Preprint
Article

This version is not peer-reviewed.

Bioimpedance and Bone Fracture Detection: A State of the Art

Submitted:

30 April 2019

Posted:

03 May 2019

You are already at the latest version

Abstract
Bioimpedance measurements are used increasingly in health applications because bioelectric parameters have been associated with anatomical and physiological properties, thus enabling to distinguish medical conditions. For bone fracture diagnostics, nevertheless, there is no established non-invasive method. Ex vivo studies and In vivo bioimpedance procedures, both invasive and non-invasive, on mammalians long bones are associated with promising results. In this work, out of a total of 568 papers, we reviewd 59 articles that mention long bone integrity by electric properties, be it Bioimpedance Analysis, Electrical Impedance Spectroscopy or Electrical Impedance Tomography. The papers are described in three sections, “Ex vivo measurements”, “In vivo invasive measurements” and “In vivo non-invasive measurements”. This review allows to establish the basics to planning the development of new technology to detect bone fracture via bioimpedance measurements.
Keywords: 
;  ;  ;  ;  ;  
Copyright: This open access article is published under a Creative Commons CC BY 4.0 license, which permit the free download, distribution, and reuse, provided that the author and preprint are cited in any reuse.