Blue-LED Calibration on DOAS System to Measure Nitrogen Dioxide Emission Compared with USEPA Method 7B Standard

Version 1 : Received: 28 November 2021 / Approved: 29 November 2021 / Online: 29 November 2021 (11:59:30 CET)

How to cite: Fatkhurrahman, J.A.; Sari, I.R.J. Blue-LED Calibration on DOAS System to Measure Nitrogen Dioxide Emission Compared with USEPA Method 7B Standard. Preprints 2021, 2021110527. https://doi.org/10.20944/preprints202111.0527.v1 Fatkhurrahman, J.A.; Sari, I.R.J. Blue-LED Calibration on DOAS System to Measure Nitrogen Dioxide Emission Compared with USEPA Method 7B Standard. Preprints 2021, 2021110527. https://doi.org/10.20944/preprints202111.0527.v1

Abstract

Air polution level measurement sometime needs tricky instrumentation, costly, and use chemical reagent that could bad impact to environment, it also time consuming for analysis. In other hand, air polution level measurement, include nitrogen dioxide (NO2) needs accuracy, rapid and environment friendly for its analysis and measurement. Differential Optical Absorption Spectroscopy (DOAS) develop as spectrum measurements both UV and visible, transmitted by specific canal using absorption Lambert Beer’s Law principal. On this basic method, NO2 measurement needs light source with 330 – 500 nm wavelength, it is possible to use cheap blue-LED for this measurement. This research intends to calibrate prototype instrumentation for measuring NO2 by DOAS based using Blue-LED (375 nm) passed in continual gas container. NO2 emission simulated in laboratory scale by reacting copper (Cu) with nitric acid (HNO3) result NO2 gas formation. Blue-LED spectrum analysed by compact CCD Spectrometer for its absorbance spectrum, then calibrated with NO2 measurement using USEPA Method 7B standard that is commonly used in testing laboratory as standard method for NO2 measurement. It has good corelation between spectrum absorbance in CCD Spectrometer to USEPA Method 7B with more than 95% linierity. As rapidity of this measurement and shown good accuracy, more development for this method could carry fast, accurate, cheap, also environmentally friendly method for NO2 measurement.

Keywords

DOAS; Blue-LED; USEPA Method 7B; CCD Spectrometer

Subject

Biology and Life Sciences, Biochemistry and Molecular Biology

Comments (0)

We encourage comments and feedback from a broad range of readers. See criteria for comments and our Diversity statement.

Leave a public comment
Send a private comment to the author(s)
* All users must log in before leaving a comment
Views 0
Downloads 0
Comments 0
Metrics 0


×
Alerts
Notify me about updates to this article or when a peer-reviewed version is published.
We use cookies on our website to ensure you get the best experience.
Read more about our cookies here.