about our cookies here.