A position sensing glove, called SmartScan, that creates a 3D virtual model of a real object is presented. The data from the glove is processed by a volume minimization algorithm to validate the position sensor data. This allows only data from the object’s surface to be retained. The data validation algorithm allows the user to progressively improve an image by repeatedly moving their hand over the object. In addition, the user can choose their own balance between feature resolution and invalid data rejection. The SmartScan glove is tested on a foot model and is shown to be robust against motion artifacts, and has a mean accuracy of 2.9 mm (compared to a 3D model generated from optical imaging) without calibration.
Keywords: 
ankle-foot orthosis; position sensors; smart glove; 3D modeling
Subject: 
Engineering  -   Electrical and Electronic Engineering