Preprint Article Version 1 Preserved in Portico This version is not peer-reviewed

Preparation and Description of Potentiometric Electrode for the Limitation of Sulbutamol Sulphate

Version 1 : Received: 6 June 2019 / Approved: 7 June 2019 / Online: 7 June 2019 (13:49:13 CEST)

How to cite: Majeed, M.; Motaweq, Z. Preparation and Description of Potentiometric Electrode for the Limitation of Sulbutamol Sulphate. Preprints 2019, 2019060061. https://doi.org/10.20944/preprints201906.0061.v1 Majeed, M.; Motaweq, Z. Preparation and Description of Potentiometric Electrode for the Limitation of Sulbutamol Sulphate. Preprints 2019, 2019060061. https://doi.org/10.20944/preprints201906.0061.v1

Abstract

A new sulbatamol sulphate SBS membrane electrode was prepared that utilizing for its determination ; depend on the forming of the association complex ion of sulbatamol sulphate by the phosphotungstate counter anion deposed in poly vinyl chloride PVC polymer, by use a (Di-n- Octyl Phenyl Phthalate)(Dopp) as the plastizier substance, in membrane.The features properties as well as the behavior of it .The new electrode have been elaborated. The concentrations of medicine by utillizing This sensor show a fast, stable, near-Nernstian response in the range (1x10-1-1x10-6) mol/ L were determined with correlation coefficient of about (r = 0.9991) and with of a relative standard about 0.416 additionally deviation relative standard error of 1.710 %.pot The nernast linearity slop was founded and it is equal to 28.9 mV/decade and the detection limit was 4.1 x 10-6 mol/ L.The electrode selectivity coefficient Ki,j was calculated, in the existence of several interferences cations with confirmed medicine solutions. It was found the pH range response is in the range of (3 -7), with the response time of (30 – 116) sec. for various concentrations at room temperture , the lifetime for electrode was found to be more than 21 days. The electrode was successfully used for potentiometric limitation of sulbatamol sulphate in several pharmaceutical drugs by using direct potentiometry.

Keywords

new, sulbatamol sulphate, membrane electrode , utilizing for determination

Subject

Chemistry and Materials Science, Analytical Chemistry

Comments (0)

We encourage comments and feedback from a broad range of readers. See criteria for comments and our Diversity statement.

Leave a public comment
Send a private comment to the author(s)
* All users must log in before leaving a comment
Views 0
Downloads 0
Comments 0
Metrics 0


×
Alerts
Notify me about updates to this article or when a peer-reviewed version is published.
We use cookies on our website to ensure you get the best experience.
Read more about our cookies here.